SURVEYSTATE OF FLORIDA) s CO Y OF DARE he desires to build A FF IDA <<IT State of Florida, being duly sworn, doth depose and say: that under the provisions of Section B -368, Sub - section (d), of the B 'lding Code of Miami Shores Village n' Lot Block?? of 2 ��` ; U subdivisi • ; that he is the owner of said property, and will do the work personally, and that he will, at such times as are required by the Zoning and Building Directors d 1. File plans and specifications and obtain approval of Village Planning Board and of the Building Inspector. 2. Apply for and secure a permit. 3i Pay the required fees for license and for permit. 44 Execute the work in accordance with the provisions of the Zoning, Building, and Electrical Codes of Miami Shores Village, 5i Apply for inspections. 6: File with the Building Inspector certificates that provision has been made to carry the necessary Workman's Compensation,. Public Liability and Vroperty Damage Insurance. 7. File with the Building Inspector as the job p4ogresses certificates showing the payment required by the Federal Social Sesurity Act to the State of Florida or the United States of America. 8. Assume the responsibility of not employing contractors or sub - contractors other than those properly licensed by Miami Snores Village or any part or portion of the work including, but not limited to, general contracting, plumbing, heating, electrical, septic tank, solar system, lathing, tile, torrazo, painting, roofing and shoot metal work or installation. 9. Not sot himself up as a "Contractor". 10. Execute Builder's Bond: And further this Deponent says not. lt. of the Village of Miami Shores, County of Dade and 1. Signature of Applicant. 2, Signature of Officer administering oath. SUBSCRIBED AND SWORN TO BEFORE ME THIS DAY of A. D. i 19 2i CERTIFY TO: William Brady Notes: 1. No underground installations or improvements have been located. 2. No instruments of record reflecting easements, right of way, and or ownership were furnished to this surveyor except as shown. 3. Unless otherwise noted record and measured data are in substantial agreement. 4. The Street Right -of -Way abutting this property are physically open unless otherwise noted. 5. Fence ownership, if any, was established by visual means only, but legal ownership has not been determined. 6. Set Iron Pipe or Pin with cap #5443 (18" in length by 0.2 square inches, minimum) at all corners unless otherwise noted. 7. Not valid without the signature and the original raised seal of a Florida licensed surveyor & mapper Legend: A complete list of abbreviations used in this survey are shown on the back of this sheet. Address: 1144 NE. 101 St. Miami Shores, FI. 33138 Legal Description: Lot 3 in Block 177 of " MIAMI SHORES SECTION 8 REVISED " according to the Plat thereof, as recorded in Plat Book 43 at Page 67 of the Public Records of Miami -Dade County, Florida. I hereby certify that the property as shown and described hereon was surveyed under my supervision , also that this survey meets the Minimum Technical Standards set forth by the Florida Board of Professional Surveyors and Mappers in Chapter 61G17-6. Florida Administrative Code, pursuant to Section 472.027, Florida Statutes. And, that the sketch hereon is true and correct to the best of my knowledge and belief. Subject to notes and notations shown hereon. by: Pedro L. Martinez Reg. Surveyor & Mapper #5443 State of Florida Field Survey Date: 11 -17 -2001 #01 -96 PREPARED BY: Pedro L. Martinez 5600 W. 9 Lane. Hialeah, Florida 33012 TEL. (305) 362 -1127 Signature/ Seal Date SHEET 1 OF 2 SHEETS A Arc Length AC Alr Conditioner ADON Addition ALUM Aluminum APPROX Approximate ASPH Asphalt AVE Avenue BC Broward County BL Base Line BLDG Building BLK Block BLVD Boulevard BM Bench Mark BNDY Boundary BOTT Bottom CNE Canal Maintenance Easement C /Calc Calculated CB Catch