258 NE 100 St (8)PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 1 0 -3 l - 00 Job Address a 5 8 NE 100 *' 57 Tax Folio
I, �.�/ �
Legal Description /457 5 t c. • 1 11 Cot COT 6 iStAliifol'1'cally Designated: Yes No
Owner/Lessee / Tenant 1`O f-f' Sammons + Arne W e n n e S
Owner's Address a s T NG- )00
Contracting Co. Pe , r ) � 'P i lt 'C e- -L/' 7C Address 39 ) 51,t> c ' .4 ta2 1l..r/A r
Qualifier p• . Y 1 ! )0 l l SS # Phonec644
State # Municipal # Competency # q ��) 3( (.54ns. Co.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING ENC SIGN
WORK DESCRIPTION 19I7C • 1 b0 / D g w - 7 w w d - Fez - I C ,
Square Ft. Estimated Cost (value) 4 1 �d)
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER
OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work
will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL
PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Furthermore, I authorize the above -named contractor to do the work s tilljt�
Signahke of owner and/or Condo President Date
•ti .. ;% •Milagros Rodriguez
� . Commission # CC 912524 n }1%�
s - ., '. Expires Feb. 27.2004 /a /3a U�/
Notary as tO'A', a fiti8Aorndirg�o.etna Date
My Conunission Expires:
60
FEES: PERMIT
APPROVED:
n
Zoning ( / l i t �� Building
RADON
C.C.F.
Master Permit #
Phone 30 5 7 - I .)-17
lolW /C0
Sign ge of Contractor or Owner - Builder
-. z �,'. ilagros Rodriguez
+� ._ P:= # CC 9I�
.- - i;xpi S24 Date
Notary as �ctor or � t�i1ag64
My Commission ExiVeRtic Bondin Co., I nc.
Electrical
grar
NOTARY — D - BOND
TOTAL DUE
l
Date
Mechanical Plumbing Structural Engineer
PERMIT NO. -
ADDRESS: .
MIAMI SHORES VI LLAGE
BUILDING / ZONING DEPARTMENT •
SECTION
BY
DATE
ZONING
ELECTRICAL •
MECHANICAL
PLUMBING
FIRE
PUBLIC WORKS
STRUCTURAL
BUILDING OFFICIAL
1. Subject to compliance with ett Federal. State,
County, Village rates tad mutations. Village assumes
no responsibility for accuracy of /or results scow
these plans.
2. This copy of plans meat be available ors
bultding site or no Inspection will be conducted.
JOB ADDRESS .2. S ' � ` /00 S7
APPLICANT g06 ?. S4,r , OnS /41 it 47
PHONE t#
APPUCA11ON ## 6-�. Y S f vt/C
SHEET OF
MISCELLANEOUS
DATE
CRITIQUE SHEET
2 /1 //tIG
I 5
6
COMMENTS
// V / o /7 Y,1,
'4 asr /,"-e -ova 4 #4,57 rUAri6,
26/V /,/6 4:5470
5�-�- , 9r74 - ch 42 rito /*6
� C6 • Q
INITIALS
V
Fnd.
vePipe
(N&N)
0
Fnd.
r Pipe
(N&N)
0
SKETCH OF BOUNDARY SURVEY
SCALE: 1" =
23' Grassed Parkway
P. Line /No.-
If
.,7 .0 (M&R).......
0' Asphalt Pavement
tras
BEARD:GS SHOWN HEREON (IF ANY) ARE REFERED TO AN ASSUMED MERIDLAN OF
2
Lot 4
K b
Fnd.
e Pi e
(NJ)
1 .0' cl
iLi
Blk
Corn
203.0'
0
C.L.Fence
Fnd.
1/2-Pipe
(N&N)
FOR THE CENTERLLNE OF
< X
s -
PIT/Po Afe
-z,oN 'PAP
porell •
LEGAL DESCRIPTION:
ION:
LOT ANP E= 4.s-'r 44�1 =f of L°T (o . BLOCK ' 3
Mi AM i L.lot SEcTioN. Owe SUBDIVISION
ACCORDING TO THE PLAT THEREOF AS RECORDED IN THE PLAT BOOK 10 AT PAGE 7O
OF THE PUBLIC RECORDS OF DADS COUNTY, FLORIDA.
