Loading...
125 NE 98 St (7)Joint 2 Joint 2 Joint 1 3 Design for Hip 11 Set 5' -0" from end wall 7' - 0' Joint 10 Joint 10 Joint 1 Hip 11 - Two MemberstRequired - Spike together with 16d nails at 12" o.e. Jolla 5 Joint 4 Joint 7 Joint 8 4fnt 9 J 4 Joint 12 Joint 4 Joint 12 Joint 11 Joint 16 1 1 Joint 2 Joint 15 Joint 17 Joint 2 2x4 Joint 11 2 x 4 E - 24' -9" to 28' -8" x4F -19' -9 "1024' -8" 2x4 A I Joint 2 Joint 11 Joint 14 Design For Hip 1 4 13' -0" spaced 2 -0" o.e. Joint 13 Joint 14 Joint 13 Joint 11' -0" Wedge bloc x From heel Joint 13 5' -0" Design for Hip 12 spaced 2' -0" o.e. 9' -0" Design for Hip 13 spaced 2' -0" o.e. Design for Hip 1 5 spaced 2' -0" o.e. Jo nt 18 or Joint 14 Design for Truss Joint 18 (alt.) spaced 2' -0" o.e. I NOTE: For more complete truss details see file no. K- 120- 28 -3 -55 CAMBER BOTTOM CHORD OF TRUSS AND HIP MEMBERS 3/8' AT CENTER 2' -3" Joint Joint Joint 1 NOTE: Delete wedge block and Q-42 wedge block plate on spans below 26' -8' 12 12 Q3 12 3 12 3 4801 b 3 Truss Diagram 4 14625 5 13,1' 'T 190E 381" 5801 a l b 1 =f c 5 28' -0 e 28 '_ 0 . Truss Diagram d d Truss Diagram 1590 4,5 62401i 4 901 275 b � e Truss Diagram b 915" 867 ". 866 r 867 1 d 4845 1,2 1200 715" c 385 a 1 T Truss Diagram 1,2 d ) e 2 885010 770 28' -0" 1 6�C K-120 S A N F O R D T R U S 3/12 SLOPE — 19' - 9rr to 28'8" SPANS 915" 4801 g ..,�h a d 8850 Stress Diagr am 770 5801 Stress Diagram 0 495" 4951 275" h y 42_ Stress Diagram 605" 5060 605 3 12 a1�.11Ofc� p 3 4401 330" 4401 d1 °1 f f 28' -0' 4 990 1 0 4 1362 C 01 440 3 28 r_0. 3740 3801 1901 330 a d 1 Stress Diagram 7151 3851 e I e 1,2 770" Stress Diagram e 720 d 7701 410 410 e 1 01 h e � >�D►� 12 3 �. 28'41" Truss Diagram 9 9 Stress Diagram H-91 Sanford Grl -P -Late 24' -9" to 28' -8" — H -77 Sanford GrI -P -Late 19' -9" to 24' -B° — Q-54 Sanford Grl -P -Late JOINT 4 Q-42 Sanford Gri -P -Late 1/4" JOINT 10 0-30 Sanford Gri- P-Late jQ -42 Sanford Gri -P -Late T -55 nFord Gri -P -Late JOINT 13 1- JOINT 16 0-I8 Sanford Gri -P -Late 0" JOINT 18 (alt.) Butt Joint T -119 Sanford Gri -P -Late 7/8" 1 -1/2" SANFORD GRI- P -LATES SANFORD GRI - PLATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) hot dip galvanized steel, perforated with 1/4' deep triangular teeth to form the gripping sur- face and having position nail holes pierced approx. 2" o.e. copyright POSITION NAILS, driven through each of the position nail ho es, shall be 1 -1/2" long annu- lar ring shank .120 diameter, 9/32" head. HIP SET 1 3-1/4" T -55 Sanford Gr1 -P -Late H -77 Sanford GrI- P-Late JOINT 1-1/2" Q-2 Sanford Grl -P-Late JOINT 2 JOiNT 5 JOINT 8 JOINT 14 JOINT 17 T -55 Sanford Grl -P -Late JOIN18(alt) K -33 Sanford Grt -P -Late 1960 a. carol sanford 1 -1/2" JOINT 3 Q-42 Sanford Gri -P -Late Q-30 Sanford Gri -P-Lale JOINT 6 Butt Joint S-170 Sanford GrI -P -Late JOINT 9 Butt Jornt T -147 Sanford Grt P JOINT 12 2x4 Block utt O nt T -147 Sanford GrI -P -Late JOINT 15 � M Butt Joint 5-133 Sanford Gri- P-Late JOINT 18 Butt Joint S -110 Sanford Gri -P -Late JOINT.18(alt:) 1 - 1/2" i H -77 Sanford Grl -P -Late 2-1/4" LUMBER shall be of a s ructural grade with a minimum m of