Loading...
251 NE 98 St (2)MIAMI SHORES VILLAGE ✓ BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address.. / � :..fy., � - No Street Registered Architect and /or Engineer .... Name and address of licensed contractor L 24,`3 t c Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 7 �7 :. :7 .; 1. State work to be done and purpose of building (by floors) and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering / Estimated Total cost of improvements $ Amount of Permit $.... Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Su1plement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. Disapproved a (Signed) .... ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are Permit No 4-7 � 2 Read, Sworn to and Subscribed before me. Date t I7 Dat 1=12- / -1 4 • Building Inspector PLANNING BOARD DATE Member Member Member Date Disapproved Chairman Member Member ....... Council Approved NOTE: A charge of $1.00 will be made for making corrections the Planning Board. A re- inspection fee of $1.00 will be charged materials and /or workmanship. T,_._ , 19 c Notary Public, State of Florida My Commission Expires or changes to this application after approval Date has been obtained from when such re- inspection is made necessary by improper notice for inspection or faulty Owner's Name and Address MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMOT Application is hereby made for the approval of the detailed statement of toe plans and specifications herewith submitted for the build in or other structure herein described. This application Is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plats and specifications must be kept at building during progreu of the work. Registered Architect and /or Engineer ........... . Mt , ,,,. Name and address of licensed contractor c° C? kilt . 1... t (1 4.` g - :_.. — Location and legal description pf Jot be built on: Lot 11 leA46' ' Iv a ?okl IL, Subdivision/ii ' .-g If A . 21 -3-1 I- 6 3 `'. c"J Street and Number where work is to be done f� ? l _. P . _ _ _...._ . State work] be�c one and purpose of buildi�gyby j ra) ._ h� C ° �_ ��` i•� et _ :� .__� 1 and for no other purpose. Ncw Building Remodeling Addition Repairs No. of Stories 1 _ To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements S 936Vf3 ' bb Amount of Permit S. .. Zone cubage required plan Cubage Distance .to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. No...._....... _..._ Street___ The undersigned applicant for this building perinit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida \Vorkrnen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, anti has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. F Remarks — t' Pi - . 6'; !' STATE OF FLORIDA, i COUNTY OF DADE. I ss' Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all farts 4] Ifr therein by him stated are e. Permit No..- ( ,47 Date Read, Sworn to and Subscribed before me. /D Disapproved ........_.._.� .. ate. (Signed) Building Inspector Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Mcmbcr \fcrr,ber Member Member .. .. Member — Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection Ice of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. ' 5 BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Description Address of Building Lot This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be perfcrmed in compliance with any plans drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a t4grough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specification9 and that he assumes responsibility for work done by his agents, servants or employees. / / / Signed t f.) (- l , 'i .�..r BY INSPECTOR , t- In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. ., CONTRACTOR OR BUILDER MIAMI SHORES VILLAGE. FLORIDA PERMIT N? 6943 J r Work to be performed under this Permi Bl. DATE 195 Contractor's License No. 2 Subdi- vision Value of 11 Amount of Project $ 1! Permit $ BY AUTHORITY Date ! 7 - 9 5- Job Address ZJ7 A/6 / 8 '7 Tax Polio Legal Description Owner's Address 7-51 N t / D ST. Phone 126'" 33 Z�, Contracting Co. / A .^ /co :,,C'v✓ Address tor 5/ 1 , _. Qualifier ** * APPROVED: Lessee / Tenant , 4N/A 4 / 7/e- D Not�y as to Own My , ommission Ex. s•: — * * Zoning PERMIT APPLICATION FOR MIAMI SHORES VILLAGE e,/% 2 Phone 6 7 8 Sig atue of Contr or or Other- Builder Date: ' /LI M Notaryr , to C My Codunission Expires. RADON C.C.F. � t/ NOTARY Fire Buildin Mechanical Plumbing Master Permit # 3 go K3 Other der * * ** N,Jf TOTAL DUE Electrical Engineering - "' A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF (FIRST INSPECTION 9R269376 1995 JUL 10 10 :0 c PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: ZS/ Al E 96' S -/ 2. Description of improvement: 3. Owner(s) name and address: i v i �J 7'.'/.o Interest in property: Name and address of fee simple titleholder: 4. Contractor's name and address: ��i� �T � CC/V L P APL ,4' -// A7-3 3 / 2 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Own r upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself, Owner designates the foll g person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: Signature of Owne Print Own s Name 9. Expiration date of this Notice of Comm // e ement: (the expiration date is 1 year from the date of recording unless a different date is specified) // 4- b /7,:t, Sworn to and subscribed before me is 7 day of 12 ( , 19 0 ' Z LEMA ROOR1 EZ Notary Public /A 1,04.01' AL ��� yviw F RIDA Print Notary's Na V 1? `P! � l A� My Commission Expires: STATE 0: FLORIDA, COUNTY 0: DADE ; :;:2E Ct :!?v F,:P ;his i. cr uacooy oi / ^ isf: i ^ u'.cocn ^ ," Cy NOTICE OF COMMENCEMENT Prepared by: 0-' A' SAL Address: /,5`0 f Y/ J( / 3� L' 12301 -52 2/93 q q Job Address: / �/ Contractor: Adhesives (continuedl: Note: Application of adhesives shall be in compliance with the Roofing Component Product Control Approval and the minimum requirements set forth in Subsection 3403.5(e)(4)(cc) of the South Florida Building Code. Ventilation System (check one or more of the following): The following information is required to confirm compliance with Subsection 3401.4(e) of the South Florida Building Code. ❑ Ridge: Type Size Soffit: Type! Size Note: If underlayment is comprised of a self - adhered membrane, both soffit and ridge ventilation systems are required, unless a base sheet is applied as an anchor sheet below the self - adhered underlayment. Note: The Tile System Assembly shall be installed in strict compliance with the application instructions enumerated in the Product Control Approval. A permit shall be issued for application of the specified Tile System Assembly only. Any change to the specified Tile System Assembly shall require submission of a revised SECTION II with a copy of SECTION I, noting the permit number issued. Job Address: Ridge Venting: (Uopp/tab/) in in Deck: ( X Type ThThickness. ' Underlayment: .D i v 7 Undet 1 �. Fastener: i t J 4 - - ` ner: l Mortar or Adhcsivc Set Tile Systems Page - 4 Contractor: 12" DETAIL #1 Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 5 Additional Notes: Process No. Process No. Roof Pitch PILL IN APPLICABLE ROOFING COMPONENTS WIIICII MAKE UP TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS INDICATING ADDITIONAL ROOFING COMPONENTS NOT SHOWN ON THIS PAGE. ( Where Roofing Component not uscd in Tile Systcm Assembly, GII in with "N /A ". ) Head Lap Dimension: 1- " (minimum 2' unless otherwise specified in the file system ossemblyProduct Control � APP 0 " 2 0 1 z 4 • U Mortar /Adhesive: Tile: r .- s N Tile Fastener: ' I41- Existing or Proposed Soffit Venting: 5, Edge Metal or Gutter Fastener: e Bird Stop: (lifapplicable ) Edge Metal„ or Gutte C r. .43-- x 3 Job Address: 7.--s7 /' 915 Height: Eave Height: Roof Mean Height feet / 0. 4 feet / Z. f/feet Insert Building Ridge Height, Eave Height and Roof Mean Height. Also insert applicable information pertaining to the building below. ( See ASCE 7 -88 Fact Sheet Attached ) Exposure Category: Classification Category: At I lurricancc Occanlinc?: Y N Basic Wind Speed at Building Location: I IO mph Building Condition based on Vo of openings: (See Table 9 of ASCE 7-88) Ground Level Job Address: e- A 6 B Underlayment (continued): Spacing (per tile system assembly Product Control Approval): . _ Check all of the following which apply to the proposed underlayment for use with the proposed tile system assembly: Field: f2 " o.c. Laps: ) 6 " o.c. ASTM #30 asphalt saturated felt with: 0 19" overlap O 6" overlap 5. Related Accessories: 4 overlap Manufacturer: ' Edge Metal (refer to Section 3408.2 of the South Florida Building Code): ❑ ASTM #15 asphalt saturated felt with: Manufacturer: ill Mineral Surfaced Roll Roofing with: Manufacturer: ❑ Other: Type: Manufacturer: Check one of the following which apply to the proposed underlayment attachment: Underlayment Fasteners (if applicable): Minimum 12 ga. electro- galvanized roofing nail with minimum 32 ga. x 1' / tin cap: Length: 1 y Manufacturer: c7 ❑ Other: Type: Length: Manufacturer: BUILDING INFORMATION #1 Job Site Identification: O 19" overlap ❑ 6" overlap O 4" overlap ❑ 19" overlap ❑ 6" overlap 4" overlap Contractor: Contractor: Mortar or Adhesive Set Tile Systems Page - 3 «L� ❑ Cold Adhesive: Type: Manufacturer: Flashing Cement: Type: Manufacturer: Process No. Mortar or Adhesive Set Tile Systems Page - 6 Process No. Type: Dimensions: 3)c 3 Gauge or Thickness: ?, 1„ 66- Finish: eos4- t 11 4 rJl� Note: All edge metal shall be nailed on the flange and nailed or clipped at the face in compliance with the provisions set forth in Dade County Protocol PA 111, marked Appendix 'U' in the South Florida Building Code. Adhesives (check one of the following): g.A e (4-- Job Address: �i5 N/6 91.7 Contractor: Project Information (continued): If the proposed undcrlaymcnt is self - adhered, have you complied with the venting