Loading...
RF07-301Issue Date: 2/26/2007 Owner's Name: AMELITA LATOJA Permit Type: Roof Work Classification: Roof - New Job Address: 1110 101 Street NE Contractor(s) DALEY ROOFING INC Phone (305)754 -9892 Primary Contractor Yes Additional Information Miami Shores Village, FL 33138- Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Expires: 08/25/2007 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Building Department File Copy Applicant Signature Parcel #: Block: Section: Permit Status: APPROVED Permit Number: RF -2 -07 -301 Phone: 1132050340010 Lot: PB: Total Square Feet: 260 Total Valuation: $ 3,000.00 Re. uired Ins s ections Tin Cap Hot Mop Tile In Progress Up Lift Report Final Roof Fees Due CCF Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $1.80 $0.60 $250.00 $3.00 $6.25 $261.65 Invoice Number RF -2 -07 -27635 Total: Amt Due $261.65 28P`[ Amt Paid NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. RE ROOF FLAT AREA AND REPAIR LEAK ON TILE ROOF 20 TILES -,rn'_) F; 6 ? # Passed Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid . until Inspection Date: 03/06/2007 Inspector: Grande, Claudio Owner: LATOJA, AMELITA Job Address: 1110 101 Street NE Project: <NONE> Miami Shores Village, FL 33138- Contractor: DALEY ROOFING INC Building Department Comments Monday, March 5, 2007 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132050340010 Lot: Phone: (305)754 -9892 Page 1 of 2 RE ROOF FLAT AREA AND REPAIR LEAK ON TILE ROOF 20 TILES Infractio Passed Comments TIN CAP SPACEING False Passed �. Inspector Comments ® -o z -®7 Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until 'Inspection Number: INSP- 40514 Permit Number: RF -2-07 -301 Inspection Date: 03/02/2007 Inspector: Rodriguez, Jorge Owner: LATOJA, AMELITA Job Address: 1110 101 Street NE Project: <NONE> Miami Shores Village, FL 33138- Contractor: DALEY ROOFING INC Building Department Comments Thursday, March 1, 2007 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132050340010 Lot: Phone: (305)754 -9892 Page 1 of 2 Permit Number: RF -2 -07 -301 Invoice Number: RF -2 -07 -27635 Applicant: AMELITA LATOJA Company Name: Owner Address: 1110 NE 101 ST MIAMI SHORES, FL 33138. Job Address: 1110 101 Street NE Miami Shores Village, FL 33138- Date Wednesday, February 28, 2007 02/28/2007 Check Receipt Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Payment Type Check Number 6722 Amount $261.65 Change $0.00 Total Payment: $261.65 Page 1 of 1 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 , BUILDING PERMIT APPLICATION' ....�� FBC 2004 B Y: __.�, _Q!�� .... 77 r7 77 tup Permit No. Master Permit No. Permit Type (circle): Building Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder) AM, t-Z, Z 7 l # TpJ Owner's Address 1 M G {\,F ( C i S T City M t fpm ( ,.s R (L S State V Tenant/Lessee Name Job Address (where the work is being done) } C lam, tO Si City Miami Shores Village FOLIO / PARCEL # Is Building Historically Designated YES NO IV Contractor's Company Name ��'; ty i C_ Contractor's Address 13g _ W 0 b1 . S'T Cit ilk (tt4t..i State Qualifier Name ` ! t L ,1 1 Architect/Engineer's Name (if applicable) Value of Work For this Permit $ Sv Type of Work: ❑Addition ❑Alteration ❑New Describe Work: 4) (LCC f- fAit-kn 4) iu i li I a- L fY LL o, 71 i it ii-cc ,E ( Phone #' ' 7S / Zip 3 3 13 g Phone # County Miami -Dade Zip 33 1 3S' State Certificate or Registration No. Certificate of Competency No. Phone # Square / Linear Footage Of Work: Repair/Replace )(U LUI �J - 7"74(r 10% 5 2O Roofing 1/ /& O Phone # 30Z - 191 ` `I a- zip Phone # ❑ Demolition ******** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** F * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** On Submittal Fee $ Permit Fee $ 2 �...,_ CCF $ CO /CC Notary $ Training/Education Fee $ Technology Fee $ Scanning $ Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ 2(0 t • 65 -i 4 'AID See Reverse side —÷ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) ,O Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE; OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature f r • ,V�=� Owner or Agent The foregoing instrument was acknowledged before me this I / t � day of b• , 20 t , by lifa L JO, who is personally known to me or who has roduc d 1 As identification and who did take an oath. NOTARY PU Sign: Print: tAt M Co �� : on E Tre * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: (Revised 02/08/06) "3(z .1 . -1.„6" Contractor II ,^, The foregoing instrument was acknowledged before me this 2 (/ day of r , 20 01; by OW 1. k...1 who is personally known to me or who has produced T as identification and who did take an oath. Signature NOTARY P ' : 14IC: r r,u '., Sign: Print: My Commission Expires: **************************************: F******************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Plans Examiner Engineer Zoning trr-*Cl a Li - - -- ` - SECTIQN 1,524 . . 1 HIGH VE �•J 1TY1iURRICANE ZONES REQ I Efl • N£ NOTIFICATION F I FINQ CONSIRE A ?IONS. : : • ••• ••• • . • 7-- ^� 17 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provi Ow nl v + required roofing permit, and to explain to the owner the cQpteptpf this gecticp..Thv.provSone df;f \ / a 15 the Florida Building Code, Building govem the minimum? ceqtzign4nt$ 8n4 57and4rds of the✓ irdufiy'for roofiti system installations. Additionally, the following items shoul2 bp 4dQre$si3tl oflhe agreement between the owner and the contractor. The owner's initial in the adjacerf bcrx itldic'atel tttattflt3 itta n has been explained. 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) ar for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in e$cordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. _4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. tg/" 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. _6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not ov�'iloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. t. 144 02 1 1 Owner's /Agent's Signature Date Contractor's Signature 1/10 ti- /ors (O1 - 9 2o / Property Address Permit Number Rev: 1 /20/2005, Computer Services, Building Department • • .. • ...... • • . • •••.• • • • • • • .. • • p BLDG DEPT l i — STATa AND GcOUNAN EUU:) AND n :i0tiI_Z .DX 1 High Velocity Hurricane Zone Uniform Roo#'ing permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION Master Permit No. Contractor's Name: . Roof Type ❑ New Roof ❑ Re- Roofing ❑ Recovering • • 000 • • • 000 •. •• • • • •• •• • • • • • • • • • • • • T Z 1 t•t 2 _ t • • • ••• • • • • • • • • • • • Section A (Gerietal lofofmatrori) : ' : : : ••• • •• ••• • Pr•w ns Not • • • • • Jbbfldjes.• • • • •• •• .• • • • • • .