Loading...
GARAGE DOORPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date i — 3 I - 94 Job Address 3 A 99 Sr m iA Tax Folio Legal Description Historically Designated: Yes Noo t/ / Owner/Lessee / Tenant (Q U 1, Q0 MESA-Allis Master Permit # 3 / �� `7 Owner's Address { O 4 , f . ' A u G d f M /fin/ Phone 3 6-- �' & - Q 5 0 Contracting Co. 6 und g-12 Address Qualifier SS# Phone State # Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION GfiROG E `Dad& Square Ft. Estimated Cost (value) (A v ,AA WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature of owner and/or Condo President Date 2— Notary as to Owner and/or Condo President Date otary as to Contract. . • ... Date My Commission Expires: My on Igsssip.pfxpetBtAl NOTARY SEAL r) f,. ' SAt -anRA M MONTIEL T ' , CCF�,,..e sSSION NUMBER 4 .: CC40126 M r � pN?ISSION EXP. 09,, 171928 , 1 „-- Sc7 FEES: PERMIT 1 / . RADON C.C.F. - ,� NOTARY �- TOTAL DUE S APPROVED: Zoning Building Mechanical Plumbing Signature CQ,ALO for or Owner-Builder Electrical / -3� -9� Date Engineering • �METRODADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Atlas Roll -Lite Door Corp. 10407 Rocket Boulevard Orlando, FL 32824 -8512 Your application for Product Approval of: Model 120 Sectional Steel Door 9' x 7' under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: applicant . For listing see section 6 of this Notice of Acceptance. has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall be valid for a period of three years. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Department may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require retesting of this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The expense of such testing will be incurred by the manufacturer. Acceptance No.:95- 0216.01 Expires:03/30 /98 r Raul Rodriguez Product Control Division Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved: 03/30/95 -1- 200'3Didd METROPOLITAN DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SURE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130-1563 (305) 375.2901 FAX (305) 375-2908 PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372-6339 Director Building Code Compliance Dept. -Metropolitan Dade County d d O D d0011 SHl1 WOd3 OC : Z I 964 I C NHf AtLs Roll -Lite Door Corp. Description; This approves sectional door 9' -0" wide x 7' -1" or 8' -1" high made out of structural quality, coating G -90 galvanized steel per ASTM 446 & 525. The door shall be constructed and reinforced as detailed in the approved drawing #S0020015. Skin 24GA 600'39dd 18GA End Stile Center Stile 20GA End Hinge 14GA -2- Center Hinge 14GA ACCEPTANCE No.: 95- 0216.01 APPROVED : MAR 3 0 1995 EXPIRES CIFI C $ N inri7ontal reinforcement Shape Frequency 20 GA U -Bar MAR 301998 1 T &B Section 2 Center Section 2. This door is approved for a maximum design pressure of +-42psf & -48psf and its use is restricted to this pressure. The door passed the impact & cyclic test, therefore it does not require hurricane protection devices. The door shall meet the burglary security requirement of Section 3603.2(c)2(aa) of the South Florida Building Code. The door operating mechanism (not included in this approval) shall be certified by Underwriters Laboratories or other recognize agency. 