125 NE 98 St (8)t
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 10-24-00 Job Address 125 N. E. 98 Street Tax Folio
Legal Description Historically Designated: Yes No
Owner/Lessee /Tenant Ron P e 1 h e m Master Permit # 91S
Owner's Address 125 N.E . 9 8 Street Phone 756-0031
Contracting Co. Quality Roofing Contractor, Inc. Address 13800 N.W. 1st Avenue
Qualifier rarlos Arocho SS# Phone 751-0382
State # RC 0 0 5 8 6 2 7 Municipal # Competency # 17889 Ins. Co.
Architect/Engineer Add
Bonding Company — Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTION Tear off old roof to wood deck, tin cap
ByQti'�rAYe MARYLOU HERNANDEZ
�: �•� :.: MY COMMISSION # CC 680474
-0 EXPIRES: October 10, 2001
P,F 6: Bonded Thnr Notary Public Underwriters
Notary as to Own ' and/or Condo President
My Commission Expires:
FEES: PERMIT ,-.2S RADON
C.C.F.
Estimated Cost (valu
galvanized eave drip and valley metals where require , /mop on , itti type 111 asphalt
nne layer of 901b.,ASTM felt, install Spanish S Cla colo ru ti e with polyfoam
adhesive setting.
Square Ft. 1() s q
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER
OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work
will be performed to meet the standards of all laws regulating construction in• this jurisdiction. I understand that separate permits are required for ELECTRICAL
PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constructAbn and zoning. Furth - • ore, I authorize the above -named contractor to do the work stated.
-2,12.0/
Signa e of owner an President Date
felt, install
Signature of Contractor or Owner -B ider Date
`,•*PYe /4,; MARY HERNANDEZ -'...
:1 MY COMMISSION # CC 680474
' a? EXPIRES: October 10, 2001
Bonded Thru Noter/ Public Underwriters
m
Notary as to Contra % or or 0
My Commission Expires:
ITI
2 0
NOTARY BOND ,e,fi
,
TOTAL DUE 2I Z
APPROVED:
Zoning Building �" Electrical
Mechanical Plumbing Structural Engineer
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
1R276!53.3 2001 NAY 30 09:18
PERMIT NO. TAX FOLIO NO.
STATE OF FLORIDA:
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and street address:
2. Description of improvement: Reroof to a new Tile roof .
3. Owner(s) name and address: Ron Pelhem
Interest in property: Owner
Name and address of fee simple titleholder: N/A
4. Contractor's name and address: Quality Roofing Contractor, Inc.
5. Surety:(Payment bond required by owner from contractor, if any)
Name and address: N/A
Amount of bond $ 0 0
6. Lender's name and address: N/A
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7., Florida Statutes,
Name and address: N/A
8. In addition to-himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address: N /A
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
differs t date is - • = cified
Sign . ture of Owner Y
Print Owner's Name / tools? /&L4o, 7 4
Sworn to and subscribed before me this day of
Notary Public
Print Notary's Name
My Commission Expires
NOTICE OF COMMENCEMENT
125 N.E. 98 Street Miami Shores, Florida 33138
13800 N.W. 1st Avenue Miami, Florida 33168
RYLOU HERNANDEZ
• !._ COMMI SSIOn 1 tA, bb0474
ST. EXPIRES: October 10, 2001
,:,,,t Bunited Thru Notary Public Underwriters
i ATE OF FLORIDA, COUNTY OF DADE
I HEREBY CERTIFY that tors rs a 'opy of the
ongmal Piled in this t ace on Osy of
- , ADi 6I
M/ITAIESS y hand and Official Seel.
HARV R UVU\ , CL AX, of Circuit and Cour y Cc :-
W Y_ L' .. ✓ ®.c.
125 N.E. 98 Street
Miami Shores, Florida 33138
, 20 0/ .
Prepared by Carlos Arocho
Quality Roofing Contractor
Address: 1 3 8 0 0 N. W. 1 Avenue
Miami, Florida 33168
Contractor's Name: U.� 1T l t f)p�nc DA., TCt f Job Address:
12s sleet
ROOF CATEGORY
❑ (Low Slope Application) ❑ (Nail -On Tile) U (Morta dhesive Set Tile;
❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other)
ROOF TYPE
❑ New Roof L16 Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance
Flat Roof Area (ft Sloped Roof Area (ft 3 D S Gr . Total (ft2) 3 D se , Master Permit No.
Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7 -88 table 1):
t.