•• •• Roof Category J Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Prescriptive BUR -RAS 150 ❑ Other. Page 2 tde Repair ❑ Maintenance 1 Are there Gas Vent Stacks located on the roof? ❑ Yes VI No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area (ft. O Steep Sloped area (ft. 2o Total (ft. 29 Section B (Roof Plan) Page 1 of 1 Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, dearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Corner She (a' x a'): http: / /www.miamidade.gov/ building /roofingpermiting/permit app_section a.HTML 2/19/2007 Roof System Manufacturer. 1 NOA No: 0,16 System Type: rjkcy Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (P1) Field: 5 2 psf (P2) Perimeters: 17, 3 psf (P3) Comers: /3/, 7 psf Maximum Design Pressure, From the Specific NOA System: ." /6 psf Deck type: 5/8" Plywood • These decks require a fastener pull test by an approved test laboratory Other Deck Type: Deck Support Spacing: Slope: O :12 Fire or Vapor Barrier. Ancho: ase Sheet & No. of Ply(s): Anchor/8 e Sheet Fastener/Bonding Material: Insulation Bas yer Size & Thickness: Insulation Base Lay- Fastener/Bonding Material: Insulation Top Layer Size ; Thickness: Insulation Top Layer Fastener. i ding Material: Wood Nailer. Wood Nailer Fastener Type and Spacing: .... • • • .•. • .. • • •••••• • • • • • • • • • • • • • • • • • • ••• • Surfacing: Field: Fastener Type : N/A Alternate Fastener: • • .... .. • .... High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPMTLIIIENT LECTRONWC erLICATION - - - • - - - - - - • • • • • • • • • • • • • • • • • • • Section C (Low Sloped 1toof §ystem) Fill in the specific roof assembly components. if a component is not required, insert not applicable (N /A) in the t'bOx: • • • • • • • • • • • • • •• • • • • • ••• •• Base Sheet(s) & No. of PIy(s): 4 i / ®L Y Baseheet Fastener/Bonding Material: /5 H'in C , //' Zt Ply Sheet(s) &N // o. of PIy(s): /US Ply Sheet Fastener /Bonding Material: , iF Top Ply: UD/ /ice Gf %'A- Top Ply Fastening/Bonding Material: Single Ply membrane: /v // Single Ply Sheet width: 1/2 sheet width: No. of Single Ply 1/2 sheets: Single Ply Membrane Fastening/Bonding Material: Drip /GS Edge Metal Size & Gauge or weight: 3 ) 3, 21.0 (7 I Drip /GS Material Type: % jfkL(/. Drip /GS Hook Strip /Cleat Metal gauge or weight: N/A Parapet Coping Metal Size & Gauge or weight: N/A Coping Material Type: N/A Parapet Hook Strip/Cleat Metal gauge or weight: N/A FASTENER SPACING FOR BASESHEET ATTACHMENT 1. Field: " o/c @ laps & 2. Perimeter: 6 " o/c @ laps & 9 3. Comers: G " o/c @ laps & Y / rows @ rows @ rows @ NUMBER OF FASTENERS PER INSULATION BOARD Perimeter. Comer: Page 1 of 2 http: / /www.miamidade.gov/ blinding /roofingj,ermiting/section c 4 %202.htm 2/19/2007 ■ Page 3a • • ••• • • • ••• • • • • • • • • • • • .. • • • • • • • • ••••••• .... High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT cLEcTRONLC 9Q'LICATION • • • • • . • ... .. Illustrate Components Noted and Details as Applicable: • Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing,Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Basil FtasIfing Cbr Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. .. • • • .. ••• .. • • • • • ... .. • • • Fare:let WA e ' t / 4 Glean Rod Heigat �� Ft. Page 1 of 1 http: / /www.miamidade.gov/ building /roofingj,ermiting/section c_4 2.html 2/19/2007 MIA M I DARE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 • • • • • • • • • • • • •• .