Loading...
MECHANICALMIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approya1 of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Dates4 2'il 1O , 19 Owner's Name and Address .... ..Edgar...Z._..Wells No.97 &7 Street..H .E...._ Avenue Registered Architect and /or Engineer Name and address of licensed contractor Fla.. 13nx_ /Bisctzyne Annex Location and legal description of lot to be built on: Lot Block Subdivision. Street and Number where work is to be done 853__N..E.._._96th.Street State work to be done and purpose of building (by floors) Installation. . of ..IllO,__O.O.Q_B.T..U__Coleman. f_orce._.air_furnace and for no other purpose. New Building Remodeling. Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ Amount of Permit $ Zone cubage required .Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5968, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. J ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No Date Read, Sworn to and Subscribed before me. Disapproved Date Notary Public, State of Florida (Signed) Building Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Date PERMIT APPLICATION FOR MIAMI SHORES VILLAGE /5 Tax Folio Job Address si Legal Description 3 i Owner/Lessee / Tenant / C, / . S q 1 (e` /2 n 3 � 6 / Owner's Address 6 s i Contracting Co. /'f /G9rr7 ; A-"n ( Qualifier _IC/A» iti e h J€ 1 5, State # ( / 6 . Municipal # Historically Designated: Yes Master Permit # Phone 75 — t f f ) 1 13.E Address / i Xl a' 17a ' / Phone r3 S) Competency # Ins. Co. Address Address Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUIL IN GG ELECT4ICAL PLUMBING VIECHArIICAL 3OOFING PAVING FENCE SIGN WORK DESCRIPTION eL'o i ei-i Not My as to Owner and/or =mission Expires: ndo President Date N•" OSU JEGAMAW) Auk MY OQ IS�ON Il CC 727495 EXP1R6S: rch 24 2002 Bondedihru NON Pulls er _ Rf „h FEES: PERMIT / 3k ON 4- M Commission Expires: C.C.F. I ' b O NOTARY Da Square Ft. Estimated Cost (value) 2 . WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructio and zoning. Furth- ore, I authorize the above -nam- • contractor to do the work stated. ractor or Owner - Builder Date 1/ _Av./ / 0 -/9 q No : as to Contractor or 0 er- Builder Date JOSUE - 0 MY COMMISSION # CC 727495 =a •., EXPIRES: Mavh 24, 2002 yip; Banded rnruAdetery Public Underwriters BOND TOTAL DUE /3 t9e /6 APPROVED: Zoning �j B � ��g Electrical Mechanical e J a v / 0 / Plumbing Engineering Outside db: Inside db: Design TD: RIGHT -J LOAD AND EQUIPMENT SUMMARY File name: LU I S For. LUIS HERNANDEZ 853 NE 96 ST MIAMI FL 33138 By MIAMI KOOL INC 14603 WEST DIXIE HWY NORTH MIAMI 3059409666 47 Deg F 70 Deg F 23 Deg F Outside db: Inside db: Design TD: Daily Range Rel. Hum. : Grains Water FL 33161 Job # Wthr Miami_ FL Zone Entire House WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS 10/20/98 90 Deg F 75 Deg F 15 Deg F L 50 % 56 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 59868 Btuh Structure 57153 Btuh Ventilation Air 0 CFM Ventilation 0 Btuh Vent Air Loss 0 Btuh Design Temp. Swing 3.0 Deg F Design Heat Load 59868 Btuh Use Mfg. Data n Rate/Swing Mult. 0.95 INFILTRATION Total Sens Equip Load 54295 Btuh Method Simplified LATENT COOLING EQUIP