429 NE 99 StTest Location
'Uplift Pull
_ t (P or F)
Test Location
Uplift Pull
est (P or F)
-
Test Location
Uplift Pull
est (P or F)
1
r ��. i
26
0/1.S�i1"
51
G�,:'S'r
2
27
52
3
28
53
4
29
54
5
30
55
6
31
56
7 '•
:.
32
57
•
8
33
58
9
34
59
10
35
60
11
> ,
36
61
12
37
62
13
38
63
,14'
,:'
39
64
•
"1.5
40
65
16
41
" '
66
17
42
67
18
43
68
19
44
69
20
45
70
21
46 •.r
71
22
47
72
23
48
73
24
49
74
:+^
25
••••''*'
50
r
75
7 Du Quesne & Associates, Inc.
Consulting Engineers Environmental • Civil • Structural
Testing Laboratory Buildin Inspection services
ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE
IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE
PROTOCOL PA 106
SITE SPECIFIC INFORMATION
Owner's Name:
Job Address* • 2 - N ' --- • =
Roofing Contractor A i... i r y � pp-c 1 t..1 (.r n n _ r
Type of Tile: rA, l 5 ti - FO.t\ A ' T + , i � .
Date Installed: ' l `/
Approximate Roof Height 14 feet Roof Pitch 3 i (Z
Type of Access to Roof: , ' Scaffolds Ladder Other
Approximate Square Footage of Roof 44 ft 2
Required Testing Force: 35 lbs. Testing Equipment: Chatillion DFIS 100
Date Tested 1 • 0 :
TEST RESULTS
P = PASS, F = FAIL
ti
Permit # 406 fJ
SKETCH OF ROOF IN BACK
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT
QUALITY CONTROL TEST.
Du Quesne, P.E.
ngineer
P. 24513
Du • esne & Associ. -s, Inc.
E.B. License #0005245
Lab Certification #94- 0318.01
7821 S.W. 24th Street • Suite 104 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426
UTR N2 11854
.SKETCH OF ROOF
4771 ggr ( - 900.1a3rc
SHEET NO 9 OF
DATE ;7 • 11
JOB
CALCULATED BY
CHECKED BY
SCALE
DATE
l giMME#REMBM � t%
1111■■ ■ ■ ■ ■ ■ ■ ■ ■:.I / ■■ �WM:aEMME■
■ ■ ■ ■ ■ ■ ■ ■ ■ ■i ■il ■ ■ r7i ■`.'' ■ ■ ■11�!f!�i ■ ■ ■■
■11■w ® ®i■ ■ ■■ ■ ■���■ . ■■s�� ■■ ■1111■■
■ .
■ ■■■■ ■■■■1�I�RMIER ►�� ,■ ccs' ■MILLVEMIN
1111■ ■ ■11■ ■�i��l.. . � p � ��7IN■
■■■■ ■11■■■11■■ ■\\!�\■ ■■mma ��nuom■
■■ ■■■■ic!■ ormi iac:�E ne. \ ■i ■- Ag g AIMI
1111■ ■ ■__ E IM malmialmilammtmom ..■■PUNIOR ■■■■2111■ •■•■■
■■■■�!1 !t
■■■■mt ■ ■■,!\\\ ■._l l ■■■■iea ■ ■11m®■■■■
1111■ ■111 ■1■ «J ■►( 111 ■ ■M■ ■ ■■1 iii ■■■ ■■
■■■■11 ■`11 ■/^ \ \1ii1111`■■ ■!1111111 ■11 ■ ■■
■■■V9!1 `'aINI_MML JM\III ■ ■ ■ ■ ■t�M ■(1 ■ ■11 ■■■
■
■■■M ■■r■■iik7 d■ ■■ T■ ■ ■M■ ■ ■ ■ ■■
IUhiiiI!Ii! it!!:!IHI h IE'lIlIlII
IIiIIJ1
•lL•I 1111 \1111'.71`1111111111 I ■ula■r'7r!m 1■a ■w■■
somimummommwmpqmormamammdm
■ 111■1MIBI; �i ■■�1�11■l PISMIr l■11 NI/1111■■
t ,
- A a MOM' EMI
i!I ■tO11 ■11 ■■ MIMMLI1 ■ ■ ■ /r ■ ■■\\ ■11 ■■
:I I■ ■r ■1IC(Z ma■■ ■■■ ■■1Iw■xm ir7■ \111'1
ail ■�� ■1111■■■ 1111■■ ■11 !r11ir ■ \ ■ ■ ■►�11 ■■
iI■r■■1 mare ciumprio '� 1111
11?)
