1997 Roof permitPERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date G 1=24-97 Job Address 187 N. E. 100 Street Tax Folio
Legal Description Historically Designated: Yes No
Master Permit # '/n 9' 6 7
Owner's Address 187 N . E. 100 Street Phone
ContractingCo.Quality Roofing Contractor, Inc,. Address 251 N.W. 99th Street
Owner/Lessee / Tenant 1 .A1 f • ( , ! I/ S
Qualifier Carlos Arocho
State# RC 0 0 5 8 6 2 7 Municipal # Competency # 178 8 9 Ins. Co.
Architect/Engineer
Bonding Company
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTION Tear off roof to wood deck, tin cap 301b. ASTM felt as per building
code, mop on with type III asphalt one layer of 901b. ASTM felt, install
valley and eave drip meal where required and install choice of tiles
a•'. � e set. c�
Square Ft. 2 8 s q. 2_ S b Estimated Cost (value) $ 9, 000 . 0 0
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR LMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
�(
-214 7 . � e 2/4/92
stgnatr owner and/or Condo President Date Signature of Contractor or Owner- Builder Date
Notary as to 0 ' er and/or
My Commission Expires:
APPROVED:
Zoning
Mechanical
Building
YLOU ' � t' ' RANDEZ
_ MY COMMISSION N CC 324212
EXPIRES: October 10, 1997
Bonded Thru Notary Public Underwriters
..o..w.
FEES: PERMIT 7 RADON C.C.F.
Plumbing
Phone 751-0382
Address
Address
Notary as to C • i actor or
My Conunission Expires:
NOTARY
Electrical
OU HERNANDEZ Da
MY COMMISSION N CC 324212
EXPIRES: October 10, 1997
tf,gr �,V Bonded Thru Notary Public Underwriters
elv AR
BOND
TOTAL DUE
a
97
Engineering
NUI IU Ut WMMtNC:LMLN I
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
Interest in property: Owner
PERMIT NO. • TAX FOLIO NO.
STATE OF FLORIDA:
COUNTY OF DADE:
2. Description of improvement: Install new tile roof .
Name and address of fee simple titleholder: N/A
4. Contractor's name and address: Quality Roofing Contractor, INc.
251 N.W. 99th Street Miami, Florida 331
. CO? N1� OF 0 t
5. Surery:(Payment bond required by owner from contrEit�riy►) t, o °f da of
N A 1 HE sv CERtIFY t•' ,,
ORV e`
Name and address: /
Amount of bond $ 00
6. Lender's name and address:N
A
7. Persons within the State of Florida designated by Owner upon whom notices or oth
by Section 713.13(1)(a)7., Florida Statutes,
- Name and address: N/A
Signatut net
Print Owners Name it \ e.v . 11 \ S
Sworn to and subscribed before me this G day of F...rXr . . 199/ .
Notary Public . � A i.. .. q .,°. -A.A 1..,- *.
Print Notary's Name p.• „ • �f
t
It
My Commission Expires: '.
97RO64297 1997 FEB 12 12:32
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with
Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address: 187 N.E. 1 00 Street
Miami Shores, Florida 33138
3. Owner(s) name and address: l Pu F - • L - l C 1 /
187 N.E. 100 Street Miami Shores, Florida 11118
o d ° ° ISeol.
a my A tN E CRKi of ice Cou ^ I Y.Cot '
cuments may be served as provided
8. In addition to himself, Owner designates the following person(s) to receive a copy of the l.ienor's Notice as provided in
Section 713.13(1)(bl, Florida Statutes.
Name and addiass: N/A
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Prepared by: Ca r 1 na
Quality Roofing
Address: 251 N.W_
Miami, Florida
Arocho
contractor, I
99th St ;eet
331 sn
123.0t.52 26*
Contractor's Name:
Appenaix
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
ROOF CATEGORY
L (Low Slope Application) ❑ (Nail -On Tile)
(Mortar- Adhesive Set Tile)
❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other)
--// ROOF TYPE
❑ New Roof 2 ❑ Recovering ❑ Repair ❑ Maintenance
Flat Roof Area (ft Sloped Roof Area (ft ,S , Total (ft 29 SG . Master Permit No.
Exposure category (per ASCE 7 -88): c Building Classification category (per AS E 7 -88 table 1):
Ft.
A
Y
Ft.
