Loading...
800 NE 98 St (4)V t — t! PERMIT APPLICATION FOR MUNICIPALITIES OF DAD OUNTY , 4fr r a 7 (4, cry )- �2 (OWNER TO RETAIN COPY) CITY HALL OF MIAMI SHORES. Date 5/21/92 Job Address 800 N.E. 98 ST.M. SHORESTax Folio 113206 -014 -2570 Legal Description 4/1/4- 4749, a Of hth /4 //, /L Neck 73 AfiAAN SNd.PEf Seer Aio. 3,PB /a,tyr.37 Owner / LgsmewcJxR§trmult MARK ULMER Master Permit # Address 800 N.E. 98 STREET, MIAMI SHORES. Phone 758 -4355 33166 Contracting Co. SECURITY WINDOWS Address 5100 N.W. 72 AVE.MIAMI,FLA. Qualifier SEYMOUR GOTHELF SS# Phone 591 -8990 State # CBC 945 4iunicipal � � Competency # Ins .Co Architect /Engineer Address Bonding Company Address__ Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING PENCE SIGt WORK DESCRIPTION a/ignih)S REPLACING 25 CASEMENTS AND 3 DOORS WITH 25 ATW,I P /W, 1 GSD AND 2 ALUM DOORS IN EXISTING OPENINGS, NO STRUCTURAL CHANGES. Square Ft. 464:45 Estimated Cost(value) 6,900.00 • WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DC SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTENI TO OBTAIN. .FINANCING, ONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUI NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, an on the attached addendum (if applicable). I certify that all work will he performed to meet th standards of all laws regulating construction in this jurIarilction. I understand that aeparat permits are required for ELECTRICAL, PLUMBING, SIGNS, POU1,11, HOOFING and MECHANICAL WUNK, OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work wil be done in compliance with all applicable laws regulating construction and zoning. Furthermore, authorize the above -named contractor to do the work stat Signature of owner Date: J1jq Notary as to Owner and /or Condo My Commis - - - - - ; ;a +:rya LINDA HANDSHAW 14 MY COMMISSION 1 CC 177229 _ ' EXPI S: January 90 1996 * * * - Rr, o; Bonded T Notary Mlle I IdmNdlans FEES: PERMIT 23. 60 RADON APPROVED: President Mechanical - -GHFT, -CBE 9 4 5 4 QUALIFIER DL: G -341- 780 -32- of Contra° Notary as to Contractor or Owner- Builder My Commission,Expires:, WARY P L %C STA)k: OF FLORIDA IiIY COI24ISSION EXP JULY 25,1995 * * * * "! LADED THRU*GENERAL *INS. Ur*. ** C.C.P. 1,® NOTARY TOTAL DUE ✓ Z / er- tiTlder Other Electrical Plumbing Engineering SECURITY ALUMINUM WITIDOWS 5100 N.W. 72nd AVENUE • MIAMI, FLORIDA 33166 Natire of (Commencement too e• Inirswasal Io tvilom 11 ninu nancnnu THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, 1.1% Florida Statutes, the following information is provided in the NOTICE OF COMMENCEMENT. 01 800 .8. 98 STREET MIAMI SHORES..".ELORIDA Desaiption of property Ix LN 0% 1106,7014m25.70 Permit Number Folio No. of mprovements.- REPLACING 25 CASEMENTS AND 3 DOORS WITH • c....3(.1dcsaipt• i 25 ATW AND 1 P/W AND 1 GSD AND 2 ALUM DOORS IN EXISTING OPENINGS NO STRUCTURAL CHANGE . • This document was prepared by, SECURITY WINDOWS MARK ULMER 5100 N.W. 72nd AVENUE 800 N.E. 98 STREET AND. MAK .ORIDA33156 A jj,Igim s HORES FLOR I DA mAIN_BEsIamu over interest site of the improvement 1.. Simple Title holder (if other than owner) tt.m. Add .