MECHANICAL/o o r o ti/E PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date / .1 a? /97 Job Address p) J3 4E. 99 T Legal Description Owner/Lessee / Tenant LP / • 1 j / Lu3J aoke Owner's Address 0 253 At E. 99 & / r-ti- Contracting Co. RFFCWi Q u ` /16gr, /AJ Qualifier Tnit 1 P 2EariA J K .S.f' Square Ft. ' )- dP d/dr Condo Pres Signs e of . Notary as to 1N r My Commission xpires: FEES: PERMIT l ��� d/o Condo President Date a 'b' -/ of /3 Date OFFICIAL NO C,':f81 AL DONNIE LEE 1 N "r. NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC610789 MY COMMISSION EXP. AN. 12.2001 RADON C.C.F. APPROVED: Zoning Building Mechanical Tax Folio /4' aft / 0 (i /3Y 5(c0 Historically Designated: Yes No Master Permit # 1 10 7 q� Phone 30 /, -.24C-/ Address l`T Q T . H/AM I LL SS# Phone X305- 9 '/O.3777 State # CAC 4U8 /// Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING CHANICA ROOFING PAVING FENCE SIGN WORK DESCRIPTION /d'3t (1 (1) 3 1 )-'7 � 134 W ; - th to Kw Ileg4 7�, J -1- a // (/) 0 2' 7ri Estimated Cost (value)A1960 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. ire OFFICIAL BO,� NOTARYSEAL 1N;E LEE LANE NOTARY PUBLIC STATE OF FLORIDA MY COMMISSION NO. CC610789 N EXP. AN. 1 2,2001 NOTARY Signatu Hof on acto l I Notary as 1 C /,n a •r or Owner- Builder r My Co • si'∎ n Ex Electrical or Owner - Builder TOTAL DUE / 7 D ate 06 Date Plumbing Engineering 1' (AN APPLICATION FOR BUILDING PERMIT MUST ACCOMFANZ THIS ADDENDUM. IF A MASTER PERMIT HAS BEEN OBTAINED, THE OWNER'S NOTARIZED SiGNATUEE NEED NOT BE PRESENT ON SUBSEQUENT APPLICATIONS.) ITEM 6WI TCH wUTLET5 UNIT FEE LIGHT CURETS RECEPTACLES SERVICE TEIAURY SERVICE SIZE IN AAPS SERV RDA !RAVER CHAN /PRANCE CURETS RANGE TCP OVEN WATER HEATER MOTORS 0- 1 f /MICAS OVER 1- 3 I1 WICKS OVER 3- 5 HP I ITC RS OVER 5- 8 HP MOTORS OVER 8- 10 HP MJTORS OVER 10 25 HP MOTORS OVER 25-100 W MOTORS OVER 100 HP A/C WINDOW GENERATORS TRANSFORSERS GENERATORS TRANSFs GENERATORS TRANSEcPI(RS SPECIAL PIJPOSE OUTLETS COMERCIAL SIGN TIRES S IGH TRANSFORI4RS SIGN T Ih( CLOCK FIXTURES ANTENNA TELEVISION OUTLETS VIOLATION RE INSPECTION IRE STANDPIPE FOUNTAIN LAVATRRT UIRRY TRAY CLOTHES WASTER TILE/RES CENTRAL HEATING PROCESS IUD PRESS PIPING 1HERGROIAO TANKS ABOVE MK) TAMS U.F. PRESSURE VESSELS STEAM BOILERS HOT WATER BOILERS MECHANICAL VENTILATION TRANSPORTING ASSEMBLIES ELEVATORS/ESCALATORS F IRE SPR IP QER SYSTEMS VIOUT IDII RE INSPECTION ITEM BATH T1$ 8 10E1 F DIMS/0 DISPOSAL FLOOR DRAIN GREASE TRAP INTERCEPTOR SHOVER SINK POT/3 COIF. SINK, RESIDENCE SINK, SLOP TEAPQRARY WATER CLOSET URINAL WATER CLOSET INO IRECT WASTES WATER SIPPLY TO: A/C UNIT FIRE SPRINKLER HEATER -NEW INST HEATER- REPLACE (.AWN SPRIN LER -WELL swIIiIMG POOL WATER SERVICE SEVER CONSIECT IONS UT ILITY- SEVER UTILITY- LATER SEPTIC TANK RELAY ORAIIFIELD, 4` PULP E ABA►DON SEPT IC SOAKAGE PIT CU. CATCH BASIN D ISCHARGE MEU DOLESTIC DELL AREA DRAIN ROOF INLET SOLAR WATER /CAM POOL PIPING UN4 SPRINRER SYSTEM GAS RAMS METER SET GALS PIPING PLUMBING 03/07/55 15:24 ' • MSV ADDENDUM TO BUILDING PERMIT APPLICATION ELECTRICAL ITEM SPACE HEATERS 004 MECHANICAL (1 9lo d i)7: nw 11t1IT FEE Stairs sauil *AI 1 8 N' — X l N .