Loading...
237 NE 100 St (13)METRO PAGE' M1=TfOPOLITAN DADE COUNTY, rL �,i &► o s i METfO -DACE FLAGLER BUILDING ���4 BUILDING CODE COMPLIANCE DEPAf1TMENT Q c3 Fit) Q) 4F6 June 15, 1993 Revised ,S'eptentbe 28, 1993 CO _► C UITE 1 ME1 f4a -DADS FLAGI.Ef1 S BUILDIN 3 140 WEST FLAGLEFl SIFIEET MIAMI, FLdntDA 33130.1583 (305) 376.2901 FAX (305) 375-2908 Metro Roo/'Tile, Inc. hasJiled with this office the required and acceptable test data to support renewal and revision of arch ,Spanish "S" concrete roof file }or l,otlr Nail - On and Mortar -Set .systems. 'The rile shall be installed on ct solid mailable roof deck of 5/8" !hick plywood fin. oil new construction or to 1/2" plywood deck on re- roofing. I.CJi.114i_O.(.1_eLbisi d.� ..Mi.'�_i L niiPi17.6 paa The ncrilable deck shall be covered with a minimum 43 it basesheet ajrplied ►t'ith 1" roofing nails iiwu tin cap twelve (12) inches o.'c. along lop and within 2" of edge and end lap. .(.lead lap of base sheet shall be 3" to 6" and end laps shall be 6 ", all sealed with plastic cement. Lave drip .shall be attached over 43 basesheet with 1" roofing nails 4" o.e. and sealed over with membrane and asphalt plaster cement. Eciclz field tile and rake tile providing a 2 1/2" head lap shall be attached to the prepat eel deck, with two, 2 1/2" long by 0.130" diameter annular ring shank (twenty . rings per inch) corrosion resistant nails. A nominal 1/2" diameter weephole shall be incorporated at the bottom of each mortar closure below each cave course tile. This nail -on system may be installed up to 35 Jee1 above grade. r r f MaILIALGI The prepared deck shall consist of an underlayment (anchor sheet) corJbrming to No. 30 Type 11 (AST M 11 - 226) and tin clipped 6" o.c, on all laps, 12" o.c. in the field and 4" rm drip edge over this, ca trot - mopped 90 ii AVM D - 249 granular sr cap street by 7 amko, or equal is applied. f '' 17 :e tile shall be applied with a 2" head lap to the roof with inor consisting oJ'Rinker Roof Tile Cement mixed with sand conlbrnri„ g to ASTM C -144 far a 3:1 mix. The tiles shall be wet and set using approximately one full trowel of mortar. / Aiello Ne, Intc. mber 28, 1993 (ID: co L': tamlproldots4nerrol I'AGE2 Metro Roof Tile 305 558 2608 Due to Iju ricxuwe Andrew, this office has been inundated ivitlz requests for both new products and renewals of those to expire which has caused a large back log in responding with an official Notice 0 /Acceptance. In the interim period, please accefit this letter in allowing these products to be installed by a licensed roofing contractor in accordance with the manufacturer's f tither specifications and Chapter 34 of the South Florida Building Code until an official Notice of Acceptance is issued Sincerely )Wurs, It (ail Diamond,, Product Control Division Supervisor P.02 41 IAN DAYIE FR {DA 2. Any revision or change in the product: or process termination, unless prior change, 305 558 2608 NO'i' t (' ACCEPTANCEC ! STANDARD CONDITION Extenal.on of Acceptance may be considered after a u..: application has been filed and the supporting data, test repol: no older than ten, (10) years, have been re-- evaluated. All reports of re -.teating`ahall bear the seal, signature ;1. date of an engineer registered in the State of Florida. the materials, use, or manufacture shall automatically be cause t: approval in granted for revieiong . 3. Any unsatisfactory performance of this product or process or Change in Code provisions shall be grounds, for re''.evaluation, 4. This acceptance shall not be used as an endorgentent of cs.; product for sales or advertising purposes. 5. The Notice of Acceptance number preceded by the words Dtyd County, Florida, and followed by the expiration date may !� displayed in advertising literature. If any porUion • of Notice of Acceptance is displayed, then it shall be done in S' entirety. 