Loading...
REPAIR ROTTEN WOODPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date / ? /'/' Job Address o1L L N S Tax Folio t k ac)-Dc. O t 3 4 (O3 0 Legal Description 1p - 1 a ,moo � a,c. { Historically Designated: Yes No Owner/Lessee / Tenant l'• • 4 ' P t\-dS 6 \a 0.46V(L Master Permit # '7 37 Owner's Address `2...4 k . Contracting Co. g V M � m m N Nt�. c�o v Address `mil Qualifier " ° j�/ A/c/ SS# / Phon('o .S) ).cC - 9.J.e/ State # CgG 0( y21 Municipal # Competency # Address Address Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one WORK DESCRIPTION e p a-A EP wool:, a 6 c . 'r`'O a`'" S ,Rep ti Square Ft. Estimated Cost (value) , 3_69 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. e 6--hrykke � 0_40 4 Signature of owner and/or ndo President Date Notary as to Owner and/or Condo President Date My Commission Expires: LECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN n 07 ° FEES: PERMIT S0 '� RADON C.C.F. '‘‘) NOTARY Phone Ins. Co. Si a e of Contractor or Owner- Builder Date I a `' -9 ;'f _ 1, ° . SEAL . Ia1R My Commis ion • 9P y C ID. 3417 CaletSSION R 12t1M BOND 3 00 Date o /O TOTAL DUE ,3�{} APPROVED: ' Zoning Building / )/ 1 Electrical Mechanical Plumbing / Engineering ion Print 11 yr th.VITtuvscrel6CIt/tCIV 1 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION TAX FOLIO NO. // (7 2 O( o/j 4'j O PERMIT NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713. Florida Statutes. the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 1 44 ' X o 2. Description of improvement: ,t , e2,--,,�- , - a hiv,", ea.) Ase/ C/A- l 2 .C/3 X/F 3 Owner(s) name and address .?Ye A. £ tea/ J, Interest in property' 0 lire Name and address of fee simple titleholder: 4. Contractor's name and address: rj /ci,,, a �s ,U 6 - 2 2= s.", Amount of bond $ i(/ // 6. Lender's name and address ofornlr a �Q ers Name Sworn to and subscribe . before me this Notary Public Print Notary's Name - /f// /7 /J w.. f1 .r ti /'4 5. Surety:(Payment bond required by owner from contractor. if any) Name and address' 7R £ % 5� .D�tJJ /4 l crx. rn .s',' ,�e 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7.. Florida Statutes. Name and address: . /f/i9 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: y/7 9. Expiration date of !his Notice of Commencement. (the expiration dale is 1 year from the date of recording unless a different 4a1e is specified '`� ---- (4 Sol. CA •212 ..1 0.20,03 day of Li! 19 / /'" Prepared by: if, STATE OF FLORIDA, COUNTY OF DADE t McREBV cePrrFr /1,•0' Ibis is original Mei i� s o lru Ay of /h ° "re °•- -Q,,.� L day of w rvE!s ray h h ' n ,nd p l ci +� Seal. AA a . 1919 E I A.iVt �U�r)i� CL�RP! c.: By cjc Address: fr Date /0/28 98 Job Address 2'e( 4/A' /o/ f � f /Pet Tax Folio Legal Description Historically Designated: Yes No X Owner/Lessee / Tenant /l7i Owner's Address ,e %/ 'VE /0/ 'f .I>�£c� / " 54 ,-Ls Contracting Co. jr/i., ��, %ma G . f��� /� %r ? c , WORK DESCRIPTION //79,9,� Sign My Commissio on • o President Date o owner an I -97 S 3 - A -D 4/3. 20a3 r , /'rig �? 4/74 ry - 2 F as to • 1 '' 1 �t r i 1 ate '• °I 5IOIV NO. CC714)03 ISSION EXP. M 1 -- � FEES: PERMIT J 0 RADON APPROVED: Zoning Building Mechanical PERMIT APPLICATION FOR MIAMI SHORES VILLAGE yn /in/ L her 2 -sp G.. U G QA. c✓t/- C.C.F. NOTARY Master Permit # 9 9 / Phone (3 7 S 9 - 6 7/0 Address 2 ) j - i 92 "=`/, fart/ /77/.,; Qualifier /C G4.e,- SS# - - / - Phone <,3(S, 7.S - 732/ S t a t e # C e 7 f 7 2 ' 2 y Municipal # Competency # Ins. Co. Architect/Engineer /r /, Address Bonding Company // /, Address Mortgagor /( / //� Address Permit Type (circle one):UILDIN C ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN Square Ft. Estimated Cost (value 5-0 0 i 2 7J �oo•+.J WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regular g construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. / /��o f Contractor or Owner-Builder K Vcl • e_,- //-3 y' Notary as to o ' rr.n " t#1Y der Date — My •t �Y5 M Conit�}on . S TATE OF FLORIDA COMMISSION NO. CC714103 MY COMMSSION EXP. MAR. 12002 , Electrical BOND 300 TOTAL DUE Plumbing Engineering Miami Shores Village Building and Zoning Department Miami Shores, Fl 33138 RE: Property located at (address and legal description) 2 4G NE 101 SAAreel �`1\ l (\'■ 51 -loRFS ovi cz :)3) Gentlemen: As legal owner of subject property, I request the of permit number 4-156 4 - issued to A Ss ,(e)t for the following reason: W„Cl_. , ,, rx)wt vac.te