Loading...
BP2002-773Date Type Insp'n Permit No. Name Company Phone # For Inspector: Approved 6 Correction Re-Insp'n Fee MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Time 4al Addres ! 1 / D D L 5B'Vt e Q PROPERTY OWNER Name St 04 ! "1 ik.e. i Address i 3 NE r ) 0 0 U-1 NI , omit i / f` 3, l 3 Home Telephone 3 J 35 v; 3y // . 1 0 Business Telephone 3 05_759 _. g C Fax 3 0 S_ 7 6-7--- X23 6 TYPE OF MANAGEMENT (✓ ) New Construction Enclosure Alteration Exterior Repair Alteration Interior Demolish Relocation of Structure Shell Only Foundation Only Add'I Attachment Other Add'I Detachment Other INSTRUCTIONS - The following steps must be taken to obtain a permit from the Miami Shores Village: Step 1. Complete the attached permit application which must be signed by the property owner and qualifier. Both signatures must be notarized. Please print or type to allow for a more accurate processing of your application. If roofing work will be done, a roofing application must be submitted along with this permit application. Step 2. Submit the completed application with all necessary documents to the Building, Planning and Zoning Department for processing. During the processing of your application, you may be asked to submit additional information. APPLICATION PERMIT TYPE (✓ ) Building Electrical Mechanical Plumbing LPGX Roofing Fence Other Address Apt. Folio Number Description of Work (Ail h-a-OWS H Lot Block Subdivision PB PG Zoning Linear Feet Current Use of Property Square Feet Units Floors Proposed Use of Property Value of Work 2--0-0 U Bldg Value Tenant Information Chg. Contractor Renewal Revision Extension Supplement Reinspection PERMIT CHANGE (✓ ) ARCHITECT Name License No. Address Telephone Fax PERMIT APPLICATION Master Permit No. Subsidiary Permit No./ � 3 City State Flood Zone Base Floor Elev. Zi Tax Assessed/Appraised Value ENGINEER Name License No. Address Telephone Fax CONTRACTOR Name License No. Address Telephone Fax Qualifier Name Page 2 IMPORTANT NOTICES 1. DO NOT BEGIN ANY WORK WITHOUT HAVING RECEIVED YOUR VALIDATED PERMIT AND PERMIT CARD. Applying for a permit does not grant the right to begin construction. HOURS OF CONSTRUCTION are limited to: Monday through Friday from 7:30 a.m. to 6:00 p.m., and Saturday from 8:00 a.m. to 5:00 p.m. No inspections will be conducted on weekends or holidays. 2. All construction of demolition areas MUST BE MAINTAINED IN A CLEAN, NEAT AND SANITARY CONDITION free from construction debris. 3. STREETS AND NEIGHBORING PROPERTIES SHALL BE KEPT FREE FROM DIRT AND DEBRIS. 4. SWALES MUST BE PROTECTED FROM BEING DAMAGED BY EQUIPMENT OR VEHICLES, AND MAY NOT BE USED FOR STORAGE. A bond is required for work in or near the street/sidewalk. 5. CONSTRUCTION TRAILERS ARE PROHIBITED ON SINGLE FAMILY RESIDENTIAL CONSTRUCTION SITES. Other construction may have a trailer which requires a separate permit. 6. PORTABLE TOILETS for a construction site require a separate permit. 7. DO NOT DISCHARGE WATER INTO THE RIGHT OF WAY OR STORM DRAINS without approval from the Building, Planning and Zoning Department. 8. EQUIPMENT AND MATERIALS SHALL BE STORED at least 10 feet from the edge of pavement. 