elasticity of 1,540,000 p.1.1. For A, and 1,760,000 p.s.l. for D, E, and F. Allowable extreme fiber stress in bending shall be 1200 p.s.!. for A, 850 p.s.l. for D, 1500 p.s.l. for E, and 1200 p.s.l. For F. DESIGN FOR TRUSS 8 HIP TRUSSES 19' -9' to 28' -8" Live and dead loads on roof 45 sq. ft. Dead load on ceiling 10 sq. ft. Total design load 55 :q. ft. NOTE: 33-1/3% allowable unit stress increase for short time loading. S S A N F O R D G R I - P -LATE S SANFORD GRI -P- LATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c . (2.225 teeth per square inch) POSITION NAILS, driven through each of the position nail holes, shall be 1 -1/2" long annu- lar ring shank .120 diameter, 9/32" head, as manufactured by Independent Nail Co. or equal LUMBER as marked with allowable unit stresses of c - 1200 p.s.I. Compression parallel to grain f - 1500 p.s.i. Extreme fiber in bending 0 p.s.i. Modulus of Elasticity 2 X 4 CONSTRUCTION FIR c - 660 p.s.i. Compression parallel to grain f - 850 p.s.i. Extreme fiber in bending e - 1,600,000 p.s.l. Modulus of Elasticity AN NOTE: 33 -1/3% allowable unit stress increase for short time loading. IN DADE AND BROWARD COUNTIES, 'SUBSTITUTE No. 1 SOUTHERN PINE OR 1500f INDUSTRIAL FIR WHERE 2 x 4 CONSTRUCTION FIR IS SPECIFIED. T -I 55 Sanford Gri -P -Late 4 ORD 1 Q -54 Sanford Gri -P -Late a ke rn A DESIGN FOR TRUSS - 14' -9" TO 19' -8" SPACED 2' -0" o.c. 524 9 19' -0" Live and dead load on roof 45 sq. ft. Dead load on ceiling 10 sq. ft. 1 STRESS DIAGRAM Total design load 55 sq. ft. Q 18 Sanford Gri -P -Late 12 3 . CAMBER BOTTOM CHORD 1/4" AT CENTER c p y r l g h 1 9 58 a. C011'0 b c 9 a H -63 Sanford Gri -P -Late K -120 T R U S S sanfor S A N F O R D GRI - P -LATE S SANFORD GRI -P- LATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c . (2.225 teeth per square inch) POSITION NAILS, driven through each of the IN DADE AND BROWARD COUNTIES, position nail holes, shall be 1 -1/2" long annu- lar ring shank .120 diometer, 9/32" heod, os SUBSTITUTE No. 1 SOUTHERN PINE OR manufactured by Independent Nail Co. or equal 1 500 f INDUSTRIAL. FIR WHERE 2 x 4 LUMBER, as marked with altowobleunit stresses off � ^T RUC ft ' N FIR IS SPE_,IFIFO. 2 x 4 1 1 SOUTHERN PINE c - 1350 psi Compression parallel to grain. f - 1500 psi Extreme fiber in bending. e - 1,760,000 psi Modulus of Elasticity. 2 x 4 CONSTRUCTION FIR c - 660 psi Compression parallel to groin. f - 850 psi Extreme fiber in bending. e - 1,760,000 psi Modulus of Elasticity S Q -42 Sanford Gri -P -tote x 4 1 1 Southern Pine A N 4 Co x 4 Fir NOTE: 33 -I/3% allowable unit stress increase for short time loading. T -55 Sanford Grl -P -late So 12' Wedge Southern Pine 5' - 11 12 3 Q-42 Sanford Gri -P -late CAMBER BOTTOM CHORD 1/4" AT CENTER 0 R D a H -119 Sonford Gri -P -late c o DESIGN FOR HIP 1 1- 17' 4" SPAN - SET 5' - 0" FROM END WALL I � 9 � 10 /' 615 615/ b c 1 3 (3 .1\ k !