A)\. G>,,��. �v,.,e r c� G \AJO4 4 S -I- 4eve), n ✓e VL tlfe LA fr de ,r ?e4'6A.A ^70 4 1 564- r,P-1 G \ cso Roo .c,, 5 Date of last inspection: 7 - I hereby apply as owner - builder, o authorize new contractor) G a- „ to apply for such permits as necessary to construct or complete the construction on subject property. I agree to hold Miami Shores Village, its. agents and authorized personnel harmless and relieve them from any responsibility or liability for any legal action or damage, cost or expense (including attorney's fee) resulting from the cancellation of the existing permit or the issuance of a new permit. I furthermore assume responsibility for the correction, if required, of work performed under the permit for which I am requesting cancellation. Very truly yours, G cA-2Q Z4ie5 G IG (print name) STATE OF FLORIDA COUNTY OF DADE: The undersigned, being the first duly sown, deposes and says that he/she is the legal owner of the above property. - Sworn to and subscribed before me this day of Cc (- yr.?? !9 - J )-2 .d 1 -- - Notary Public, State of Florida at Larg - � ,t Lo)1t_wv d HOLD HARMLESS (print name) Date c?7 Prime contractor (only if subcontractor holds permit or if change of qualifier). - 71 / 4 Hri /e Ca ,' Pecs 7 T Cbi 6 WO 6 FIIN_IL /GI tsZ zeor VA , / Th 1 pi 7/o 3PT74 L- $ Gft 1 s No t- is� ., A r s �� • /7c6 She1Qdi 'v9 G / /Ca F ' ' ' c • .� UL a .1. F 144 ptcR GAFGLAS® Specifications N - B - 5 - M/P6 and N - - - GAF NATERIALS CORPORATION Nailable Deck Sheathing Paper _ (II required) Rooting 2• SI Age 2• Side Lap r aal 1 GAFGLAS / Suraced ap Sheet Mineral 36" * GAFGLAS Base Sheet (nee below, GAFGLAS Ply North, South, and West Zones Nailable decks up to 6 inches per foot slope, except for lightweight insulating concrete decks which are limited to a maximum slope of 1" per foot. Wood, plywood. structural wood fiber, acceptable precast nailable decks. poured gyp- sum. For lightweight insulating concrete, see page 9. 38 Materials Sheathing paper (1 ply, if required) GAFGLAS Base Sheet GAFGLAS Ply (3 plies) GAF Materials Corporation Roofing Asphalt Interplies Cap Sheet (1 ply) Approximate Weight per Square Guarantees Available 220 -275 lbs. Specification Liberty Guarantees N- B- 5 -M /P6 20 yr. West Zone only, Wood Decks. N- B- 5 -M /P6 20 yr. Lightweight Insulating Concrete. (See page 9.) N -B -5 -M 2 +10, 10, 5 +5, 5 yr. Specifications • General • Application recommendations detailed on pages 17 -20 shall apply in addition to the following recommendations and specifications. Application of Roofing Membrane 1. Starti4 at the low point of the roof, lay one ply of GAFGLAS Base Sheet, lapping each sheet 2 inches at edges and not less than 6 inches at end laps. Nail along lap of base ply at intervals not to exceed 9 inches and stagger -nail down center of sheet in two rows with nails spaced at 18 inch intervals in each row. Use fasteners with integral metal heads atdeast 1 inch in diameter or square that are recommended by GAF Materials Corporation or the deck manufacturer. (See 'Special Instructions' below.) 2. Starting at the low pointlof the roof, mop three plies of GAFGLAS Ply shingle fashion; lapping each sheet 27 inches over the preceding sheet; solidly mop- ping to the underlying base sheet to provide four plies over the entire roof area. Asphalt Requirements Interply moppings of Roofing Asphalt must be applied in a continuous film and shall consist of approximately 25 pounds per 100 square feet of roof area with a tolerance not to exceed 20% plus or minus. The appropriate asphalt for the slopes involved must be used. Slope per foot Asphalt Type Up to 3' Steep ASTM Type 111 3'- 6' HT -Steep ASTM Type IV On slopes up to 'h inch per foot, Flat ASTM Type 11 may be used except in Florida, Texas, New Mexico, Arizona, and California. Surfacing Apply GAFGLAS Mineral Surfaced Cap Sheet in accordance with the application instructions on page 20, so that the laps are offset from the laps of the ply sheets. Special Instructions 1. See recommendation for use over gypsum decks on page 9. 2. Acceptable GAFGLAS Base Sheets include: STRATAVENT® (Vent lay) for Nailable Deck, GAFGLAS 175 Base Sheet, GAFGLAS' PLY 6', Ply 4. 3. If GAFGLAS PLY 4 or GAFGLAS PLY 6 is used as the base sheet over wood or structural wood fiber decks, a sheathing paper is required. 4. Over freshly poured gypsum and lightweight insulating concrete decks, STRATAVENT (Vent Ply) for Nailable Decks is required, see page 9. 