Loading...
RC-06-384 �R Inspection Worksheet At . Miami Shores Village j � 10050 N.E. 2nd Avenue Miami Shores, FL R � • rR6 � Phone: (305)795 -2204 Fax: (305)756-8972 Inspection Date: 03/03/2008 Permit Type: Residential Construction Inspector: Dacquisto, David Inspection Type: Survey Final Owner: ALTERMAN, RICHARD Work Classification: Addition Job Address: 1247 101 Street NE Miami Shores Village, FL 33138- Phone Number (305)759 -3460 Parcel Number 1132050250050 Project: <NONE> Block: Lot: Contractor: FLORIDA PROFESIONAL SERV LTD CO Phone: 305 - 759 -3460 Building Department Comments EXPANSION OF EXISTING BEDROOM AND EXISTING BATHROOM. NEW DOORS AT FAMILY ROOM, NEW KITCHEN CABINETS, NEW FRONT ENTRANCE, STEPS AND RAMP. Inspector Comments Passed Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled until re- inspection fee is paid . Monday, March 3, 2008 Page 2 of 2 IF 5582 N. W. 7th STREET SUITE 202 • • . • • • • • • s ,.. SURVEY No. 5 - 0002903 -5 MIAMI FLORIDA 33126 * • • ' } �.r' ¢ g� TELEPHONE: (305) 220.3171 ;Via V' a : i� t W A2 � .+7 n r • FAX: (305) 2640229 ' ' ' ' ' : • LAND SURVEYORS • • SHEET No 2 OF 2 DRAWN BY: T.D. ArIL . : SC&E 4 20: : •• • • • •e ••• •• L • : : ••• : : :•• •e LOT-3 LOT -4 B BLOCK -186 BLOCK -185 o 10.03 9.98 9.93 .I.P 112" 10.30 86. 0` U� 10.05 I .I.P 112" NO GAP CAP ONP.L 900 ( X + 4'C.L.F. x 5'U.E. + ON P.L. _ 10.33 • ��/% 10.20 LLLLLI� LLLLLLLLLLLLLLLLLLLLLLLLL r �, 930 V # 10.01 x LL tL,.,LL 10.30 % ��� 1 09 LL POOL L► 10.00 .13 10.30 % x LL�,Ltz 37.60' LLL 7us 10.03 L LLL %�- J LLLLL LL x CU % LLLLLLLLLLLLLL LLL LLLL LL V LLLLLLLLLLLLL LLLLLLLLLLLLLLLLLL u : LL �� LLL LLLLLLLLLLLLLLL 9.46 LL tt� LLLL L LLL LL LL L 9.01 U LLLLL LLLL 'v L C.P. % 9.00 10.20 8.60 p 9.53 46.20' 50 X O + •99 % ONE STORY RES. # 1247 19.65 880 LOT -6 5.65' BLOCK-185 x 8.85 LOT- 5 LOT-7 L.F.E =10.34' ti BLOCK 185 BLOCK 185 ONRL F.F.E =11.18' Sri 1.50 CL GARAGE ELEV. =8.90' " X 9.83 p 19.85' + 8.72 A/C ELEV. = 8.89 + C/P N �i '.y.• '.:: A/C ELEV. = 8.89 AA� 12.35' 15.45' 1.0' CL 9.10 + 12.25' 'T11,E: , 9.97 1.80' CL - 1 :. + 8.82 :.. 8.68 C t 9.00 x 8.81 } •: -\x 7.98 8.50 8.70 +: 8.81 ` 4 8.40 8.72 x Zi X 8.62 020 &70 8.35 . x � - 8.78 .+, 7.27 a " 7.00 O �s 3 AS • 6 + 10000' : ` ,�, : � t .. ± '• =' 86:OQ' �+ f7 M F.I:P 41Z • ; j NO - 11-20j" ` " " "• %7<39' :' z. '1 =.I:P:1%P". �. CAP • .•' :...� �::. :�.s�8. ..,'• .$ :GB. . ,:;•" .;, .13.60• .s: `•d3.36�' 24' PINY 7.47 7.45 7.20 6.97 SURVEYOR'S NOTE: There may be Easements recorded in the Public Records not sh OA this Survey. a • 5562 N.W. TTH STREET SUITE 202 5- 0002903 -5 MIAM4 FL 33128 (]�/� (� • • SURVEY NO TELEPHONE' (305) 264.2660 Nova "'� ✓�, � v• FAX: (305) 2640228 i• e i • i DRAWN BY: T.D. LAR15 SUF&OdAb • • SHEET NO OF 2 SURVEY OF LOT 6, BLOCK 185, OF BAY BREEZE SECTION MIAMI.SHORES, ACSORDINGI TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 42, PAGE 25, OF THE PUBLIC RECORDS OF MIAMI- 1% • • e i PROPERTY ADDRESS: 1247 NE 101 ST, MIAMI SHORES, FL 33138 FOR: RICHARD C. ALTERMAN • • • • • : • •: • • • : : • • • • •• • • • • ••• • LOCATION SKETC�l 5 4 vy�,� 'fit 1 �-. 