requirements of Section 2913.3 (b), (c) and (d) of the South Florida Building Code? yes no Are all related accessories approved for use with this tile system assembly? Tile Material: Clay ❑ Concrete ❑ Other: no Are the proposed edge metal attachment fasteners in compliance with the requirements of the South Florida Building Code (minimum 12 ga. annular hank, corrossion reisistant nails)? no 4. The Tile System Assembly: The following information is required to confirm compliance with Subsections 3403.5(a) and (c) and Section 3404 of the South Florida Building Code. Tile: Tile Name: Manufacturer: \ M15-Q 1) Product Control Approval Number: Mortar or Adhesive: Check one of the following which apply to the proposed tile securement for use with the proposed tile system assembly: Mortar or Adhesive Set Tile Systems Page - 2 Job Address: t C ."6 Contractor: Mortar or Adhesive Set Tile Systems Page - 7 ❑ Mortar: Manufacturer: Mixing Ratio: 20 Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12" and is less than or equal to 7 " :12 "): )6 Adhesive: Type: Manufacturer: BUILDING_ INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Job Site Identification: Process No. Check one of the following which apply to the proposed tile fasteners (for the first three courses) for use with the proposed tile system assembly: Minimum 12 ga. galvanized roofi N/A Length: ❑ Other: Type: Length: ail: Note: All tiles shall be installed in compliance with the provisions set forth in the tile system assembly manufacturer's Product Control Approval and the minimum requirements set forth in Subsections 3403.5(c) and 3404.2 of the South Florida Building Code. Tile fasteners in the first three courses (if applicible) shall be of sufficient length to penetrate the sheathing a minimum of 1" or through the sheathing thickness a minimum of / ", whichever is less. Underlayment: The following information is required to confirm compliance with Section 3403.5(b) of the South Florida Building Code. e. / Z Process No. 0/1 )\‘t Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment. Also insert variable labeled "a" which represents perimeter and corner dimensions per Chapter 23 of the South Florida Building Code. (See ASCE 7 -88 Fact Sheet Attached) Job Address: U7 "' C eS7 Contractor: The undersigned certifies that the Mortar or Adhesive Set Tile System Assembly is in compliance with the plans, specifications, and details submitted by the architect. STATE OF FLORIDA - COUNTY OF DADE Before me this day personally appeared who, being first duly sworn, deposes and says that all information submitted herein is true and correct. Sworn to and subscribed before me this th day of 19 My commission expires: Job Address: 1. General 2. Documentation 123.01.158 857 Licensed Contractor / Owner Signature Notary Public State of Florida APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II MORTAR OR ADHESIVE SET TILE SYSTEMS The information provided in this Section is required to confirm Product Control Approval of the proposed tile system assembly; confirm compliance with the wind load requirements of Chapter 23 of the South Florida Building Code (SFBC); and confirm compliance with Sections 3403.5 and 3404 of the South Florida Building Code. The following documents are required for submission with the Uniform Building Permit application: ► Two () copies of the proposed tile system assembly's and associated roofing component's Product Control Approval(s). ► One (1) copy of the tile system assembly and/or roofing component(s) manufacturer's published application instructions and literature. ► All documents attached herein, filled out and completed in full. 3. Project Information Check one of the following: 0 New Construction T Re -Roof Note: Mortar or adhesive set tile systems are not acceptable as recover applications. Mortar or Adhesive Set Tile Systems Page - 8 Contractor: Mortar or Adhesive Set Tile Systems Page -1 Roof Pitch (fill in): 3 " : 12" Process No. •• .4 Process No. Is the deck solid sh_ thed ?(circle 'yes' or 'no') no Deck Type (check one of the following): O Nominal '/ ,." Plywood (for re -roof only) O Nominal V Plywood 16 ) Wood Plank r r b " Other (fill in) Note: Mortar or adhesive set tile systems shall not be installed at a pitch greater than 7'Y2 ":12 ". Mortar or adhesive set tile applied at a pitch greater than 5 ":12" and less than or equal to 7 ":12" shall have the first three courses of tilt nailed with not less than one nail per tile. As an alternate, the first three courses of tile may be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than '4" which is mechanically attached to the sheathing with not less than one nail per 2 ft'. Circle 'yes' or 'no' for each of the following: Have you attached two copies of the tile system manufacturer's Product Control.val for the proposed tile system? no Have you attached a copy of the tile system assembly and/or roofing component(s) manufacturer's published, application instructions and; literature no Is the proposed underlayment approved for use with this tile system assembly? no • Altusa Tile Alfareria del Turbio, S.A. Barquisimeto, Venezuela. Your application for Product Approval' of Attiisa Tile. Nail- On,.Mort .[9 Adhesive Set Clay "A.Ittrsaa S , jt4Qfi..ng Tiles under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by Redland Technologies, The Center for Applied Eugijuecring, Inc., and Testwell Craig Laboratories & Consultant., Inc. has been recommended for acceptance by the Building Code Cotpliance Department to be used in Dade County, Florida under the specific and standard set forth herein. The approval shall be valid for a period of three years. the Building Code Compliance Department reserves the right to secure a product or material .at any time for a .jobsite or manufacturer plant for quality control testing. If. product or material fail to perform in the approved manner, the Code Compliance Department may revoko, modify or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require testing of this product or Material should any amendments to the South Florida Building Code be enacted affecting this product or material. The expense of such testing will be incurred ray the Manufacturer. PRODUCT NO.: Q ,. • / ..._.. _ .. ACCEPTANCE NO.: 9d- 09144)1 Raul Rodriguez EXPIRES: FEB ). g 1997 Product Control Division Supervisor This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. APPROVED: PRODUCT. _CONTROL TNS2. C.0 .AIYCt; PLEASE NOTE - TH1S IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERA) CONDITIONS. l3Ulll)ING CODE COMMITTEE FEB ? iI95 METROPOLITAN DADE COUNTY, FLORIDA METRO-DADE H_AGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SU11E 1003 memo-DADS FLAOLER. 140 WEST FLAMER STREET MIAMI, FLORIDA 331304563 (305) 375.2801 FAX (305) 375.2008 Charles Danger, P.E., si) rector ~r Building Code Compliance Department Metropolitan fade County r • 03/23/95 11:35 V305 887 3283 ' MED'ROOF TILES PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOI'INC SYSTEM APPROVAL Applicant: Altusa Tile Alfareria del Turbio, S.A. Barquisimeto, Venezuela Approval Date: Expiration Date: Category,: Prepared!RAafing Sub- Category: Tile ; Typo: Nail- on/Mortar Set /Adhesive Set Sub -Type: Clay Contact: . .'Carlos J. Fernandez General Manager AltusjT.ile Almar (USA), Inc. - 6645 Northwest 77th Avenue Miami, FL 33166 (305) 471 -5830 1 Product Control No.: 94- 414,¢1 FEB 2 2 1g5; FEB 1 4 1997 4AUILDUCE41.110,R Alfareria del Turbi.o,. S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clayroof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval ralatcs_to_Altusa's IAlsoa S" Refs to appropriate Prod pct .onXrol Approv 1s forotlter rile p * The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also available. Altusa roof tiles have ;been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adheswe set tile applications. The minimum roof slope for the "Altusa S" nail - on tiles shall be 3 ":12" Sec the "Profile Drawing" section in this; approval for the "Altusa S" profile drawing. The '.'Altusa S" profile has been tested for both wind characteristics and static uplift perforrnance,'therefore; any consideration for installation shall be done as a 'Moment Based System':, Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Almar (USA), Inc., lncalecd.,i.n Mimi Florida, is the sole approved importer tinder contract for selling and distributing Altusa products in 'the South Florida jurisdiction. l� 002 •03/27/95 12:02 '8`305 887 3283 Trim Pieces TRADE NAMES OF PItoDUCTs MANUFACTURED OR LABELED BY APPLICANT I— varies w _ varies Varying thickness MED ROOF TILES Q1001 ASTM C 1167 Product Control No.: 94- 0914,01 Test Product Product Dimensions :fRccifirAti4.tii Ucsc_ripti.4n Altusa 'S' Clay Roof 1 = 18 "," ASTM C 1 167 High profile, interlocking, one- piece, Tile w ;*. 10" 'S' shaped, clay roof tile equipped with thick two nail holes and a single roll. For direct deck nail -on applications only. Accessory trim. clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each • tile profile. • 03/23/95 11:37 '8`305 887 3283 MED'ROOF TILES 430 Felt 1043 Coated Base Sheet Mineral Surface Cap Sheet N/A NIA N/A Lenzingtex -7B 140.. 