9. . Department of Health and Rehabilitative Services (HRS) approval is required for applications involving septic tanks. Department of Environmental Resources Management (DERM) and/or Miami -Dade Water and Sewer Department (MDWASD) approval is required for applications involving sewers. AFFIDAVIT - Please read carefully. Application is hereby made to obtain a permit to do work and installation as indicated. I, the OWNER of the property, certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, POOL, EXTERIOR DOOR, MECHANICAL, WINDOW, FENCE, DRIVEWAY, ROOFING and SIGNS and there may be additional permits required from other governmental agencies. I, the OWNER of the property, have disclosed all information related to any work at the property performed in the prior twelve months to the Building Official. Further, I am fully aware that if the cumulative cost of work to my home or business under this and any other permit equals or exceeds fifty percent (50 %) of the fair market value of the structure, the entire structure must meet the present federal flood criteria for finished floor elevation. I am also fully aware that if the total cost of work to my home or business under this and any other permit exceeds fifty percent (50 %) of the replacement cost of the structure, then the entire. structure must conform to the current code requirements of the Building Code. WARNING TO OWNER: Your failure to record a NOTICE OF COMMENCEMENT may result in you paying twice for improvements to your property. If you are spending more than $2,500 or intend to obtain financing, you may wish to consult with your attorney or lender before recording your Notice of Commencement. The Notice of Commencement must be recorded at: 22 N.W. 1st Street, 1°' Floor, (305) 679 -1078. Once recorded, the Notice of Commencement must be POSTED AT THE JOB SITE in accordance with Section 713 -35 of Florida Statutes. Review the brochure at Village Hall on Construction Lien Law and Choosing a Contractor. STATE OF FLO A, COUNTY OF MIAMI -DADE STATE OF FLORIDA, COUNTY OF MIAMI -DADE Signature of Owner kC Print Name / & �. n Print Name m to and subscribed before me this Signature of No bbc - u -oY b + GI BE. e �P1G0..1> �o B uer SEAL: tiP f �% cou'"� 4 6697 O +. a CC7 0 0701'19 2 Q oso. sol , A l F OFF 0 Personally known ' -= OR, Produced Identification a Type of Identification Produced roduced:t'" �� ' 1 4' y Signature of Contractor / Qualifier Sworn to and subscribed before me this day of Signature of Notary Public - State of Florida SEAL: PERMIT APPLICATION Personally known OR, Produced Identification Type of Identification Produced: Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Printed: 4/24/02 Applicant: SCOT & Owner: JOB ADDRESS: 134 ContraEtor Local Phone: Signe NE 100 Building Permit Permit Number: BP2002 -773 CHERYL SUSAN MARKEN ST Contractor's Address: Permit Status: Approved Permit Expiration: 10/14/02 Construction Value: Work: WINDOWS REPLACEMENT (15) HAVE EXISTING SHUTTERS $2,200.00 Parcel # 1132060132150 Legal Description: MIAMI SHORES SEC 1 AMD PB 10 -70 LOT 10 & E1/2 OT 11 B 16 ' IT SIZE C- If there is no permit package accessible on the job -site for inspectors to verify, there will be no inspections. Re- inspection fee is $50.00, which must be paid in advance before calling for another inspection. (INSPECTOR) BY: This Permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in 'compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit 1 assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) . BY: 11 rIn ).01, ;VIIAMI ADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Sunshine Windows Manufacturing, Inc. 1745 W. 33 rd Place Q llialeah FL 33012 C Y application for Product Approval of: Series_165.0 Aliiiil n m Hvrizo tnl SlitliWVin law- (XOXIImpa.cr x_ Nact_I»1 /�nc! under Chapter 8.of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend - the use of such product or..material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:00 0521.01 (Revises No.: 99 0326.11) Expires 08%:1 :9/2002 — ? TIIIS IS THE COVERSI-IEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved:06 /15 /2000 CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE l o r Internet mail address: postmaster ©buildingcodeonline.com MIAMI -DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 CONTRACTOR LICENSING SECTION (305)375.2527 FAX (305) 375-2558 CONTRACTOR ENFORCEMENT SECTION (305) 375-2966 FAX (305) 375-2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372-6339 Raul Rodriguez Chief Product Control Division .rancisco . Quintana. R.A. Director Miami -Dade County Building Code Compliance Office Homepage: http : / /www.buildingcodeonline.com Sunshine Windows Manufacturing NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This revises and replaces Notice of Acceptance No. 99- 0326.11, which was issued on August 19, 1999. It approves an aluminum horizontal sliding window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series 1650 Aluminum Horizontal Sliding Window (XOX) Non - Impact & Large Missile Resistant and its components shall be constructed in strict compliance with the following documents: Drawing No HS99 -03, titled "Series 1650 Aluminum Horizontal Sliding Window (XOX)" Sheets 1 through 5 of 5, dated 3/25/99, bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 3.2 For Design Pressure Rating vs. Window Size for the different non - impact window options, see "Design Pressure Chart" tables in sheets 1 and 2 of approved drawings. For Design Pressure Rating of large missile impact windows see Design Pressure Rating in shcct 4. 4. INSTALLATION 4.1 The aluminum horizontal sliding window and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): to determine whether the installation requires a hurricane protection system or not, see corresponding table in approved drawing. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South F Building Code (SFBC) in order to properly evaluate the installation of this system Manu Perez, P.E. Product Ci of Examiner Produ trot Division 2 of 3 ACCEPTANCE No.: 00- 0524.01 APPROVED JUN 1 5 2000 EXPIRES : August 19. 2002 Sunshine Windows Manufacturing ACCEPTANCE No.: 00- 0524.01 APPROVED : JUN 1 5 2000 EXPIRES August 19, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) . Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other _purpose. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and thi ldast pag 3. �,Clla� i1,it- Mariu Pere P.E. Product Produc ntrol Division END OF THIS ACCEPTANCE 3 of 3 of Examiner BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI -DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Sunshine Windows Manufacturing, Inc. 1745 W. 33 Place Hialeah, Fl 33012 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee (BCPRC) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCPRC reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County or Florida Building Code. DESCRIPTION Series— `1650 "— Horizontal=Sliding Window - - - - APPROVAL DOCUMENT: Drawing No. HS99 -02, titled "Series 1650 Aluminum Horizontal Sliding Window (XO) 3/16" and ' /." Annealed Glass ", sheet l,through 3, prepared, signed and sealed by Francisco Hernandez, P.E., dated 3/4/99, bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 99- 0202.11and, consists of this page 1 as well as approval document mentioned above. The submitted documentation was reviewed by Raul Rodriguez. NOA No 02 -0125.02 Expiration Date: tFebruary28 200 Approval Date: March 72002 Page 1 IM/NMI-0 PRODUCT CONTROL NOTICE OF ACCEPTANCE Sunshine Windows Manufacturing, Inc. 1745 W. 33 rd Place Hialeah FL 33012 Approved:06 /15/2000 CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE 1 of Internet mail address: postmaster ®buiidingcodeonline.com MIAMI -DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375.2908 