Loading...
ROOFINGIssue Date: 1/29/2007 Owner's Name: RUTH PUMO Permit Type: Roof Work Classification: Roof - New Job Address: 1500 101 Street NE Miami Shores Village, FL Contractor(s) Phone OBENOUR ROOFING SHEET META 305 - 757 - 2612 Primary Contractor Yes Additional Information Type of Work: New Roof Classification: Residential Additional Info: In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Fees Due CCF Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $84.00 $28.00 $425.00 $9.00 $10.62 $556.62 Invoice Number RF - 1 - 07 - 27339 Total: ruf Amt Due $556.62 Amt Paid AN 3 0p Building Department File Copy Applicant Signature Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Expires: 07/28/2007 Parcel #: Block: Section: Permit Status: APPROVED Permit Number: RF -11 -06 -2884 Phone: Total Square Feet: Total Valuation: Required Inspections 1132050350020 Lot: PB: 7507 $ 140,000.00 Tin Cap Hot Mop Tile In Progress Up Lift Report Final Roof NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. !Inspection Number :I - 11-06 7 2884 Inspection Date: 06/18/2007 Inspector: Grande, Claudio Owner: PUMO, RUTH CL. Job Address: 1500 101 Street NE Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Building Department Comments Friday, June 15, 2007 Miami Shores Village, FL Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 1 of 2 JUN 1 9 2007 Passed Inspector Comments 1 i S'" Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until !Inspection Number :I - 11-06 7 2884 Inspection Date: 06/18/2007 Inspector: Grande, Claudio Owner: PUMO, RUTH CL. Job Address: 1500 101 Street NE Project: <NONE> Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Building Department Comments Friday, June 15, 2007 Miami Shores Village, FL Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 1 of 2 Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test(P or 9 1 26 % �1� 51 T -C47) C 7) 76 � i�l� 2 �6—� 27 52 77 3 28 53 78 4 29 54 79 5 30 55 80 6 31 56 81 7 32 57 82 8 33 58 83 9 34 59 84 10 35 60 85 11 36 61 86 12 37 62 87 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 46 71 96 22 47 72 97 23 48 73 98 ✓ 24 49 74 99 25 i 50 ,i 75 �e.--- 100 TE SPECIFIC INFORMATION Owner's Name t9 Permit # . 2-84941 Job Address i D tire IC L T y , ' 1 A..{_ --&t p.53� 1 P Roofing Contactor• -C7L�a. 0 0 L9 R- Cr/DC Type of Tile: n Nit 1 t',1 , •- Q-e9 I S :0...c Approximate Roof Height: ` feet Type of Access to Roof: Scaffolds - Ladder Other Approximate Square Footage of Roof 9 DP ft Required Testing Force: 35 lbs. Testing Equipment: Chatillion 100 Date Tested • I -0 4 THIS REPORTS ITTED BY: Lab Certification # 98 0608.04 State of FL Certificate Authoriza ion # 4100 U.S. SOUTH Engineering & Testing Lab., Inc. 6065 N.W. 167th Street, Suite B -23 • Miami Lakes, Florida 33015 Telephone: (305) 558 -2588 • Fax: (305) 362 -4669 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPILANCE PROTOCOL TAS 106 TEST RESULTS P = PASS, F = FAIL IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. .4.1 ,il Date Installed: Roof Pitch: Project No 9 4 6 7 ,��ZZ-0 3; 11'2- Job t r .�' 4017 t= tO l Sheet Number Zof Contractor P ) Ot,2? C c: V A' Checked By Scale E.2 l m Sketch of Roof Si1■■iiii 11■i111 IF ■ rental • • a``ii■L!inr17l • ulawavirmom resmixaiiimmal ■ ■'`_,,�iiIIri•■1 • liWAINFO!►.Ill••■1 • ■VIM■sr%I/wIIPIII ■ lit :► ■I■a■■rMINWPW" GfL".Lm.g.-.j l ®♦il=ga. • 11■tiII■■■ my 67 �" V° IIIMMII■ EMI pr . IIM 1'7■■ IL's ■`.IN■ II■1 14I I 0,11 go 0 4in mrairms IieliliouI ,..v......, ,. Notes: 1 4 APR 252007 Passed Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 04/2412007 Inspector: Grande, Claudio Owner: PUMO, RUTH Job Address: 1500 101 Street NE Project: <NONE> Building Department Comments Monday, April 23, 2007 Miami Shores Village, FL Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 i nspection Number: INSP - 33702 Block: Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Tile In Progress Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 1 of 2 / MAR 0 6 21112 Passed 1) Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until w 'Inspection Number I NSP- ermit Num nos �.. - 0 Inspection Date: 03/05/2007 Inspector: Grande, Claudio Owner: PUMO, RUTH Job Address: 1500 101 Street NE Project: <NONE> Miami Shores Village, FL Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Building Department Comments Friday, March 2, 2007 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Hot Mop Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 2 of 2 Inspection Date: 03101/2007 Inspector: Rodriguez, Jorge Owner: PUMO, RUTH Job Address: 1500 101 Street NE Project: <NONE> Miami Shores Village, FL Building Department Comments Wednesday, February 28, 2007 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 s ion Number: INSP-33 Perrnit Num1 I F -11-06 -2884 Block: Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 1 of 2 Infractio Passed Comments TIN CAP SPACEING False MAR 0 2 2001 Passed Inspector Comments 03-0 l— 0 7 Failed Correction Needed • Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 03101/2007 Inspector: Rodriguez, Jorge Owner: PUMO, RUTH Job Address: 1500 101 Street NE Project: <NONE> Miami Shores Village, FL Building Department Comments Wednesday, February 28, 2007 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 s ion Number: INSP-33 Perrnit Num1 I F -11-06 -2884 Block: Contractor: OBENOUR ROOFING SHEET METAL & SUPPLY CO. INC Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132050350020 Lot: Phone: 305 - 757 -2612 Page 1 of 2 Job Address (where the work is being done) City Miami Shores Village FOLIO / PARCEL # City Qualifier Name Shores Miami Village cit Architect/Engineer's Name (if applicable) Value of Work For this Permit $ i O 00 * * * * * * * * * * * * * * * * * * * ** Submittal Fee $ Notary $ Scanning $ 4.00 Bond $ Structural Review. $ Permit Fee $ Training/Education Fee $ Radon $ Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 ) 756.8972 BUILDING NOV 3 0 2006 L Permit No.4 4 - 0` ' PERMIT APPLICATIONS Y: C, / L) Master Permit No. FBC 2004 Permit Type (circle): Building Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder) EN NkD Owner's Address /5 Q ,t/ E /o / sre ft j City, / S /DO S State FL Tenant/Lessee Name County Miami -Dade Is Building Historically Designated YES NO V /566 /✓/ : /o/ ST,�'geT Contractor's Company Name O/3 F J./OV e. ZOQCi ni Contractgr's Address c l3OJ NE le oJJE A /a/ 4-kW C yca,e€ 5 State _A"L Q/ y Zip 3rd "05 Phone # 05 757-,2_ 6 / 2- State Certificate o r Registration N o.0� Certificate of Competency No. ( .$ ['New OWIe[ GI * * * * * * * * * * * * * * ** *F * * * * * *. ,0, $-CEO Square / Linear Footage Of Work: 7 Type of Work: ['Addition ❑Alteration Describe Work: A(L. ' LA) Awl Eggc4,,JA. /Z Ard Cfolar Ckt ft s A- D 2 /e6. re,,t4 r Q , , 1, /L IdE W/ DPBR $ Zip � /3g Phone # CCF$ Phone # Phone # Technology Fee $ Zip .33/3 322 ?S7 26/ g Repair/Replace ❑ Demolition Too G 1 ►tJ 7 LL 14/ • Gt✓ /G **,*** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** CO /CC O-(o2 Zoning $ Code Enforcement $ Double Fee $ Total Fee Now Due $ CQ • 2_ See Reverse side - Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS. and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all. work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit ith-an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. 1 the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signat Owner or Agent Contractor The foregoing instrumenkwas acknowledged before me this 3) The • egos instrument was acknowled ed before me this day of L217■ , 20' , by ( - 4 ■ I _ 3 .( , day of L.20 ✓ , 20 °` , by -S' Oik.utzei -, who is personally known to me or who has produced who is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: (Revised 02/08/06) Y PUBLIC -SLATE OF FLORIDA SANDRA D. HART )rnss‘,nccION = DD40380R � 1 E.PI.RES: APRIL 02; 2009 Bonded 7hru Atlantic Bor.dir,g Co., Inc. NOTARY PUBLIC: b Zip "t,' Y ' BUC-ST :\TE OF FIOWDA .��..� N DP..A D. HJItT f Sign: 'MS Commission . E . x : p'ires: COMI 5510. Fk�11�5' APRIL 02, 2009 Print: Bonded Thru A:lc.nric Bon c.18 Cu., lne. 0 My Commission Expires: t • • APPLICATION APPROVED BY: �� ' / / Plans Examiner 1 Q Engineer Zoning NOTICE OF COMMENCEMENT A RECORDED COPY yy MUST BEE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. IZECX.0 ��J6M TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF MIAMI -DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street/address: 15 TC fJE (01 3 2. Description of improvement: 3. Owner(s) name and address: Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: 3o/ rVE GM atte 5. Surety: (Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and-address: 7. Persons within the state of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owners designates the followi g persoos).,to receive a copy of the Lienor's Notice as provided ('J in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) � 4 - Signature ofOwner Print Owner's Name Sworn to and subscribed before me this Notary Publi Print Notary's Name My commission expires: 123.01 -52 PAGE 4 10/04 ffrailMikirt_lir flit t 1 13)41P � 0 l 5 litt. M I � �C�E WAAL- NO'T'ARY PUBLIC .51:ATE OF FLORIDA ti : rDRA D. HARD' r- - 1-0: SOt3 EXPIRES: APRIL 02, 2009 Bonded Tiro Atlantic Bonding Co., Inc. day of a/-4C 20 t)_? MATE OF FLORIDA, COUNTY OF DADE HEREBY CERTIFY that this is e opy of the mgmal filed • his office on ^ dayy of , A 20 (l/ WITNESS hand and Official Seal. HARV- IN CLERK . .. . n Courts 3y- 1111111111111111111 C.FiN 200780103661 OR BE; 25321 Po 2460; 0130 RECORDED 01/30/2007 10:21 :59 HARVEY RUVIHr CLERK OF COURT MIAMI -DADE COUNTYr FLORIDA LAST F'AGE 3),138 A - /a/ U 24 kza,/ 3* Prepared by Address: 3362-( SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to prov t ner with the required roofing permit, and to explain to the owner the content of the section. The p rovis' ti a 0 200 R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner . the 11/1;) contractor. The owner's initial in the designated space indicates that the item has been explained. 1. BP Aesthetics - Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that o� .�� �a• ng cow , shoulyl be ad ressed as part of the agreement between the o 7 2. 8 P Ken epiacing roofing, the existing wood roof deck may have to be ' l: �a`a ; ith the current provisions of Section R4403. (The roof deck is us removin g the existing roof system). 3. 6 P Co ° RI- n rt °ifs ; ommon roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants a adjacent units of roofing to be performed. . 4. 