Loading...
WINDOWS/DOORSMy Commission Expires: APPROVED: PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Dat ✓ /" Job Address 12E3 NE 101 Street, Miami Tax Folio 11- 3205 -025 -0040 Legal Description Bay Breeze Section,Miami, Lot 5 Owner / Paul an Arlene Shannon Master Permit �� ,A / - Owner's Address 1253 NE 101 Street, Miami, FL. Contracting Co. W & D Maintenance Inc. / V" PHINE CRACK 4 .. ✓ ! d, . //d f 1 ' :Notary Public. Shia M ninth ur , •? Nifary as to Owner and/. T * * FEES: PERMIT 11 / / 6 RADON Zoning Mechanical * * * C.C.F. ,t/ Fire L Buildin g4 Phone (305) 751 -9091 Address 290 NE 79 Street, Miami, Fri 3333P Qualifier Robert Sho Sgq� Phone (305) 751 -4583 State # Municipal # Competency # CC18915 Ins.Co. Liberty Mutual Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): UULLDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION remov windows and replace same with new windows,/ Z. remove door and replace with window in the present opening Square Ft. Estimated Cost(value) 2,000.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above-named contractor to do the work stated. Signatyrg L.,owner and /or Condo President Date: // Sig of Contractor or Owner- Builder Date: cALoti . Qsi oclf Notary as to Contractor or Owner- Builder My Commission Ex? NOTARY 6r) 1resOFF1CIAL'NOTARY SEAL ERIN L ASHBROOK NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC 19910 MY Cd 4MISSIOI ! EXP. JUAE 11,199r TOTAL DUE ; Other Electrical Plumbing Engineering 600: 900 P�) METROPOLITAN DADE COUNTY. FLORIDA METROVA DE Chairman Bertram S. Nirrshua lice-Chairman 11.0 Lasseter Members Runuld .aver Inures .rout Grr,r?r Berlin Pwmat M. B lack Laurence :1 Boron Ted Bndis Osrar Brennan John Calptnt Eduardo Camel lore de !a Torrtrnre H. Carlton Decker .4 mold Goldman Richard ►f Horton Daniel Le,,rs John Lindstrom Stn en Lowe Joseph tfokher. Sr James Po,. er 14711,urn Rae .% M. Ri.o 77umius Crerba A lfred uetsb•r,d Rudy µ;lliarta Board Consultant John P,slonno Scoff Charlet Dunver Sundt uetnreb Ott DwntonJ (305) 375 -2610 PR,Q UCT_C_QNTggL NOTICE OF ACCE;T,NE inyl Tech, Inc. 155 Center Court enice, F1. 34292. our application for Product Approval of $er3.s 2590 Type (XXQ luminum. Tiding Glass Door SD -R50 under Sections 203 and 204 f the South Florida Building Code governing the use of lternate Materials and Types of Construction, and completely escribed in the plans, specifications and calculations as submitted by BFp1 cant, aloe wirdh Miami Testin Laborato_ 19, 1245 has been accepted by Product Control under the pecific conditions set forth on pages 2 -2a and the Standard onditions on Page 3 fgr•Glazed Products CCEPTANCE.No.: 92- Q]e.14.1 PROVED y 11, 1122 XPI? S Dec. 19, 12.25 THIS IS THE COYERSHEET, .SEE ADDITIONAL PAGE$ FOR SPECIFIC AND NEE,AL CONDITIONS BOARD Of:_ULES AND APPALS NOTICE Q' ACCEPTAIE his application for Product Approval has been accepted by the etropolitan Dade County Board of Rules and Appeals to be used in the Incorporated and Unincorporated areas of Dade County nder the conditions set forth above. APPROVED: May 11, 1992 - - - H >3L 'II\IA * *PLEAS$ NOT$ ** " 1 &1 METRO•DADE CENTER BOARD OF RULES MO APPEALS SUITE 