59" x 164' roll Underlayment 22 lbs/roll Rainproof 11 30" x 75' roll 36" x 75' roll or 60" x 75' roll Ice and Water Shield 36" .x 75' roll Mopping Asphalt NIA Flashing Cement N /A, TRADE NAMES OF PRODUCTS MANUFACTURED OTHERS Test bee if calif ASTM D 226 type II ASTM 0 2626 ASTM U 249 PA 104 PA 104 PA 103 ASTM D 312 type 111 or IV ASTM D 4586 Product Control No.: 9z1-09,14.91, Product Description Saturated organic felt to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underl.aym.ent system.. Single ply, nail -on underlayment. Single ply, nail -on underlayment with 2" self - adhering top edge. Self - adhering underlayment for use as a top ply in a two ply underlayment system with approved 430 or 443 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced. trowel grade cement for repair and flashing applications. • pr otect -O -Wrap, Inc. PCA #94 0714.01 Manufacturer generic generic generic Lenzing Performance, Inc. PCA #94-0527.051 . W.R. Grace Co: PCA 492-1(16.01 generic. ;en Z004 03/23/95 11:38 '8`305 887 3283 Product Asphalt Primer • Roofing Nails Tin Caps Wood Battens Tile Nails Tile Screws Roof Tile Mortar ( "TileTiterM ") Roof Tile Adhesive ( "Polyprog A1-1160") 01l01 N/A • thin. 12 ga. with • '4" head • min. 32 ga. min. 1 o.d, max. 2" o.d, xrtiol min. I" a 4" bOtizontal vf1iil- *" Tt 4" . for -U."se with batietjs 'or mitt. 1" x 2" for use alone ntin. Sd x 2V2" or thin. 10d x "s" rnin.-#8 r 2!•1" or min. #10x2" N/A NIA MED__ROOF TILES Test ugcificalions ASTM D 41 PA 114 Appendix E PA 114 Appendix E Wood Preservers Institute 1_P - 2 PA 114 Appendix E PA 114 Appendix E PA 123 Sec PCA 4 Product Control No.: 94- 0914.01 Product Uesc lion Cut back, asphalt based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped, electro or mechanically gals. rooting nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlavment attachment Salt pressure treated or decay resistant lumber battens Corrosion resistant, screw, smooth or annular ring shank nails. Corrosion resistant, coated, coarse thread wood screws. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof the applications. Mitttuf(cturer generic generic generic generic generic generic Bermuda Roof' • Company, Inc. PCA #94- 0614.OI Polyfoam Products, Inc: PCA 494- 0401.61 005 • ,03'23/95 11:39 '$305 887 3283 MED ROOF TILES Product Hurricane Clip & Fasteners Valley Flashing Drip Edge Pimensjgds Clips min.'' 'A" width min. 0.060" thick Clip Fasteners . min. 8d x min: 26 ga. min. 16" width m in. 26 go. min. 2" far: 11ange min. T' dcck'f ange Test p;cifications PA 114 Appendix E ASTM A 525 PA 111 R iii 12nriri0n17 Product Control No.: 94- 0914.01. Product Description Corrosion resistant bronze, aluminum, stainless steel, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. A hurricane clip is required on all cave tiles. Galvanized steel valley (lashing Galvanized steel drip edve Mu generic generic generic 006 SO. ■ 03/23/95 11:40 $305 887 3283 Test Agena Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center. for Applied Engineering, Inca The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. • Testweil Craig Laboratories & Consultants. Inc. TEST REPORTS 7161 -03 . Appendix II1 7161 -03 Appendix [11 25- 7200 -1 94.084 94-083 7161 -03 Appendix ll Leiter Dated Aug 1, 1994 P0647 -01 PO402 Project No. 307025 Test ttMDC -78 Lab ttAAP -2 , Tech: Porcelio MED'ROOF TILES 6 Product Control•No.: • 4- 0914.01 Test Najuc/R4Tsm! Static Uplift Testing PA 102 Static Uplift Testing PA 102(A) Static Uplift Testing PA 102 (Quik -Drive Screws, Battens) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. sr. - th shank nails Wind Driven Rain PA 100 Date Dec. 1991 Dec. 1991 Feb. 1995 May 1994 April 1994 Dec. 1991 Aug. 1994 Aug. 1994 .Sept. 1993 Oct: 1994 Physical Propertit— Oct. 1994 ASTM C 1167 L 007 03/23/95 11:45 Deck Type: Deck Description: SYSTEM D: Slope Range: Underlayment: Roofing Tile: Comments: "&'305 887 3283 _ _ MED ROOF TILES SYSTEMS (CONTINUED) Wood, Non - insulated New construction 19 ,' 32 " of greater plywood or wood plank. Mortar or Adhesive Set Application 2'':12'' 7" Note: System D is only acceptable in this slope range. Product Control No.: 94 0914.01 Install choice of approved underlayment system, noted on Page 1 of Dakle' County Protocol PA 120, in compliance with Section 3.02 of PA 120. See System Limitation #7. Install tile in compliance with PA 120 using one of the approved mortars . or adhesives noted in this approval. Mortar or adhesive shall be applied in • compliance with the mortar or adhesive manufacturer's Rooting Component Product Control Approval. The mortar or adhesive attachment shall-pr cvvide- - sufficient attachment: resistance expressed as a moment to Beet or exceed the required moment of resistance determined in compliance with PA 115 or OA 127. The mortar and adhesive attachment data is noted in Table 4, attached. 1. For re -roof applications, 15 / 32. " plywood is an acceptable substrate. 2. For. set applications, the first three courses of tile shall be nailed. not less than one nail per tile. As an alternate, the first three courses of the shall -be- applied in mortar over a single layer of minimum -12 ga. wire h...- with square openings of not less than 'I ' which is mechanically - �mes lly attached to the deck With, not less than one roofing nail every 1 ff. For ;roof pitches front' 6 ":12" to 77 :1,2 ", every third tile of every fifth course, beginning at the eighth course,: shall be nailed with not less than one nail per tile. 10 • • 03.•123/95 11:46 T2305 887 3283 MEI) ROOF TILES SYSTEM LiMiETATIONS Product Control No.: 99- 0214.01 V/j 012 1. The standard minimum roof pitch for "Altusa S ", nail -on, mortar or adhesive set tile applications is 2" rise in 12" run (2":12").. "the maximum roof pitch for mortar or adhesive set tile applications is 7" rise in 12" run (7 ":12 "): 2. All nail -on tile applications having a roof pitch Tess than 4 ":12" shall be installed over both vertical and horizontal battens ( "Counter-Battens "), as noted in System A. All nail -on tile applications having a roof pitch in excess of 7": 12" shall be installed over horizontal battens as noted in System C. 3. For nail -on applications, brass or stainless steel screws for mechanical attachment of tiles shall have a head diameter larger than tltat the preformed holes in the tile. 4. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. Nail - nn` tile shall be attached using one of the methods of attachment noted in Table 3 of this Approval. Mortar or adhesive set tile shalt be attached using an approved mortar or adhesive noted in this Approval. the data of which is noted in Table 4 of this Approval. The method of attachment utilized .shall pro ide sufficient attachment resistance expressed as a moment • to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115' or PA .127 5. For nail -on tile applications, an'eave clip is required on all cave tile. For mortar set applications, the first three. courses of tile shat{ he nailed with not less than one nail per tile. As an alternate, the first three courses of tile shall he applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3 / which is mechanically attached to the deck with not less • than one roofing nail every "1 0.=. • For roof pitches from 6 ":12" to 7 ":12 ", every third tile of every fifth course, beginning at the eighth course. shall be nailed with not less than one nail per tile. 6. For mortar or adhesive set rile applications, a field static uplift test by a Dade County accredited •testing agency, in compliance with Dade County Protocol PA 106, shall be required not less than 30• days after application to confirm tile adhesion. The results of this testing shall he reported to the I3uilding Official and the installer stating that the application has passed or failed PA 106 testing. If the application fails PA 106 testing, tl report shall state which portion of the test was failed; Category 1 (examination for loose tile) (,r Category 2 (uplift testing of tile). Subsequent to testing the installer may. repair not more than 5% of field area tiles and 10% of perimeter area (i.e. - ridge /rake) tile with .approved tile adhesive. The installer shall place an identifiable marking on each repaired tile for future reference.. Any PA 106 re -test shall not include any marked tile: 7. For mortar or adhesive set tile :applications, 30190 hot mopped underlavmcnt applications may be installed perpendicular to the roof pitch prior to June 1, 1995 unless stated otherwise by the material. • inanufacturer.. Thereafter ,'3.0 /90'nnderlayment systems shall be installed parallel to the roof pitch:in compliance with Appendix. 'A'•of Dade .county Protocol PA 120. - •.03/23/95 11:47 ''305 887 3283 MED ROOF TILES • . ; 8. Al) tiles shall bear the imprint or ,identifiable marking of the manufacturer' fi name or logo • for . identification in the field. The Altura "Altusa S" the profile has been tested for both wind characteristics and static Uplift performance, therefore, attachment calculations for installation in cornpliancu with Dade County Protocol PA 115 or PA 127 shall be done as a 'Moment Based System' 9. • 10: Applications for roofing permits shall include a completed Section II of the Uniform .$u ;lc4ing Permit, a copy of Altura Tile's current specifications and details, a copy of this Product• Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. li . 'rhe applicant. shall, retain, the services of a Dade County certified testing laboratory to maintain quality control in compliance.with the South Florida Building Code and related_protocols.,_ 12. Any amendments to these provisions.shall be in compliance with Sections 203 and 204 of the Florida Building Code, SYSTEM LIMITATIONS (CONTINUED) Product Controt No.: 94=0911101 • ll1 013 I elatt 4; rurbipring nnoments aue to Gravity - M (ft-lbf) . , from PA 102 Testing Tile Profile ' 3":12" - or less 4":12" . . 