1178 NE 98 St (14)C•I•V•I•L
E•N•G•I•N•E•E•R
Project:
Dear Sirs;
LG ENGINEERING SERVICES, INC.
Consulting Engineers
2020 Northwest 7th Street
Miami, Florida 33125
Tel: (305) 649 -6454
Fax: (305) 541 -3298
Suntech Development, Inc.
P.O. Box 014014
Miami, Florida 33101
TILE UPLIFT TEST
Duvua Residence
1178 Northeast 98 Street
Miami, Florida
Information provided by client:
Permit Number: Not Available
Date Completion: 2000
Roofing Contractor: Suntech Development, Inc.
LG Engineering Services, Inc. Project Number: LG01 -1574
(Testing Laboratory Certificate #00- 0224.07)
Aus?ust 27. 2001
In accordance with your request and authorization, a representative of LG Engineering Services,
Inc. completed the Roof Tile Uplift Test at the above referenced project. This testing was
performed in general accordance with Roofing Application Standard RAS No.106 -- Standard
procedure for field verification of the bonding of mortar or adhesive set tile system and
mechanically attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 5000 square feet, and the mean height of
the roof is less than 30 feet above ground surface. The type of tile used for this project was
reported to be Flat Roof Tile. This tile was reported to have been foamed in place.
At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile
in the perimeter area and one test for every 200 square feet of roof tile in the field area were
tested. Initially the entire area of the roof was examine for loose tile. More than 10% of the roof
tile located in the field area and more than 20% of the roof tile at the roof perimeter and corner
were physically examined.
Based on'our test: results, we conclude that'the irstallaton of the roof the at the' above referen
projectineets the test requirement outlined.in the above mentioned protocol. Attached please find
a copy of our test report for your revtew
LG Engineering Services, Inc. appreciates the opportunity of assisting you in this project. If you
have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfully submitted;
LG Engineering Services, Inc.
oh. mad Sonny' Salleh., P.E.
Project Manager
TILE UPLIFT TEST
Duvua Residence
1178 Northeast 98 Street
Miami, Florida
Report of
TILE UPLIFT TEST
for
Duvua Residence
1178 Northeast 98 Street
Miami, Florida
Project Number: LG01 -1574
Test Nurnber
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
est Load <:(lbf)
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
Test>Status
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
. f Tst Result -- Project Number: LGO1- 1574 e 1
LG Engineering Services, Inc. -- Uplift Test Project g
:Test Number
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
Test Load (lb#)
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
Test: Status
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
Pass
LG Engineering Services, Inc Tile Uplift Test Result -- Project Number: LG01 -1574, Page 2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
N0�'
45'
5
4
46
1
25
24
7
45
A4
42
45
41
y0
40
59
58
y1
yl
56
9
I2
15
14
9
10
II
78'
4 7
22
21
20
29
48
28
49
50
51
52
52 55
55
54
15
16
17
18
APPr?OXIMATh tf511.00A110N
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date y 4 Job Address // 7 5:7- Tax Folio
Legal Description Historically Designated: Yes No
Owner/Lessee / Tenant Spf //-1 Master Permit # � O 1
/ -o /�
Owner's Address // 7 O 3 °r Cd -■
Contracting Co.
Qualifier P / /Gsq/9 rev SS# - - Phone
State # # Competency # Ins. Co.
Architect/Engineer Address
Bonding Company
Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTION �` /Z��� 7 �J -� � � T
_7"
Square Ft. 0/ Estimated Cost (value)
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet'the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
Sign
Notary as to 0
My Commis
f owner or Condo Pr�� Date
# CC 676542 DIM
N A OCT 21. 2004
NCO
APPROVED:
Zoning Building
Mechanical
FEES: PERMIT RADON C.C.F. 6. 60 NOTARY
1-
Signature of Contractor or Owner- Builder
Notary as to C
My Commissi
S
c„ ira MY COMMISSI, rlq CC 745220
y' 9 EXPIRES: May 26, 2002
;'• Bonded Thru Notary Public Underwriters
Electrical
Date
yl t o /9 9
Da
BOND 3 o 0
TOTAL DUE
Plumbing Engineering
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT Nn. TAX FOLIO NO.
C75 d/ d
STATE OF FLORIDA: 99R208586 1999 APR 22 14:27
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is ..provided in this Notice of Commencement.
1. Legal description of property and street address:
2. Description of improvement: '—
3. Owner(s) name and address:
Interest in property: 2�ir
Name and address of fee simple titleholder:
4. Contractor's name and address:
/4"e- / l'� /. -7 7 i ,/ 7 jai
5. Surety:(Payment bond required by own from contractor, if any)
Name and address:
Amount of bond $
// 7
V7/7/
6. Lender's name and address: -
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7., Florida Statutes,
Name and address:
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address:
9. Expiration date of this Notice of Commencemer • the expiration date is 1 year from the date of recording unless a
different date is specified)
1 Owner
s
Print •wners Name
ure
Sworn to and subscribed before me this oay of
Notary Public '"
Print Notary's Name cY )
My Commission Expires:
.A-: 4.2mw. -
ANCHEZ
STATE OF FLORIDA, COUNTY OF DADE
1 HEREBY CERiIFtI\iha' his is a py of Om
al
ti el in this o co on day of
, A O 19
WINE m h :nd a • d Officio: Seal.