1010 111 N.W. in STREET MIAMI. FLORIDA 33128-1914 (305) 375-2981 it Diamond, P.E. Product Control Division Supervisor Charles Danger, P, Secretary Metropolitan Dade County Board of Rules and Appeals 559f:LIN:HAT , 0 t :0 T C6- vv %�0 METROPOLITAN DADE COUNTY, FLORIDA ME RO.OAOE Ron''IinFdl Vinyl Tech, Inc. P.O. Box 749 Venice, Fi. 34284 -0749. Your application for Product Approval of aees " ri 2 000" T yne "XX0" Aluminum Sliding Q.lass poor SGD -C30 under Sections 203 and 204 of the South Florida Building Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by National Certified Testing Lftbor &tory ReyQX. No. NCTL - - 0116 - -2 and -3 15,.teci.,I.s3TL 29, 1990 has been accepted by Product Control to be used in the Unincorporated areas of Dade County under the Specific Conditions set forth on pages 2 -2a and the Standard Conditions on Page 3 for Glazed Products . ACCEPTANCE No.: 90 044.1 APPROVED Tune 11. 1990 EXPIRES : Jart. 29, 1994 • :RI • ; :► >, APPROVED: June 11. 1990 £RODUCT C9NT.$9L_nOLUE 07 AC ;EpTadiCE * *PLEASE NOTE ** c.M1 TI I t3S. -1- 4 117_ ; vier ,Lit M ETRO -DADE CENTER BUILDING L ZONING DEPARTMENT SUITE 1010 111 N.W. 1p S'AEer MIAMI, FLOp10A t41*.1p74 (305) 375 -2612 it Diamond, P.E. roduct Control Supervisor Metropolitan Dade County Building & Zoning Department BOARD OF RULES AND APEKAL$ NOTICE OF _ACCEPTANCE This application for Product Approval has been accepted by the Metropolitan Dade County Board of Rules and Appeals to be used in the Incorporated and Unincorporated areas of Dade County under the conditions set forth above. homes . Black, P.S. Deputy Secretary Metropolitan Dade County Board of Rules and Appeals Ha3.L_1I0.1 SS9CLLtOn T.Q, SC :01 C6 /n /Z0 600/C0021 — Yi11yl Tech _ r„ laraLluiTisaY_ OF tru r m BasiGNED A rb to . _. AAMA 1 01 -8e SGn --C30 Series "2000" Type "XXO" Dade County Approval #90- 0424.1 Aluminum Slidin g Glass Door Expires: January 29, 1994 SGD -C30 or Approved for installation up to 15. a above grade. CA tmrn u Elevation must be reduced . the coastal construction' Z( 8.8LL 5 2 F. • 15' - 1 3 /8 "'by 8 - 0" high NQ,• b Rtz F r,r A three panel T l The active doc panels measures 5' - 0 3/8" wide0byl7 - 1 s1 /ding glass e fixed panel measures 5' Pix el panel - 1 3/4" wide by 7' _ 11 1 /8" high. hi F r' the not thermally bro}en. The fixed panel secured to the hea - and sill with one 2" g Frame and exterior of the fixed pan eet in g a s til e rwit h n tw each scre ened to the plastic panel guide located at each end of each panel l sti hollow. claw - type door lock assembly located at One stile with the keepers fastened and securedlto the fixed meetn stile On and the jamb at lock positions, fixed meeting stile assembly used at each end of the panel d bottom l rails. Annext roller aluminum sill extension added to the top of s sill in place. Frame and p f the interior vertical sill screw butt . panel top rail corners of double -type corner construction. Panel bottom rail corners of single screw butt-type corner construction. A steel reinforcement measuring 3/8" 7 �, oow, Y /8" x 9l long was employed in each interlock stile A steel reinforcement measuring 3/8" x 1 1/ x 91" long employed in the fixed meeting stile hollow, a flexible Allnpanels channel glazed using 3/16" thick tempered glazing bead. Pered glass wig • H AI 1ANIA -2- ACCEPTANCE No.: APPROVED EXPIRES S59CLLfi008I,$ 6C :OT 'Jan, 29, T9< Gil Diamond, P.E. Product Control Supervisor Metropolitan Dade County Building & Zoning Department Vinyl Tech DESCRIPTION OF UNIT MODEL DESIGNATION Series 2500 Type (XXO) • Aluminum Sliding Glass Door GSD -R 50 600.'