1 - -- ligz'r- O ��vu.eaa ere T 0 8 7 k . j 3�3�9YF' IJ7.5 ' PROPERTY ABBREVIATION AND MEANING LEGEND TYPICAL A - ARC FNIP. - FEDERAL NATIONAL INSURANCE RAD. - RADIUS OF RADIAL —ON- OVERHEAD UTILITY LINES A/C = AIR CONDITIONER PAD PROGRAM RGE. = RANGE A.E. - ANCHOR EASEMENT IN.B.EG. - INGRESS AND EGRESS R.P. - RADIUS POINT 23= C.B.S. =WALL (CBWI AIR = ALUMINIUM ROOF EASEMENT R.O.E. - ROOF OVERHANG -x--* C.L.F. - CHAIN LINK FENCE Af$ = ALUMINIUM SHED L.F.E. - LOWEST FLOOR ELEVATION EASEMENT ASPH. = AN ASPHALT L.M.E. = LAKE MAINTENANCE EASEMENT R - RIGHT -OF -WAY -0-0- I.F. - IRON FENCE B.C. =BLOCK CORNER L.P. - LIGHT POLE SEC. = SECTION B.C.R. = BROWARD COUNTY RECORDS M. = MEASURED DISTANCE S.I.P. - SET IRON PIPE L.B. #6044 -rMf W.F. - WOOD FENCE B.M. = BENC14 MARK M/H - MANHOLE SWK = SIDEWALK B.O.B. - BASIS OF BEARINGS N.A.P. - NOT A PART OF T - TANGENT • on - EXISTING ELEVATIONS C = CALCULATED NGVD - NATIONAL GEODETIC VERTICAL TWP - TOWNSHIP C.B. = CATCH BASIN DATUM U.E. - UTILITY EASEMENT C.B.W. - CONCRETE BLOCK WALL N.T.S. - NOT TO SCALE U.P. - UTILITY POLE SURVEYOR'S NOTES CH - CHORD O.H.L. - OVERHEAD UTILITY LINES W.M. - WATER METER 1) IF SHOWN, BEARINGS ARE REFERRED TO AN ASSUMED CH.S. - CHORD BEARING O.R.B. - OFFICIAL RECORD BOOK W.R. = WOOD ROOF MERIDIAN, BY SAID PLAT IN THE DESCRIPTION OF THE CL - CLEAR 018 = OFFSET W.S. - WOOD SHED PROPERTY. IF NOT, THEN BEARINGS ARE REFERRED TO C.L.F. - CHAIN LINK FENCE OVH. - OVERHANG 4� - ANGLE COUNTY, TOWNSHIP MAPS. C.M.E. - CANAL MAINTENANCE P.B. - PLAT BOOK 2) THIS IS A SPECIFIC PURPOSE SURVEY. EASEMENTS P.C. - POINT OF CURVE A =CENTRAL ANGLE 3) THE CLOSURE IN THE BOUNDARY SURVEY IS ABOVE CONC. - CONCRETE P.C.C. = POINT OF COMPOUND CURVE ffi - CENTER LINE 1:7600 FT. C.P. :CON PORCH PL. = PLANTER 4) IF SHOWN, ELEVATIONS ARE REFERRED TO C.S. - CONCRETE SLAB P.L.S. - PROFESSIONAL LAND MONUMENT LINE MIAM4DADE COUNTY. D.E. - DRAINAGE EASEMENT SURVEYOR D.M.E. -. DRAINAGE MAINTENANCE P.O.B.. - POINT OF BEGINNING ALL ELEVATIONS SHOWN ARE REFERRED TO • EASEMENTS P.O.C.. = POINT OF COMMENCEMENT NATIONAL GEODETIC VERTICAL DATUM OF 1929 DRIVE - DRIVEWAY P.P. = POWER POLE MIAMI DADE COUNTY BENCH MARK NO. B -28-RA ENCR. - ENCROACHMENT P.P.S.. =POOL PUMP SLAB LOCATOR NO. 3260, ELEVATION 17.24 FEET OF E.T.P. - ELECTRIC TRANSFORMER PAD P.R.C. = POINT OF REVERSE CURVE N.G.V.D. OF 1929 F.F.E. - FINISHED FLOOR ELEVATION PRM - PERMANENT REFERENCE F.H. -FIRE HYDRANT MONUMENT F.I.P. - FOUND IRON PIPE PT. - POINT OF T A N GENC Y JS�RVEYOR'S CERTIFICATION F.I.R. - FOUND IRON ROD PVMT. - PAVEMENT F.N. - FOUND NAIL PWY - PARKWAY I HEREBY CERTIFY: THAT THIS "BOUNDARY SURVEY" OF F.N.D. - FOUND NAIL 8 DISK • R. - RECORD DISTANCE THE PROPERTY DESCRIBED HEREON, AS RECENTLY SURVEYED AND DRAWN UNDER MY SUPERVISION, LEGAL NOTES TO ACCOMPANY SKETCH OF SURVEY (°SURVEY"): COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS AS SET FORTH BY THE FLORIDA BOARD OF THERE MAY BE EASEMENTS RECORDED IN THE PUBLIC RECORDS NOT SHOWN ON THIS SURVEY. PROFESSIONAL LAND SURVEYORS IN CHAPTER 81017 -8, THE PURPOSE OF THIS SURVEY IS FOR USE IN OBTAINING TITLE INSURANCE AND FINANCING, AND SHOULD NOT BE FLORIDA ADMINISTRATIVE CODE PURSUANT TO 472.027, USED FOR CONSTRUCTION PURPOSES, FLORIDA STATUTES. EXAMINATIONS *OF THE ABSTRACT OF TITLE WILL HAVE TO BE MADE TO DETERMINE RECORDED INSTRUMENTS, IF ANY, AFFECTING THE PROPERTY. THIS SURVEY IS SUBJECT TO DEDICATIONS, LIMITATIONS, RESTRICTIONS, RESERVATIONS OR EASEMENTS OF RECORD, AND LEGAL DESCRIPTIONS PROVIDED BY CLIENT OR ATTESTING TITLE COMPANY. BOUNDARY SURVEY MEANS A DRAWING AND / OR A GRAPHIC REPRESENTATION OF THE SURVEY WORK PERFORMED IN THE FIELD, COULD BE DRAWN AT A SHOWN SCALE AND / OR NOT TO SCALE. BY EASEMENTS AS SHOWN ARE PER PLAT BOOK, UNLESS OTHERWISE'SHOWN. (DA TE — THE TERM T' "ENCROACHMEN MEANS VISIBLE AND ABOVE GROUND ENCROACHMENTS. ARCHITECTS