Loading...
1997 Roof permitPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date G 1=24-97 Job Address 187 N. E. 100 Street Tax Folio Legal Description Historically Designated: Yes No Master Permit # '/n 9' 6 7 Owner's Address 187 N . E. 100 Street Phone ContractingCo.Quality Roofing Contractor, Inc,. Address 251 N.W. 99th Street Owner/Lessee / Tenant 1 .A1 f • ( , ! I/ S Qualifier Carlos Arocho State# RC 0 0 5 8 6 2 7 Municipal # Competency # 178 8 9 Ins. Co. Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off roof to wood deck, tin cap 301b. ASTM felt as per building code, mop on with type III asphalt one layer of 901b. ASTM felt, install valley and eave drip meal where required and install choice of tiles a•'. � e set. c� Square Ft. 2 8 s q. 2_ S b Estimated Cost (value) $ 9, 000 . 0 0 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR LMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. �( -214 7 . � e 2/4/92 stgnatr owner and/or Condo President Date Signature of Contractor or Owner- Builder Date Notary as to 0 ' er and/or My Commission Expires: APPROVED: Zoning Mechanical Building YLOU ' � t' ' RANDEZ _ MY COMMISSION N CC 324212 EXPIRES: October 10, 1997 Bonded Thru Notary Public Underwriters ..o..w. FEES: PERMIT 7 RADON C.C.F. Plumbing Phone 751-0382 Address Address Notary as to C • i actor or My Conunission Expires: NOTARY Electrical OU HERNANDEZ Da MY COMMISSION N CC 324212 EXPIRES: October 10, 1997 tf,gr �,V Bonded Thru Notary Public Underwriters elv AR BOND TOTAL DUE a 97 Engineering NUI IU Ut WMMtNC:LMLN I A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION Interest in property: Owner PERMIT NO. • TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: 2. Description of improvement: Install new tile roof . Name and address of fee simple titleholder: N/A 4. Contractor's name and address: Quality Roofing Contractor, INc. 251 N.W. 99th Street Miami, Florida 331 . CO? N1� OF 0 t 5. Surery:(Payment bond required by owner from contrEit�riy►) t, o °f da of N A 1 HE sv CERtIFY t•' ,, ORV e` Name and address: / Amount of bond $ 00 6. Lender's name and address:N A 7. Persons within the State of Florida designated by Owner upon whom notices or oth by Section 713.13(1)(a)7., Florida Statutes, - Name and address: N/A Signatut net Print Owners Name it \ e.v . 11 \ S Sworn to and subscribed before me this G day of F...rXr . . 199/ . Notary Public . � A i.. .. q .,°. -A.A 1..,- *. Print Notary's Name p.• „ • �f t It My Commission Expires: '. 97RO64297 1997 FEB 12 12:32 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 187 N.E. 1 00 Street Miami Shores, Florida 33138 3. Owner(s) name and address: l Pu F - • L - l C 1 / 187 N.E. 100 Street Miami Shores, Florida 11118 o d ° ° ISeol. a my A tN E CRKi of ice Cou ^ I Y.Cot ' cuments may be served as provided 8. In addition to himself, Owner designates the following person(s) to receive a copy of the l.ienor's Notice as provided in Section 713.13(1)(bl, Florida Statutes. Name and addiass: N/A 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Prepared by: Ca r 1 na Quality Roofing Address: 251 N.W_ Miami, Florida Arocho contractor, I 99th St ;eet 331 sn 123.0t.52 26* Contractor's Name: Appenaix UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF CATEGORY L (Low Slope Application) ❑ (Nail -On Tile) (Mortar- Adhesive Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) --// ROOF TYPE ❑ New Roof 2 ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft Sloped Roof Area (ft ,S , Total (ft 29 SG . Master Permit No. Exposure category (per ASCE 7 -88): c Building Classification category (per AS E 7 -88 table 1): Ft. A Y Ft. A Deck type: ()OOC I Xto V,J 'ATTACHMENT 10' �, Fastener Type:. 