5":12" 6":12" 7":12" or greater Battens Direct Deck Battens Direct Deck Battens . Direct Deck Battens Direct Deck Battens Direct Deck Altusa 'S Tile 4.47 5.35 4.40 5.27 4,31 5.16 4.20 5.03 4 08 N/A - 03423/95 • Altusa 'S' Tile Tile Profile Altusa 'S' Tile 31.80 21.20 25.30 26.90 34.90 Screws for tile installation over shall be #3 x 2W long, corrosion resistan , Quik-Drive screws installed .in two manufactured holes located:1 and s/„" from the head of the tile. Altusa 'S' Tile 11:49 ffi.5_ 3283 Tile Profile Tile Profile Table 1: Aerodynamic Multiplier- X (ft') from PA 108 Testing X (ft Batten Application Table 3: Attachment Resistance Expressed as a Moment - M, (ft from PA 102 and PA 102(A) Testing TILE APPROVED APPROVED APPLICATION NAILS SCREWS 1 nail 2 nails 1 screw 12 screws Battens. N/A N/A N/A Direct Deck 6.20 8..40 28.70 • Table 4: Attachment Resistance Expressed as a Moment - from PA 101 Testing Mortar Set • • Adhesive Set • -.. • .. . . ' • DATA FOR ATTACHMENT CALCULATIONS 0.29 Tile Application MED ROOF T I LES 21014 Product Control No.: _24 (ft Direct Deck Application APPROVED FIELD CLIP WITH: 1 nail 2 nails M, (ft-Ibf) 0.31 APPROVED EAVES CLIP WITH: 1 nail I 2 nallS 26.80' N/A NIA N/A N/A. Attachment Resistance 24.50 66.50 . _ 03 11:51 eiT305_887 3283 MED ROOF TILES NQT.IcE P EAC.0 f.PTALYS ..5.1ANDARD CQNDl7'10N MET 1101'01 I l AN DADE C,ol1NTY, FLORIDA METRO - DADE FLAGLEfi 13UILDING fUILDINU CODE COMPLIANCE DEPARTMENT 8UiTE 1003 METi1O -DAUG. FLAGLER. (WILDING 140 WEST FLAOLEIl STREET MIAMI, FLORIDA 331313.1503 (305) 375 FAX (30f) 315.2009 • Extensions of Acceptance may he considered after a new application has been filed and the supporting data, test reports no.older than ten (19) years, have been re- evaluated. All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State .or. Florida. 2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination. unless prier approva).is granted for revisions or change. 3. Any unsatisfactory performance . of this product or process or a change in Codc provisions shall be grounds for re- evaluation. 4. This acceptance shall not- be-used as an endorsement of any product for sales or advertising purposes. 5, The Notice of Acceptance. number preceded by the words Dade County, Florida, and followed by 'the.. expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done.in its entirety. 6, Product approval drawings, w here required for permit applications, shall he provided to the applicant by the manufacturer or his distributors unless otherwise noted in the Notice of Acceptance. The prints'need not be re- sealed by an.engineer. 7.. Failure'to comply with the Standard Conditions shalt be cause for termination of the Approval. This approval supersedes ;ill ii ■dslous :tppiovals. Last Approval Number 14 =0°6.1s t , ) 1 t y Raul Rodriguez Product Control Division Supervisor (1016 ..03/L/95 11:50 '8`305 887 3283 MED ROOF TILES . li 1, r f t s, • cla nvot T,Ics PROFILE DRAWING A.LTUSA'S TILE 10" 015 Product Control No.: Q4.0914.01 7 Process Job Address: e37/1/ C 5' 8S/ Contractor No. 123.01-166 9/94 Base Sheet: Fasteners: Ply Sheet(s): Cap Sheet: Asphalt: APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II BUILT -UP APPLICATIONS AND MODIFIED BITUMEN SYSTEMS GENERAL: Type of Roof System Assembly to be Applied: Manufacturer of Roof System Assembly: Product Control Approval Number: System Number from Product Control Approval: 6°4 0 S g �f : bZl ! .JL2 /4/( 8 z -- ( 7 (Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System Guide Specification. ) ( Note: If a minimum roof system is to be applied, describe all components within the system and list the manufacturer of each component. DO NOT complete this section if system is Product Control Approved. ) ( Note: No insul • tion system is acceptable under the minimum roof category. ) Complete the following for all Roof System Assemblies: Built -Up Applications and Modified Bitumen Systems Page -1 Job Address: 057 * 9Bs Contractor (/Process No. Job Address: Contractor Process No. r� ( Check* one of the following) Recover Re-roof: y If a recover, is the existing Roof System Assembly to be used as a bonding substrate ?: If YES, has an ASTM E907 test been carried out to confirm adhesion of the existing membrane to the substrate ?: (If yes', attach AS7'M E907 test report. ) Proposed Fastener: (Attach withdrawal resistance test report. ) Has the deck been examined for moisture ?: (Provide data confirming compliance with Section 3401.9(c) . ) THE SYSTEM: Deck: (Briefly describe) Insulation: ( Type, size and method of attachment, if applicable ) Base Sheet or Ply: ( Type and method of attachment ) New Construction n1/4'6 J S. / 11 N All Roof System Assemblies in the Product Approval have a variety of options. Briefly describe the Roofing Components to be used in the Roof System Assembly and attach a copy of the manufacturer's published specification: = 64 -p14 .t L Ply Sheet(s): el *oa, P f/v. Type and method of attachment) �> j Built -Up Applications an M o d fied Bitumen ems / � �� Page -2 Reviewed Field Test Data ?: Notes: Additional Notes: Built -Up Applications and Modified Bitumen Systems Page -11 Y N Plan Examiner Job Address: — FOR PLAN EXAMINER USE ONLY — Roof System Assembly Product Control Approved: Y N If NO, note any deficiencies: Design Pressure Requirements: Field: psf Perimeter Areas: psf Corner Areas: psf Note any limitation Reviewed Details ?: Contractor Process No. Y N Notes: 1. • Job Address: cif/ fie $ Contractor %i / Process No. Top Ply: (Type and method oj attachment ) Surfacing: (Type, if applicable ) Flashing Materials: ( Type and method of attachment ) / Built -Up Applications and Modified Bitumen Systems Page -10 Built -Up Applications and Modified Bitumen Systems Page -3 f 7 /o "" e /a/ py4ci / �� Job Address: 251 t tY 9eS( Contractor tl/fij Process No. inches 1 inches inches 1 FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND INSULATION LAYER(S). (Where Roofing Component not used in Roof System Assembly, fill in with "N /A ".) g Top Ply: lit a l.. � 7 � 4.1 Ply Sheet(s): �/ 1 y � p (U l V F l N (i Dale sheet mech. attache ) Base Sheet: t1 Surfacin : (briefly describe, (applicable) Primer. (1/ applic Bond' gMat ��►+•p. }gip ( p Bonding Mat 1 . : 4 67 I.: Rab Bondingq Material: ∎ ) (i r Fastener: (if top insulation mech. attached) Top Insulation if applicable ) Bi op ou d :i werial: layer bonded ) Fastener: (if insulation mech. attached) Insulation: Built -Up Applications and Modified Bitumen Systems Page -4 Bonding Material: f (1 insulation bonded ) � Vapor Retarder: ( ifapplicable) DECK: Type: Gage or Thickness: , Density, if concrete deck: a • • O z to a) U O Job Address: Contractor Process No. Insert Building and Parapet Heights. (If no Parapet exists, insert "N/A") Also insert applicable information pertaining to the building below. (See ASCE 7 -88 Fact Sheet Attached ) Exposure Category: Classification Category: At Hurricane Oceanline ?: Y N Basic Wind Speed at Building Location: 110 mph Building Condition based on % of Openings: GROUND LEVEL t feet I I a' keet BUILDING INFORMATION #1 Built -Up Applications and Modified Bitumen Systems Page -8 ,/� Job Address: ?/r F9/5 Contractor �� �f rocess No. PERIMETER DETAIL #1: Parapet Wall Detail Coping Cap Gage: Fastener Spacing: _ o.c. Clip Type: Clip Gage: Ve/ Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Parapet Walls. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Areas to be Flashed. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. PERIMETER DETAIL #2: Flashing Detail Built -Up Applications and Modified Bitumen Systems Page -5 Job Address: Contractor PERIMETER DETAIL #3: Gravel Stop or Drip Edge PERIMETER DETAIL #4: Gutter Detail Built -Up Applications and Modified Bitumen Systems Page -6 Process No. Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gravel Stop or Drip Edge. Insert leaders indicating Roofing Components names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment Gravel Sto. a '. Edg Gage: , Fastener 2 Spacing: l o.c. Clip Type: Clip Gage: Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gutters. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment Gutter Type: Gutter Gage: Fastener Spacing: Deck Type: Job Address: Contractor PERIMETER DETAIL #5: 'Other' Detail Process No. Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may eitisit Insert leaders indicating Roofing Component names, dimensions, thickesses, etc. Include fastener type and spacing used for wood - blocking attachment Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may exisit. Insert leaders indicating Roofing Component names, dimensions, thickesses, etc. Include fastener type and spacing used for wood - blocking attachment. PERIMETER DETAIL #6: 'Other' Detail Built -Up Applications and Modified Bitumen Systems Page -7 Q3/12/95 21:04 $3055979484 • • .iii1ineral Surface /4 Ply Roof • With Nailable Deck SPECIFICATION NOS. M- B4TP -N, M- B4SP -N ' ASPHALT TWO PLIES TOUGH PLY IV ONE PLY ULTRA BASE MATERIAL REQUIREMENTS SPECIFICATION NO, TP -N (Eligible for 12 Year Premium Warranty, Zone A) MATERIALS: Mechanical Fasteners - as required INTEC /PERMAGLAS ULTRA BASE 2 - 1 Ply INTEC /PERMAGLAS TOUGH PLY IV - 2 Plies INTEC /PERMAGLAS ULTRA CAP Asphalt - as required Accessories and Flashing Materials as required APPLICATION RECOMMENDATIONS ROOF DECK shall be firm, clean, dry and smooth. All membranes shall be applied so the flow of water is over or parallel to, but never against the laps. INTEC /PERMAGLAS ULTRA BASE Lap 2" (5 cm) on sides, 4" (10 cm) on ends • and turn up to top of the cant. Nail on 9" (23 cm) centers through the lap 'and on 18" (45 cm) Centers along a line 12" (30.5 cm) from each edge. VALLEYS AND WATERWAYS shall receive an extra layer of TOUGH PLY IV which shall be at least 36° (91 cm) wide and shall extend at least 8° (20 cm) up the inclines out of the valleys, set in a uniform mopping of hot asphalt, optimum of 25 lb /square (1.2 kg/m This ply shall be laid prior to the application of the roofing plies. INTEC /PERMAGLAS TOUGH PLY IV end laps shall be at least 4" (10 cm) and adjacent end laps shall be at least 12" (30.5 cm) apart. Install two plies of TOUGH PLY IV in shingle fashion, lapping 19" (48 cm) with a 17 (43 Cm) exposure. Starter strips of 18" and 36" (45, 91 col) shall be usecfand the second full sheet shall be laid a maximum of 16" (41 cm) exposure. Embed the full width of each ply sheet in hot asphalt, optimum of 25 lb/square (1.2 kg/m Each ply shall be lightly broomed as it is applied. Turn up all plies to top of cant. INTEC /PERMAGLAS p LTRA CAP shall be cut into maximum 18' (5.48 m) lengths, the length depending upon temperature and weather condi- tions, and allowed to relax. Embed ULTRA CAP into a uniform solid mopping of hot asphalt, optimum of 25 lb /square (1.2 kg/m Set neatly in place with 2" (5 cm) side laps and 6" (15 cm) end laps. Adjacent end laps shall be at least 3' (91 cm) apart. There must be complete adhesion between the ULTRA CAP and the mopping asphalt. Apply extra pressure to avoid creating open channels, where three or more membranes are lapped. BASE FLASHING: All warranty roof systems must be flashed according to the "Flashing Details ", Section 7. All of the Recommendations and Application Techniques set forth in this manual are considered part of this specification. ' NOTE TO SPECIFIERS: SUPER PLY ( "SP °) may be specified in Zone A only (See Zone Map pg. 36). To specify, call out specification M- B4SP -N and use the words SUPER PLY in place of TOUGH PLY IV wherever they appear in this specification. 