5. For applications over lightweight insulating concrete decks, see page 9. 6. For "Nailing of Base Sheet," see pages 18 -19. 7. For roof slopes of 1 inch per foot or more, all piles must be back - nailed 4 inches in from the felt edge. See "Installation on Steep Roofs," Page 10. UL Classification 1.11 Class Substrate Slope A A B C NC C 2' 3' 3'/:' UL Chart Key 1. Substrate C = Combustible and Noncombustible Combustible = Wood planks, boards, etc., plywood (min. 15 /a inch thickness), oriented strand board (min. 'h inch thickness). NC = Noncombustible only Noncombustible = Steel, poured or precast structural concrete, lightweight insulating concrete, gypsum, structural wood fiber, etc. 2. Slope Maximum slope allowed, in inches per foot. • . A.P.aa.T. ,'7..w Q ` GAF MATERIALS CORPORATION General Recommendations presented on pages 17 -22 shall apply in addition to the I following application recommendations. Application Recommendations 1. On structural concrete decks, insulation may be secured with Steep Roofing Asphalt ASTM D312. Type III or the GAFTITE Fastening System. If Steep Roofing Asphalt is to be used. the concrete deck must be primed with Asphalt/Concrete Primer at a rate of 1 -2 gallons per 100 square feet and allowed to dry. 2. For steel decks, insulation must be mechanically attached throughout the entire roof area. See "Suggested Insulation Fastener Patterns ". page 8. or the current GAFTEMP Catalog and Factory Mutual Loss Prevention Data Sheet 1 - for attachment patterns. 3. Starting at the low point of the roof• apply two plies of GAFGLAS PLY 6 shingle fashion: lapping each sheet 19 inches over the preceding sheet: solidly mopping to the underlying substrate to provide two plies over the entire roof area. Steep Roofing Asphalt. ASTM D Type III, must be applied at the rate of 25 pounds per square. plus or minus 20 %. Over GAFTEMP Isotherm R an overlay of GAFTEMP Perlite or Composite Insulation is required prior to the application of the GAFGLAS Ply 6 felts. 4. Starting at the low point of the roof surface. set the roll of RUBEROID TORCH PLUS or TORCH FR in the course to be followed and unroll half of the roll where practical. Position the membrane to provide a mini- mum 3 inch side lap and a minimum 6 inch end lap. Using the propane torch. apply the flame to the surface of the coiled portion of the roll until the surface reaches the proper application temperature (approximately 350° F). The side lap and the end lap areas of the previously applied sheets must also be heated to provide proper adhesion. The flame should be moved from side to side and the membrane slowly unrolled while pressing onto the underlying surface.. As the surface of the roll is heated. it will develop a sheen. The generation of heavy smoke should be avoided as it is an indication that the surface is being overheated. When this half of the roll is secure. reroll the other half of the roll and torch in place in the same manner. Particular attention should be paid to burning off the release film on the selvage edge. A minimum of / inch flow out of modified bitumen compound is required at all seams. Field seams should not be troweled. At the 6 inch minimum end laps. suffi- cient heat must be applied to the granule surfaced RUBEROID Membranes to cause the granules to sink into the top surface coating to assure a receptive surface for bonding to the overlapping next roll of RUBEROID Membrane. RUBEROID FR UL Classification UL Class Surfacing Substrate Slope Insulation Specification A Granule C 'A" 4C I -2 -1 -TGPFR A Granule NC 2" A I -2 -1 -TGPFR UL Key Chart 1. Substrate C = Combustible and Noncombustible • Combustible = Wood planks, boards, etc.. plywood (min. , inch thickness), oriented strand board (min. f inch thickness). NC = Noncombustible only. Noncombustible = Steel, poured or precast structural concrete, lightweight insulating concrete. gypsum. structural wood fiber- board. etc. 2. Slope Maximum slope allowed, in inches per foot. 28 RUBEROID® Specifications I -2 -1 -TGP and I -2 -1 -TGPFR 3. Insulation 4C = GAFTEMP Isotherm. R, Composite, Minimum thickness 2 inches plus a layer of GAFTEMP Perlite. 