1 q (; n SIvAt1I� na , S ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) SPACING c tc Field: 0 :1).c . Perimeter: 1 1 O.C. Corner: D.C. DETAIL 1 & 2 Job Address: 1 g7 Ion 54r c E4- Page -1 ROOF PLAN T MEAN HEIGHT /2 Deck type: A /Underlayntent. Insulation: a11 D E T A I L 3 UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 12 ROOPSLOPE SLOPED SYSTEM DESCRIPTION Ridge Ventilation? ) lY� .272 „(eJA• 54 /04 -n : Ltd— Fastener type & spacing: Cap Sheet: TILE CALCULATIONS (PmaxI:92,3 r X. (Aerodynamic Muhiplier): ,(-1 ) ) - M :5 = M )7 O& PCA: (ptr.5 (Pmax2:12.1. () S X (aerodynamic ) - M = M PCA: 14 (PmaY3: 121.0 ( Aerodynamic NIuhiplier): 3 ] S 1 ) - �' 3S = M 3 .2.1(0 PCA: tat -C Page -2 ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals A a, ke ;r' Altusa Tile Alfareria del Turbio, S.A. Barquisirneto, Venezuela The expense of such testing will be incurred by the Manufacturer. PRODUCT NO. : • ACCEPTANCE NO.: 94- 0914.01 EXPIRES: APPROVED: PRODUCT CONTROL NOTICE OF ACCEPTANCE FEB 1 4 1 997 FEB 7 9 1995 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130.1563 (305) 375.2901 FAX (305) 375.2908 Your application for Product Approval of Altusa Tile Nail -On. Mortar or Adhesive Set Clay "Altusa S" Roofing Tiles under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by Redland Technologies, The Center for Applied Engineering, Inc., and Testwell Craig Laboratories & Consultants, Inc. has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specific and standard conditions set forth herein. The approval shall be valid for a period of three years. 'the Building Code Compliance Department reserves the right to secure a product or material at any time for a jobsite or manufacturer plant for quality control testing. If product or material fail to perform in the approved manner, the Code Compliance Department may revoke, modify or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require testing of this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. Raul Rodriguez Product Control Division Supervisor - PLEASE NOTE - THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. . r • c Charles Danger, P.E., Director Building Code Compliance Department Metropolitan Dade County Applicant: Altusa Tile Alfareria del Turbio, S.A. Barquisimeto, Venezuela PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Prepared Roofing Sub- Category: Tile T p.: Nail- on/Mortar Set/Adhesive Set Sub -Type: Clay System Description Contact: Carlos J. Fernandez General Manager Altusa Tile, Almar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 (305) 471 -5830 1 Raul Rodriguez Product Control No.: 94- 0914.01 Approval Date: FEB 2 2 19 5 rJ Expiration Date: FEB 1 4 1997 Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval relates to Altusa's "Altusa S" tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also available. Altusa roof tiles have been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" section in this approval for the "Altusa S" profile drawing. The "Altusa S" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Almar (USA), Inc., located in Miami, Florida, is the sole approved importer under contract for selling and distributing Altusa products in the South Florida jurisdiction. Trim Pieces TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT I = varies w = varies varying thickness ASTM C 1167 Raul Rodriguez Product Control No.: 94- 0914.01 Test Product Product Dimensions Specifications Description Altusa'S' Clay Roof I = 181/4" ASTM C 1167 High profile, interlocking, one - piece, Tile w = 10" 'S' shaped, clay roof tile equipped with '/:" thick two nail holes and a single roll. For direct deck nail -on applications only. Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Product #30 Felt #43 Coated Base Sheet Mineral Surface Cap Sheet Dimensions N/A N/A N/A Lenzingtex -ZB 140 59" x 164' roll Underlayment 22 Ibs /roll Rainproof I1 Ice and Water Shield Mopping Asphalt Flashing Cement TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll N/A N/A Test Specifications ASTM D 226 type 11 ASTM D 2626 ASTM D 249 PA 104 PA 104 PA 103 ASTM D 312 type 11! or IV ASTM D 4586 3 1 Raul Rodriguez Product Control No.: 94 0914.01 Product Description. Saturated organic felt to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. Single ply, nail - on underlayment. Single ply, nail -on underlayment with 2" self - adhering top edge. Self - adhering underlayment for use as a top ply in