N
CERTIFIED TO:
(IF ANY
ABREVIATION
E • CENTER UNE
t • PROPERty LJE
Rill • RIGHT OF WAY
C.Lf. • MAIN LINK FENCE
W.F. • IOCDEN FENCE
RES RESNDfNCE
F.N.D. • FOUFC IRON PPE
S.R.B. ■ SET REBAR
C.B. - CMNORD SEARING
NEAS.(N) - ►EILSURED
S.N.JO. SET HAL AND OISC
ci+
40'
40'
DATE OF FIELD SURVEY:
11 12
13 1
$ 14
30 '
15'
15'
N.E. 100th STREET.
—
15
50'
A�2iL
ID OA
APPUED)
CL - CLEAR
ENC. - ENCROACNIENT
C.B.S. - CONCRETE BLOCK STRUCTURE
co NC • CONCRETE
0 • DuN,ETER
ORANACE MANT. EASEMENT
S.I.W. - SET PON PPE
F.0.14. • FOUND DRILL HOLE
A/c • NR OOFQD UPC
REC. (R) • RECORDED
F.N.O. - FOUND NAL AND DISC
16
LOCATION MAP
NO TO SCALE
17
18
Q
19
N.E. 99th STREET.
ADDRESS: 2 N. E • 100 41" sT Ivt 1A/•-41 S40'1:2.E
JOB NUMBER: c — 47 FL.
20
50'
21
22
9
R
23
53.1
R
30'
30'
Tid
LJ
Z
Robert R. Sammons and Anne M. Mennes, his wife
First Residential Mortgage Company, its successors and /or assigns, ATIMA
Spieler and Associates, P.A.
Attorney's Title Insurance Fund, Inc.
WE HEREBY CERTIFY THAT THE ATTACHED SKETCH OF BOUNDARY SURVEY OF THE ABOVE DESCRIBED PROPERTY IS A TRUE AND CORRECT
REPRESENTATION OF A FIELD SURVEY MADE UNDER MY SUPERVISION AND MEETS THE MINIMUM TECHNICAL STANDARDS, AS SET BY THE FLORIDA
BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS, IN CHAPTER 61G 17.60F THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION
472.027, FLORIDA STATUTES.
American Services of Miami, Corp.
ENGINEERS - PL . NERS - LAID SURVEYORS
2450 S.W. 137th Ave., Suite 217. Miami. FL 33175
Phone: (305) 554.6963 Fax: (305) 554 -7516 LB 6683
REVISION DATE:
SURVEYOR'S NOTES:
- EXAMINATION OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY AFFECTING THIS PROPERTY
-SHOWN ELEVATION ARE BASED ON N.G.V.D. (NATIONAL GEODETIC VERTICAL DATUM OF 1929) -LEGAL DESCRIPTION WAS PROVIDED BY THE CLIENT
•NO UNDERGROUND UTILITIES OR IMPROVEMENTS HAVE BEEN LOCATED, EXCEPT AS NOTED.
-THERE ARE NO VISIBLE ENCROACHMENTS OTHER THAN THOSE SHOWN.
WILSON DE LA 1 ORRE
PROFESSIONAL LAND SURVEYOR
AND MAPPER No. 1870
STATE OF FLORIDA
U.E. - uTL. EASEMENT
11 • MONUMENT LNE
P.C. • PONT OF cuRvATURE
►.H. - FIRE HYDRANT
CASIO. • EASLNENT
S.D.H. - SET ORLL HOLE
CALC.(C) • CALCULATED
F.S. • FOUND SPRCL
RAO. • RADIAL
P.O.B. - PgHT of BEGINNING NOT VALID UNLESS SEALED WITH AN EMBOSSED SURVEYOR SEAL
P.O.0 • POINT OF CURVATURE
DATE: t*pa. j . l6 Ic)S S
....:r .Y... . f .IC:—: K« •..d aL•!! ...1 j• ,...d -' ../...dr d
50'
50'
50'
50'
50'
k .au
r
Qf
.ON
8
7
\ \` All
4
3
2
LEGAL DESCRIPTION:
ION:
LOT ANP E= 4.s-'r 44�1 =f of L°T (o . BLOCK ' 3
Mi AM i L.lot SEcTioN. Owe SUBDIVISION
ACCORDING TO THE PLAT THEREOF AS RECORDED IN THE PLAT BOOK 10 AT PAGE 7O
OF THE PUBLIC RECORDS OF DADS COUNTY, FLORIDA.