1 A = GAFTEMP Isotherm R or Perlite, any thickness. Substrate - Insulated deck using GAFTEMP Perlite, Isotherm R or Composite. For Isotherm R, see Application Recommendation #3. Slope - Up to 3 inches per foot. Materials GAF® Materials Corporation Asphalt/Concrete Primer. if required), . GAFTEMP® Insulation GAFTITE® Fasteners (if required) GAF Materials Corporation Steep Roofing Asphalt ASTM D -312 Type III GAFGLAS PLY 6® (2 plies) RUBEROID TORCH PLUS or TORCH FR Approximate Weight Per Square Total: 195 -205 lbs.' 'Plus weight of insulation and fasteners. Guarantees Available - Specification RUBEROID Liberty ' RUBEROID I -2 -1 -TGP, I -2 -1 -TGPFR 20, 15,12,10, 5 12,10 The following changes are to be made in these specifications and all of these items listed on this addenda sheet shall supercede the same items: hereto -fore mentioned in these specifications. 1. Galvanized steel tubing shall be used throughout. 2, Omit Venetian Blinds, but install recessed type Blind Guides. 3. All interior plaster shall receive 3 coats lead and oil paint, in colors selected„ 4. The following allowances shall be made: Hardware. Schlage or equal x$60.00 Lighting Fixtures 50.00 Mantel and Hearth. 35.00 Medicine Cabinet 10.00 5. The following list of plumbing fixtures has been selected; All Kohler. K -2720 B 17 x 19 with Lays K -8100 Combination waste and supply #920 Trap K -3700 T.B. Clos. K -4726 Seat #9430 Sypply ADDENDA K -555 C 5 Tub K -7510 Bath and Shower Fitting K-9710 Rod and Hooks (no curtain) K -6420 A 20x30 A.R. Flat Rim Sink K-8686 Swing Spout Faucet #9101 Strainer Sheet 1. SPECIFICATIONS SPECIAL NOTE: All work done under these General Specifications and specifications for the various trades bound herewith shall be subject to all the rules and regu- lations of the local building codes in effect in the location in which the build- ing is to be erected, and to all the requirements of construction for buildings of this class, as laid down by the Federal Housing Administration. DRAWINGS: The plans as drawn and the accompanying specifications are to be the basis f this contract and are to be of equal force. Any work herein called for by these specifications although not shown on the plans, or any work shown on the plans and not mentioned in the specifications must be considered as part of this contract as if work had been both shown and specified. Parts of the work not specially detailed shall be constructed in the customary manner for the class of work, and so as to maintain the strength and complete the parts they compose. Figures shall be used in preference to scale, and large scale drawings in preference to those of smaller scale. LIABILITY INSURAITCE: Contractor shall at all times during the progress of the work, carry the y oorrect amount of Liability Insurance in accord with all local existing laws and all of those of the Workmants Compensation Act of the State of Florida. SCOPE OF WORK: Contractor shall clear the lot for the building, and shall furnish all labor, maEerials, transportation, fuel, energy, scaffolding and tools as are required for the full and complete erection of the building as shown, and he shall construct in the best and most workmanlike manner, a complete structure with every thing incidental thereto, as shown on the plans, mentioned in the specifications or reasonably implied therefrom. PERMITS AND FEES: Contractor shall comply with all rules and regulations affeot.. ing his work and shall pay for all permits, fees, etc. as are required. LAYING OUT OF WORK: Contractor shall locate the building on the site from the dimensions given and shall be responsible for the accuracy of same. All set back rules of the local building code shall be adhered to. Trenches shall be dug for foundations to the levels shown, these trenches shall be level and free from all refuse, batter boards shall be erected as required. Bottoms of footings to be at least 6" below natural grade. Tops of footings to be at least 4" below finish grade. CLEAR SPACE UNDER JOISTS: Level off the high places in the grade under the house and provide at least 17 4" shall be provided between the bottom of the girders and the grade In case this minimum distance can not be obtained these girders to be pressure treated or steam treated at the plant by an approved method of treating. VENTILATION OF SPACE UNDER HOUSE: Provide suitable vents in all outside foundation walls to properly ventilate the space under the house. Vents shall be placed at locations that will be as shown, shall be 8 x 16" and shall be screened on the ins side with hardware cloth or screen fabric nailed directly to walls. BACKFILLING: After concrete has set in excavations for footings