Loading...
320 NE 100 St (5)PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date )- d Job Address 3.}Z2 1.9.a • i OO 57• Tax Folio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant -- � F s Pb lam. APPROVED: Zoning Mechanical Square Ft. Estimated Cost (value) 8 Signature of owner and/or Condo President Notary as to Owner and/or Condo President My Commission Expires: Date Signa o Owner- Builder Date Notary . -: o Contractor or My Commission Expires: Master Permit # 7 7 /P &) 4/7y 08 Owner's Address ,{ Phone Contracting Co. K. �t _ �- . (� J t � c l I oFc (a C. Qualifier -krJ1-1 ( Pot J A. 2{ S SS# (Rhone 70 / -3 7-gig/ / State # £ L7 � - ' Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Address i S I 1.v Permit Type (circle one): BUILDING ELECT CAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION b WA E1 l% 1 J '2 ` �/ ( P to / WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stat Dat -T- oe''- c oar/ d ARY SEAL weer a ut ffiIDYS I VIL ' NarARY PUBLIC 51 ATE OP FLORIDA COMMIS%ION NO. CC714103 MY CO MMSStON EXP. MAR. 1 2121Y2 FEES: PERMIT V RADON C.C.F. )/7 NOTARY ) BOND TOTAL DUE Building • I T ( $ Electrical Plumbing Structural Engineer METRO -GADS PRODUCT CONTROL NOTICE OF ACCEPTANCE Clopay Corporation 312 Walnut St., Suite 1600 Cincinnati OH 45202 Your application for Product Approval of: 2" EPS Sectional Door 9' Wide under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted bv: Applicant, along with Clopay Building Products Co. drawing # 101703, last revision on 07/08/95, signed and sealed by M. W. Westerfield P.E. (For compere rising, see Section i has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting, this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:97- 0124.02 (Revises No.: 95- 0316.11) Expires:08 /21/00 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved: 08 /21/97 Internet mail address: postmaster @buildingcodeonline.com METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 - 1563 (305) 375 -2901 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Raul Rodriguez Product Control Supervisor Director Building Code Compliance Dept. Metropolitan Dade County Homepage: http : / /www.buildingcodeonline.com Track Skin End Stile Center Stile End Hinge Center Hinge Horizontal Reinforcement Shape Frequency 16 GA Double 27 GA 18 GA N/A 14 GA 18 GA 3" x 20 GA. U 2 /Section Clopay Corporation ACCEPTANCE NO: 97- 0124.02 APPROVED : AUG 2 1 1997 EXPIRES : AN 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1.0 DESCRIPTION: This approves sectional door 9' -0" wide x 8' -0" through 6' -6" high made out of steel, drawing quality Grade 26,000 PSI (ASTM A528) galvanized coating of G6n (ASTM A525) finished with baked on polyester coat. The door shall be constructed and reinforced as detailed in the approved drawing #101703 2.0 USE: This door is approved for a maximum design pressure of +48PSF and —60PSF and its use is restricted to this pressure. The door passed the impact and cyclic test; therefore it does not require hurricane protection devices. The door shall meet the burglary security requirement of section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not included in !his approval) shall be certified by Underwriters Laboratories or other recognized agency. Candido Font, PE, Sr. Product Control Examiner Product Control Division Clopay Corporation ACCEPTANCE NO: 97- 0124.02 APPROVED : AUG 2 1 1997 EXPIRES : AUG 