SHALL VERIFY ZONING REGULATIONS, RESTRICTIONS AND SETBACKS, AND THEY WILL BE RESPONSIBLE FOR SUBMITTING PLOT PLANS WITH THE CORRECT INFORMATION FOR THEIR APPROVAL FOR AUTHORIZATION TO AUTHORITIES IN NEW CONSTRUCTIONS, UNLESS OTHERWISE NOTED. THIS FIRM HAS NOT ATTEMPTED TO LOCATE PROFESSIONAL LAND SURVEYOR NO. 2534 FOOTING AND /OR FOUNDATIONS. STATE OF FLORIDA (VALID COPIES OF THIS SURVEY WILL FENCE OWNERSHIP NOT DETERMINED. BEAR THE EMBOSSED SEAL OF THE ATTESTING LAND THIS PLAN OF SURVEY HAS BEEN PREPARED FOR THE EXCLUSIVE USE OF THE ENTITIES NAMED. SURVEYOR). HEREON, THE CERTIFICATE DOES NOT EXTEND TO ANY UNNAMED PARTY. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ACCURACY OF THE INFORMATION BELOW. THE LOCAL F.E.M.A. AGENT SHOULD BE CONTACTED FOR VERIFICATION. THE FNIP FLOOD MAPS HAVE DESIGNATED THE HEREIN DESCRIBED REVISED ON: LAND TO BE SITUATED IN ZONE: AE COMMUNITY/PANEL/SUFFIX 120852 0083 J DATE OF FIRM: 07/17/1995 BASE FLOOD ELEVATION: 8 FT. REVISED ON: CERTIFIED TO: RICHARD C. ALTERMAN _ N OE IS *O��pTiFl�gr.'Q�* I NE NO.283 4 : • tav r : STATE OF . lq;rG. � SUM1 SURVEYOR'S SEAL S r 4 U.S. DEPARTMENT OF HOMELANP SE ELEVATION CERTIFICATE OMB No. 1660-0008 Federal Emergency M I a ey! �A [@� • • • • • • • • • • • Expires February 28, 2009 National Flood Insura r N p • • ' • ' • • • • rtarZt. f2eadhe l�1� op page 1 - 8. C.O.R. = 7.75 FEET 5- 0 0 02 9 0 3- 5 SEC'CIOMAz"P'R ©P£R'I Y IIdFORMAT O For Enstttanae Company Ube Al. Building Owners ame tm, p pll WOW U RICHARD C. ®� • . ^. . ,'z ••• • L A2. Building Street Ad ss in uding Apt., Unit, Suite a+>ZU - $r .Rs �hd�Bbbac ompany NAI dMbe 1247' NE 101 ST • • • • • • • City State ZIP Code MIAMI SHORES" ^ „ FL 331'i A3. Property Description (Lot and Block Numbers, Tax Par al ert a Folio#: 1132050250050 'Lot 6, Block 185, of BAY BREEZE SECTION M dYd: td the plat thereof as recorded in Plat Book 42, Page 25, of the public records of MIAMI -D y ;Erf "' y� ' A4. Building Use (e.g. Residential, Non - Residential, Addition, , ` ssory, a c.) IAL A5. Latitude /Longitude: Lat. 25° 52' 06.03" Long. 80 10 19.88" Horizontal Datum: NAD 1927 X NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 8 A8. For a building with a crawl space or enclosure(s), provide: A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) 1223.0 sq ft a) Square footage of attached garage 22 0.00 sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade 5 walls within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b 655.00 sq in c) Total net area of flood openings in A9.b N A sq in SECTION B FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State MIAMI SHORE 120652 MIAMI -DADE I FL B4. Map /Panel Number B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone Date Effective /Revised Date Zone(s) AO, use base flood depth) 12025CO093 J 07/17/1995 03/02/1994 AE 8 FT B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. FJFIS Profile ❑X FIRM Community Determined F1 Other (Describe): Bl 1. Indicate the elevation datum used for BFE in Item B9: ® NGVD 1929 EJNAVD 1988 0 O ther (Describe) B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? nYes [!]No Designation Date: CBRS DOPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: Construction Drawings* Building Under Construction* [!] Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Al -A30, AE, AH, A (with BFE), VE, V1430, V (with BFE), AR, ARIA, AR/AE, AR/A1 -A30, AR/AH, AR/AO. Complete Items C2.a -g below according to the building diagram specified in Item AT Benchmark Utilized MDC B.M.