2 Permaglas Bondable Base Type 28, Combination Base, Flex Base30. Type 40 Smooth or Permavent may be substituted for Ultra Base. NAILABLE DECK BRADCO MIAMI ASPHALT [1001 Mineral Surface /3 Ply Root With Niiilable Deck SPECIFICATION NOS. M- 63TP -N, M- B3SP -N' ONE PLY TCUGH PLY IA' ONE PL ULTRA BASE ULTRA CAP NAILABLE DECK MATERIAL REQUIREMENTS SPECIFICATION NO. M- B3TP -N (Eligible for 10 Year Standard Warranty, Zone A) MATERIALS: Mechanical Fasteners - as required INTEC /PERMAGLAS ULTRA BASE' - 1 Ply INTEC /PERMAGLAS TOUGH PLY IV - 1 Ply INTEC /PERMAGLAS ULTRA CAP Asphalt - as required Accessories and Flashing Materials as required APPLICATION RECOMMENDATIONS: ROOF DECK shall be firm, clean, dry and smooth. All membranes shall be applied so the flow of water is over or parallel to. but never against the lap, INTEC /PERMAGLAS ULTRA BASE Lap 2" (5 crn) on sides. 4" (10 cm) on ends and turn up to top of the cant. Nail on 9" (23 cm) centers through the laps and on 18" (45 cm) centers along a line 12" (30.5 cm) from each edge. VALLEYS AND WATERWAYS shall receive an extra layer of TOUGH PLY IV which shall be at least 36" (91 cm) wide and shall extend at least 8" (20 cm) up the inclines out of the valleys, set in a uniform mopping of hot asphalt, optimum of 25 lb /square (1.2 kg /m This ply shall be laid prior to the application of the roofing plies. INTEC /PERMAGLAS TOUGH PLY IV end laps shall be at least 4" (10 cm) and adjacent end laps shall be at least 12" (30.5 cm) apart. Install ore ply of TOUGH PLY IV in shingle fashion, lapping 2° (5 cm) with a 34" (8ti cm) exposure. Embed the full width of each ply sheet in hot asphalt ,optimum of 25 lb/square (1.2 kg /m Each ply shall be lightly broomed as it is applied Turn all plies up to top of cant. INTEC/PERMAGLAS ULTRA CAP shall be cu: into maximum 18' (91 cm) lengths. the length depending upon temperature and weather conditions, and allowed to relax. Embed ULTRA CAP into a uniform solid mopping of hot asphalt, optimum of 251b /square (1.2 kg /m Set neatly in place with 2" (5 cm) side laps and 6" (15 cm) end laps. Adjacent end laps shall . be at least 3' (91 cm) apart. There must be complete adhesion between the ULTRA CAP and the mopping asphalt. Apply extra pressure to avoid creating open channels, where three or more membranes are lapped. BASE FLASH- ING: All warranty roof systems must be flashed according to the "Flashing Details ", Section 7. All of the Recommendations and Application Techniques set forth in tivs manual are considered part of this specs ication. ' NOTE TO SPECIFIERS: SUPER PLY ( "SP ') may be specified in Zone A only (See Zone Map pg. 36). To specify. call out specification M- 83SP -N and use the words SUPER PLY in place of TOUGH PLY IV wherever they appear in this specification. ' Permaglas Bondable Base Type 28. Combination Base, Flex Base30. Type 40 Smooth or Permavent may be substituted for Ultra Base. These specification are eligible for an INTEL/ PERMAGLAS ROOFING WARRANTY. when in the opinion of an authorized Intec.Permag'as 1";L•ctor. as condition; in our current 'Rooting Systems Manual" have been met. and the publisned requirements of implementing a "Built -up Roofing ■Var;a -,,r .•a•. E :een completed. INTECIPERMAGLAS - Roofing and Waterproofing Systems 52 03/13/95 i 03:51 x`3055979484 Five and Ten Year Standard Warranty Specifications DECK TYPE INSULATION NAILABLE Type of Surface ALN = Fibrated Aluminum E = Asphalt Emulsion ECG = Emulsion and Chopped Glass ERA = Emulsified Aluminum G = Gravel or Slag GMA =Gravel/Slag with Flex (SEBS) Asphalt M = Mineral Surface Cap (Ultra Cap) 730 = Mineral Surface Cap (Ultra Cap 730) BF4.5 = U.S. Intec, Brai /Flex FR -4.5 BF3 = U.S. Intec, Brai/Flex FR -3 8F170FR =U.S. Intec, Brai /Flex 170FR BF170 = U.S. Ir'tec, Brai /Flex 170 BFG3 = U.S. Intec, Brai/Flex G3 Cap Total Number of Plies in the System (Base Sheet, Ply Sheet, Cap) SURFACING GRAVEL GRAVEL �' `'MtNEFtAL CAP ; . MINERAL CAP ASPHALT EMULSION EMULSION :1 ALUMINUM EMULSIFIED ALUMINUM FIBRATED ALUMINUM 7 ' FIBFiii -fe ALUMINUM - ' EMULSION CHOPPED GLASS EMULSION CHOPPED GLASS GRAVEL GRAVEL MINERAL CAP + ' 1 ig:WERAL r-" UL. SPECIFICATION NUMBER M- T3TP -RI E- 3TP -RI ERA 3TI -RI EFIA•3SP -RI ALN- 3TP -RI : ALlJ- 3SP =Rl_ ECG - 3TP -RI ECG - 3SP -RI G- 3TP -RI ALL G- 3SP -RI ZONE A M- 64TP�il` .. ALL M- B4S41 ZONE A ALL • • ALL • ZONE A ALL ALL ZONE A G- B4TP -N . G- B3TP_N .,.. . G- B3SP -N M-B4TP-N ASPHAL SION N BRADCO MIAM GUARANTEE CLIMATIC. - ZONES 77:.• LSION 4 ,- ALL � .. -- _E1Mr.14 ' E AIP_UIINUM ":; .. .. ERA- B4TP. -N FIBRATED ALU KEY TO SPECIFICATION NUMBERS G- B4TP -N ease Sheet used In Specification B = Intec/Permaglas Base Sheet as Specified: Combination Base; Ultra Base; Bondable Base; Flex Base 30. P = Intec/Permaglas Permavent RI INTEC /PEPMAGLAS * Rco!in. a .. ". - • Part 3 - Intec /Permaglas Specification Index RECOMMLNDED SLOPE RANGE ALL 1/4" -3., ZONE'A " '/4' -3' ZONE•A _:. . . 1/4" •3" ZONE A y ," _3" ZONE A, B "'ZOIWK: '/4" -3" '/ -3" t ' /4' -6" ' /a' -6' ,/4+ 6" '/4" -3" • '/4" - 3' '/4' -3' ' /4+ -3" '/ - ' /4• -3' ' .3 " EMULSIFIED ALUMINUM ERA- 84SPAI ZONE A _ -B4TP N ALL BF FED :A :A M1t113M T ATN -843P'TQ '` Z01+7EA ,;jEMUL,SION;CIi ED.•C3LASS EOSa 4TT�Nc,. z . ALL EMULSION CHOPPED GLASS ECG- B4SP -N b. t�-•✓4i°"T ' --- - -- __S_� ZONE A ' /a' •3" f 4s us iF Y o I - a � �on tom a ec Type of Interply Felts SP = Super Ply tensile strength meets ASTM D 2178 -89, Type 111 specifications. TP = Tough Ply IV, ASTM D 2178-89, Type IV. UP = Ultra Ply VI, ASTM D 2178 -89, Type VI. FB = FLEX BASE 30 P = Perma Poly 185 la 0 U.L. CLASS SLOPE RANGE PAGE NUMBER A O" -3" 42 A -2%; 43 A 0° -2' 44 'A 0' -1'/2" 46 ‘77F0 ~:r':. 46 48 . 'A 0' -2" 46 'A 0'-2° 46 0 2•,/,;;• 46 A 0' -'/2" 46 A 0' •' /a° 46 A O" A 0" -3" '/e -6" A 0 2 52 .1/4'.-6" ' :. ..;:.: ti . . 5 '/4' -6' 4',0 . 52 '/4" - 6" A 0 - '12' 52 l / 4 - B 0" -'/2' 1 /4'.9' f �0 2/z/ 7 7".- _.4`. . . • . -3' ::. % 2 "?' •": 54 ' /4' - 3" B 0' - ' /2" 54 '/` -3" 8 8 0 -'/2" 54 '/4' -3" • - ,.tfB 0. „ ,..g rF�"r ' 4) 54.. . ,.L'_ /4' - 3: a �. r O `. ` oft ._ A 0' -1' 54 50 •,50 51 51 Substrate/Type of Deck C = Nonnailable IB = (Eye B) Instil-Base, required over isocyanurate and urethane isulation'. = (R Eye) Perlite, wood fiberboard, fiberglass, USIROC WOOL Roof Insulation'. LWC = Lightweight concrete N = Nailable decks - wood, plywood, wood composition, gypsum, and tectum. ' 'RI° and 1B” specifications may be used over all types of substrates: nailable, concrete, steel, etc. 2. Lightweight concrete decks must have Permaglas Permavent, ° inverted° Ultra Cap, or 3 /4' Perlite over new construction. ' 02/10/95 00:35 $3055979484 BRADCO MIAMI mETRODADE Applicant: IntedPermaglas Div. U.S. Inter. Inc. 1212 Brai Dr. Port Arthur, TX 77643 Category: Membrane Roofing System Sub- Category: Built -up Roofing Type: Conventional Sub -Type: Fiberglass BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO-DADE FLAMER BUILDING Ma WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 Product Control Notice of Acceptance FAX ( 3a5 375-2901 Roofing System Approval Technical questions should be addressed to the Technical Hotline at 1 - 800 624 - 6832 METROPOLITAN DADE COUNTY_ FLORIDA METRO - DADE FIAGLEA BUILDING Product Control No.: 94 0211.02 O Approval Date: Expiration Date: February 14, I994 February 14,199? Intec/Permaglas, a manufacturer of commercial built -up and modified bitumen roofing systems, produces a wide range of roof products For hot and cold applied built -up and modified bitumen roofing systems. In addition Intec/Permaglas offers built -up root with SBS modified cap membrane.. The IntedPermaglas Roof System Assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material Directory and the current Factory Mutual Approval Guide. Intec/Permaglas membrane systems may be installed in new construction and reroofing projects. Built -up roof specifications can be found in the "Built - Up Roofing Systems Manual' published by IntecJPermaglas annually. InteclPermaglas provides warranted systems over various insulated and non - insulated substrates. Intec/Permaglas systems and products are distributed through roofing wholesale distributors in the South Florida jurisdiction. Gil Diamond. P.E. 002 02/10/95 00:35 $3055979484 rr-rr —dr— • 4 r K t rJrt: ! U O i r l r, I.t.. Product Bondable Base Braltticx Walkboard • Combintdon Base Drill TecT 3 Meat Stress Plato Drill TecTM Coated Drill Point Screws Drill Teem Lit4Deck Fasteners Drill Tec Plastic. Plata Drill Teem Stainless Steel Screws Drill TecTH Tap RripT" Concrete Deck Fastener Flex Asphalt Flex Base 30 Gravel Guard MB Carton weight: 60 lbs. vwriagS M Trade Names of Products Manufactured or Labeled by Applicant Dimensions Roll weight: 67 lbs. 3' x 3'; Roll weight. 