Loading...
1130 NE 100 St (9)t • PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 8-26. q a J Job Address 1 130 de 100 5t. Tax Folio (! 3 2-05" — O (-f Y O Legal Description Owner/Lessee / Tenant J C, V1(1 03A VOWWSk Owner's Address 113 0 N C 10 o St {e e1L Contracting Co. N I 1 Jl a4 e U i (1 Q oW Qualifier 'David B r'eyi baum State # 0 61C t7 0 L- FEES: PERMIT Signature of owner and/or Condo President Date My Commission Expires: . Upton Com.mission # CC 734749 Expires C BDO 0 NG Co �Z NC. OF A TLAN7 . APPROVED: Zoning Building Mechanical Miami Stiofes Municipal # Competency # Ins. Co. Ave ✓i cc i -(4u i fy Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): UILDING ELECTRICAL PLUMBING MEC CAL ROOFING PAVING FENCE SIGN 7 HANI WORK DESCRIPTION 4 f15i a l l otfi io✓1 0C 5hu to ✓5 Square Ft. Estimated Cost (value) 3000.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR. LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that ,11 work will laws regulating construction and zoning. Furthermore, I authorize the above -named con t' to do • , ork stated. SS# S C.C.F. ) 8 /V r e of Contra • . • Historically Designated: Yes No Master Permit # Phone ( o5y 75( - g 2 L 5 Address 7 Nu) 52 5f ✓eet A37--Q Phone 63o5) 5ia== r Owner - Builder • rt'ir Contracto wner- Builder My Commission Expires: 'Liton ,�3►r.v Maw p cCommissfon # CC 734749 I�I Expires May 30, 2002 � BONDED THRU 4 0F t"" ATLANTIC BONDING CO.. INC. NOTARY BOND Electrical done in compliance with all applicable Date Date r e" Plumbing Engineering may 18 ' 98 11:15 NOTICE OF COMMENCEMENT TAX FOLIO N0. FAX P. 1 /1 - 0L -o/ PERMIT N0. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: MO k o o S+'t.sz$ (V1; o-r ; Sore .S 93R421338 199E AUG 26 12:48 2 Description of improvement re plo men t o f Ge n do co i n5t +; or, o C5ho tler5 S: Owner(s) name and address: Jo hn t73fowSki 113o NE Cjt✓eef 5i1o((5 Interest in property: Name and address of lee simple titleholder: 4. Contractor's name and address: A l I Stake. W; ✓id ows 7‘73 N w 52 5t-(€ e-f 6. Lender's name and address: m� FL 3 ((A 5. Surety:(Payment bond required by owner from contractor, If any) Name and address: Amount of bond S 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7.. Florida Statutes, Name and address: 8. In addition to himself. Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided In Sec- ton 713.13(1 Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a different date is specified) Srpn3ture of Owner Sworn to and subscribed before me this d ` of My Commission Emir %p.ohm s 9I1rvnntar Al i 11k1H1 ZOOZUMW seWldx3 BL 33 # uolsslwwo3% tILti uoidl1 UUJ9w 'd A „4,92.2_,gy 0 : DADE RErY CERTIFY •t o' this is n frp c t, p f the inoifil i this otiicc on 2 rilay of - - PNEc,S my hand and Officlai Seal. ARVEY RUVIN,CLg5K, o ircuit ondCountyCourfs D.C. q 4-0 rs ct flntwnn; L 33) 3-(c1 METRO -DADE .Your application for Product Approval of: .060" Aluminum, 3003 - H14 Alloy, Storm Panel Strutter under Chapter 8 attic Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Applicant, along with Drawing No. 95 -549, Sheets 1 ihru 4 of 4, (for listing , see Section 8 of this Notice of Acceptance) has been recommended for acceptance by the Building Code Compliance office to he used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the South Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. PRODUCT CONTROL NOTICE OF ACCEPTANCE Florida Storm Panels /Stainless Metalworks, 14475 N.W. 26th Avenue Ora Locka FL 33054 Acceptance No.:96- 0304.01 Expires:07 /11/99 