11,111 11x1
NOTES'
Owner/Lessee / Tenant
Notary as to owner and/or
My Commission Expires:
APPROVED:
Zoning
Mechanical
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 9 -14 -96 Job Address 429 N.E. 99 Street
Francine Holland
Signature of owner and/or Condo President
Building
Date
•
&idea Date
MARYLOU HERNANDEZ
MY COMMISSION # CC 324212
EXPIRES: October 10, 1997
Bonded Thru Notary Public Undeiwrtters
Co
Tax Folio
Legal Description Historically Designated: Yes
Owner's Address 429 N.E. 99 Street Phone 754 -0134
ContractingCoQuality Roofing Contractor, Inc. Address 251 N.W. 99th Street
Qualifier Carlos Arocho SS# Phone_ 751_0.36.2
State# R C D D 5 A A 2 7 Municipal # Competency 11 1 Cu.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL R0� PAVING FENCE SIGN
WORK DESCRIPTION Will tear off old roof off to wood deck, tin cap 301b. ASTM felt
as per building code, mop on with type III asphalt one layer of 901b.
ASTM felt and install valleys and eave drip metal where required.
Install Spanish S White Metro Colorthru Tile mortar set approved.
Square Ft. 4 5 s q. Estimated Cost (value) _. 16 , 0 0 0 .0 0— ______ _---------- .-- ......_:. --
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE "1'O DO SO MAY
RESULT IN YOUR PAYING TWICE FOR I PROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING ,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU NOTICE OF COMM ENCEM ENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (ii' alrhlie;aiit: I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I undcrst;ai,1 that st jnt:;ur
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECIIANICAI.. WORK.
OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done to compliance with all
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
Signature of Contractor or honer- Builder
Notary a. to C
6
FEES: PERMIT / 3 RADON ' C.C.F. NOTARY r—
Master Permit II
My Commission Expires:
tractor or Owner - 4 uild i
Electrical
Plumbing i Engineering
1 105 V-g
Date
t'LOj{ HERNANDEZ
MMISSION # CC 324212
CIPtt l 0: October 10, 1997
Not.tryPutic Undei rtters
3 ®O
IOTA_ D(Jl: _ ._ _ _4,
9 v0
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO.
STATE OF FLORIDA:
COUNTY OF DADE: •
96R497910 1996 OCT 30 09:30
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address: 4 2 9 N .E . 9 9 Street
2. Description of improvement: Install new Tile roof .
3. Owner(s) name and address: Mr . & Mrs . Holland
429 N.E. 99th Street Miami Shores, Florida 33138
Interest in property: Owner
Name and address of fee simple titleholder: N/A
4. Contractor's name and address: QUality Roofing Contractor, Inc.
5. Surety:(Payment bond required by owner from contractor, if any)
Name and address: N/A
Amount of bond $ 00
6. Lender's name and address: N/A
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7., Florida Statutes,
Name and address: N/A
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address: N/A
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Y 4P -rn c Sil l 4_C€
Signature of Owner t
Print Owners Name C-1�. SA 1M b \v < < A N r ")
Sworn to and subscribed before me this l'y of
Public
Print Notary's Name
My Commission Expires:
251 N.W. 99th Street Miami, Florida 33150
Miami Shores, Florida 33138
°.CUN Y Cr :";;.'�F
30
, 199(0 .
Prepared by: Car los Arocho
Quality Roofing Contractor,
Address: 251 N.W. 99th Street
Miami,
Fl nri ria 311 cn
123.01-52 2/93
Job Address: y29 £ 99' S+ Contractor: Qtah g_oaj4 (,j jaAProcess No.
APPENDIX 'E'
METRO -DADE UNIFORM BUILDING PERMIT
SECTION II
MORTAR OR ADHESIVE SET TILE SYSTEMS
1. General
The information provided in this Section is required to confirm
Product Control Approval of the proposed tile system assembly;
confirm compliance with the wind load requirements of Chapter 23
of the South Florida Building Code (SFBC); and confirm compliance
with Sections 3403.5 and 3404 of the South Florida Building Code.
2. Documentation
12301 -158
The following documents are required for submission with the
Uniform Building Permit application:
► Two (2) copies of the proposed tile system assembly's and
associated roofing component's Product Control
Approval(s).
► One (1) copy of the tile system assembly and/or roofing
component(s) manufacturer's published application
instructions and literature.
► All documents attached herein, filled out and completed in
full.
3. Project Information
Check one of the following:
Et/New Construction
Re -Roof
Noje: Mortar or adhesive set tile systems are not acceptable as recover
applications.
