120 NE 100 St (9)UTILi T'(
B A - 1 -4
5 ; t)Rc) M
is *B r--t
1 SocfM �--.3-
IZx8
1 ,•oCFM
r- LORD /Roc >,vM
a
E a 0 C. r_
ac
D1NIN6
tZ x 8
/5bCFM
ioxio
200 crM
LAY'
1_
r r
.50c M
12
12
fbeoRoom
AIR coNorTION(N<a Pt.. /
3 /Iv " - F T
rixa
I�O
OUST ER MUST SIGN THIS BLUEPRINT SIGNIFYING
AaEE»Nr WITH ALL GRILLE LOCATIONS, ACCESS
IDLES, TUBING RUNS AND EQUIPMENT LOCATIONS.
ANY EXISTING CEILING MPS, SOILED CARPETS,
OR WALLS, MUST ALSO BE NOTED ON PRINT AND RE-
1U ED TO INSTALLATION. ALL INS'TRUCTIC 1AL
AND PARTS MANUALS HAVE BEEN GIVEN TO CUSH:VER.
CUSTOMER
CONIRFCIOR
QUAN. MODEL NO.
NOTES
1. Insulate all supply ducts with a vapor barrier fiber-
glass wrap
Vapor seal all laps & joints with asphalt mastic.
2. Line all return air ducts and first 10 ft. of supply
duct with duct liner.
3. ploy turning vanes in all rectangular turns.
4. Secure all condensing units and packages to frames
or pads with metal straps.
5. Run all drains to code. Employ aux. drain pans and
drain from all air handlers.
6. Verify all dimensions and conditions by a'job site
inspection.
7. All equipment is to be checked prior to starting
job and any shortages or wrong equipment immediately
reported. Check refrigerant lines in particular
and do not uncoil if of wrong size or length.
8. Comp all local codes.
9. Exterior duct work is to be lined with 1 " -1 1/2#
fiberglass ductliner impaled top & sides on 15"
lineal centers, water- proofed, and coated white.
10. A screwed on access panel is to be provided for all
evaporator coils.
11. All units are to be placed so that they may be
readily serviced.
12. Closet, including door, is to be acoustically lined
when used as a return air plenum. `
DESCRIPTION. DIMENSIONS & WEIGHT
:4iIG = 1111111lf;�irWl1Z1llitiVaWRAP MAIL
111=17-3L
8KW 8KW NE T -'
CUSTOM AIR CONDITIONING
for
F� 2RE5� l
SEARS, ROEBUCK & CO.