HA; V R� IN f , of Cir itond County Cotorfs
By
Prepared by:
Address: ,
— -7/U/
/i
12ao1 -52 2/93
t
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
Contractor's Name: Space Age Roof Tech Job Address• 1178 N.E. 98 Street
ROOF CATEGORY
® (Low Slope Application) ❑ (Nail -On Tile) ® (Mortar- Adhesive Set Tile)
❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other)
4 ROOF TYPE
❑ New Roof R e- roofing ❑ Recovering ❑ Repair ❑ Maintenance
8 '
Flat Roof Area (ft') 400 Sloped Roof Area (ft') 2400 Total (ft 2800 Master Permit No.
Exposure category (per ASCE 7-88): C Building Classification category (per ASCE 7-88 table 1): 1
d
DETAIL 1 & 2
ROOF HEIGHT AND SYSTEM DETAILS
(Draw details as needed)
Ft.
A
v
1- gafglas mineral surface
7 2- gafglas ply 4 with hot
1- gafglas 75# base
tin capped
Deck type : 5 /8" cdx & wood plank
3" x 3" galvanized eave drip
ATTACHMENT ,
1 5/8" tin cap
Fastener Type: with 1 1/4" rs nail
SPACING
9" laps
Field: 12" Perimeter: 6" Corner: 6"
cap sheet with hot asphalt
asphalt ROOF PLAN
r
Rides. %Wades?
N/A
KEA,i =cur 19'
(Pmax1:
D.ektype:
Appendix "E"
UNIFORM ROOFING PERMIT APPLICATION
PROCESS No.
5/8" plywood/wood plank
URdethyment:
3.
it
Roos SLOP!
D E T A I L 3
30# astm felt
N/A
SLOPED SYSTEM DESCRIPTION
Fastener type & ap dng: J 1 1/4" rs nail with 1 5/8" tin cap (9" laps & 12" field)
Cep m 90# astm slate mopped on wih hot asphalt
Roof Covering: Metro Flat cement tile
TECA
Delp edge:
3" x 3" galvanized eave drip
72.3 X X (Aerodynamic Multiplier): 20.97 ) - m 6.97 = M 1 :14.03 PCA: 118.90 OK
(Pma 117.3x X (Aerodynamic Multiplier): 34.02 ) • M 6.97 = M,. PCA:118.90 OK
(Pmax3: 117.3 x ? (Aerodynamic Multiplier): 34.02 ) - M 6.97 = M PCA: 118.90 OK
ATTACHMENTS REQUIRED
1) Fire Directory Listing Page
2) Dade County Product Control
Notice of Acceptance-Cover Sheet
a) Specific System Description
b) Specific System Limitation
c) General Limitations
d) Applicable Detail Drawings
3) Municipal Permit Application
4) Other Component Approvals
JUl_ -09 -96 01:52 PM
APPROVED: 06104MR 1
Intarnei mall address: postwlasler €100dIn9e
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE OFFICE
METRO - DADE FLAGLER BUILDING
140 WEST FLAGLER STREET. SUITE 1603
MIAMI. FLORIDA 33130.1563
(305) 375.2901
FAX (305) 375 -2008
PRODUCT CONTROL DIVISION
(305) 37S -2902
FAX (305) 372 -6339
TROD QT CONTROL NOTICE OF ACCEPTANCE
Metro Roof Tile, Inc.
11501 Northwest 1 17 Way
Medley, FL 33178
Your application for Product Approval of:
Metro Roof Tile, Nail - On, Mortar Set, or Adhesive Set "Concrete Flat" Roofing Tile
under Chapter 8 of the Miami -Dade County Codc governing the use of Alternate Materials and Types
ofConstruction, and completely described in the plans, specifications and calculations as submitted by:
Reiland Technologies, The Center for Applied Engineering, inc. and Testwell Craig
Laboratories & Consultants, Inc.
ha, been recommended for acceptance by the Building Code Compliance Office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 -1 1 and the standard conditions on
page 12.
This approval shall not be valid after the expiration date stated below. The Building Codc Compliance
Office reserves the right to secure this product or material at any time front a jobsite or manufacturer's
plant for quality control testing. If this product or material fails to perform in the approved manner, the
Building Code Compliance Office may revoke, modify, or suspend the use of such product or material
immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is
determined by the Building Code Compliance Office that this product or material fails to meet the
requirements of the South Florida Building Codc.
"Ilse expense of such testing xvil1 be incurred by the manufacturer.
ACCEPTANCE NO.: 98- 0423.09 Renews: 94 1222.14
EXPIRES: 06/04/01
aul Rodrig i CZ
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND CENER L
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Mtiarni -Dade County Building Code
Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida
under the conditions set forth above.
atzzi
Charles Danger, P.E.
Director
Building Codc Compliance Dept.
Miami -Dade County
P. 01
Hontepage: tlttpJ /www.bultdingeodaonline.corr►
JUL -99 -98 92 :24 PM
METRO ROOF TILE INC.
Product
ft, of Tile Adhesive
(PoIyproe A11160)
Dimensions
Test
Specifications
N/A PA HO 0 Adhesive designed
for use in roof tile
applications.
