Loading...
WINDOWSPERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date ( `7 Job Address )1 ( f) r t C ) Tax Folio Legal Description Historically Designated: Owner/Lessee / Tenant, L\\ V \''Y\ '1.,( 0 a IL 4'4 C NN1 Owner's Address C 1� °i i1 ' It 1 c ))*\nit, Phone 15 • (.-f C` - Contracting Co. x ) t t(. (t 0 t,1-; `} Address)( 717,3 /VV ' (2- 5 Qualifier`] 1 : 1, ; _ '�t1 i ^C i -S SS #�/ Phone X \ 3 • - 3 2 State #� ll ( C - Q 10:7 Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one : UILDIN r ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Municipal # Competency # Ins. Co. Address Address Square Ft. ; 3 Estimated Cost (value) Yes No Y( Master Permit # S 0 I'il114 -W the of WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be perfonned to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the wovk statell. Signature of owner and/or Condo President owner and/or Condo President 1:1/_&/ .* as t, No My APPROVED: Zoning Mechanical q Date ondo President Owner and/or o ssion Expires. FEES: PERMIT Date OFFICIAL NOTARY SEAL JOSEPH DAVITZ NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC828525 MY COMMISSION EXP. APR. 21 RADON C.C.F. Building Plumbing No My C .sion Expires: OFFICIAL I T i Ain" SEAL ontractor or • JOSEPH DAVITZ NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC828525 MY COMMISSION EXP. APR. 21 NOTARY ontractor or Owner- Builder BOND TOTAL DUE Date , Electrical Structural Engineer r PERMIT NO. ADDRESS: . MIAMI SHORES VILLAGE BUILDING / ZONING DEPARTMENT' SECTION BY DATE ZONING ELECTRICAL MECHANICAL PLUMBING FIRE ' PUBLIC WORKS STRUCTURAL BUILDING OFFICIAL 1. Subf e t to compliance with an Federal, State. Coctttty,Yillage rotes tad reputations. Village tssucnes no responstb(llty for accuracy oflor results train these plans. 2. Thls copy of plans aunt be tuallable cc bulicling site or co inspection Mif be condccta i JOB ADDRESS / N f 7 S I APPLICANT PHONE t# n APPUCATION SHEET OF • MISCELLANEOUS DATE COMMENTS INITIALS CRITIQUE SHEET u ac . • DOORS • SHUTTERS& NAME: 1±,1 A./ i ADDRESS: ( 7 1. (r 01, 47 CITY: tqC ttL IA; hit 1 47 ■ • tvn LLSTATE .j A 1 FT H 1.•-••■• ?"- ti■ • I I e 0 : yr) ;sy h • tg - 4) LW STATE: t ZIP: Impact Laminated: DIAGRAM CONTRACT DATE: CONTRACT NUMBER: / --/ SALESMAN: INSTALLER: DATE OF INSTALLATION: HOME PHONE: ) 7 ( _; OFFICE PHONE: WHITE - OFFICE /YELLOW - CUSTOMER / PINK - SALESMAN MASONERY: r 4 i A )4, i e- Y• 1 Inside Plaster Outside Stucco Operators SILLS: Marble B/N Cerapic Ft/H FINISH: Anod. BRONZE V White Esp. UH Block up Sq. Ft. Bin Blk 4 IN. Blk . DIRECTIONS: '-ti t7 /2-(.L/ 1 •1'' LOOKING: OUTSIDE/IN — FRONT OF HOUSE Non-Impact CUSTOMER SIGNATURE , . ....", .4., Manufacturer: Type Window In: GSD RES. DOOR 9THER / Cmt. 1,/Horz Full Store Alum STYLE: ATW(SV) / SH COL. GSD P.W. F. View Front Door / 2/2 OX 2d2t 3/16 1/1 XO 4d2t 1/4 H.R.S.O. COL. XOX 3d3t H.L.S.O. / Glass Type: /Clear Brz. S/C Grey OBS INSUL. ir Temp. Lexan: MIAMI -DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Security Windows & Doors CONTRACTOR LICENSING SECTION 5100 NW 72 Ave. (305) 375 -2527 FAX (305) 375 -2558 Miami FL 33166 CONTRACTOR ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION Your application for Product Approval of: (305) 375 -2902 FAX (305) 372 -6339 Series 2100Aluminum Single Hung Window under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material inunediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:99-0712_05 Expires:07 /11/2002 Raul Rodriguez Chief Product Control Division THIN IC THE COVERSHEET, SEE A DDITIONAT FrIR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. Approved:08 /26/1999 rancisco Quintana, R.A. Director 1 of 3 Miami -Dade County Building Code Compliance Office Security Windows and Doors 4. INSTALLATION: 4.1 The aluminum single hung window and its components shall be co with the approved drawings. 