V
Ft.
A
A
V
Fastener Type:
Field:
AT CHMENT
SPACING
Perimeter: ner:
DETAIL 1 & 2
ROOF HEIGHT AND SYSTEM DETAILS
(Draw details as needed) ARE Try ':€!%
GAS 'VENT STACKS'?
YES L_1 gas_:
TYPE—NATURAL 0 LPG X ❑
ROOF PLAN
r
r
r
r
123.01 -78 4199
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
Page -1
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
Ridge etti on7
Deck type:
MEAN HEIGHT ' 31
LOODcl X NC to
Underlayment:
Insulation:
30 ksTM
12"
ROOF SLOP/
D E T A I L 3
SLOPED SYSTEM DESCRIPTION
Fastener type & spacing:
1 ll
r;(1 skat,1c- inc ti))
Cap Sheet: 9 0 / b 1-3i'14
Roof C overing: c s
Drip edge:
" /4/05
(o gibs. corners ekrs
a99eL.
ATTACHMENTS REQUIRED
I) Fire Directory Listing Page
2) Miami -Dade County Product Control
Notice of Acceptance -Cover Sheet
a) Specific System Description
b) Specific System Limitation
c) General Limitations
d) Applicable Detail Drawings
3) Municipal Permit Application
4) Other Component Approvals
co-
,aq ^
(Pmaxl: 92 ,3 x a (Aero dynamic Multiplier): I q ,5X) - M 5,3 s = M Lq,19 PCA: (p ( dO
(Pmax2: f 1 x X (Aerodynes is Multiplier):14 ,00) - M S 35 = M a leS PCA: (o1' -SO
(Pmax3: f X (Aerodyn ) - M 33 = M 11106 PCA: (0(o'SD
TILE CALCULATIONS
a.
APPENDIX "F"
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
As it pertains io this Appendix "F', it is the responsibility of the roofing contractor to provide the owner with the required
roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions
of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum requirements and standards of the indus-
try for roofing system installations. Additionally, the following items should be addressed as part of the agreement between
the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained.
K l. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of providing that the roof-
ing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are
not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance,
that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor.
2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance
with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the
existing roof system.)
1 1 P 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. town-
houses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the
occupants of adjacent units of roofing work to be performed.
lkf_4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof deckin g can be viewed from
below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the under-
side of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance.
t ,f_5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond
(accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the
review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roof-
ing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions
should be corrected.
6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build
up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets)
are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC.
fat 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structur-
al assembly (ihe building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to
consider venting which can result in extending the service life for the roof.
0 .8. The owner may contact the Miami -Dade County Consumer Services Department for further information regarding
the above.
Ow er's /Agent's Signature
123.01.12 PAGE 2 7/99
ri
2 f1 - d/
Date Contractor's Signature
ti
MIAMI -
PRODUCT CONTROL NOTICE OF ACCEPTANCE
Almar (USA), Inc.
6645 NW 77 Ave.
Miami FL 33166 CONTRACTOR ENFORCEMENT SECTION
(305) 375.2966 FAX (305) 375.2908
PRODUCT CONTROL DIVISION
Your application for Product Approval of: (305) 375 -2902 FAX (305) 372.6339
Altusa "S" Tile
under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of
Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade
County Building Code Compliance Office (BCCO) under the conditions specified herein.
This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this
product or material at anytime from a jobsite or manufacturer's plant for quality control testing.
If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend
the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is
determined BCCO that this product or material fails to meet the requirements of the South Florida Building
Code.
The expense of such testing will be incurred by the manufacturer.
Acceptance No.:99- 1102.04 (Revises No.: 97- 0918.02)
Expires:12 /16/2002
MIAMI -DADE COUNTY. FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET. SUITE 1603
MIAMI. FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375.
CONTRACTOR LICENSING SECTION
(305).375.2527 FAX (305) 375-2558
Raul Rodriguez
Chief Product Control Division
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE & PRODUCT REVIEW COMMITTEE
This application for Product Approval has been reviewed by the BCCO and approved by the Building Code
and Product Review Committee to be used in Dade County, Florida under the conditions set forth above.
Approvcd: 12/16/1999
rancisco Quintana, R.A.
Director
1 of 8 Miami -Dade County
. Building Code Compliance Ofti,
InternetmaiLaddress: oostnnasterabuildintcodeonline .com _ HomeoYaee: h 1.1ud: ^ ^••••+ - ^ ^i ^vo
^^.