the contractor shall fill in around walls and slabs to 3" under levels shown, making a neat slope away from the building. GRADING: Contractor shall do all rough grading and shall leave premises smooth, 1 ready for reoeption of top soil and landscaping. TERMITE SHIELD.: An approved, continuous metal termite shield shall be used, placed at the tops of all foundation walls and piers and around chimneys and fire.. places. The shield shall be neatly made of 28 gauge Toncan or Armco galvanized iron and all joints Shall be soldered. Shield shall be extended to within 6" of exterior face of wall, and be bent down at an angle of 45 degrees with an extension of at least 3" from face of inside wall. DRIVEWAY: Provide 2 wide cement driving strips, spaced 2t - 6" apart from street to Porte Cochere as shown, reinforce with 440 road mesh. Cut down curb, and provide radius splays as required. WALK: To be a broken cement steeping stone walk. . Sheet 2. CONCRETE LND MASONRY GENERAL: This part of the work calls for all labor and materials for all plain and enforced concrete work, all block work, brick work, cement floors, tile vents and any and all other masonry work to fully complete the work as shown. Cement shall be Portland cement, conforming to the current standard specifics tions of the American Society of Testing Materials. Sand shall be clean.. sharp, and free from foreign matter. Concrete block shall mmet the requirements of the local building code, to be 8x8x16" and shall bear Underwriters label. Broken rock to be clean, hard and sharp. All vents to be as noted, and all to be screened. FORMS: All forms shall be tight, straight and plumb, and shall be braced to support all concrete until same has set, and forms shall not be removed until con- crete has set thoroughly. Loads shall not be placed upon concrete until sufficient strength has developed to support such loads. EXTERIOR FOUNDATION?J!LLS: Walls carrying joists shall be 12" thick of poured concrete or masonry and shall be made level by use of a continuous cement cap of 1 - 2 Portland cement mortar, minimum thickness of 2" neatly troweled. DOOR AND WINDO. JAMBS: Caulk all frames as they are set with approved caulking compound. Use Peoorawor equal, and test all openings for watertightness. CEMENT MORTAR: Mortar for all masonry work shall be composed of 1 part cement and 3 parts sand BATH FLOORS: Tile floors supported on wood construction shall have concrete under- floor nofless than 3" thick. Boarding supporting the underfloor may be let down between joists, but not to exceed 1 ". Chamfer top of joists. CONCRETE SLABSs In no case will a slab be allowed on fill, where area of slab is 1 ft. In cases where area of slab is over 150 sq. ft. same may be placed on fill* but in this case, vents shaft shall be constructed in accord with F.H.A. requirements. Slabs to be reinforced with rods, or a minimum of 6.6.- 10-10 road mesh and edge of slab and slabs under load bearing partitions shall rest on masonry bearing walls. MhSONRY WORK: All block work shall be laid up true and plumb in a neat and work manlike manner. Before setting and building any masonry materials into walls it is to be carefully vret down, in order to prevent the too rapid suction of water from cement mortar. PLATES: Shall be anchored to beam, with 1/2 x 12" bolts. Use 2 x 6" plate and bolt every 5 Set approved anchors properly placed in each of the concrete beams to anchor each 4th ceiling joist and rafter. Partitions running at right angles to joists to be anchored at cap plate with joist anchor. SILLS: All sills shall be bolted to masonry walls with 1/2 x 18" bolts, bedded firmly in the masonry and spaced not more than 6 apart. Poured concrete founds -4 tion walls to have sill anchor bolts installed not less than 6 apart, and shall extend at least 8" into concrete. When piere constructed of masonry units are used, the anchor bolts shall extend through the pier, into the concrete footing. REINFORCING STEEL All reinforcing steel shall be Medium Open hearth Steel and shall be free from paint and oil. Slight rust will not be objectionable, but no steel shall be used that shows a heavy rust or scale. Foundations to be as shown. . All buildings shall have a continuous wall tie beam, placed at roof line, with a depth of at least 12 ", reinforced with 4 - 5/8" rods, 2 at top and 2 at bottom of beam. All window sills shall be poured concrete of at least 6" depth by width