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved:07 /11/96 -1- METROPOLITAN DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI. FLORIDA 33130.1563 (305) 375-2901 FAX (305) 375-2908 INTERNET: mdcc0l @shadow.nol PRODUCT CONTROL SECTION (305) 375-2902 FAX (305) 372-6339 taut Rodfiguez Product Control Supervisor ; - Ls anger, Director Building Code Compliance Dept. Metropolitan Dade County Florida Storm Panels. ACCEPTANCE NO.: 96- 0304.01 APPROVED : ' in 1 1 1996 EXPIRES : JUL 1 1 1999 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. DESCRIPTION 1.1 This approves a .060" aluminum, 3003 -1114 alloy , storm panel designed to comply with the South Florida Building Code, 1994 Edition for Dade County, for the locations where the pressure requirements as determined by ASCE 7 -88 "Minimum Design Loads for Buildings and Other • Structures ", do not exceed the Design Pressure Rating values in Section 7 and within the limitations contained in Section 3. 2. MATERIAL CHARACTERISTICS 2.1. The storm panels shall be constructed as indicated on approved drawing No. 95 -549, Sheet 1 of 4, using .060" thick aluminum, alloy 3003 - 1114. 2.2 Panels are rolled formed, have a nominal width of 12 -1/2" and a total full width of 14 -1/2 ", forming 2" deep ribs 2.3 Components shall be aluminum alloys 6063 -T6, "N" headers, "U" header, 1-1/2"x 1-1/2"x 1/8" sill angle and 2" x 5 "x 1/8 ", 2" x 5 "x 1/4" built -out angles. 2.4 Tested specimen: Dimensions: 4 panels 4 panels 4 panels 4 panels 4 panels 52" wide x 101" long overall. 52" wide x 67" long overall. 52" wide x 48" long overall. 52" wide x 101" long overall. 52" wide x 104" long overall. 4 specimens for windload 1 specimen for windload 1 specimen for windload 4 specimens for impact and cyclic load 2 specimens for impact and cyclic load 3. LIMITATIONS 3.1 The design will be dependent on the maximum panel height of 7-2" or 86 ", for wall mount with bottom sill continuous wood or aluminum tube ledger as shown on drawing No. 95 -549, Sheets 2 of4. 3.2 Minimum separation to existing glass to protect shall he 3" with stitch bolts reinforcement as shown on Sheet 1 of 4. 2 -1 /4" with reinforcing bar (Part 16) as shown on Sheet 1 of 4. 3.3 Maximum clearance between top of panel and inside of header shall he 1/4" 3.4 Special Requirement; Reinforcing bar, consisting of one 1" x I" x 16 Ga. Galv. Steel tube (Part 14) attached with 1/4 " -20 x 3 -1/2" long SS bolts with wingnut assemblies spaced 12 -1/2 "" o.c at panel midspan overlaps; or one (1) row of 1/4 " -20 x 1" long SS stitch bolts reinforcement with wingnuts assemblies spaced 12 -1/2" o.c. at panel midspan overlaps. Panel overlap spans less than 33" do not require midspan reinforcement bars and /or stitch bolts. Orla do Blanco, P.E. - Plans Examiner 11 Prc4luct Control Division Florida Storm Panels. Inc, ACCEPTANCE NO.: 96- 0304.01 APPROVED EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1 1 1996 JUL 1 1 1999 4. INSTALLATION 4.1 The panels shall be installed only in the following condition: 4.1.1 Wall Mounts: (A) (CONCRETE /MASONRY): The panels are secured to an 'II' Wall Header (Parts 2 or 3) at the head and attached with 1/4%20 S.S. studs spaced 6-1/4" o.c. to a 1-1/2" x 1-1/2" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to the wall, using the tension anchors as shown on Section A "Wall Mount Section "; or the panels are directly secured to thc wall using approved tension anchors as shown on Sections F "Wall Mount Section (Direct Mount) ", as shown on Drawing No. 95 -549, Sheet 2 of 4 ; or panels attached at the head