I {urricane Clip & Clips PA 114 Corrosion resistant
Fasteners min. %a" width Appendix E bronze, aluminum,
min. 0.060" thick stainless steel,
galvanized steel or
Clip Fasteners plastic attachment
min. 8d x 1'/." clips for
Page 4 of 12
Product Control No.: -04 3.09
Prod uct
Description
supplemental tilt
attachment. Clips
are installed with
corrosion resistant
roofing nails
compatible with the
clip.
Manufacturer
Polyloam Products,
Inc.
with current PCA
generic
Frank Zuloaga. RRC
Roofing Product Control Examiner
P.92
Tile
Profile
Tile
Application
Attachment
, Resistance
Metro Roof Tile Concrete Flat
Mortar Set
39.00
Adhesive Set
118.90
JUL -09 -98 02:29 P11
METRO ROOF TILE INC.
M Roof
Tile Concrete
Flat
Battens
Direct Deck
1 nail
4.90
9.80
DATA FOR ATTACHMENT
CALCULATIONS
,_ _..___W— Table 1: Aerodynamic Multipliers 1 (ft') — 7
Tile A (ft') X 01 3)
Profile pp
Batten Application Direct Deck Application
Metro Roof Tile Concrete Flat 0.27 0.29
Table 2: Restoring Moments due to Gravity - M -lbf)
Tile 3":12" 4 ":12" 5 ":12" 6 ":12"
Profile
Batten Direct Batten Direct Batten Direct Batten Direct
s Deck s Deck s Deck s Deck
Metro Roof 6.53 6.97 6.43 6.86 6.29 6.71 6.14 6.54
Tile Concrete
Flat
Table 3: Attachment Resistance Expressed as a Moment - M (ft -lbf)
for Nail -On Systems
Tile Tile Approved Approved
Profile Application Nails Screws
2 nails
7.40
18.80
1
screw
Page 10 of 12
2
screws
Product Control No.: 98- 4423.09
Approved
Field Clip
With:
1 nail 2 nails
24.20 34.80
24.30 35.50
7 ":12" or
_ greater
Batten Direct
s Deck
5.97
22.10
19.00
N/A
Approved
Eave Clip
With:
1 nail 12 nails
32.20
31,90
1 Data noted in Table 3 is for instal ation with a 3" the headlap.
2 Approved screws are as noted in the "Trade Names of Products Manufactured By Others'
and 'Profile Drawings' sections of this Approval. Clips an eave tile are not required for this
attachment configuration unless the Required Moment of Resistance exceeds the values
noted above.
Table 4: Attachment Resistance Expressed as a Moment – M, (ft -lbf)
for Mortar or Adhesive Set Systems
Frank Zuloaga, RRC
Roofing Product Control Examiner
P.09
JUL -09 -98 61:54 PM
METRO ROOF TILE INC.
Product
Metro Roof Tile
Concrete fiat
Trim Pieces
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT
Test
Din }cpsions Specifications
1 =16"
w = 10" -
1 -'/." thick
1= varies
w = varies
varying
thickness
PA 112
PA H2
Product
Description
Fiat, interlocking, high pressure
extruded concrete roof tilt
equipped with two nail holes. For
direct deck or battened nail -on,
mortar or adhesive set applications.
Accessory trim, concrete roof
pieces for use at hips, rakes, ridges
and valley terminations.
Manufactured for each the profile.
TRADE NAMES OF PRODUCTS MANUFACTURED OTI{FRS
Test
Product Control No.: 98- 0123.09
Product
AM(, r.r �... ...•
P.02
JUL -09 -99 02:24 PM
3}
• METRO ROOF TILE INC.
product
Roofing Nails
Wood Battens
Tile Nails
Tile Screws
Roof 'I Ti le Mortar
(" rile raterM ")
Roof Tile Mortar
("Quikrcle0 Roof
Tile Mortar ")
Root" file Mortar
( "I3ONSAIA Roof
Tile Mortar Mix ")
Mmensions
min. 1 2 ga. with
3 /8" head
vertical
min. 1" x 4"
horizontal
mitt. 1" x 4" for use
with vertical
battens or
min. 1" x 2" for use
alone
vain. 8d x 2'W' or
min. 10d x 3"
118 x 2W long
0.335" head dia.
0.131" shank dia.
0.175" screw thread
diameter
N/A
N/A
N/A
Test
Smectfications
PA 114
Appendix E
Wood Preservers Salt pressure treated
Institute LP - 2 or decay resistant
lumber battens
PA 114
Appendix E
PA 114
Appendix E
PA 123
I'A 123
PA 123
Page 3 of 12
Product Control No.: 98- 0423.09
Product
llescription
Annular ring shank,
hot dipped, electro
or mechanically
galv. roofing nails
for use in
underlayment
attachment.
Corrosion resistant,
screw or smooth
shank nails.
Corrosion resistant,
coated, square
drive, coarse thread
wood screws
Prepared mortar
mix designed for
mortar set roof till:
applications.
Prepared mortar
mix designed for
mortar set roof tilt
applications.
Prepared mortar
mix designed for
mortar set roof tile
appt icat ions.