of wall, reinforced with 2 - 1/2" rods. All window and door lintels must be reinforced concrete, using 2 - 5/8" rode. All gables that have a span of 12' or over, or contain more than 25 sq. ft. shall have a tie beam, not less than 8" high by width of wall, reinforced with 2 - 1/2" rods and anchored to tie beam with 2 - 1/2" dowels. CONCRETE: Shall be 1 - 2 - 4 mix. The maximum of water to 1 sack of cement shall be 6 gallons. CEMENT FINISH: All floors so marked shall be 1" thick and mixed 1 part Portland cement and 2 parts sand. Where color is called for it shall be integral. Sheet 3. ROUGH CARPENTRY GENERAL: Construct all forms for concrete and masonry work, and do all cutting and patching as nay be required for the other trades to install their work. FRI.Iv: NG TIMBERS: To be =,',2 common L.L.Y.P. or Douglas Fir, coastal type. All plates bearing on masonry walls and 18" of the ends or parts of all floor joists, sills, or girders contacting masonry shall be treated with Celcure or Greosote • before erection, Floor Joists: 2. :10 or 2x8" as shown, spaced as shown, double under partitions. Ceiling Joists: 2 x 6" or 2x8" as shown, at 16 ", well braced if span is over 12=. Rafters: 2x6 or 2x8" as shown, spiked and tied. Roof Plate: 2x6" bolted every 5 Studs: 2x4" at 16 ", bolted to :masonry walls with 3 — 1/2" bolts Bridging: 1 x 3" every 8i of span. Partition Plates: 2x4" set on edge and doubled. Openings over 2 shall be trussed. Roof Sheathings 1 or 7/8 x 6" T & G 42 common pine. GROUNDS AND FURRING: Grounds for plastering shall be set as required. 1x21 fui ing strips at 16" shall be applied to all exterior masonry walls with out naila Treat all strips with Celcure or Creosote before erection. Bath Room ceilings may be furred to 8! if desired. Furr chimnay breast with metal furring. SUB FLOORS: Old fors:: lumber in sound condition may be used for sub floors. It shall run diagonally with joints parallel to and over joists. If old form lumber can not be used, sub floor to be 1 x 61' t pine, straight edge, laid diagonally, SCUTTLE: Build into ceiling where indicated on plans a 24 x 24" trap door to Attic. ACCESS DC R: A door of a minimum size of 16 x 20" shall be provided in the foun- datiion wall to give access to the space under the house. Use cement sill at this opening to prevent surface water from running under the house. FINISH CARPENTRY WOOD FLOORS: To be Select Oak, Sand, fill, stain, give 2 coats shellac and 1 coat of approved floor wax. TRIM To be Cypress orI hite Pine, provide base and shoe mould. DOORS: Will be shown on door schedule. Screen all doors with #18 mesh bronze wire, where screen doors are called for. Screen porches with same. DOOR FRAMES: Interior and exterior door frames to be Cypress, Caulk against frames when set and after stuccoing. SHUTTERS: To be as designed and to be Cypress or Plywood as selected. EXPOSED BELYZ : Any exposed beams to be Cypress of the sizes shown, and sheath— ing to be 1 x 6" V groove Cypress of sizes V groove as shown. CLOSETS: Shall be fitted with 1 x 3" hook stripmand 1" hanging pole. Shelving to be as indicated, Linen closet to have 5 shelves. Finish of closets to be same as that specified for adjoining rooms. KITCHEN CABINETS: To be as detailed and to have slab doors. MEDICINE CABINET: Provide and install a standard sized recessed type medicine cabinet in each ath. Set botton_ line of cabinet 48" from floor at top of wainscot. LINOLEUM: Kitchen floor to be covered with standard gauge linoleum, in color and pattern as selected. FINISH HARDWARE: Provide and set all finish hardware to fu11y o,omplete the job. All to be of good grade and shall be installed level and plumb. HARDWARE 460.00 LIGHTING FIXTURES ....50.00 MANTEL AND HEARTH ....35.00 MEDICINE CABINliT .....10.00 ALLG ANCES Sheet 4. METAL CASET.ENTS All steel sash shall be Campbell Light Section, Hopes Holford or equal of the sizes shown, and shall be installed complete with all required operating hardware. All ventilators to be screened with 18 mesh bronze wire set in steel frames. All sash to be set in mastic cement, plumb and level to the heights indicated and all windows and doors shall be glazed with D.C. "A" glass. Glaze all steel sash in accord with manufacturers directions. Back putty all door glazing. 