3. Installation: The door shall be installed as shown on drawings #S0020015. Wood in contact with concrete or cement shall be treated with an approved preservative as set forth in paragraph 2913.2(a) 1 or shall be of a durable species as defined in subparagraph 2913.2(a)6(aa) of the South Florida Building Code. Installation of 2" x 6" wood jam requires a' /," dia dynabolt sleeve anchor and 1" 0'1 thick washer @a 18" o/c with a minimum embedment of 1' /a' into concrete or grout filled concrete blocks. -- Candido Font, P.E. Plans Examiner Product Control Division � c'0a stiiiH 6d0dd __ 16:21 96, 16 rear Atlas Roll- i_ite Door Corp. ACCEPTANCE No.: 95- 421 § .01 APPROVED MAR 3 0 1995 EXPIRES NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 4. Conditions_of_Use; Application for building permit shall be accompanied by duplicate prints of the approved drawings #S0020015 bearing the approval stamp, Notice of Acceptance number and date by the Dade County Product Control Section along with computations prepared by a qualified Florida Professional engineer or architect verifying the adequacy of the door at each site the shop drawings shall bear the signature of the architect or engineer with the following statement: "The supporting structure has been designed for the forces shown on the approved manufacturer's drawing." Application for building permit for replacement doors shall be accompanied by duplicate prints of the approved drawing #S0020015 bearing the approval stamp, Notice of Acceptance number. Also the Building Official must be satisfied that the propose installation meets the use listed on Section 2 above. 5. Identification: All approved products shall be permanently labeled with the manufacturer's name, city, state and the following statement: "Dade County Product Control Approved." 6. Evidence Submitted: Test Reports D.Alg Dravjng Ref. SLnature ATL 011901 -95 01/21/95 5002001$ J.D. Mitrani, P.E. Calculations Sigtlaturc J.H. Dixon 02/08/95 J.H. Dixon, P.E. swine Number LastRevisiort Signajtre Atlas Roll -Lite S0020015 02/08/95 J.H. Dixon, P.E. -2a- - `Candido Font, P.E. Plans Examiner Product Conirol Division NIM30199a ** ,S00' 39dd 1U101 :k..r. METRODADE NOTICE OF ACCEtTANCE: STANDARD CONDITIONS 1. Extension of Acceptance may be considered after a new application has been filed and the supporting data, test report no older than ten (10) years, have been re- evaluated. All reports of re- testing shalt bear the seal, signature and date of an engineer registered in the State of Florida. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination, unless prior approval is granted for revisions or change. 3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds for re- evaluation. 4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the Notice of Acceptance is displayed, then it shalt be done in its entirety. 6_ A copy of this approval as well as approved drawings and other documents, where it applies, shall be provided to the applicant by the manufacturer of his distributors and shall be available for inspection at the job site at all time. The prints need not be - re- sealed by the engineer. 