A
Deck type: ()OOC I Xto V,J
'ATTACHMENT
10'
�,
Fastener Type:. 1 q (; n SIvAt1I� na , S
ROOF HEIGHT AND SYSTEM DETAILS
(Draw details as needed)
SPACING
c tc
Field: 0 :1).c . Perimeter: 1 1 O.C. Corner: D.C.
DETAIL 1 & 2
Job Address: 1 g7 Ion 54r c E4-
Page -1
ROOF PLAN
T
MEAN HEIGHT /2
Deck type:
A /Underlayntent.
Insulation:
a11
D E T A I L 3
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
12
ROOPSLOPE
SLOPED SYSTEM DESCRIPTION
Ridge Ventilation?
) lY�
.272
„(eJA• 54 /04 -n : Ltd—
Fastener type & spacing:
Cap Sheet:
TILE CALCULATIONS
(PmaxI:92,3 r X. (Aerodynamic Muhiplier): ,(-1 ) ) - M :5 = M )7 O& PCA: (ptr.5
(Pmax2:12.1. () S X (aerodynamic ) - M = M PCA: 14
(PmaY3:
121.0 ( Aerodynamic NIuhiplier): 3 ] S 1 ) - �' 3S = M 3 .2.1(0 PCA: tat -C
Page -2
ATTACHMENTS REQUIRED
1) Fire Directory Listing Page
2) Dade County Product Control
Notice of Acceptance -Cover Sheet
a) Specific System Description
b) Specific System Limitation
c) General Limitations
d) Applicable Detail Drawings
3) Municipal Permit Application
4) Other Component Approvals
A a, ke ;r'
Altusa Tile
Alfareria del Turbio, S.A.
Barquisirneto, Venezuela
The expense of such testing will be incurred by the Manufacturer.
PRODUCT NO. :
•
ACCEPTANCE NO.: 94- 0914.01
EXPIRES:
APPROVED:
PRODUCT CONTROL NOTICE OF ACCEPTANCE
FEB 1 4 1 997
FEB 7 9 1995
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE DEPARTMENT
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130.1563
(305) 375.2901
FAX (305) 375.2908
Your application for Product Approval of Altusa Tile Nail -On. Mortar or Adhesive Set Clay "Altusa S" Roofing
Tiles under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of
Construction, and completely described in the plans, specifications and calculations as submitted by Redland
Technologies, The Center for Applied Engineering, Inc., and Testwell Craig Laboratories & Consultants, Inc.
has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County,
Florida under the specific and standard conditions set forth herein.
The approval shall be valid for a period of three years. 'the Building Code Compliance Department reserves the
right to secure a product or material at any time for a jobsite or manufacturer plant for quality control testing. If
product or material fail to perform in the approved manner, the Code Compliance Department may revoke, modify
or suspend the use of such product or material immediately. The Building Code Compliance Department reserves
the right to require testing of this product or material should any amendments to the South Florida Building Code be
enacted affecting this product or material.
Raul Rodriguez
Product Control Division
Supervisor
- PLEASE NOTE -
THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS.
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under
the conditions set forth above.
. r
•
c
Charles Danger, P.E., Director
Building Code Compliance Department
Metropolitan Dade County
Applicant:
Altusa Tile
Alfareria del Turbio, S.A.
Barquisimeto, Venezuela
PRODUCT CONTROL NOTICE OF ACCEPTANCE
ROOFING SYSTEM APPROVAL
Category: Prepared Roofing
Sub- Category: Tile
T p.: Nail- on/Mortar Set/Adhesive Set
Sub -Type: Clay
System Description
Contact:
Carlos J. Fernandez
General Manager
Altusa Tile, Almar (USA), Inc.
6645 Northwest 77th Avenue
Miami, FL 33166
(305) 471 -5830
1
Raul Rodriguez
Product Control No.: 94- 0914.01
Approval Date: FEB 2 2 19 5 rJ
Expiration Date: FEB 1 4 1997
Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof
tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan
clays. This Product Control Approval relates to Altusa's "Altusa S" tile profile. Refer to appropriate
Product Control Approvals for other tile profiles.
The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim
pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all
profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also
available.
Altusa roof tiles have been tested in compliance with the South Florida Building Code
requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for
the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" section in this approval for the
"Altusa S" profile drawing. The "Altusa S" profile has been tested for both wind characteristics and
static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based
System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval.