4.2 Hurricane protection system (shutters): the installation of thi protection system. 2 of 3 ACCEPTANCE No.: 99- 0712.05 APPROVED AUG 2 6 1999 EXPIRES Jule 11, 2002 NOTICE OF ACCEPTANCE SPECIFIC CONDITIONS 1. SCOPE 1.1 This renews the Notice of Acceptance No. 97- 092413, which was issued on July 16, 1998. This approves an aluminum single hung window as described in section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series 2100; Aluminum Single Hung Window, and its components shall be constructed in strict compliance with the following document: Drawing No. W99 -48, titled "Series 2100 Alum. Single Hung Window," Sheet 1 thru 3 of 3, dated 06/16/99, signed and sealed by Humayoun Farooq, P.E., bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3_ LIMITATIONS 3.1 This approval applies to single unit applications of an aluminum single hung window, as shown approved drawings. Man Produ Perez, P.E., Product Con - Control Division 5. LABELING 5.1 Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by two copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified in section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. •1 Examiner Security Windows and Doors ACCEPTANCE No.: 99- 0712.05 APPROVED AUG 2 6 1999 9. This Acceptance contains pages .1, 2, this last page 3. EXPIRES NOTICE OF ACCEPTANCE STANDARD CONDITIONS July 11, 2002 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved. c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The engineer does not need to reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. ZIA d ee Manuel P rez, . E., Product Contro:aminer Product trol Division END OF THIS ACCEPTANCE 3 of 3 1.199 I L 1.350 FRAME HEAD .812 F - 1 .062 L.969J MEETING RAIL F 1.109 I r 1.187 1.637 .062 VENT TOP RAIL L .938 °1 PENT BOTTOM RAIL 2.327 . 062 .937 2.125 5 1 1.387 1.982 1.375 SASH SIDE RAIL 1.250 — 1.375 — 2.125 i FRAME TOP CORNER FRAME BOTTOM CORNER Engr. DR. HU1.4AYOUN FAROOQ STRUCTURES FLA PE (,j 16557 VENT TOP CORNER VENT BOTTOM CORNER APPROVED AS COMPLYING WITH THE SDUT F) ORIDA 8 ILDIN CODE DA BY r, PROW C riOL D1ViS;03 NCE OFFICE COMPLIA BUILDING CODE ACCEPTANCE NC D Uo cc LI o z a0 0 7 Q ^ , Z I o co ►- N Q' D 4 c4 O f o cc a a O cn v U E N w o z n o QrZ > ' I m CD ¢Q 1 O -- Gt+ cn 0 Q ac, e_ F4 w U) I 0 � a zN Q� d w ^mom 0 CA 0 cp z w 0 z J 0 _ o N 0 0 0 U N 0 0 0 0 drawing no. W99 -48 v` J MATERIALS LIST ITEM NO. PART NUMBER QUANTITY DESCRIPTION MATERIAL MANF_ / SUP LIER /REMARKS 1 050 -00 -367 1 HEAD 6063 -T6 ALUMAX 2 050 -00 -375 1 SILL 6063 -T6 TIFTON 3 050 -00 -366 2 JAMB 16063 -T6 ALUMAX 4 050 -00 -164 1 VENT TOP 6063 -T6 TIFTON 5 050 -00 -492 1 VENT BOTTOM 16063 -T6 ALUMAX 6 051 -00 -160 2 VENT SIDE 6063 -T6 TIFTON 7 050 -00 -119 1 MEETING RAIL 6063 -T5 TIFTON 8 - - - - - 9 012 -00 -832 AS REQD. FRAME ASSEMBLY SCREW - # 8 X 3/4" SMS 10 050 -00 -000 AS REQD. VENT ASSEMBLY SCREW - # 8 X 1" SMS 11 047 -00 -008 4 WOOLPILE VENT SIDE - AMESBURY 12 - - - - - 13 050 -00 -000 AS REQD. ACRYUC BASED GLAZING COMPOUND - SCHNEE MOREHEAD 5555 14 007 -10 -016 2 SWEEP LOCK 0 7" FROM ENDS ZAMAK MARBOLLO INTL. 15 004 -00 -003 AS REQD. ROLL FORMED SCREEN FRAME - OPTIONAL 16 048 -00 -002 AS REOD. FIBERGLASS SCREEN MESH - - 17 046 -16 -005 AS REQD. SCREEN MESH ROLL VINYL - - 18 WV -8502 AS REQD. BULB WEATHERSTRIPPING VINYL WIBORG 19 - - - - - 20 WV -2205 1 FLAP SILL VINYL WIBORG 21 046 -16 -030 1/ JAMB BLOCK AND TACKLE BALANCE - WINDOW COMPONENTS 22 2 CLOSED CELL FOAM PAD - 1"X2"X1/4" AT EACH CORNER 23 AS REQD. ROLL FORMED GLAZING BEAD - ALUMINUM 1/2' DRAIN NOTCH AT EACH END OF crR FN RETAINING LEG TYPICAL ANCHORS SEE ELEV. FOR SPACING 0 O B O d d , • a Q V St a O TYPICAL ANCHORS: 3/16 TAPCONS (BY ELCO) OR EQUIV. CONC. ANCHOR HOLDING CURRENT NOTICE OF ACCEPTANCE. INTO 2BY WOOD BUCKS OR WOOD STRUCTURE 1 -3/8" MIN. PENETRATION INTO WOOD THRU 1 BY WOOD BUCKS