\ 17' 6 4" ' Live and dead load on roof 60 sq. ft. Dead load on ceiling 10 sq. ft. 9 470 159 / 3 2 7 rig 7500'T 1 9 59 a. b22 41 6040 /C 6040`T STRESS DIAGRAM Total design load 70 sq. ft. corn b k K -120 TRUSS toe ford its cr 0 d: SANFORD GRI- P -LATES SANFORD GRr- P- IATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c . (2.225 teeth per guars inch) POSITION NAILS, driven through each of the position nail holes, shall be 1 -1/2" long onnv- kw ring shank .120 diameter, 9/32" head, as manufactured by Independent Nail Co. or equal. LUMBER ..as marked with allowable unit stresses of: 2 X 4 1 1 Southern Pine e - 1350 p.s.I. Compression parallel to grain f - 1450.p.5.1. Extreme fiber in bending e 1,760,000 p.s.1. Modulus of Elasticity 2 X 4 Construction Fir c - 660 p. s.1. Compression parallel to grain f -850 ,p. s.1. Extreme fiber in bending s- 1,760,000p.s.i. 'Modulus of Elasticity Q-18 Sanford i_P -Late X 1 t ern ' the SAN T -55 Sanford Gri -P -Late Q-18 Sanford Gri -P -Late NOTE/ 33-1/3% Allowable unit stress increase for short time looding. IN DADE AND HOWARD COUNTIES, t SUBSTITUTE No.1 SOUTHERN PIN E OR 15001. INDUSTRIAL HR WHERE 2 x CONSTRUCTION FIR IS SPECIFIED. 7'-0" CAMBER BOTTOM CHORD 1/4» AT CENTER 12 OR D DESIGN FOR HIP 12 - 17' -4" SPAN - SPACED 2' -0" o. e. 725 725 r a 490' H-63 Sanford Gri -P -Late 17' -4" Live and dead load on roof 60 sq. ft. • Dead rood on ceiling 10 sq. ft. copyright 1,2,3 T STRESS DIAGRAM Total Design Load 70 sq. ft. 490 K -120 T R (.15 S 1959 0. carat sunford a► a N c0 • w S A N F O R D G R i- P -LATE S SANFORD GR1- P- LATES, pressed into eoch side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c . (2.225 teeth per square inch) POSITION NAILS, driven through eoch of the position nail holes, shall be 1 -1/2" long onnu- tar ring shank .120 diameter, 9/32" head, Q -2 Sanford Gri -P -late (2) 16d nails 12 "4 1' -0" CORNER JACK HIP JACK Q-30 Sanford Gri -P -late or Q -9 Sanford Gri -P -lutes 36" 3' -0' CORNER JACK Q -18 Sanford Gri -P -late 1 4, 1C:4-18 Sanford Gri -P -late Regu 1. r Truss 2 u *NOTE: 2 x 4 Rafter is sufficient for all End Jacks; However larger sizes are generally used when the Top Chord of the Trusses is larger. Last Hip Member PEAK DETAIL Even foot span Beveled ; Q -30 Sanford Gri -P -late or Cuts 2) Q -9 Sanford Gri -P -lutes Partial Cat PEAK DETAIL Off foot span 1/8" x 1" Strap Anchor Bent over Top Chord or Jack and iced with 3 - 16d nails. (by Builder) SA NFOR D PLAN OF HIP ROOF CORNER WITH ALL JACKS. SETBACK 5' -0" FROM OUTSIDE WALL. 2 x 4 Ledger Beveled on top. — Tie ledger to Hipll with (4) 16d nails or Sanford Framing Anchor at each Truss- Member in contact with Ledger Strip. (by Builder) H 1 3 Tie End Jack to Hip 1 1 with Sanford Framing Anchor on the top and 2 - 16d nails on the bottom. (by Builder)- at HIP R rd Tie Hip Jack to Hip 1 1 with Sanford Framing Anchor or 3 - 16d nails - Top and Bottom. _(b Builder) H 1 2 c o p y r i g h t 24" ROOF CORNER PLAN 1960 1/8" x 1" Strap Anchor bent over top chord of Jack and nailed with 3 - 16d nails. (by Builder) 12 -�7 Slope of roof. Q -30 Sanford Grl -P -late and 2) Q -2 Sanford Gri -P- lates 60" • 5' -0" END JACKS 2 x 4 Ledger (by Builder) a. K -120 TRUSS carol Overhang to suit. (See Detail) Min.2 x 4 plate (by Builder) sanford 0 tn r 0 SANFORD G R I- P- LATES SANFORD GRI- P- LATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c . (2.225 teeth per square inch) POSITION Is: . "r•,1c, driven through each of the position nail holes, shall be 1 -1/2" long annu- lar ring shank .120 diamets.r, 9/32" head. 2x4 Sub -faci (by Builder) Q-30 Sanford Grip- late _-- L 8d Nails 1/4" clearance 36" to 48" Q-2 Sanford Gri - - e 2x4 or 2x6 Top Chord of Truss TYPICAL Q -9 Sanford Gri - io +e 8d Nails _4 1/4" clearance 1 . 