a two ply underlayment system with approved #30 or #43 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. Manufacturer generic generic generic Lenzing Performance, Inc. PCA #94- 0527.05 Protect -O -Wrap, Inc. PCA #94- 0714.01 W.R. Grace Co. PCA 492 -1 1 16.01 generic generic Product Asphalt Primer Roofing Nails Tin Caps Wood Battens Tile Nails Tile Screws Roof Tile Mortar ( "TileTiternl") Roof Tile Adhesive ( "Polypro® AH 160 ") Dimensions N/A min. 12 ga. with 3 / head min. 32 ga. min. 1 o.d. max. 2" o.d. vertical min. 1 "x4" horizontal min. 1" x 4" for use with vertical battens or min. 1" x 2" for use alone min. 8d x 2'V2" or ruin. iOd x 3" min. #8 x 2'V2' or min. #10 x 2" N/A N/A Test Specifications ASTM D 41 PA 114 Appendix E PA 114 Appendix E Wood Preservers Institute LP - 2 PA 114 Appendix E PA 114 Appendix E PA 123 See PCA 4 Raul Rodriguez Product Control No.: 94 Product Description Cut back, asphalt based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped, electro or mechanically galv. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment Salt pressure treated or decay resistant lumber battens Corrosion resistant, screw, smooth or annular ring shank nails. Corrosion resistant, coated, coarse thread wood screws. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Manufacturer generic generic generic generic generic generic Bermuda Roof Company, Inc. PCA #94- 0614.01 Polyfoam Products, Inc. PCA #94- 0401.01 Product Hurricane Clip & Fasteners Valley Flashing Drip Edge Dimensions Clips min. V2" width min. 0.060" thick Clip Fasteners min. 8d x 1'h" min. 26 ga. min. 16" width min. 26 ga. min. 2" face flange min. 2" deck flange Test Specifications PA 114 Appendix E ASTM A 525 PA 111 i Raul Rodriguez Product Control No.: 94- 0914.01 Product Description Manufacturer Corrosion resistant generic bronze, aluminum, stainless steel, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. A hurricane clip is required on all eave tiles. Galvanized steel valley flashing Galvanized steel drip edee generic generic Test Agency Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Testwell Craig Laboratories & Consultants. Inc. TEST REPORTS Test Identifier 7161 -03 Appendix III 7161 -03 Appendix III 25- 7200 -1 94 -084 94 -083 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0647 -01 PO402 Project No. 307025 Test #MDC -78 Lab #AAP -2 Tech: A. Porcello 6 Product Control No.: 94- 0914,01 Test Name/Report Static Uplift Testing PA 102 Static Uplift Testing PA 102(A) Static Uplift Testing PA 102 (Quik -Drive Screws, Battens) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Sct) Withdrawal Resistance Testing of screw vs. sr: c sth shank nails Wind Driven Rain PA 100 Physical Propertie ASTM C 1 167 ae Dec. 1991 Dec. 1991 Feb. 1995 May 1994 April 1994 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 Oct. 1994 Oct. 1994 SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 / 32 " or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope range. Underlayment: Roofing Tile: Product Control No.: 94- 0914.01 Install choice of approved underlayment system, noted on Page 1 of Dade County Protocol PA 120, in compliance with Section 3.02 of PA 120. See System Limitation #7. Install tile in compliance with PA 120 using one of the approved mortars or adhesives noted in this approval. Mortar or adhesive shall be applied in compliance with the mortar or adhesive manufacturer's Roofing Component Product Control Approval. The mortar or adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with PA 115 or PA 127. The mortar and adhesive attachment data is noted in Table 4, attached. Comments: 1. For re -roof applications, 1 ' / „” plywood is an acceptable substrate. 