Mortar or Adhesive Set Tile Systems
Page -1
Is the deck solid s
thed? (circle `yes' or 'no')
no
Deck Time (check one of the following):
O Nominal '/2' Plywood (for re -roof only)
O Nominal '/ Plywood
LY Wood Plank )X(, "
O Other (fill in)
Roof Pitch (fill in):
2. " : 12"
Note: Mortar or adhesive set tile systems shall not be installed at a pitch
greater than 7%: ":12 ". Mortar or adhesive set tile applied at a
pitch greater than 5 ":12" and -less than or equal to 7 ":12" shall
have the first thrcc courses of tile nailed with not less than one
nail per tile. As an alternate, the first three courses of tile may be
applied in mortar over a single layer of minimum 12 ga. wire
mesh with square openings of not less than 34," which is
mechanically attached to the sheathing with not less than one nail
per 2 ft'.
Circle 'ves' or 'no' for each of the following:
Have you attached two copies of the tile system manufacturer's
Product Control A royal for the proposed tile system?
no
Have you attached a copy of the tile system assembly and/or
roofing component(s) manufacturer's published, application
instructions and o r literature
no
Is the proposed underlayment approved for use with this tile
system assembly?
no
Job Address: q A ) . E / / STr C Contractor:
Project Information (continued):
If the proposed underlaymcnt is self - adhered, have you complied
with the venting requirements of Section 2913.3 (b), (c) and (d) of
the South Florida Building Code?
yes no
Are all related accessories approved for use with this tile system
assembly?
no
Are the proposed edge metal attachment fasteners in compliance
with the requirements of the South Florida Building Code (minimum
12 ga. annular ri r}gs1ank, corrossion reisistant nails)?
no
4. The Tile System Assembly:
The following information is required to confirm compliance with
Subsections 3403.5(a) and (c) and Section 3404 of the South Florida
Building Code.
Tile:
Tile Name: S p gM s L ,5 Ctn.- Tc (
Manufacturer: H of rn Roof
Tile Material:
❑ Clay
IJ/ Concrete
❑ Other:
Product Control Approval Number: 1 y — ) l2 1 . 01
Mortar or Adhesive:
Check one of the following which apply to the proposed tile
securement for use with the proposed tile system assembly:
Mortar or Adhesive Set Tile Systems
Page -2
L2" Mortar: Manufacturer: 7 / • G
Mixing Ratio: 3 5
❑ Adhesive: Type:
Manufacturer:
Tile Fasteners (for first three courses
and is less than or equal to 7 ":12 "):
Check one of the following which
fasteners (for the first three courses)
system assembly:
e, Process No.
❑ Minimum 12 ga. galvanized roofing nail:
Length:
O Other: Type:
Length:
�N /A
"
Underlayment:
if roof pitch exceeds 5 ":12"
apply to the proposed tile
for use with the proposed tile
It
Note: All tiles shall be installed in compliance with the provisions set
forth in the tile system assembly manufacturer's Product Control
Approval and the minimum requirements set forth in Subsections
3403.5(c) and 3404.2 of the South Florida Building Code. Tile
fasteners in the first three courses (if applicible) shall be of
sufficient length to penetrate the sheathing a minimum of 1" or
through the sheathing thickness a minimum of / ", whichever is
less.
The following information is required to confirm compliance with
Section 3403.5(b) of the South Florida Building Code.
0
Job Address: 4 /Z7 N E_ q 9 SJrce f
Underlavment (continuedl: Spacing (per tile system assembly Product Control Approval):
Check all of the following which apply to the proposed underlayment
for use with the proposed tile system assembly: Field: L? " o.c.
Laps: 9 " o.c.
ASTM #30 asphalt saturated felt with:
Manufacturer:
❑ ASTM #15 asphalt saturated felt with:
Manufacturer:
Mineral Surfaced Roll Roofing with: 0 19" overlap
O - 6" overlap
'" overlap
Manufacturer:
❑ Other:
Type:
Manufacturer:
Underlavment Fasteners (if applicablel:
Check one of the following which apply to the proposed
underlayment attachment:
Minimum 12 ga. electro - galvanized roofing nail with
minimum 32 ga. x 1'4" tin cap:
Length: 1 "
Manufacturer.
❑ Other:
Type:
Length:
Manufacturer:
"
Contractor: O / J / f"/ 6,1 ; � j/ , tc .. Process No.