Manufacturer
generic
generic
generic
generic
Bermuda Roof
Company, Inc.
with current PCA
Quikrete
Construction
Products
with current PCA
W.R. Bonsai Cu.
with current PCA
Frank Zuloaga, RRC
Roofing Product Control Examiner
P.01
•
JUL -09 -90 02 :23 PM
M}.TRO ROOF TILE INC.
` cstAgenmr
Redland Technologies
Red land Technologies
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
Redland Technologies
Redland Technologies
Redland Technologies
The Center for Applied
Engineering, Inc.
7'cstwelt Craig
Laboratories &
Consultants, Inc.
EVIDENCE SUBMITTED
Test Identifier
7161 -03
Appendix 111
7161 -03
Appendix 111
94 -084
94 -060A
7161 -03
Appendix II
Report Dated
Aug. 1, 1994
P0631 -01
PO402
Project No. 307024
Test 11MDC -73
Lab #:1 A -22
Tech: G. Suarez
Page 5 of 12
Teat Narne/Repnrt
Static Uplift Testing
PA 102
Static Uplift Testing
PA IO2(A)
Static Uplift Testing
PA 101
Static Uplift Testing
PA 101
Window Tunnel Testing
PA 108
(Nail -On)
Wind Tunnel Testing
PA -108
(Nail -On)
Wind Tunnel Testing
PA -108
(Mortar Set)
Withdra%%at Resistance
Testing of smooth vs.
screw shank nails
Wind Driven Rain
PA 100
Physical Properties
PA 112
Product Control No.: 98- 04;3.09
Date
Dec. 1991
Dec, 1991
May 1994
March, 1994
Dec. 1991
Aug. 1994
July 1994
Sept. 1993
Oct. 1994
Sept. 1994
ran - Zuloaga, RRC
Roofing Product Control Examiner
P. 03
JUL -09 -90 02 27 PM
i: .
MI -TRO ROOF TILE INC.
SYSTEMS
(CONTINUED)
SYSTEM D: Mortar or Adhesive Set Application
Deck Typc; Wood, Non- insulated
Deck Description: New construction 19 /32" or gfeater plywood or wood plank,
Slope Range: 2 ":12" to 7 ":12"
Note: System D is only acceptable in this slope range. For slopes in excess
of 7 ":12 ", refer to System C.
Undcrlaymcnt:
Roofing Tile:
Instal{ underlayment system in compliance with Miami -Dade County Roofing
Application Standard PA 120. (See System Limitation W5.)
Install tile in compliance with Miami -Dade County Roofing Application
Standard PA 120, (Sec "Data for Attachment Calculations" included in this
Approval.)
Comtnents: 1. For re-roof applications, 15 /32" plywood is an acceptable substrate.
Page 8 of 12
Frank Zuloaga, RRC
Roofing Product Control Examiner
P.06
Product Control No.: 9S_ 0.123.09
JUL -09 -98 02:20 PM
METRO ROOF TILE INC.
Product Control No.: 9 1?423.09
SYSTEM LIMITAT1ONS
The standard minimum roofpitch for Metro Roof Tile's "Concrete Flat ", flat profile tile shall
comply with Miami-Dade County Roofing Application Standards PA 118 or PA 120, depending on
the method of installation.
2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter
larger than that of the preformed holes in the tile.
3. System installation shall be in compliance with the system specifications outlined in this Product
Control Approval. The method of attachment utilized shall provide sufficient attachment resistance
expressed as a moment to meet or exceed the required moment of resistance determined in
compliance with Miami -Dade County Protocol PA 115 or PA 127. The Metro Roof Tile "Concrete
Flat" tile profile has been tested for both wind characteristics and static uplift performance,
therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be
done as a 'Moment Based System'.
4. For mortar or adhesive set tile applications, a field static uplift test by a Miami -Dade County
accredited testing agency, in compliance with Miami Dade County Protocol PA 106, shalt be
performed.
5. For mortar set tile applications, 30/90 hot mopped underlayment applications may be installed
perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's
published literature.
6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for
identification in the field.
7. Applications for roofing per,nits shall include a completed Section I1 of the Uniforms Building
Permit, a copy of Metro Roof Tile's current specifications and details, a copy of this Product
Control Approval and a copy of the Product Control Approval of any Roofing Component used in
the proposed tile application. Reference shall be made to appropriate data for the required fire
rating.
The applicant shall retain the services of a Mianti -Dade County certified testing Laboratory to
maintain quality control in compliance with the South Florida Building Code and related protocols.
Samples taken shall be in compliance with Miami -Dade County Protocol PA 112, Appendix 'A'.
Page 9 of 12
Frank Zuloaga, RRC
Roofing Product Control Examiner
P.07
16'
16'
10'
METRO ROOF TILE CEMENT FLAT TILE
Page tlof12
Frank Zutoaga, RRC
Roofing Product Control Examiner
_ - •., ,�, i i MUMM n of tuts Acceptance, unless prior written approval has been
requested (through the filing of a revision application with appropriate fee) and granted by this
ofr.ce.
5 Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for salts, advertising or any
other purposes.
6 The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and
f o f o w e d b y t h e expiration date may be displayed i n advertising literature. I f any portion of the
Notice of Acceptance is displayed, then it shall be done in its entirety.
