467 NE 100 StiA
Date 8 Job Address 467 N. E.100 Streket Tax Folio
< Gr S.
Legal Description
Owner/Lessee / Tenant OWNER Master Permit #
Owier'sAddress467 N.E. 100 Street Miami Shores,FL.33138 Phone (305)759-9778
Contracting Co. Address
Qualifier SS# Phone
State # Municipal # Competency # Ins. Co.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
Series
WORK DESCRIPTION 300 True Colonial Single Hung Window.
Square Ft. 26 4
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
None
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Signature of owner and/or Condo President Date
Notary as to Owner and/or Condo President Date
My Commission Expires:
FEES: PERMIT �� , 0 RADON
APPROVED:
Zoning Building
Mechanical Plumbing
Historically Designated: Yes No
Estimated Cost (value) $3.000. oo
of Contractor Owner- Builder
LOT22 BLK90 AMDPLOF Miami Shores SEC4PB15-
14.
(
dto
No): as to C actor or B
/ / Commission Expire u My commission CC439004
Expires Mar 01. 1999
v! Bonded by HAI
f OF 10 8 00- 422-1555
Date
C.C.F. eb NOTARY BOND
TOTAL DUE 4/,
Electrical
Engineering
AO -n4D>:
PRODUCT CONTROL NO
Cury -A -Tech Corporation
930 W. 23 Street
Hialeah
Acceptance No.:97- 0930.02
Expires:09 /30/98
Approved:11 /20/97
Your application for Product Approval of:
Series 300 True Colonial Single Hung Window
under Chapter 8 of.the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by:
Applicant (For listing, see section 8 of this Notice of Acceptance.)
has been recommended for acceptance by the Building Code Compliance office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions
on page 3.
This approval shall not be valid after the expiration date stated below. The Office of Code Compliance
reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for
quality control testing. If this product or material fails to perform in the approved manner, the Code
Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The
applicant shall re- evaluate this product or material should any ammendments to the South Florida Building
Code be enacted affecting this product or material. The Building Code Compliance Office reserves the
the right to revoke this approval, if it is determined by the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code. The expense of
such testing will be incurred by the manufacturer.
Raul Rodriguez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building.
Code Compliance Department and approved by the Building. Code Committee to be used in Dade
County, Florida under the conditions set forth above.
Internet mail address: postmaster@c buildingcodeoniine.com
11.
METROPOLITAN DADE COUNTY, FLORIDA
fv1ETRO -DACE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET, SUITE 1603
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
PRODUCT CONTROL DIVISION
(305) 375 -2902
FAX (305) 372 -6339
cries ganger,
Director
Building Code Compliance Dept.
Metropolitan Dade County
Homepage: http : / /www.buiidingcodeonline.com
Curv-A -Tech Corporation
NOTICE OF ACCE ' ANCE: SPECIFIC CONDITIONS
INSTALLATION:
4.1 Screws and Method of Attachment
4.1.1 Installation into Wood:
SILL Three #10 x 1" FH CP SMS, loc ed at 4" from ends and the third in the center
HEADER: ,Same as sill.
JAMBS : Six #10 x 1" FH CP SMS, loca - d at 4" from each end and at 4" on each side of meeting
rails center line, max. spacing of to exceed 24" o.c.
ote: Please see note #11. Page 3
Limit shun space to a maximum of 1/ .
4.3 ttachments of sub -bucks shall b- i esigned by the Architect or Engineer of Records and must be in
compli ••• ce with the South Flori s - : uilding Code.
4.4 Fastene - • . own Notice of Acceptance and must be made of stainless steel or have
adequate protection against corrosion, per DIN 50018. Aluminum contacting metals not considered
compatible shall be properly protected.
5. IDENTIFICATION
5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Dade County Product Control Approved ".
6. USE
6.1 Application for building permit shall be accompanied by two copies of the following:
6.1.1 This Notice of Acceptance. -
6.1.2 Completely dimensioned drawing showing size and location, including height above grade
of opening to receive window, mean roof height, length and width of building.
6.2 The Building Official shall ensure the adequacy of window to meet the pressure requirement of the
opening in which it is to be installed.
6.3 This document renews Notice of Acceptance No. 93- 1101.02 dated 12/06/93.
6.4 Note: The installation of this unit will require a hurricane protective system.
- 2b
ACCEPTANCE No.: 97- 0930.02
APPROVED : Ei 2 0 1997
EXPIRES : September 30. 1998
a,01.1.4
Manu Perez, P.E., Product C
Produ ontrol Division
1 Examiner
tr.Ji
AIR INFILTRATION @ 1.57 PSF
(ASTM E283)
WATER RESISTANCE (PSF) no leakage
(with and without screen)
UNIFORM STATIC PRESSURE FULL TEST
POSITIVE ASTM E330 10 Sec.
UNIFORM STATIC PRESSURE FULL TEST
E330 10 Sec.