--I Beo 200 Rrq CFM CI.oSet 50 CFM 6X6 1W cu °C 10X10 1V x 2 In /8 / In 4 In 12X12_ 10X10 4V 8 In X Bed Rn 6X6 1W 500 CFM 1 OX 4 In x \ O 10X10 4V Bath 50 CFM Floor Garage AHU 10X6 10X6 Floor 8 In 8 In Kitche 300 CFM Foyer Wall \ 10X6 N Bath 50 CFM ACCU 8 In 16 In Retirn O MstrBdrn 225 CFM 10X6 16 In 10X6 / p<1 8 In Floor First Floor Cond units to be strapped to precast concrete stabs Dining Rn 300 CFM 8 In 8 In 8 In Living Rn 500 CFM 10X6 Floor 10X6 Floor 10X6 Floor Secono Floor ACCU 30' to Property line Play Rrn First floor system is a 3 -1/2 ton Carrier Central AC System, 14 SEER with 10 KW Heat Strip, Cond Model #38BRB042, AH Model #FK4CNB006 Refrig lines 3/8 liq, 7/8 suct, Drain line is 3/4 in PVC. Second floor system is a 2 ton Carrier Central AC System, 12 SEER with a 7 KW heat strip. Cond Model #38BRB024, ah Model #FB4ANF024 Ref Lines - 3/8 liq, 3/4 Suct, Drain line 3/4 in PVC. AH located in attic and enclosed with R -19 Ins'd walls, In Q) Cl U Q) £ QJ L QJ S -P O) 0 ▪ W Z 3 c ME,'A VilLILA1,13 APPROVED ZONING STR LICA IPA c p•my...caa PLIKelin ij ROOFING ;I.9G. OFF!Ta SUBJEC7 T CO.?.7t.If;.; 17 f !* P ; COUNTY rug stfoREs .r.: ( l'ON.3!!3!! lTlES rCi: <ACCURACY Of rpj COMPLIANCE IrhTil »E FOLT! COOS 1 A MIAMI SHCAES VILLAGE IS TP.E ARCilITECT, EtilL.GER 8 Si CONTRACTORS it?E CP./;r ;CiD Mill THE ilf' 0: la BUILDING REGULATIONS rillETHER OR NOT SPECIF/CALLY INDIC/111G tiERL:11 1 I Lennox Objective Guide 1 :o Installation Conoar').son : '< ... A X A A * * * * A X * k X k * * * * * * * * * * * * k fr * * * * * * *!: * is y * * * * * A * !; * *'l• * h * a::l• * * X * X k * A k AFFORDABLE: AIR . HEAT, INC.. 516 N. E:. 190 STREET MIAMI, FL. :33179 (305) 940 -0777 . :. : A : N: A YI: A: x * * * X * * * * W. 3; : is * * * * * * * is * v: ti: a+: A : * +: fit: k * is at• * * * * * +: * ;r. W W.A*:d v a. :a. a : 02/05/97 LOGIC 1000 RESIDENTIAL. LOADS ANALYSIS PAGE WII_I_F' :NBOR( PREPARED FOR: MIAMI SHORES VILLAGE BUILDING DEPT. PREPARED BY AFFORDABLE AIR & HEAT.. INc. DESIGN . TEMPERATURE S (DEGREES F) WINTER INSIDE 72 WINTER OUTSIDE 47 SUMMER INSIDE 75 SUMMER OUTS :[DE. 90 DAILY TEMPERATURE: RANGE: INDICATOR DESIGN GRAINS RELATIVE': HUMIDITY 55 DEGREE :S NORTH LATITUDE 25 SUMMER AIR CHANGES PER HOUR 0.4 WINTER AIR CHANGES PER HOUR 0.4 fiOM - 1 MAIN PART OF HOUSE IN ZONE 1 46 X 36 AREA BTUH E3.l1); SO FT LOSS GATP 14A 8 INCH BLOCK NO INSUL. UNFINISHED 266 3,392 2. 0,'• OVERHANG = 1.0 WINDOW 10 SNGLE RN CLR GLASS METAL. FRM FACING -W 13 520 TINT-REFLECTIVE SHADING- DRAPES OR BLINDS SHADING COEFFICIENT -.: 1 REVEAL ::_ 1.0 t. J.NOOW 1C SNGLE PN CLR GLASS METAL. FRM FACING -W 54 J,559 �,•. TINT - TINTED SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL. = 1.0 H:1':NOOW 1_C SNGLE RN CLR GLASS METAL FRM FACING -W 9 260 r, t , TINT - REFLECTIVE SHADING - DRAPES OR BLINDS SHADING COEFFICIENT == 1 REVEAL. = 1..0 10D SOLID CORE 21 242 14 14A 8 INCH BLOCK NO :[NSUL. UNFINISHED 224 2, 856 1,74 OVERHANG = 1.0 .; (NOW 1C SNGLE RN CLR GLASS METAL. FRM FACING -S 64 1,348 9, TINT - REFLECTIVE SHADING - DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 14A 8 INCH BLOCK NO INSUL. UNFINISHED 97 1,237 OVERHANG = 1.0 ',NOON 1C SNGLE RN CLR GLASS METAL FRM FACING -E 45 1,299 , :l TINT - TINTED SHADING - DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 02/05/97 TOTAL. FOR ROOM 1 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE WILLENBC)RG 13,248 CU FT 1,656 SENSIBLE 'LATENT AREA BTUH EITUH SO FT LOSS GAIN WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING -E 90 2,599 4,309 TINT - TINTED SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING -E 136 