LOAD SIZING Construction Quality Average Fireplaces 0 Internal Gains 690 Btuh Ventilation 0 Btuh HEATING COOLING Infiltration 5191 Btuh Area (sq.ft.) 1975 1975 Tot Latent Equip Load 5881 Btuh Volume(cu.ft.) 20408 20408 Air Changes/Hour 0.8 0.4 Total Equip Load 60176 Btuh Equivalent CFM 273 136 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make LENNOX Make LENNOX Model 10 KW Model HS26 /CB29 Type ELECTRIC HEAT Type AI R COOLED Efficiency / HSPF 100.00 COP/EER/SEER 13.00 Heating Input 59868 Btuh Sensible Cooling 57900 Btuh Heating Output 59868 Btuh Latent Cooling 0 Btuh Heating Temp Rise 18 Deg F Total Cooling 57900 Btuh Actual Heating Fan 3056 CFM Actual Cooling Fan 3056 CFM Htg Air Flow Factor 0.051 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh Space Thermostat Load Sens Heat Ratio 91 MANUAL J: 7th Ed. RIGHT -J: V1 3.0.13 S/N 12034 Printout certified by ACCA to meet all requirements of Manual Form J Procedure C - Latent Infiltration Gain Procedure D - Equipment Sizing Loads RIGHT -J CALCULATION ' PROCEDURES A, B, C, D Job #: Zone: Entire House Procedure A - Winter Infiltration HTM Calculation* LUIS 10/20/98 Procedure B - Summer Infiltration HTM Calculation* File name: 1. Winter Infiltration CFM 0.8 AC/HR x 20408 Cu.Ft. x 0.0167 = 2. Winter Infiltration Btuh 1.1 x 273 CFM x 23 Winter TD = 3. Winter Infiltration HTM 6898 Btuh / 326 Total Window = and Door Area 273 CFM 6898 Btuh 21.2 HTM 1. Summer Infiltration CFM 0.4 AC/HR x 20408 Cu.Ft. x 0.0167 = 2. Summer Infiltration Btuh 1.1 x 136 CFM x 15 Summer TD = 3. Summer Infiltration HTM 2249 Btuh / 326 Total Window = and Door Area 136 CFM 2249 Btuh 6.9 HTM 0.68 x 56 gr.diff. x 136 CFM = 5191 Btuh 1. Sensible Sizing Load Sensible Ventilation Load 1.1 x 0 Vent.CFM x 15 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) + 57153 Btuh Sum of Ventilation and Structure Loads = 57153 Btuh Rating and Temperature Swing Multiplier x 0.9 5 RSM Equipment Sizing Load - Sensible + 54295 Btuh 2. Latent Sizing Load Latent Ventilation Load 0.68 x 0 Vent.CFM x 56 gr.diff. = 0 Btuh Internal Loads = 230 x 3 No. People + 690 Btuh Infiltration Load From Procedure C + 5191 Btuh Equipment Sizing Load - Latent = 5881 Btuh *Construction Quality is: MANUAL J: 7th Ed. RIGHT -J: V a No. of Fireplaces is: 3.0.13 S/N 12034 Printout certified by ACCA to meet all requirements of Manual Form J 0 LUIS Jobll Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire House 10/20/98 IWUNuu,1. /MEAL A /III-, J -V.1. any 16VJ4 NameofRoom Entire House MASTER BEDROOM BATHROOM OPEN AREA Running Ft. Exposed 518.0 Ft. 60.0 Ft. 20.0 Ft. 56.0 Ft. en Room Dimensions, 0.0 t. 15.0 x 15.0 Ft. 5.0 x 5.0 Ft. 15.0 x 13.0 Ft. Ceiings,Ft Condit Option 9 d 8 t /cool 8 t /cool 8.0 heat /cool TYPE OF CST HTM Btuh Btuh Btuh Btuh EXPOSURE NO. Htg Clg 1 Htg Clg Htg Clg 1 Htg Clg 1 Htg Clg 5 Gross 14B 5 • •►•• '• •••• i• .... .•.. •••• Exposed • •••. • •.•. * •.•. •••• •••• Walls .• •••• ...• •••• '. .... .... *••• Partitions 0 0 0 0 0 mt. 44.. 0 • 0 • .*•• 0 •••• ••.• .• ,. '. •.•• •••* ►••* .. '• '• ..•• ma. •••• 6 Windows and 5A •* '• '• .••. 105 • *e. Glass Doors .. '► ,• •••* 0 •••• Heating .. '• . •... 0 .•.. 0 0 •• 0 0 ••.