INTO MASONRY OR DIRECTLY INTO MASONRY 1 -1/4" MIN. EMBED INTO CONC. OR MASONRY SEALANT: ALL FRAME AND VENT CORNERS, AND HEADS OF INSTALLATION SCREWS AT SILL TO BE SEALED WITH WHITE /ALUM COLORED SEALANT, FIXED MEETING RAIL AT ENDS SEALED WITH GE SILICONE. N TYPICAL ANCHORS SEE ELEV. FOR SPACING WOOD BUCKS NOT BY SECURITY WINDOWS, MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. —1 0 1BY OR 2BY WOOD BUCK n Engr. DR. HUMAYOUN FAROOQ STRUCTURES FLA. PE # 16557 VENT WIDTH D.L OPG. EXTERIOR WINDOW WIDTH 1/4' SHIM MAX. (-7 I l TYPICAL ANCHORS _ SEE CHART FOR SPACING APPROVED AS COMPLYING WITH THE SOUTH ORIDA B !LOING CITE 13. . or BY PRODU C 4OL DIVISION BUILD" :G CDE COMPLIANCE OFFICE ' C:. r" 1 A]i Nib. — 0 L -05 O e N C aJ 0 0 z 0 z J 0 0 N rn i 0 U) 0 0 Z_ 2 N T .0 a) O D 0 ) drawing no. W99 -48 DESIGN LOAD CAPACITY - PSF D.L. OPG_ (FIXED) 4. 0 DSB -ANN. GLASS 3/16" -ANN. GLASS WIDTH HEIGHT EXT. 1NT. EXT. 48 1/16" MAX. DESIGN LOAD CAPACITY - PSF SERIES -2100 ALUMINUM SINGLE HUNG WINDOWS (1 OVER 1) WINDOW DIMS. DSB -ANN. GLASS 3/16" -ANN. GLASS WIDTH HEIGHT EXT. 1NT. EXT. 1NT. 19-1/8' 26 -1/2' 37' 53-1/8 26' (3) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 63.3 66.7 80.0 90.1 19-1/8' 26 -1/2' 37' 53-1/8 38 -3/8" (3) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 63.3 66.7 80.0 87.6 61.3 61.0 76.8 61.0 -. 19-1/8" 26-1/2 37' 53-1/8 50 -5/8" (5) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 63.3 66.7 80.0 104.1 50.0 50.0 62.6 62.6 19-1/8" 26 -1/2' 37" 53-1/8 57 _ (5) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 63.3 65.6 80.0 98.3 - - 57.9 57.9 19 -1/8' 26-1/2' 37' 53 -1/8 63" (5) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 58.7 58.7 80.0 89.0 - - 54.5 54.5 19 -1/8" 26 -1/2" 37" - 74-1/4" (6) 63.3 66.7 80.0 121.4 63.3 66.7 80.0 121.4 - - 80.0 89.4 - - 50.0 50.0 a. r z o ND. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. ROLL FORMED ALUM GLAZING BEAD DSB -ANN. GLASS 3/16' ANN. GLASS BEDDING COMPOUND SCHNEE MOREHEAD 5555 GLAZING OPTIONS ROLL FORMED ALUM GLAZING BEAD BEDDING COMPOUND SCHNEE MOREHEAD 5555 53 1/8" MAX. WINDOW WIDTH 49 5/8' MAX. D.L. OPG. (VENT) 50 1/4" MAX. VENT WIDTH TYPICAL ELEVATIONS TESTED UNITS CENTER ANCHOR 0 HEAD & SILL REGD. ON WINDOWS OVER 26 -1/2" WIDE ONLY Engr. DR. HUMAYOUN FARGOQ STRUCTURES FLA. PE f 16557 53 1/8" MAX. WINDOW WIDTH 49 5/8" MAX. D.L OPG. (FIXED) 3/16' ANN. G�A,SS ////2 48 1 /16" MAX. D.L OPG. (VENT) 50 1/4' MAX. VENT WIDTH 0 U 6" MAX. TYP. NOTES; 1. THIS S i KUCTURE IS DESIGNED AS PER THE SOUTH FLORIDA BUILDING CODE 1994 EDITION FOR DADE COUNTY. ALSO FOR WIND LOADS AS PER ASCE 7 -88 USING CORRESPONDING LOADS. 2. WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE StRUCTURE. 3. ANCHORS SHALL BE AS USTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. WINDOWS TO BE PROTECTED WITH DADE COUNTY APPROVED IMPACT RESISTANT SHUTTERS APPROVED AS COMP LYING W THE SOUTH FAORIDA BU�` DIN COD DA �y IASC 9 BY /�/ ,�' PRODU T CONTROL D■V:SON BUILDING CODE COMPLIANCE OFFICE ACCEPTANCE PIG E{ q -01(7 -0 `-- L_JI C fTh c 0 3 0 0 z 3 z w J 0 z 1 J O O N to w EE w v) ) 0 0 J :w • Q c o Q - (V g 3 J Q_ z w O 0 LL1 ° Q c 0 U 0 v 0 0 N ) drawing no. W99 -48 a M I AM 1-DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Security Windows & Doors 5100 NW 72 Ave_ Miami Approved: 06/24 /1999 FL 33166 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375 -2901 FAX (305) 375 -2908 CONTRACTOR LICENSING SECTION (305) 375 -2527 FAX (305) 375 -2558 CONTRACTOR .ENFORCEMENT SECTION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Your application for Product Approval of: Series 2100 Aluminum Fixed Window under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No. :99- 0330.03 Expires:04 /25 /2002 Raul Rodriguez Chief Product Control Division THIS IS THE CO v E RSHE E T , SEE ADDITIONAL PAGES FOR SPEC