!110 (] -- -- H)31. ACCEPTANCE No.: 92- 0114,1 APPROVED EXPIRES NOTICE_ OF ACCEPTANCE: SPECIFIC CONDITIONS _May.11, 1990. Dec. 19, l9)' ASSIGNED ACCEPTANCE MARKINGS AAMA 101 -88 SGD -R50 Dade County Approval #92- 0114.1 Expires: December 19, 1995 Approved for installation up to 75. above grade. CA3TI.N: Elevation must be reduced the coastal construction z' DYLE$LL SIZE: 12' - 3 7/8" by 9' - 0" high No, SIZE_OZ_PAUEL45a Three, two moving, (XXO as viewed from the exterior): from the left, 50 1/4" by 107 1/16" high 50" by 107 1/16" high; 50" by 107 1/16" high. HEATHEEETRTPPING: Double pile in each frame jamb, each top rail an7i bottom rail, in the female astragal stile and in each interlock stile (UFpATO & LOCATIONS: One adjustable metallic wheel at each end of each bottom rail. One flush mount metallic lock at each lock stile. One 3/16" diameter steel security lock pin through the interior inter stile, into the exterior stile, 80" from the bottom. (Security pin not required for two panel door.) G1.AZ TNG MATj RIAL: 3/16" tempered glass. GLAZlI METHOD; Channel glazed using a flexible channel vinyl glazi:: bead. WEEPHQLESL One 1" notch in each end of screen track. One 1 3/8" r.= in each end of each moving panel track. 5.1a=St None JE1 FOR One 1/2" by 1 1/4' aluminum bar inside each interlcc stile. One 1/4" by 1 1/4" and two 3/8" by 1 1/4" aluminum bars insid the female astragal stile. Gil Diamond, P •'E . Product Control Divs`C.. cc9C1.2.1 If :UT C6•'ZZ' O Vinv 1_ T2�h, Ync. ACCEPTANCE No.: 90 -04 4 1 APPROVED : _,LLU1e 1 19 o r EXPIRES ran 29 aq TIOTTCE OF ACCE_ p_ TA�N�£. q F TFTr WEATHFpSmRTP2T41 A double stri of located at each P polypile weatherstrip (.200" high jamb and the fixed meeting stile. A single strip of polypile weatherstrip (.200" high) located at each interlock stile. double strip of polypile weatherstri A top and bottom rails. An adhesive P (• high) located at each pan. 1" ve back polypile dust lu I x 1 1/2" located at the head and sill track at the rlock measurin e meeting stile. WEEPHQyi One weep notch measuring 1 1/ 4 end of the sill screen and roller tacks x le height located at eac SEATA NT. Frame corners were sealed with a small joint sealant. aCREE.al An insect screen measuring 5' - 0" wide by 7' - 17 - hih butt type employs fiberglass mesh cloth with a hollow vinyl one plastic pull handle; one flexible vinyl weatherseal, spring - loaded meta roller type retainers. T.ES TS : i�BE_ANt7 MF ^HGD Or LTTwri * +*+ rn INTERIOR WINDLOAD: 45.0 psf SILL . 