• 0 0 ..* 0 0 •.. 0 0 ..*. •. 0 0 ••** ••• •.• 0 .... .. 0 0 .••• p. ••• 0 •H• 7 Windows and North 11.1 's 2324 44.. * ••.• Glass Doors NE/NW 0.0 • 0 * • •••. Cooling E/W 45.2 * 3171 • 1839 Am.. *s•. 0 0 0 0 •• *. O .•.• •••• 8 Other doors a 0.0 0.0 b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 14B 4778 15825 10527 1431 952 530 353 1444 961 Exposed b 0 0 0 0 0 0 0 0 0 Walls and c 0 0 0 0 0 0 0 0 0 Partitions d 0 0 0 0 0 0 0 0 0 0 0 ' 0 0 0 0 0 e 0 0 0 0 0 0 0 0 0 f 0 0 0 0 0 0 0 0 0 10 Ceilings a 16A 13.8 18.8 1375 27210 37112 225 3100 42 25 344 470 195 2687 3664 b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 11 Floors a 19A 3.6 0.0 1975 7086 225 807 25 90 195 700 0 0 0 b 0.0 0.0 0 0 O 0 0 0 0 0 O 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 12 Infiltration a 21.2 6.9 326 6898 2249 48 1016 331 0 0 0 12 254 83 13 Subtot Btuh Loss= 6+8. ±11 +12 .... 59868 ssss *••* 6773 ssss *s *s 964 * *s* ***• 5189 *s ** 14 Duct Btuh Loss 0% 0 ••a• 0% 0 ssss 0% 0 .... 0% 0 * * ** 15 Total Btuh Loss = 13+14 s *•* 59868 * **s •*** 6773 • * ** **** 964 s *s* •••• 5189 * *** 16 Int. Gains: People ® 300 3 ssss 900 2 s * ** 600 0 * *s* 0 1 ** ** 300 Appl. @ 1200 0 ssss 0 0 * *s* 0 0 ssss 0 0 • *** 0 17 Subtot RSH Gain =7 +8. ±12 +16 •••• s*** 57153 *s *s ssss 8115 ssss ssss 822 ssss sass 5452 18 Duct Btuh Gain 0% s*** 0 0% * * ** 0 0% * * *s 0 0% •* ** 0 19 Total RSHCrain= (17 +18)sPLF 1.00 **** 57153 1.00 ssss 8115 1.00 ssss 822 1.00 ►••. 5452 20 CFMAirRequired *s•• 3056 3056 **** 346 434 ***' 49 44 sss• 265 292 LUIS Jobll Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire House 10/20/98 LUIS Job!l Zone: Entire House 10/20/98 Printout certified by ACCA to meet all requirements of Manual J Form rvuuvvrv.r 1WLU. rtrwu -r J.U.13 S/N 12034 Name of Room BEDROOM 2 BEDROOM 1 LIVING ROOM FAMILY ROOM Running Ft. Exposed Wall 58.0 Ft. 56.0 Ft. 78.0 Ft 82.0 Ft. el Room Dimensions, 19.0 x 15.0 Ft 12.0 x 16.0 Ft. 15.0 x 24.0 Ft. 17.0 x 29.0 Ft. Cciings,Ft Condit Option 6 heat/cool 6 .0 heat /cool 14 .0 heat /cool 14.0 heat /cool TYPE OF CST HTM Btuh Btuh Btuh Btuh EXPOSURE NO. Htg Clg I Htg Clg I Htg Clg I Htg Clg I Htg Clg 5 Gross 19B 5• •••• •••• •••• 1092 5 •*• •••• 1148 t*•• 5555 Exposed 55 •••• •••• •••• 0 •••• •••• 0 •••• tt** Walls End 45 •••• •••• •••• 0 **as •••• 0 ••t• •••• Partitions 0 0 0 0 0 ** •••• 0 ••• 0 •••• *••* 0 •••• •••• •• •••• ••• 0 •••• •••• 0 •••• •••• •• •••• ••• 0 •••• •••• 0 •••• ••• 6 Windows and 5A •• •••• ••• •••• 120 104 9 •*•• Glass Doors 5* •••• ••• •••• 0 0 *a• Heating 55 *••1 ** **•• 0 0 *••• 0 0 •• 0 0 •••• 0 0 •••• 0 0 •••• 0 0 •.•* •* **•• 0 •••• ••• 0 0 •••• 55 •••• 0 •••• •••• 0 0 •••• 7 Windows and North 11.1 ** 106 •••• 158 *• 352 •••• 1320 Glass Doors NE/NW 0.0 ••• 0 •••• 0 '• 0 5••• 0 Cooling E/W 45.2 •• 444 5••• 0 ••• 0 '• 0 0 0 5555 0 •••• 0 •••• 0 8 Other doors 0.0 0.0 ..,1 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 14B 19 57 969 1424 1032 3918 2274 1028 3405 2265 Exposed b 0 0 0 0 0 0 0 0 0 Walls and c 0 0 0 0 0 0 0 0 0 Partitions d 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 e 0 0 0 0 0 0 0 0 0 f 0 0 0 0 0 0 0 0 0 10 Ceilings a 16A 13.8 18.8 210 2893 3946 192 