O 19" overlap
O 6" overlap 5. Related Accessories:
lY 4" overlap
O 19" overlap
O 6" overlap
O 4" overlap
Mortar or Adhesive Set Tile Systems
Page -3
Edge Metal (refer to Section 3408.2 of the South Florida Building
Code):
Type: tra 10c, n ; z e
Dimensions: ,2. )( 'D'z
Gauge or Thickness:
Finish:
Note: All edge metal shall be nailed on the flange and nailed or clipped
at the face in compliance with the provisions set forth in Dade
County Protocol PA 111, marked Appendix 'U' in the South
Florida Building Code.
Adhesives (check one of the following):
❑ Cold Adhesive:
Type:
Manufacturer:
Flashing Cement:
Type: /ST/t /) tisel.
Manufacturer: Gtr.rr :c._
Job Address: 429 A. E. 99 ST[�T Contractor: G7ica/ 4y 40( e0 1.
Adhesives (continued): Additional Notes:
Note: Application of adhesives shall be in compliance with the Roofing
Component Product Control Approval and the minimum
requirements set forth in Subsection 3403.5(e)(4)(cc) of the South
Florida Building Code.
Ventilation System (check one or more of the following):
The following information is required to confirm compliance with
Subsection 3401.4(e) of the South Florida Building Code.
❑ Ridge: Type Size
Ef Soffit: Type IQ d2nfi3 Size le)(11:-in' /(
Note: If underlayment is comprised of a self - adhered membrane, both soffit
and ridge ventilation systems are required, unless a base sheet is
applied as an anchor sheet below the self - adhered underlayment.
Note: The Tile System Assembly shall be installed in strict compliance
with the application instructions enumerated in the Product
Control Approval. A permit shall be issued for application of the
specified Tile System Assembly only. Any change to the specified
Tile System Assembly shall require submission of a revised
SECTION II with a copy of SECTION I, noting the permit
number issued.
Mortar or Adhesive Set Tile Systems
Page - 4
Process No.
Job Address: L /02 * t, F_ 9 9 S /r'
Contractor: Qic4 t 6,..4�cJo ( Process No.
Ridge Venting: `� y �
(U�eaNle) N / 1
Dcck:
r»e: 119 on
rhicb,eu: 1 X t.P
Underlayment: A-517k
/ Underlayment l si y ]<�.t�
Fastener
Yis
12"
FILL IN APPLICADLE ROOFING COMPONENTS WIIICII MAKE UI'
TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS
INDICATING ADDITIONAL ROOFING COMPONENTS NOT SHOWN
ON THIS PAGE. ( Where Roofing Componcnt not used in Tile Systcm
Assembly, fill in with "N /A ". )
Head Lap Dimension: 3 "
(mrntnnon Y unless otherwtre specified
In the the system numb? yProduct Control
APPovvell .}
Mortar /Adhesive: 7 / e /
Tile Fastener: r 1 j fi
Tile: SQL :OA A S Cep... - �� — te k-
1- e-i Q pcf
Edge Metal or Gutter
Fastener: or qt/ • r `5
'tic.,)_. rtA 11
Bird Stop: ]
(t / applicable ) pis
Edge Metal
or Gutter. tkA. n •
Existing or Proposed l -
Soffit Venting: 3D V €.-v'
160
DETAIL #1
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page -5
Job Address: 1 /,29 A), F 99 s7
Contractor: anal
Ridge Height Eave Height: Roof Mean Height
a feet 10 feet I I feet
BUILDING INFORMATION #1
Job Site Identification:
Mortar or Adhesive Set Tile Systems
Page - 6
Ground Level
Process No.
Insert Building Ridge Height, Eave Height and Roof Mean Height.
Also insert applicable information pertaining to the building below.
( See ASCE 7 -88 Fact Sheet Attached )
C
Exposure Category:
Classification Catcgory:
At I lurricancc Occanlinc?: Y
Basic Wind Speed at
Building Location 110 mph
Building Condition based on
% of openings:
(See Table 9 ofASCE 7-88)
o N
Job Address: y 2_q to t E_ 99. s-F Contractor:
39
BUILDING • ' • • ` #2: R. I .
. Job Site Identification:
Mortar or Adhesive Sct Tile Systems
Page - 7
Skctch Roof Plan, indicating all dimensions, slopes and any roof top equipment.
Also insert variable labeled " which represents perimeter and comer dimensions
per Chapter 23 of the South Florida Building Code.
(See ASCE 7 -88 Fact Sheet Attached)
3,3'- -
1
an with Perimete and Corner Dimensions
Process No.
Job Address: y29 N E 4 11 ST
The undersigned certifies that the Mortar or Adhesive Set Tile System
Assembly is in compliance with the plans, specifications, and details
submitted by the architect.