12" to 24" 2x4 , r ��� 2 x 4 treated Ledger, bolted to wall 48" o. c. - Shim Soffit Joist to solid - bearing and attach to Ledger with Sanford Framing Anchor at each Joist. (by Builder) Min. 2 x 4 Plate (by Buil der) TYPICAL 2 x 4 treated Ledger, bolted fo wall 24" O. c. Shim _ Soffit Joist to solid bearing and attach to Ledger with Sanford Framing Anchor at each Joist. (by Builder) DETAIL OF LEVEL SOFFIT OVERHANG, 2 -1/2 /12 PITCH AND OVER Q -9 Sanford Gri -P -late 2x4 or 2x 6 Top - Chord of Truss TYPICAL - ALL OVERHANGS t ^r 2x4 1/4" clearance TYPICAL for concrete tie beams. See P. 217A for truss anchorage detail using stud bearing walls in areas of 20 psf wind load and less. S ANFORD x 48" to 72" Shim to Solid Bearing 2x4 Plate (by Builder TYPICAL x4 Concrete Tie Beam TYPICAL Q-42 Sanford Gri -P -late 2 x 4 Sub -facia . (by Builder) 8d Nails (2) Q -2 Sanford Gri -P -fates Wedge Block Q -18 Sanford Gri -P -late 7 8 d Nails 2 1/4" clearance 24" to 36" Nail with three 16 d Nails, 1/8" x 1" Strap Anchor bent over Top Chord of Truss. TYPICAL Q-2 Sanford Gri -P -late 8 d Nails T Wedge Block - 1/4" clearance Up to 12 "� 1 a. carol sanfor4 K -120 TRUSS copyright 0 e it I Jt fi 31 ; '` c a I. s ' qi f IP,' � _[i f t ti is -, r , it • > >f u (E VALLEY:1tfl4ac -h;$ It i ` ,j CMi h1E VEg I US SP C 1;i EIt 1 1 USS `t It t► it %fiP! " 1 t USS r� pit ► ,i , I t t t f t 11 faiiiRtiti6S . r; ISYG� 1.1k- E `? day ,4` i I1c MA `K� j ... 1 . c.L .# « J rui 1 ..", -, .A:' r:.ws+a.". ...a..a,..'c. • f..,,�.ou t.,.,..di+ �.... d- Fa ��[_�' �.1' V I f- MEMlg(I NoTE TRUSSES MUS•c• N 33EAR ON ANY INTERIOR WALL. % Or . PARTITION UNLESS )ESt 4ED F o SAME: r S A N F O R D G R I- P- L.A T E S SANFORD GRI-P-LATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to form the gripping surface and having position nail holes pierced approx. 2" o.c. (2.225 teeth per square inch) POSITION NAILS, driven through each of the position Mail holes, shall be 11/2" long annular ring shank .120 diorneter, 9/32" head NOTE: In Dade and 8rowar puntlet :,:.1 lurnbee, x . 6 _ Construction Fir SUPPORT FOR GIRDER FRAMING INTO HIP TRUSS '1 - DETAIL NQ. 1171 1/2" I Bolt ; /W & Jar► 8 Joint 9 J� 8 r Jo nt 8 4 B Joint 10 of t8 Jot t 10 2x6 C 2x6 B Joint 17 Joint 1 Joint 15 S Jo Joint 6 A 2x4 Joint 17 Jot t 11 Joint 15 Joint 5 12 2,5t B 12 2 Trusses required - spike together with 16d spikes approximately 1 2.51"" Joint 7 Joint 13 Joint 7 2 x 6 1 x 4 Cont. C 1 x 4 Cont. 2x4 A C 2 x6 c g 12 2.5t omT14 Joint 4 15' -0" 2 4B Joint 3 Joint 3 Joint 16 Joint 3 1 t 12 Joint 16 CAMBER BOTTOM CHORD OF TRUSS & HIP MEMBER 1/2" AT CENTER F 0 R 1 Jo f 4 Joint 18 Design for Hip Joint 4 7-0" 4 6 0 Joint 2 11' -0" T M i e only #1, 15O, 1020 1060 1060 106Df ,20 ed lumtdr b a 1 