Loading...
312 NE 101 St (13)Notary as My Co FEES: PERMIT APPROVED: Zoning Mechanical PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date */6 Job Address 3/1 /VeV Si Tax Folio 1/ 32 (X,,O 2() Legal Description /OIJ /OW 1 — See 39 / / S Historically Designated: Yes No Owner/Lessee / Tenant Me/24 My Master Permit # 6a Owner's Address ?/? /mac /0/ Phone 79 - 7 qq SL/ Contracting Co. 23t1 r M C�.0 /� a r � Address 8. 8 3 Qualifier 3/a).,1411-6f,././ K ss# phoneq.)y q /1®5/J State # Municipal # " 1 /63 2 / O / Competency #C1O B OO( 6 Ins. Co. , .. / 0 ()C,/ S , f Architect/Engineer Bonding Company Mortgagor Permit Type (circle eoBUILDING LECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Pcittwe tfiP ocol 7 cVoe C / Square Ft. Estimated Cost (value) 1 J6 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF CO I ' CEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, will be performed to meet the standards of all laws regulating construction in this jurisdiction. PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all ork 11 be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the '.; ; b.' r i �TT3> ' IE K. HOGLUND ` � MY COMMISSION # CC 512735 EXPIRES: November 29, 1999 if , g ". Bonded Thru Notary Public Underwriters RADON Building Address Address Address d on the attached addendum (if applicable). I certify that all work understand that separate permits are required for ELECTRICAL of Contracto Owner- Builder Date 7 - LM No as to o �o .. ' ..h A. Burton _BONDED THRU Notary Contractor o � u X13 " 4 0 . : . _ Date My Commission Expires.q•'.. 'r ; ;" '' s ter, c c 783832 NOV 21, 2002 � ", "� A T L ffl;c GONDING CQ, INC. C.C.F. , A0 NOTARY • BOND Electrical TOTAL DUE G D Plumbing Structural Engineer Mt I KUrUU IAN UAUt LAJUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI, FLOR 33130 -1963 (305) 375-2901 FAX (305) 375 -2908 Clopay Corporation 312 Walnut St., Suite 1600 Cincinnati OH 45202 .acceptance No.:97- 0122.02 (Revises No.: 95- 0821.02) Expires:08 /21/00 CONDITIONS BUILDING CODE COMMITTEE Approved: 08/21/97 -1- PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Your application for Product Approval of: 24 GA. Sectional Door 9' Wide under Chapter 8 of the Metropolitan Dade County Code governing the use of Altemate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Applicant, along with Clopay Building Products Co. drawing # 101702 -24, last revision on 07/08/97, signed and sealed by M. W. Westerfield P.E. (For complete listing, see Section 7 of this Notice of Acceptance) has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Raul Rodriguez Product Control Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County. Florida under the conditions set forth above. Dircctor Building Code Compliance Dept. Metropolitan Dade County Internet mail address: postmaster @buildingcodeonline.com Homepage: http : / /www.buildingcodeonllne.com ,Clopay' Corporation ACCEPTANCE NO: 97- 0122.02 APPROVED : AUG 2 1 1997 EXPIRES : AUG 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1.0 DESCRIPTION: This approves sectional door 9" wide x 8' -0" through 6' -6 "" high made out of steel, drawing quality Grade 28,000 KSI (ASTM A525), galvanized coating of G60 (ASTM A525) and finished with baked on polyester coating. The door shall be constructed and reinforced as detailed in the approved drawing #101702-24 2.0 USE: This door is approved for a maximum design pressure of +42PSF and -48PSF and its use is restricted to this pressure. The door passed the impact and cyclic test; therefore it does not require hurricane protection devices. The door shall meet the burglary security requirement of section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not included in this approval) shall be certified by Underwriters Laboratories or other recognized agency. ido Font, PE, Sr. Product Control Examiner Product Control Division Track Skin End Stile Center Stile End Hinge Center Hinge Horizontal Reinforcement Shape Frequency 16 GA 24 GA 20 GA 20 GA 14 GA 18 GA 21/2" x 20 GA U 1/3 Section 2 /Other Section ,Clopay' Corporation ACCEPTANCE NO: 97- 0122.02 APPROVED : AUG 2 1 1997 EXPIRES : AUG 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1.0 DESCRIPTION: This approves sectional door 9" wide x 8' -0" through 6' -6 "" high made out of steel, drawing quality Grade 28,000 KSI (ASTM A525), galvanized coating of G60 (ASTM A525) and finished with baked on polyester coating. The door shall be constructed and reinforced as detailed in the approved drawing #101702-24 2.0 USE: This door is approved for a maximum design pressure of +42PSF and -48PSF and its use is restricted to this pressure. The door passed the impact and cyclic test; therefore it does not require hurricane protection devices. The door shall meet the burglary security requirement of section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not