and sill to a continuous 'F' track (Part 9) with 1/4%20 x 1" S.S. studs spaced 6-1/4" o.c. , the track is then secured to the wall using approved tension anchors as shown on Sections 1 "Wall Mount Detail ", as shown on Drawing No. 95 -549, Sheet 3 of 4 bearing the Dade County Product Control approval stamp. (8) (WOOD FRAMED): The panels are secured to an '1.1' Wall Header (Parts 2 or 3) at the • head and attached with 1/4 " -20 S.S. studs spaced 6 -1/4" o.c. to a 1 -1/2" x 1 -12" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to the wall, using the tension anchors as shown on Section D "Wall Mount Section "; or at the sill , panels are attached to a continuous 2 x 6 PT wood ledger or 1" x 4" x 1/8" or 2" x 4" x 1/8" aluminum tube ledger plate with 1/4" diameter S.S. lag screws spaced 11" o.c. and #14 SMS at midway between lag screws, thc ledger plate is then anchored to the wall with (2) - 1/4" diameter S.S. lag screws spaced 24" o.c. maximum, as shown on Sections E "Wall Mount Section (Bottom)", as shown on Drawing No. 95 -549, Sheet 2 of 4, or panels attached at the head and sill to a continuous 'F' track (Part 9) with 1/4 " -20 x 1" S.S. studs spaced 6 -1/4" o.c. , the track is then secured to the wall using approved tension anchors as shown on Sections 1 "Wall Mount Detail ", as shown on Drawing No. 95 -549, Sheet 3 of 4 bearing the Dade County Product Control approval stamp. 4.1.2 Ceiling/Inside Mounts: (A) (CONCRETE /MASONRY): The panels are secured to an 'U' Header (Part 4) at the head and attached with 1/4%20 S.S.studs spaced 6-1/4" o.c. to a 1-1/2" x 1-1/2" x 1/8" aluminum angle at the sill (Part 7), both the header and sill angle are anchored to thc wall, using approved tension anchors as shown on Section 13 "Ceiling/Inside Mount Section ", Drawing No. 95 -549, Sheet 2 of 4, bearing the Dade County Product Control approval stamp. (8) (WOOD FRAMED): The panels are secured to an 'U' Header (Part 4) at the head and attached with (3) 014 wood S.M.S. wood screws with minimum of 2" penetration or (3) wood brushings with 1" penetration at each rafter or truss thru a 1 "x 5 "x 1/8" continuous channel (Part 11) or I "x 4 "x 1/8" continuous aluminum tube; at the sill the panels arc attached with 1/4" S.S. studs spaced 6 -1/4" o.c. to a 1 -1 /2 "x 1 -1 /2 "x 1/8" aluminum sill angle (Part 7), the sill angle in then anchored with approved tension anchors, as shown on Section G "S it Mount Detail ", Sheet 3 of 4 , Drawing No. 95 -549, bearing the Dade County Product Con ' al stamp. r ando Blanco, P.E. - Plans Examiner 11 Product Control Division Florida Storm Panels. Inc, ACCEPTANCE NO.: 96- 0304.01 . 'JUL 1 1 1996 . ;JUL 1 1 1999 APPROVED EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 4.1.3 Built -Out Condition; (A) (CONCRETE /MASONRY /WOOD FRAMED): The panels are secured to an 'U' Header (Part 4) at the head, which is attached to built -out angles (Parts 5, 5A, 513 or 6), with I/4 " -20 S.S bolts spaced 12" o.c., and a I -1/2 "x I -1/2 "x 1/8" aluminum studded angle (Part 7) at the sill, which is attached to built -out angles (Parts 5, 5A, 5B or 6). with 1/4 " -20 S.S. bolts spaced 12" o.c., both of the built -out angles are then anchored to the wall using approved tension anchors as shown on Section C "Built -Out Mount Section ", Sheet 2 of 4; or Section 1.1 "Alt. Build -Out Mount Section ", Sheet 3 of 4; Drawing No. 95 -549, bearing thc Dade County Product Control approval stamp; or the panels are secured to an 'IT Header (Parts 2 or 3) at thc head, which is attached to built -out channel (Part 10), with 1/4 " -20 S.S bolts spaced 12" o.c., and a 1 -1/2 "x 1 -1/2 "x 1/8" aluminum studded angle (Part 7) at the sill, which is attached to built -out channel (Part 10), with 1/4 " -20 S.S. bolts spaced 12" o.c., both of the built -out channels are then anchored to thc wall using approved tension anchors as shown on Section J "Built -Out Mount Scction", Sheet 4 of 4 , Drawing No. 95 -549, bearing the Dade County Product Control approval stamp. 