301 NE 101 St (3)Legal Description 30/ 4/F: /0/ 0 517 /1/J /,5L 4/( 5/i' 4 5 J' )W
SEC- / , I 7 .f wI/ /,o7 /y okrt3f
Owner / Lessee / Tenant 1/1/ Master Permit # 1 03 5 !.3
Owner's Address f Phone
Contracting Co. //> • c_ - A//M 5 COA /f NO Address /7/7 k/ 7 /41 Al/]e/f`- 33/37
Qualifier /7ti iea D r^ . 25/94/:1,05 ss# 5 3 T 7/ 4 /?
State # Municipal # 9037 Competency # Ins.Co.
Architect /Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTION 17,ei' ('F /0o' _
as
Square Ft. Estimated Cost(value) / �J O
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO
SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S. AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I
authorize the above -named contractor to do the work stated.
Signa
Date:
2 - an • • -
alie.ed)9V6iViZa
Notary as to Owner and /or CondocA c ytfi SEAL.
My Commission Expires: C LMS
NOTARY PUBLIC STATE OF FLORIDA
COMMISSION NO. CC339927
MY COMMISSION EXP. JAN. 20,1998
** * * * * * * * * *
PEES: PERMIT
APPROVED:
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
^ 30//-1/E /
( 0
Job Address d G4/v /. CO/, lr Tax Folio/ l / ,� o 6 - D/3'5-1
_President Signatur� f Contractor or Owner- Builder
Date: 6 -
a4.Gtei W66')taJ
RADON C.C.F.
Fire
Zoning Buildin
/50
Mechanical Plumbing
actoQFkt MBVTAUer
MARCIA HILMS
MARY PUBLIC STATE OF FLORIDA
COMMISSION NO. CC339927
MY COMMISSION EXP. JAN. 20,1998
* * * * * **
Notary as to Contr
My Commission Expi
NOTARY TOTAL DUE '7 el.
Other
Electrical
Engineering
ME�DADE METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Clopay Corporation
312 Walnut St.
Cincinnati,
OH 45202
Your application for Product Approval of:
24 ga. Galvanized Steel Sectional Garage Door 9' wide
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by:
applicant. For listing see section 7 of this Notice of Acceptance.
has been recommended for acceptance by the Building Code Compliance office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions
on page 3.
This approval shall not be valid after the expiration date stated below. The Office of Code Compliance
reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for
quality control testing. If this product or material fails to perform in the approved manner, the Code
Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The
applicant shall re- evaluate this product or material should any ammendments to the South Florida Building
Code be enacted affecting this product or material. The Building Code Compliance Office reserves the
the right to revoke this approval, if it is determined by the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code. The expense of
such testing will be incurred by the manufacturer.
Acceptance No.:95- 0821.02 (Revises No.: 95- 0317.01)
BUILDING CODE COMPLIANCE OFFICE
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
PRODUCT CONTROL SECTION
(305) 375 -2902
FAX (305) 372 -6339
Raul Rodl•iguez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
Expires:07 /25/97
This application for Product Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Department and approved by the Building Code Committee to be used in Dade
County, Florida under the conditions set forth above.
Approved: 11 /02/95 -1-
Director
Building Code Compliance Dept.
Metropolitan Dade County
Clopav Corporation ACCEPTANCE No.: 95- 0821.02
APPROVED : Pl0V 0 2 1995
EXPIRES : JUL 2 5 1997
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
1.0 DESCRIPTION:
2.0 USE:
This approves sectional door 9' -0" wide x 6' -6" through 8' -0" high made out of steel, lock
forming quality (ASTM A527), a yield strength of 30,000 psi, a galvanized coating of G60
(ASTM A525) and finished with baked on polyester enamel. The door shall be constructed and
reinforced as detailed in the approved drawing 4101182 pages 1 & 2.
This approval includes 4 models which are the same door with the following difference:
Characteristic
Flush Panel
Smooth Texture
Wood Grain Texture
Wood Grain Texture & Painted
Model
78
91
93 or 83
94 or 84
This Door is approved for a maximum design pressure of +46psf & -48 psf and its use is
restricted to this pressure. The door passed the impact and cyclic test, therefore it does not
require hurricane protection devices. The door shall meet the burglary security requirement of
section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not
included in this approval) shall be certified by Underwriters Laboratories or other recognized
agency.
Candido Font, PE Plans Examiner
Product Control Division
RAM
SKIN
END
STILE
CENTER
STILE
END
HINGE
CENTER
HINGE
HORIZONTAL REINFORCEMENT
SHAPE FREQUENCY
1 2G.
24G.
18G
20G
14G
14G
20G U 1 /Section
Clopav Corporation ACCEPTANCE No.: 95- 0821.02
APPROVED : Pl0V 0 2 1995
EXPIRES : JUL 2 5 1997
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
1.0 DESCRIPTION:
2.0 USE:
This approves sectional door 9' -0" wide x 6' -6" through 8' -0" high made out of steel, lock
forming quality (ASTM A527), a yield strength of 30,000 psi, a galvanized coating of G60
(ASTM A525) and finished with baked on polyester enamel. The door shall be constructed and
reinforced as detailed in the approved drawing 4101182 pages 1 & 2.