NEGATIVE ASTM
FORCED -ENTRY RESISTANCE (FER)
AAMA 1302.5 -76
Pressure Rating (Positive)
Design
Pressure Rating (Negative)
Design
Cury -A -Tech Corporation
7. TESTS PERFORMED
7.1 TESTS: RESULTS:
LOAD
LOAD
2c -
ACCEPTANCE No.: 97- 0930.02
APPROVED
: NO120 1997
EXPIRES : September 30, 1998
NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS
TEST LOADS
0.29 CFM /FT
MTL -15737
+83 PSF
MTL -15737
_ +68.0 PSF
MTL -1 5737
-68.0 PSF
MTL -15737
SATISFACTORY
MTL -15737
DESIGN LOADS
+55.33 PSF
MTL -15737
+45.3 PSF
MTL -15737
-45.3 PSF
MTL -157"
45.3 PSF
-453 PSF
Manue Perez, P.E., Product C
Produc " ontrol Division
of Examiner
METRO -DADE
PRODUCT CONTROL NO y' c >: i . . • ACCEPTANCE
Curv-A -Tech Corporation
930 W. 23 Street
Hialeah
Acceptance No.: 95- 1219.03
Expires:03/28 /99
FL 33010
Approved: 03/28/96 -1-
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
SUITE 1603
METRO DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
INTERNET: mdcc01@shadow.net
PRODUCT CONTROL SECTION
(305) 375 -2902
FAX (305) 372 -6339
Your application for Product Approval of:
Aluminum Tube Mullions
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by:
Applicant, along with Drawing No. M95 -19A, Sheets 1 thru 3 of 3. (For listing, see
Section 8 of this Notice of Acceptance)
This approval shall not be valid after the expiration date stated below. The Office of Code Compliance
reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for
quality control testing. If this product or material fails to perform in the approved manner, the Code
Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The
applicant shall re- evaluate this product or material should any ammendments to the South Florida Building
Code be enacted affecting this product or material. The Building Code Compliance Office reserves the
the right to revoke this approval, if it is determined by the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code. The expense of •
such testing will be incurred by the manufacturer.
Raul Ro& guez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Department and approved by the Building Code Committee to be used in Dade
County, Florida under the conditions set forth above.
Director
Building Code Compliance Dept.
Metropolitan Dade County
ACCEPTANCE No.: 95 1219.03
APPROVED
EXPIRES
NOTICE OF ACCE •TA
4. IN ALLATION:
4.1 Vertical or Horizontal Applications:
WA 2 8 1996
M 2 8 1 9 9 9
5. IDENTIFICATION •
5.1 Each mullion shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Dade County Product Control Approved ".
- 2a -
4.1.1 Anchor Type A
Two 2" x 2" x 1/8" x 2 -5/8" long alumin clip angles (one on each interior side of the tube)
secured at each end of the mullion (to g 4 clip angles) with one leg, using two #14 SMS, two per
angle, spaced 2 " apart and the other g anchored to a 2x wood buck using one #14 SMS x 1 -1/4"
embed or with one 3/16" x 1 -3/4" apcon (1 per angle) directly into a precast concrete sill with a
minimum.embedment of 1 -1/ ' , as shown on Section "Anchor Type "A ", Drawing No. M95 -19A,
Sheet 3 of 3, bearing the D e County Product Control approval stamp.
4.1.2 Anchor T,
Two 2" x 2" x x 2-5/8" long aluminum clip angles (one on each interior side of the tube)
secur h end of the mullion (totaling 4 clip angles) with one leg, using two #14 SMS, two per
angle, spaced 2 " apart and the other leg anchored to a 2x wood buck using two per angle #14 SMS x
1 -1/2" min. embed spaced 2" apart minimum, as shown on Section "Anchor Type "B ", Drawing No.
M95 -19A, Sheet 3 of 3, bearing the Dade County Product Control approval stamp.
4.1.3 Anchor Type C •
Two 2" x 2" x 1/8" x 3 -5/8" long aluminum clip angles (one on each interior side of the tube)
secured at each end of the mullion (totaling 4 clip angles) with one leg, using three #14 SMS, three
per angle, spaced 1 -1/2" apart and the other leg anchored (with wood block notched out) directly
into concrete or to a concrete filled block with two 1/4" x 1 -3/4" Tapcon (2 per angle) with a
minimum embedment of 1-1/4", as shown on Section "Anchor Type "C ", Drawing No. M95 -19A,
Sheet 3 of 3, bearing the Dade County Product Control approval stamp.
4.2 For anchoring requirements of each window installation, please see Section 4 of each window's
individual Notice of Acceptance.
4.3 Attachments of sub -bucks shall be designed by the Architect or Engineer of Records and must be in
compliance with the South Florida Building Code.
4.4 Fasteners must have their own Notice of Acceptance and must be made of stainless steel or have
adequate protection against corrosion, per DIN 50018. Aluminum contacting metals rn* considered
compatible shall be properly protected.
azatif
Manuel(rez, P.E. Plans FQminer II
Product Control Division