Almar (USA), Inc., located in Miami, Florida, is the sole approved importer under contract for
selling and distributing Altusa products in the South Florida jurisdiction.
Trim Pieces
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT
I = varies
w = varies
varying thickness
ASTM C 1167
Raul Rodriguez
Product Control No.: 94- 0914.01
Test Product
Product Dimensions Specifications Description
Altusa'S' Clay Roof I = 181/4" ASTM C 1167 High profile, interlocking, one - piece,
Tile w = 10" 'S' shaped, clay roof tile equipped with
'/:" thick two nail holes and a single roll. For
direct deck nail -on applications only.
Accessory trim, clay roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each
tile profile.
Product
#30 Felt
#43 Coated Base
Sheet
Mineral Surface Cap
Sheet
Dimensions
N/A
N/A
N/A
Lenzingtex -ZB 140 59" x 164' roll
Underlayment 22 Ibs /roll
Rainproof I1
Ice and Water Shield
Mopping Asphalt
Flashing Cement
TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS
30" x 75' roll
36" x 75' roll
or
60" x 75' roll
36" x 75' roll
N/A
N/A
Test
Specifications
ASTM D 226
type 11
ASTM D 2626
ASTM D 249
PA 104
PA 104
PA 103
ASTM D 312
type 11! or IV
ASTM D 4586
3
1
Raul Rodriguez
Product Control No.: 94 0914.01
Product
Description.
Saturated organic felt
to be used as a nailed
anchor sheet.
Saturated and coated
organic base sheet for
single or double ply
underlayment.
Mineral surfaced
asphalt roll roofing
for use as a top ply in
a double ply
underlayment system.
Single ply, nail - on
underlayment.
Single ply, nail -on
underlayment with 2"
self - adhering top
edge.
Self - adhering
underlayment for use
as a top ply in a two
ply underlayment
system with approved
#30 or #43 as the base
layer.
Asphalt for bonding a
mineral surface cap to
a mech. attached base
sheet in a double ply
underlayment system.
Cut back, asphalt
based, asbestos free,
fiber reinforced,
trowel grade cement
for repair and flashing
applications.
Manufacturer
generic
generic
generic
Lenzing
Performance, Inc.
PCA #94- 0527.05
Protect -O -Wrap, Inc.
PCA #94- 0714.01
W.R. Grace Co.
PCA 492 -1 1 16.01
generic
generic
Product
Asphalt Primer
Roofing Nails
Tin Caps
Wood Battens
Tile Nails
Tile Screws
Roof Tile Mortar
( "TileTiternl")
Roof Tile Adhesive
( "Polypro® AH 160 ")
Dimensions
N/A
min. 12 ga. with
3 / head
min. 32 ga.
min. 1 o.d.
max. 2" o.d.
vertical
min. 1 "x4"
horizontal
min. 1" x 4" for use
with vertical battens
or
min. 1" x 2" for use
alone
min. 8d x 2'V2" or
ruin. iOd x 3"
min. #8 x 2'V2' or
min. #10 x 2"
N/A
N/A
Test
Specifications
ASTM D 41
PA 114
Appendix E
PA 114
Appendix E
Wood Preservers
Institute LP - 2
PA 114
Appendix E
PA 114
Appendix E
PA 123
See PCA
4
Raul Rodriguez
Product Control No.: 94
Product
Description
Cut back, asphalt
based coating used to
facilitate bonding of
dissimilar materials.
Annular ring shank,
hot dipped, electro or
mechanically galv.
roofing nails for use
in underlayment
attachment.
Corrosion resistant
circular disc for use in
underlayment
attachment
Salt pressure treated
or decay resistant
lumber battens
Corrosion resistant,
screw, smooth or
annular ring shank
nails.
Corrosion resistant,
coated, coarse thread
wood screws.
Prepared mortar mix
designed for mortar
set roof tile
applications.
Two component
polyurethane adhesive
designed for adhesive
set roof tile
applications.
Manufacturer
generic
generic
generic
generic
generic
generic
Bermuda Roof
Company, Inc.
PCA #94- 0614.01
Polyfoam Products,
Inc.