CONTRACTOR LICENSING SECTION (305) 375-2527 FAX (305) 375.2558 CONTRACTOR ENFORCEMENT SECTION (305) 375-2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375.2902 FAX (305) 372.6339 Your application for Product Approval of: sSc %r_ies_16S0 A/rrruiu.n�rr Hvrizv►ttrr/ Slirlirr; IV iudow Impnc! & - tVurr /»ry�ach under Chapter 8 of the Code of Miami -Dade County governing the esu of Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or..material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:00 0524.01 (Revises No.: 99 - 0326.11) Expires:0,8 /1912002 Raul Rodriguez Chief Product Control Division TIIIS IS TIIE COVERSI SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Y 1rancisco 1 Quintana. R.A. Director Miami -Dade County Building Code Compliance Office Homepage: http : / /www.buildingcodeonline.com Sunshine Windows Manufacturing ACCEPTANCE No.: 00- 0524.01 APPROVED JUN 1 5 2000 EXPIRES : August 19, 2002 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This revises and replaces Notice of Acceptance No. 99- 0326.11, which was issued on August 19, 1999. It approves an aluminum horizontal sliding window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series 1650 Aluminum Horizontal Sliding Window (XOX) Non - Impact & Large Missile Resistant and its components shall be constructed in strict compliance with the following documents: Drawing No HS99 -03, titled "Series 1650 Aluminum Horizontal Sliding Window (XOX)" Sheets 1 through 5 of 5, dated 3/25/99, bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 3.2 For Design Pressure Rating vs. Window Size for the different non - impact window options, see "Design Pressure Chart" tables in sheets 1 and 2 of approved drawings. For Design Pressure Rating of large missile impact windows see Design Pressure Rating in sheet 4. 4. INSTALLATION 4.1 The aluminum horizontal sliding window and its components shall be installed in strict compliance with the approved drawings. 4.2 Hurricane protection system (shutters): to determine whether the installation requires a hurricane protection system or not, see corresponding table in approved drawing. 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South FF Building Code (SFBC) in order to properly evaluate the installation of his system awiLe Manu Perez, P.E. Product Ci of Examiner Produ trol Division 2 of 3 Sunshine Windows Manufacturing ACCEPTANCE No.: 00- 0524.01 APPROVED : JUN 1 5 2000 EXPIRES : August 19, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) . Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other _purpose. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and thi is last page 3. Mary Pere P.E. Product ol Examiner Produc ntrol Division END OF THIS ACCEPTANCE 3 of 3 DESIGN PRESSURE RT - PSF SERIES-1650 ALUMINUM HORIZONT WINDOW (XOX) HURRICANE PROTECTION S REQUIRED - WINDOf�A DIMENSION ANCHOR SCHED DSB �! TS 3/16" ED GLASS 3J16" ANNEALED AT VENTS i/4" ANNEALED AT FIXED , PQZ HEAD & SRI PER ARE 1 3/4" LL 1 3/4" SILL 2 1/2" SILL 6" MAX. O WIDTH HEIGHT EXT. INT. EXT. INT. EXT. INT. EXT. INT. 4 N 74' 74' 2 6 - 5 3 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 106 1/4' 7 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 t 11' 7 40.7 67.5 67.5 67.5 40.7 118.4 70.0 118.4 38 3 5 3 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 106 1/4' 7 40.7 55.7 55.7 55.7 40.7 84.1 70.0 84.1 111' 7 40.7. 