2645 3608 360 4960 6765 108 5621 7667 b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 C 0.0 0.0 0 0 0 0 0 o 0 0 o 0 0 0 II Floors a 19A 3.6 0.0 210 753 192 689 360 1292 408 1464 0 0 0 b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 12 Infiltration a 21.2 6.9 24 508 166 18 381 124 60 1270 414 120 2539 828 13 Subtot Btuh Loss=6+8. ±11 +12 •••• 5822 5558 e••• 5296 •••• •• 11463 5 ••• 5 ••• 14078 5 ••• 14 Dud Btuh Loss 0% 0 •••• 0% 0 •••• 0% 0 •••• 0% 0 tt 15 Total Btuh Loss =13 +14 •••• 5822 ••e• 5 ••• 5296 55 •• •• 11463 * 5515 14078 5 ••• 16 Int. Gains: People ® 300 0 •••• 0 0 •••• 0 0 •••• 0 0 •••• 0 Appl. @ 1200 0 •••• 0 0 •••• 0 0 •••• 0 0 5t•• 0 17 SubtotRSHGain °7 +8.. +12 +16 •••• •••• 5676 5 t•• • 555 9906 t 555 58 10336 5 •• 5 55 12080 18 Dud Btuh Gain 0% •t 0 0% 5555 0 0% • 0 0% 5•t5 0 19 Total RSHGain =(17 +18)•PLF 1.00 5555 5676 1.00 5555 4906 1.00 5555 10336 1.00 ••e• 12080 20 CFMAirRequired •5t• 297 304 5858 270 262 858 585 553 ••• 719 646 LUIS Job!l Zone: Entire House 10/20/98 Printout certified by ACCA to meet all requirements of Manual J Form I —c' m Name of Room Running Ft. Ex Room Dimensic Ceiings,Ft t Option DINNING 1 8 ROOM 58.0 Ft. .4 .0 Ft. it /cool 1 8 KITCHEN I.0 Ft. 5.0 Ft. it /cool Ft. Ft. Ft. x Ft. TYPE OF CST HIM Btuh Btuh Btuh Btuh EXPOSURE NO. Htg Clg g Clg Htg Clg I Htg Clg Htg Clg 5 ( •• *8*4 888* •••• * *•► •••• *8•* *ete Exposed •• •••• *88* et•• •••• •••• e••• ••M Walls and •• •••• •••• •••• •••• •••• •••• •••• as O O O O 0 N MS O 8 * ** .1 .1.* *•88 * * ** *88* *8 ** e* *88* *•M **** *8 *• SS8* ** ** **t* *8 MO *►** *08* *88* • * ** • * ** *• ** 6 Windows and •• 175 •••• 210 •••• ••** •••• Glass Doors tt 0 ** ** 0 •••• •••• *0 • 1 Heatirg •• 0 •••• 0 •••• •••• •••• O O •• 0 0 •••• 0 0 * *** *** t e•* •• 0 *St* 0 •••• *e ** •*** ** 0 • * ** 0 •••• * *** •••• 7 Windows and 11.1 '• 117 *••• 106 •**• *• *• Glass Doors W 0.0 '• 0 •••• 0 •••• •••• Cooling 45.2 ** 0 *•t• 444 •ets *88* 0 0 •••• 0 *• ** •••• •••• 46 •••• •••• •••• 0 •••• •••• 8 0.0 0.0 0.0 0.0 0 0 0 0 0 0 9 1471 978 376 1245 828 Exposed b 0 0 0 0 0 Walls and c 0 0 0 0 0 Partitions d 0 0 O 0 0 0 0 0 0 0 e 0 0 0 0 0 f 0 0 0 0 0 10 Ceilings a 16A 13.8 1 210 2893 3 150 2067 2819 b 0.0 0 0 0 0 0 c 0.0 0 0 0 0 0 11 Floors a 19A 3.6 0.0 210 753 150 538 0 0 0 b 0.0 0.0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 12 Infiltration a 21.2 6.9 20 423 138 24 508 166 13 Subtot Btuh Loss =6+8.:+11 +12 ** ** 5715 •••• *• *t 4 568 • •••• * *•* *t** •••• 14 Dud Btuh LOSS 0% 0 •••• 0% 0 •tt* % **** % *t•* 15 Total Btuh Loss = 13 +14 *••* 5715 * * *• ••w* 4 568 •••* "" * *•s •t** •••• 16 Int. Gains: People ® 300 0 ma 0 0 •••• 0 •••• •••• Apl. p @ 1200 0 *►*t 0 0 •••• 0 •••• •••• 17 Subtot RSH Crain =7 +8. ±12 +16 •88• •••• 5357 * •••• 4408 •••• *••• •••• •••• 18 Duct Btuh Gain 0% •••* 0 0% •••• 0 % **•* % 'psi 19 Total RSH Gain=(17 +18)*PLF 1.00 •••* 5357 '1.00 "" 4 408 •••• •••• 20 CFMAirRequired •••• 292 286 "" 233 236 •••• •••• LUIS Job# Zone: Entire House 10/20/98 Printout certified by ACCA to meet all requirements of Manual J Form MANUAL J: 7th Ed. RIGHT -J: V RIGHT -J WINDOW DATA MASTER BEDROOM Job #: Filename: LUIS 10/20/98 W