2. For mortar set applications, the first three courses of tile shall be nailed with not Tess than one nail per tile. As an alternate, the first three courses of tile shall be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than ) / 8 " which is mechanically attached to the deck with not less than one roofing nail every 1 ft'. For roof pitches from 6 ":12" to 7 ":12 ", every third tile of every fifth course, beginning at the eighth course, shall be nailed with not less than one nail per tile. 10 Raul Rodrit2ucz 1 The standard minimum roof pitch for "Altusa S ", nail -on, mortar or adhesive set tile applications is 2" rise in 12" run (2 ":12 "). The maximum roof pitch for mortar or adhesive set tile applications is 7" rise in 12" run (7 ":12 "). All nail -on tile applications having a roof pitch less than 4 ":12" shall be installed over both vertical and horizontal battens ( "Counter- Battens "), as noted in System A. All nail -on tile applications having a roof pitch in excess of 7 ":12" shall be installed over horizontal battens as noted in System C. SYSTEM LIMITATIONS 3. For nail -on applications, brass or stainless steel screws for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. 4. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. Nail -on tile shall be attached using one of the methods of attachment noted in Table 3 of this Approval. Mortar or adhesive set tile shall be attached using an approved mortar or adhesive noted in this Approval, the data of which is noted in Table 4 of this Approval. The method of attachment utilized shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 127. 5. For nail -on tile applications, an eave clip is required on all eave tile. For mortar set applications, the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the first three courses of tile shall be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3 / which is mechanically attached to the deck with not less than one roofing nail every 1 ft'. For roof pitches from 6 ":12" to 7 ":12 ", every third tile of every fifth course, beginning at the eighth course, shall be nailed with not less than one nail per tile. 6. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency. in compliance with Dade County Protocol PA 106, shall be required not less than 30 days after application to confirm tile adhesion. The results of this testing shall be reported to the Building Official and the. installer stating that the application has passed or failed PA 106 testing. If the application fails PA 106 testing, the report shall state which portion of the test was failed; Category 1 (examination for loose tile) or Category 2 (uplift testing of tile). Subsequent to testing, the installer may repair not more than 5% of field area tiles and 10% of perimeter area (i.e. ridge /rake) tile with approved tile adhesive. The installer shall place an identifiable marking on each repaired tile for future reference. Any PA 106 re -test shall not include any marked tile. For mortar or adhesive set tile applications, 30/90 hot mopped underlavment applications may be installed perpendicular to the roof pitch prior to June 1, 1995 unless stated otherwise by the material manufacturer. Thereafter, 30/90 underlayment systems shall be installed parallel to the roof pitch in compliance with Appendix 'A' of Dade County Protocol PA 120. Raul Rodriguez Product Control No.: 94- 0914.01 SYSTEM LIMITATIONS (CONTINUED) 8. All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 9. The Altusa "Altusa S" tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with Dade County Protocol PA 115 or PA 127 shall be done as a'Moment Based System' 10. Applications for roofing permits shall include a completed Section II of the Uniform Building Permit, a copy of Altusa Tile's current specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 11. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. 12. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 12 Ra ul Rutlri_ticz Product Control No.: 94- 0914,01 DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 94-09 Ol Table 1: Aerodynamic Multiplier - X (ft') from PA 108 Testing Tile Profile Altusa 'S' Tile X (ft') Batten Application 0.29 X (ft') Direct Deck Application 0.31 crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed in two manufactured holes located 1' / and 1 from the head of the tile. 13 Raul Rodrieuez 'K?) a e G. Restor Moments aue to Gravity - M (ft-Ibf) frorn PA 102 Testing Table 3: Attachment Resistance Expressed as a Moment - M, (ft-Ibf) from PA 102 and PA 102(A) Testing Tile Profile TILE APPLICATION APPROVED NAILS APPROVED SCREWS APPROVED FIELD CLIP WITH: APPROVED EAVES CLIP WITH: 1 nail 2 nails 1 screw 2 screws 1 nail 2 nails 1 nail 2 nails Altusa 'S' Tile Battens N/A N/A N/A 26.80' N/A N/A N/A N/A Direct Deck 6.20 8.40 28.70 31.80 21.20 25.30 26.90 34.90 DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 94-09 Ol Table 1: Aerodynamic Multiplier - X (ft') from PA 108 Testing Tile Profile Altusa 'S' Tile X (ft') Batten Application 0.29 X (ft') Direct Deck Application 0.31 crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed in two manufactured holes located 1' / and 1 from the head of the tile. 13 Raul Rodrieuez 'K?) a e G. Restor Moments aue to Gravity - M (ft-Ibf) frorn PA 102 Testing Tile Profile Table 4: Attachment Resistance Expressed as a Moment - M (ft-Ibf) from PA 101 Testing Tess Tile Profile Tile Application Attachment Resistance Altusa 'S' Tile Battens Mortar Set .;f 24.50. Adhesive Set 66.50 DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 94-09 Ol Table 1: Aerodynamic Multiplier - X (ft') from PA 108 Testing Tile Profile Altusa 'S' Tile X (ft') Batten Application 0.29 X (ft') Direct Deck Application 0.31 crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed in two manufactured holes located 1' / and 1 from the head of the tile. 13 Raul Rodrieuez 'K?) a e G. Restor Moments aue to Gravity - M (ft-Ibf) frorn PA 102 Testing Tile Profile 3 ":12" or Tess 4":12" 5 ":12•• 6":12'• 7'•:12" or greater Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Altusa 'S' Tile 4.47 5.35 4.40 5.27 4.31 5.16 4.20 5.03 4.08 N/A DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 94-09 Ol Table 1: Aerodynamic Multiplier - X (ft') from PA 108 Testing Tile Profile Altusa 'S' Tile X (ft') Batten Application 0.29 X (ft') Direct Deck Application 0.31 crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed in two manufactured holes located 1' / and 1 from the head of the tile. 13 Raul Rodrieuez 'K?) X11; I'(►5A . Clay flout Tiles DOVE TAIL LOCKS . PROFILE DRAWING ALTUSA 'S' TILE 14 Rau Rodriaucz 10" Product Control No.: 94- 0914,01 18" 7.— METRODADE EMI l:tI .. 91 TI METROPOLITAN DADE'COUNTY FLORIDA METRO•DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DE T 003 METR FLAGLER BUILDING ER STREE 140 WEST STREET MIAMI, FLORIDA ,3130. FAX (305) 375.2908 pplication has been filed and the supporting aluated. Extensions of Acceptance may be considered a be r data, test reports no older than ten (10) years, All reports of re- testing shall bear the seal, signature and date of an eng Florida. Any revision or change in the materials, use, or ma nefd turere of the p or process s shall automatically be cause for termination, unless prior app roval is grant 2. A n unsatisfactory performance of this product or process or a change in Code provisions shall be grounds J. Y for re- evaluation. 4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5. y , Florida, and followed by the ' ature: If any portion of the Notice of Acceptance is The Notice of Acceptance number preceded by the words Dade Count expiration date may be displayed in advertising It displayed, then it shall be done in its entirety. Iicant by 6. Product app�'oval drawings, where required for applicati in t Notice of be provided to Accep t T11e pPints need the manufacturer or his dist unless otherwise not be re-sealed by an engineer. Failure�to comply with the Standard Conditions shall be cause for termination of the Approval. This approval supersedes all previous approvals. Last Approval Number 94- 0106.18 Raul Rodriguez Product Control Division Supervisor ineer re istered in the State of Legal Description Owner's Address /$ 7 A/.E toa SG /'/eEs' Contracting Co. /4A).. Address Qualifier SS# - - Phone State # Municipal # Competency # Ins.Co. Architect /Engineer /tlithE" Address Address Mortgagor a.20W) Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN Bonding Company /00t WORK DESCRIPTION , i'9 /� % d•J Square