13 Exposed Ceiling: Exposed, open beam ceilings are where tAe underside the roof decking can be viewed from below. The owner may wish to maintain, the architectural appearance; therefore, roofing nail penetration of the underside of the cletkin.g may tict be acceptable. The provides the option of maintaining the appearance. • • ." • •• •• •••• 5. Ponding water: The current roof system and /or deck of the b'ading tay.rpt drain well and may cause water to pond (accumulate) in low -lying areas gf'tlte roof," • • Ponding can be an indication of structural distress and may require the review of a;,•�; professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. I� Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a buildup of water. Perimeter /edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. , v Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owner /Agent's Signature Date • .. • • • ontractor Signature Date PEY0 • • • 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or If Applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing /Calculation Documentation Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR -RAS 150 A,B,C 4,5,6,7 Asphaltic Shingles A,B,D 1,2,4,5,6,7 Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7 • • • • . Metal Roofs A,B,D 1,2,3,4,5,6,7 • Wood Shingles and Shakes A,B,D 1,2,4,5,6,7 .... Other As Applicable • 1,2,3,4,5,6 • • ..•• • • • • • ATTACHMENTS REQUIRED: SECTION 1525 HIGH- VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: ROOF ASSEMBLIES AND ROOFTOP STRUCTURES • •• .. • • • • • • • • .. • • • • • • • • •• •• •••• • • •••• • .••• • • • • • •••• • .••• • • • •. • • • FLORIDA BUILDING CODE — BUILDING 15.31 • • � yJ ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ❑ New Roof ❑ Low Slope ❑ Asphaltic Shingles Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Section A (General Information) Master Permit No. Process No. Contractor's Name Of eAJO '00D /A/6 Job Address 7500 /1/ /Q/ we/ ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel /Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ❑ Repair ❑ Maintenance Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) : TotAL(SF) • 7507 '75 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow tI itysi Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. •••••• •••• • • •• •• •••• • 0 1' 14 a 1 •• . .4 • • ••• • •. • 15.32 FLORIDA BUILDING CODE — BUILDING • • • • • • • • • • • • ••. • • Roof System Mapu ro..t0ttbe( or /WE lie Notice of Acceptance Number: 02 - /a //, Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): P1: 7.) 1 P2: /5 /4 P3: /9. /G Maximum Design Pressure (From the4r7duct Approval Specific System): ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Roof Slope: 3 : 12 Ridge V9ntilation? - - Mean Roof Height: Steep Sloped Roof System Description Deck Type: r (A)-4- Type Underlayment: ,4 tT.i4 4 ) 22 6 30 Insulation: Fire Barrier: • • • • • • .. • • • ••••• -. • •••• • • • • • . •••• •• • • •••••• •••. • • • • •• •. .. .• 11/d • • • . . • • .... • • • ....i i / ... ... •.•. •. Fastener Type &Spacing: 1 4',ev:(40.4t , j /4 4 *'L 'f,' Adhesive Type: ( - 77P6 1,7 Type Cap Sheet: [Ai5 2 (y Wfo Roof Covering: 4 //cl 44.04,✓A xi. /tem ser Type & Size'Drip A eo to Edge: � 15.34 Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Section D (Steep Sloped Roof System) FLORIDA BUILDING CODE — BUILDING • • " ••el Where to Obtain Information • • • Description Symbol Where to find • • • • Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier 1 Product Approval Restoring Motnent due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated ,. Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submit ed to the building official at the time of permit application. M required Moment Resistance* Mean Roof Height -> Roof Slope 1 1 15' 2 20' 2 25' 3 30' 4 40' 2:12 3 34.4 3 36.5 3 38.2 3 39.7 4 42.2 3:12 3 32.2 3 34.4 3 36.0 3 37.4 3 39.8 4:12 3 30.4 3 32.2 3 33.8 3 35.1 3 37.3 5:12 2 28.4 3 30.1 3 31.6 3 32.8 3 34.9 6:12 2 26.4 2 28.0 2 29.4 3 30.5 3 32.4 7:12 2 24.4 2 25.9 2 27.1 2 28.2 3 30.0 :4,4,4 For Moment based tile systems, choose either Method 1 or 2. Compare the values for M,. with the values from M. If the Mt values are greater than or equal to the M values, for each area of the roof, then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" Required Moment of Resistance (Mr) From Table Below *Must be used in conjunction w'th a list of moment based tile systems endorsed by the Broward County Board of Rule ,744 Appals. • • For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the F' values are greater that of c w:1 to the Fr Aues, • for each area of the roof, then the tile attachment method is acceptable. (P x L (P3: xL xL (P xl • 331 = /0.G7) - Mg: .38 = M , . 1 124 (P, Is x ..31 = 21.$1)- M = M /R" (P -91 x X 43 = 22•')_ Mg 3.38 = M3 /9. /6 Florida Building Code Edition 2004 High - Velocity Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) xw:= x w: = xw: Method 2 "Simplified Tile Calculations Per Table Below" Product Approval M Method 3 "Moment Based Tile Calculations Per RAS 127" -W: - W: ) -W: xcos0 =F,.1 x cos0 = F r , x cos H = F,.3 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Product Approval Mf 'Al . Product Approval M 442 f Product Approval Mf 44) • •••• • • • • • • • • • • •••• •• •• Product Approval F' _•_ • • • •••• •••• •• •• Product Approval F' • Product Approval F' • • • •••• • • •• • • • FLORIDA BUILDING CODE - BUILDING 15.35 MIAMICADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Ludowici Roof Tile, Inc. 4757 Tile Plant Road New Lexington, OH 43764 SCOPE: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this prod pct or material fails to meet the requirements of the applicable building code. • • • . • This product is approved as described herein, and has been designed to comply with the High.Yelocity fuincane Zone of the Florida Building Code. • • DESCRIPTION: Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg,XL Lanai XL, an8 Imperial' Clay Roof Tile •••• • • • • •••. • • • .. •• •.• • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, cit j, state and • following statement: "Miami -Dade County Product Control Approved ", unless othervJise noten herein. •••••• RENEWAL of this NOA shall be considered after a renewal application has been filed and theio has been no change in the applicable building code negatively affecting the performance of this product. • • . • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change .m the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 7. The submitted documentation was reviewed by Frank Zuloaga, RRC NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub - Category: Material: 2. PRODUCT DESCRIPTION Manufactured by Applicant Ludowici Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile Trim Pieces 2.1 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Flat Profile Roofing Tiles Clay 1. SCOPE This renews a roofing system using Ludowici -' Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial' Clay Roof Tile, as manufactured Ludowici Roof Tile, Inc. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. Dimensions 1= varies w = varies varying thickness Test Identifier 7161 -03 Appendix III 94 -060B 94 -084 Test Specifications ASTM C 1167 ASTM C 1167 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -76 Product Description Flat, interlocking, vitrified clay roof tile equipped with one nail hole. For direct deck or battened, nail -on, mortar set or apbc4i 'c set applications. • • .. • • Accessory trim, clay r221 eces for use at hips, rakes, ridges and Ally terminations. Manufactured for eacli ti14 profile. ' .. • . • • .. .. • Test Name/Report Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Adhesive Set) (Mortar Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 .• • .. •••• •••• bate.. •••• Dec, 4 March, 1994 May 1994 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 2of7 MESSAGE: 71lia+nt Skaaea 2/tllage bldg ep,aeee 10050 NE 2 "d Ave Miami Shores, Fl 33138 Phone 305. 795.2204; Fax 305-756-8972 www.miamishoresvillage.com FAX TRANSMITTAL COVER SHEET DATE: 1) 142.00 TO: FAX 5(13=158 - 4 FROM: VIVIAN CUBILLOS FAX (305) 756 -8972 Number of pages including cover:\ Importance: normal _L urgent ; please reply _; review • recycle _ "nos �S lb nl -o .3 or Ab ffmt 00C0-2n4- Tkaub Regards, VIVIAN CUBILLOS Bldg Dept Permit Clerk Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Celadon Ceramic Slate Roof Tile 5.50 1.33 0.896 Americana XL Roof Tile 6.01 1.33 0.896 Classic XL, Williamsburg XL and Lanai XL Roof Tile 6.65 1.33 0.896 Imperial Roof Tile 6.43 1.25 0.833 Test Aeencv Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 3. LIMITATIONS 4. INSTALLATION Test Identifier Test Name/Report Calculations Calculations Calculations Calculations Calculations Calculations Aerodynamic Multiplier 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. • • 3.4 Minimum underlayment shall be in compliance with the applicable •Roofillg Applications •r • • e • Standards listed section 4.1 herein. • • • • y • 3.5 30/90 hot mopped underlayment applications may be installed perpendfiltIrtb the roof slope unless stated otherwise by the underlayment material manufacturers puMti'sfied literature' 3.6 This acceptance is for wood deck applications. Minimum deck regain meats shsjl bg;in compliance with applicable building code. • • • • •• •• Date March 1999 February 1996 April 1996 December 1996 March 1995 April 1999 April 1999 •••• • • • 4.1 Ludowici ` Celadon Ceramic Slate, Americana XL, Classic XL, Williarisburg XL, IVY XL, and Imperial'Clay Roof Tile and its components shall be installed in t i t cbmpliance.with Roofmg Application Standard RAS 118, RAS 119, and RAS 120. • • • .. • 4.2 Data For Attachment Calculations NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 3 of 7 • •• • • • • • • Table 4: Attachment Resistance Expressed as a Moment - M (ft-Ibf) for Nail -On Systems • • Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Deck •`: (min.19 /M plywood.:.. •••• Battgns • • • Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile 2 -10d Ring Shank Nails 30.9 38.1 °••••• Battens 17.'.•'. 1 -10d Smooth or Screw Shank Nail 7.3 9.8 •••••• • • •• •• • • 4.9•••• • •••• 2 -10d Smooth or Screw Shank Nails 14.0 18.8 ..... • • • • 7.4 • 1 #8 Screw 30.8 30.8. 3.06 18_•••• ' 2 #8 Screw 51.7 51.7 ' • • . : 24.4.... 1 -10d Smooth or Screw Shank Nall (Field Clip) 24.3 24.3 24/•• 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. Table 3: Restoring Moments due to Gravity - M (ft-Ibf) Tile Profile 3 ":12" 4 "•12" 5 ":12" 6 ":12" 7":12"or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile 3.34 3.38 3.30 3.77 3.23 3.69 3.15 3.60 3.06 3.50 Table 2: Aerodynamic Multipliers - X (ft Tile X (ft3) X (ft Profile Batten Application Direct Deck Application Celadon Ceramic Slate, Americana XL, 0.219 0.237 Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 4 of 7 •' • • • • • • ' • • • Table 5: Attachment Resistance Expressed as a Moment M (ft•Ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile Adhesive 31.3' 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - M (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Celadon Ceramic Slate, Americana XL, Classic XL, Williamsburg XL, Lanai XL, and Imperial Roof Tile PolyPro 118.9 PolyProud 40.4 4 Large paddy placement of 45 grams of Poly Pro TM . 5 Medium paddy placement of 24 grams of PolyPro Table 5B: Attachment Resistance Expressed as a Moment - Mtift-Ib#t for Mortar Set Systems • Tile Tile Alt invent . Profile Application Resistance • Celadon Ceramic Slate, Americana XL, Classic Mortar Set . .39.0b - • • • XL, Williamsburg XL, Lanai XL, and Imperial •••• Roof Tile • • ' ..' • •••• 5. LABELING • • • • • • • • • •..