• • • • • • • : • • • • • • • . ' ••• • • • •. •• • • • • • • • • • ••• • • • • • • • • • ••• • • • • .. • MIAMI-DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING • • • •148 WEST FLACGLER STREET, SUITE 1603 • • • • • • • • • • : MIAMI, FLORIDA 33130 -1563 • • • • (305) 375 -2901 FAX (305) 375 -2908 •• • • • •• • • • ••• •• • • • • •• • • • ••••••• SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #02-0408.10 and consists of pages 1 through 31. The submitted documentation was reviewed by Frank Zuloaga, RRC. NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23 /03 Page 1 of 32 Membrane Type: APP /SBS Heat Weld • • ••• • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • •• • ••• ..•. •• • Deck Type 1: Wood, Non - insulated • • •• • • • • • • ; ; • • • •.. • • • •. •.. • ••• ••• • • • Deck Description: 19/ or greater plywood or wood plank decks •• • • •• ••• •• System Type E (1): Base sheet mechanically fastened. • • • • • • All General and System Limitations shall apply. .. • • ••• • • • Base sheet: GAFGLAS #80 UltimaTM Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat- We1dim Smooth or RUBEROID SBS Heat -Weld 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4 ®, GAFGLAS Flex PIyT"' 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General limitation #7) GAFGLAS® Ply 4 ®, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFITTE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill -Tec (GAI.TII'L) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 p , See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec (GAFTITE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill -Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure --75 psf, See General limitation #7) Ply Sheet: (Optional except over RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat- We1dTM Smooth or RUBEROID SBS Heat -Weld) One or more plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6® Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs. /sq. or Ruberoid Torch Smooth torch applied according to manufacturer's application instructions. NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 28 of 32 Membrane: • • ••• • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • • 1 • • • • ... One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, Ruberoid® Torch Plus Granule or Ruberoid® Torch FR torch applied : c .ording to manufacturer's application ipsjructipn §. • • • • • • • Or • • • • • • • • • . ••• • • • •• • • • One or more plies of RUBE1 Ol15 ? SBS'Abat- We1diwPLIIS, RUBEROID® SBS Heat- WeldTm PLUS FR, RUBEROID® SBS Heat- WeIdTM 170 FR, RUBEROID® SBS Heat- We1r+, 4143RplpOii SpS 1teat- We1dmi Smooth, RUBEROID® U1traCladrm SBS,artf gustRaiDe SBS i' eat- We1drm 25 applied according to manufacturer's applicalian mstruttibn$.. • • •• Surfacing: (Optional) Install one of the following: 1. Gravel or slag applied at 400 lb. /sq. and 3001b. /sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. GAF Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. or GAF WeatherCoat Emulsion at 3 galJsq. (Torch Smooth applications only) 3. GAF Weathercote® MB- E(Matrix 715 MB Coating), Applied at 1 to 1.5 gal. /sq. 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 1.5 galJsq. Maximum Design Pressure: See Fastening Above NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 29 of 32 • • • • ••• • • •• •• • • • • • • • •.