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 3.0 INSTALLATION: The door shall be installed as shown on Drawing 4101703. Wood in contact with concrete or cement shall be treated with an approved preservative as set forth in paragraph 2913.2(a)1 or shall be of a durable species as defined in subparagraph 2913.2(a)6(aa) of the South Florida Building. Code. Installation of 2" x 6" wood jamb required a' /4" x 31/4" ITW tapcon and 1"0 x 1/16" thick washer 8" from bottom & 16" o/c with a minimum embedment of P/4" into 2000 PSI (minimum) concrete or grout filled concrete block or 3/8" x 4" Rawl lok/bolt and 1" 0 x 1/16" thick washer @ 8" from bottom & 24" o/c with a minimum embedment of 1' /" into 2000 PSI (minimum) concrete or grout filled concrete block. Installation of track requires a 5/16" x 1 wood lag screw at each track and flag bracket as shown on Drawing #101703 with a minimum embedment of 1- 1/16" into 0.55 SG Southern Yellow Pine PT 2" x 6" wood jambs. 4.0 CONDITIONS OF USE: Application for Building permit shall be accompanied by duplicate prints of the approved Drawing 4101703 bearing the approval stamp, Notice of Acceptance number and date by the Dade County Product Control Section along with computations prepared by a qualified Florida Professional Engineer or Architect verifying the adequacy of the door at each site. The shop drawing shall bear the signature of the Architect or Engineer with the following statement "The supporting structure has been designed for the forces shown on the approved manufacturer's drawing. Application for building permit for replacement doors shall be accompanied by duplicate prints of the approved Drawing 4101703 bearing the approval stamp. Notice of Acceptance number and date by the Dade County Product Control Section. Also the building official must be satisfied that the proposed installation meet the use of Section 2 above. -2a- Candido Font. PE, Sr. Product Control Examiner Product Control Diyision Clopay Corporation ACCEPTANCE NO: 97- 0124.02 APPROVED : Al1G 2 1 1997 EXPIRES : All6 2 1 2000 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 5.0 LIMITATIONS: This approval requires the manufacturer to do testing of all coils used to fabricate door panels under this Notice of Acceptance. A minimum of 2 specimens shall be cut from each coil and tensile tested (according to ASTM E -8) by a Dade County approved laboratory selected and paid by the manufacturer. Every 3 months, four times a year, the manufacturer shall mail to this office: a copy of the test reports with confirmation that the specimens were selected from coils at the manufacturer's production facilities and a notarized statement from the manufacturer that only coils with a yield strength of 26,000 PSI or more shall be used to make door panels for Dade County under this Notice of Acceptance. 6.0 IDENTIFICATION: All approved products shall be permanently labeled with the manufacturer's name, city, state and the following statement: "Dade County Product Control Approved ". 7.0 EVIDENCE SUBMITTED: Test Report Test Date Signature CTL 4986B ASTM E -8 12/16/96 R. Patel, PE ATE #1112.02 -96 PA 201, 202 R. 203 11/14/96 W. Mehner, PE Calculation Date Mark Westerfield 01/10/97 Drawing Number Clopay B.P. Co. 101703 - 2b- Signature M. W. Westerfield, PE Last Revision 07/08/97 Signature M. W. Westerfield, PE ndido Font, PE, Sr. Product Control Examiner Product Control Division Clopay Corporation ACCEPTANCE NO : 97- 0124.02 AUG 2 1 1997* EXPIRES : AlIG 2 1 NOTICE OF ACCEPTANCE STANDARD CONDITIONS APPROVED Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer, who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering professions. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The engineer need not reseal the copies. 3. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2 (b) and this last page 3. Items 1 0 , I 1 & 12 listed below only apply to glazed products 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section I I. The spacing of fasteners at windowsills shall be as indicated in Section 4 of this Notice of Acceptance. The spacing of fasteners in all other parts of the frame shall be as indicated in Section 4 of this Notice of Acceptance, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the sane size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. 12. Hardware for all windows and doors shall conform to Security and Forced Entry Prevention, Chapter 36 of the South Florida Building Code. Candido Font, PE, Sr. Product Control Examiner Product Control Division END OF THIS ACCEPTANCE -3- INSTALLER MODEL RETAIL MODEL DESCRIPTION 4200 2200 24 GA EXTERIOR SKIN; TRADITIONAL R/JSI D PANEL 4300 HDG 2300 27 GA. EXTERIOR SKIN; ELEGANT RAISED 'ANEL 4400 2400 24 GA. EXTERIOR SKIN; ELEGANT RAISED 'ANEL 4401 2201. 2401 24 GA. EXTERIOR SKIN; FLUSH PANEL 4301 2301 27 CA. EXTERIOR SKIN; FLUSH PANEL 4310 N/A _ 25 GA. EXTERIOR SKIN; RAISED WIDE FANEL DOOR HEIGHT "L BRA 4 P .0 31 .11. X1 ���� WA big [ 5iQJi ®E_4iiii IMIN ILEEdlFla/l JE4IQiElmII I 8 ' -• ®1.11111A `�QM MODELS 2200. 2201. 2300. 2301, 2400. 2401. 4200. 4300, 4301. 4310 4400. 4401. HDG REINFORCEMENT PLATES ATTACHED TO DOOR SKIN WITH PATENTED TOG -L -LOC SYSTEM (NOT VISIBLE FROM OUTSIDE) (2) INTERMEDIATE REINFORCEMENT PLATES PER SECTION ATTACHED WITH TOG -L -LOC SYSTEM (NOT VISIBLE FROM OUTSIDE) - A MAX. DOOR WIDTH - 9' 0" INSIDE ELEVATION LOCATION OF OPTIONAL VENTS V A•F 0 P1%3 AILS ra GO VS, 1%.4 • NOTE 1; DOORS 6'6' HIGH CONSIST OF (4 SECTIONS; (2) OF 21" & ( 2) OF 18". DOORS 7'0' HIGH CONSIST OF r (4 SECTIONS; 4 OF 21 . DOORS 7'6' HIGH CONSIST OF 5 SECTIONS; 5 OF 18" . DOORS 8'0' HIGH CONSIST OF 5 SECTIONS; 2 OF 21" & (3) OF 18'. NOTE 7; SUPPORTING STRUCTURAL ELEMENTS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER FOR WIND LOADS SHOWN ON THIS DRAWING. X4' X3' "X2" 1 13 GA GALV. STEEL FLAG BRACKET. EACH FASTENED TO WOOD JAMB WITH (3) 5/16"x1 -5/8" WOOD LAC SCREW.. TRACK CONFIGURATION 2" GALV. STEEL TRACK. TRACK THICKNESS: .060" TWO POINT LOCKING INTO TRACK PER SFBC 3603.2. 5/8• MIN. ENGAGEMENT (OPPOSITE SIDES OF DOOR) (SEE LOCK OPTIONS) HORIZONTAL TRACK SUPPORT BY DOOR INSTALLER (TO SUIT) TYP. 2 -1/2 "x12 GA GALV. STEEL TRACK BRACKET. b 0 1 0 0 0 W In o 0 0 REINFORCEMENT PLATES ATTACHED TO DOOR SKIN WITH PATENTED TOG -L -LOC (NOT VISIBLE FROM OUTSIDE) (2) INTERMEDIATE REINFORCEMENT PLATES PER SECTION. ATTACHED W/ T0;- I. -LOC SYSTEM (NOT VISIBLE FROM OUTSIDE) 2x6 WOOD JAMB MAX. DOOR WIDTH - 9' 0 • INSIDE ELEVATION LOCATION OF OPTIONAL VENTS END STILE PREPARATION OF JAMBS BY OTHERS SUDE BOLT LOCK ENGAGES INTO VERTICAL TRACK. ONE LOCK ON EACH SIDE OF DOOR. INSIDE SUDE BOLT LOCK OPTION 12 C.A. GALV. STEEL TRACK BRACKET FASTENED TO WOOD JAMB WITH ONE 5/16' x1 -5/8' WOOD LAG SCREW PER BRACKET. / 2" GALV. STEEL TRACK - FASTENED TO TRACK BRACKETS. EACH BRACKET ATTACHED dWNU ONE NUT TWO 1/4' RIVETS. - A JAMB CONFIGURATION 2" STEEL ROLLER. OUTSIDE HANDLE SEE END UWCE DETAIL SEE INTEF. H NGE DETAIL TWO POIN LOCKING INTO TUCK PER SFBC X605.2. 