24 #10 x 1" FH CP SMS EXTERIOR WINDLOAD: 45.0 psf HEADER: 24 ° 10 x 1 # FH CP SMS WATER RESISTANCE 9.20 psf JAMBS : 12 #10 x 1" FH CP SMS AIR-r INF ILTRATION ; 0.37 cfm /sf FORCED ENTRY : NCTL- 210 - 0116 -2 i P1e S@s, Note u Paae 15. ft, above existing grade This product must be re evaluated for structural adequacy when in within the Coastal Construction Zone in accordance with Chapter �talle 3 Sub - section 2309.2 (b) of the South Florida Building Code. it Diamond, P.E. roduct Control Supervisor etropolitan Dade CountV - Vinyl Ieah_ FORCED ENTRY APPROVED FOR ELEVATIONS_ UP TO ACCEPTANCE No.: 92- 0114.1 APPROVED : May 111. 199 EXPIRES • • - e •► Dec. 19, 19 ADDITIONAL DESSRIPTION: A 2 1/2" high overall interior sill flange Fixed panel anchored to frame jamb using six plastic anchor clips, 9 from each end and on 18" centers, each hooking to frame jamb and sec to stile with one No. 8 by 3/4" screw. One 1 3/4" by 1 3/4" by 1 1 by 1/4" aluminum angle at top of fixed interlock stile, secured with No. 8 by 1" sheet metal screws into frame head and one, plus two pan assembly screws into stile. Cne 1.70" by 1.70" by 1.70" by 1/4" alu angle at bottom of fixed interlock stile, secured with four No. 8 by sheet metal screws into frame sill and two, plus one panel corner assembly screw into stile. One 1 3/4" by 1 3/4" by 1 1 /8" by 1/4" aluminum angle at top of female astragal stile, secured to stile usi one No. 8 by 1" screw and two panel assembly screws. One 1" by 5/8" 4" long aluminum retainer angle in frame head at female astragal sti on the exterior, secured to frame using four No. 8 by 1" screws ". C by 1" by 4" by 1/8" aluminum angle in frame sill at midspan of fixed panel bottom rail on the interior and exterior and one at midspan of moving panel bottom rail on the exterior, each secured to frame sill using four No. 8 by 1 "' sheet metal screws. TRSTS: SCREW AND MFI$OD F ATTACHMj' INTERIOR WINDLOAD: 76.0 psf SILL : D.R., 11 - *10 x 1" FH EXTERIOR WINDLOAD: 76.0 psf HEADER: D.R., 11 - *10 x 1" FH WATER RESISTANCE : 9 :10 psf JAMBS : D.R., 9 - *10 x 1" FH AIR INFILTRATION : 0.36 cfm /sq. ft. .MTL 15095 2IQTE_: Rlease see UQte . . • - - . , • • • • - This product must be re- evaluated for structural adequacy when insta within the Coastal Construction Zone in accordance with Chapter 23 Sub - section 2309.2 (b) of the South Florida Building Code. i r. ^ n r : E 600/800e H311, i:INI.1 9L'LLroO5T$ ZrOT L'6 /ZZ /Z0 REvLSI';11 r, - 18 -yL �'i- L�S�E L?�1a.G�EP1a�IS�E= S1'AI�UAIiU C:VNI)I'1'IVNS _EU1t._ Ca LAZELL1 flQL.U(''1S 1. For multiple window 111Atn11ntions, npprc,yeti mullion elm vingn anti enlcu1utiortrr must I filed with Product Control. 2. 'liras ncceptnnce will qualify smaller units of the aortic design nod ntnLer•iuls us 1.1 uni tested. 3. All units___n1tLt ,. latzele L_ EUUe_ t► l__ nia .tutfno.tutecLs_ttaikte._J)atle Cotinky_Ljuciui Control Approval Xtttnber a pj. i j,f Pjtjan and date of. expiration 4. Extension of Acceptance may be considered after n new ttpplicuLiurt has been file and the supporting data, for test reports less than four (4) yenrs old, 1ms been re evaluated. G. Any revision or change in tnntet•inIR. ogc or nuuru roc Lot r nr the product raltn nutrrnrrtLiertlly be cause for I.CrtnirutLion, 'miens prior rtl,Irrlrvnl in grouted for rtevisio or change. 