• • • • • • • • • • • • • • ••• WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Pit 6.when used ac a.. mechanic/Ul fastened base or . . . . . . . . anchor sheet. • • • • • • • • • • • • • 2. Minimum 1 /a" Dens Deck or 1 /2 Type X gypsum lfoaxtNN acceptable to be u istatted directly over the wood deck GENERAL LIMITATIONS: • • • • • . •• • • • • • • • • •• • • • •• ••• •• • • • • 1. Fire classification is not part of this acceptanck' refer'to 'i cdrrdnt'A1iptoved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of. ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs.sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 32 of 32 t)7:. o3 / 02 WED 14:52 FAX 9 �!, Underwriters Labo .. 3;3 ® • ... ... • • Lizard States Canary code (r ( P•x'\o 047) ¶09439s • • • • • • • • • • ttplheww.ulcam June 20, 2002 Mr Michael J.Gada GAF Materials Corporation 1 361 Alps Road Wayne, NJ 07470 -3689 Douglas C Miller Errneering Group 1.eader Fire Protection Division CpbrIIVC:E2R §ER,V IC1 S • • •• •• • • • •• •• • • • • • • • • • • • • • IF ••• • • • • • • • • • • • • • ••• • • • • ••• • If any questions arise on the above, please contact the writer. Very truly yours, • • • • •• • • •• • • • • • ••• •• Our Reference: R1106 Dear Mr. Gada: This is in response to our conversation on June 20, 2002. As discussed, the following n u r: Q,y Y; ' em meet!: Ciw -s A cr ;teria per ANSI/LT.790 based on existing fire test data Deck. C- 15/32 Incline 1/2 Insulation (Optional): One or more layers perlite, glass fiber, isocyamrrate, pe lite/isocyanurate composite, perlite/urethane composite, :wood fibertrsocyanurate composite, any combination, any thickness. Base Sheet- One or more layers Type Cs2, Ruberoid 20 or Ruberoid SAS Heat Weld Smooth. Ply Sheet. (Optional). One or more layers Type G1 or G2 Membrane- "Ruberoid SAS Heat Weld 170 FR ", "Ruberoid SRS Heat Weld FR" or "Ruberoid SRS Heat Weld Plus" r A lot-for prtllt om.1lnnor dedicated to ou he safety ♦n: =twitted fitted to quiet/ SP-Mc' PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 7- / - ? Address ///4 t/4 f 5 Tax Folio 11 3 C& Gam (*% Legal Descriptions 4 2 444 Lessee / Tenant l' ` Master Permit #,g2 V Owner's Address ` / /6 /`l C / U / S '7 Phone 75r° 3 g.- Contracting Co. c,i c , �� l Address 1463 NE lag STREET Qualifier . 1Arne - Ls th11Ca ss# - Phone N ) State #C CO1313iunicipal # Competency # Ins.Co. Architect /Engineer Address Bonding Company Address Mortgagor 44)?k e Permit Type(circle one) BUILDING WORK DESCRIPTION2 Ii c Square Ft. [ r • r . y .. Pr i ty... st mp name o .nary - tibli Personally known R Produced I.D.O Type and number of I.D produced: ** * APPROVED: - WARNING TO OWNER: YOU MtJST RECORD A NOTICE OF COMMENCEMENT. AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authoriz-,th above -named contractor to do the work stated. Signature of owner and /or C .�• -- President Sign4t Date: '1- tL Cl . Date:` Condo President 1a,19 * * Address LUMBING MECHANICAL OOFI G PAVING FENCE SIGN Estimated Cost(value) 7-0 - 2n). re of Contractor or Owner- Builder Notary as to Contractor or Omer-Builder My Commi _ _ ion Expires: Wary Public. State of rIortda My Commission Expires May 2U4 1994 Bonded thru WIC)tARD 'nr. Agency * * * * * * * * * ** DID rake an oath, or V4IPAY4g0MTTo :r2>5 RADON 4 C . C . F P. ) t 0JZ1 NOTARY TOTAL DUE . Other 1,_b Fire Zoning Building Irt /X/ Electrical Mechanical Plumbing Engineering PLANNING BOARD AGENDA OF.TJLy / ITEM NO. 2 Name of Owner /Apps i cant4 1 //Ih /Phone No. ,.t-t jr Address of Property, and /or Legal Description / / //D 4/I /Q /.57. Nature of Request AW2O1/, e9 J00T s9, Present Zoning /Z — ;20 Area