4.1.4 Storm Panel Interior Fastening; Panel are secured at sill using component angles (Part 5A and 7) as shown on Detail J "Storm Panel Interior Fastening (Isometric) ", Sheet 3 of 4, Drawing No. 95 -549. bearing the Dade County Product Control approval stamp. 4.1.5 Any combination of the above, 4.2 Anchorage of the shutters shall be to concrete, masonry and /or wood framing and shall consist of only the anchors specified on drawing No. 95 -549, Sheets 1 thni 4 of 4. Substitution of anchor type or indicated embedment is unacceptable. 4.3 Fasteners must have their own Notice of Acceptance and must he made of stainless steel or have adequate protection against corrosion, per DIN 50018. Aluminum contacting metals not considered compatible shall be properly protected. 4.4 Permanent set fastener components, embedded anchor bolts, threaded cones or metal shields, not in use, must be protected against corrosion, contamination and damage at all time. 5. IDENTIFICATION 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Dade County Product Control Approved ". 5.2 Also a Warning Not shall be permanently stamped in each panel advising the home owner or tenant that the storm panels will not offer hurricane protection unless all reinforcing bolts are properly installed. Orlando arE P.E. - Plans Examiner 11 Product Control Division TEST TEST LOAD DESIGN LOAD Defection LARGE MISSILE IMPACT TEST SFBC PA 201 -94 (Stitch Bolt Reinforcement) SATISFACTORY CTC -95 -036 Max. 3 " LARGE MISSILE IMPACT TEST SFBC PA 201 -94 (Aluminum Bar Reinforcement) SATISFACTORY CTC-95-036 Max. 2 -1/4" CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 POSITIVE (101" Span) +68.0 PSF CTC -95 -036 +52.3 PSF CTC -95 -036 CYCLIC WIND PRESSURE TEST SFBC PA 203 -94 NEGATIVE (101" Span) -98.8 PSF CTC -95 -036 -76.0 PSF CTC-95-036 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 POSITIVE (101" Span) +75.0 PSF CTC-95-036 +50.0 PSF CTC-95-036 n Design 1.165 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE (101" Span) -93.0 PSF CTC -95 -036 -62.0 PSF CTC -95 -036 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE (67" Span) - 226.03 PSF CTC -95 -036 - 150.68 PSF CTC -95 -036 UNIFORM STATIC AIR PRESSURE TEST SFBC PA 202 -94 NEGATIVE (48" Span) -442.0 PSF CTC -95 -036 - 294.67 PSF CTC-95-036 DESIGN PRESSURE RATING: See "STORM PANEL SCHEDULE "; Table 1, Sheet 4 of 4, Drawing No. 95 -549 Florida Storm Panels. Inc, ACCEPTANCE NO.: 96 -0304.01 6. USE 6.1 Application for building permit shall be accompanied by two copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Completely dimensioned drawing showing size and location, including height above grade, of openings to receive shutters; mean roof height, length and width of building. 6.1.3 Duplicate prints of approved drawings No. 95 -549, Sheets I thru 4 of 4, bearing the approval stamp, Notice of Acceptance number and date by Dade County Product Control Section, clearly marked to show thc components selected for the proposed installation. 