STATE OF FLORIDA - COUNTY OF DADE
Before me this day personally appeared ! ,i r /Q,5 Ar t- Jt o
who, being first duly sworn, deposes and says that all information submitted
herein is true and correct.
Sworn to and subscribed before me this '1 th day of
199 .
My commission expires:
` 'Y
Licensed Contractor / Owner
Signature
MARYLOU HERNANDEZ
MY COMMISSION 8 CC 324212
WIRES: October 10, 1997
'•f qf„4 ° Bonded Um Notary Public Undetw hers
No /' ry Public
State of Florida
Contractor: a.01 � `'h 6,171, Process No.
Mortar or Adhesive Set Tile Systems
Page - 8
METRODADE
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Metro Roof Tile, Inc.
11350 N.W. South River Drive
Miami, •FL 33178
Your application for Product Approval of:
Spanish S
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as submitted by:
Redland Technologies, The Center for Applied Enginering, Inc., and Testuvell Craig
Laboratories & Consultants, Inc.
has been recommended for acceptance by the Building Code Compliance office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions
on page 3.
This approval shall not be valid after the expiration date stated below. The Office of Code Compliance
reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for
quality control testing. If this product or material fails to perform in the approved manner, the Code
Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The
applicant shall re- evaluate this product or material should any ammendments to the South Florida Building
Code be enacted affecting this product or material. The Building Code Compliance Office reserves the
the right to revoke this approval, if it is determined by the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code. The expense of
such testing will be incurred by the manufacturer.
Acceptance No.:94- 1017.01
Expires:06 /15/98
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
PRODUCT CONTROL SECTION
(305) 375 -2902
FAX (305) 372 -6339
Rau Ro • lguez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Department and approved by the Building Code Committee to be used in Dade
County, Florida under the conditions set forth above.
Approved: 06 /15/95
s anger,
Director
Building Code Compliance Dept.
Metropolitan Dade County
Applicant:
Metro Roof Tile, Inc.
11501 Northwest 117th Way
Medley, Florida 33178
PRODUCT CONTROL NOTICE OF ACCEPTANCE
ROOFING SYSTEM APPROVAL
Category: Prepared Roofing
Sub - Category: High Profile Tile
Type: Nail - on/Mortar Set/Adhesive Set
Sub -Type: Concrete
System Description
Metro Roof Tile, Inc., located in Medley, Florida, manufacturers clay roof tile for nail -on, mortar
set or adhesive set applications. This Product Control Approval relates to Metro Roof Tile's "Spanish S"
high the profile. Refer to appropriate Product Control' Approvals for other tile profiles.
The Metro Roof Tile "Spanish S" tile profile is available in a variety of colors and has matching
trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for
all profiles and form a part of this Product Control Approval.
The Metro Roof Tile "Spanish S" roof tile has been tested in compliance with the South Florida
Building Code requirements for concrete, nail -on, mortar set or adhesive set tile applications. See the
"Profile Drawing" section in this Approval for the Metro Roof Tile "Spanish S" profile drawing. The
Metro Roof Tile "Spanish S" profile has been tested for both wind characteristics and static uplift
performance, therefore, any consideration for installation shall be done as a 'Moment Based System'.
Data for attachment calculations is noted in Tables 1 through 4 of this Approval.
Contact:
Fernando Arias
Metro Roof Tile, Inc.
1 1501 Northwest 117th Way .
Miami, FL 33178
(305) 558-6712
Product Control No.: 94-1017M1
Approval Date:
JUN 1 5 1995
Expiration Date: JUN 1 5 19 9 U
Raul Rodriguez
Trim Pieces
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT
Test Product
Product • Dimensions Specifications Description
Spanish 'S' Concrete 1= 18" PA 112 High profile, interlocking, one - piece,
Roof Tile w = 1 O% :" 'S' shaped, concrete roof tile equipped
Y2" thick with two nail holes and a single roll.
For nail -on, mortar set and adhesive set
applications.
I = varies
w = varies
varying thickness
PA 112 Accessory trim, clay roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each
tile profile.
3 P//21
Raul Rodriguez
Product Control No.: 94-1017.01
Prod uct
1130 Felt
1/43 Coated Base
Sheet
Mineral Surface Cap
Sheet
Rainproof 11
Ice and Water Shield
Mopping Asphalt
Flashing Cement
TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS
Dimensions
N/A
N/A
N/A
Lenzingtex - ZB 140 59" x 164' roll
Underlayment 22 Ibs/roll
30" x 75' roll
36 "x75'roll
or
60 "x75'roll
36 "x75'roll
N/A
N/A
Test
Specifications
ASTM D 226
type 11
ASTM D 2626
ASTM D 249
PA 104
PA 104
PA 103
ASTM D 312
type III orlV
ASTM D 4586
Raul Rodriguez
Product Control No.: 94- 1017.01
Product
Descriptions
Saturated organic felt
to be used as a nailed
anchor sheet.