53.2 53.2 53.2 40.7 80.2 70.0 80.2 74' 50 5 / 6 ' 5 4 40.7 62.6 62.6 62.6 40.7 90.9 68.7 90.9 106 1/4' 7 40.7 42.2 42.2 42.2 40.7 63.7 60.4 63.7 111' 7 40.3 40.3 40.3 40.3 40.7 60.8 59.7 60.8 74' 63' 5 5 40.7 50.3 49.2 50.3 40.7 65.1 49.2 65.1 1061/4• 7 33.9 33.9 33.9 33.9 40.5 51.2 40.5 51.2 111' 7 32.4 32.4 32.4 32.4 39.9 48.9 39.9 48.9 4 CA x 96 ' 72' 24' 5 2 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 64' 6 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 96' 6 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 108' 7 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 72' 36' 5 . 3 40.7 67.5 67.5 67.5 40.7 122.5 70.0 122.5 84' 6 40.7 67.5 67.5 67.5 40.7 115.6 70.0 115.6 96' 6 40.7 66.3 66.3 66.3 40.7 100.0 70.0 100.0 106' 7 40.7 58.4 58.4 58.4 40.7 88.1 70.0 88.1 72' 415' 5 4 40.7 67.5 67.5 67.5 40.7 100.6 70.0 100.6 64' 6 40.7 57.5 57.5 57.5 40.7 86.7 70.0 86.7 6 40.7 49.7 49.7 49.7 40.7 75.0 68.6 75.0 105' 7 40.7 43.8 43.8 43.8 40.7 66.0 66.0 66.0 72' 60 � 5 5 40.7 54.5 53.8 54.5 40.7 71.1 53.8 71.1 84' 6 40.7 46.0 46.0 46.0 40.7 64.9 49.1 64.9 96' 6 39.8 39.8 39.8 39.8 40.7 60.0 45.9 60.0 108' 7 35.0 35.0 35.0 35.0 40.7 52.8 43.9 52.8 BASED ON FTL -1006 DATED 10 -25 -94 TEST SIZE= 111" X 63" (XOX) TEST LOADS DESIGN LOADS EXTERIOR PRESSURE +59.8 PSF EXTERIOR PRESSURE +39.9 PSF INTERIOR PRESSURE -79.1 PSF INTERIOR PRESSURE -52.7 PSF WATER INFILTRATION TEST TESTED GLASS 6.1 PSF AND 10.5 PSF DSB ANNEALED AT VENTS 3/16' ANNEALED AT FIXED FALSE MUNTINS (SURFACE APPLIED) MAY BE USED 4 3/4" MAX. TYPICAL ELEVATION (XOX) NOTE: FOR NUMBER OF ANCHORS REQUIRED FOR EACH UNIT SIZE REFER TO ANCHOR SCHEDULE COLUMN IN THE DESIGN PRESSURE CHART. APPRCVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DA 4... BY _ PRODUCT CONT''L DIVISION BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE NO 00 oSZ¢ . 01 FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Placa Hialeah. Florida 33012 Pfi: (305364 -9052 Fax: 305 20 -511 o„ B JN oats: 3 -9 -99 scats: 112"=1 R.rwa"3 -75 -00 Revision; DRAWING NO. HS99 -03 SHEET 1 OF 5 WINDOW HEIGHT •..•.. I .. J L ,1 ,l - I I I. -IL 11 ' it 11 ' l 0 I. it I ii II 11 I It II II II \ II II 11 ,� 11 n .II.. `, , y'-__' JL 11 \ 11 11 • II 11 11 11 II 11 1 11 11 1 II AfP 1 .1 la II I I 1 II I n I II II 1. 6" MAX. O WINDOW WIDTH FALSE MUNTINS (SURFACE APPLIED) MAY BE USED 4 3/4" MAX. TYPICAL ELEVATION (XOX) NOTE: FOR NUMBER OF ANCHORS REQUIRED FOR EACH UNIT SIZE REFER TO ANCHOR SCHEDULE COLUMN IN THE DESIGN PRESSURE CHART. APPRCVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DA 4... BY _ PRODUCT CONT''L DIVISION BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE NO 00 oSZ¢ . 01 FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Placa Hialeah. Florida 33012 Pfi: (305364 -9052 Fax: 305 20 -511 o„ B JN oats: 3 -9 -99 scats: 112"=1 R.rwa"3 -75 -00 Revision; DRAWING NO. HS99 -03 WINDOW HEIGHT DESIGN PRESSURE CHART - PSF SERIES -1650 ALUMINUM HORIZONTAL SLIDING WINDOW (XOX) 1/4" TEMPERED GLASS AT VENTS AND FIXED WINDOW DIMENSION ANCHOR sampu ,E HURRICANE PROTECTION IS REQUIRED PER HEAD & SILL PER 4M18 13/4" SILL 21/2" SILL WIDTH HEIGHT EXT. INT. EXT. INT. 74' 26 ' 5 3 46.7 215.9 70.0 215.9 1061/4 7 46.7 197.7 70.0 197.7 CA 111' 7 46.7 188.1 70.0 188.1 74' - 3/6' 5 4 46.7 162.8 70.0 162.8 E-, CA 106 1/4• 7 46.7' 143.5 70.0 1 111• 7 46.7 136.0 70.0 136.0 74' 50 5/8' 5 5 46.7 119.6 70.0 119.6 106 1/4• 7 46.7 105.0 70.0 105.0 111' 7 46.7 103.8 70.0 103.8 74 63- 5 5 46.7 85.6 70.0 85.6 1061 7 46.7 70.5 70.0 70.5 111' 7 46.7 69.3 69.3 69.3 2 EA A x " , x, 72' 24 � 5 3 46.7 237.7 70.0 237.7 84 6 46.7 237.7 70.0 237.7 98' 7 46.7 237.7 70.0 237.7 108' 7 46.7 208.0 70.0 208.0 72' 36 5 4 46.7 176.1 70.0 176.1 84' 6 46.7 172.9 70.0 172.9 98' 7 46.7 170.7 70.0 170.7 108' 7 46.7 147.9 70.0 147.9 72 48' 5 4 46.7 132.2 70.0 132.2 84 6 46.7 124.0 70.0 124.0 96 7 46.7 119.3 70.0 119.3 108' 7 46.7 115.6 70.0 115.6 72" Kr 5 5 