6. Any utlentiefncLory performance be grounds for re- evaluntwn. Of LItiR (1rrlt111c;I or' n Oiling(' in ('orlr (rr•nvivionq RIM 7. This nccept.nnee plrrcll not be trsetl no nn endorsentenl of fife product. sides o Rdver'tieing purposes. 8. Windows and eliding doors hove been tested in nccureluuce with the Americo' National Standards Institute's specifications mil the Arclti Lee turn! Alurninun - Mnnu Inc hirer's AB5ucir>tion Stnntlnr•ds AN$1 -AAMA I O1 -R!; or for . wood unit ANSI /AAM 302 and 402 and for vinyl units •ASl'M I) 4099 - 82. 9. Swinging doors shall be tested for positive and tlegriLive wind pressures us pe Chapter 23 of the South Florida 13ullding Code. 10. 1Jnrdwnre for all windows and doors shall eon form Lo Intrusion anti Iitrrglnry Securit,} (Ampler 8C; of the (:ode of McLropoliLnn, 1)riclr ('oonly. 11. The spacing of fasteners shall be its tested or 24" whichever Is less. Lam.III:gt,��l$t C ILIII I���Q4 8SLILJtI [t1(111i1IAt1...Vf�i _ ectc:tl_s;ocuer nncl r,tull ic,ti or stile. Minimum Ilene trnLion of fnstc^ner shrill be ns tested or :1/4" whichever ir= higher. No wood or plastic shields or pits sirup be used. 1300 5(rr:r E Unlens otherwise noted In the Lest report, minimum sire of Rc:IOWA shat! be No. 8 for first nntl second f!nor Instnllndons noel No. 10 (or nil other floors nl,ovc the fir t. nntl second floors. '( 1 I)inuto I'rochieL Con Lrol Division Supervisor H,3L Z.i \I.1 559CLL1'1". PROGRESSIVE .GLASS .TECH ID :813 -484 -7502 . METROPOLITAN DADE COUNTY. FLORIDA METRO•DADE Chairman H, 'Matt S Ilirrlhu , lire - Chairman 11(1 n, 1lernben k , ardd .4 re'r l.emr1 Ards Ge''rQ• Ream Thomas .11. Black g,r{ar; Ted Rndic (1scar (ire Joiut Culp,n, EJucrdo C„nt1 lure• de la Terrreenre H. Carlton Decker .4 mold Goldman Richard 31. Horton Darrel Lewis John 1.endstreom Steven G; n ,r Joseph Slukher Sr James Po■er William Rehr 4 nnandu 5'l R■: Thomas (u rh,,, ; Alfred 4e•6hr, k,.,i, 44 iNntrn.< Board Consultant John P,chalno Staff Churls Dan Solid liwnreb 6,1 Diamond Vinyl Tech, Inc. 155 Centor Court Venice, F1. 34292. Your application for Product Approval of Series 400 Colonial Aluminum Awning Window A -C30 under Sections 203 and 204 of the South Florida Building Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by Lip .an along :11 - • _ 0" • • has been accepted by Product Control under the Specific Conditions set forth on pages 2 -2a and the Standard Conditions on Page 3 for ACCEPTANCE No.: 92- 1113.3 (911 APPROVED EXPIRES (305) 375 - 2610 pRPD11CT CONTROL NOTICE OF ACCEPTABCE = Marsh 6 1992_ April 1Q, 1995 ** APPROVED* March r•1 ERAT. CONDITION. -1- JAN 15'93 12:10 No.012 P.01 41 /t d 40 41 METRO -DADE CENTER pi.F'ASE NOTE * * M BOARD OF RULES AND APPEALS SuITE 1010 111 N W. 1s1 STREET MIAMI. FLORIDA 33128.1974 (305) 375.2981 Gil Diamon•, P.E Product Control 'ivision Supervisor : 11 , ; P • This application for Product Approval has been accepted by the Metropolitan Dade County Board of Rules and Appeals to be used in the Incorporated and Unincorporated areas of Dade County under the conditions set forth above. Charles Danger, . Deputy Secretary Metropolitan Dade County Board of Rules and Appeals ROGRES S I VE . GLHS` . TECH ID ::: :13 - =:1 1 -7502 V�pyl Tech. .Inc . pESCRIPTION OF UNIT MODEL DESIQN4TION Series 400 Colonial Aluminum. Awning Window A - C30 OVERALL SIZE 4' - 5 1 /8" by 6' - 4 1/8" high NO. &ZE OF VENTS 1 nnflT'r DESCRIP.T=13_ HN 15 L, 12:11 No.U1: r'.U2 ACCEPTANCE No.: 92- 1113.3 (911 APPROVED EXPIRES March 16. 