4indows and window frames: All window frames to be Lifsey pre -cast window frames. CAULKING AND ;fEATHERSTRIPPING All exterior frames of either wood or metal shall be hand caulked against masonry or frame and where stucco is applied against stucco. Use Chamberlain or Pecora or equal caulking compound. Door schedule will show all thresholds and weatherstrips. ;here called for use an approved threshold as manufactured by Chamberlain or equal. ROOFING A;.:D SHEET METAL GUARANTEE: All roofs and flashings shall be guaranteed to be watertight and perfeo'b for a period of 3 years and Contractor shall make good without cost to Owner, all leaks during that period. COPPER WORK: All flashing and counter flashing where specified, or where usual or required to make the work watertight, shall be 16 oz. hot rolled copper. All chimneys and vertical masonry walls extending above roofs shall have step flashing not less than 8" high and counter flashing lls. built 4" into ter FELT: All pitched roofs shall have 1 - 90 lb. slate surfaced felt mopped to the sheathing, lap all joints at least 3" and mop well with hot asphalt. ROOFING TILE: To be Cement Barrel Tile in color selected and shall be laid in best approved manner. Vertical courses shall not exceed 12" on centers and each tile, both cover and pan shall be lapped at least 3 ", leaving not over 15" of each tile exposed to weather, Pans and covers shall be laid in cement, care being taken to fill all openings between tiles. LATHING AND PLASTERING GENERAL: Furnish all labor and materials for all lathing, plastering and stucco work to fully complete the job as shown. SHEET ROCK: Shall be used throughout as a base for plaster. It shall be applied in strict accord with manufacturers directions and shall be level and plumb. TOTAL LATH: Shall be galvanized 3/8" mesh Clinton_ Cloth. Strip all corners and bull noses with 12" strips. Lath eave moulds and elsewhere as indicated. Metal lath shall be applied for all tile bases and where stucco is carried on studs, for all tile wainscots and under all curved surfaces. Metal lath all arched openings with 10" strips. PLASTERING: Shall be 2 coat work of best grade Gypsum plaster, and shall be textur— ed as directed. Kitohen and Bath to have smooth finish plaster, troweled smooth as glass, free from all marks and discolorations. Balance of plaster shall be Art Cement. STUCCO: All stucco shall be 2 coat work, composed of 1 part cement and 2 parts sand to whioh has been added io% Tiger Finishing lime or equal, and Sec waterproof— ing in accord with manufacturers directions. First coat of stucco shall be well scratched to receive second, and stucco shall finish 5/8" thick. GENERAL: mentioned and to be lath, all BLINDS AND GUIDES Provide and set recessed type Venetian Blind Guides, and Venetiat Blinds through.- out. Venetian Blinds to be as manufactured by Maxwell or equal. KITCHEN: Tile back TILE ?'YORK Furnish all labor and materials for all tile work shown on the plans or in these specifications. All tile work to be laid on a full cement grout level and plumb. All wainscot tile to be laid in cement grout on metal floors to be laid in waterproof cement grout. Provide tile top, back, and ends, to cabinets on each side of sink. to be 1 .. 8 ", and all colors to be selected. Sheet 5. BATH ROOMS: Shall have a 4 tile wainscot except at back and ends of tub, where it is to be 51 — 6". Provide tile floor and base and colored strip at top of wainscot. All colors to be selected. Provide 2 — soap dishes, (one with grab) 2 — 24" towel bars, 1 tumbler and tooth brush holder, and 1 recessed type paper holder. ENTRANCE: Provide tile steps as shown. SCREENED LOGGIA: To have tile floor as selected. INTERIOR WINDcXT SILTS: To be tile as selected. CLEANING: Thoroughly clean all tile when work is completed. PAINTING GENERAL: This part of the work calls for the finishing of all surfaces which are to be painted or stained. All materials to be of trade marked brand, Kyanize, Lucas, Pratt Lambert or equal and shall be brought to the job in the original con.. tainers and shall be used in strict accord with manufacturers directions. WORKMAINTSHIP: 411 dust. dirt and all foreign matter shall be completely removed from all surfaces before any paint is applied. :Tcodwork to be dry and free from dampness during entire painting operation.. Woodwork. to be sanded smooth, all nail holes and cranks to be puttied full and smooth and putty shall be stained to match the color of any stained or varnished surfaces. PRIMING AND BACKP4INTING: All woodwork to be painted shall be primed with lead