&s . SECURITY ALUMINUM WINDOWS Contr. actor 51OON.W. 72nd AVENUE MIAMI, FLORIDA 33166 Address Sooty (if eny)• .... — —Amount of 6,41 Name of person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by section 713.13('1)(a)7., Florida Statutes,. Nome SECURITYALWENUM WINDOWS 5100 N.W. 72nd AVENUE A4dr.ss -MIANHT-FLORIOA.33166 In addition to himself, Owner designates the following person/ to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutee. SEIRfJAWMJNUM Wingtvg_ 5100 N.W. 72nd AVENUE ........ Achiress . Expiration Date: %me ••■■011••• 11110000110111 MPS 111•■•• PREPARED BY: EUGENE TUERO 5100 N.W. 72 AVENUE MIAMI, FLORIDA 33166 MARK UEMrk. . Wm, Sworn to end aksated Woe* fro tilis 41, DV.PE- N p .— ST OF FLORIDA NY COM SION EXP JULY 27.1995 BONDED THRU GENERAL INS. URN , STATE OF FLORIDA COUNTY OF DADE I NUMMI CERTIFY that this Is a true 01 the original .Upd n this office on day of _ A.D. 19 / WITNE my hand and Official Sal. Cterk Umurt Court rE ;ri■ Date .i /' 3 1-743 4J Job Address "00 A),67. qe. Tax Folio Legal Description Owner / Lessee / Tenant Owner's Address °��'`' ` At ,�: „ WINDOWS �A3m,, S � ' t. � R � Contracting Co. L .� i.. �.. F;.6. ss# - Qualifier f v C0-7--1d -F-"4/F- State # Cam- Municipal # Competency # Ins.Co. Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING EEL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION /- ✓A `► C -1,( -1 719 -L • (A)/1)drtk & 1/( ' / /u OTC /,'Gs, Square Ft. / ,4" WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work state Signature of owner and /or Condo President Date: 57g 9li'3 6C }G Eit/C- 71.1G/2-0 Notary as to Owner and /or My Commission Expires: ** * APPROVED: PERMIT APPLICATION FOR MIAMI SHORES VILLAGE k c, A/ 5 7),v g *J c c Condo President S : A (E OF JUL1 1'J1:; C1:i1E:EA'r_ :is. * * * 1 t Phone Master Permit # Address Phone 57f - 799 4 Estimated Cost(value) / / /57,, 62° S of Contractor = er Date: s od/Z 36�7"N2 7tJ Notary as to Contractor or Owner-Builder My Commission Expires * * FEES: PERMIT V IAo RADON C.C.F. 1 t aQ NOTARY TOTAL DUE 0 ( 0 Fire Zoning Buildin Mechanical Plumbing Engineering ** Other Electrical 77 DADE,OUNTY, FLORIDA METRO�DADE ( hairman /1r ,t S (1,„.n.n, l ie e - (7(n,rman L w e t. 1lembers R„ nrdrl IWnei 1 i i Ge,'i ve Berlin 17i,nn,3 t1. Slott, Lim renee .1 Borsar, I'd Br,/, s Oscar Brennan Jo/m Gilpin( Jorste de l.( I H. Carlton Decker .irnold Goldman Raiford M. Horton Dame! Lews John Lirds,rorr( Stool Lose Joseph llokher. Sr. James Poser lVilliam Riles Armando 11. Rco 11u Unerback 1llie'd ll'er Ruch' ti'i ham Board Consultant John Pisrurmo .Staff Charles Danger Sands l4einreb Gil Diamond PRODUCT CONTROL NOTICE OF ACCEPTANCE Security Aluminum Windows and Doors 5100 N.W. 72 Avenue Miami, F1. 33166. Your application for Product Approval of Series 7000 Awning Window A - C30 under Sections 203 and 204 of the South Florida Building Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by Construction Research Laboratory Report No. 5510A dated July 23. 1991 has been accepted by Product Control under the Specific Conditions set forth on, pages 2 -2a and the Standard Conditions on Page 3 for Glazed Products ACCEPTANCE No.: APPROVED EXPIRES 91- 0827.5 Nov. 18. 1991 July 23. 1995 APPROVED: November 18. 