18 lbs. Roll weight: 67 lbs. Roll Weight 82 lbs. 3 Test Spaifievions ASYM D 4601 TypeL ASTM D 5147 ASTM D 4501 Typo I ?All4 M 114 PA 114 PA 114 PA 114 PA 114 BRADCO MIAMI ASYM D 312 Type t1T oc IV ASTM D 4601 Type, u Ptoprictaty Product Control No.: 94 -0211.02 Product DeSariptiott Type 17 asphalt impregnated and coated glass fiber bast sheet for use in conventional and modified bitumen built.up roofing. Granular surfaced SAS modified asphalt membrane walkboacd. Type I asphaltimpregnatcdl and coated Van fiborbase sheet a folly laminated kraft paper bucking for use in Conventional eod modified bitumen bvllt- p roofing on wood decks. Cali/demo 3' round mesa plate. Contu[on resistant, drill point threaded l'RtUlstion fastener. Nylon insulation fastener for tecwm gypsum and lightweight concrete. Polyolifut 3' round plastic stress plates. Stainless steel. ddtll point threaded Insulation festeaer. Corrosion reslstarlt. insvietion fastener (concrete only). Hot applied bitumen adhesive used to conventonal and modified bull- up rooting. modified with SEBS poiyaue. Type iI espha[t Impregnated and coated glass Aber base abaci for use in convention") and modified bitumen built -up roofing. Maui edge gravel guard with patforarad Diamond. P.E. 12003 40002 62/10;9,5 00,;,30, $3055979484 • ,..0ti/27r'��3 07 53 $`305 375 2904 Insal -Base Roll weight 67 lbs. ASTM D 4601 Type I tutee perrnaglas RovGag Carton weighs 100 ASTM D 312 Asphalt lbs. MDraln MPan MScupper Matrix SB Matrix S8 Trowel Grads 5 or 55 gallon Permavent Pretreated Lead Seek various Quick Pitch Quick Pitch Standard, Adjustable, One various Way Mvopt Tough Ply IV Type 40 Smooth ruiow Proprietary 6"x6" Proprietary vaCiees Proprietary S or 55 gallons ASTM D 112 AST1.4 D 4586 Roll weight 72 lbs. ASTM D 4897 TYPerl Roll weight: 67 Ibs 4 BRADCO MIAMI Z004 CODE COxPLI& CE Proprietary ASTM D 4536 ASTM D 4586 PA 110 Product Control No.: 94.0211,02 flange. Type I asphalt impregnated and coated perforated glass Mar bear sheet for vie is COar'entieaal end modified bitntnea built -up roofing, Hot applied Wewmee adhesive used in eotivendoaal and modified bitsurteat bruit - up roofing. Spun aluminum or copper roof drum with gravel guard, strainer nip and water.proo&ag 5caL A. prefabricated pitch part and modified bitumen flashing assembly for rata wheto roofprotrusione require plat pocket`, Prefabricated scupper and =Mad bitumen fishing assembly used for rata and retrofit scupper installation. S9S =edified asphalt adltaive for bonding tap and ply sheets` SBS modified roof current for bonding tashing mssetiais. Heavy duty fiber glass Use sheet impregnated and coated on both sides. Surfaced on the bottom side with coarse mineral grannies enbedded Ill hot asphaltic coating. Predicated 'ad pipe waterproofing assembly, A pourable, potyurerhanc sealant for use in caPPlng p per. A twe.Cetuponent adhesive and srala=t system foe firltug and capping pitch pans. Prefabriacted stack eaves for use its soil pipe waterproofing. Roll weight 46 lbs. ASTM 17 2178 Type N asphalt impregnated glass felt for fyps Iv use le cvnvedzioesl cad modified bitvatsa built -up roofing. ASTM D 4601 ypeU asphalt impregnated and coated glass fiber base sheet for use in ® 003 02/10/95 00:37 $3055979484 MAY -27- -' 94 FR 1 ea: 5S {1.11.1 $A-31- r rvt. r rub USIROC Wuot Root • 4' x 4', 4' x 3' Insulation USIROC Wool Taper 4' x 4' Roof mulatto' USUo Perilte Composite 4' x 4', 4' x 8' Root Insulation USW Roof Insulation 4' x 4', 4' x 8' UStso Taper Roof insulation Ultra Base Ultra Cap Ultra Ply VI Usikant•PR 4' x 4' PA 110 PA t1O PA 110 PA 110 PA 110 BRADCO MIAMI 1c.1_ 1`u:1 .513 toe 7 r o0 Coos cosEPLIANCE o'a.a Product Control No.: 94.0211402 coaveetlonal and rnedifle4 bitumen bulb up roofing. Basalt reek laau ?aeion• Tapered basalt rock insulation. PaIyisocyantmte foam insulation with K' partite laminated to Oat side tad at Plus facer on the othw. FaIyisoeyaaurate foam insulation. 'Tapered potyisxyanuraze team insulation. Rob weight; 67 lbs. ASIM A 4601 Type II asphalt impregnated and coated Type n glass fiber base shut for use in conventional and m liti d bitumen built-up roofing. Roil weight: 72 Ibs. ASTM D 3909 Asphtlt Impregnated and coated felt Surfaced vdth mineral granules used as the top ply in conventiottel built-up roof membranes. Roll weight46 lbs. ASIM D 2178 ZYpe VI Proprietary Typo VI asphalt impregnated glaze felt for use In epaveitti4nal IN modified bitttmeo built-up tooting. Gat strip made from bawler; rock. tegr va r_S 1:4•:•.• 1 � ~ ` e . ; - � 2•. i4Yt} .■ M �? • J _ Z005 • 02/10/95 00:37 '83055979484 Ccof Cara bedian Director - Systems Developme Fax: 313- 288 -9788 1250 Fourteen Mile Road Suite 103 Clawson, MI 48017 313 435 -0022 BRADCO MIAMI 41] uuo iz/1$ 04:43 • Membrane Types SBS Deck Typo 1: Deck Descriptions System Type E: A11 General aad System Limitations appl Overlay Board: Base Sheet: Fastening: Ply Sheet: Mgmbra m Surfacing: Maximum Design Pressure: Maximum Fire Classification; Maximum Slope: Specification No.: Wood Deck System Limitations: $` BRADCO YIAXI Wood, Non - insulated 17u" or greater plywood or wood plank decks Base sheet mechanically fastened. (Optional) Type X gypsum board or Dens Deck loose laid over deck. Oral Flex S, Flex Base 60, Inter Modified Base Plus, Flex Base 30 or Ultra Base fastened to the deck as described below: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c.. (Optional) One, two or three plies of Tough Ply IV or Ultra Ply VI or one ply of Brai/Flex FR2, Flex Base 60, Brai/Flex S, Intec Modified Base Plus, Flex Base 30 or Ultra Base adhered with full mopping of approved asphalt at an application rate of 25 lbsisq. t 15 %. RraifFlex FR 3, Broil. I'R C.p Drat/flex hit 4 S, Ultra Cap !atomic( 730 (babe and ply sheets required) Brai/Flex 170 FR or Brai/Flex 250 FR adhered with full mopping of approved asphalt at an application rate of 25 lbsisq. f 15 %. (Optional, in place of membrane) One or more plies of Brai/Flex S. Intec Modified Base Plus, Flex Base 60, Flex Base 30 or Ultra Base adhered with full mopping of asphalt at an application rate of 25 lbs./sq. * IS% and surfaced with a flood coat of asphalt at a minimum rate of 60 lbsisq. and 400 lbs. of aggregate. -45 psf. Class 'A'; sec General Limitation #2. 14 :12; see General Limitation #3. BF- 200-N, BF-300-N, BF- 400-N, BF -500 -N 1. A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to wood plank deck. A red rosin sheet may also be installed on plywood decks as an option. 2. Pre-assembled 'Cap Nail' shall not be used for b Gil Diamond, P.E. 32 Product Control No.: 94-0920.19 Q014 02/10/95 00:38 $3055979484 apt} zeoa MIUox -? Py vox White Lino ACFoarn.II ACI oam ACFt *m•11 Composite Various Hy-Tec and By- -Tee 11 various Hy Chest AP various vadous various v dour Anehorbond Fastener DekPut Fastener Gripdek Fastener various v Hy -Thctm Nail -Line various Product Dimension Test ' ica4�oru PA 110 PA 110 • PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 110 PA 114 PA 114 PA 114 6 BRADCO MIAMI •.... 1 ..J.. v +.nl .rw - . W CODE COIN. rA CE • Trade Names of Products Manufactured by Others Product Description Polyisocyanurete foam and Apache Products Co. composite ittsulatiod Polyisoayanurarn foam Apache Products Co. insulation Polyisocyanurate foam and Apache Products Co, composite insulation PolYisocyanurata foam .Atlas F.ttetgy Products instttatlon. Polyisocyanurate foam insulation Composite insulation Atlas Roofing board. Products Palyisocyantata foam insulation. Poly socyanuuate foam insulation Palyisocy *nurate foam insulation Insulation fastening Assembly Insulation fastening Insulation fastening assembly Product Control No.: 94.0211,02 Manufacturer Ades Roofing Products Cobras Celotee Celotax CQnstructic►n Fasteners Construction Attune's IT'W Builder 007 oos - 02710/95 00:38 2230559794.$4_ - OS /27/9e 07:55 kissed Fastener Hoxtra Fastener Roofgrip Fastener ISO 95+ Karnak 97 AF E'NRCY = ENRGY 2 Composite : various ENRC'Y 2 Pius Composite ISORoc Nail -Tito Type R Fastener Con T c Fastener Olympia Fastener Guest Striker Fastener GiasFast Fastener Parou 233OS 375 2508 • arloae - gyrati various various various PAIL4 PA 114 PA 114 PA 110 ASTMD28 4 Typo Ill PA 110 FA 110 PA 110 PA 110 PA 114 PA114 FA114 PA 114 PA 114 PA 110 7 BRADCO MIAMI CODE COttPLi c2 � • " Ptoduer,CoatroP No.: 94- 0211.02 Insulation fastening 1TY! Buildex assembly Insulation fastening 11W au;tdex assembly Insulation fastening 1TFiI Buildex assaably Polyiaocyanurare foam raternedooal Pe uslite • laudation Aluminum roof coating- Karnak Chemical Co. Polyisocyeaarata fog rn NRG Battlers. Inns insulation. Composite insulation MG Barriers. Inc. boatel. Composite insulation rtRO Battlers,1nc- boud.. Pnlyisoeriraurate foam NRO Battlers, Inc. insulation, buulatioalbase sheet Pisii Tits fastening assembly. insulation fa5tsniag systan Olympic Fsste980 Insulation fastening Olympic Pastgaeets Insula$on fastening system Owens Corning Owens - Corning Fartck, Inc. assembly Insulation fastening assembly Non woven fiberglass mai �J 008 ii;g ooe 02710/95 _ 00_49.._ 305597984. Test Agency Tut Ide b'£er Tcst NarneiReport _ Dam Factory Mutual Research • LL 3 ZN►GAI.AM Wind Uplift and Pita 09109192 Corporation Classification FMRC Factor' Mutual Rcscsarrh ).L 0 0R9A6.4M Corporation. Underwriters Laboratories FMRC 1993 Currant Insulation 01/01194 Fastertlitg Requirements FMRC Approval Guide 1993 Test Reports BRADCO MIAMI l.v. A. .J... Qrtrunt Insulation Fasteaiog Regaircutenc3 FMRC Approval Guide 1993 Product Conttoi No.: 94.0211.02 01/01194 Wind Uplift and Fire 01/02/90 Classification Fire Clasrifiesrion -- see 1249/93 wtrattt directory f�] 01 4. sir/; 5. 