Loading...
1400 NE 101 St (11)a PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 0 7 r1 ) Job Address / it a7 a ST S� Tax Folio Legal Description Historically Designated: Yes No Owner/LessPe / Tenant C - f YL a /94.42..)t_ L/ Master Permit # `/ Z ' 0 ( Owner's Address 1 v D Y , 0) ST S r Phone ? " (¢ b / 7 . c/ &C) L) Contracting Co. 0 W /J 67Z--- Address Qualifier SS# Phone State # Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFIN PAVING FENCE SIGN WORK DESCRIPTION f2../91.,C) 11� J `1 +' t41-14,1 C ��y� Square Ft. 1 5 O WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulatin tion and zoning. Furthermore . I • e the above -named contractor to do the work stated. Signature of e FEES: PERMIT j : o President RADON D Notary as to Owner and/or Condo President Date My Commission Expires: 7 Estimated Cost (value) S 0 Signature of Contractor or Owner- Builder Date Notary as to Contractor or Owner - Builder Date My Commission Expires: C.C.F. NOTARY Electrical APPROVED: Zoning Building Mechanical Plumbing Engineering Legal Description Square Ft. 31 ** * FEES: PERMIT I , APPROVED: PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date ))/204 Job Address NE xe• {.— of o' - o,_• I H • Owner / Lessee / Tenant M19'' rYT 'x' V.% k aster ignature of owner afl /or Condo President Date: 4P d_ y —rj `I Mechanical �►' frLt , S * * C.C.F. Fire Zoning Building Plumbing Tax Folio t1'3205--- Z3 -6 3� Lp Permit # Phone 1 S(a 3 Owner's Address / 4 c'o Ate /n/ Contracting Co. OWAJP-1 Qualifier SS# - - Phone State # Municipal # Competency # Ins.Co. 4 70g c Address Architect /Engineer 04 AI C 61_1 4cf -F ' p,0,1g5, F'c 33 Bonding Company Address Mortgagor c5 . v (14491 1 /1404T4 4 Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING PENCE SIGN WORK DESCRIPTION J46 etc)-110 K.of iL Address g73b Pine) 6 L 1fD, Pf - A !C'C Estimated Cost(value)11151453 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating const uction and zoning. Furthermore, I authorize the bove -named contractor to do the work stated. ignature of •n ractor Date: . _ 2V -44, Notary as to Contrac r Owner- Builder Notary as to Owner and /or Condo President My Commission Expires: My Commission Expires OFFICIAL NOTARY SEAL MIRKA ROQUE NOTARY PUBLIC STATE OF FLORIDA * * * * * COI41LSSION %1O. CC36¢4 r � { ,t, MY COMMISSION E (P. MAY 31998 ►'( ( RADON '3 / ik'tV NOTARY TOTAL DUE or Owner- Builder ��/ Other r ` 1 1''� Electrical Engineering Q ; 1:674 JOHN C. ALTHOFF, P.E. 9830 PINES BOULEVARD PEMBROKE PINES, FL 33024 305 - 433 -231 Design of a roof deck for an exterior patio area FIGURE #1 Co�lc.. rm." AvorING at the residence of ESTER Z. PARKER and MARK D. CARPENTER 1400 N.E. 101st STREET MIAMI FLORIDA 33138 nab Coca 01 Af 4-r John C. Althoff, P.E. eg. 4085 DECO 8 JOHN C. ALTHOFF, P.E.,9830 PINES BOULEVARD, PEMBROKE PINES, FL 33024 DESIGN OF A ROOF DECK FOR AN EXTERIOR PATIO AREA AT THE RESIDENCE OF ESTER Z. PARKER AND MARK D. CARPENTER, 1400 N.E. 101ST ST., MIAMI, FL Check design loads on the steel columns and the footings Use a total dead and live load of 50 psf for a flat roof with wood rafters. The reaction on the supporting beam is: Check Beam Stresses: FIGURE 11 12.5' 15.5' • Nb kti GAC ,�I 3.0' T 50 PSF ex S LL R = (50 *15.5 = 480.5 plf. The reaction at the interior column is 480.5 *12.5 = 6,006 lbs. The axial stress on the column is P /A. For a 4 "x 4 "x 1/4" tube, A = 3.59 id. = 6006/3.59 = 1,673 psi - minimal. For properties of 4 "x12" beam, the surfaced size for design is 3.5"x11.25" with area , A = 39.38 in , section modulus = S = 73.83 in and moment of inertia = I= 415.28 in . Assume No.1 dense Southern Pine, F,= 1400 psi, F = 85 psi, and E= 1,600,000 psi, then from SFBC 2308.3b , a 10% reduction for live load is permissible, so the total dead load and live load is (0.9 *30) +20 = 47 psf. The reaction on the supporting beam is R = (47 *15.5 = 451.67 plf. Using a length between columns at 12.33' -0.5' for the shoes gives a 11.83' span , with shear V =w1/2= 451.67 *11.83/2 = 2,671.63 lbs and moment M= w1 /8= 451.67* 11.83 2 /8= 7,901.34 ft -lbs. Check bending stress Fb = M/S = 7901.34* 12/73.83 = 1284.25 psi < 1400 psi .. OK. Check shear