7 A copy of this Acceptance as well as approved drawings and other documents, where it applies,
shall be provided to the user by the manufacturer or its distributors and shall be available for
inspection at the job site at all times. The copies need not be resealed by the engineer.
S • Failure to comply with any section of this Acceptance shall be cause for tent►ination and removal
of Acceptance.
9 This Acceptance contains pages 1 through 14.
END OF THIS ACCEPTANCE
Page 12 of 12
rank Zuloaga, RRC
Roofing Product Control Examiner
1
PRODUCT CONTROL NOTICE OF ACCEPTANCE
BUILDINii CODE COUPUANci C E
METRO-DADE FLAMER RIMING
140 WEST FLAGLER STREET: SDITE1603
MIAMI, F1RORIWi 3313 .1SiS3
. (305).X:94901
FAX (305)
PRODUCT CONTROL DIVISION
(305) 375.2902
FAX (305) 372 -4339
GAF Materiab Corporation
1361 Alps Road
Wayne, NJ 07470
Your application for Product Approval oib
Get F Conventional Built-Up Roof Systems for Wood Decks
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of
Construction, and completely described in the plans, specifications and calculations as submitted by:
Dynatech Engineering, Inc, Factory Mutual Research Corporation. and Underwriters Laboratories, Inc.
has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida
under the specific conditions set forth on pages 2-40 and the standard conditions on page 41.
This approval shall not be valid after the expiration data stated below. The Building Code Compliance Office
reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality
control testing. If this product or material ails to perform in the approved manner, the Building Code Compliance
Office may revoke, modify, or' suspend the use of such product or material immediately. The Building Code
Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance
Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this
product or material fails to meet the requirements of the South Florida Building Code.
The expense of such testing will be incurred by the manufacturer.
Approved: 11104/97
Acceptance No.: 97.0804.21 Revises No.: 95- 1003.03
Expires: 1 1 /04100 Jaul Rodriguez
Product Control Supervisor
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Office and approved by the Building Code Committee to be used in Dade County, Fl oti under the
conditions set forth above. , !!
Charles Danger, P.E.
Director
Building Code Compliance Dept.
Metropolitan Dade County
t?/
Item's mail address: postmasterebuildingeodeonline .com Homapage: ht tpllwww.buiidingeodsonilne•eonr
s.
•
PRODUCT CONTROL NOTICE OF ACCEPTANCE
ROOFING SYSTEM APPROVAL
Applicant:
GAF Materials Corporation Product Control No.: 97 -0804.21
136! Alps Road
Wayne, NJ 07470 Approval Date: November 4,1997
Category: Membrane Roofing System
Sub - Category: Built -up Roofing
Type: Conventional
Sub -Type: Fiberglass
Contact:
William J. Woodring
Director of Technical Services
(973) 628- 4134
Page 2 of 41
Product Coatnoi Na 9 7- 0804.21
. 4.011
•
'irt.l
Expiration Date: November 4, 2000
Zuloaga,
Roofing Product Control Examiner
System Description
GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years,
produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition,
GAF offers two ply modified systems to meet the demands for multi -ply SBS modified specifications.
GAF provides warranted systems over various insulated and non - insulated substrates, copies of which
can be obtained from GAF and can be found in the "GAFGLAS Built -Up Roofing Application and
Specifications" manual published annually.
GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and
Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida
Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material
Directory and the current Factory Mutual Approval Guide.
GAF Materials Corporation products are distributed through a wide network of roofing wholesale
distributors throughout the South Florida area.
For more information on specific roof system constructions, contact the Technical Service Office, located
in Wayne, New Jersey, at 1- 800 - ROOF -41 1.
t'
Insulation Types:
Basalt Wool
Perlite
Polyisocyanurate
Composite Board
Wood Fiberboard
High Density Wood Fiberboard
Rockwool
•
Maximum Design Pressure
Material Design Pressure
Wood -75psf
Maximum Fire Classification
Material Classification
Wood Class'A'
Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck
types. Review system listings for design pressures and the Underwriters Laboratories Roofing
Materials Directory for Fire Classifications.
Roofing Product Control mina
Deck Type 1:
Deck Description:
System Type A(
All General and Syste
Base Sheet:
Ply Sheet:
Cap Sheet:
Surfacing:
Maximum Design
Pressure:
Maximum Fire
Classification:
Maximum Slope:
Specification No.:
Wood, Non - insulated New Construction or Reroof
"/ or greater plywood or wood plank decks
Base sheet mechanically fastened.
m Limitations shall apply.
FGLAS #80 Ultima Base Sheet, GAFGLAS PLY 40, '
G w LY 6®, GAFGLAS FlexPly, GAFGLAS STRATAVENTO
Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 applied to the
deck with approved annular ring shank nails and minimum 1' /." tin caps at a
fastener spacing of 9" o.c. at the lap, 12" o.c. in two rows staggered along the
center line of the sheet in the field.
GL wo o three p of GAF�GLAS® PLY ' .. AFGLAS FlexPly 6 or
ASS PLY 6' p y s - • in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbsisq..
(Optional) One pi
mopping of approved asp
Ibslsq..