# B -26 -RA LOC 3250 NE Vertical Datum NGVD 1929 Conversion/Comments N/A Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor) 10.34 [!]feet n meters (Puerto Rico only) b) Top of the next higher floor 11.18 ❑X feet nmeters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V zones only) N/A 0feet nmeters (Puerto Rico only) d) Attached garage (top of slab) 8.90 ®feet nmeters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building 8.89 0feet nmeters (Puerto Rico only) (Describe type of equipment in Comments) 0 Lowest adjacent (finished) grade (LAG) 9.01 [Z ]feet []meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) 9.10 Qfeet meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. J understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1009. #6437 12 / 12 / 2 0 0 7 fl Check here if comments are provided on back of form. Certifier's Name ROBERT IBA License Number 6437 Title Company Name PROFESSIONAL LAND SURVEYOR NOVA SURVEYORS, INC. Address City State ZIP Code 5582 N.W.'7TH STRE T, 202 MIAMI FL 33126 Signature Date Telephone 12/12/2007 (305) 264 -2660 FEMA Form 81 -31, February 2006 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A 5- 0002903 -5 For insurance company Use: Building Street Address (including Apt., Unit, Suite and/or Bldg. No or .A. uie an x % • • i?olioy'Number 1247 NE 101 ST • • • ••• • • • City • •. State • • • • • • • • ZIP Code Company NAIC Number MIAMI SHORES FL 33138 SECTION D - SURVEYOR, EN2INEER, OIL ARCHITECT CERTIFICATION ( CONTINUED) Copy both sides of this Elevation Certificate for (1) community ial, (2) 114s franc agentEompanj, and (3) building owner. Comments • • • • • ' • ' ' ' • Section C 2(e) lowest elevation thachlnery -is tiie A/C -pad! Crown of Road Elevation = 7.75 Feet • •• • • • • ••• • Signature • • l�atg ; ; ; • • • ; ; • l 12/12/2007 Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grate (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is feet ameters above or nbelowtheHAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is feet ®meters above or below the LAG. E2. For Building Diagrams 6-8 with permanent flood openings provided in Section A Items 8 and/or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is feet nmeters above or [:] below the HAG. E3. Attached garage (top of slab) is feet meters above or below the HAG. E4. Top of platform of machinery and /or equipment servicing the building is feet meters above or below the HAG. E5. For Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? Yes [:]No Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name RICHARD C ALTERMAN Address 1247 NE 101 ST City MIAMI SHORES State FL ZIP Code 33138 Signature Date Telephone i Comments �] Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 and G9. G1. M The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. E] A community official completed Section E for a building located in Zone A (without a FEMA - issued or community4ssued BFE) or Zone AO. G3. [] The following information (Items G4 -G9) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: New Construction Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: feet Flmeters (PR) Datum: G9. BFE or (i n ZONE AO) depth of flooding at the building site: Ofeet ❑meters (PR) Datum: Local Official's Name Title Community Name Telephone Signature - Date Comments Check here if attachments FEMA Form 81 -31, February 2006 Replaces all previous editions