S D W G L S S O N A S 0 0 W C W S N K I AL OT H V G N H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D G Z L 0 X Y T M R R a n n a c n n d y 3 90 1.0 2.0 2.0 4.0 11.0 12.0 0.0 a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 a n w a c n n n y 3 90 1.0 2.0 1.0 8.0 63.0 24.0 1.9 BATHROOM 3.0.13 S/N 12034 OPEN AREA a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 BEDROOM 2 a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 12.0 9.6 BEDROOM 1 a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 18.0 14.4 LIVING ROOM a n s a c n n d y 3 90 1.0 2.0 2.0 6.0 19.0 60.0 32.0 FAMILY ROOM a n n a c n n d y• 3 90 1.0 2.0 1.0 8.0 11.0 120 0.0 DINNING ROOM a n s a c n n d y 3 90 1.0 2.0 2.0 6.0 19.0 20.0 10.7 KITCHEN a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 12.0 9.6 a n w a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 u is 4-1 ear sum de -� gs3g absr- I/la 441 Shoe E5 F3 3/3 p C•K.1 w ef t& C a NN o X 0.0sEElz- Co ld/AMIE , 44$ .2A. -O(bO Pt IV kAcktstalett Newt to tt W Oties 1 ,'4' CoT ytr 141 b E4 ;11 cofpre VrQr,r * oa ECU As, ra K ik Cie ^9 to x_/$ �1•1 ftt Roow LiJttd4 20 ®� l5` 7-- `f 1 1-4 C3eciv-oor Ii 2115 ice rtJ 1 -UPS - 1er de gS 3 tile. co si- - - Al vim; S'karze3 St. eArtea — — —z 1 < 11 c_rc I� r /5 ,L.E NW XI i3.o sE'- CeNdf NSE .N$ -21. - ObO A tr4antd lea Seecrea. totW L 4ES 1 he Coffer 141 6 E4 eorare Draxty * oat EQti As, r : t Srlrks IEuJ :Lh 120 fe L Jit'r' r c : Y 2 Y eKtsTl nj !1- Uri 1' ?o n/ AAAsTer_ Sit - re 1� G :lv X 1: -t . Outside db: Inside db: Design TD: RIGHT -J LOAD AND EQUIPMENT SUMMARY File name: LUI S For. LUIS HERNANDEZ 853 NE 96 ST MIAMI FL 33138 By MIAMI KOOL INC 14603 WEST DIXIE HWY NORTH MIAMI 3059409666 FL 33161 Jobfi Wthr MiamiAP_(S) FL Zone Entire House WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS 47 Deg F 70 Deg F 23 Deg F 10/20/98 Outside db: 90 Deg F Inside db: 75 Deg F Design TD: 15 Deg F Daily Range L Rd. Hum.: 50 % Grains Water 56 gr HEATING SUMMARY SENSIBLE COOLING EQUIP LOAD SIZING Bldg. Heat Loss 59868 Btuh Structure 57153 Btuh Ventilation Air 0 CFM Ventilation 0 Btuh Vent Air Loss 0 Btuh Design Temp. Swing 3.0 Deg F Design Heat Load 59868 Btuh Use Mfg. Data n Rate /Swing Mult. 0.95 INFILTRATION Total Sens Equip Load 54295 Btuh Method Simplified LATENT COOLING EQUIP LOAD SIZING Construction Quality Average Fireplaces 0 Internal Gains 690 Btuh Ventilation 0 Btuh HEATING COOLING Infiltration 5191 Btuh Area (sq.ft.) 1975 1975 Tot Latent Equip Load 5881 Btuh Volume(cu.ft.) 20408 20408 Air Changes/Hour 0.8 0.4 Total Equip Load 60176 Btuh Equivalent CFM 273 13 6 HEATING EQUIPMENT SUMMARY COOLING EQUIPMENT SUMMARY Make LENNOX Make LENNOX Model 10 KW Model HS26 /CB29 Type ELECTRIC HEAT Type AIR COOLED Efficiency / HSPF 100.00 COP/EER/SEER 13.00 Heating Input 59868 Btuh Sensible Cooling 57900 Btuh Heating Output 59868 Btuh Latent Cooling 0 Btuh Heating Temp Rise 18 Deg F Total Cooling 57900 Btuh Actual Heating Fan 3056 CFM Actual Cooling Fan 3056 CFM Htg Air Flow Factor 0.051 CFM/Btuh Clg Air Flow Factor 0.053 CFM/Btuh Space Thermostat Load Sens Heat Ratio 91 MANUAL J: 7th Ed. RIGHT -J: VI 3.0.13 S/N 12034 Printout certified by ACCA to meet all requirements of Manual Form J RIGHT -J CALCULATION ' PROCEDURES A, B, C, D Job #: Zone: Entire House Procedure A - Winter Infiltration HTM Calculation' File name: LUIS 10/20/98 1. Winter Infiltration CFM 0. 