ALMIAR (USA), INC.
1. SCOPE
This revises a roofing system using Almar 'One Piece S' Clay Roof Tile, as manufactured
Almar (USA), Inc. described in Section 2 of this Notice of Acceptance, designed to comply
with the South Florida Building Code, 1994 Edition for Miami -Dade County. For the
locations where the pressure requirements, as determined by SFBC Chapter 23, do not
exceed the design pressure values obtain by calculations in compliance with RAS 127
using the values listed in section 4 herein. The attachment calculations shall be done as a
moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Anplicant
One Piece 'S' T iiC
Trim Pieces
Product
#30 Felt
#43 Coated Base
Sheet
ACCEPTANCE No.: 99- 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
Category: Prepared Roofing
Sub Category: High Profile Tile
Dimensions
1= 18'A"
w= 10"
'A" thick nominal
I = varies
w = varies
varying thickness
Dimensions
N/A
N/A
Test
Specifications
PA 112
PA 112
2.1 Components or products manufactured by others
Test
Specifications
ASTM D 226
type I1
ASTM D 2626
2
Product
Description
High profile clay roof tile. For direct deck or
batten nail -on, mortar set or adhesive set
applications.
Accessory trim, clay roof pieces for use at hips,
rakes, ridges and valley terminations.
Manufactured for each tile profile.
Product
Description
Saturated organic felt to
be used as a nailed
anchor sheet.
Saturated and coated
organic base sheet for
single or double ply
underlay
d ooPPIc - " -
Manufacturcr
generic
;eneric
Frank Zuloaga, RRC
Rooting Product Control Examiner
r
t
ALMIAR (USA), INC.
Tile Nails
Product
Mineral Surface
Cap Sheet
Rainproof II
Ice and Water
Shield
Wood Battens
Tile Screws
Roof Tile Mortar
( "TileTiteT"' ")
NOTICE OF ACCEPTANCE:
Test
Dimensions Specifications
N/A
30" x 75' roll
36" x 75' roll
or
60" x 75' roll
36 "x75'roll
vertical
min. I" x 4"
horizontal
• min. l" x 4" for use
with vertical battens or
min. 1" x 2" for use
alone
Min. 10d x 3"
#8 x 2'Y" long
0.335" head dia.
0.131" shank dia.
0.175" sctrew thread
diameter
N/A
ASTM D 249
PA 104
Wood Preservers Salt pressure treated or
Institute LP - 2 decay resistant lumber
battens
PA 114
Appendix E
PA 114
Appendix E
PA 123
ACCEPTANCE No.: 99- 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
STANDARD CONDITIONS
Product
Description
Mineral surfaced asphalt
roll roofing for use as a
top ply in a double ply
underlayment system.
Single ply, nail -on
underlayment with 2"
self - adhering top edge.
PA 103 Self - adhering
underlayment for use as
a top ply in a two ply
underlayment system
with Approved #30 �r
#43 as the base layer.
Corrosion resistant,
smooth, screw or annular
ring shank nail.
Corrosion resistand coated,
square drive, galvanized,
coarse thread wood screw
Prepared mortar mix
designed for mortar set
roof tile applications.
Manufacturer
generic
Protect -O -Wrap,
Inc.
with current NOA
W.R. Grace Co.
with current NOA
generic
generic
generic
Bermuda Roof
Company, Inc.
(with current
NOA)
Frank uloaga, RRC
Roofing Product Control Examiner
ALMAR (USA), INC.
Product
•
Quickcrete Roof
Tile Mortar
Roof Tile
Adhesive
( "Polypro®
AH 160 ")
Tile -Bond
3. LIMITATIONS
ACCEPTANCE No.: 99- 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTAN E: STANDARD C NDITIONS
Test Product
Dimensions Specifications Description
Manufacturer
N/A • PA 123 Prepared mortar mix
Quickrete Mortar
designed for mortar set (with current
roof tile applications. NOA)
N/A See PCA Two component Polyfoam
polyurethane adhesive y
Products, Inc.
designed for adhesive set (with current
roof tile applications. NOA)
Factory premixed See PCA Single component Flexible Products
canisters polyurethane foam roof (with current
tile adhesive NOA)
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be
performed in accordance with RAS 106.
3 .3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory
to perform quarterly test in accordance with PA 112, appendix `A'. Such testing
shall be submitted to the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing
Applications Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to
the roof slope unless stated otherwise by the underlayment material manufacturers
published literature.