and oil paint, and awl trim shall be primed before plastering. Exterior wood frames and window bucks shall be given a coat of Creosote on the back before erection. The bucks of all cabinets to be given a coat of shellac before fitting. EXTERIOR 'TOOThTORK: To have 3 coats of lead and oil paint in color selected. INTERIOR WOOTTORK: Kitchen and Bath to have 1 coat primer, 1 coat lead and oil and 1 coat enamel finish. Balance of interior woodwork to have 1 coat primer, and 2 coats of lead and oil paint. PLASTER WALLS AND CEILIiGS: All interior plaster shall receive 3 coats lead and oil paint, in colors selected. STUCCO: All stu000 shall have 2 coats approved waterproof paint of the following formula: Mix well 2 bags finish lime, slacked for 24 hours, 6 gallons Sec watery proofing paste, 12 lbs. table salt, color as selected. Mix well, add water to make of a creamy thickness and inmiediately before applying to walls to each 10 qt. pail of paint, add 3 lbs. "Thite Portland cement. Stir well, and keep well stirred while using. METAL SASIi: Shall have in addition to the shop priming, 2 coats approved metal paint in color selected. CEILING BEAMS: 1.Iay be painted or stained as Owner wishes. CLEANING: Thoroughly clean all glass, fixtures,.and all paint spots from house when work is completed. ELECTRIC WIRING GENERAL: All wiring shall be installed in striot accord with all rules and regula* tions of the local building code, all those of the local Power and Light Co: "and all those of the National Board of Fire Underwriters. CONDUITS: Galvanized steel tubing shall be used throughout. SERVICE: Shall be brought from the nearest point of the Power Co. lines to a loca— tion at the panel box, °properly connected to same, and branches of correct size run to all outlets as shoran. Install 60 or 100 Amp. switch meter test cabinet and Frank Adams 6 circuit panel for lighting and power. SPECIAL SERVICE: 4,here indicated on plans, provide such service as may be required for range, r e?Tgerator etc. SWITCHES AND CCEPTACLES: All switches shall be '; or G.E., tumbler type. All Sheet 6. plug receptacles shall be duplex flush type, set 10" above floor or as noted,. Switch plug plates shall be Ivory Bakelite. BELLS: Provide push buttons as shown, and connect to annunciator at location shown. RADIO PLUG AND AERIAL: Provide a radio plug at location whosn and connect properly o aerial yr c Wa e installed in Attic. PHONE OUTLET: Provide phone outlet at location shown. LIGHTING FIXTURES: Provide and set all lighting fixtures to fully complete the job as shown Same to be of good grade and shall be installed level and plumb. GUARANTEE: All workmanship and materials shall be guaranteed for 1 year. PLUMBING GENERAL: These plans contemplate the installation of a complete system to be in- stalled in strict accord with all local and State sanitary codes. SEPTIC TANK AND SOIL PIPES: Provide and install a concrete Septic Tank of the size required by the "code, and provide same with required disposal field. Lay a 4" soil pipe from Septic Tank to all pipes draining from the house. Pipe to be first quality cast iron of the weight known as standard and shall be laid straight and true to grade. WATER PIPES: All hot and cold water pipes shall be Wheeling galvanized steel. Pro- vide andtings and run hot and cold water lines to all fixtures except toilet and hose bibs, which will have cold water only. Bring in from the nearest point of the Water Co., main a 3/4" supply pipe and run branches of correct size to all fixtures as shown. Place all required shut off valves. Provide and install N.P. sill cocks as shown and connect to cold water supply. SOLAR SYSTEM: Provide and install, complete with all soldering, flashings, connections to hot and cold water lines, and all work to make a complete Unit a Giffon or Solar Water Heater Company solar system. Tank to be of 66 gallon capacity and coil to be -;,8 coil. PLUMBING FIXTURES: The following list of White fixtures has been selected from the Kohler Co. catalogue and shall be installed complete with all fittings by the Plumber: K-2815 20 x 18" Hudson Lavatory K -8182 Faucets, plug and Chain. C.P. Supply and 17 gauge Trap K -3700 P.B. lellworth Closet K -4726 Triko Seat K -9430 C.P. Supply and Stops. Kw-555 5 Recessed tub K -7510 Bath and Shower Fitting K -9710 Curtain Rod and Hooks (no Curtain) K- 6420 -. 30 x 20 A.R. Flat Rim Sink 8686 Swing Spout Faucet 9101 Duo Strainer.