Loading...
33 NW 98 StOwners Name and Address .... 2A;kr e Registered Architect and /or Engineer Name and address of licensed contractot...X rl?. lr._..e ! -: ._ Location and legal description of lot to be built on: Lot Block SS Su ivision. Street and Number where work is to be done. ..3. fttr Jt SS ate work to be doe and p se of building ._. STATE OF FLORIDA, COUNTY OF DADE. ss. Disapproved (Signed) MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build. ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether erein specified or not. A copy of approved plans and specifications must be kept at building during prpgress of the work. / Date..._.. ..... Zi , 19 .. — No . %Date_ and for no other purpose. Remodeling Addition Repairs. ( e No. of Stories To be constructed of Kind of � founc tion Roof Covering Estimated Total cost of improvements $..0r/ �/!/ Amount of Permit $. Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to ............. .. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by hint in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such ultlic notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performe under this pennit, as are licensed by Miami Shores Village. Remarks (Signed).. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him state are e. ) Permit No Date 9 ri ......___._ Read, Sworn to and Subscribed before me. Notary Public, State of Florida Bdlding Inspector My Commission Expires to me well known, PLANNING BOARD DATE Chairman Membcr ...._...._ .................. -- Mcrrrber Member Member ...... _._......_._ ._.._ Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will. be made for making corrections or changes to this application after approval has hem obtained from the Planning hoard. A re fee of 31.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. C•I•v•1•L E•N•G•I•N•E•E•R All Dade General P.O. Box 660551 Miami Springs , Florida Project: Dear Sirs; LG ENGINEERING SERVICES, INC. Consulting Engineers 2020 Northwest 7th Street Miami, Florida 33125 Tel: (305) 649 -6454 Fax: (305) 541 -3298 July 16, 2004 TILE UPLIFT TEST Residential Home 33 Northwest 98 Street Miami Shores, Florida Information provided by client: Permit Number: BP2004 -335 Date Completion: July 12, 2004 Roofing Contractor: All Dade General LG Engineering Services, Inc. Project Number: LG04 -1927 . (Testing Laboratory Certificate #00- 0224.07) In accordance with your request and authorization, a representative of LG Engineering Services, Inc. completed the Roof Tile Uplift Test for the rear addition at the above referenced project. This testing was performed in general with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 30 feet above ground surface. The type of tile used for this project was reported to be Monier Roof Tile. This tile was reported to have been foamed in place. At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile in the perimeter area and one test for every 200 square feet of roof tile in the field area were tested. Initially the entire area of the roof was examine for loose tile. More than 10% of the roof tile located in the field area and more than 20% of the roof tile at the roof perimeter and corner were physically examined. Based on our test results, we conclude that the installation of the roof tile at the above referenced project meets the test requirement outlined in the above mentioned protocol. Attached please find a copy of our test report for your review. LG Engineering Services, Inc. appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; LG Engineering Services, Inc. amad Sonny Salleh, P.E. Project Manager • TILE UPLIFT TEST Residential Home 33 Northwest 98 Street Miami Shores, Florida Test Number Test Load (Ibf) Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass 9 • 35 Pass 10 35 Pass 11. 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Report of TILE UPLIFT TEST for Residential Home 33 Northwest 98 Street Miami Shores , Florida Project Number: LG04 -1927 LG Engineering Services, Inc. — Tile Uplift Test Result -- Project Number: LG04 -1927, Page 1 Test Number Test Load (lbf) Test Status 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LG Engineering Services, Inc. -- Tile Uplift Test Result -- Project Number: LG04 -1927, Page 2 APPPDX, p00F 1t5T LOCAT1ON5 ANI2 12IME;N510N5