TFiC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Dade County, Florida under the conditions set forth above. LT,A, rancisco Quintana, R. Director 1 of 3 Miami -Dade County Building Code Compliance Office A Security Aluminum Windows. NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS 1. SCOPE 1.1 This revises and renews the Notice of Acceptance No's. 95- 0929.24 and 95- 0929.26, which waS issued on April 25, 1996. It approves an aluminum fixed window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code, 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION The Aluminum Fixed Window and its components shall be constructed in strict compliance with the following documents: Drawing No.W99 -20, titled "Series -2100 Aluminum Fixed Window" prepared by Al- Farooq Corporation, dated March 22, 1999, sheets 1 and 2 of 2, bearing the Miami - Dade County Product Control Approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division.. These documents shall hereinafter be referred to as the approved drawings. 3. LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 4. INSTALLATION 4.1 The aluminum fixed window approved drawings. 4.2 The installation of this prod ct will require a h ACCEPTANCE No.: 99- 0330.03 2 • APPROVED JUN 1999 EXPIRES : April 25, 2002 is shall be installed in strict compliance with the icane protection system. 5. LABELING Each panel shall bear a pe abel with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. M -1 Perez, P.E., Product ol Examiner Prod t Control Division Security Aluminum Windows. ACCEPTANCE No.: 99- 0330.03 APPROVED 9. This Notice of Acceptance consists of pages 1, 2 and this last page 3. END OF THIS ACCEPTANCE Manuel 'erez, P.E. , Product C JUN 2 zi 1599 EXPIRES : April 25, 2002 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and th original submitted documents, including test - supporting data, engineering documents, are no older than eigl (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and th following statement: "Miami -Dade County Product Control Approval ", or as specifically stated in th. specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if a. There has been a change in the South Florida Building Code affecting the evaluation of this produc and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and /or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. Examiner Security Windows & Doors ACCEPTANCE No.: 98 -0429.06 APPROVED EXPIRES : pp 2 9 2DD2 NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS : APR 2 g 1999 1. SCOPE 1.1 This approves an aluminum horizontal sliding window, as described in Section 2 of this Notice of Acceptance, designed to comply with the South Florida Building Code (SFBC), 1994 Edition for Miami -Dade County, for the locations where the pressure requirements, as determined by SFBC Chapter 23, do not exceed the Design Pressure Rating values indicated in the approved drawings. 2. PRODUCT DESCRIPTION 2.1 The Series 2100 Aluminum Horizontal Sliding Window and its components shall be constructed in strict compliance with the following documents: Drawing No 97 -195, titled "2100 H.R.W.(XOX/XO /0X) — FTL1859/FTL1944" Sheets 1 through 6 of 6, dated 1/6/98, Sheet 6 of 6 with revision 1 dated 4/99, signed and sealed by K. A. Whitfield, P.E., bearing the Miarni -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. These documents shall hereinafter be referred to as the approved drawings. 3_ LIMITATIONS 3.1 This approval applies to single unit applications only, as shown in approved drawings. 3.2 For Design Pressure Rating vs. Window Size, see corresponding comparative analysis table for XOX or XO /OX configuration in approved drawings. 4. INSTALLATION 4.1 The aluminum horizontal sliding window and its components shall be installed in with the approved drawings. 4.2 Hurricane protection system (shutters): the installation of this protection system. 