of Present Building a5W12 4 dF Area i-tb Proposed Addition gz9 (33D 0,400V20) Parking Spaces Provided Parking Spaces Required with Addition Setbacks as per Code /Q 'S /QE Setbacks Provided /O' S'/DE VariancesAMMWOWZoning Change Council Action Required Date of Applicant Notification Council Action ddtiami Jhores9illage F L O R I O A A/O Planning Board Action 4 0 - /J9 i Director of Building and Zoning COMMUNITY NO. PANEL NO. SUFFIX DATE OF1 IRM FIRM ZONE BASE FLOOD ELEV. /25098 0093 f " //- 0.1- 87 if -e e. 0' STREET • %1neo0:w,a SW.67 ,:.o, lel Is LEGAL DESCRIPTION: LOCATOR INDEX BENCHMARK NO. 3250 NE B -26 LEGEND OF C.B.S. C.L.F. CONC. A/C 0/H 4D0 a THIS IS .A BOUNDARY SURVEY ABBREVIATIONS: 2704 SOURCE OF ELEVATION PROVIDED BY DADE COUNTY SURVEY DEPARTMENT, RELATIVE TO MEAN SEA LEVEL, NATIONAL GEODETIC VERTICAL DATUM. ELEVATION 12.04 Ft. BM IS A BRASS BAR IN CONC HANDRAIL BASE AT SOUTHEAST CORNER OF BRIDGE OVER BISCAYNE RIVER CANAL. NE 104 ST ( APPROX) 20'* EAST OF C/L OF BISCAYNE BLVD. Sf Ij THUSLY INDICATES ELEVATIONS BASED ON MEAN SEA LEVEL, NATIONAL GEODETIC VERTICAL DATUM. FLOOD INSURANCE RATE MAP INFORMATION CONCRETE BLOCK STRUCTURE = CHAIN LINK FENCE = CONCRETE = AIR CONDITIONING = OVERHEAD = CENTER LINE NSW c.ONS 'RicrloN Lot A of "WEEKS SUBDIVISION ", according to the Plat thereof, as recorded in Plat Book 71, at Page 91 of the Public Records cif Dsde'Cnunt:V. Florian. ti 0. /9 Onc940i / oo/e /o.4'U; /5' 22 PO ✓emeot L0 ci 020 ; *37,, 5 ALLEY I h0 4,4/ gear - 6 'COOOd IQ° 1 1 1 o./ ' 6' a./ODd on /.4e `4(/ no/ /2;o oe / clec %c /, /0 �POVe/77e/>7' . r . TO 4 SWITCH' /• EX)ST!NG .SCI FE r : z0 "RE-MAIN:. L .- _EXIST Il•4V 1 5 'X 6 '' 2) COIVC SLAB - i � 41 4 "X4 ° X 1/4 T HK. STEELCOLUMAt FLOOR PLAN- r r.• pUsr.& RE SIDE+cE 410 O 2 " X . 8 " JOIST 2'OC. ' ! EXP. BOLTS 3' 0. TIE 1.3E.4 EXIST ING CONC. ELO,:K BU/LDIt w4. • um: amemer. -_ ' - - y - T -Y' - '- t . • WEST EL EVATION • I 36 " X -36 "X 12 " C ONC. FOOTING .7 12" BELOW GRADE_ EXISTING CONC. ELO;,K BUILDING WALL all Na l& geolipar n alle ua, eY TESTING LABORATORIES • ENGINEERS • INSPECTION SERVICES • CHEMISTS • DRILLING • ENVIRONMENTAL SERVICES • Miami, November 5, 1992 James Dentico Contracting Inc. e1110 N.E. 101 St Miami Shores, F1. 33138 Gentlemen: /BY. ALBER 0 RAMIREZ, P.E. FLA. REG. No. 23976 SPECIAL INSPECTOR CERT. No. 488 ALL STATE ENGINEERING AND TESTING CONSULTANTS, INC. CERTIFICATION OF COMPLETED FILL Foundation soil density and bearing capability certification for project: Residence located at i fi110 N.E. 101 street MIAMI SHORES, FLORIDA In acordance with your request, we have supervised general site preparation procedures for the above named project and have performed density tests on the natural ground and on fill mateiral used to raise the site to grade. Site preparation procedures were in general accordance with the specifications accepted by U.S. Department of Housing and Urban Development. Based on our observations, results of borings and density test, it is our professional opinion that all of the above building pads are suitable for the construction of the proposed •structure with foundation proportioned for a design bearing stress of 2500 pounds per square foot without settlement detrimental to the building placed upon it. In my opinion, the settlement will not exceed 0.20 inches. 