PCA #94- 0401.01
Product
Hurricane Clip &
Fasteners
Valley Flashing
Drip Edge
Dimensions
Clips
min. V2" width
min. 0.060" thick
Clip Fasteners
min. 8d x 1'h"
min. 26 ga.
min. 16" width
min. 26 ga.
min. 2" face flange
min. 2" deck flange
Test
Specifications
PA 114
Appendix E
ASTM A 525
PA 111
i
Raul Rodriguez
Product Control No.: 94- 0914.01
Product
Description Manufacturer
Corrosion resistant generic
bronze, aluminum,
stainless steel,
galvanized steel or
plastic attachment
clips for supplemental
tile attachment. Clips
are installed with
corrosion resistant
roofing nails
compatible with the
clip. A hurricane clip
is required on all eave
tiles.
Galvanized steel
valley flashing
Galvanized steel drip
edee
generic
generic
Test Agency
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
Testwell Craig Laboratories
& Consultants. Inc.
TEST REPORTS
Test Identifier
7161 -03
Appendix III
7161 -03
Appendix III
25- 7200 -1
94 -084
94 -083
7161 -03
Appendix II
Letter Dated Aug. 1, 1994
P0647 -01
PO402
Project No. 307025
Test #MDC -78
Lab #AAP -2
Tech: A. Porcello
6
Product Control No.: 94- 0914,01
Test Name/Report
Static Uplift Testing
PA 102
Static Uplift Testing
PA 102(A)
Static Uplift Testing
PA 102
(Quik -Drive Screws, Battens)
Static Uplift Testing
PA 101
(Mortar Set)
Static Uplift Testing
PA 101
(Adhesive Set)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Mortar Sct)
Withdrawal Resistance
Testing of screw vs. sr: c sth
shank nails
Wind Driven Rain
PA 100
Physical Propertie
ASTM C 1 167
ae
Dec. 1991
Dec. 1991
Feb. 1995
May 1994
April 1994
Dec. 1991
Aug. 1994
Aug. 1994
Sept. 1993
Oct. 1994
Oct. 1994
SYSTEMS
(CONTINUED)
Deck Type: Wood, Non - insulated
Deck Description: New construction 19 / 32 " or greater plywood or wood plank.
SYSTEM D: Mortar or Adhesive Set Application
Slope Range: 2 ":12" to 7 ":12"
Note: System D is only acceptable in this slope range.
Underlayment:
Roofing Tile:
Product Control No.: 94- 0914.01
Install choice of approved underlayment system, noted on Page 1 of Dade
County Protocol PA 120, in compliance with Section 3.02 of PA 120. See
System Limitation #7.
Install tile in compliance with PA 120 using one of the approved mortars or
adhesives noted in this approval. Mortar or adhesive shall be applied in
compliance with the mortar or adhesive manufacturer's Roofing Component
Product Control Approval. The mortar or adhesive attachment shall provide
sufficient attachment resistance expressed as a moment to meet or exceed the
required moment of resistance determined in compliance with PA 115 or PA
127. The mortar and adhesive attachment data is noted in Table 4, attached.
Comments: 1. For re -roof applications, 1 ' / „” plywood is an acceptable substrate.
2. For mortar set applications, the first three courses of tile shall be nailed with
not Tess than one nail per tile. As an alternate, the first three courses of tile
shall be applied in mortar over a single layer of minimum 12 ga. wire mesh
with square openings of not less than ) / 8 " which is mechanically attached to the
deck with not less than one roofing nail every 1 ft'. For roof pitches from
6 ":12" to 7 ":12 ", every third tile of every fifth course, beginning at the eighth
course, shall be nailed with not less than one nail per tile.
10
Raul Rodrit2ucz
1 The standard minimum roof pitch for "Altusa S ", nail -on, mortar or adhesive set tile applications
is 2" rise in 12" run (2 ":12 "). The maximum roof pitch for mortar or adhesive set tile applications
is 7" rise in 12" run (7 ":12 ").
All nail -on tile applications having a roof pitch less than 4 ":12" shall be installed over both vertical
and horizontal battens ( "Counter- Battens "), as noted in System A. All nail -on tile applications
having a roof pitch in excess of 7 ":12" shall be installed over horizontal battens as noted in System
C.
SYSTEM LIMITATIONS
3. For nail -on applications, brass or stainless steel screws for mechanical attachment of tiles shall
have a head diameter larger than that of the preformed holes in the tile.