5. LABELING 5.1 i ✓ach unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance 6.1 Duplicate copies of the approved drawings, as identified in Section 2 of this Notice of Acceptance, clearly marked to show the components selected for the proposed installation. 6.1.3 Any other documents required by the Building Official or the South Florida Building Code (SFBC) in order to properly evaluate the installation of this system. MIAMI -0ADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Security Windows & Doors CONTRACTOR LICENSING SECTION 5100 NW 72 Ave. (305) 375-252? FAX (305) 375 -2558 11�Iia FL 33166 CONTRACTOR ENFORCEM ENT SECTION (305) 375 -2966 FAX (305) 375 -2908 Your application for Product Approval of: PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Series 2100 Aluminum Horizontal Sliding Window under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This approval shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. f this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend he use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is ietermined BCCO that this product or material fails to meet the requirements of the South Florida Building :ode. The expense of such testing will be incurred by the manufacturer. kccepta No..: 98-0429_06 Expires:04 /29/2002 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE this application for Product Approval has been reviewed by the BCCO and approved by the Building Code nd Product Review Committee to be used in Dade County, Florida under the conditions set forth above. ?proved: 04/29/1999 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 100 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375 -2901 FAX (305) 375 -2908 ranclsco Quintana, R.A. Director 1 of 3 Miami -Dade County Building Code Compliance Office 0 a 0 0 TYPICAL ANCHORS TYPICAL ANCHORS SEE ELEVS. FOR SPACING 1BY OR 2BY WOOD BUCKS TYPICAL ANCHORS SEE ELEVS. FOR SPACING WOOD BUCKS NOT BY SECURITY WINDOWS, MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. TYPICAL ANCHORS: 3/16" X 2 -3/4" TAPCONS (BY ELCO) OR EQUIV. CONC. ANCHOR HOLDING CURRENT NOTICE OF ACCEPTANCE. 1BY OR 2BY WOOD BUCK It 10 S.M.S. SEE ELEVS. FOR SPACING SEE MULLION APPROVALS FOR MULLION TYPE AND SIZE MATERIALS LIST ITEM NO. 2 3 4 6 PART NUMBER QUANTITY 050 -00 -015 4/ WINDOW 050 -00 -032 4/ WINDOW AS REQD. 8 X 1" 2/ CORNER AS REQD. DESCRIPTION FRAME GLAZING STOP 3/16" X 1/2" GLAZING TAPE BULB VINYL ASSEMBLY SCREWS SETTING BLOCK. 1" LONG MATERIAL ALUMINUM ALUMINUM BUTYL VINYL RIGID VINYL MANF. /SUPLIER /REMARKS 6063 -T5 6063 -T5 1BY OR 2BY WOOD BUCK r - Engr DR_ :MUMAtOUN FAROOQ STRUCTURES FLA PE # 16557 ADHESIVE FOAM TAPE 3/16" ANN. /TEMP. GLASS GLAZING DETAIL MAR 9 Lt 1000 EXTERIOR D.L OPG. WINDOW WIDTH I FRAME CORNER DETAIL FRAME CORNERS SEALED WITH CLEAR COLORED SEALANT. 1/4' SHIN MAX. - 6 _ TYPICAL ANCHORS G SEE ELEVS. FOR SPACING —d• 4. APPROVED AS COMPLY NC WITH THE SOUTH F' RWA BUILDING CODE D A T 19 O 9 BY % t1 PRODUC ! 'TROL DIVIS ;ON BUiLDIPICi CODE COMPLIANCE OFFICE ACCEPTANCE NO 17- 03 -30.03 3 0 3 0 w X z D J O o _ N In w rr w N C vi c 0 a) O ° co ► ': N E-� U f O 0 O cn _ D J N Q I\ z D o O w.- u (0 CO r7 _1 Li 0 a U N a) -, w. 0 0 , C ) p O U 0 0 T .0 u c � drawing no. W99 -20 0 N rn 0) z a 0 0 J • • DESIGN LOAD CAPACITY - PSF WINDOW DIMS. 3/16" ANN. GLASS 3/16" TEMP. GLASS WIDTH LENGTH EXT. ( +) 1NT. ( -) EXT. ( +) 1NT. ( -) 19 - 1/8' 26 -1/2' 3 7' 53 -1/8' 26' 60.0 992 70.0 137.0 60.0 90.6 70.0 137.0 60.0 712 70.0 129.4 60.0 61.1 70.0 1112 19 - 1/8' 26 -1/2' 37' 53 -1/8' 38 -3/8' 60.0 83.6 70.0 137.0 60.0 69.2 70.0 125.8 60.0 62.6 70.0 92.1 48.9 48.9 70.0 88.8 19 -1/8' 26 -1/2' 37' 53 -1/8' 50 -5/8' 60.0 77.4 70.0 137.0 60.0 61.3 70.0 111.6 51.1 51.1 70.0 92.1 - - 70.0 67.3 19 - 1/8' 26 -1/2' 37' 53 -1/8' 57' 60.0 75.4 70.0 137.0 59.0 59.0 70.0 107.3 