N
CERTIFIED TO:
(IF ANY
ABREVIATION
E • CENTER UNE
t • PROPERty LJE
Rill • RIGHT OF WAY
C.Lf. • MAIN LINK FENCE
W.F. • IOCDEN FENCE
RES RESNDfNCE
F.N.D. • FOUFC IRON PPE
S.R.B. ■ SET REBAR
C.B. - CMNORD SEARING
NEAS.(N) - ►EILSURED
S.N.JO. SET HAL AND OISC
ci+
40'
40'
DATE OF FIELD SURVEY:
11 12
13 1
$ 14
30 '
15'
15'
N.E. 100th STREET.
—
15
50'
A�2iL
ID OA
APPUED)
CL - CLEAR
ENC. - ENCROACNIENT
C.B.S. - CONCRETE BLOCK STRUCTURE
co NC • CONCRETE
0 • DuN,ETER
ORANACE MANT. EASEMENT
S.I.W. - SET PON PPE
F.0.14. • FOUND DRILL HOLE
A/c • NR OOFQD UPC
REC. (R) • RECORDED
F.N.O. - FOUND NAL AND DISC
16
LOCATION MAP
NO TO SCALE
17
18
Q
19
N.E. 99th STREET.
ADDRESS: 2 N. E • 100 41" sT Ivt 1A/•-41 S40'1:2.E
JOB NUMBER: c — 47 FL.
20
50'
21
22
9
R
23
53.1
R
30'
30'
Tid
LJ
Z
Robert R. Sammons and Anne M. Mennes, his wife
First Residential Mortgage Company, its successors and /or assigns, ATIMA
Spieler and Associates, P.A.
Attorney's Title Insurance Fund, Inc.
WE HEREBY CERTIFY THAT THE ATTACHED SKETCH OF BOUNDARY SURVEY OF THE ABOVE DESCRIBED PROPERTY IS A TRUE AND CORRECT
REPRESENTATION OF A FIELD SURVEY MADE UNDER MY SUPERVISION AND MEETS THE MINIMUM TECHNICAL STANDARDS, AS SET BY THE FLORIDA
BOARD OF PROFESSIONAL LAND SURVEYORS AND MAPPERS, IN CHAPTER 61G 17.60F THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION
472.027, FLORIDA STATUTES.
American Services of Miami, Corp.
ENGINEERS - PL . NERS - LAID SURVEYORS
2450 S.W. 137th Ave., Suite 217. Miami. FL 33175
Phone: (305) 554.6963 Fax: (305) 554 -7516 LB 6683
REVISION DATE:
SURVEYOR'S NOTES:
- EXAMINATION OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY AFFECTING THIS PROPERTY
-SHOWN ELEVATION ARE BASED ON N.G.V.D. (NATIONAL GEODETIC VERTICAL DATUM OF 1929) -LEGAL DESCRIPTION WAS PROVIDED BY THE CLIENT
•NO UNDERGROUND UTILITIES OR IMPROVEMENTS HAVE BEEN LOCATED, EXCEPT AS NOTED.
-THERE ARE NO VISIBLE ENCROACHMENTS OTHER THAN THOSE SHOWN.