8 AC/HR x 20408 Cu.Ft. x 0.0167 = 2. Winter Infiltration Btuh 1.1 x 273 CFM x 23 Winter TD = 3. Winter Infiltration HTM 6898 Btuh / 326 Total Window = and Door Area 273 CFM 6898 Btuh 21.2 HTM Procedure B - Summer Infiltration HTM Calculation' 1. Summer Infiltration CFM 0.4 AC/HR x 20408 Cu.Ft. x 0.0167 = 2. Summer Infiltration Btuh 1.1 x 136 CFMx 15 Summer TD = 3. Summer Infiltration HTM 2249 Btuh / 326 Total Window = and Door Area 136 CFM 2249 Btuh 6.9 HTM Procedure C - Latent Infiltration Gain 0.68 x 56 gr.diff. x 136 CFM = 5191 Btuh Procedure D - Equipment Sizing Loads 1. Sensible Sizing Load Sensible Ventilation Load 1.1 x 0 Vent.CFM x 15 Summer TD = 0 Btuh Sensible Load for Structure (Line 19) + 57153 Btuh Sum of Ventilation and Structure Loads = 57153 Btuh Rating and Temperature Swing Multiplier x 0.9 5 RSM Equipment Sizing Load - Sensible + 54295 Btuh 2. Latent Sizing Load Latent Ventilation Load 0.68 x 0 Vent.CFM x 56 gr.diff. = 0 Btuh Internal Loads = 230 x 3 No. People + 690 Btuh Infiltration Load From Procedure C + 5191 Btuh Equipment Sizing Load - Latent = 5881 Btuh 'Construction Quality is: MANUAL J: 7th Ed. RIGHT -J: V a No. of Fireplaces is: 3.0.13 S/N 12034 Printout certified by ACCA to meet all requirements of Manual Form J 0 I •■ N 01 - MJiNU L J: tin Name of Room Running Ft. E,n Room Dimensions, na s Wall luvnr -r Entire 3.U.13---. WIN House 518.0 Ft. 0.0 t. 1203 MASTER BEDROOM 60.0 Ft. 15.0 x 15.0 Ft. BATHROOM 20.0 Ft. 5.0 x 5.0 Ft. OPEN AREA 56.0 Ft. 15.0 x 13.0 Ft. Ceiings,Ft C,ondit Option 9.3 d 8.0 heat/cool 8.0 heat/cool 8.0 heat /cool TYPEOF CST HIM Btuh Btuh Btuh Bath EXPOSURE NO. Htg Clg Htg Clg Htg Clg tg Clg Htg Clg 5 Gross a 14B 5104 r5* *5** 5555 *55* iii 5555 5*55 555* Exposed b r** SS .I.1 r5* *555 Si** *555 *SSS iSis Walls and e 0 555 5555 55* 5555 .55* 5555 555* 5555 O O O O 5s5 5555 O 55* 5555 O 5555 555* O *555 5555 rss rss rss * *SS ***s *85* 555 rss t5* *Si* 555* 555* ws and rs r5* **it Sass 105 5555 Glass Doors *5 555 rss 5555 0 *i* Heating 55 r** rss 5555 0 5555 9 O O 55 O 0 r*s O O r** O O 5555 O 0 555* 5* 0 5555 i1 5* 0 5555 ** 0 Si** *Sit *1 0 555* 7 Windows and North 11.1 r** 2324 5555 165 et*** 5555 Glass Doors NE/NW 0.0 0 555* 0 rss r55 *it* Cooling E/W 45.2 r** 3171 rss 1839 *555 ssss srusw 0.0 0 5*** 0 O 1455 O r55 O O ass* O 5555 55** 8 Other doors 0.0 0.0 L 0.0 0.0 O O O O 0 O O 0 O O 9 Net a 14B 4778 15825 10527 1931 952 160 530 353 1444 961 Exposed b 0 0 0 0 0 0 0 0 0 0 Walls and c 0 0 0 0 0 0 0 0 0 0 .____._ d O O O .. 