Saturated and coated
organic base sheet for
single or double ply
underlayment.
Mineral surfaced
asphalt roll roofing
for use as a top ply in
a double ply
underlayment system.
Single ply, nail -on
underlayment.
Single ply, nail -on
underlayment with 2"
self - adhering top
edge.
Self- adhering
underlayment for use
as a top ply in a two
ply underlayment
system with
Approved 1/30 or 1/43
as the base layer.
Asphalt for bonding a
mineral surface cap to
a mech. attached base
sheet in a double ply
underlayment system.
Cut back, asphalt
based, asbestos free,
fiber reinforced,
trowel grade cement
for repair and flashing
applications.
4 ,,(1)/rzt-c)
Mstnufacturer
generic
generic
generic
Lenzing
Performance, Inc.
with current PCA
Protect -O -Wrap, Inc.
with current PCA
W.R. Grace Co.
with current PCA
generic
generic
Test Product
Product Dimensions Specifications Description Manufacturer
Asphalt Primer N/A ASTM D 41 Cut back, asphalt generic
based coating used to
facilitate bonding of
dissimilar materials.
Roofing Nails
Tin Caps
Wood Battens
Tile Nails
Tile Screws
Roof Tile Adhesive
( "Polypro® AH 160 ")
min. 12 ga. with
3 4" head
min. 32 ga.
min. 1 o.d.
max. 2" o.d.
horizontal
min. 1" x 4" for use
with vertical battens
or
min. 1" x 2" for use
alone
min. 8d x 2W' or
min. 10d x 3"
#8 x 2W' long
0.335" head dia.
0.131" shank dia.
0. 175" screw thread
diameter
PA 114
Appendix E
PA 114
Appendix E
vertical Wood Preservers Salt pressure treated
min. 1" x 4" Institute LP - 2 or decay resistant
lumber battens
PA 114
Appendix E
PA 114
Appendix E
Raul Rodriguez
Product Control No.: 94- 1017.01
Annular ring shank,
hot dipped, electro or
mechanically galv.
roofing nails for use
in underlayment
attachment.
Corrosion resistant
circular disc for use in
underlayment
attachment
Corrosion resistant,
screw, smooth or
annular ring shank
nails.
Corrosion resistant,
coated, coarse thread
wood screws.
generic
generic
generic
generic
generic
Roof Tile Mortar • N/A PA 123 Prepared mortar mix Bermuda Roof
( "TileTiteTM ") designed for mortar Company, Inc.
. set roof tile with current PCA
applications.
N/A See PCA Two component Polyfoam Products,
polyurethane adhesive Inc.
designed for adhesive with current PCA
set roof tile
applications.
Product
Hurricane Clip &
Fasteners
Valley Flashing
Drip Edge
Dimensions
Clips
%," width
min. 0.060" thick
Clip Fasteners
min. 8d x 11/4"
min. 26 ga.
min. 16" width
min. 26 ga.
min. 2" face flange
min. 2" deck flange
Test
Specifications
PA 114
Appendix E
ASTM A 525
PA Ill
6
Raul Rodriguez
Product
Description Manufacturer
Corrosion resistant generic
bronze, aluminum,
stainless steel,
galvanized steel or
plastic attachment
clips for supplemental
tile attachment. Clips
are installed with
corrosion resistant
roofing nails
compatible with the
clip.
Galvanized steel
valley flashing
Product Control No.: 94- 1017.01
Galvanized steel drip
edge
generic
generic
Test Agency
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
Testwell Craig Laboratories
& Consultants, Inc.
TEST REPORTS
Test Identifier
7161 -03
Appendix 111
7161 -03
Appendix 111
25- 7200 =1
94 -084
94 -083
7161 -03
Appendix 11
Report Dated
Aug. 1, 1994
P0647 -01
PO402
Project No. 307025
Test #MDC -78
Lab #EA -25
Tech: G. Suarez
7
Product Control No.: 94 -10 17.01
Test Maine /Report
Static Uplift Testing
PA 102
Static Uplift Testing
PA 102(A)
Static Uplift Testing
PA 102
(Quik -Drive Screws, Battens)
Static Uplift Testing
PA 101
(Mortar Set)
Static Uplift Testing
PA 101
(Adhesive Set)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA 108
(Mortar Set)
Withdrawal Resistance
Testing of screw vs. smooth
shank nails
Wind Driven Rain
PA.100
Physical Properties
PA 1 12
Raul Rodriguez
Date
Dec. 1991
Dec. 1991
Feb. 1995
May 1994
April 1994
Dec. 1991
Aug. 1994
Aug. 1994
Sept. 1993
Oct. 1994
July 1994
SYSTEMS
(CONTINUED)
Deck Type: Wood, Non - insulated
Deck Description: New construction 19 4 2 ' or greater plywood or wood plank.