02'710/95 ML jAo DApE 00:40 $3055979464 BRADCO MIAMI METROPOLITAN DADS COUNTY, METRO.DADE FLAGLER BUILDING COMPLIANCE DEPARTMENT METFID-DADE FVy SUITE 1603 140 W GLER BUILDING MUM FLAGLER STREET LORIDA 33130.1563 (305) 375.2901 (• application (305) 375 -290e tesr reports no older than ten (10) yam, have be re Extensions of Acceptance may ve considered after a new ation h been filed and the su _ ; g PPorting data, Florida. reports of re bear the seat, signature and date of an engineer re A stored !n the State of 2• erial a the ang c revision ion or he in th mts, use, or manufacture of the Any for ion o r h an, a in unless th p app s, use, is Product or process shall automatically be 8ranted for revisions or change. 3 • My unsatisfactory performance of this product or process or a change in Code re- evaluation. e Provisions shall be grounds This acceptance shall not be used as an endorsement of any product for sates or advertisi The Notice of Acceptance ng Purposes. Ae The Notice dat may p t displayed number in preceded s h b l it he words Dade County, displayed, then it shall be done in its entirety. g literature. If any the Florida, and followed by the Y P °rt'vn of the Notice of Acceptance is 6. Product approval drawings, where required for permit applications, or his distributors unless otherwise noted in the Notice 0fA provided to the a re- sealed by an engineer_ PPli�ni by the Acceptance_ The prints need not be 7 . • Failure to comply with the Standard Conditions shall be cause for termination ofthe Approval. 1 11 Diamond, P.E. ��/� ✓1 - Product Control Division Supervisor V• METRO-DADE Polyfoam Products, Inc. P.o. Box 1132 Spring, Texas 77383 -1132 METROPOLITAN DADE COUNTY. FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375-2901 FAX (305) 375-2908 PRODUCT CONTROL NOTICE OF ACCEPTANCE Revised: Your application for Product Approval ofpolvfoam Products. Inc. Polvpro AHI60 Adhesive under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and types of Construction, and completely described in the plans, specifications and calculations as submitted by Miles Laboratories, Inc. and Center for Applied Engineering, Inc: has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the specific and standard conditions set forth herein. The approval shall be valid for a period of three years. The Building Code Compliance Department reserves the right to secure a product or material at any time for a job site or manufacturer plant for quality control testing. If product or material fail to perform in the approved manner, the Code Compliance Department may revoke, modify or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require testing of this product or material should any amendments to the South Florida Building Code be enacted affecting this product or material. The expen'•. of such testin3 will be incurred by the Manufacturer. PRODUL NO.: 94- 0401.01 APPROVED 05/09/94 COWL+ J lrt rer? t; ACCEPT.. NCE NO.: 94 - 0401.01 GEFIDiamond, P.E. Product Control Division EXPIRES: 05/09/97 Supervisor - PLEASE NOTE - THIS IS THE COVER SHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger, P.E., Director Building Code Compliance Department Metropolitan Dade County Catego `v; Roofing Component Sub - Category: Fastening/Adhesive Type: Roof Tile Adhesive Sub -Type: Two Component Polyurethane Product Control Notice of Acceptance Roofing System Approval Applicant: • Polyfoam Products, Inc. Product Control No.: 94- 0401.01 2400 Spring - Stuebner Road Spring, Texas 77383 -1132 Approval Date: 05/09/94 System Description Polyfoam Products, Inc., produces two- component expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® AH160 is specially designed for application of concrete and clay roof tile over a variety of roof deck substrates and underlayment materials. Polypro® adhesive is applied with proprietary Foampro® RTF1000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTF1000 dispensing equipment. Alterna•'ve methods of dispensing will require a revision to this approval. Prlyprc't0 adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products, Inc. Certificates and identification cards are issued to applicators upon successful completion of a application trainin program. Approval of this adhesive system is contingent upon application by a 'Qualified Applica.ar. Contact: Pat Murray P.O. Box 1132 Spring, Texas 77383 -1132 (713)350 -8888 Fax: (713)288 -6450 0. (AA X)" O Gil Diamond, P.E. Expiration Date: 05/09/97 • Trade Names of Products Manufactured or Labeled by Applicant Product Control No.: 94- 0401.01 Test Product Product Dimensions Specification Description Polypro® AH160 N/A PA 101 Two component polyurethane Foampro® RTF1000 N/A See Detail Attached Dispensing Equipment 2 CI AMt adifILM G Gil Diamond, P.E. Product Underlayment Roof Tile Test Apencv Center for Applied Engineering Miles Laboratories Polymers Division Propgm: lic�ib�iy Compressive ASTM D 1621 Strength Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor ASTM E 96 Transmission Dimensional ASTM D 2126 Stability Closed CeII Content TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Criteria PA 120 PA 101 All roof tile systems having tested in compliance with Dade County Protocol PA 101, as detailed in the systems section of this Component Approval TEST REPORTS Test Identifier #94 -060 NB -589 -631 Typical Physical Properties Test ASTM D 1622 ASTM D 2856 Product Description All Dade County Component Approved products as detailed in Dade County Protocol PA 120 Test Name/Report Metro Dade Protocol PA 101 ASTM D 1623 1.6 lbs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ft 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158 °F., 100% Humidity, 2 weeks 86% Product Control No.: 94- 0401.01 Typical Results Manufacturer All Dade County Approved Products All Dade County Approved Products att 04/08/94 02/01/94 Note: The physical properties listed above are presented at typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. 3 QC P uVl►'Yi�Ut Gil Diamond, P.E. BRAND NAME: GENERIC PROFILE: PLACEMENT DETAIL # Mission Barrel Two -Piece Barrel #1 Mission "S" Spanish "S" #2 Spanish "S" Spanish "S" #2 Classic 100 Double Roll #3 Villa _ Double. Roll __ #3 Vanguard Roll Double Roll #3 Slate Large Flat #4 Shake Large Flat #4 Flat Vanguard 1 Large Flat r #4 Flat Vanguard II Small Flat #5 Bermuda Flat Small Flat #6 Product Control No.: 94- 0401.01 SYSTEMS Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 " :12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System A Manufacturer: Monier Roof Tile Corporation Underlayment: Any approved underlayment listed in the Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification(Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. 4 Q op DUVIY1 Gil Diamond, P.E. Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum "/ or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System B Product Control No.: 94- 0401.01 Manufacturer: Bender Roof Tile Industries, Inc. Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: BRAND NAME: Palema Noridic GENERIC PROFILE: Double Roll Large Flat PLACEMENT DETAIL # #3 #4 All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. 5 9dte0+ aaVra Gil amond, P.E. Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / or greater plywood , or wood plank. Product Control No.: 94- 0401.01 Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System C Manufacturer: Margon S.A Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: BRAND NAME: GENERIC PLACEMENT PROFILE: DETAIL # Telha Lusa Spanish "S" #2 All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. np O • �� L4!tf1 • Gil Diamond, P.E. Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 32 " or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System D Manufacturer: Entegra Rooftile Corporation Underlayment: Any approved underlayment listed in the Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: BRAND NAME: Estate "S" Skandia Flat GENERIC PROFILE: Spanish "S" Large Flat Product Control No.: 94 0401.01 PLACEMENT DETAIL # # 2 #4 All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. uV� Y1,e�G Gil V4M- mond, P.E. BRAND NAME: • GENERIC PROFILE: PLACEMENT DETAIL # Barrel _ Two-piece Barrel #1 Spanish "S" Spanish "S" #2 9" Flat Tile Small Flat #5 Product Control No.: 94- 0401.01 Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum " / or greater plywood , or wood plank. Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System E Manufacturer: Pioneer Concrete Roof Tile. Inc. Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. ( LOTZ tiil Diamond, P.E. BRAND NAME: GENERIC PROFILE: PLACEMENT DETAIL # Cedeska Barrel Two- piece Barrel #1 Altusa Barrel Two -piece Barrel #1 Altusa "S" Spanish "S" #2 F.R. Borja Barrel Two -Piece Barrel #1 F.R. Borja "S" Spanish "S" #2 Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 32 " or greater plywood , or wood plank. Product Control No.: 94- 0401.01 Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance withDade County Protocol PA 120 as detailed in the South Florida Building Code. System F Manufacturer: Almar USA Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. 9 �cl?J g ilf Gi iamond, P.E. BRAND NAME: GENERIC PROFILE: PLACEMENT DETAIL # Espana "S" - Spanish "S" #2 Capri Double Roll #3 Shake / Slate Large Flat #4 Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 32 " or greater plywood , or wood plank. Product Control No.: 94- 0401.01 Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System F Manufacturer: Lifetile Underlayment: Any approved underlayment listed in the 'Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: Comments: All tile shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Dade County Protocol PA 120). All 'Comments and General Limitations' noted in the Prepared Roofing Product Control Approval shall apply. io O.CL+0. 