1992 April 10. 1995 ASSIGNED ACCEPTANCE MARKINGS AAMA 101 -88 A -C30 Dade County Approval #92- 1113.3 (91) Expires: April 10, 1995 Approved for installation up to 15. ft. above grade. CAUTIOS: Elevation must be reduced in the coastal construction zone Five, each 52 3/16" by 15 5/16" high. WEAT$ERSTRIPPINGt Double vinyl bulb in frame head, jambs and bottom rail of the four top vents. Single vinyl bulb in frame sill and bottom vent, bottom rail. OCATIONS: Roto operator. Automatic metallic hook lock in frame jambs at each side of each vent; a 3/16" by 1/2" lock pin in each jamb rail of each vent, 8 3/4" from bottom corner of vents. GLAZING MATE,RIAL.3. Double strength annealed. GLAZING METHOD: Exterior glazed using silicone adhesive and rolled aluminum glazing bead. WEE .UQi+ES : None 4UNTINS: Four vertical muntins per vent; twenty five light .EINFORCEMENT: None Flange type frame -2- Gil Diamond, P.E. Product Control Division Supervisor colonial. F'ROGRESSI VE . GLHSS . TECH ID: G13 -4i4 (Ju2 yinv7. Tech. Ine. ,_ ACCEPTANCE No.: 92 -1113 3 (9L1__ APPROVED March 16._1192 EXPIRES April 10. 1995 • •%0 •k •••• • ; • � 0 V v09 • • V 1. TE Ti : INTERIOR WINDLOAD: 45.0 p.s.f. EXTERIOR WINDLOAD: 45.0 p.s.f. WATER RESISTANCE : 8.30 p.s.f. AIR INFILTRATION : 0.04 cfm /s.f. FORCED ENTRY MTL 14801 (FER) Z'1SYT,E3 P ea a ee No #11. paoe 3 SILL : 3 - #10 x 1 1/2" FH SMS HEADER: 3 - #10 x 1 1/2" FH SMS JAMBS : 3 - #10 x 1 1/2" FH SMS r fpF+t above e;= � °'' { na grade product roduct must be re - evaluated for structural adequacy when installe< within the Coastal Construction ut , he Florida o 8uild i ng 1 Code Chapter 23 Sub - section 2309.2 (b) of the So -2a- Gil Diamond, P.E. Product Control. Division Supervisor JHCd 1 yi 1L•lL7\10.U1Z f'.U4 1tl' ;vLSr,1) 8- 18 -91. LLQ77('x OF AC`C'EP1AN ,1_;; S ANDAI I) CUNI) ' ' 11.S.LrC211,.S.11.AZEll !'RL2MJS1'.I I 1. For multiple window installations, approver] mullion drawings and calculations must be filed ' with Product Control. 2. This acceptance will qualify smaller units of the same design and materials as the unit tested, County _Rush= ,g, AIL units must _be labeled. gtYi11 - 1C Ala 1 Ocher. aoprov0_eleva tion 4. Extension of Acceptance may be considered after n new l�) ieii tcm h n A be fil and t the supporting data, for test reports less than i.c evaluated. I. 8111111 G. Any rovlsiott or chtu►ge r termination, unless is of granted fo � automatically be (muse for or change. I'RUGRESSIVE .GLASS .TECH Ill : 813 - 464 - r5U2 of thin product or.. n change in Code provisions shall g. Any unentisfnctory performunce be grounds for re- evaluation. 