SYSTEM D: Mortar or Adhesive Set Application
Slope Range: 2 ":12" to 7 ":12"
Note: System D is only acceptable in this slope range.
Underlayment:
Roofing Tile:
Comments:
Product Control No.: 94
Install underlayment system in compliance with Dade County Application
Standard PA 120. (See System Limitation #5.)
Install tile in compliance with Dade County Application Standard PA 120.
(See "Data for Attachment Calculations" included in this Approval.)
1. For re -roof applications, 15 / 32 " plywood is an acceptable substrate.
11
Raul Rodriguez
SYSTEM LIMITATIONS
Product Control No.: 94- 1017.01
1.. The standard minimum roof pitch for Metro Roof Tile's "Spanish S" high profile tile shall comply
with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of
installation.
2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter
larger than that of the preformed holes in the tile.
3. System installation shall be in compliance with the system specifications outlined in this Product
Control Approval. The method of attachment utilized shall provide sufficient attachment resistance
expressed as a moment to meet or exceed the required moment of resistance determined in
compliance with Dade County Protocol PA 115 or PA 127. The Metro Roof Tile "Spanish S" tile
profile has been tested for both wind characteristics and static uplift performance, therefore,
attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a
'Moment Based System'
4. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited
testing agency, in compliance with Dade County Protocol PA 106, shall be performed.
5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed
perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's
published literature.
6 All tiles shall bear the imprint or identifiable narking of the manufacturer's name or logo for
identification in the field.
7. Applications for roofing permits shall include a completed Section 11 of the Uniform Building
Permit, a copy of Metro Roof Tile's current specifications and details, a copy of this Product
Control Approval and a copy of the Product Control Approval of any Roofing Component used in
the proposed tile application. Reference shall be made to appropriate data for the required fire
rating.
8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain
quality control in compliance with the South Florida Building Code and related protocols. Samples
taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'.
9. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South
Florida Building Code.
12
Raul Rodriguez
Table 3: Attachment Resistance Expressed as a Moment - M, (ft -Ibf)
for Nail -On Systems
Tile
Profile
'TILE
APPLICATION
APPROVED
NAILS
APPROVED
SCREWS
APPROVED
FIELD CLIP
WITH:
APPROVED
EAVES CLIP
WITH:
1 nail
2 nails
1 screw
2 screws
1 nail
2 nails
1 nail
2 nails
Metro Roof Tile
Spanish 'S' Tile
Battens
N/A
N/A
N/A
26.80
N/A
N/A
N/A
N/A
Direct Deck
6.20
8.40
28.70
31.80
21.20
25.30
26.90
34.90
Table 2: Restoring Moments due to Gravity - M (ft-Ibf)
Tile
Profile
3 ":12"
or Tess
4 ":12"
5 ":12"
6 ":12"
7 ":12" or
greater
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Metro Roof Tile
Spanish 'S' Tile
6.70
7.10
6.60
7.00
6.46
6.84
6.30
6.67
4.08
N/A
Table 4: Attachment Resistance Expressed as a Moment - M (ft-lbf)
- - for Mortar or Adhesive Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Metro Roof Tile Spanish 'S' Tile
Mortar Set
24.50
Adhesive Set
66.50
DATA FOR ATTACHMENT
CALCULATIONS
13
Product Control No.: 94- 1017.0
Raul Rodriguez
Table 1: Aerodynamic Multiplier - X (ft
Tile
Profile
X (ft
Batten Application
X (ft
Direct Deck Application
Metro Roof Tile Spanish 'S' Tile
0.29
0.31
DATA FOR ATTACHMENT
CALCULATIONS
13
Product Control No.: 94- 1017.0
Raul Rodriguez
Product Control No.: 94- 1017.0I
PROFILE DRAWING
METRO ROOF TILE SPANISH 'S' TILE
Raul Rodriguez
METRO DADE
NOTICE OF ACCIPTANCF: STANDARD CONDITIONS
1. Extensions of Acceptance may be considered after a new application has been filed and the supporting
data, test reports no older than ten (10) years, have been re-evaluated.
All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of
Florida.
2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically
be cause for termination, unless prior approval is granted for revisions or change.
