277 NE 101 St (12)ENGINEER SEAL WINDOWS 8500 NW 64 Street Miami, Fl 33166 (305) 418-8787 ph (305) 418-8700 fax (888) 448 -4848 toll free http://www.stormproof.us AND DOOR WIND PRESSURE AS PER ASCE 7 -02 H < 60 OWNER: CHRIS ANTONOUPOLOS 277 NW 101 ST MIAMI SHORES FL 33138 MEAN ROOF HEIGHT, h HEIGHT ABOVE GROUND LEVEL, z BASIC WIND SPEED, V = 18 ft 10 ft 146 mph VELOCITY PRESSURE EXPOSURE COEFFICIENT FOR h, Kz = VELOCITY PRESSURE EXPOSURE COEFFICIENT FOR z, Kz = ENCLOSED BUILDING, THEN Gcpi = +1- 0.18 INPUT DATA: 0.882 VELOCITY PRESSURE, qh = 48.14 Ib /ft^2 0.849 VELOCITY PRESSURE, qz = 46.32 Ib /ft^2 TOPOGRAPHIC FACTOR, Kzt = 1.00 WIND DIRECTIONALITY FACTOR, Kd = 1.00 EXPOSURE CATEGORY = C IMPORTANCE FACTOR, I = 1.00 MARK WIDTH (In) HEIGHT (In) A (SF) ZONE Gcp+ Gcp - P+ (PSF) P- (PSF) A Al B C C1 D E F G 37 37 54 37 37 20 20 165 54 51 51 39 39 39 26 39 59 51 13.10 13.10 14.63 10.02 10.02 3.61 5.42 67.60 19.13 4 4 4 4 4 4 4 4 4 0.98 0.98 0.97 1.00 1.00 1.00 1.00 0.85 0.95 -1.08 -1.08 -1.07 -1.10 -1.10 -1.10 -1.10 -0.95 -1.05 54.0 54.0 53.6 55.0 55.0 55.0 55.0 48.2 52.7 VICENTE FRANCO P.E. SEP 2 5 2006 LIC # 62531 -60.6 -60.6 -60.2 -61.6 -61.6 -61.6 -61.6 -54.6 -59.2 Single Hung Casement Single Hung Single Hung Casement Single Hung Single Hung Sliding Glass Door Single Hung ENGINEER NAME AND SIGNATURE DATE i 4. ep . . ,X4Q-- a a • 1 A 44:1 t ,;0114(1. • , 1110i ujoll!j , , dit*.g lo t it444#44, , 1, -- - 46. 41. 4 a • / .446 >14 1 W - • 7 ^ isoe•,F - •• — 1F /2 e a4ez-J -- ameaoldlonormionsarmod • in; ova: 6'`y�-- -fie ri,