This acceptance is for wood deck applications. Minimum deck requirements shall
be in compliance with chapter 29 of the SFBC.
3.7 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Almar `One Piece S' Clay Roof Tile and its components shall be installed in strict
compliance with Miami Dade County Roofing Application Standard RAS 118, RAS
119, and RAS 120.
Frank Zuloaga, RRC
Roofing Product Control Examiner
Table 3: Attachment Resistance Expressed as a Moment - M (ft -Ibf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
One Piece 'S'
Tile
•
2 -10d Ring Shank Nails
28.6
41.2
19.4
1 -10d Smooth or Screw
Shank Nail
5.1
6.8
2.8
2 -10d Smooth or Screw
Shank Nails
6.9
9.2
7.3
1 . #8 Screw
28.7
28.7
N/A
2 . #8 Screws
58.2
58.2
26.8
1 -10d Smooth or Screw
Shank Nail (Field Clip)
23.1
23.1
19.0:
1 -10d Smooth or Screw
Shank Nail (Eave Clip)
29.3
29.3
24.0
2 -10d Smooth or Screw
Shank Nails (Field Clip)
27.6
27.6
38.6
2 -10d Smooth or Screw
Shank Nails (Eave Clip)
38.1
38.1
41.8
2 -10d Ring Shank Nails'
33.1
48.1
45.2
I Installation with a-4" tile headlap and fasterners are located a min. of 2W from head of tile.
Table 2: Restoring Moments due to Gravity - M (ft -Ibf
Tile
Profile
3 ":12"
or Tess
4 ":12"
5 ":12"
6 "•12"
7 ":12"
greater
Battens
or
Direct
Deck
One Piece 'S'
Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
4.47
5.35
4.40
5.27
4.31
5.16
4.20
5.03
4.08
4.89
ALMAR (USA), INC.
ACCEPTANCE No.: 99 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
4.2 Data For Attachment Calculations
5
Frank Zuloaga, RRC
Roofing Product Control Examiner
Table 1: Aerodynamic Multipliers - X, (f e)
Tile
X (ft)
X (ft')
Profile
Batten Application
Direct Deck Application
One Piece 'S' Tile
0.253
0.274
ALMAR (USA), INC.
ACCEPTANCE No.: 99 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
4.2 Data For Attachment Calculations
5
Frank Zuloaga, RRC
Roofing Product Control Examiner
ALNIAR (USA), INC.
NOTICE OF ACCEPTANCE:
STANDARD CONDITIONS
Table 4: Attachment Resistance Expressed as a Moment M, (ft -Ibf)
Tile
for Two Pa Adhesive Set Systems
Tile Application
Profile
One Piece 'S'
Tile
2 See manufactures com•onent a•proval for installation requirements.
3 Flexible Products Company TileSond Average weight per patty 10.7 grams.
Pol foam Product, Inc. Avera• a wei ht per patt 8 . rams.
Lar.e padd
Medium padd
Tile
Profile
One Piece 'S' Tile
Adhesive
•
Pol foam Pol ProTM
Minimum Attachment
Resistance
66.5'
38.7
Table 4A: Attachment Resistance Expressed as a Moment - M, (ft -Ibf)
Tile
Profile
One Piece 'S' Tile
for Single Patty Adhesive Set Systems
Tile Application
Pol foam Pol Pro TM
lacement of 63.rams of PoI
placement of 24. rams of PoI
Pro*".
Table 4B: Attachment Resistance Expressed as a Moment
for Mortar Set Systems
Tile
Application
Mortar Set'
ACCEPTANCE No.: 99- 1102.0-4
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
Minimum Attachment
Resistance
29.3
- M1 (ft -Ibf)
Attachment
Resistance
24.50
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo,
or following statement: "Miami -Dade County Product Control Approved".
PP d"
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the followin :
6.1.1 This Notice of Acceptance. g
6.1.2 Any• other documents required by the Building Official or the South Florida
Building Code (SFBC) in order to property evaluate the installation of this system.
Frank Zuloaga, RRC
Roofing Product Control Examiner
ALMAR (USA), INC.
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
PROFILE DRAWINGS
ONE PIECE `S' CLAY ROOF TILE
7
ACCEPTANCE No.: 99- 1102.04
Frank Zuloaga, RRC
Roofing Product Control Examiner
ALMAR (USA), INC.