Basin CD Chord Distance CHB Chord Bearing C/B Concrete Block C&6 Curb 8 Gutter CL Center Line CLF Chain Link Fence CM Concrete Monument CMP Corrugated Metal Pipe CO Cleanout COL Colunm CONC Concrete CONST Construction COORD Coordinate C0R Corner COV Covered CR County Road CS Concrete Slab CT Court CULV Culvert 0 Deed DB Deed Book DC Dade County OCR Dade County Record DEFL Deflect or Deflection DIA Diameter DIST Distance DR • Drive DRA Drainage Retention Area DE Drainage Easement DWG Drawing DWY Driveway E East ENC Encroach ELECT Electrical EL Elevation ENCL Enclosure ESNT Easement EOM Edge _of Water - EXIST ,Ezisting: FCM ; Found' Concrete- Monument FRO Found ' FENA - Federal Emergency Management Agency FIRM 'Net•ional Flood Insurance Program FF Finish Floor FFE Finish Floor Elevation FH Fire Hydrant Legend of Survey / Abbreviations FIP Found Iron Pipe /Pin FL Flowllne FN Found Nall FT Feet or Foot FE Flowage Easement GAR Garage GR Guard Rail 60 Grade GN0 Ground GOVT Goverment GPS Global Positioning System GW Guy Wire HORIZ Horizontal HP High Point HT Height HW Head Wall HWL High Water Line IP Iron Pipe IV Invert LME Lake Maintenance Easement L Length LP Light Pole LT Left MAINT Maintenance MAS Masonry MAX Maximum NH Man Hole M Field Measured MIN Minimum NKR Marker MN Mean MON Monument MSL Mean Sea Level N North NCO Nall 8 Disk NAD 83 North American Datum of 1983 NE Northeast NO Number N. Rad Not Radial NTS Not to Scale NSV0 National Geodetic Vertical Datum NW Northwest NFIP National Flood Insurance Program OHC Overhead Cable ORB Official Record Book P Plat PAR Parcel PAT Patio PAY Pavement P8 Plat Book PC Point of Curvature PCP Permanent Control Point PED Pedestal PG Page PI Point of Intersection PK Parker Kalon Nall PL Property Line PLTR Planter P08 Point of Beginning PP Power Pole PRM Permanent Reference Monument PROJ Project R Record by Plat /Deed RAD Radial /Radius REF Reference RES Residence RET Retention /Retaining RNG RP RR RD R/W S SAN SCM SCN SE SEC SEW SIP SN SP SPEC SO FT or SF SR ST STD STA STM STRUC STY SUB SW SWK T TBM TEL TEMP TOB TOP TR TRANS TWP TYP UE UGD USES UTIL UB V VAR VC VOL w WD WM WMN WT WV Range Radius Point Railroad Road Right -of -Way South Sanitary Set Concrete Monument Screen Southeast Section Sewer Set Iron Pipe /Pin Set Nall Screen Porch Specification Square Foot State Road Street Standard Station Storm Structure Story Subdivision Southwest Sidewalk Tangent Temporary Bench Nark Telephone Temporary Top of Bank Top of Pipe Tract /Trall Transformer Township Typical Utility Easement Underground US Geological Survey Utilities Utilities Box Vertical Varies Vertical Curve Volume West Wood Water Meter Water Main Water Table Water Valve SYMBOLS A Delta Angle 0' Degrees 0' Minutes 0' Seconds Feet When Used In Distance. Inches When Used In Distance i0.0 Existing Elevation x10.0 Proposed Elevation Proposed Surface Flow O Set Iron Pipe or Pln with Cap 45443, unless otherwise shown +/- More or Less x Distance Not Supported by Field Measurement 0 un FIP. 1/2 No I.D. 9.90' 00 9.90' FIP. 1/2 No I.D. LaJ J J in 90' f o Lri (V 0 CV 0 NOT VAUD WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA UCENSED SURVEYOR & MAPPER. t: \( DRAWINGS I \PEDROM \1144NE101ST.OWG 11 -18 -01 1:59:12 pm ES BOUNDARY SURVEY SCALE: 1" = 20' NE. 101st STREET 20' Pavement 75' R/W. 27' PARKWAY 75.00' (M) 1.5' CONC. 20.00' 1 —STORY Res. # 1144 1:31 7' . —CON C /4' u-i CONC. 11LE 12' 35.30' 10' 10' CONC. 00 TILE LEGEND — —Overhead Wire the — — Wood Fence — x _Chain Lick Fence 0 00 r N 4 CONC. 11LE 75.00' (M) `9' PAVEMENT P= Existing Elevations It =Water Meter gai =Catch Bosh •n, =Power Pole FIP. 1/2 193.30'(M) 90' No I.D. 14.90' WALL 9.90' 00 N • 0.20' FIP. 1/2 No I.D. 0.20' 0 r7 X - PL =Planter F.DH. =Found Dral Hole F.N&D. =Found Nail & Disc. FIR. =Found Iron Reber RP. 1/2" No I.D. NE. CORNER LOT 1 Sheet 2 of 2