Loading...
SHUTTERSDate 5/ 2 9' 9 R Job Address 2 4 6 NE 10 i 5A reed Tax Folio H 3 2 °G 01 4 c?,C) M%ftM■ S Legal Description L k 7 C 1 /2. Lo j- ° o i 1C 3d- Historically Designated: Yes No f Owner/lce /Tent 01:1nh Rk Owner's Address e Phone 36 A 2SZ7 67/o Contracting Co. I)/ t/lES ! F / - 2S1 /Li M !mac( M ' Address 7576 Id -o WOE 0 A5 -- Qualifier di � , " TjA�� SS# Phone - bz Z668S State # Municipal # Competency # 4 0 /WZ Ins. Co. //US - Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION ' L i , Square Ft. /�J tft FEES: PERMIT APPROVED: Zoning Mechanical PERMIT APPLICATION FOR MIAMI SHORES VILLAGE I � Notary as to Owner- , .... � � , •.. My Commission E . ires: Co t 6" • Notary Public-State of Ror!da My Commission Expires JUN 15. 1990 COMM. # CC 472770 G12l9q RADON C.C.F. Estimated Cost (value) Master Permit # 44 93 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. 4k0 Signature of Contractor or Owner -Buil ' Date Notary as to Contras My Commission E r Tres: (P' (FAog f` fl Rout Notary Public-Vote of Ronda My Commission Expires JUN 15,1 COMM. • CC 472770 NOTARY Electrical BOND TOTAL DUE 'S129/99 ate Plumbing Structural Engineer M MIAMI - DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING PRODUCT CONTROL NOTICE OF ACCEPTANCE MetalTech, Inc. CONTRACTOR LICENSING SECTION 7635 West 2nd Court (305) 375 -2527 FAX (305) 375 -2558 Hialeah FL 33014 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375 -2902 FAX (305) 372 -6339 20 ga. Galvanized Steel Storm Panels under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 99-0217.06 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE Expires:04 /04/2000 This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved: 04/22 /1999 Internet mail address: postmaster ©bui ldingcodeonline.com BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 rancisco Quintana, R.A. Director 1 of 3 Miami -Dade County Building Code Compliance Office Homepage: bttp : / /www.buildiagcodeonline.com MetalTech, Inc. ACCEPTANCE No. : 99- 0217.06 APPROVED APR 2 2 1999 EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 04/04/2000 1. SCOPE This renews the Notice of Acceptance No. 95- 1220.03, which was issued on April 4, 1996. It approves a 20 gauge galvanized steel storm panels shutter, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami - Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter .23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION This 20 gauge galvanized steel storm panels shutter and its components shall be constructed in strict compliance with the following documents: Drawing No. 95015, titled "20 Ga. ", prepared by Ramms Engineering, Inc., dated October 1, 1995, sheets 1 through 6 of 6, signed and sealed by Robert S. Monsour, P.E., bearing the Miami -Dade County Product Control Approval and renewal stamps with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS All permanent set components, included but not limited to embedded anchor bolts, threaded cones, metal shields, headers and sills, must be protected against corrosion, contamination and damage at all times. 4. INSTALLATION This 20 gauge galvanized steel storm panels shutter and its components shall be installed in strict compliance with the approved drawings. 