7. Failure to comply with Standard Conditions shall be cause for termination of Approval. METROPOLITAN DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING COOS COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375-2908 R:1111 Rodriguez Product Control Supervisor SPImIG MIRE t DL. INDIVIDUALLY - CAAR= TO cOUNTD 7WC£ - DOOR LOAD. 18 0. (.04C) ENO SiU= 14 Ct. CALL EEL Rxia FA57D4ED TO ST1LIX W,/(4) C 114 z 3/C SflF TAPRK 9E 1E'.. EilEa 15" 111DE COMat SUPPORT FOR (SY OTHERS) TO 9'-8' WIDE 2.25 -il BAR ELEVATION .. _ .. -. _ SPECIFICATIONS & NOTES . - - -- - - 1. DOOM AND HAR>altARE ti!J. BE Dom; HAMEACiURED. MD OLSLILLS IN STRICT A=Rtula MTH SWIMS AS FTTAAMED BY iHE TUMORAL =WEN OF GARAGE DOOR UANLrrACTURERS. . 2 Ste' ARE "24 CA. (.024") ROIL FORMED SMIXIURAL wart Sim (GRAD` A) W? 1W TH1D 33,000 PSI AND Yi16itiAt CIL'Y. COMM OF 090 PR ASN A-525. 3. V3-01:t 1 S (S71L� ARE AID NED AS FOLLOM - • - A. Be SIM ARE Farm ism sa (6) s=11011. EACH RESSW CE ED HAS A PROE:IU( D0. OF.119' AND A MOW OF 0228". EA^F! WELD HAS AN 'IL181AE MGM CF 352.1 IRS W MAR ARO 352.6 LB S. W Tr7isON. B. INIERIMICE SILES ARE FAMED SR RESISTANCE IFDS PER SECTION -MD AINERED ID FACE M8 N D1 ADHESIVE. - - - - - -_ .. G saw 1 TSHEI LQE AND FOUR END.S1i.3 PER SECTION. T -1' HWi 000RS comma OF 4-2t H 5ECIICRa.: sac (4 O4 As SHIM • 5. 6' -1' HIGH DOORS CQI D OF 5-T9 3/8' i90a SE Ct10AS - uz EMIT (8) U-BAPS TOM 6. THE 2X18 000 .f4Y9 GN OE MGM to A *our FILLED DTs BLOCX VLI. OR CCNOREIE COMM 1111IN 1/r W.. W160N SM. OYFM80 3 SLE_4E ANQ6lRS 4' L0N VW A UM= EMBFDIENT OF i.66: MOMS TO BE SPACED A 16' 0.C. UM • 20 T GL GIL1L rim 1 � " X 1 x .o4r SZ<L SEE NOTE 33 sou gm nom ss CLD NCB CENTER HINGE DETAIL JAMB DETAIL 1 (6)-%; sAR LO•JaIOHS 26 SD' WIND LOADS ON STRUCTURE iss L9./FZ i f Pcsmv_ 11 216L3./FT. NEEGATNE WIND PRESSURE 42 P.S.F. POS. 48 P.S.F. KEG. WIND LOADS APPLIED - =mom; STRUCTURAL ON SUooORT1NQ ELEMENTS SLLtt BE DOWNED mum= Wf A RECS1ED TONAL ENONEBt FOR OW LOADS SHOWN ON THIS DRAW VW 31 ADDRtON TO OTHER LO WO S. • [llllllllllll1UUlll DADE COUNTY CEDE I 3/16 ter CALV. STi , TRACK /FMCS FATTDM10 W00D AID WON (2) it s /1LA.= Cx 1 1/2" WOOD LA 2 C.4 y. STEM TRA�C F tD 1RAmC Mrs WITM 1 1 Srxo moms � Nuts 2" ST=. R0LLEIIs (T LONG STEMS) D4LY. STd i C U -BAR DETAIL 0 0 0 24 01. CALM. STEEL (SEE marE DOOR SELT10N PRIME PAWED as RASH COAT OF POLYMER • PAINT. - - wnt stoneRsnoP HOLDER. SCREws. • DOOR SECTION .103' DER C.451. .4A* RLE TOP FUTURE KM) 70 De SAL MN #14 : 3/4' set- TAF'PINO SHEET MEAL SaLE¢ u F/ISTE?1ED 'TO - MGM. SDLE WITH 2) T 14 SCREWS 14 GA. DALY. DID HDIGE -. ROLLER CARRIER BOL TOO OW S Tom (4 f 14 x 3/4' SELF - ue TAPPD10 SHEET METAL s. .011' THICK WY. BOTTOM MERE BOLTED TO END OF S ssM4 14i3�C- door corporation A MASCO Company 10401 ROQ(P7 BLVD. PHONE - ORLMIDO,FL 32824 (401) 857 -0680 copal: HST. + 12' - 'mem D00 P sun SEE DEAR. ON THIS slim F r 1 t 1/2'z 1 1/2'z 1mR CRY. STE , Al LL EtSITElEO 1D WOOD •IlDs • *v POt - FZAC ` 1 1 • MOOD LIES 3 its 12 Ct NOME RARE Ile; PI MCC 1GLS MM TO - 9i. sl1AE lot?! ID N v TOP WtEW - : WPC IMPACKET -- T 2 ICA f< (.130' _ 2' aux rim. TRACK tiPMED • 1 - PEN FOOT TO PROM A SEDGE CLOSO40 ACTION (.1173" TIC* S0811 IMF FLAG BR�:1G 1H S 8RA.^7CET IS FOR 8' HIGH DOORS ONLY. t * FOR 8' HIGH OPD8NCS 76 CHANGE 1D D187 LOCJ11fONS TRACK DETA1 1;.�` ; AIMED AS COMMA NMI THE - C: t! OR6i0>1 moms CODE CU. ! UA$CE GRACE so IT.AI E 10. 9S o / atlas roll- llte ii l MODEL 120 RESIDENTIAL SECTIONAL DOOR (ENGINEER: J.H. DIXON JR P.E. UC No. FL7788 r 15 HEADROOM 1 DATE /13 /95SHT. DRAWN BY: WC CHECKED BY: CAD NO.. 50020015 DWG •