7. This ncceptance shrill not be used as nu endorsement of any product sales or advertising purposes. g. Windows and eliding doors IQ veH � e c ei i f c,at eated anti accordance t] the Architectural c hilt r Aluminum ) Na tional Standards institute l Manufacturer's Association Standards units 1 A M - 815 or for wood unto A, ANSI /AAM 302 and 402 and for vinyl 9. • Swinging doors (shall be tested positive and newt Live wine] pressurem RR per Chapter 23 of the South Florida Building 10. I:Inrdwnre for all windows and doors shnll conform t11 o. Intrusion and Burglary Security ChnpLet' 80 of the (.ode of Metropolitan Dude 11. The spacing of fasteners shall be as tested or 24" whichever is less. I1 1:11e. [ irflf_1alttenex ._ill1a11_1.0...1osgaxs:tl a..ULUW1 - and milli ion or stile. Minimum penetration of fastener s bbeuas as or 3/4" whichever. is higher. No wood or plastic shields or p Unless otherwise noted In Lite test report, t,d min imum l (1 for all o R flo o ra l b N e for first and second floor )Hato first and second floors. -3- CBI 1)1n pond, 1'.IJ. Product. Control Division Supervisor PROGRESSIVE.GLASS.TECH ID :813- 484 -7502 JHN 1 ,)'93 12:12 NO.U12 N.U� METROPOLITAN DADE COUNTY, FLORIDA METRODADE Vinyl Tech, Inc. 155 Center Court Venice, F1. 34292. Your application for Product Approval of Series 400 Aluminum Dual Fr-a: nM•Ining Wind ww A. 4 under Sections 203 and 204 of the South Florida Building Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications am calculations as submitted by 6.' -11 "- -I' owe \• including PER dated April 12, 199S has been accepted by Product Contro Co be used set the forth 2 and the Dade Standard Conditionsthe Specif on Page Condition for Glazed Pgoducts ' ACCEPTANCE No.: 90-0807.3 APPROVED Sept. 10. 1990 EXPIRES . THIS IS THE COVERSHF APPROVED: . September 1St. 19 PRODUCT CONTROL NQICE OF ACCEPTANCE * *pyEASE NOTE ** CONDITIONS - 4 00 0 METRO•DADE CENTER BUILDING & 10141110 DEPARTUENT ' SUITE 1010 111 N.W. 1,1 STREET MIAMI, FLORIDA 3312 &1974 :•.:I • :►� : • ∎• �, (305) 375 -2612 i1 Diamond, Control Supervisor Metropolitan Dade County Building & Zoning Department • ; P P • \ : This application for Product Approval has been accepted by the Metropolitan Dade County Board of Rules and Appeals to be used in the Incorporated and Unincorporated areas of Dade County under the conditions set forth above. Tho omas - M. Black, P.E. Deputy Secretary Metropolitan Dade County Board of Rules and Appeals PROGRESSIVE.GLASS.TECH ID :813 -484 - 7502 ns SCZi T ION QF UNIT Series 400 Aluminum Dual Frame Awning Window A -R30 NOTICE OF kCCCEPTANC$ L SPECIFIC CONDITXQNS ASSI ED ACCEPTANCE MARKING AAMA 101 -88 Dade County Approval #90- 0807.3 Expires: April 12, 1994 Approved for installation up to 15. f above grade. DYELIALL_ISIZEI c'nii� T.� I0N1 Elevation must be reduced i the coastal construction'zo Sub - frame, 53 1 /8 " by 50 5/8" Window Frame 51 3/ 4 by Y 5/8 Ha. &_ SI1Z. OP' VENTS: Three, each 50 WFATKRRSTRIPpING; Double vinyl bulb and in bottom rail of top and center sill and bottom rail of bottom vent. • Moto operator; automatic metallic hook lock in frame jambs at each side of each vent; a 3/16" diameter lock pin in eac jamb rail of each vent, 9" from bottom corner of eachd vent. One om b om loco in ottom of jamb, lockin 9 the lamb, out - swinging awning window frame to the out bmb, frame. g lahaira MATFRIAI ,Double strength annealed glass. GLAZING TKOD, , Exterior glazed using clear adhesive bedding compound and rolled