• • 1• _
•
of GAFGLAS® Mineral Surfaced Cap Shee
dhered in a full
and at a rate of 20-40
(Required if no cap sheet is used) Install one of the following:
1.GAF WEATHER COAT® Emulsion with an application rate of 3 gal /sq.; or
GAF Premium Fibered Aluminum Roof Coating with an application rate of 1.5
gal /sq..
2. Asphalt flood coat at an application rate of 60 Ibslsq. t 20%: plus gravel or
slag with an application rate of 400 Ibslsq. & 300 lbs.sq., respectively.
-45 psi. (See General Limitation #7)
'A'. See General Limitation #2.
6 ":12 "; See General Limitation #3.
N- B-3-G, N -B-3-C. N- B-3 -M, N- B-4 -G, N- B- 4 -G/P6, N- B-4-M, N- B- 4 -MIP6, N - B-4
N- B.4 -C/P6, N- B-5-C, N- B- 5 -C/PC, N- B-5-G, N- B- 5 -G/P6, N- B -5 -M, N- B- 5 -M/P6
- I _ zer'i Product No: 9T-0110421
Wood Deck System Limitations:
1. Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F')
of 95 lbf or greater as tested in compliance with Merto -Dade County Protocol PA 105: :If F as
tested is below 95 1bi a professional engineer may submit a revised fastener spacing utilizing
the withdrawal resistance value taken from Marto-Dade County Protocol PA 105 and
calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117.
2 All standard insulation panel sizes are acceptable for mechanical attachment. When panels are
applied in hot asphalt, maximum panel size shall be 4' x 4'.
a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of
275 Ibf. as tested in compliance with Merto-Dade County Protocol PA 105 . 8c Roofing
Application Standard PA 117. if the fastener value, as field tested, are below 275 lbf. insulation
attachment shall not be acceptable.
3 A slip sheet is required with Ply 4® Flex Ply' 6 and Ply 6® when used as a mechanically fastened
base or anchor sheet.
4. Y•. Type X gypsum board is acceptable to be installed directly over the wood deck..
•
•
GENERAL LIMITATIONS
All asphalt shall comply with ASTM D 312 type III or type IV requirements, and
approved by applicant.
2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to
current Underwriters Roofing Materials Directory or other fire testing data listed in the
testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 340I.6 of
the South Florida Building Code.
3 Maximum slope range shall vary for each system; consult current Underwriters
Laboratories Roofing Materials Directory and manufacturez's specifications for
compliance with design criteria for each project.
4 An overlay and/or recovery board insulation panel is required on all applications over
closed cell foam insulations when the base sheet is fully mopped. If no recovery board is
used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet
may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.;
or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of
the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation.
Asphalt application of either system shall be at a minimum rate of 12 Ibs./sq. Note:
Spot attached systems shall be limited to a maximum design pressure of -45 psi Where
STRATAVENT Perforated is used over approved isocyanurate foam insulation, the
maximum design pressure is limited to — 60psf.
5 All work shall be performed by a contractor licensed to do roofing work in Metro - Dade
County. Contractor shall be familiar with the details and specifications published by the
manufacturer, and the requirements of the SFBC.
6 The submission of system specifications and details shall accompany the Section II
Building Code Permit. This information is available in the publications listed in the
'System Description' of this Product Control Approval. The submission of these
documents, as well as the proper application and installation of all materials shall be the
sole responsibility of the contractor.
Pages 3S of 4l
uloaga,
Roofing Product Control Examiner
8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination
designs shall conform with Metro -Dade County Roofing Application Standard PA I 1 I
and the wind load requirements of Chapter 23 of the South Florida Building Code.
9 Flashings shall be installed according to the manufacturers standard details, and may be
applied in cold application adhesive, approved asphalt or may be applied in conjunction
with an approved torch applied modified bitumen membrane. Specific details, approved
by the manufacturer, shall be submitted with the Section II Permit Application. All details
shall comply with the provision of the South Florida Building Code.
10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force
(F') value as tested in compliance with Metro-Dade County Protocol PA 105. If the fastener
values as tested are below those listed in the System Limitations, a professional engineer may
submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro -
Dade County Protocol PA 105 test report and calculations that comply with the wind load
requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard
PA 117.
11 Fastener spacing for insulation attachment is based on a Minimum Characteristic Force
(F') value of 275 lbf., as tested in compliance with PA 105. If the fastener value, as field tested,
are below 275 Ibf. insulation attachment shall not be acceptable.
12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance
with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or
bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt
types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South
Florida Building Code.
13 Insulation may be installed in multiple layers. The first layer shall be attached in
compliance with Product Control Approval guidelines. All other layers shall be adhered
in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq., or mechanically attached using the fastening pattern of the top layer. Refer to
manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct
application procedures of insulation panels in approved asphalt or hdhesive, which shall
_ comply with provision of Roofing Application Standard PA 117.
Product Control No: 97 -080421
Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas,
as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener
densities shall be increase for both insulation and base sheet as needed calculated in compliance
with Metro -Dade County Roofing Application Standard PA 117. (When this limitation is
specifically referred within this NOA, General Limitation #20 will not be applicable.)