9 Gil P.E. BRAND NAME: GENERIC PROFILE: PLACEMENT DETAIL # Spanish "S" Spanish "S" #2 Double Roll #3 Flat Shake , Slate Small Flat #5 • Deck Type 1: Wood, non - insulated, new construction Deck Description: Minimum 19 / 2 " or greater plywood , or wood plank. Product Control No.:94- 0401.01 Slope Range: 2 ":12" to 7 ":12" > 7 ":12" shall be bonded and nailed in compliance with Dade County Protocol PA 120 as detailed in the South Florida Building Code. System G Manufacturer: Duntile Underlayment: Any approved underlayment listed in the Products by Other' section of this approval. All underlayments shall be installed in compliance with the South Florida Building Code as detailed in Protocol PA 120. Adhesive Placement: 11 D'WlY104 Gil Diamond, P.E. Component Application: Product Control No.: _94- 0401.01 1. Polypro® AH160 tile adhesive shall only be applied over an underlayment installed in compliance with application instructions detailed in its Component Approval.. Underlayment shall be any underlayments or underlayment systems listed as approved in Dade County Protocol PA 101. 2. Adhesive application shall be in accordance with the instructions provided in this Component Approval, the manufacturer may provide additional instructions subsequent to this approval date which shall prevail. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc.. 3. Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.10 to 0.13 pounds per tile as determined at calibration. No other settings shall be approved without revision of this Component Approval. 4. Adhesive shall be dispensed in a 2" x 10" pad at time of application. The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance with the 'Placement Details' provided in this Component Approval. Each generic tile profile requires a specific placement. (see 'Placement Detail Number' listed under each approved 'System'.) A tile manufacturer may test a tile system in compliance with PA 101 and add an additional detail without incurring an additional revision cost. 5. Adhere tik' directly in freshly applied adhesive. Tile must be set within 31/2 minutes after foam has been dispensed. 6. Adhesive shall be placed to create contact with 3 tiles, as outlined in the 'Placement Detail' for each tile profile. ail Diamond, P.E. Comment and Limitations: Product Control No.: 94- 0401.01 1. Tile must be applied within 3'/2 minutes of the application of Polypro® AH160 adhesive. 2. Polypro® AH160 adhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. 3. Refer to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the Placement Details' included with this Component Approval. 4. Refer to Prepared Roofing Assembly Product Control Approvals for system approvals with this Component. 5. Refer to the Prepared Roof System Assembly for fire rating. 6. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 7. Polypro® AHI60 shall not be exposed permanently to sunlight. 8. Polypro® AH160 shall be applied with Foampro RTF1000 dispensing equipment only. (See Detail 'A' attached.) 9. Field uplift testing shall be performed, in compliance with the test procedure set forth in Dade Couniy Protocol PA 106. Testing shall be performed not prior to 30 days after installation by a Dace Couniy approved laboratory in compliance with the test criteria established in Section 3402.2 of tile South Florida Building Code. 13 Ggamond, P.E. ACTIVATOR ACCEPTANCE NO.: 94- 0401.01 APPROVED : 05/09/94 EXPIRES : 05/09/97 PAGE 1 of 2 RED NITROGEN -BLUE NITROGEN HOSE / HOSE RESIN \- NITROGEN CYLINDER • NITROGEN REGULATOR ASSEMBLY AIR COMPRESSOR 7 BLUE PRODUCT HOSE RED PRODUCT HOSE 12V POWER SUPPLY FOR TIMER 110V AC SUPPLY Foampro RTF1000 Dispenser SCALE: NONE Polyfoam Products, Inc. Component Approval DETAIL A DATE: 5/2/94 APPROVED BY: DRAWN BY: TEF REVISED: 10101010 . Ago MAN Foampro g AIR SUPPLY 0.0 so 999.9 seconds NOTE: SEQUENCE TIMER MOUNTS ON MATERIAL HOSE (NOT ILLUSTRATED) ACCEPTANCE NO.: 94- 0401.01 APPROVED : 05/09/94 EXPIRES : 05/09/97 PAGE 2 of 2 7 SELECTOR SWITCH AUTOMATIC MIX AIR DISPENSING ON /OFF MANUAL DISPENSING ■ SEQUENCE MIX AIR TIMER SUPPLY • 12V TRIGGER CONNECTION 7 - MIX AIR VOLUME CONTROL AIR CYLINDER 1 =i - l'amr �, 1 TRIGGER Foampro RTF1000 Dispenser SCALE: NONE APPROVED BY: DATE: 5/2/94 Polyfoarn Products, Inc. Component Approval L MIX CARTRIDGE MIX AIR MIX TUBE DRAWN BY: TEF REVISED: DrTAIL A • C PAN WEEPHOLE ACCEPTANCE NO.: 94- 0401.01 APPROVED :05/09/94 EXPIRES : 05/09/97 COVER 1 X4 ON EDGE r". MORtAR BEO - FOR COVER TILE METAL EAYE DRIP mortar ea',c closure cctional FASCIA BOARD pair.:. -up mortar 1) Foam Placement for Two-Piece Barrel The 2" x 10 "' Foam Pad When applied \- NAIL FIRST PAN 1-(E' (wi -IEN ADDITIONAL NAILING IS REQUIRE( BY COOS) 2" X 10" ?oam ?ac' ashen applied NAIL COVER HERE (VMEN REQUIRED) ACCEPTANCE NO.: 94- 0401.01 APPROVED :05/09/94 EXPIRES FASCIA BOARD (EPOM). PREFABRICATED CLOSURE NAILED THROUGH PLASTIC NTO APPROVED ADHESIVE :05/09/97 9Oy MINERAL SURFACE ROOFING FELT NAIL HERE Tr.RCUGH PLASTIC RGCF CEMENT (WHEN AOOIiICNAL NA IS RECUIREO BY CCCE 2" x ) 0" :oam Pad whet: applied Y/EEPHOLE 2) Foam Placement Spanish 'S" Tile MEACLAP BARGE 80AF SECURE . Y411 CCRROSIOX RES:STAN T NAILS Seal r.t or POINT-UP ' MORTAR TO MTH SURFACE ROLLED RAKE t%.. (SPANISH S' CU 7S) ) ACCEPTANCE NO.: 94- 0401.01 APPROVED : 05/09/94 EXPIRES : 05/09/97 FASCIA BOARD 3) Foam Placement Double Roll Tile 90, MINERAL SURFACE ROOFING FELT 2" x 10" Foam Pad When applied NAIL TriROUCH PLASTIC ROOF CEMENT (WHEN ADDITIONAL NAILING IS REQUIRED BY CODE) BARGE BOARD ACCEPTANCE NO.: 94- 0401.01 APPROVED : 05/09/94 EXPIRES : 05/09/97 FASCIA BOARD A }FETAL EAR/£ DRIP 4) Foam Placement Large Flat Tile 2" x 10" Foam Pad When app lied NOTE: FOAM CONTACT 1S MADE W1TH 3 TILES. 1. THE HEAD OF ONE T1LE 2. THE UNOERL.00K SIOE OF A SECOND TILE . THE UNDERSIDE OF THE TILE EEING SET NAIL THROUGH PLASTIC ROOF CEMENT (WHEN A00I110NAL NAILING IS REQUIRED SY CCOE) BARGE BOARD POINTED -UP MORTAR OED (WHEN USING NO RAKE FIXTURES -- FLA ► TILE ONLY) SAW - CUT HALF TILE • ACCEPTANCE NO.: 94- 0401.01 APPROVED : 05/09/94 EXPIRES : 05/09/97 NOTE: FOAM SHALL NOT REACH ONTO THE COURSE OR HEAD HO UNOERLOCK R PREVIOUS LOCKOF ADJACENT TILE. 2" x 10" ?cam - Pad .•:: applied I•:L:AOL A.P 4 W I TI l 1 . i r ktEr L CAVE DRIP THICKBUTT 71LE NOTE: FOAM CONTACT IS MAOE WITH 3 'TILES FASCIA BOARO 5) Foam Placement Small Fiat Tile 1. THE HEAO OF ONE 71LE 7. THE UNOERLOCK SIDE 0 A SECOND TILE — 3. THE UNOERSIDE OF THE TILE BEINC SET NAIL HERE THRCVCI. PLAST ROOF CEMENT ( #NEN RECUIREC BY COOE) BARGE BOARD SAWCUT HALF TILE POINTED -UP MORTAR .9E0 I YoD C}A?:!1 fi t� F, T o oE 5 5 1 0 " ) / . e" 3 12:0 % Lo r f7—/ 6u7 z.13 8 / N E 8 Z9 0 TOT Cit6c l o' o -= $/Q !T �Z` = Tt � � 4- 7o 1/ y. 48-'4 2 i 1. 1 a ts.. 25'4" . 2 3,x`7 -Jo ` 0,5 0 )/. P.coy - 384/2_ 6Z Li Q t _T E _. 3 3 :N? 804 CERTIFICATE OF OCCUPANCY MIAMI SHORES VILLAGE, FLORIDA BUILDING DIVISION Miami Shores Village, Fla , Owner, Agent or Tenant of Buildin Lot 'Block— Subdivisio Street Address Approved use by occupancy Remarks • This Certificate of Occupancy is issued to th above named for building at above named location only upo the express provision that the applicant will abide by and comply with all conditions of Ord' nces Nos. 92, 93, 94 and 97, known as the Zoning, Electrical, Plumbing and Building Ordin nc of Miami Shores Village pertaining to the erection, construction, alteration or remodelin ff buildingcbr st ;4ctures. 4 BUILDING Test Location Uplift Pull Test P or F Test Location Uplift Pull Test (P or F) _ Test Location Uplift Pull Test (P or F) 1 26 27 / L1 51 52 2 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 60 10 35 11 36 61 12 2 37 62 13 38 63 14 39 64 15 40 65 16 41 66 17 42 67 MI 18 c1-4 /2/4 55 43 44 68 69 19 20 45 70 21 46 71 22 47 72 23 48 73 24 49 74 25 50 75 Owner's Name: ' i i / ° ^ Permit #• a2 ( � p Job Address' Si / • ( � Al// 1 / 14 / S/ .S Roofing Contractor /` L) R J 1) A g ()cc Type of Tile: /4 1.flJfA 1 f° " Approximate Roof Height* l•S feet Type of Access to Roof: Scaffolds Approximate Square Footage of Roof* / 7 60 ft 2 Required Testin Force: lbs. Testing Equipment: Date Tested* 9 2-1 — 9 S IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS REP C P.E. Du Quesne & Associates, Inc. Consulting Engineers Environmental • Testing Laborator Buildin ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 SUBMIrTE B Du Quesne, P.E. gineer 4513 Du Quesne & Associates, Inc. E.B. license #C005245 Lab Certification #94- 0318.01 815 N.W. 57th Avenue • Suite 428 • SITE SPECIFIC INFORMATION TEST RESULTS P - PASS, F - FAIL Ladder Other Chatillion DFIS 100 SKETCH OF ROOF IN BACK Date Installed* 8 - Roof Pitch* No 95749 Civil • Structural Inspection Services Miami, Florida 33126 • Telephone: (305) 264 -1425 • Fax: (305) 261 -8863 $KETCH OF ROOF JOB SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE SCALE NOTES: 11 0P Al 1111 w 111111111111 INN ; : 1111141111111111 11 FORMIIMMIN 1 .. . �. 1•11...._1 ■■•w111■1111M►�M■■RI• 2..r 1• IMILEINAILVOINIIIIIIIMENEVII REM. 1 111M11 IIIM.. •• y# 111111•1111MIRIV III MEW • /•III•■ • ■■► ._l L SKETCH OF ROOF )OB ye sr, , / -/ / /i 7, > Sr" / A f SHEET NO. 2 CALCULATED BY f f e) DATE CJ - � " S CHECKED BY DATE SCALE OF MIAMI SHORES VILLAGE. FLORIDA BUILDING 0 ELECTRICAL [2] DATR { 195 PERMIT N 9 8558 Contractor's PLUMBING 0 License No ? 4T ROOFING [] [] Work to be performed under this Permit Owner of Building %ir Architect Contractor , or Builder c = ■ 1_-.= • , , Legal Lot II Bl. Description Address of Building .CONTRACTOR OR BUILDER • Signed L Subdi- vision Sq. Ft Value of Project $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work Dill be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the pans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assn responsibilitr f all work done by either, myself, my agent, servant or employee. BY AUTHORITY BY Amt. of Permit $ 7