4. System installation shall be in compliance with the system specifications outlined in this Product
Control Approval. Nail -on tile shall be attached using one of the methods of attachment noted in
Table 3 of this Approval. Mortar or adhesive set tile shall be attached using an approved mortar
or adhesive noted in this Approval, the data of which is noted in Table 4 of this Approval. The
method of attachment utilized shall provide sufficient attachment resistance expressed as a moment
to meet or exceed the required moment of resistance determined in compliance with Dade County
Protocol PA 115 or PA 127.
5. For nail -on tile applications, an eave clip is required on all eave tile. For mortar set applications,
the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the
first three courses of tile shall be applied in mortar over a single layer of minimum 12 ga. wire mesh
with square openings of not less than 3 / which is mechanically attached to the deck with not less
than one roofing nail every 1 ft'. For roof pitches from 6 ":12" to 7 ":12 ", every third tile of every
fifth course, beginning at the eighth course, shall be nailed with not less than one nail per tile.
6. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited
testing agency. in compliance with Dade County Protocol PA 106, shall be required not less than 30
days after application to confirm tile adhesion. The results of this testing shall be reported to the
Building Official and the. installer stating that the application has passed or failed PA 106 testing. If
the application fails PA 106 testing, the report shall state which portion of the test was failed;
Category 1 (examination for loose tile) or Category 2 (uplift testing of tile). Subsequent to testing,
the installer may repair not more than 5% of field area tiles and 10% of perimeter area (i.e.
ridge /rake) tile with approved tile adhesive. The installer shall place an identifiable marking on
each repaired tile for future reference. Any PA 106 re -test shall not include any marked tile.
For mortar or adhesive set tile applications, 30/90 hot mopped underlavment applications may be
installed perpendicular to the roof pitch prior to June 1, 1995 unless stated otherwise by the material
manufacturer. Thereafter, 30/90 underlayment systems shall be installed parallel to the roof pitch in
compliance with Appendix 'A' of Dade County Protocol PA 120.
Raul Rodriguez
Product Control No.: 94- 0914.01
SYSTEM LIMITATIONS
(CONTINUED)
8. All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for
identification in the field.
9. The Altusa "Altusa S" tile profile has been tested for both wind characteristics and static uplift
performance, therefore, attachment calculations for installation in compliance with Dade County
Protocol PA 115 or PA 127 shall be done as a'Moment Based System'
10. Applications for roofing permits shall include a completed Section II of the Uniform Building
Permit, a copy of Altusa Tile's current specifications and details, a copy of this Product Control
Approval and a copy of the Product Control Approval of any Roofing Component used in the
proposed tile application. Reference shall be made to appropriate data for the required fire rating.
11. The applicant shall retain the services of a Dade County certified testing laboratory to maintain
quality control in compliance with the South Florida Building Code and related protocols.
12. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South
Florida Building Code.
12
Ra ul Rutlri_ticz
Product Control No.: 94- 0914,01
DATA FOR ATTACHMENT
CALCULATIONS
14
Product Control No.: 94-09 Ol
Table 1: Aerodynamic Multiplier - X (ft')
from PA 108 Testing
Tile
Profile
Altusa 'S' Tile
X (ft')
Batten Application
0.29
X (ft')
Direct Deck Application
0.31
crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed
in two manufactured holes located 1' / and 1 from the head of the tile.
13
Raul Rodrieuez
'K?)
a e G. Restor Moments aue to Gravity - M (ft-Ibf)
frorn PA 102 Testing
Table 3: Attachment Resistance Expressed as a Moment - M, (ft-Ibf)
from PA 102 and PA 102(A) Testing
Tile
Profile
TILE
APPLICATION
APPROVED
NAILS
APPROVED
SCREWS
APPROVED
FIELD CLIP
WITH:
APPROVED
EAVES CLIP
WITH:
1 nail
2 nails
1 screw
2 screws
1 nail
2 nails
1 nail 2 nails
Altusa 'S' Tile
Battens
N/A
N/A
N/A
26.80'
N/A
N/A
N/A
N/A
Direct Deck
6.20
8.40
28.70
31.80
21.20
25.30
26.90
34.90
DATA FOR ATTACHMENT
CALCULATIONS
14
Product Control No.: 94-09 Ol
Table 1: Aerodynamic Multiplier - X (ft')
from PA 108 Testing
Tile
Profile
Altusa 'S' Tile
X (ft')
Batten Application
0.29
X (ft')
Direct Deck Application
0.31
crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed
in two manufactured holes located 1' / and 1 from the head of the tile.