Ft. WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I auth9.r• a the above -named contractor to do the work stated. Signature of owner and /or Condo President Signature of Contractor or Owner- Builder Date: �1n.Pl2iLt s 4$v Notary as to Owner at Notary as to Contractor or Owner- Builder My Commission Expire 4: P06 OFFICIAL NOTARY SEAL My Commission Expires: BARBARA ANN FUGAZZI I `' 01 * COMMISSION NUMBER c CC360191 ** * * * B " O Of MY OOMMISSIdIN EXP. * * * * * * * ** OF F\ MAR. 291998 ' NOTARY % TOTAL DUE ✓"'., FEES: PERMIT 3i APPROVED: PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Job Address /? 7 ../E 4 02 2 67 Tax Folio / Lessee / Tenant (SA) 12/9 RADON C.C.F. Zoning Building Mechanical Plumbing 24(9A' Estimated Cost(value) g. (0.7C7 Date: Fire i 1 Master Permit # 3 Phone 77 Other kC ' Electrical Engineering dV1 Du Quesne & Associates, Inc. Consulting Engineers Testing Laborator ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE -IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 Owner's Name: -' �, 2' - L-W 5 1-W- N Fermit # 40 Job Address r 0 tJ (loo CaT .. . M ( f ��l=! ; �'�- Roofing Contractor t t- t N p..00 ;~1 N! Type of Tile' Ai - t u'' 9 S { 't'.n�c►� -1 -SGT.. Date Installed: 4 ' Z " ?7� Approximate Roof Height - feet Roof Pitch* 3 r l - Type of Access to Roof Scaffolds 1t Ladder Other Approximate Square Footage of : Roof `s oOO ft 2 Required Testing Force: 35 Ibs Testing ' <Equipment: Date Tested' 4 30 9 1 1 SITE SPECIFIC INFORMATION ................ ................. ............... ................. ................ ................. ................. TEST RESULTS P •PASS, F =FAIL Environmental • Civil • Structural Buildin Inspection Services Chatillion DFIS:.100 UTR N2 12332 Uplift Pull Test (P or F) > 2 Test Location 3 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Uplift Pull T ! P or F) Test Location 27 28 29 - 30 31 37 38 39 40 41_:.,-..• • 42 43 44 45 46 47 48 49 50 Test Location 52 53 54 55 56 57 58 59 60 61 62 63 65 66 70> < 71 72 73 74 75 Uplift Pull Test (P or F) SKETCH OF ROOF IN BACK IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS REPS' TTE► \ + ► \ Jo Quesne, P.E. - Civneer P.E. # 513 Du Quesne & Associates, Inc. E.B. License' #0005245 Lab Certification #94- 0318.01 Please Note: This form is not valid unless Company logo appears in color (burgundy) 7821 S.W. 24th Street • Suite 104 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 $KETCH OF ROOF JOB SHEET NO CALCULATED BY CHECKED BY SCALE 18'1 kJ E: i r ciT" . • y • " 1" . I + OF DATE -Ti DATE 1 1 1 1 ; j) 4' 145 1 r NOTES* BUILDING INSPECTION DEPARTMENT. APPLICATION FOR BUILDING PERMIT Application is hereby uuade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Ov.-ner's Name and Address peared therein by him stated ar / true. Permit No Disapproved � D (Signed) Building Ins tor MIAMI SHORES VILLAGE .4- At Date — S ( -72 .... No.. / ( .. Street._ `_`�' tL .,:,. .. ...., . .. ,:, - - Registered Architect and/or Engineer .. .,, ..Stet , LL Name and address of licensed contractor �m t el Location and legal description of lot to be built on: Lot Block Subdivision Number lJ_ l4 . If _ Street and Number where work is to be done 1�7 _ _ - •• -• — State work to be done and' purpose of building (by floors) /2,:.4.- ��� Z- � � �� 64 n ra L /6 _ _...._.._...._.._.._.._ and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundgiv t' Roof Covering f 2•` �C� Estimated Total cost of improvements $ l � "— Amount of Permit t Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of Libor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed un this pennit, as are licensed by Miami Shores Village. Remarks..._ (Signed) STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- Read, Sworn to and Subscribed before me. to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts Notary Public, State of Florida My Commission Expires LANNINC BOARD _.._ DATE Chairman Member \fcrobcr Member Member _._____...__._..__.__...._ Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection oe faulty materials and /or workmanship.