5. LABELING Each panel shall bear a permanent label with the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. /i/(ti- Helmy A. Mar, P. E. - Product Control Examiner Product Control Division 2 of 3 MetalTech, Inc. ACCEPTANCE No.: 99- 0217.06 APPROVED APR 2 2 1999 EXPIRES 04/04/2000 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the _ statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer, who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer needs not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE 3 of 3 Helmy A. Nfa�kar, P.E. - Product Control Examiner Product Control Division ED WORt � _ <: A.7 • �. i m 1N11:. 111M Ampy Manufacturers of Window Enclosure Systems, Insulated Roof and Wall Systems DATE: 6 ' il` J • PI Atm / 4 7 DEAR: ( BUILDING DEPARTMENT ) We are the Dade County Notice of Acceptance Holder for : J I FT M ETALIiCH,INC ESTI957 Weatherwall Division SHUTTER PRODUCT APPROVAL AUTHORIZATION FORM ACCORDION SHUTTER ACCEPTANCE NO. 95- 1122.03 .060 ALUM. STORM PANELS ACCEPTANCE NO. 95- 0130.08 18ga STEEL STORM PANELS ACCEPTANCE NO. 95- 0314.04 20ga STEEL STORM PANELS ACCEPTANCE NO. 95- 1220.03 SLIMLINE ACC. SHUTTER . ACCEPTANCE NO. 96-1126.10 This letter authorizes YQTS S /f5 74L M )0tkA4 to use our above named product at (CONTRACTOR / OWNER BUILDER ) the following job site. Sincerely, abek ( JOB OWNER'S NAME ) ( JOB ADDRESS) 44411 f (CITY , STATE & ZIP) • 7635 West Second Court/Hialeah, Florida 33014 -4334 U.S.A. Phone: (305) 823- 2323/Toll Free: (800) 432- 5180 /FAX: (800) 432 -1685 3 oo oft 617-L- S-fogy\ 'Ptiliot=z-_s 1 r14Y ZS [7s�sl x !9 x 37 J Ik c X x 2 ■ DESIGN WIND LOADS IN P.S.F. CLASS ONE BUILDING 1 10 M.P.H FASTEST MILE WIND SPEED COMPUES WITH ANSI /ASCE 7.88 (4) INTERIOR ZONE MAXIMUM CONDITIONS TRIBUTARY AREA IN SOUARE FEET GRADE 0 -10 20 50 100 200 500 1000 .1.5 -1.43 -1.34 .1.27 .1.19 .1.1 -1.1 15' 0.8 47.81 45.90 43.44 41.53 39.34 36.88 36.88 20' 0.87 51.99 49.92 47.24 45.16 42.78 40.11 40.11 25' 0.93 55.58 53.36 50.50 48.28 45.74 42.88 42.88 30' 0.98 58.57 56.23 53.21 50.87 48.19 45.18 45.18 40' 1.06 63.35 60.82 57.56 55.02 52.13 48.87 48.87 50' 1.13 67.53 64.83 61.36 58.66 55.57 52.10 52.10 60' 1.19 71.12 68.27 64.62 61.77 58.52 54.86 54.86 ABOVE GRADE 15' 0.8 20' 0.87 25' 0.93 30' 0.98 40' 1.06 50' 1.13 60' 1.19 (5) END ZONE MAXIMUM CONDITIONS TRIBUTARY AREA IN SOUARE FEET 0.10 20 50 100 200 500 1000 •2 .1.875 .1.625 -1.5 -1.375 .1.1 .1.1 61.47 58.06 51.23 47.81 44.40 36.88 36.88 66.85 63.14 55.71 51.99 48.28 40.11 40.11 71.46 67.49 59.55 55.58 51.61 42.88 42.88 75.30 71.12 62.75 58.57 54.39 45.18 45.18 81.45 76.93 67.88 63.35 58.83 48.87 48.87 86.83 82.01 72.36 67.53 62.71 52.10 52.10 91.44 86.36 76.20 71.12 66.04 54.86 54.86 Notation: a: 10% of minimum width or 0.4h, whichever is smaller, but not less than either 4% of minimum.wid1 or:3 h: mean foof height, in feet, except that eave `eight ___ be used when 0<=10 degrees; and 0: foor slope from horizontal, in degrees. ETAL ECH, INC. EST. +957 7OJ5 W. SECOND CT. ...ALLAN. cL 33O+• RAMMS ENGINEERING, INC. .5° fi 2100 TaN sNcr. Sri 3N E B 000602° .wr.., no+:a ,v,e • 5