5/8' IIIN. ENGAGEMENT (OPPOSITE SIDES OF DOOR) (SEE LOCI: OPTIONS) OUTSIDE KEYEG.1 LOCK BAR Loma THE 2x6 VERTICAL WOOD JAMBS ARE TO BE GR/DE 2 OR BETTER YELLOW PINE. NO LOAD IS IRAN STIRRED TO THE HORIZONTAL (TOP) JAMB. ALL JAMB FASTENERS MAY BE (BUT NOT REQUIRED) COUNTERSUNK TO PROVIDE A FLUSH MOUNTING SURFACE. STOP MOULDING BY DOOR INSTALLER (TO SUIT) 18 GA. GALV. STEEL END STILE (END STILES HELD BY HINGE :'.Cf EWS) END STILE .-LOCK BAR GUIDE OUTSIDE ----- KEYED HANDLE LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR. 18 GA. MIN. GA LV STEEL CENTER HINGE FASTENED TO INSIDE SKIN W /(4) EACH 14x3/8" `_'HEFT METAL SCREWS 14 GA. GALV. STEEL END HIN•;E FASTENED TO ENO STILES w /;4) EACH #14x5/8' SHEET METAL SCREWS AND (4) 1/4'x5/8" SELF TAPPING S. :REWS. SNAP LATCH ENGAGES ONTO VERTICAL TRACK. ONE SNAP LATCH ON J EACH SIDE OF DOOR../ "—END STILE INSIDE HANDLE OUTSIDE KFYFTI LOCK SNAP IATCH LOCK OPTION 27 GA. MIN. EXTERIOR STEEL SKIN (MIN. YIELD STRENGTH: 26 KSI, DRAWING QUALITY) WITH G -60 GALV., BAKED -ON POLYESTER PAINTED TOP COAT APPLIED TO BOTH SIDES OF STEEL SKIN. 14 CA END HINGE TONGUE AND GROOVE JOINTS. (4) #14x5/8" SHEET METAL SCREWS (4) 1/4 "x3/4" SELF TAPPING SCREWS 2x6 WOOD JAMB CAN BE ANCHORED TO GROUT REINFORCED BLOCK WALL OR CONCRETE COLUMN. BLOCK CELLS SHALL BE FILLED WITH CONCRETE AND REINFORCED WITH CONTINUOUS #5 BAR EXTENDING INTO THE FOOTING AND INTO TIE BEAMS. ANCHORS CAN BE 1/4 "x1 -3/4" EMBED TAPCON CONCRETE ANCHORS STARTING AT NO MORE THAN 5" FROM BOTTOM AND 16" 0.C.. Q$ WITH 3/8"x4" (1 -3/4' EMBED) RAWL LOK /BOLT ANCHOR STARTING AT NO MORE THAN 8" FROM BOTTOM AND 24' 0.C. DESIGN ENGINEER: MARK W. WESTERFIELD FLORIDA REGISTRATION No. 48495 MECHANICAL ENGINEERING r Clopay Building Products Company SIUCONE FILLED CHANNEL SEPARATES FRONT AND BACK SKIN OF DOOR / — 2' THICK 14 GA. GALV. STEEL END HINGE. EACH FASTENED TO END STILES iii /(4) #14x5/8" SHEET METAL SCREWS AND (4) 1/4'x3/4" SELF TAPPING SCREWS \- 13 GA GALV. STEEL BOTTOM BRACKET. ATTACHED WITH (2) #14x5/8" SHEET METAL SCREWS. ALUMINUM EXTRUSION & VINYL WLA1HERSTRIP. 18 GA INTERMEDIATE HINGE 14 GA. INTER. HINGES USED ON 24 CA. EXTERIOR SKIN DOOR MODELS CLOPAY BUILDING PRODUCTS COMPANY 312 WALNUT STREET SUITE 1600 CINCINNATI, OHIO 45202 (513) 381 - 4800 12 GA. GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W /(4) #14x5/8" SHEET METAL SCREWS. SECTION A -A 1.95" THICK, 1# DENSITY EXPANDED POLYSTYRENE FOAM INSULATION LAMINATED (SUPPUED BY FACLON MANUFACURINC) TO BOTH EXTEROIR AND INTERIOR SKINS. 3" TALL x 20 GA GALV. STEEL U -BAR. TWO PER DOOR SECTION. ATTACHED WITH (6) 1/4'x3/4" SELF TAPPING SCREWS PER U -BAR. (2) ON EACH END & (2) AT CENTER HINGE LOCATION. 27 GA INTERIOR STEEL SKIN (DRAWING DUALITY) WITH G -60 GALV., BAKED -ON PRIMER AND A UAKED-ON POLYESTER PAINTED TOP COAT APPUED TO BOTH SIDES OF STEEL SKIN. DESIGN 1GADS: +48.0 PSF & —60.0 PSF. TEST L, ?DS: +72.0 PSF & —90.0 PSF. PLOT 1.42 rn 11119/96 - r«n..T WAN o.ra®. . APPROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DAT . --�•-. 19CM BY �J■ UC DIVISION BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE NO.'11 - 612 1 4.8Z cv.uvrsio. 11�ibiF� - tt�f. 9'0'W x 8O"H °�"°' 22 00/01. 2400/01. ' HDG, 4200 4300/01 4310 4400 /0t /1/ i/Tjf