This approval includes 4 models which are the same door with the following difference:
Characteristic
Flush Panel
Smooth Texture
Wood Grain Texture
Wood Grain Texture & Painted
Model
78
91
93 or 83
94 or 84
This Door is approved for a maximum design pressure of +46psf & -48 psf and its use is
restricted to this pressure. The door passed the impact and cyclic test, therefore it does not
require hurricane protection devices. The door shall meet the burglary security requirement of
section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not
included in this approval) shall be certified by Underwriters Laboratories or other recognized
agency.
Candido Font, PE Plans Examiner
Product Control Division
Clopav Corporation ACCEPTANCE No.: 95- 0821.02
APPROVED : M0V 0 2 1995
EXPIRES : JUL 2 5 1997
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
3.0 INSTALLATION:
The door shall be installed as shown on drawing #101182 pages 1 & 2. Wood in contact with
concrete or cement shall be treated with an approved preservative as set forth in paragraph
2913.2(a)1 or shall be of a durable species as defined in subparagraph 2913.2(a)6(aa) of the
South Florida Building Code. Installation of 2" x 6" wood jamb requires a 1/4" tapcon and 1".0
x 1/16" thick washer @ 12" o/c with a minimum embedment of 1 -1/2 into 3000 psi (minimum)
concrete or into 2000 psi grout filled concrete block. Installation of track requires a 5/16 x 1 1/2
lag screw per bracket (5 brackets minimum) with a minimum embedment of 1 3/8 into PT
Wood Jamb.
4.0 CONDITIONS OF USE:
Application for Building Permit shall be accompanied by duplicate prints of the approved
drawing's #101182 pages 1 & 2 bearing the approval stamp, Notice of Acceptance Number and
date by the Dade County Product Control Section along with computations prepared by a
qualified Florida Professional Engineer or Architect verifying the adequacy of the door at each
site. The shopdrawing shall bear the signature of the architect or engineer with the following
statement "The supporting structure has been designed for the forces on the approved
manufacturer's drawing."
Application for Building Permit for replacement doors shall be accompanied by duplicate prints
of the approved drawing #101182 pages 1 & 2 bearing the approval stamp, Notice of Acceptance
Number and date by the Dade County Product Control Section. Also the building official must
be satisfied that the proposed installation meets the use of Section 2 above.
5.0 LIMITATIONS:
This approval requires the manufacturer to do testing of all coils used to fabricate door panels
under this Notice of Acceptance. A minimum of 2 specimens shall be cut from each coil and
tensile tested (according to ASTM E -8) by a Dade County approved laboratory selected and paid
-2a-
Candido Font, PE Plans Examiner
Product Control Division
Clopav Corporation ACCEPTANCE No.: 95- 0821.02
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
by the manufacturer. Every 3 months, four times a year, the manufacturer shall mail to this
office: a copy of the test reports with confirmation that the specimens were selected from coils at
the manufacturer's production facilities and a notarized statement from the manufacturer that
only coils with a yield strength of 30,000 psi or more shall be used to make door panels for Dade
County under this Notice of Acceptance.
6.0 IDENTIFICATION:
All approved products shall be permanently labeled with the manufacturer's name, city, state and
the following statement: Dade County Product Control Approved ".
7.0 EVIDENCE SUBMITTED:
Test Reports
HETI 94 -47
Date
4/15/94
Calculations Date
Al Farooq Corp. 5/5/94
Drawing Number
Clopay B.P.Co. 101182
Drawing Ref. Signature
101182 pages 1 & 2 A. Vigar, P.E.
Signature
A.,.Farooq, P.E.
Last Revision
9/95
-2b-
APPROVED
EXPIRES
: NOV 0 9 1995
: JUL 2 5 1997
Signature
H.W. Westerfield
Candido Font, PE Plans Examiner
Product Control Division
Cl�oa_y Cor oration
ACCEPTANCE NO.:
-3-
APPROVED
EXPIRES
•
•
•
•
95- 0821.02
NOV 0 9 1995
' JUL 2 5 1997
NOTICE OF ACCEPTANCE STANDARD CONDITIONS
1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the
original submitted documentation, including test supporting data, engineering documents, are no older than eight (8)
years.
2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the
following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions
of this Acceptance.
3. Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of this product and
the product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved;
c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the
correct installation of the product;
d) The engineer who originally prepared, signed and sealed the required documentation initially submitted ,
is no longer practicing the engineering profession.
4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be
cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a
revision application with appropriate fee) and granted by this office.
5. Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other
purposes.
6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration
date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall
be done in its entirety.
7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to
the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The
copies need not be resealed by the engineer.
8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance.
9. This Acceptance contains pages I, 2, 2(a) through 2(b) and this last page 3.
Items 10. 11 & 12 listed below only apply to glazed products
10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For
multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section.
11 The spacing of fasteners at window sills shall be as tested. The spacing of fasteners in all other parts of the frame,
shall be as tested, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6"
from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the same size as the
one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. See section four (4) of this
approval for sizes of fasteners used in testing.
12. Hardware for all windows and doors shall conform to Security and Forced Entry Pre , Chapter 36 of the
South Florida Building Code.
Candido Font, P.E. Plans Examiner
Product Control Division
END OF THIS ACCEPTANCE