46.7 93.5 70.0 93.5 84" 6 46.7 85.4 70.0 85.4 95" 7 46.7 79.9 70.0 79.9 108' 7 46.7 76.3 70.0 76.3 TEST SIZE= 111" X 63' (XOX) TEST LOADS DESIGN LOADS. EXTERIOR PRESSURE +104.0 PSF EXTERIOR PRESSURE +69.3 PSF INTERIOR PRESSURE -104.0 PSF INTERIOR PRESSURE -69.3 PSF WATER INFILTRATION TEST itJ GLASS 7.0 PSF AND 10.5 PSF 1/4" TEMPERED AT VENTS 1/4' TEMPERD AT FIXED I T1 1 1I 11 II 11 11 11 II 1111 11 11 \ II II ; II JL .,:,:.. -_ _JL ii II \ II II li 11 11 11 11 II I II - O 11 II I. I II II 11 II 11 L J L J . i i ,, 11 1 I I 1 1 I „ II II II P'1 II it I I 1 1 J L -,r II ;; ,,/ 11 / , 11� I L ..14. I II I II 1 II I II I, �_ ..,,,_ ,j / I, J ,1 11 II 11 11 1 II 1 11 1 11 1 II I II I I II 11 11 II II II II - I -- 1 ■ - 3 1/4" MAX. 4 101 � i 17 WINDOW WIDTH a 'l 1/4" MAX. N 1 3 1/4" MAX. FALSE MUNTINS (SURFACE APPLIED) ' MAY BE USED 17 1/4" MAX. f 1 TYPICAL ELEVATION (XOX) APPROVED AS COMPLYING WITH THE SOUTH FLORID: BUILDING C09E DA /r1 BY PRODUCT C ROL DIVISION BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE NO °O - SZ4.0 / NOTE: FOR NUMBER OF ANCHORS REQUIRED FOR EACH UNIT SIZE REFER TO ANCHOR SCHEDULE COLUMN IN THE DESIGN PRESSURE CHART. 3 - 26 Do FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Placa Hialea Florida 33012 Ph: (305)384 -9952 Fas:(305)828 -511 p O Drawn By JN Dots: 3 -9 -99 Seals: 1 /2 " =1 Redsion:3 -25 -OP Revision: DRAWING NO. HS99 -03 SHEET 2 OF 5 WINDOW HEIGFfT z 0 0 • : 4 . . • 4 • II • • . • . ...)/ I 0 I AYLUN0 I / 4 MIN. LIVIOCUNICSNI I IN I U NIAQUINI rt (FOR NUMBER OF ANCHORS REFER TO . ANCHOR SCHEDULE IN DESIGN PRESSURE CHART) / . • • 4'4 . • 0.5 • .s. \ . 4 • • • :• • •: ATFAHMENT TIASONRY . . VERTICAL SECTION ATTACHMENT TO WOOD DETAIL 3/16* SMS 1 1/2" MIN. PENETRATION INTO W000. (FOR NUMBER OF ANCHORS REFER TO ANCHOR SCHEDULE IN DESIGN PRESSURE CHART) 4c (2) WEEP HOLES 4 • :• • r" :• VERTICAL SECTION WITH SILL RISER 3/16" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY (FOR NUMBER OF ANCHORS REFER TO ANCHOR SCHEDULE IN DESIGN PRESSURE CHART) WINDOW WIDTH • • 3/16" • SMS 1 1/2' MIN. PENETRATION:. IKTO• WOOD. (FOR NUMBER OF 'ANCHORS REFER.. • . . • ANCHOR - SCHEDULE IN •DESIGN • .PRESSURE CHART). 3/16" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY. • (FOR NUMBER OF ANCHORS REFER TO ANCHOR SCHEDULE 1N. DESIGN PRESSURE CHART) 1/4" MAX.. SHIM SPACE ATTACHMENT TO MASONRY DETAIL 3/113* TAPCONS 1 1/4' MIN: EMBEDMENT INTO MASONRY. (FOR • NUMBER OF ANCHORS REFER TO ANCHOR SCHEDULE IN DESIGN PRESSURE CHART) 3/16" SMS l's I/27' MIN. PENETRATION :INTO WOOD. (FOR :NUMBER ; OF ANCHORS REFER : TO. ANCHOR. SCHEDULE IN DESIGN: PRESSURE CHART). • -• HORIZONTAL SECTION HORIZONTAL SLIDING WINDOW SECTIONS 1 . • . .' • 1 I ATTACHMENT TO WOOD • VERTICAL SECTION GLAZING METHOD: . • USE ADHESIVE BEDDING COMPOUND AND GLAZJNG FOAM TAPE ON EXTERIOR. • EXTRUDED ALUMINUM SNAP ON GLAZING BEAD WITH VINYL BULB ON. INTERIOR. WOOD - BUCKS NOT FLY SUNSHINE:WINDOWS:44V ?SUSTAIN .. LOADS IMPOSED: BY . GLAZING SYSTEM -. 'APPROVED AS 'COMPLYING WITH SOUTH FLORIDA BUILDING - CODE • ' "- • 'DAT /4" . • BY - PRODUC CODE 10F -- .ACOEPTANCE. No: 0 -.-. • -0 • • ' . • • • • . FRANCISCO HERNANDEZ FLORIDA PE .# _51393 50Une' Vows 1745 W. 33ni Raid% flor1do 33012 Ph: (305)364-0952 FOE(305)525-51 • .-..., • JN — Droirt. ar - • DRAWING NO.