included in this approval) shall be certified by Underwriters Laboratories or other recognized agency. ido Font, PE, Sr. Product Control Examiner Product Control Division Clopav Corporation ACCEPTANCE NO: 97- 0122.02 APPROVED : AUG 2 1 1997 EXPIRES : AUG 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 3.0 INSTALLATION: The door shall be installed as shown on Drawing #101702-24. Wood in contact with concrete or cement shall be treated with an approved preservative as set forth in paragraph 2913.2(a)1 or shall be of a durable species as defined in subparagraph 2913.2(a)6(aa) of the South Florida Building Code. Installation of 2" x 6" wood jamb requires a' 'A" x 3%" ITW tapcon and 1" 0 x 1/16" thick washer @ 8" from bottom & 16" o/c with a minimum embedment of 1 %" into 2000 PSI (minimum) concrete or grout filled concrete block. Or 3/8" x 4" Rawl Lok/bolt and 1" 0 x 1/16" thick washer @ 8" from bottom and 24" o/c with a minimum embedment of 1 V2 into 2000 PSI (minimum) concrete or grout filled concrete block. Installation of track requires a 5/16" x 1'V2 "wood lag screw at each track and flag bracket @ as shown on Drawing #101702 -24 with a minimum embedment of 1- 1/16" into 0.55 SG Southern Yellow Pine PT 2" x 6" wood jamb. 4.0 CONDITIONS OF USE: .Application for Building permit shall be accompanied by duplicate prints of the approved Drawing # 1 0 1 702 -24 bearing the approval stamp, Notice of Acceptance number and date by the Dade County Product Control Section along with computations prepared by a qualified Florida Professional Engineer or Architect verifying the adequacy of the door at each site. The shop drawing shall bear the signature of the Architect or Engineer with the following statement: The supporting structure has been designed for the forces shown on the approved manufacturer's drawing ". Application for building permit for replacement doors shall be accompanied by duplicate prints of the approved Drawing 10 1702 -24 bearing the approval stamp, Notice of Acceptance number and date by the Dade County Product Control Section. Also the building official must be satisfied that the proposed installation meet the use of Section 2 above. -2a- andido Font, PE, Sr. Product Control Examiner Product Control Division Clopav Corporation ACCEPTANCE NO: 97- 0122.02 APPROVED : AUG 2 1 197 EXPIRES : AUG 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 5.0 LIMITATIONS: This approval requires the manufacturer to do testing of all coils used to fabricate door panels under this Notice of Acceptance. A minimum of 2 specimens shall be cut from each coil and tensile tested (according to ASTM E -8) by a Dade County approved laboratory selected and paid by the manufacturer. Every 3 months, four times a year, the manufacturer shall mail to this office: a copy of the test reports with confirmation that the specimens were selected from coils at the manufacturer's production facilities and a notarized statement from the manufacturer that only coils with a yield strength of 28,000 PSI or more shall be used to make door panels for Dade County under this Notice of Acceptance. 6.0 IDENTIFICATION: All approved products shall be permanently labeled with the manufacturer's name, city, state and the following statement: "Dade County Product Control Approved ". 7.0 EVIDENCE SUBMITTED: Test Report CTL 4986 B ATL :111201 - 96 Calculations Mark W. Westerfield Drawing Clopay B.P., Co. Test Date ASTM E -8 12/16/96 PA 201, 202 & 203 11/13/97 Date Signature 01/10/97 M. W. Westerfield, PE Number 101702 - 24 -2b- Last Revision 07/08/97 Signature R. Patel, PE W. Mehner, PE Signature M.W. Westerfield, PE an ido Font, PE, Sr. Product Control Examiner Product Control Division Clopav Corporation Items 10, 11 .S 12 listed below only apply to glazed products EXPIRES NOTICE OF ACCEPTANCE STANDARD CONDITIONS ACCEPTANCE NO : 97- 0122.02 APPROVED : AUG 21 1997 in 2 1 2000 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer, who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering professions. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. .Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies. shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2 (b) and this last page 3. 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section 11. The spacing of fasteners at windowsills shall be as indicated in Section 4 of this Notice of Acceptance. The spacing of fasteners in all other parts of the frame shall be as indicated in Section 4 of this Notice of Acceptance. but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the same size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. 12. Hardware for all windows and doors shall conform to Security and Forccd Entry Prevention. Chapter 36 of the South Florida Building Code. Candido Font, PE. Sr. Product Control Examiner Product Control Division END OF THIS ACCEPTANCE -3-