6. Product approval drawings, where required for permi appltcations, shall be provided to the applicant by t : ! .. manufacturer or his distributors; unless otherwise noted in Notice of Acceptance. The prints need not be re - sealed by engineer. 7. Failure to comply with Standard conditions shall be cause.:[ termination of Approval. ' ,... ' P.06 Al 14 .f► M ETRO -DADS CUNT Er; BUILDING & ZONING DEPAmMEN t BUIIE tarn 11t N.W. 1st etnerei MIAMI, FLORIDA 33I28.18id (305) 3752612 . T . . . . Gil Diamond, Product Control Supervisor: Metropolitan Dade County Building & , Zoning Department Metro Roof Tile A1Wald r e iP^a = ' Ti ..' ID. , ,@ ACCEPTANCE t SPEiII V E C ?UDI 305 558 2608 P.05 'ACCEPTANCE No. t 09-00144Q 0 APPROVED t .Sept.. 11, 19119. EXPIRES t ept. ii, 1y9. HIIota E RIDGE AND GABLE, °rtLL 144PS AND RIDGE TILE 7 This renewal euperoedea''Produat Approval #06.0630.2 dated Septe »: 0, 1986. D Almon • , P.S. Product Control Supervisor Metropolitan Dade County -2a- Building & Zoning Department; Metro Roof Tile 40 !tls. 1 .45 305 558 2608 P.04 accirsocs $$9 .1 AMMO ... ,, . SUMS S 11!'NIITf�Q Ali �/�C PT4N _R 1 � PT(r q Q VI Y IR 1. This approves a Portland cent type $ tile. 2. Installation shall be in accordance with Section 3403 of the 1iouitt Florida Building Code, this Product Approval aotiCs or the manufacturer's recommendations, ; whichever is most re•ttictive . 3. A A ir_ Cnnt nl The manufacturer shall retain the servLCss of ea independent testing laboratory to maintain quality control. Tsat shall be performed on a minimum of five (5) tiles each h nlorida) days dss e strength according to Section 3403 of S0 ht Code and for moisture absorption according to ASTK C -4. Test samples shall be selected by a laboratory according to ASTK D-3665-82. Results shall be sent to Dade County Product Control Section every ninety (90) days. Teat reports shall bear • description of the tile by material and color, i.e. cement, grey. 4. Masklasa All tiles, both foreign and domestic, shall bear the imprint "W Tile' to permit identification in the field. 5. Applications for roofing permit shall be aCcQ, 4sean s by tW4 duplicate copies of the followings a) Notice of Acceptance 489- 0814.6 b) Manufacturer's specifications am4 stanch d dated• c) Shop drawings, approved the project architect or engineer de t a its. a. plan m o b : the L a ui red a f propose instal d n. e y� 9 Roof tiles and aceasrories shall conform to the following drawine Gee pace 2s D asw •, Pet. Product Control Supervisor Metropolitan Dade County Building i toning Department P.03 METnO.DADE CEN rEf _Metr .Roof_ T i l e ._ APPROVED: _S�1;L4�u?� 1L• 1gn� 305 558 2608 . "" 111 N.W 1,1 9mm MIAMI, flAf11UA �3128•t8la ICEQ 1 la CQnn QL No'i'ic Of ACCEPTANC Metro hook lle, Inc. . . 11350 NOV. South River Drive. Medley, FL. 331704 ' . • Your application �lication foe: Product Approval of _.11emi i1 ' y.p.�5__Eus v v r ll: under. Sections 203 and 704 of the South Florida Building C. y the use of Alternate Materials and 'types of Co unt y 1t ctio, and nd submitted in the plans, specifications With J 8011. ,a.SJAi ua Ui_$11@ 4 .2Y- AV.141-G R b�o.dl t: 1: o a !t.' 119 -4 .� 9 -4_,-._ . ai.l iglita._ 1 -6A1 has been accepted used in the Unincorporated areas ofDadehCounty u Standard Speisifi` Conditions set forth on pages 2-2a:and ACCEPTANCE No.: E1%-tlS3 iA__ • 1 1) anion , P.E. Product Control SUpeJ visul APPROVED t1��'� Metropolitan Dade County EXPIRES &Lllb l' 1 1. 19.9 - B & Zoning Ueparl.1110 .. klasa 110T t,4 i ,_.'i ILELCOMIS1iF � t —s itI7AanOlibil- ,'Aata.1 11_,M(.1,tk'J:0.11d.Ix- C l l r CallUISIQUa has beef • accepted by the This application fur ProductApp U a � Appeals . to be used in in Mel:>< :upolit a Dade Unincorporated icoi orated County unsex the incorpo� :atecl and l ► p conditions set forth above. iWag M. ack, P.B. Deputy SecretaIy Metropolitan Dade County Bowl of Rules and Appeal MIAMI SHORES VILLAGE, FLORIDA 'BUILDING ❑ Date k' 44/ 19‘ ELECTRICAL ❑ PLUMBING ❑ PERMIT N° 8861 Contractor's {{,�/ &Fe ❑ License No &Is f Work to be performed under this Permit Owner of I" ! I �= t„� % �� itr► T s Building /'J Architect .G� / Contractor or Builder 4./ Legal Lat Description 11 B1 Address of 3 %1 ✓'U Signed CONTRACTOR or BUILDER Subdi- vision Sq Ft Value of Amount of ,,� �� • Project $ � Permit $ 5 This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants qr emplpyees. r.7e (INSPECTOR) BY In consideration of the issuance to rye of this permill agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BY AUTHORITY Disapproved ____ _ ( Signed) Date_ MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date June 20,. , 67 Owner's Name and Address... .1.4.. Weld Q11.__ _ __ .__________.__. __. No.. 23Z_......_.... Street N.E..--- .1l01 et Regftered Architect and /or Engineer... _ _': a Name and address of licensed contractor_.__ ._. . Truly NQl_en__.Inc. Location and legal description of lot to be built on: Lot__ Block Subdivision Street and Number where work is to be done State work to be done and purpose of building (by floors) Fumigation and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation . Roof Covering. . _._ .._.. Estimated Total cost of improvements $ 4252 __ Amount of Permit $ Zone cubage required Plan Cubage__ _. Distance to next nearest building_...___ . _ Size of Building Lot Maximum live load to be borne by each floor.__ I hereby submit all the plans and specifications foi said building. All notices with reference to the building and its construction may be sent to___._ The undersigned applicant for this building permit doe hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen s Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared __ - - - to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Q Permit No Z. 6 / Date__ / ?' Read, Sworn to and Subscribed before me. Notary Public, State of Florida Buil g Inspector My Commission Expires._ PLANNING BOARD__ __ . DATE Chairman _ . Member Member Member Member ____ __ _ . Member . _._.._ Council Approved _____ . _ Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. APPLICATION VIKANE X FOR PERMIT TO FUMIGATE WITH CYANIDE METHYL BROMIDE ACRITET APPLICATION NO. DATE 19 1. Location of building to be fumigated 237 N.E. 100 Street Miamt Shnrpg 2. Name and address of owner of premises 1., L. Who /Ann 3. Type, size and construction of building CBS — Main. BAsidence 4. Is entire building to be fumigateu: Ye S. If not, state what portion 6. Approximate number of cubic feet of space in building or in portion to be fumigated. 22, 000 7. Kind and quantity of fumigant to be used and manner of application and length of fumigation period Vi ksge. - Approx 20 hours 8. Distance of nearest building acid direction from building to be fumigated • over 10 feet 9. In what manner will vents to exterior of building be sealed? Nylon tent 10. Date whem fumigation will be begun June 20, 1967 ' Time 4000 11. It is hereby agreed to station a guard on the premises to be fumigated during the fumigation period and to post suitable placards at each entrance into the building bearing the following words in letters at least two inches by one inch in size: "DANGER" — THIS BUILDING UNDER FUMIGATION WITH A DEADLY GAS." 12. It is hereby agreed to make such provisions that all openings into the building may be opened from the outside after the period of fumigation is over and to take such other precautions as may be necessary to insure that all of the fumigant is removed from the building before anyone is permitted to enter. 13. It is hereby agreed to notify the County Health Department when the building has been prepared for fumigation. FIRM NAME: TRULY NOLEN, INC. 600 N. W. 7th Avenue Miami 36, Florida BY (Signature of certified pest control operator in charge of this fumigation job.)