13
Raul Rodrieuez
'K?)
a e G. Restor Moments aue to Gravity - M (ft-Ibf)
frorn PA 102 Testing
Tile
Profile
Table 4: Attachment Resistance Expressed as a Moment - M (ft-Ibf)
from PA 101 Testing
Tess
Tile
Profile
Tile
Application
Attachment
Resistance
Altusa 'S' Tile
Battens
Mortar Set
.;f 24.50.
Adhesive Set
66.50
DATA FOR ATTACHMENT
CALCULATIONS
14
Product Control No.: 94-09 Ol
Table 1: Aerodynamic Multiplier - X (ft')
from PA 108 Testing
Tile
Profile
Altusa 'S' Tile
X (ft')
Batten Application
0.29
X (ft')
Direct Deck Application
0.31
crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed
in two manufactured holes located 1' / and 1 from the head of the tile.
13
Raul Rodrieuez
'K?)
a e G. Restor Moments aue to Gravity - M (ft-Ibf)
frorn PA 102 Testing
Tile
Profile
3 ":12"
or
Tess
4":12"
5 ":12••
6":12'•
7'•:12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Altusa 'S' Tile
4.47
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
N/A
DATA FOR ATTACHMENT
CALCULATIONS
14
Product Control No.: 94-09 Ol
Table 1: Aerodynamic Multiplier - X (ft')
from PA 108 Testing
Tile
Profile
Altusa 'S' Tile
X (ft')
Batten Application
0.29
X (ft')
Direct Deck Application
0.31
crews for pile installation over battens shall be #8 x 2Y:" long, corrosion resistant, Quik -Drive screws installed
in two manufactured holes located 1' / and 1 from the head of the tile.
13
Raul Rodrieuez
'K?)
X11; I'(►5A
. Clay flout Tiles
DOVE TAIL LOCKS .
PROFILE DRAWING
ALTUSA 'S' TILE
14
Rau Rodriaucz
10"
Product Control No.: 94- 0914,01
18"
7.—
METRODADE
EMI
l:tI .. 91
TI
METROPOLITAN DADE'COUNTY FLORIDA
METRO•DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE DE T 003
METR FLAGLER BUILDING
ER STREE
140 WEST STREET
MIAMI, FLORIDA ,3130.
FAX (305) 375.2908
pplication has been filed and the supporting
aluated.
Extensions of Acceptance may be considered a be r
data, test reports no older than ten (10) years,
All reports of re- testing shall bear the seal, signature and date of an eng
Florida.
Any revision or change in the materials, use, or ma nefd turere of the p or process s shall automatically
be cause for termination, unless prior app roval is grant
2.
A n unsatisfactory performance of this product or process or a change in Code provisions shall be grounds
J. Y
for re- evaluation.
4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes.
5.
y , Florida, and followed by the
' ature: If any portion of the Notice of Acceptance is
The Notice of Acceptance number preceded by the words Dade Count
expiration date may be displayed in advertising It
displayed, then it shall be done in its entirety. Iicant by
6. Product app�'oval drawings, where required for applicati
in t Notice of be provided to Accep t T11e pPints need
the manufacturer or his dist unless otherwise
not be re-sealed by an engineer.
Failure�to comply with the Standard Conditions shall be cause for termination of the Approval.
This approval supersedes all previous approvals.
Last Approval Number 94- 0106.18
Raul Rodriguez
Product Control Division
Supervisor
ineer re istered in the State of
Legal Description
Owner's Address /$ 7 A/.E toa SG /'/eEs'
Contracting Co. /4A).. Address
Qualifier SS# - - Phone
State # Municipal # Competency # Ins.Co.
Architect /Engineer /tlithE" Address
Address
Mortgagor a.20W) Address
Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
Bonding Company /00t
WORK DESCRIPTION , i'9 /� % d•J
Square Ft.
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO
SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I
auth9.r• a the above -named contractor to do the work stated.