- . , 8Ht'Et 3 OF 5 CO 4' HOLES 1 Inn d • . • • 4 q .1 ' ,ATTACHMENT TO MASONRY ERTICAL SECTION AT 3 5/8" FROM CORNERS MAX. AND THE REST 17 1/4" O.C. MAX. • fu U) 3/18" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY AT 3 5/8" FROM CORNERS MAX. AND THE REST 17 1/4" O.C. MAX. ATTACHMENT TO WOOD DETAIL 3/16" SMS 1 1/2" MIN. PENETRATION INTO WOOD AT " MAX. FROM CORNERS AND THE REST 14 1/4" O.C. MAX. DESIGN PRESSURE RATING + 60.0 PSF -60.0 PSF FOR ALL WINDOW SIZES EQUAL OR SMALLER THAN TEST UNIT (2) 2" WEEP HOLES WINDOW WIDTH U ATTACHMENT TO WOOD VERTICAL SECTION HORIZONTAL SECTION (XOX) INTO WOOD AT 3 5/8" FROM CORNERS MAX. AND THE REST 17 1/4." O.C. MAX. • 3 12 APPROVED AS COMPLYING WTH THE SOUTH FLORIDA BUILDING CODE DATE r OD BY Pt2ODUC�C '►TYROL DIV:S;ON BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE Ito OD - 0J-2-# - 0/ • • .1/4" MAX. SHIM SPACE 3 8/8" MAX. II IMPACTI GLASS II II FALSE MUNT1NS (SURFACE APPUED) MAY BE USED I It 17 1/4" MAX. I I IMPAC1j I CLASS _ — II II I 3/1'6" SMS 1 1/2" MIN. PENETRATION INTO WOOD AT 3 5/8" FROM CORNERS MAX. AND THE REST 17 1/4" O.C. MAX. ATTACHMENT TO MASONRY DETAIL 3/16" TAPCONS 1 1/4" MIN. EMBEDMENT INTO MASONRY AT 3 MAX. FROM CORNERS AND THE REST 14 1/4" O.C. MAX. LARGE MISSILES IMPACT WINDOW 1 3 5/8" MAX. • . TYPICAL ELEVATION ()COX) • 1 • • WINDOW WIDTH 17 1/4" MAX. BASED ON FTL -1835 DATED 8 -4 -98 TEST SIZE= 1 11 " X 63" (XOX) TEST LOADS= +90.0 —90.0 PSF DESIGN LOADS= +60.0 —60.0 PSF WATER INFILTRATION TEST= 9.0 PSF TESTED GLASS= 3/8" HEAT STRENTHENED LAMINATED CYCLIC WIND LOAD TEST= +60.0 — 60.0 PSF I HURRICANE RESISTANT SHUTTERS ARE NOT REQUIRED) GAZING : MATERIAL : 3/8" OVERALL LAMINATED GLASS USING TWO UGHTS. OF •118" HEAT STRENGTHENED GLASS WITH AN 0.010" INTERLAYER F1LM, GLASSLAM SAFETY PLUS, AND 3/8" WIDE CLOSED CELL FOAM, FRANK LOWE RUBBER AND GASKET S -10, ON EACH SIDE OF FILM AT PERIMETER EDGE. METHOD: INTERIOR GLAZED WITH 3/8" GLAZING PENETRATION USING A CLEAR COLORED ADHESIVE BEDDING COMPOUND SCHNEE MOREHEAD 5731 AND DOW CORNING 795, AND AN EXTRUDED ALUMINUM SNAP ON GLAZING BEAD. GLAZING BEAD FASTENED TO FRAME WITH TWO NO. 8 BY 3/4" PHSMS PER BEAD. • WOOD BUCKS NOT BY SUNSHINE WINDOWS MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM!1i FRANCISCO HERNANDEZ FLORIDA PE # 51393 um* PART • REQD. DESCRIPTION MATERIAL 1 SW - 019 1 FRAME HEAD 6083 -T5 2. SW -019 1 FRAME SILL 6063 -T5 3 SWxxx21 1 INSERT TRACK 6063 -T5 4 SW -018 AS ROD GLAZING BEAD 6063 -T5 5 SW -012 2/VENT SUDER TOP /BOTTOM RAIL 6063 -T5 6 SW3019 AS RQD FIN SEAL PILE FELT 7 SW1520 AS RQD GLAZING TAPE FOAM 8 SW321W 2/VENT WHEEL BRASS 9 SW -017 1/VENT MOVING MEETING RAIL 6063 -T5 10 SW40111 2 FIXED MEETING RAIL 6063 -T5 11 SW -AS AS RQD ASSEMBLY SCREWS # 8X1' PH PHIWP CRS 12 SW -013 2 JAMB 6063 -T5 . 13. • SW*- 016 1/VENT . MOVING: S,IPE RAIL 6063 -T5 14 SW3257 AS ROD WEATHER STRIP BULB VINYL 15 SW -667 AS RQD LATCH ZINC 16 SW -S10 2 /SILL RETICULATED FILTER FOAM 17 SW40771 1 SILL RISER 6063 -T5 18 - AS RQD SIUCONE DC- 795/SM -5731 L 1-- 0.394 2.123 - 1 0 'il 0.812 h h-- 1.625 1.675 MOVING _11. -1 1812 MEETING SW -017 6063 -T5 1-- RAIL 1.7 1.250 �- 0.395 �--� 0.750 �- GLAZING STOP SW-1018 6063 -T5 MEETING RAIL SW -40111 6063 -T5 FIXED 1---1- 1.000 1 --I 0.810 SUDER TOP SW 6063 0.592 0.050 1.00 1 1.250 l __ _ 1.437 _ _ t ^► 0.687 �--- 2.077 — FRAME JAMB SW -013 6063 -T5 I-- AND BOTTOM RAIL -012 -T5 INSERT TRACK SW -xxx21 6063 -T5 2.750 • 0.078 3.062 n 1.750 • 1.8750 MOVING 1.5090 inn. 2.00 SILL 1.0000 SIDE SW -016 6063 -T5 RAIL FRAME HEAD AND SW- 019 /SW -44287 6063 -T5 SILL RISER SW -40771 6063 - T5 MATERIAL LIST AP- ROVED AS COMPLYING WITH THE SOUTH FLORIDA BUILDING CODE DAT. BY — FItODUCT DIV :S.:::1 BUILDING CODE COMPLIANCE OFFICE ;CCEPTA "E NO 61- o r2 ' • O( FRANCISCO HERNANDEZ FLORIDA PE # 51393 Sunshine Windows Manufacturing, Inc. 1745 W. 33rd Place Mesh. Florid* 33012 Ph: 306364 - 2952 Fox:(305 -5116 Drown ey: JN Oats: 3 -9 -99 Seal.: 1 /2 " =1 " Revision :1 - 75 -OC Revision: DRAWING N0. HS99 -03 SHEET 5 OF 5 