• • • •••• All tiles shall bear the imprint or identifiable marking of the manufacturer or logA'Qf following statement: "Miami -Dade County Product Control Approved ". . • • 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 5 of 7 • • • • • • • • • 10 3/4" •es BOTTOM 8 PROFILE DRAWING 10 -3/4" 11■1 ••e ar I■1 r BOTTOM 16" RIGHT SIDE CELADON CERAMIC SLATE CLAY ROOF TILE 16" SIDE VIEW OF XL TILES XL CLAY ROOF TILES TOP 1 1 TOP VIEW OF XL TILES • • • • •. • • umo rICI I ` • • • • • •••• • • • • • • , • • • •••• •• •• • • •• •. •••• • • • • • • • • • • •• • •••• • • • • • • •••• • • •••• NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 6 of 7 • • • • •••• • • • • • • • • 4 " I PROFILE DRAWING L 1'a IMPERIAL CLAY ROOF TILE END OF THIS ACCEPTANCE TOP BOTTOM r i L 1 0 RIGHT SIDE END • • • • • .. • • • • • • • • .... .. .. • • .. .. • • • • • • • • • • .. • • • • • .. • • • • .... • • NOA No.: 02- 1211.02 Expiration Date: 01/31/08 Approval Date: 01/31/03 Page 7 of 7 • • • • • • • •••• • • • .. MIAMI•DADE BUILDING CODE COMPLIANCE OFFICE (B CO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA Polyfoam Products, Inc. 11715 Boudreaux Road Tomball, TX 77375 SCOPE: This NOA is being issued under the applic The documentation submitted has been re\ Review Committee to be used in Miami D Jurisdiction (AID). This NOA shall not be valid after the expi AI-IJ (in areas other than Miami Dade Co assurance purposes. If this product or mate the expense of such testing and the AHJ material within their jurisdiction. BCCO r that this product or material fails to meet th This product is approved as described herei Zone of the Florida Building Code, DESCRIPTION: Polypro® AH160 RENEWAL of this NOA shall be conside change in the applicable building code neg TERMINATION of this NOA will occur materials, use, and/or manufacture of the pr product, for sales, advertising or any other with any section of this NOA shall be cause ble rules and regulations governing the use of construction materials. ewed by the BCCO and accepted by the Building Code and Product de County and other areas where allowed by the Authority Having MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2.905 tion date stated below. The BCCO (In Miami Dade County) and /or the ty) reserve the right to have this product or material tested for quality ial fails to perform in the accepted manner, the manufacturer will incur ay immediately revoke, modify, or suspend the use of such product or serves the right to revoke this acceptance, if it is determined by BCCO requirements of the applicable building code. 1, and has been designed to comply with the 14 Velgcity tIurricane • ed after a renewal application has been tively affecting the performance of this • • • . • • • • . . fil pct ands here 4S,liigen no . Pr Sit. • ... • • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the j site at the request of the Building Official. This NOA renews NOA No.01- 0521.02 and consists of pages 1 through 7 The submitted documentation was reviewed by Jorge L. Acebo. ADVERTISEMENT: The NOA number receded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in adv literature. If any portion of the NOA is displayed, then it shall be done in its entirety. NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 1 of 7 • • • • • • fter the expiration date or if there has beer: a revion or tAlLfl . ge in tR duct or process. Misuse of this NOA as at: en‘iefsement'o't'any • urposes shall automatically terminate this N'OA. Iailura to comply for termination and removal of NOA. • ROOFING ASSEMBLY APPROVAL Category: Siib Category: Materials: SCOPE: This approves Polypro® A11160 as manu of this Notice of Acceptance. For the locat applicable building code, does not exceed t compliance with Roofing Application Stan profile roof tiles system using Polypro® moment based system for single patty plac PRODUCTS MANUFACTURED B Pr o duct Dimensions Polypro® AH160 N/A Foampro® RTF 1000 N/A ProPack® 30 & 100 N/A PRODUCTS MANUFACTURED BY Any Miami -Dade County Product Control list moment resistance values with the use o PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content Roofing Roof tile ad Polyurethan by accepted ASTM test methods a esive ctured by_Polyfoam Products, .Inc. as described in Section 2 • ns where the design pressure requirements, as determined by e design pressure values obtained by calculations in and RAS 127, for use with approved flat, low, and high 160. Where the attachment calculations are done as a ment, and as an uplift based system for double patty systems APPLICANT: Test Sp ecifications TAS 101 OTHERS: Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment • • • • • •• • • • ccepted Roof Tile Assembly having a cu. which; Polypro AH160 roof tile adhesive. • •••• •• •• est Result$ • • •• •• • • •• ' • • •• • AST D 1622 1.6 lbs. /ft,' AST 1) 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise AST D 1623 28 PSI Parallel to rise AST I D 2127 0.08 Lbs. /Ft AST E 96 3.1 Perm / Inch AST 1 D 2126 +0.07% Volume Change @ -40 F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks ASTM D 2856 86% Note: The physical properties listed abo e are presented as typical average values as determined d are subject to normal manufacturing variation. • • • • • • •••• • • •• • • • •••• •••• • • • •• • NOA No.: 06- 0201.02 Expiration Date: 05 /10/11 Approval Date: 04 /13/06 Page 2 of 7 EVIDENCE SUBMITTED: y Test AQenc Z --- --- o--- -. e t Identifier Center for Applied Engineering #94 -060 Miles .Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services LIMITATIONS: 2. Polypro® AI shall solely be used 3. Minimum underlayment shall be in cot 4. Roof Tile manufactures acquiring acce their tile assemblies shall test in accord 5. Roof Tile manufactures acquiring acce their tile assemblies shall test in accord F • 1�V F'= 2 MS 01 01 -6 70 52 5 5 5 5 5 5 52 2 7818 -IPA 5- 7438 -3 5- 7438 -4 5- 7438 -7 25 -7492 -589 -631 )637 -92 6743 -011 39- 062b[1] 0.02.96 -1 5 84 -2 -1 528454 -9 -1 454 -10 -1 0109 -1. 0109 -2 0109 -3 0109 -6 0109 -7 0191 -1 109 -2 -1 Test Name /Re TAS 101 TAS 101 SSTD 11-93 SSTD 11 -93 SSTD 11-93 ASTM D 1623 ASTM E 108 04/30/93 ASTM E 108 ASTM E 84 TAS 114 ort TAS 101 10/23/98 TAS .101 12/281,9$••• • • • •• • • Date 04/08/94 12/16/96 10/25/95 11/02/95 12/12/95 02/01/94 11/16/94 01/16/95 03/14/96 • • • • • •••• • TAS 101 • 9 7 • • • • 03/02/ • • • • •• •• •.•• • • •••• • • • • •••• I. Fire classification is not part of this ac eptance. Refer to the Prepared Roof Tile it for pre • • rating. •-• • • •• with flat, low, & high tile profiles. pliance with the Roofing Application Standard RAS 120. tance for the use of Polypro® A.H160 roof tile adhesive with nee with TAS 101. tancc for the use of HAN.DI -STICK roof tile adhesive with nce with TAS 101 with section 10.4 as modified herein. NOA No.: 06- 0201.02 Expiration Date: 05/10/1 1 Approval Date: 04 /13/06 Page 3of7 INSTALLATION: 1. Polypro® AH160 may be used with resistance values with the use of Pol 2. Polypro® AH160 shall be applied i corresponding Placement Details no the use of Polypro® AH160 shall pr based system, to meet or exceed the County Roofing Application Standa tile assembly NOA 3. Polypro® AH160 roof tile adhesive Roofing Application Standard RAS instruction and Maintenance Bookie 4. Installation must be by a Factory Tra Products, .Inc. Polyfoam Products In having jurisdiction. 5. Calibration of the Foampro® dispens The mix ratio between the "A" comp 1.15 (A): 1.0 (B). The dispense time determined at calibration. No other s 6. Polypro® AHl 60 shall be applied wi equipment only. 7. Polypro® AhI160 shall not be expose 8. Tiles must be adhered in freshly appli Polypro® A1-1160 has been dispensed 9. Polypro® AH160 placement and min Details' herein. Each generic tile pro • • Tile Profile Flat, Low, High Profiles High Profile (2 Piece Barrel) Flat, Low, High Profiles Flat, Low, High Profiles Plac D Table 1: Adhesive Pl, LABELING: All Polypro® AH160 containers shall co BUILDING PERMIT REQUIREMEN As required by the Building Official or appli installation of this system. any roof tile assembly having a current NOA that lists uplift ►.ro®AH160. compliance with the Component Application section and the ed herein. The roof tile assembly's adhesive attachment with vide sufficient attachment resistance, expressed as an uplift plift resistance determined in compliance with Miami -Dade ds RAS 127. The adhesive attachment data is noted in the roof nd its components shall be installed in accordance with 20, and Polyfoam Products, Inc. Polypro® AH 160 Operating ned 'Qualified Applicator' approved and licensed by Polyfoam . shall supply a list of approved applicators to the authority ng equipment is required before application of any adhesive. a nent and the "B" component shall be maintained between 1.0- shall be set to deliver 0.0175 to 0.15 pounds per tile as ttings shall be approved. h Foampro RTF1000 or ProPack® 30 & 100 dispensing permanently to sunlight. • • d adhesive. Tile must be set within 2 to.3 prinptes aftber • • • num patty weight shall be in accordanceiniLihe'Placement le requires the specific placement noted heveitt, • • • • •••• .• •• cement For Each Generic Tile Prong • • • ••• •• r 24 • N/A 8 ply with the Standard Conditions listed herein. S: able building code in order to properly evaluate the •• ment Single Paddy Two map Weight tail Weight Min. P P Y er addr Min • • • (grams) y " 35 nr�Os) ••• N/A 17 /side on cap and N/A 34 /pan •.' .• • NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 4 of 7 Nail through plastic cement Underlayment Nail through plastic cement U 1 Eave Course 10 in. Eave course only: Keep adhesive approx. 4 in. up from weepholes ADIIESI VE PLACEMENT DETAIL 1 SINGLE PATTY Fascia Weephole Eave closure Drip edge Underlayment 1 10 In Eave course only: Keep adhesive approx. 4 in. up from weepholes 1) Place enough adhesive to achieve 17 to 23 square inches In contact with the pan tile 2) Turn covers upside down. Place adhesive 1121n. To 1 in, From outside edge of cover tile. Then install the tile. Underlayment Nail through plastic cemonl Eave Course Remov lop portion of the eave course cover Ille. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line, Eave closure / Wee hole (mortar shown) p Fascia Boar Optional 2x4's for steep pitch applications Paddy (Beneath Tile) Nall through plastic cement • • • • ••• • •••• Opt %nal • • Point.uptartar • on longitudinal edges of file NOA No.: 06- 0201.02 Expiration Date: 05/10/11 Approval Date: 04/13/06 Page 5 of 7 • • Sheathing Underlaymen! Nail through plastic cement Eave Course Eave Closure Nail through plastic ce ent Underlayment 1. Eave Course Paddy(Benea Fascia Eave Course Paddy (Beneath Tile) Fascia Eave Closure Fascia • Weephole • !Mk closure �1rip edge ADHE ,IVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement 2 in. • Underlayment • • • •• •• Paddy (Beneath Tile) • • • • • • • • •••• •• •• •••• • • • • • • • • • • • •••• • • • • •••• • • • •• • •••• • • • NOA No.: 06- 0201.02 Expiration Date: 05 /10/1 1 Approval Date: 04/13/06 Page 6 of 7 • • • • • • • • • • • • • Nail through plastic cement Single paddy on top of tile Single paddy under tile Paddy (between til Pad (un 2in. I size paddy Fascia course onl Eave course medium ave Nail thr ugh plastic cemOr Single paddy under the ..4,..' , � r te` `_• J in. x3in. a paddy ' �� 4 '.