48.0 48.0 70.0 87.4 - - 70.0 64.2 19 - 1/8' 26 -1/2' 37' 53 -1/8' 63' 60.0 74,0 70.0 134.6 ' 57.3 57.3 70.0 104.3 - - 70.0 83.5 - - 70.0 642 19 -1/8' 26 -1/2' 37' • 74 -1/4' 60.0 72.0 70.0 131.0 55.1 55.1 70.0 100.3 - - 70.0 78.6 24' 36' 48' 60' 72' 24' 60.0 100.0 70.0 137.0 60.0 75.0 70.0 136.4 60.0 66.7 70.0 121.3 60.0 625 70.0 113.7 60.0 60.0 70.0 109.2 24' 36' 48' 60' 72' 36' 60.0 75.0 70.0 136.4 60.0 66.7 70.0 94.7 53.3 - 53.3 70.0 94.7 47.6 47.6 70.0 86.6 - - 70.0 80.9 24' 36' 48' b0' 72' 48' 60.0 66.7 70.0 121.3 53.3 53.3 70.0 94.7 49.5 49.5 70.0 71.0 - - 70.0 71.0 - - 68.2 68.2 24' 36' 48' 60' 60' 60.0 62.5 70.0 113.7 47.6 47.6 70.0 86.6 " - - 70.0 71.0 - - 70.0 56.8 24' 36' 48' 72' 60,0 60.0 70.0 109.2 - - 70,0 80.9 - - 682 68.2' 24' 36' 84' 58.0 58.0 70.0 106.1 - - 70.0 77.2 o e' 50.6 50.6 70.0 104.0 -J NOTE; WIDTH AND LENGTH DIMENSIONS CAN BE ORIENTED VERTICALLY OR HORIZONTALLY AS SHOWN ABOVE. SURFACE APPLIED HUNTINS OPTIONAL d O _1 0 1 1 11 11 ;I / I! it - -!! - • 7 � i f 1 11 J ' I1 -- JL--- JL - - - 11 3/16" ANN. 11 - -w GLASS L J II •I 11 O 12" MAX. AT HEAD /SILL 45 1/8" D.L. OPG. 4.8" WINDOW WIDTH 6" MAX. TYP. AT HUD/SILL CORNERS WINDOWS TO BE PROTECTED WITH DADE COUNTY APPROVED IMPACT RESISTANT SHUTTERS NOTES; 1. THIS STRUCTURE IS DESIGNED AS PER THE SOUTH FLORIDA BUILDING CODE 1994 EDITION FOR DADE COUNTY. ALSO FOR WIND LOADS AS PER ASCE 7 -88 USING CORRESPONDING LOADS. 2. WOOD BUCKS BY OTHERS. MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE STRUCTURE. 3. ANCHORS SHALL BE AS USTED, SPACED AS SHOWN • ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. z >• CD TYPICAL ELEVATIONS TESTED UNITS AN ri r) n A anon 308 Engr DR. HUMAYOUN FAROOQ STRUCTURES FLA. PE # 10557 �- 1.312 --.' .045 TYP. 1.480 GLAZING BEAD 1 1 Ij 1 1 .625 SURFACE APPLIED HUNTINS - OPTIONAL 12" MAX. AT HEAD /SILL 59 1/2" . D.L OPG. 62 3/8" WINDOW WIDTH .5 .375 1.875 .062 TYP. -1.999 WINDOW FRAME 6" MAX. TYP. 3 1.406 AT HEAD /SILL CORNERS APPROVED AS CO!►,PLYINr WITH THF SOUTH F lRiDA BUILDING CODE DAT J/ ut PROD ii{ (INT OL DiV S. BUILDING CODE CO ;c: • ^- - . •CE ACCEPTANCE f4.0.,QQ - x'33 z 0 C4 O U O O C4 Isa z In w O 1- 0 0 0 a_ 'o- tr N 0 z �P' ) O z > ''� co g -cc Q 1 Oa tr N o b z in w N H CO 0, 0 1 N tO 0 0 n X 0 3 0 Li � Z X Z Z j � Q(o <NTT o o _ N � 3 � I , Q`Z CD m Li I U o U) (n Lfl c 0 0) 0 0 0) a, 0 a .0 a, 0 v as a. N 0 0 1 • • o_ 1 >, .0 .0 drawing no. WA4 -2n 0 N 1 0, 0) J z 1 rZ 0 0 Security Windows & Doors ACCEPTANCE No.: 98- 0429.06 APPROVED : APP 2 9 1999 EXPIRES - APR 2 9 20D2 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data engineering documents, are no older than eight (8) years. 2_ Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3_ Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted is no longer practicing the engineering profession_ 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. S_ Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purpose. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages 1, 2 and this 1. t page 3. 4/ , Manue Product .nntr - P.E. Product Cor> Examiner nl flivicinnn (XO OR OX) WINDOWS WITH GLASS DESIGN LOAD CAPACITY 1 /8" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT ( +). INT ( -) HEAD /SILL JAMB s 26 1/2 26 53.3 69.0 2 2 37 53.3 69.0 4 2 53 1/8 53:3 69.0 6 2 37. 38 -3/8 44.0. 94.9 • 37 38 -3/8 53.3 94.9 69.0* 6 53 1/8 53.3 69.0* 6 3 37 50 -5/8 44.0 . 64.1 4 37 53 1/8 53.3- 64.1 4 4 53 1/8 50.0 50.0 6 4 50 -5/8 (X0 OR OX) WINDOWS WITH GLASS DESIGN LOAD CAPACITY 1/8" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT ( +) 44.0 INT ( -) 69.0 HEAD /SILL 2 JAMB 2 26 1/2 . . 26 37 44.0 69.0 4 2 53 •1 /8 44.0 69.0 6 2 37. 38 -3/8 44.0. 94.9 4 3 53 1/8 .44.0 69.0* 6 3 37 50 -5/8 44.0 . 64.1 4 4 53 1/8 44.0 50.0 6 4 SECURI - Y ALUMINUM WINDOWS COMPARATIVE ANALYSIS HORIZONTAL SLIDING WINDOW SERIES 2100 TPDCA E.EVAT ON BASED ON FTL -1944 53 1/8"X50 5/8" 1/8" ANN_ WT P: +6.60psf.