3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds
for re evaluation.
4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes.
5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
6. Product approval drawings, where required for permit applications, shall be provided to the applicant by
the manufacturer or his distributors unless otherwise noted in the Notice of Acceptance. The prints need
not be re scaled by an engineer.
7. Failure to comply with the Standard Conditions shall be cause for termination of the Approval.
This approval supersedes all previous approvals.
15
METROPOLITAN DADE COUNTY, FLORIDA
METRO-DADE FLAGLER BUILDING
DUILDINO CODE COMPLIANCE DEPARTMENT
SUITE 1003
MEMO-DADE HLAGLER UUILDINO
140 WEST FLAGLER STREET
MIAMI, FLORIDA 30100.1503
(305) 375.2001
FAX (305) 375 -2 900
Raul Rodriguez
Product Control Supervisor
MIAMI SHORES VILLAGE, FLA. N?
1 +
JOB s t- � L.
ADDRESS
0
INSPECTION
TIME READY D J v 2 '` •
,j1 a
12805
REMARKS •
INSPECTOR DATE
Application is hereby uinde for the approval of the detailed statement of the plans and specifications herewith submitted for the build -
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address . f r D I- /1/ d ..._ ._ No 'V° ./....... Street —.-..
Registered Architect and /or Engineer
Name and address of licensed contrjtctor ✓f 1 3 / 203 _ 4706 F/ Nc Qo
Location and legal description of lot to be built on:
Lot Block Subdivision
State work to be done and purpose of building (by floors) �1 LLIA
Street and Number where work is to be done 4401 2 Alt
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT.
APPLICATION FOR BUILDING PERMIT
New Building Remodeling
To be constructed of Kind of foundation Roof Covering
Estimated Total cost of improvements $ 0400. C'3 e,
amount of Permit
Zone cubage required Tian Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor....,
All notices with reference to the building and its construction may
/J -t
7 lP
I hereby s
be sent to
mit all the pl s and specification for said buildin
Permit No..
Disapproved Date
(Signed)
Building Inspector
Chairman
Member
Member _....__..._._ . --.—
Council Approved Date
Date..._..._...�.`.3 ��C — • - -... 19..7
•
and for no other purpose.
Repairs No. of Stories A�
Addition
/ o sect
C,::... _Td. . J,..f .:............SY.Nt:,O ! t
Date Read, Sworn to and Subscribed before me.
Notary Public, State of Florida
My Commission Expires r
PLANNING BOARD DATE
Member
Member
Member ._
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval
the Planning hoard.
A re inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice
materials and /or workmanship.
/ O 72 0 S 6u /34 t-t
The tin crsigncd applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer
of labor under theFlorida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this
pennit, as are licensed by Miami Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. j ss
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Disapproved Date
has been obtained fmm
for inspection or faulty
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approyal of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address
Registered Architggt and/or Enginggr, : : ._ ..:
Street and Number where work is to be done
Disapproved __._.____�_ -._. _ Date__
(Signed) t'.�e��' '
Building Inspector
Chairman
Member
Member
Council Approved
NOTE: A charge of $1.00 will be made for
the Planning Board.
A re-inspection fee of 51.00 will be charged
materials and /or workmanship.
MIAMI SHORES VILLAGE
State work to be done and purpose of building (by floors)
Natne and address of licensed contractor
Location and legal description of lot to be built on:
Lot Block Subdiv' on
PLA
Date-r - �._....111.r1=
_... No.- ................ Street___-
x •.U.21221a
�•� and for no other
New Building Remodeling Addition Repairs No. of Stories
To be constructed of Kind of foundation Roof Covering
Estimated Total cost of improvements $ 7�2 z, L.572-1?
Amount of Permit $,.
Zone cubage required _Plan Cubage
Distance to next nearest building _ Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for ins. ction� �•e site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such u •..ntr wo . to be pe 1 d under this
pennit, as are licensed by Miami Shores Village.
Remarks.- •------- •-- _-- _ - - - -- (Signed)
Date 3 _2 ir' ? - - Read, Sworn to and Subscribed before me.
STATE OF FLORIDA,
COUNTY OF DADE. ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
.._____to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him state `a are true
-
Permit No. f '(
Notary Public, State of Florida
My Commission Expires
INC BOARD DATE
Member
Member _.._.._..._ ._._.....__.___.._ _
- •---- • - - -• -- _.._..._ _ Member ...._ ...._ ..._....__..__..._ _.._...._...__..._._ ..__._
Date Disapproved Date
making corrections or changes to this application after approval has been obtained from
when such re- inspection is made necessary by improper notice for inspection or faulty