Signature of owner and /or Condo President Signature of Contractor or Owner- Builder
Date:
�1n.Pl2iLt s 4$v
Notary as to Owner at Notary as to Contractor or Owner- Builder
My Commission Expire 4: P06 OFFICIAL NOTARY SEAL My Commission Expires:
BARBARA ANN FUGAZZI
I `' 01 * COMMISSION NUMBER
c CC360191
** * * * B " O Of MY OOMMISSIdIN EXP. * * * * * * * **
OF F\ MAR. 291998 ' NOTARY % TOTAL DUE ✓"'.,
FEES: PERMIT 3i
APPROVED:
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Job Address /? 7 ../E 4 02 2 67 Tax Folio
/ Lessee / Tenant (SA) 12/9
RADON
C.C.F.
Zoning Building
Mechanical Plumbing
24(9A'
Estimated Cost(value) g. (0.7C7
Date:
Fire i 1
Master Permit #
3
Phone 77
Other
kC ' Electrical
Engineering
dV1
Du Quesne & Associates, Inc.
Consulting Engineers
Testing Laborator
ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE
-IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE
PROTOCOL PA 106
Owner's Name: -' �, 2' - L-W 5 1-W- N Fermit # 40
Job Address r 0 tJ (loo CaT .. . M ( f ��l=! ; �'�-
Roofing Contractor t t- t N p..00 ;~1 N!
Type of Tile' Ai - t u'' 9 S { 't'.n�c►� -1 -SGT.. Date Installed: 4 ' Z " ?7�
Approximate Roof Height - feet Roof Pitch* 3 r l -
Type of Access to Roof Scaffolds 1t Ladder Other
Approximate Square Footage of : Roof `s oOO ft 2
Required Testing Force: 35 Ibs Testing ' <Equipment:
Date Tested' 4 30 9 1 1
SITE SPECIFIC INFORMATION
................
.................
...............
.................
................
.................
.................
TEST RESULTS
P •PASS, F =FAIL
Environmental • Civil • Structural
Buildin Inspection Services
Chatillion DFIS:.100
UTR N2 12332
Uplift Pull
Test (P or F) >
2
Test Location
3
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Uplift Pull
T ! P or F)
Test Location
27
28
29 -
30
31
37
38
39
40
41_:.,-..• •
42
43
44
45
46
47
48
49
50
Test Location
52
53
54
55
56
57
58
59
60
61
62
63
65
66
70> <
71
72
73
74
75
Uplift Pull
Test (P or F)
SKETCH OF ROOF IN BACK
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT
QUALITY CONTROL TEST.
THIS REPS' TTE►
\ + ► \
Jo Quesne, P.E. -
Civneer
P.E. # 513
Du Quesne & Associates, Inc.
E.B. License' #0005245
Lab Certification #94- 0318.01
Please Note: This form is not valid unless
Company logo appears in
color (burgundy)
7821 S.W. 24th Street • Suite 104 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426
$KETCH OF ROOF
JOB
SHEET NO
CALCULATED BY
CHECKED BY
SCALE
18'1 kJ E: i r ciT" . • y • " 1" .
I + OF
DATE -Ti
DATE
1
1
1
1
;
j)
4'
145
1
r
NOTES*
BUILDING INSPECTION DEPARTMENT.
APPLICATION FOR BUILDING PERMIT
Application is hereby uuade for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Ov.-ner's Name and Address
peared
therein by him stated ar / true.
Permit No
Disapproved � D
(Signed)
Building Ins tor
MIAMI SHORES VILLAGE
.4- At
Date — S ( -72
.... No.. / ( .. Street._ `_`�' tL
.,:,. .. ...., . .. ,:, - -
Registered Architect and/or Engineer .. .,, ..Stet , LL
Name and address of licensed contractor
�m t el
Location and legal description of lot to be built on:
Lot Block Subdivision
Number lJ_ l4 . If _
Street and Number where work is to be done 1�7 _ _ - •• -• —
State work to be done and' purpose of building (by floors) /2,:.4.- ��� Z- � � ��
64 n ra L /6 _ _...._.._...._.._.._.._
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories
To be constructed of Kind of foundgiv t' Roof Covering
f 2•` �C�
Estimated Total cost of improvements $ l � "— Amount of Permit t
Zone cubage required .Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of Libor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed un this
pennit, as are licensed by Miami Shores Village.
Remarks..._ (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. j ss
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
Read, Sworn to and Subscribed before me.
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
Notary Public, State of Florida
My Commission Expires
LANNINC BOARD _.._ DATE
Chairman Member
\fcrobcr Member
Member _._____...__._..__.__...._ Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection oe faulty
materials and /or workmanship.