1991 • * *PLEASE NOTE ** -1- y ' 4Le METRO -DADE CENTER BOARD OF RULES AND APPEALS SUITE 1010 111 N W. 1s1 STREET MIAMI, FLORIDA 33128-1974 (305) 375 -2981 (305) 375 -2612 it Diamond, P.E. roduct Control Division Supervisor THIS 1S THE COVERSHEET. SEE ADDITIONA L .EAGES FOR SPECIFIC AND GENERAL CONDITIONS BOARD OF RULES AND APPEALS NOTICE OF ACCEPTANCE This application for Product Approval has been accepted by the Metropolitan Dade County Board of Rules and Appeals to be used in the Incorporated and Unincorporated areas of Dade County under the conditions set forth above. Charles Danger Deputy Secretar Metropolitan Dade County Board of Rules and Appeals Security Aluminum Windows v ACCEPTANCE No.: 91- 0827.5 DESCRIPTION OF UNIT MODEL DESIGNATION Series 7000 Awning Window A -C30 OVERALL SIZE: 4' - 5 1/8" by 8' - 0" high APPROVED : Nov. 18. 1991 EXPIRES : July 23. 1995 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS ASSIGNED ACCEPTANCE MARKINGS AAMA 101 -88 A -C30 Dade County Approval #91- 0827.5 Expires: July 23, 1995 Approved for installation up to 15. ft. above grade. CAUTION: Elevation must be reduced in the coastal construction zone DESCRIPTION: Extruded aluminum framed, mill finish, awning window incorporating six ventilators with nominal 3/16" thick annealed glass. CORNER CONSTRUCTION: Framed -coped and screw assembled with two #8 by 3/4" long plated steel Type A thread forming screws per corner. Ventilator -coped and stake assembled corners. SEALANTS: A urethane sealant is used for the perimeter seals. An acrylic small joint sealant is used for the frame and glazing seals. WEATHERSTPTP: A slide -in, bulb - shaped thermoplastic. HARDWARE: One roto operator operating the six ventilators is located at the bottom of -the right jamb (as viewed from the exterior). The operator attachment screws are 110 by 1/2" long plated steel thread forming screws (three total). -2- Gil Diamond, P.E. Product Control Division Supervisor Security Aluminum Windows FORCED ENTRY ACCEPTANCE No.: 91- 0827.5 APPROVED Nov. 18, 1991 EXPIRES July 23, 1995 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS DRAINAGE: Water collecting in the sill drains out through the space between the bottom ventilator and the sill. The unit shall be in substantial conformance with drawing titled "Awning Type Window Series 7000" revised 7 -16 -91 and stamped by CRL and with the following additions: "The window corners are continuously bedded in sealant which joined with the frame weatherstrip and the perimeter sealant. The frame screw penetrations are all sealed. The roto operator and the operator closure plate is continuously bedded in sealant and the screws are sealed. The sill weatherstrip crimping is sealed at the interior. TESTS: SCREWS AND METHOD OF ATTACHMENT INTERIOR WINDLOAD: 45.0 p.s.f. SILL 3 # 10 x 2" PH CP SMS EXTERIOR WINDLOAD: 45.0 p.s.f. HEADER: 3 # 10 x 2" PH CP SMS WATER RESISTANCE : 10.4 p.s.f. JAMBS : 5 # 10 x 2" PH CP SMS AIR INFILTRATION : 0.05 cfm /sf CRL -5510A -2a- NOTE: Please see Note #11, Page 3 APPROVED FOR ELEVATIONS 'UP TO: 15. feet above existing grade This product must be re- evaluated for structural adequacy when installed within the Coastal Construction Zone in accordance with Chapter 23 Sub - section 2309.2 (b) of the South Florida :uilding Code. it Diamond, P.E. Product Control Division Supervisor