• ` on underla \_�� yment Single Nd ■\ ` ` / �/ /' Eave Closure medum size paddy y eave Aiiii size paddy eave course only Fascia Eave Course Single paddy on under- layment Single paddy on top of tile Eave Course Single paddy under tile Single paddy between tile 2 in. x 7 in. medium size paddy eave course only Fascia Weephole Eat closure • • • t I • ADH END OF ESIVE PLACEMENT DETAIL 3 DOUBLE PATTY HIS ACCEPTANCE • • •••• • • • • • • • •••• •• •• • • •• •• • •••• • • •••• • • • • • • •••• • • • • •••• • • • •• • •••• • • • •. • NOA No.: 06- 0201.02 Expiration Date: 05/10/1 1 Approval Date: 04 /13/06 Page 7 of 7 • • • • • • ••• • • • • • • • • • • • DAVID A. DACQUISTO, AICP PLANNING & ZONING DIRECTOR DEVELOPMENT ORDER File Number: PZ06 -0125 - 02 Property Address: 9007 -9071 Biscayne Blvd Applicant: Ben Pumo (Owner) Address: 1500 NE 101 St. Miami Shores FL 33138 Agent: James D Obenour Address: 9301 NE 6 Ave. Miami Shores FL 33138 Land Sliorei ViLLcr�e 10050 N.E. SECOND AVE. MIAMI SHORES, FLORIDA 33138 - 2382 Telephone: (305) 795 -2207 Fax: (305) 756 -8972 Whereas, the applicant Ben Pumo (Owner) has filed an application for site plan review before the Planning and Zoning Board on the above property. The applicant sought approval as follows: Sec. 701: Appeal on allegation of error — Building material, surface colored not color through tile. Whereas, a public hearing was held on January 25, 2007 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Applicant to obtain all necessary building permits before commencing work. 2) Applicant to meet all applicable code provisions at the time of permitting. 3) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development Page 1 of 2 order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. 4) Applicant will replace tile within six (6) months of notice by the Planning Director that the tile color has faded or the surface damaged so as to expose the base color of the tile. Additionally, the applicant must, satisfy all applicable Miami Shores Village Codes, Miami -Dade County Codes, the applicable building and life safety codes required for development, and provide a copy of the development order to the Building Dept. The application with conditions was passed and adopted this 25` day of January, 2007 by the Planning and Zoning Board as follows: Mr. Abramitis Yes Mr. Ulmer Yes Mr. Reese Yes Mr. Sastre No Chairman Fernandez No Date Ch<'rman, Planning and Zoning Board Page 2 of 2 v BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. r Ben %um° Date . A N 2 Street • ~ Al SE Owners Name and Address — _.... Registered Architect and /or Englncer y N. �Y1�ff 7�tf{ r ,•. -,, ,,,. .. Name and address of licensed contractor Obenowt. POO nQ. C°• 7357 N. W. Location and legal description of lot to be built on: 44 Lot Block _ . r5oo b: isi9�r se Street and Number where work is to be done State work to be done and purpose of building (by floors) '9 Ludvtuice New Building Remodeling. Addition To be constructed of Kind of foundation Estimated Total cost of improvements $ • Disapproved (Signed) MIAMI SHORES VILLAGE Date Member Member Member Member Council Approved (Signed) , PLANNING BOARD DATE Chairman Member e.Cdvn c.Catf and for no other purpose. Repairs X No of Stories Roof Covering 78 Amount of Permit $. 22.00 Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under theFlorida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to bg performed under this pernit, as are licensed by Miami Shores Village. Remarks STATE OF FLORIDA, COUNTY OF DADE. j ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No.._. � ._4.0 9_j Date C t. — 1 � — !2 0 Read, Sworn to and Subscribed before me. Notary Public, State of Florida ui ding Inspector My Commission Expires to me well known, Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has hero obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection oe faulty materials and /or workmanship. Application is hereby umde for the appro\al of the detailed stateiuent ur me plans and specifications herewith submitted for the build ire or other structure herein described. This application Is made in compliance and conformity with the Building Ordinance of Miarni Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A cupy of approved plans and specifications must be kept at building during progress of the work. Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivision . Remarks (Signed) STATE OF FLOEIDA, COUNTY OF DADE. j ss. by stated Perrrut No •�/ ! �! Date 11)5)/9 Budding Inspector Chairman Nfcrmbcr ,Member .. Council Approved Date MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Disapproved... s Date (Signed) te r/ Date..._....., _.?._ 9 ,19.71_ p Owner's Name and Address ! &' Q _ No. .:� QQ.._... Street...... fir Add Registered Architect and /or Engineer ,., rz.c2.4 %o .lk .... ''r / 'U� r c �? r" G goy .�. w, 4/t .O Al Street and Number where work is to be done /. ) E_..l..a./ �- State work to be done and purpose of building (by floors) ./. fC/'1O/,Je O. ‘''P ; -77Z. ; 30 °P°` 9 _ .as7�d ....774.-;. _ 30 sb f1/0 .e ....:..Q� _._ S- /°/°4� g " -"O./N.?' 67. 00P/e �,Y s _ r , Y and for no other purpose. Ncw Building Remodeling '�_ Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering .. 1.. .. Estimated Total cost of improvements $ Q: Amount of Permit 5�..I J!. Q.G!_ Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to. The umlersigncd applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Honda Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on th ' of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors, • . work • be performed under this permit, as are licensed by 'Miami Shores Village. PLANNING BOARD DATE Read, Sworn to and Subscribed before me. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein b hi m tate d are true. Notary Public, State of Florida My Commission Expires Member Member Member Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained term tirc I lannir,;; Ito.rrd. A re inspection Ice of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. TO nl ano II Miami Shores Planning & Zoning Board 10050 N. E. 2nd Avenue Miami Shores, Florida 33138 Gentlemen: I wish to apply for a special exception to Ordinance #403 -78 which will allow me to install a Cedar shake r oof �o'nimyy residence located at 1500 Northeast 101st S BP /ja December 5th, 1979 Sincerely, Ben Pumo 7327 N.W. MIAMI COURT MIAMI, FLORIDA 33150 TELEPHONE 757 -1823 Mr..A. J.. Barranco, Jr. 310 Concord Building_ 66 'West Fl agi er Street Miami ,,Florida 33130 Dear A.J.: Enclosed is the 'requested,informatiori pursuant to your request. of November 26, 1979: • Please send to the Village S1 /..00 to cover copying OSA:v Enc. Very truly yours, 0. Sam Ackley Village Manager Ben nl uuno II November 1st, 1979 Miami Shores Village Planning & Zoning Department 10050 N. E. 2nd Avenue Miami Shores, Florida Gentlemen: I wish to request a variance of Ordinance # 403 -78. It is necessary to replace the present roof at my residence, 1500 N. E. 101st Street and I would like to use thick butt, hand split, fire retardant treated, cedar shakes. If needed, further specifications on the shakes are available. Your cooperation is appreciated. Si ly, Ben Pumo BP:me 7327 N.W. MIAMI COURT MIAMI, FLORIDA 33150 TELEPHONE 757 -1823 NAME Ben Pumo Building Corp. 3 . 7 & 6 - 8 . / Q 10. INDUSTRIAL PROPERTIES FOR LEASE 7327 N. W. MIAMI CT. MIAMI, FLORIDA 33150 757 -1823 NOVEMBER 16TH, 1979 WE THE UNDERSIGNED HAVE NO OBJECTION TO THE INSTALLATION OF A FIRE RETARDED, HAND SPLIT, THICK BUTT CEDAR SHAKE SHINGLE ROOF ON THE RESIDENCE OF MR /MRS B._PUMO LOCATED AT 1500 NORTHEAST 101 STREET. THE INSTALLATION SHALL MEET OR EXCEED ALL STANDARDS KNOWN FOR THIS TYPE OF ROOF. INSTALLATION SHALL BE UNDER THE DIRECTION AND APPROVAL OF WAHL SNYDER, ARCHITECT. ADDRESS DATE i Si/ ivz /7/ S /4 Loia Wu/ /o/ /,,fr /1 70/ J` Nc �� 07 --ex - 27 37% /(-23-27 7 / -- Jr3 - 7y 7 5 R 3S 3o.l /V6MV5. 4 31 • MA 32. S6?/L 36. 37. 38. NAME 39. 4Ci 43. 45. 46. 41 %1 . ; 42. do az-v-L. . > I 4-9 ADDRESS DATE I210 NE IoaS÷. j a2s4/. tp-.5y 7), .,/D/a iL,lr /V3/ N/r /Ir2 /44> a �i - 7 - -77 il-a9r- 7y /- / 1- 72 /4- /-7 11. 12. 16.E 17. p ,; VU/ 18. 19. 20 21. NAME . ADDRESS /N6 o Vg /o/ , }19 A / / 6 / s� 1310 S-r /3 k ,1 . ( C l I /36''d /( /E /or 5 /a.go Y1.� /oa DATE // z -rh 7 R ) -'1.9 /r // -2 6 -, 79 MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address.___.... e 4 - 1.7.1.Z_l11.p Registered Architect and /or Engineer Date Name and address of licensed contractor.. Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done / (1 (i , e State work to be done and purpose of building (by floors) 1s 4 , `7 No / 5 i 9 Street l �� and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundatie Roof Covering / r Estimated Total cost of improvements $ / 7 Amount of Permit $ Zone cubage required _Plan Cubage Distance to next nearest building. Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub .ntractors, on work to be . rformed under this permit, as are licensed by Miami Shores Village. Remarks ( Signed). STATE OF FLORIDA, COUNTY OF DADE. J ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared , to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No Date 10 ` Read, Sworn to and Subscribed before me. Disapproved /� -- - Notary Public, State of Florida (Signed) co) / �.� - -- - ...._._.... .�—�.� Building I ector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member ... Member _ Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. BUILDING ELECTRICAL PLUMBING ROOFING MIAMI SHORES VILLAGE. FLORIDA ❑ DATE 195 7 ❑ PERMIT N° 6237 Contractor's License No. ❑ Work to be performed under this Permit Owner of Building K p- a .., Architect Contractor or Builder ,';a 6, t e;_ Pt rh �`� Legal Lot Description — 1 Bl Address of Building # :`y _ i, Ii.' c Subdi- vision Value of 1 Amount of Project $ 1 Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further. condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the ements or specifica ' ns and twat he assumes responsibility for work done by his agents, servants or employees. Signed. Le) P 14- INSPECTOR ��> In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinaiw2s and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or / specifications ,puubmitted to the proper authorities of Miami Sho Village. In ac- cepting th' permit I assume responsibility--for all work done by either, myself, thy agent, servant or employee. C TRACTOR OR BUILDE{l BY • BY AUTHORITY 6 BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Description Address of Building PERMIT N° 2442 LJ Lot MIAMI SHORES VILLAGE. FLORIDA This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Work to be performed under this Permit B1 Signed - INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR OR BUILDER BY AUTHORITY 64635° Value of Project $ DATE__ 195 Contractor's License No. Subdi- vision 11 Amount of Permit $ BY