aluminum glazing bead. WEx HOL .S: None WINTINS ; None gEINFORCEMW: None -2- JHH ACCEPTANCE No.: APPROVED EXPIRES r.Gv 90- 0807.3 Sept. 19, 199 : April IL 1994 4 3/4" by 16 1/2" high. in awning window frame head, jambs vent. Single vinyl bulb in frame it Diamond, P.E. Product Control Supervisor Metropolitan Dade County Building & Zoning Department ROGRESSIVE.GLASS.TECH ID :813- 484 -7502 JAN i 'D'93 12:13 No V.U( vinyl Tech, Inc. ACCEPTANCE No.: 90- 09073 j�QTI..CF��F ACCEPTANCE;_ SPECIYIC CONDITIONS TESTS: ,SCREWS AND araliOD OF ATTACHMENT ' INTERIOR WINDLOAD: 45.0 p.s.f. SILL 3 # 10 x 1 1/2" FH CP SMS EXTERIOR WINDLOAD: 45.0 p.s.f. HEADER: 3 # 10 x 1 1/2" FH CP WATER RESISTANCE : 4.50 p.s.f. JAMBS : 3 # 10 x 1 1/2" FH CP SMS AIR INFILTRATION : 0.17 cfm /sf. FORCED ENTRY : MTL 14351 tIQTEl Please see Note #11, Page 3 • ; • / , • •k 15 feet above existing grade This product must be re- evaluated for i structural a de q u a c y hw henx in s talled within the Coastal Construction Zone Sub - section 2309.2 (b) of the South Florida Building Code. -2a- APPROVED Sept. 10. 1990 EXPIRES Aprik_12, 1994 it Diamond, P.E. Product Control Supervisor Metropolitan Dace County Building & zoning Department 3. 1 J J J • :►P:; I •► IVY •► J•; e p •;•1 1. For multiple window installations, approved mullion drawings and calculations must be filed with Product Control. 2. This acceptance will qualify smaller unite of the same design and materials as the unit tested, 4, Extension of Acceptance may be considered after a new application has been filed and the supporting data, for test reports less than four (4) years old, has been re- evaluated. 6. Any revision or change m materials, use or manufacture of the product shall automatically be cause for termination, unless prior approval is granted for revision or change. 8. Any unsatisfactory performance of this product or a change in Code provisions shall be grounds for re- evaluation. 7. This acceptance shall not be used as an endorsement of any product sales or advertising purposes. 8. Windows and sliding doors have been tested In accordance with the American National Standards Institute's specifications and the Architectural Aluminum Manufacturer's Association Standards ANSI -AAMA 101 -86 or for wood units ANSI /AAMA 302 and 402 arid for vinyl units ASTM D. 4099 -82. 9. Swinging doors shall be tested for positive and negative wind pressures as per Chapter 28 of' the South Florida Building Code. 10. Hardware for all windows and doors shall conform to Intrusion and Burglary Security Chapter 8C of the Code of Metropolitan Dade County. 11, The spacing of fasteners shall be as tested or 24" whichever is less. A The first fj.staner shall Jae locayed_a_Alialiimam_saLALI,rom each corner and mullion or stile. Minimum penetration of fastener shall be as tested or 8/4" whichever is higher. No wood or plastic shields or pins shall be used. Unless otherwise noted in the test report, minimum size of' screws shall be No. 8 for first and second floor installations and No. 10 for all other floors above the first and second floors. -3- it Diamond, Product Control Division Supervisor 1L.14 ivu.u12 ►'.08 REVISED 6 -18.91