(2 "SILL HT.) DP :( + /- )50.Opsf. v NOTES: 1. Exterior design pressures are limited by 6.60psf. water test. 2. Interior design pressures are limited to 2.5 X test D.P. 3. *D.P. limited by glass size BASED ON FTL -1944 53 1/8"X50 5/8" 1/8" ANN_ WTP:±8.00psf.(2 3/8 "SILL HT.) DP:( + /- )50.Opsf. NOTES: 1. Exterior design pressures are limited by 8.O0psf. water test_ 2. Interior design pressures are limited to 2.5 X test D.P. 3. * limited by glass size APPLIED ENGINEERING CONCEPTS, INC P.O. BOX 12 -6403 HIALEAH, FL. 33012 305 - 820 -0550 PPROVED AS COMPLYING WITH THE OUTH FLORIDA BUILDING CODE AT �� , � Zc 19. :�t- Y ". RODli C. ' TRIM. DIV :SION UILD.NG CODE COMPLIANCE OFF CE CCEPTANCC NO. q5-0P-c\ 0 SCALE: 0 Eff 0 LJ 0 0 DATE: 1 -6 -93 DWG. BY:JG I 01 BY_ .If1q tin -07- 1 oG a 0 0 0 -J 0 w z � O (XO OR OX) WINDOWS DESIGN WITH GLASS LOAD CAPACITY 3/16" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT + INT - HEAD SILL JAMB 26 1 2 53.3 110 2 2 37 26 53.3 110 4 2 53 1/8 26 53.3 110 6 2 60 92.3 53.3 110 6 2 74 53.3 96.8 6 2 37 38-3/8 53.3 110 4 3 53 1/8 53.3 110 6 53.3 60 53.3 95.9 6 53.3 74 9 53.3. 73.0 6 _ 53.3 37 8 53.3 92.4 4 64.4* 53 1/8 4 53.3 74.2 6 9 60 50 -5/8 53.3 78.0. 6 .._ d' 74 53.3 60.0 6 4 37 53.3 71.8 4 4 53 1/8 63 50.5 54.3 6 4 60 50.0 50.0 6 4 74 44.0 44.0 6 XOX WINDOWS DESIGN WITH GLASS LOAD CAPACITY 3/16" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT ( +) INT ( -) HEAD /SILL JAMB 74 53.3 110 8 2 85 26 53.3 110 9 2 97 53.3 105.6 9 2 109 53.3 92.3 9 2 74 38 -3/8 53.3 89.2 8 3 85 53.3 87.8 9 3 97 53.3 76.3 9 3 109 53.3 66.8 9 3 74 50 -5/8 _ 53.3 64.4* 8 4 85 53.3 64.4* 9 4 97 53.3 60.1 9 4 109 53.1 53.1 9 4 74 52.4 52.4* 8 4 85 49.8 49.8 9 4 97 63 46.4 46.4 9 4 109 44.0 44.0 9 4 .1 SECURITY ALUMINUM WINDOWS CO M PARATIVE ANALYSIS HORIZONTAL SLIDING WINDOW SERIES 2100 TYPOCA ELEVATION (A) BASED ON FTL -1859 109 5/8 "X63" 3/16" ANN. WTP: +8.00psf.(2 3/8 "SILL HT.) DP:( + /- )44.Opsf_ IOTES: 1_ Exterior design pressures are limited by 8.00psf. water test. 2. Interior design pressures are limited to 2.5 X test D.P. 3. Anchor calculations based on No.10 sheet metal screws. 4. *Design pressure limited by glass size. BASED ON FTL -1859 109 5/8 "X63" 3/16" ANN. WTP: +8.O0psf.(2 3/8 "SILL HT.) DP:( + /- )44.Opsf. NOTES: 1. Exterior design pressures are limited by 6.60psf. water test_ 2. Interior design pressures are limited to 2.5 X test D.P. 3. Anchor calculations based on No.10 sheet metal screws. APPLIED ENGINEERING CONCEPTS, INC P.O. BOX 12 -6403 HIALEAH, FL. 33012 305 - 820 -0550 DAT BY 1 APPROVED AS COMPLYING wa n� SOUTH FLORIDA BUILDING CODE L PRODUCT CGTROL DIV'S.O? BUILDING CODE CONPL.ANCE Di ICE ACCEPTANCE NO z_o4 w 0 U 0 cc U w Q 0 z c DATE:1 -6-98 SCALE:12 =6 LNfG. BY :JG Ct1K BY: JOR NO -97 -195 XOX WINDOWS DESIGN WITH GLASS LOAD CAPACITY 3/16" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT CO INT ( -) HEAD /SILL JAMB 74 26 44.0 110 8 2 85 44.0 44.0 110 9 2 97 26 44.0 105.6 9 2 109 6 44.0 92.3 9 2 6 2 37 38 -3/8 44.0 110 74 38 -3/8 _ . 44.0 89.2 8 3 85 44.0 87.8 9 3 97 44.0 76.3 9 3 109 44.0 66.8 9 3 74 4 44.0 66.4* 8 6 85 60 44.0 66.4* 9 4 97 50 -5/8 44.0 60.1 9 37 109 44.0 44.0 53.1 9 53 1/8 74 54.3 44.0 52.4* 8 rf- 85 63 44.0 49.8 9 97 44.0 44.0 46.4 9 109 44.0 44.0 9 (X0 OR OX) WINDOWS DESIGN WITH GLASS LOAD CAPACITY 3/16" ANNEALED AS SHOWN BELOW -PSF GLASS WINDOW WIDTH (INCHES) WINDOW HEIGHT (INCHES) # of ANCHORS EXT ( +) INT ( -) HEAD /SILL JAMB 26 1/2 26 44.0 110 2 2 37 44.0 110 4 2 53 1/8 44.0 110 6 2 60 44.0 110 6 2 74 44.0 96.8 6 2 37 38 -3/8 44.0 110 4 3 53 1/8 44.0 110 6 3 60 44.0 95.9 6 3 74 44.0 73.0 6 3 37 50 -5/8 44.0 92.4 4 4 53 1/8 44.0 74.2 6 4 60 44.0 78.0 6 4 74 44.0 60.0 6 4 37 44.0 71.8 4 4 53 1/8 44.0 54.3 6 4 60 63 44.0 50.0 6 4 74 44.0 44.0 6 4 SECURITY ALUN INUN WINDOWS COMPARATIVE ANALYSIS HORIZONTAL SLIDING WINDOW SERIES 2100 TYPDCA ELJVATEION (A) BASED ON 7L -1859 109 5/8 "X63" 3/16" ANN_ WTP : +6.60psf. (2 "SILL HT.) DP:( + /- )44.Opsf. )TES: 1. Exterior design pressures are limited by 6.60psf. water test. 2. Interior design pressures are limited to 2.5 X test D.P. 3. Anchor calculations based on No.10 sheet metal screws. BASED ON FTL -1859 109 5/8 "X63" 3/16" ANN. WTP : +6.60psf.