Roofing Product Control
14 All standard panel sizes are acceptable for mechanical attachment. When applied ul
approved asphalt, panel size shall be-fix 4' maximum. . ...::J .. ° '
15 In re-covery/re-roofing applications, prior to the application, all existing roof surfaces usedras'a • ,�� .:
bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA . fo _ :' .- .
uplift resistance. Test pressures shall be calculated in compliance with the wi : .,
requirements of Chapter 23 of the South Florida Building Code to the design pressure of the too£ ' :.:_
16 in re- roofing applications, moisture content in an existing roof must be in compliance with
Section 3401.10(m), (n) of the South Florida Building Code.
17 Roll good materials shall be stored on end and on a clean, flat and dry surface.
18 If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or
approved adhesives may be used prior to the application of the insulation layer.
19 Consult current Underwriters Laboratories Directory for the appropriate coating for each
roofing assembly to obtain the required fire rating. The assembly shall be installed in
strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for
maximum fire classification.
20 The maximum designed pressure limitation listed shall be applicable to all roof pressure
zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be
permitted for enhanced fastening at enhanced pressure zones (Le. perimeters, extended
corners, and corners). (When this limitation is specifically referred within this NOA,
General Limitation #7 will not be applicable.)
Page 40 of 4 t
Product Control No: 97 -O804i2
u oaga.
Roofing Product Control Examinee
214 ROOF COVERING MATERIALS (TENT)
ROOFING SYSTEMS (TGFU)— Continued
Surfacing "Gurgle* UA.85" Series 1 gaVeq or "Gscoflsx UMW" applied at 1.1/4 gaVaq (12
dry mist.
. 42. Deck: NC Incline: 1/4
Foam: "Poly4so" or "Polvlso Special" with "Polyfoam 261" or "Polyfo.m 303 ", 1 in. min.
Sue Coat: One or two applications "GacatI.x U8- 7060". applied at 1 gaVsq/epplication or 3
applications applied 1 -1/4 gaVsq/apdicetion (16-32 dry mita/.
Surfacing: "Gacoflex UA-65" Series (various colon) applied 1 gaVsq (12 dry mast.
43. Dec1k NC Udine: 1/2
Foam: "Poly4so" or "Polydso Specter with "Polyfoam 251" or "Polyfoanr 303 ", 1 in, min.
Base Coat One or two applications "Gacoflex UB- 7050", applied at 1 gal/aq/applieetion or 3
applications applied 1 -1/4 oaVsq/applicadgn (16-32 dry mile).
as N ¢ Gacoflex UA-60 Series ( various colon) applied 1 g.Usq (15 dry mast_
44. Deck:
Incline: 2
Foam: "Poly -lso" or "Poly -lso Special" with "Potyfoem 251" ar "Polyfoam 303 ". 1 In. min.
Base Coat "GacoSil S- 1000" applied at 1 pat /sq (10 dry mils).
Surfacing: "Gacoflex S- 1000" applied at 1 gaVaq (10 dry mils).
45. Deck: NC Incline: 1
Foam: "Polyfoem 251" or "Polyfoam 303", any thickness.
Surfacing: "Gecoflex Ure- Shield 7007 ", 40 dry mils.
OAF MATERIALS CORP, WAYNE NJ 07470 R1308 (N)
ASPHALT FELT SYSTEMS WITH NOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet (" GAFOLAS 475 Base Sheer) Is a suitable alternate for
Type 61 asphalt glass fiber ply sheet (" GAFGLAS Ply 4" or " GAFGLAS Pry 61 In the Class A.13 or C
roof systems indicated below.
The roof deck may first be covered with a Type 02 asphalt gates mat base sheet " GAFGLAS Sys-
tavern (Vent -Pty) perforated" or "GAFGLAS Stretevent (Vent•Pty) for mailable decks ". Perforated to be
mopped and naiable to be mechanically attached granuls aide down.
As an option Type 82 asphalt glass mat base sheet rGAFGI.AS #75 Base Sheet" or " GAFGLAS
Stretavent (Vent -Ply) far neilable decks") may be subshuted for G1 asphalt glass fiber ply sheet
(' GAFGLAS Ply 4" or " GAFGLAS Ply 0'1 u the nailed base pry in the following systems.
Bottom ply or bass sheet may be solid mopped, spot mopped or mechanically fastened.
Lkdess otherwise indicated. all insulations may be hot mopped or mechanically fastened
" GAFGLAS Flashing" or "Ruberoid" may be used for fleshing in any of the Class A. 6 or C sys-
tems listed below.
When "partite" is referenced, the Includes "GAFTEMP Partite" or eny other UL Classified peat*
Insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems list-
ed.
Structural cement fiber building units ere considered suitable to be included as a deck In the fol-
lowing Class A. B or C system. listed over C -10/32 or NC.
The use of gypsum board under any of the following Class A B or C Systems does not adversely
effect the rating. The use of 1/2 kt. min gypsum board is an aoaeptabte alternate for insulation over
C -15/32 decks.
The use of polystyrene insulation board between min 3/4 in. partite board and deck with rosin pa-
per (pertits/rosin paper /polystyrene/partite) is a suitable alternate for isocyanurate board in the fol-
lowing Clap A, B or C systems.
isotherm 11 may be subetttutad for any isocyanurste insulation in any of the following Classifica-
tions.