WILSON DE LA 1 ORRE
PROFESSIONAL LAND SURVEYOR
AND MAPPER No. 1870
STATE OF FLORIDA
U.E. - uTL. EASEMENT
11 • MONUMENT LNE
P.C. • PONT OF cuRvATURE
►.H. - FIRE HYDRANT
CASIO. • EASLNENT
S.D.H. - SET ORLL HOLE
CALC.(C) • CALCULATED
F.S. • FOUND SPRCL
RAO. • RADIAL
P.O.B. - PgHT of BEGINNING NOT VALID UNLESS SEALED WITH AN EMBOSSED SURVEYOR SEAL
P.O.0 • POINT OF CURVATURE
DATE: t*pa. j . l6 Ic)S S
....:r .Y... . f .IC:—: K« •..d aL•!! ...1 j• ,...d -' ../...dr d
.REAR .YARD
TRIANGLE OF VISIBILITY:
All driveway /roadway entrances and exits shall
be constructed so that vehicles may enter and
exit without posing danger to occupants, pedestrians,
or other vehicles. Structures and landscaping shall
not obscure vision above 2.5' within the triangle
commencing at the point of intersection.of the driveway
and sidewalk/right -of -way for a distance of 10' along
the driveway and 10' along the right -of way.
All walls and fences
in the front yard require
approval by the Planning
and Zoning Board.
• 3.5'
May 2000
RESIDENTIAL FENCE/ WALL
TANDA►RDS- INTERIOR LOT
REAR AND SIDE YARD :
5' HEIGIIT LIMIT
3.5
•
Swale
Sidewalk
FRONT AND SIDE YARD :
3.5' HEIGHT LIMIT
r
Strocl
PROPERTY LINES
1
MIAMI SHORES VILLAGE
FENCE WALL AND HEDGE REQUIREMENTS
Maximum height of fences walls and hedges, in any required front yard, 3 -1/2 feet except on
Biscayne Boulevard where fences and walls are 5 feet and hedges are 7 feet Maximum height
of hedges in any required side yard rear yard is 7 feet and maximum height of fences or wall
in any required side rear yard is 5 feet.
FRONT YARD FENCES
All walls or fences in any front yard shall be constructed either or ornamental masonry or of
ornamental metal, but not including any wire fence . All front fences must be approved by
Planning and Zoning Board prior to issuance of a permit.
SIDE OR REAR YARD FENCES
Walls or fences in any side or rear yard, shall be constructed of chain link, wood, ornamental
iron or aluminum, precast concrete, concrete block stucco, or ornamental masonry. The use
of all other materials or attachments such as slats, fabric, reed screening, etc., is prohibited.
Any fence, wall or hedge established adjacent to a rear plot line along an alley shall provide
a clear space of at least forty (40) square feet in area long the alley line available for the placing
of waste materials for removal.
WOOD FENCE
Permit application accompanied by two copies of survey and two copies of drawing indicating
ways to install wooden fence. Location of fence should be highlighted on survey. Owner -
builder permit may be issued.
CHAIN LINK FENCE
Permit application along with two copies of survey indicating location of fence.
Owner - builder permit may be issued.
MASONRY FENCE
Permit application must be accompanied by two copies of drawings signed and sealed by a
registered Engineer.
ORNAMENTAL IRON
Permit application must be accompanied by two sets of drawings depicting style of fence.
5' -0" MAX
2' -0"
a
B
4
- II =II e a
1 =III=
- II III °
I - III I -_- I I - I I -
- I I I - I I I - I I I - I I - III - I
1II I1I II1 - 1II II
4" X 4" Wood post
2" X 4" Wood Pall
1 "X6 "orl "X8"
Wood pickets
Concrete
WOOD FENCES
3' -0"
2915 Fences
Wood Posts
4' -0" High or Less = 6' -0" O.C.
5' -0" High or Less = 5' -0" O.C.
2915.1 Wood fences, so located on a property
that by zoning regulations they cannot be used
as a wall of a building, shall be constructed to
meet the following minimum specifications.
(a) Fences not exceeding 5 feet in
height shall be constructed to meet
the following minimum
requirements: from nominal 4 inch
by 4 inch by 8 feet -0 inch long
posts spaced 5 feet -0 inches on
centers, having a fiber stress of
1200 p.s.i. in bending, and shall be
embedded 2 feet -0 inches into a
concrete footing 1 foot -0 inches in
diameter and 3 feet -0 inches deep.
Other components shall be
designed to comply with the
provisions of this Chapter and
Chapter 23.
(b) Fences not exceeding 5 feet and 4
feet in height respectively shall be
constructed as provided in
paragraph 2915.1 (a) herein,
except that the spacing of posts
may be increased to 5 feet -0
inches and 6 feet -0 inches on
centers for these heights.