0 0 O 0 0 0 0 0 O 0 0 e 0 0 0 0 0 0 0 0 0 0 f 0 0 0 0 0 0 0 0 0 0 10 Ceilings a 16A 13.8 18.8 1975 27210 37112 225 3100 4228 25 344 4711 195 2687 3664 b 0.0 0.0 0 0 0 0 0 0 0 0 0 0 0 0 c 0.0 0 0 0 0 0 0 0 0 0 0 0 0 11 Floors a 19A 3.6 0.0 1975 7086 225 807 25 90 195 700 O O O b 0.0 0.0 0 0 O 0 0 O 0 0 O 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 12 Infiltration a 21.2 6.9 326 6898 2249 48 1016 331 0 0 0 12 254 83 13 Subtot Btuh Loss= 6 +8. ±11+ 2 5555 59868 *5t* *55* 6773 5555 * * ** 964 ssss 5555 5189 S*•* 14 Dud Btuh Loss 0% 0 * * ** 0% 0 sass 0% 0 * * ** 0% 0 **** 15 Total Btuh Loss= 13 +14 5555 59868 555* 555* 6773 5555 *sss 964 *** 5555 5189 •• 16 Int. Gains: People @ 300 3 5555 900 2 5 s** 600 0 5555 0 1 ssss 300 Appl. @ 1200 0 555* 0 0 * 0 0 5555 0 0 5555 0 17 Subtot RSH Gain =7 +8. ±12+16 5555 *SS* 57153 *sss sss* 8115 ss ** 555* 822 *5** 5555 5452 18 Duct Btuh Gain 0% *ass 0 0% 5555 0 0% 5588 0 0% **SS 0 19 Total RSHGain= (17 +18)*PLF 1.00 a*** 57153 1.00 * * ** 8115 1.00 5555 822 1.00 * * * 5452 20 CFMAirRequired ssss 3056 3056 ••a• 346 434 ssss 49 44 a*** 265 292 LUIS Job# Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire Hou 10120/98• 3 0 o,,. mac.,,, Name of Room BEDROOM 2 BEDROOM 1 LIVING ROOM FAMILY ROOM Running Ft. Exposed Wall 58.0 Ft. 56.0 Ft. 78.0 Ft. 82.0 Ft. Room Dimensions, 15.0 Ft. 16.0 Ft. 24.0 Ft. 17.0 x 24.0 Ft. Ceiings,Ft Condit Option :at /cool at /cool 7 at /cool 14.0 heat /cool TYPE OF CST HTM Btuh Btuh Btuh Btuh ). Htg Clg Htg Clg Htg Clg Htg Clg Htg Clg 5 B nt** *tat fi at** 1 092 t**• **** 1148 'I*" 'I*" •*•*" ,*5* IMAM **Si *tit 0 **AM tit sM * 0 i* *ill Walls and c vi** **if tats tars 0 tats "" 0 sews •tit Partitions * a•t saws * *** **as 0 tt•* awe 0 sett asas ** Mitt *Si* 0 • *•a •is* 0 •*t* si*a *•t watt *** 0 **a* *at* 0 **SS *ar* Windows and 8 * 210 *• *• iii *s•* 120 1049 asst Glass a Doors aw 0 •• a** a*wa 0 0 ►tai Heating as 0 ••a sat tiw* 0 0 as *e 0 ••a• u *****I* as 0 0 *•w* a* 0 watt 0 sass IMAM 0 0 asst 55 0 *It** 0 ***5 •e*• 0 0 •s* 7 Windows and North 11.1 •*• 106 *s ** 158 32 ***• 352 120 ass* 1320 Glass Doors NE/NW 0....um *** 0 **•* 0 0 ...um 0 0 **** 0 Cooling E/W 45.2 * 444 * **• 0 0 ■••• 0 0 •*** 0 SE /SW n n *a* n * *•* n n **Mt n 0 p" 0 ut 0 our* 0 0 .4,.... .4,.... .4,.... 0 8 0.0 0.0 0.0 0.0 9 B 1457 1424 1032 3418 2274 1028 3405 2265 0 0 0 0 0 0 0 0 Walls and c 0 0 0 0 0 0 0 0 a r ...one d 0 ., 0 0 0 0 0 0 0 e 0 0 0 0 0 0 0 0 0 f 0 0 0 0 0 0 0 0 0 10 Ceilings a 16A 13.8 18.8 210 2893 3946 192 2645 3600 360 4960 6765 408 5621 7667 b 0.0 0 0 0 0 0 0 0 0 0 c 0.0 0 0 0 0 0 0 0 0 0 ., 11 Floors a 19A 3.6 .0 210 753 192 689 360 1292 408 1464 b 0.0 0.0 0 0 0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 0 0 0 0 12 Infiltration a 21.2 6.9 24 508 166 18 381 124 60 1270 914 120 2539 828 13 SubtotBtuhLoss= 6+8. ±11 +12 **** 5822 *■•* **•• 5296 ** ** *a*a 11463 * * *• twit 14078 •••• 14 Duct Btuh Loss 0% 0 .*•.8. 0% 0 ems. 0% 0 *••* 0% 0 «as 15 Total Btuh Loss =13+14 s*** 5822 **** ' s• 5296 *••* ' 11463 asst saes 14078 "'Ps "'Ps 16 Int. Gains: People @ 300 0 * *** 0 0 ***t 0 0 •••• 0 0 •sas""" 0 Appl. @ 1200 0 ***• 0 0 •••s 0 0 •••* 0 0 •*** 0 17 SubtotRSHGain =7 +8..1-12 +16 ***• *ss* 5676 **** *Ai* 4906 **** •s•• 10336 • *s• •••• 12080 18 DuctBtuhGain 0% •*** 0 0% Mss* 0 0% rats 0 0% •••• 0 19 Total RSHGain= (17 +18)•PLF 1.00 ** 5676 1.00 **** 4906 1.00 •*** 10336 1.00 •••* 12080 20 CFMAirRequred **** 297 304 *••• 270 262 ' 585 553 a*a• 719 646 , „u..,f.