stress Sv = V/A = 2671.63/39.38 = 67.84 psi < 85 psi .. OK. Check deflection = 5w1 = (5 *451.67* 11.83 * 1728)/ ( 384 *1600000 *415.28) = 0.29 in .. OK. Page 1 • JOHN C. ALTHOFF, P.E.,9830 PINES BOULEVARD, PEMBROKE PINES, FL 33024 DESIGN OF A ROOF DECK FOR AN EXTERIOR PATIO AREA AT THE RESIDENCE OF ESTER Z. PARKER AND MARK D. CARPENTER, 1400 N.E. 101ST ST., MIAMI, FL Soil pressure from the DL and LL with a 2'x 2' footing is 6006/4 = 1500 psf. Allow some overturning from wind acting sideways on the structure. Use q = 0.00256I(IV) from ASCE 7 -93. For K , the exposure coefficient, consider that the house is located in a suburban wooded area - but adjacent to Biscayne Bay. Exposure C will provide coefficients adequate for this design. Then K = 0.80. I = 1.05 for a residence on the hurricane shoreline. V for South Florida is 110 mph. Velocity pressure is 0.00256 *0.80 *(1.05 *110) = .27.32 psf. Gh, the gust factor, is 1.32 and Cp, the pressure coefficient is 0.8 on the windward side. Then the wind pressure on the side of the exposed rafter is p = q *Gh *Cp = 27.32 *0.80 *1.32 = 28.85 psf - use 30 psf. At the rafter exposure - use depth 8" and 0.67 *60 = 20 plf. The sideways reaction at the post line is R = (20 *15.5 = 192 lbs. For one post, P = 192/2 = 96 lbs. The reaction is at the top of the post about 8.5' above the ground level. Applied moment is 96 *8.5 = 816 ft -lbs. For the 2' footing, T = C = 816/1.33 = 614 lbs. Soil pressure at the edge of the footing from moment is P/2 = 307 psf. Total soil pressure is p = 1500 + 307 = 1,807 psf. Allow a bearing pressure of 2,000 psf for unclassified material. Determine Uplift : Consider the total dead load of the decking system. A B Weight Total Roof Decking 15.5 27 7.9 3306 Roof Joists 15.5 13 4.66 939 4245 lbs Timber Beam 25 1 10.12 253 lbs Steel Post 9 1 12.21 110 lbs 2' x 2' Footing 2 2 150 600 lbs Load on the deck area is 4245/(15.5 *27) = 10.14 psf. Reaction along the beam is R = (10.14 *15.5 = 97.45 plf. The weight on one colunm is 12.5 *(97.45 + 10.12) = 1,345 lbs. Add the colunm and the footing concrete for DL = 1345 + 110 + 600 = 2,055 lbs. Page 2 JOHN C. ALTHOFF, P.E.,9830 PINES BOULEVARD, PEMBROKE PINES, FL 33024 DESIGN OF A ROOF DECK FOR AN EXTERIOR PATIO AREA AT THE RESIDENCE OF ESTER Z. PARKER AND MARK D. CARPENTER, 1400 N.E. 101ST ST., MIAMI, FL Determine the uplift from the wind: q = 27.32 psf and Gz = 1.32. F = q *Gz *Cf. Take Cf from Table 11, ASCE 7 -93, for monoslope roofs over unenclosed structures. L/B = 15.5/25 = 0.62 - use Cf = 0.53. Then F = 27.32 *1.32 *0.53 = 19.1 psf. Uplift transferred to the roof beam is 97.45 *19.1/10.14 = 184 plf. On one column - U = 12.5 *184 = 2300 lbs. The concrete footing must be increased and placed lower in the ground. For a 2' -3" x 2' -3" x 1' -6" deep footing with 1' -0" of overburden- Timber Beam 25 1 10.12 2531bs Steel Post 9 1 12.21 110 lbs 2.25' x 2.25' Footing 5.06 1.5 150 11391bs Soil Overburden 5.06 1 120 6071bs From Roof 1345 lbs Total 34541bs A 150% factor of safety must be provided so 1.5 *2300 = 3450 lbs < 3454 lbs .. OK. Check anchor bolts: Use 5/8" bolts - for A307B bolts, from the AISC ASD Manual, allow 6.1 kips. For two bolts 2 *6.1 = 12.2 kips > 3.45... OK. Use 3/4" bolts for corrosion protection. Determine thickness of the connection angle. Pull is 3.45/2 = 1.725 kips an each angle. Take an estimated moment arm of 2" from the bolt to the vertical leg with a point of inflection at midpoint. Then M = 1 * 1725 = 1,750 in -lbs. For a 3/8" angle, S = 4 *0.375 = 0.094 in a = M/S = 1750/0.094 = 18,670 psi - less than 0.66 *Fy = 24,000 psi used as allowable for bending stresses. Check rebar in the concrete footing. 0.02 *Ag = 0.002 *18 *27 = 0.972. Four #5's produces 4 *0.31 = 1.24 in > 0.972 ... OK. Page 3 BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Lot 1! M. Description Address of Building MIAMI SHORES VILLAGE, FLORIDA a PERMIT N? 15808 EJ Work to be performed under this Permit Subdi- vision Value of Project $ DATE 195 Contractor's License No. • Amt. of Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed • BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR OR BUILDER BY AUTHORITY