ELECTRICAL TYPE': Minimum Fee QTv. TYPE Dryer Q'I'V. TYPI. Outlet, Appliance QTV. TYPE Service Repair QTY. A/C Central 1 -3 Ton Fan Outlet, Wall Service, Temporary A/C Central 4 -7 Ton Fire Pump Outlet, Switch Signs A/C Central 8 -15 Ton Fixture - Fluorescent Oven Space Heater (kw) A/C Central 16-20 Ton Fixture Light Parking Lot Lights Spas/Hot Tubs A/C Central 20+ Ton Flood Lights Plugmold/Strip Subfeeds, No. of Amps A/C Window FPL - Load Central Posts Swim Pool, Commercial Air Conditioners Garbage Disposal Range/Range Top Swim Pool, Residential Chiller Generators, etc. Receptacles Switchboards Clear Violations Heat Recovery Refrigerator, Comm. (p/PH) Temp Serv., Construction Compactor Low -volt, Burglar Refrigerator, Domestic Temp for Test - 30 days Deep Freezer Low -volt, Fire Renew - Temp Service Water Closet Demolition Low -volt, Intercom/Teleph. Repair Circuits Water Heater Dishwasher Low -volt, Television Service, Number of Amps Water Heater New f t :CHANICAL T1 PI:. Minimum Fee (y1 Y. TYPE Condensate Drain Q'I'V. 'fvI'I.; Generator QTY. TN 1.1., Refrigeration, Tons QTV. A/C Central, Tons Cooling Tower Heating Strips, each Vent Hood, Cost A/C Wall/Win. Tons Dryer Vents, Number of Paint Booth Ventilation, Cost Air Handler, Tons Ductwork, Cost of Piping, Flammable Liquid Periodic Inspections Barbecue Fire Sprinkler System Process/Pressure Piping Supply, AC Well Bath Fan - Vented, # Fireplaces, Number of Pressure Vessel Temporary Toilet PLUMBING TYPE A/C Condensate QTY. .l.\.pE Drains, Roof QTY. TYPE Miscellaneous Fixture QTY. ' i ' vri , ; Soakage Pit Q Bath Tub Drinking Fountain Miscellaneous Repairs Solar Water Heater Bidet Filter Replace Pool Piping Sprinkler Repair Cap - Fixture Fountain Pump and Abandon Sprinkler System Cap - Water Gas - Appliance Pump, Domestic Supply, AC Well Cap - Sewer Gas - Natural Pump, Fire Stand Temporary Toilet Catch Basin Gas - Propane Pump, Re- circulate Temporary Water Closet Clothes Washer Gas Piping Pump, Replace - Pool Urinal Dental Chair Grease Trap Pump, Sprinkler Utility - Sewer Discharge Well Ice Maker Pump, Sump Utility - Water Dishwasher Indirect Wastes Relay Repair Vacuum Pump Disposal Interceptor Roof Inlet Water Closet Domestic Well Laundry Tray Septic Connection Water Heater Drainfield, 4" Tile/Res. Lavatory Septic Tank Water Heater New Drains, Area Meter Set (Gas) Sewer Connection Water Re -pipe Drains, Floor Minimum Fee Shower Water Service Drains, French Miscellaneous Equipment Sink.__ Well; Supply Page 3 PERMIT APPLICATION INSTRUCTIONS: Please indicate the type of work being performed and quantity(ies) in the space provided below. RECEIVED AND REVIEWED BY: DATE./' SECTION BY DATE Zoning Electrical Mechanical Plumbing Fire Public Works Structural Building Official SAG Page 4 OFFICE USE ONLY CHECKLIST ❑ OWNER - BUILDER FORM (Attach) ❑ FIRE DEPARTMENT APPROVAL (Commercial / multi- family) ❑ CONCURRENCY (New Construction) ❑ OTHER (Specify & Attach) ❑ PROOF OF OWNERSHIP (Attach) ❑ HRS / DERM APPROVAL (Septic / Sewer) ❑ IMPACT FEE (New Construction) ❑ OTHER (Specify & Attach) PERMIT FEES $3.00 per page (Scanning Fee) $ Miami Shores Village Bond Metropolitan Dade County (C.C.F.) $ I I? 0 Inspector State Educational Fund $ State DCA (Radon) $ Code Enforcement Fine Zoning Review REVIEWED AND PREPARED BY: (sq.ft. = x/1000 x ¢.60) (¢.005 / sq.ft.) (¢.01 /sq.ft.) PERMIT APPLICATION ❑ CONDO ASSOCIATION APPROVAL (Attach) ❑ BPR APPROVAL (Restaurants) ❑ CONTRACTOR REGISTRATION (On File) TOTAL $ ISSUING OFFICIAL DATE: CONDITION OF APPROVAL Revised July 2001 10050 N.E. 2ND AVE., MIAMI SHORES, FL • (305) 795- 2207 (305) 756 -8972 • http : / /www.miamishoresvillage.com