�.J. ,�, LA.. , ,l,..r,1, 3 I I I I 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LUIS Job# 13- Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire House 10/20/98 LUIS Jobil Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire House 10'/20/98 avuuxa./ru,+. imnu Name of Room navniv. DINNING 3n13- unx ROOM 14,...,1 KITCHEN Running Ft. Expo Wall 58.0 Ft. 50.0 Ft. Ft. Ft. � Room Dimensions, 14.0 Ft, 15.0 Ft. Ft. x Ft. Ceiings,Ft dit Option tat /cool heat /cool TYPE OF iT HTM Btuh Btuh Btuh Built Bh EXPOSURE ). Htg Clg Htg Clg Htg Clg Htg Clg Htg Clg 5 IB i5*• 5555 •••• *555 *55* it ** *55* *55* •••• •••• ••5• •••• •••• •••• •t•• •••• •••• •••• •••• •••• * *•• **t* 31.0131.01 ►• sit* 0 0 0 0 0 MR• 5555 0 Si** s *5* 5 *** **Si * *** •*5* .*5* ***le *it* .•.11. *it* 5* ** *55• *St* •••• *• ** *i 555* •• *58* *•5• *SS* Windows and •• 175 •••• 210 •• *• •5 *5 *t•* Glass Doors •• 0 •••• 0 •••• •••• •••• Heating •• 0 •••• 0 •••• • ••s •• *. 0 0 ** 0 0 ***► 0 0 **** *•55 **t► 55 *s 0 0 •••• •••► 0 0 a ** RIM* tst■ 1 i•• 11.1.1r8 11.1.1r8 *t•► 7 Windows and North 11.1 •••• 117 10 *••• 106 •••• •••• Glass Doors NW 0.0 • *•• 0 0 •••• 0 • *•* *••* Cooling 45.2 •••* 0 12 * * ** 444 •••• miss SE/SW n n 0 •••• n 0 •••• 0 *55* •►s► 2 •••• 46 as* *5•► 0 •••• 0 •••• as 8 0.0 0.0 0.0 0.0 0 0 0 0 0 0 9 B 1471 376 1245 Exposed b 0 0 0 Walls and c 0 0 0 .........,..s ,. 0 0 0 0 0 0 ., 0 0 0 e 0 0 0 0 f 0 0 0 0 10 Ceilings a 16A 13.8 1 A ❑ 210 2893 3946 150 2067 2819 b 0.0 0 0 0 0 0 c 0.0 0 0 0 0 0 11 Floors a 19A 3.6 0.0 753 150 538 0 0 0 b 0.0 0.0 0 0 0 0 0 c 0.0 0.0 0 0 0 0 12 Infiltration a 21.2 6.9 20 423 138 24 508 166 13 Subtot Btuh Loss=6+8. ±11 +12 •••• 5715 •••• •••• 4 568 *t*R ss *s ••a •*•s •••• 14 Duet Btuh Loss 0% 0 ••*• 0% 0 t•s* % R*•* o/ *•t* 15 Total Btuh Loss = 13 +14 •••• 5715 •••* *• *• 4 568 t* ** **S► *R*• *88* *551 16 Int. Gains: People @ 300 0 1.1 0 0 **Si 0 Mt *St* Appl. @ 1200 0 •s** 0 0 ***A 0 *55* * **• 17 Subtot RSHGain =7 +8. ±12 +16 sass **ti 5357 •••• •••• 4408 •tt5 t*** *585 *tit 18 Duct Btuh Gain 0% •••• 0 0% •••• 0 % •••• % •••• 19 Total RSHGain =07 +18)•PLF 1.00 •••• 5357 1.00 *••• 4408 •••• •••• 20 CFMArRequired • * ** 292 286 • * *• 233 236 * *•• •►•► LUIS Jobil Printout certified by ACCA to meet all requirements of Manual J Form Zone: Entire House 10'/20/98 MANUAL J: 7th Ed. RIGHT -J: V RIGHT -J WINDOW DATA Job #: Filename LUIS 10/20/98 W S D W G L S S O N A S 0 0 W C W S N K I A L 0 T H V G N H V V H H N H D Y R L A W R A H L G C R R G T A A W L Z E M D G Z L 0 X Y T M R R MASTER BEDROOM 3.0.13 S/N 12034 a n n a c n n d y 3 90 1.0 2.0 2.0 4.0 11.0 12.0 0.0 a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 a n w a c n n n y 3 90 1.0 2.0 1.0 8.0 63.0 24.0 1.9 BATHROOM OPEN AREA a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 BEDROOM 2 a n e a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0 a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 12.0 9.6 BEDROOM 1 a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 18.0 14.4 LIVING ROOM a n s a c n n d y 3 90 1.0 2.0 2.0 6.0 19.0 60.0 32.0 FAMILY ROOM a n n a c n n d y 3 90 1.0 2.0 1.0 8.0 11.0 120 0.0 DINNING ROOM a n s a c n n d y 3 90 1.0 2.0 2.0 6.0 19.0 20.0 10.7 KITCHEN a n s a c n n d y 3 90 1.0 2.0 2.0 4.0 19.0 12.0 9.6 a n w a c n n d y 3 90 1.0 2.0 2.0 4.0 37.0 12.0 0.0