3745 N.W. 50th STREET / MIAMI, FLORIDA 33142 P.O. BOX 66 / HIALEAH, FLORIDA 33010 / PHONE: (305) 638- 5882 -83 DEPTH ( PT DESCRIPTION OF MATERIALS NUMBER HAMMER Iws ON SAMPLER °N^ HAMMER BLOWS ON CASING 1 from 0' -0" to 1' -6" dark brown sandy silt -1 M v1 .1 u1 .O 00 co O, .-+ M M -1 �? d 'D 1- r 00 Q mixed with wood pieces 2 1' 3.' from -6" to -0' dark brown clay 3 4 from 3' -0' to 3' -6" yellowish silt sand 9 from 3' -6" to 4' -6" light brown medium 5 silica sand 6 from 4' -6" to 10' -0" tan sandy coral rock with fine shells 11 7 8 15 9 6'8' 10 8'10' 18 11 END OF BORING AT 10' -0' 12 13 14 15 16 17 18 19 20 TESTING LABORATORIES • ENGINEERS • INSPECTION SERVICES S • GRILLING 3745 N.W. 50th STREET • MIAMI, FLORIDA 33142 PHONE: (305) 638 - 5882/83 TEST BORING REPORT CLIENT ADDRESS PROJECT ADDRESS LOCATION JAMES DENTICO CONTRACTING INC. 1110 N.E. 101 St., MIAMI SHORES, FL. 33138 Proposed residence 1110 N.E. 101 St., MIAMI SHORES, FL. inside of north footing 5' -0" Water level: below surface 11/5/92 at Date As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. X ORDER No REPORT No 1 No B- 2 HOLE 11./5/92 DATE DRILLER MP & JJ ALBERTO RAMIREZ, P.E. ALL STATE ENGINEERING 6 TESTING CONSULTANTS. INC. 92 -0023 `DEPTH (FT) DESCRIPTION OF MATERIALS SAMPLE NUMBER HAMMER BLOWS MPLERN .N• HAMMER BcAS1i+cN 1 from 0' -0" to 1' -O" backfill tan limerock & 4 5 dark brown silty sand 2 from 1' -0' to 4' -0' backfill dark brown 0'2' 4 4 9 3 silty sand 4 3 4 2'4' 4 4 7 5 from 4' -0' to 5' -0" tan medium sugar sand 6 from 5' -0" to 10' -0" tan sandy coral rock fine 4'6' 4 5 7 7 12 7 with shells 7 8 8 6'8' 8 8 16 9 8 9 10 8'10' 10 10 19 11 END OF BORING AT 10' -0' 12 13 14 15 16 17 18 19 20 CLIENT ADDRESS PROJECT ADDRESS LOCATION Proposed residence inside of south footing 5' -0" Water level' below surface 11/5/92 at pate* TESTING LABORATORIES • ENGINEERS • INSPECTION SERVICES • CHEMISTS • DRILLING 3745 N.W. 501h STREET • MIAMI, FLORIDA 33142 PHONE: (305) 638 - 5882/83 TEST BORING REPORT JAMES DENTICO CONTRACTING INC. 1110 N.E. 101 St., MIAMI SHORES, FL. 33138 1110 N.E. 101 St., MIAMI SHORES, FL. As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. X 92 -0023 ORDER No REPORT No HOLE No B- 2 11 DATE DRILLER MP & JJ ALBERTO RAMIREZ, P.E. ALL STATE ENGINEERING 6 TESTING CONSULTANTS. INC a_h/to ja e4L4. - ep - ' 7 / 11( 1 , .d,�. eitz Ze e v X /0 134 -74.1 C/14 c //r/ DA/ ri SeitQwzr4g. E J = , 1"kt-01-1C-e-sL:11 7& i ertel l /zei , 4 71 12--71-e /'78 " 3 776 /e9s,a-4-/bi wadi r 000 pOd. fist , 7L J 79,T- October 30, 1992 Miami Shores Village Buiilding Department 10050 N.E. 2 Avenue Miami Shores, Florida 33138 Re :footing pads for roof deck addition; Miami Shores Permit # 32919 To whomever it may concern: 1. The calculated unit loading under the pad is Tess than 200 PSF. 2. The concrete slab that was poured on grade under Miami Shores Permit #31461 appears to be in good condition and has no visible cracks or indication that it has settled or seperated from the house. 3. The concrete pads will be increased in size to 4 1/2' X 4 1/2' X 1' inorder to reduce the unit loading even furthur. The ground will then be retamped and the steel replaced. 4. If these extra precautions are still not satisfactory, I will advise Mr. Murphy to have a boring test performed. GENERAL AL o E ECTMAL o MIE.CL- lAIIICA .. o PL..JKI G o 'AOOI , :iNG JL iJ D OO CO COTh C frL Si% erely, James L. Dentico, P.E. For : James Dentico Contracting, Inc. 1C 55 iscayne Boulevard 0 Miami Shores, Florida 33138 0 Te sp cns: 335 -755 -0553