3,927 6,482 TINT- TINTED SHADING- DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL.. = 1.0 WALL 14A 8 INCH BLOCK NO INSUL UNFINISHED 174 2,219 1,358 OVERHANG = 1.0 DOOR 8C SLDNG DR, 1 PN CLR GLASS METAL F FACING -N 21 606 231 TINT- TINTED SHADING - DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 DOOR 8C SLDNG DR, 1 PN CLR GLASS METAL F FACING -N 21 606 231 TINT- TINTED SHADING - DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL. = 1.0 WINDOW 1C: SNGLE PN CLR GLASS METAL FRM FACING -N 27 780 432 TINT- TINTED SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL. = 1.0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING -N 45 1,299 720 TINT - TINTED SHADING- DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 CEILING 16G LIGHT R -30 INSULATION 1,656 1,366 1,913 FLOOR 22A NO EDGE INSULATION 164 3,321 0 WINTER INFILTRATION 99 CFM 2,719 SUMMER INFILTRATION 99 CFM SENSIBLE GAIN 1,631 LATENT GAIN 3,697 L PEOPLE 4 SENSIBLE GAIN 1200 LATENT GAIN 920 L APPLIANCES 1200 32,654 31,375 4,617 L ROOM - 2 BEDROOM IN ZONE 1 27 X 18 WALL 14A 8 INCH BLOC,,K NO INSUL. UNFINISHED 216 2,754 1,685 OVERHANG = '1.0 WALL 14A 8 INCH BLOCK NO INSUL UNFINISHED 108 1,377 843 OVERHANG = 1.0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING -W 36 1,0(40 1,924 TINT - PLAIN SHADING- DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL, = 1.0 WALL 14A 8 INCH BLOCK NO INSUL UNFINISHED 183 2,333 1,428 OVERHANG = 1.0 ~ 02/05/97 LOGIC 1000 RESIDENTIAL LOADS ANALYSIS PAGE7J WZLLENBORG AREA BTUH 8TUH SO FT LOSS GAIN DOOR 8C SLDNG DR, 1 PN CLR GLASS METAL F FACING-S 21 606 231 TINT-TINTED SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING-S 12 367 216 TINT-PLAIN SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1'0 WALL 14A 8 INCH BLOCK NO INSUL UNFINISHED ' 126 1,607 983 OVERHANG = 1'0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING-E 6 173 32'? TINT-PLAIN SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1-0 WINDOW 1C SNGLE PN CLR GLASS METAL FRM FACING-E 12 347 65n TINT-PLAIN SHADING-DRAPES OR BLINDS SHADING COEFFICIENT = 1 REVEAL = 1.0 CEILING 16D LIGHT R-19 INSULATION 486 844 902 FLOOR 19A HARDWOOD OR VINYL FLOOR + NO INS 488 1,895 0 WINTER INFILTRATION 16 CFM 429 SUMMER INFILTRATION 16 CFM SENSIBLE GAIN 258 LATENT GAIN 584 L PEOPLE 2 SENSIBLE GAIN / 600 LATENT GAIN 460 L APPLIANCES 1200 TOTAL FOR ROOM 2 STRUCTURE TOTALS = 3,888 CU FT 466 SENSIBLE LATENT 17,136 CU FT. SENSIBLE 'LATENT 2,142 MINIMUM Capacity needed 'is 48,293 btu at 90 d outside and 75 degrees inside Maximum Deaired Cooling Capacity is 55 btu [115% of Total Load) 13,551 11,257 1,064 L 46,205 42,632 5,661 L ~'^ , 7.4==== , 4===limmmm=mramminwwWw WWWWW wm=n=mt=m=======m============= *^****^******w***********w*w**** Version 92'12 ***********^^***********^******^ ^ This Heating and Cooling Load Computation was produced using the procedures ^ and tables of the Air Conditioning Contractors of America's Manual * Seventh Edition. The accuracy of the calculated loads depends upon the ^ * accuracy of the data used and the accuracy of the Manual J load calculation * ^ procedures for the glven conditions. No warranty, either expressed or ^ * implied, is given by Lennox Industries Inc. with respect to the aoouraoy * end/or sufficiency of the information orovidad by this report. ^ **************************.***************^******^***^******^****^**^^*******^**