6.2 The Building Official shall ensure the adequacy of shutter to meet thc pressure requirement of the opening in which it is to be installed 7. TESTS PERFORMED TESTS: RESULTS: - 2c- APPROVED EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS : l JUl 1 1 1996 : 1 .1111. 1 1 1999 r ando Blanco, P.E. - Plans Examiner II Product Control Division Florida Storm Panels. Inc. ACCEPTANCE NO.: 96- 0304.01 APPROVED : JUL 1 1 1996 EXPIRES :JUL 1 1 1999 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 8. EVIDENCE SUBMITTED 8.1 Tests: 8.1.1 Test report on: Uniform Static Air Pressure Test Impact Tcst Cyclic Wind Load Test prepared by Construction Testing Corporation, Report No. CTC -95 -036, dated November 14, 1995, signed and sealed by Christopher G. Tyson, P.E. 8.2 Drawing: 8.2.1 Drawing No. 95 -549, Florida Storm Panels, Inc. Storm Panel , Sheets 1 thru 4 of 4 prepared by Knezevich & Associates Inc., dated 01/04/96, Revision No. 2, dated 06/06/96, signed and sealed by V.J. Knezevich, P.E. 8.3 Material certification: 8.3.1 Mill Certified Inspection Reports issued by MSC Metals, dated 09/29/95. 8.3.2 Certified Tensile Test Report issued by QC Metallurgical, Inc., QCM Job No. 5KM -2636, dated November 15 „1995, signed and sealed by James Rocse, P.C. 8.4 Calculations: 8.4.1 Comparative analysis and anchor calculations, dated 12/i 8/95, prepared by Knezevich & Associates Inc., signed and sealed by V.J. Knezevich, P.E. Orlando 3lanco, P.E. - Plans Examiner I1 Product Control Division Florida Storm Panels. Inc. ACCEPTANCE NO.: Q6- 0304.Q1 APPROVED JUt 1 1 1996 EXPIRES JUt 1 1 1999 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. . Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and thc following statement: "Dade County Product Control Approval ", or as specifically stated in thc specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with thc code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misufe of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The copies need not be resealed by the engineer. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages 1, 2, 2(a) through 2(d) and this last page 3. Items 10.11 & 12 listed below only apply to QlazdjlrodUctund.d44ri 10. Unless specifically indicated in the Acceptance (approval), this unit is approved as a single unit installation. For multiple installation of this unit, a separate Acceptance for mullions is required from the Product Control Section. 11. The spacing of fasteners at window sills shall be as indicated in Section 4 of this Notice of Acceptance. The spacing of fasteners in all other parts of the frame, shall be as indicated in Section 4 of this Notice of Acceptance, but in no case shall exceed 24" on center. The first fastener shall be located at a maximum of 6" from each corner and mullion or stile. Fastener shall fully penetrate the buck, which shall be the same size as the one tested with the unit. No wood or plastic shields or pins shall be used for anchoring. 12. llardware for all windows and doors shall conform to Security and Forced Entry Prev en n, , apter 36 of the South Florida Building Code. Orl, 9411anco, P.E. - Plans Examiner 11 Product Control Division END OF THIS ACCEPTANCE. - 3 - H 1 ST - 11 24 1 0 ST - 9 ST - 8 (2)- 25 SH \ (3)- 25 SH EXISTING 4' WOODEN POST 74' 74' X X 63' 63' X 108' X 80' SHUTTER FOR EXISTING DOOR. ST - 6 23 CO x 7173 N.V. 52nd St, Mloni, FL 33166 (305) 513 -3388 LEGEND! ST = 20 GA GALVANIZED STORM PANELS X = EXISTING WINDOW OR DOOR 74' X 50 5/8' ST - 1 ST - 2 ST - 15 GROUND FLOOR X EXIST GARAGE DR 19 1/8' X 38 3/8' ST - 3 John ❑strowski 1130 N.E. 100 St. Miami Shores, FL Job #34186, 7/20/98