CLASS A.13 soul C.
Hot roofing asphalt for use with organic end glees feats or mod)flad bitumen membranes.
Gass A
1. Deck: C -18/32 Inclines 3
Insulation (Optionalk One or more layers partite, wood fiber, glass fiber. isory.nurate, u►*
thane, perlite /isocyenurate composite, perlite /urethane composite, wood fiber /Isocyenurete
composite. phenolic. any thickness.
Ply Sheet Three or more layers Type GI " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". hot
mopped
Surfacing: Gravel.
2. Deck: C-15/32 Mellow 2
Insulation tOptIonalk One or more layers partite, wood fiber, glass fiber, isocyanwats, ure-
thane. perlit./laocyanurate composite, penes/urethane composite. wood fib.r/tsocyanurats
composite phenolic, any thickness.
Ply Sheet Three or more layers Typo 61 " GAFGLAS Pry 4" or "GAFGLAS Pty 6".
Cap Shat One layer Typ. 03 " GAFGLAS Mineral Surfaced Cap Sheet ".
3. Deck NC Incline: 2
Inwlatbn (OptlaulI One or more layers partite, wood fiber. glue fiber. isooyanurate, au*
thane, partite/ aocyanurate composite. partite/urethane composite. wood Sber/socyemuste
composite. phenolic. 2 in. max.
Ply Sheet Two or more layers Type 01 " GAFGLAS Ply 4" or "GAFGLAS fly B ".
Cap Sheet One layer Type 09 " GAFGLAS Mineral Surfaced Cap Sheet ".
4. Deck NC Incline 1/2
Inaulsdoiu One or two layers "Isotherm R", 4 in. max, hot mopped.
My Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system.
5. Deck: C Inctineu 1
Slip Sheet (Optlarralt Rad rosin paper, nailed to deck.
Baas Sheet One layer of Type 02 " GAFGLAS *76 Sae. Sheet' (may be nailed).
Ply Sheet One or more layers of Type 01 " GAFGLAS Pry 4" or GAFGLAS Ply 8 ".
Cap Shari One boar of Type 0-3 " GAFGLAS Mineral Surfaced Cap Sheet ".
0. Morn NC triclinic 3
Boa Sheet One layer of Type G2 " GAFGLAS *75 Baas Shpt ".
Ply Sheet One or more *ere of Type GI " GAFGLAS Ply 4" er GAFGLAS Fly 6 ".
Cap Mast One layer of Type 84 "GAFOI.AS Mineral Surfaced trap Shoot ".
LOOK FOR MARK AN carload
MIAMI SHORES VILLAGE, FLA.
JOB
ADDRESS i/ 7 /11(C `7 ,O
N
949
INSPECTION
TIME READY /9-• ' )(
REMARKS•
INSPECTOR
DATE
STATE OF FLORIDA,
COUNTY OF DADE. j ss.
MIAMI SHORES VILLAGE
Building Inspector
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Budding Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the iuilding Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at budding during progress of the work.
26 squares T 1�Y� �A �:i: .... ,19. -ZL
Owner's Name and Address 1.Irs. Leonard. G. "TU$SbaU:'1 - No 1 ] 2&.._... Streeter. f'ia 92th 1St_
R egistered Architect and /or Engineer :... • .. ... ...... „- m.,-- ,. .....
Name and address of licensed contactor Lan_ a R f s . & Tile Co., Inc': 5'Z3 .i`l e ;I 71st !='ial_1i , )?1a s ,
Location and legal description of lot to be built on: 33150
Lot Block Subdivision
Street and Number where work is to be done ...17 , .F, a.._ th ._:
trirl reroof: Tear off ex stin.a roofi_ns,
State work to be done and purpose of building (by floors) Co ...._:_.. Y,_ __......_...__..
tin ca 1 -30: felt to sheathini;,. o?) 1- 90.1b.._.slate with hot snha1_t ayE?.cover
with a 1 afire.' of..._.at rd uhite. -- .caaert shingle file. and for no other purpose.
New Building Remodeling Addition Repairs PT DQF No. of Stories 1
To be constructed of Kind of foundation Roof Covering....3.1.1.nI ae ....
4
Estimated Total cost of improvements $ ... . 7 J..a . 69 0 e 00 Amount of Permit 7200
Zone cubage required _....__._...plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contra rs or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspect: on the site work such u die notice
or notices as arc required by the Act. The undersigned agrees to employ only such bco et be performe under this
pennit, as are licensed by Miami Shores Village.
r ii_ mss.. ..
Remarks (Signed)
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are . �
V Permit No ..__-Iv ? ( Date 3 2 _ r ? ' � Re d, Sworn to and Subscribed before me.
Disapproved �' Date.._..__ '.__�`__.._ ►
'4 ' (�...._. � C� Notary Public, State of Florida
(Signed) ...
My Commission Expires
to me well known,
PLANNING BOARD _.._.... -.DATE
Chairman Member
.fernber Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after npproval has been obtained from
the Planning Board.
A re fee of $1.00 will be charged when such re inspection is made necessary by improper notice for inspection or faulty
materials and/or workmanship.