d e t f P 9 4 0 I '"t Joint 11 1 set 5' -0" from end wall Joint 9' -0" Design or Hip space 24" o.e. Joint 1 Design for Hip 1 3 spaced 24" o.c. Joint 1 Joint 1 i� 1 Design for Hip 1 5 spaced 24" o.c. Joint 1 Design for Hip 6 spaced 2 • o.c. NOTE: For more complete truss details see file no. K- 120- 32- 2.5 -55 Joint 1 Design for truss spaced 24" o.e. 12 - 1..ears Truss Diagram 7000 C 1 12` ►C T a 12 2750/C 1590 12520 f2.5 4 4 19 :e. _ 5 6 3 l0y —• f 7 2520 1 7 k 200G T � 63 495 500 495 6307 Stress ogr am S 5 0 12.5 ■2,5 Truss Diagram 80010 1870 2 5,6 ) 4 84sjstl' 3 .4urr 9150 4951' 6051 12 271 b 1 c d r 2 42.5 a �t� 3 , 1 /1/1� d 2.5 3301 6051 b 0 3 Truss Diagram 1000 /C ) 1 4,5 I. Truss Diagram 385 I b 715 Truss Diagram 2.5 440 b Truss Diagram Truss Diagram K- 120 T R d U 32 -0" 745/T 6600 6600 770 32' -0" 635 6 550 e e 32' -0" . 525 68704 4 1,2 f4,• 660 d 355 6600 1,2 495 825 c 1di 49 32' -(.1" 32' -0" 884 1,2 2.5 12 SLOP 605 1 f 5501 6051 ► 1 • 7590 70] 715 740 63404 41017 1, 2 1965/C 3 3 1 88I0/ '8001 12 480 6470 S S ba kd Stress Diagram 495 275 330 a h 4 3 58 T k Stress Diagram 385 f I" 1 !'1 d 4t0r k _ . Stress Diagram b 440 N n 490010 h Stress Diagram B25/ d, c 4420 4505 8B0i Stress Diagram 480 60 6275 b'o c � 9 Stress Diagram - 26 -9" to 32'- JOINT I 2•4 Block • H -119 Sanford Gri -P -Late T -55 Sanford Gr -P -tats 0-54 Sanford Gri -4 t Q -30 Sanford Gri -P -Lots 21" Sanford Splice; 10-1/2'4 15 Position Nails 0-9 Sanford Gri -P -Late JOINT 4 JOINT 7 JOINT 10 JOINT 13 2 - 0-30 Sanford Gri -P -Laces JOINT 16 4 copyright SANFORD G R I - P -LATE S SANFORD GRI -P- LATES, pressed into each side of TRUSS face, shall be 20 gage (.0359) galvanized steel, perforated with 1/4" deep triangular teeth to Form the gripping surface and having position nail holes pierced approx. 2" 0.6. POSITION NAILS, driven through each of the position nail holes, shall be 1 -1/2° long annu- lar ring shank .120 diameter, 9/32" head, SPANS —HIP JOINT 2 1 -1/2• JOINT 5 T -55 Sanforc iv flfr Gri -P -Late 0-30 Sanford Gri -P -Late T -75 Sanford GrI -P -Late 1960 21" Sanford Splice 17 Position Nails JOINT 8 JOINT I I JOINT 14 9" Sanford Tee Grt -P -Late 8 Position Nails 3-Q -30 Sanford Gri -P -Cates SET JOINT 3 0-54 over 29' -8" 0-42 up to 29' -8" T -75 Sanford G 1 -P -Late JOINT 9 2x4 Block 0-30 S. G ".P. 0-2 Sc sf1rP-Lat 6 x 24 Sanford GrI -P -Late 24 Position Nails Q -30 5. G. P. Add Q-18's JOINT 12 over 29' - 0" 0-18 Sanford Grl -P -lutes 9-147 Sanford Grl -P -late se nfor d JOINT 15 2 -0-30 Sanford Gri -P -Laces JOINT 18 1/4 ". • 0-30 Sanfor. Gri -P -Lc Q -54 Sanford Grl -P -Late LUMBER shall be of a structural grade with a minimum Modulus o�Flasticity of 1,540,000 p.s.l. for B, and 1, 760,000 p.s.l. for A,C, and I) and a minimum allowable extreme fiber stress in bending of 1200 p.s.l. for A, 750 p.s.1. for B, 1500 p.s.i. For C and 850 p.s.l. for D. DESIGN FOR TRUSS & HIP iRUSSES.- 26' -9" to 32' -9" SPAN Live and dead loads on roof - 45 p.s.f. Dead load on ceiling - 10 p.s.f. Total design load - 55 p.s.f. NOTE: 33-1/3% allowable unit stress increase for short time loading. u carol z x N -0 u 0 0 • 2 A- m 2 L