ACCEPTANCE No.: 99- 1102.04
APPROVED :December 16, 1999
EXPIRES :December 16, 2002
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been
filed and the original submitted documents, including test - supporting data, engineering documents,
are no older than eight (8) years.
2. Any and all approved products shall be permanently labeled with the manufacturer's name, city,
state, and the following statement: "Miami -Dade County Product Control Approval ", or as
specifically stated in the specific conditions of this Acceptance.
3. Renewals of Acceptance will not be considered if:
a. There has been a change in the South Florida Building Code affecting the evaluation of this
product and the product is not in compliance with the code changes.
b. The product is no longer the same product (identical) as the one originally approved.
c. If the Acceptance holder has not complied with all the requirements of this acceptance,
including the correct installation of the product.
d. The engineer who originally prepared, signed and sealed the required documentation initially
submitted, is no longer practicing the engineering profession.
4 . Any revision or change in the materials, use, and/or manufacture of the product or process shall
automatically be cause for termination of this Acceptance, unless prior written approval has been
requested (through the filing of a revision application with appropriate fee) and granted by this
office.
5. Any of the following shall also be grounds for removal of this Acceptance:
a. Unsatisfactory performance of this product or process.
b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any
other purposes.
6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the
Notice of Acceptance is displayed, then it shall be done in its entirety.
7. A copy of this Acceptance as well as approved drawings and other documents, where it applies,
shall be provided to the user by the manufacturer or its distributors and shall be available for
inspection at the job site at all time. The engineer need not reseal the copies.
8. • Failurs to comply with any section of this AcceptancLi shall be cause for termination and removal
of Acceptance.
9. This Notice of Acceptance consists of pages 1 through 7 and this last page 8.
END OF THIS ACCEPTANC
Fran Zuloaga, RRC
Roofing Product Control Examiner_
Test Location
Uplift Pull
Test (P or F)
Test Location
Uplift Pull
Test (P or F)
Test Location
Uplift Pull
Test (P or F)
Test Location
Uplift Pull
Test (P or F)
1
A-
26
_ : 5E i
51
. .! .0t ►
76
2
-mo w►
27
52
77
3
28
53
78
4
29
54
7q
5
30
55
80
6
31
56
81
7
32
57
82
8
33
58
R3
9
34
59
84
10
35
60
85
11
36
61
86
12
37
62
R7
13
38
63
88
14
39
64
89
15
40
65
90
16
41
66
q1
17
42
67
92
18
43
68
93
19
44
69
94
20
45
70
95
21
46
71
96
22
47
72
97
23
48
73
98
24
49
74
99
25
50
.�
75
100
Approximate Roof Height feet
Type of Access to Roof: Scaffolds
Approximate Square Footage of Roof: 31
0
Required Testing FIrce: _34 lbs.
Date Tested: B Z � O 1
THIS REPORT SUB ED BY:
Civil Engineer:
Lab Certification # 98- 0608.04
P.E.
State of FL Certificate Authorization # 4100
U.S. SOUTH
Engineering & Testing Lab., Inc.
6065 N.W. 167th Street, Suite B -23 • Miami, Florida 33015
Telephone: (305) 558 -2588 • Fax: (305) 362 -4669
ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN
FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE
PROTOCOL PA 106
ft'
SITE SPECIFIC INFORMATION
Owner's Name: 1 A-6 ?mil - / Permit # 4 9 2-
Job Address' 1 Z 5 id 9 S L• m I A. n41 S C4-0 PAS ,F t
Roofing Contractor: t.3 l t `, � bnf t
Type of Tile Ptl�� I G i ( 4 - ( ,(J iic-LkA 6 el- Date Installed
Roof Pitch
✓Ladder
Testing Equipment: Chatillion 100
TEST RESULTS
P = PASS, F = FAIL
Other
Project
No
81151
3 :12
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT
QUALITY CONTROL TEST.
1419
SKETCH OF ROOF
JOB ( 2 ' i .
SHEET NO ^^ "2- OF
CONTRACTOR 1:k li � l A t; y 'co !
1, c t .� l
CHECKED BY DATE
SCALE
■■■■■■■■ERIN■■■■[M■RI■r7■
■■■■E■ ■■■MEME : % ■■!■E■'■
■■■■■■ ■ ■1■\`■■■PAC /NIEN■■
■■■■■■ ■■ NEMMMJ■■�EN■■
IIIIIIiUIflhI
iiiuiiiuiiiiiiiiirii
........
........
........
111111
ENENEMMEN
••••••tr P rhi
NOTES'