(2 "SILL HT.) DP:( + /- )44.Opsf_ NOTES: 1. Exterior design pressures are limited by 6.60psf_ water test. 2. Interior design pressures are limited to 2.5 X test D.P. 3. Anchor calculations based on No.10 sheet metal screws. APPLIED ENGINEERING CONCEPTS, INC P.O. BOX 12 -6403 HIALEAH, FL. 33012 305 - 820 -0550 ROVED AS COMPLYING WITH THE OUTH FLORIDA BUILDING CODE AT Y 19 RODUC' CC 'TROL DIV3S ON UILD:NG CODE COMPLIANCE OFFICE CCEPTA "CE NO - D Li c� 0 U U CC Q 0 DATE: 1 -6 -98 SCALE DWG. HY:JG LJ 0 z tr 0 v: 1 1 1/8' 2 X WOOD BUCK 1/4' MAX_ SHIM 14 511 #1O SHEET METAL SCREW WITH 1 1/2" EMBEDMENT INTO WOOD (TYP.) FRAME VT TH (MAX) CLEAR OPENING —11250 SECTION OF H.R.W. WINDOW 2 X WOOD BUCK 1/4 MAX. SHIM 10 SHEET METAL SCREW Willi 1 1/2" EMBEDMENT INTO WOOD (TYP_) 1 X WOOD BUCK — 3/8' 3/16 DL& TAPCON virrH 1 1/4' EMBEDMEM INTO CONCRETE(TYP.) FRAME VIDTH (MAX.) CLEAR OPENING / 1.63 ( 2 SECTION OF H.R.W. WINDOW SCHNEE MOREHEAD 5555 ADHESIVE BEDDING COMPOUND / 1.3870 1 X W000 BUCK 3/16" DL& TAPCON WM-I 1 1/4" EMBEDMENT INTO CONCRETE(TYP.) 0.3750 GLAZING DETAIL / FULL SCALE .312 GLAZING PENETRATION .0084 ROLLED GLAZING BEAD APPROVED AS COMPLYING WITH T SOUTH FLORIDA BUILDING CODE DAT ' ' t-- .+� 9 FY PRODU CO ?' ROI. C`': S C ^I SU!LD:NG C3 tF COMPLAI'CE OFFIyE ACCEPTAI;Cf viii. O 0 c.� v: C w c DATE:1 -5 -98 SCALE:12 =6' D+HG. BY:JG MATERIALS LIST ITEM NO.. DESCRIPTION ALLOY/TEMP PART NUMBER COMMENTS / MANUFACTURE 1 HEAD 6063 —T6 050 -00 -366 TIFTON 2 SILL 6063 —T5 050 -00 -220 TIFTON 3 JAMB 6063 —T6 050 -00 -367 ALUMAX 4 END RAIL 6063 —T6 050 -00 -102 TIFTON 5 MTG. STILE 6063 —T6 050 -00 -119 ALUMAX 6 VENT T/B RAIL 6063 —T6 051 -00 -160 TIFTON 7 VENT PULL 6063 —T6 051 -00 -165 TIFTON 8 FRAME ASSEMBLY SCREW • #8 X 3/4" PHPH SMS 9 INSTALLATION SCREW SEE PG. 2 10 GLAZING BEAD 004 -00 -008 .0085 ROLL FORM/TIFTON 11 SCREEN FRAME ' 050 -00 -012 TIFTON 12 SCREEN MESH 13 ROLLERS SECURITY 14 SWEEP LOCK SECURTIY 15 BULB VINYL 046 -00 -050 WIBORG 16 FLAT VINYL 046 -00 -017 WIBORG 17 FLAT VINYL 046 -00 -030 WIBORG 18 FLAT VINYL 046 -00 -038 WIBORG 19 SILL ADAPTER 6063 —T6 051 -00 -353 8.0 psf. WATER TEST 2 3/8' ' HT./TIFTON 21 PILE W /FIN SEAL 047 -00 -001 AMESBURY 22 MTG. STILE SCREW 8 X 1 SMS 24 GLASS SEE ELEVATION J 3/8 " 1/8` 3/8" WEEP HOLE FROM ENDS 13 3/4" r` � — 2.1250 2.1240 —7( SECTION OF H.R.W. WINDOW 2/ 2� X P.T. WOOD BUCK OR 1 X P.T. WOOD BUCK SEE JAMB DETAIL FOR ANCHOR SPECIF)CAT)ON y 3/16- DUl TAPCON WITH 1 1 /4" EMBEDMENT INTO CONCRETE [Tr' -) APPROVED AS COMPLYING WIT}; 31x SOUTH FLORIDA BUILDING CODE DA BY PRODU BUILDING CODE COMPLIANCE OF ICE ACCEPTANCE NG. cS TROL DIV:S:ON w 0 In 0 tJ DATE:1 -6-98 SCALE:12 =6" DWG. BY:JG ,CHK. BY: X 0 0 X X � O X Ql CC rn LL1 o‘ O O J C•! Lz W 0 m cD Q Z �rJ to n • 3 p Ov Z 1 3 Y w I- n O Z Z c IL cr 4 23 5/16 VENT D.LO. 53 L8' MAX. FRAME VIDTH // FIX LIGHT — / D.L.O. 0 a N 0 3 L ■ 4 INSTALLATION FASTENERS TYijCAE1,L 33 1/2'1/1- D. VENT X 16 3/4' T'– 10 - 3/4" 1/8" ANNEALED(DSB) ETL# 1944 2100 HORIZONTAL ROLLING WINDOW (Ox / XO) 4- // 3/16" ANNEALED FTL# 1859 2100 HORIZONTAL ROLLING WINDOW (ox / xo / xox) VATON Q 109 3/4" MAX. FRAME WIDTH 16' 5 1/4' - 'YPD CAI • f l I VA` D) D 33 1/4 D.L:D, FIX LIGHT Q 14' INSTALLATION FASTENERS 5 ' X /L 11 i 16 1/2' 1/2" 7 ' 1 3J PROVED AS COMPLYING MTH THE OUTN fLGR!DA BUILDING CODE ODUCT ;T OL DIV!S:CN ILDING CCDE CCMPL!ANCE OFFItgE CEPFANCE NO 1% b LIJ 0 U U 1- 0 WJE: 1 -6 -98 SG1E:12 =3/4 DWG. HY:JG CHI. 6Y: