61 NE 96 St (5)0 HOLD HARMLESS AGREEMENT I am the Owner of the property located at 61 NE 96th Street, Miami Shores, Florida, on or around May 1, 1986, a permit was issued to Sidman's , Inc. to put a new roof on said property. The owner of this roofing company (Sidman's, Inc.) has refused to complete the roofing job that he had agreed to do. The remainder of the job has been re- contracted to another roofing company, Cumberland Roofing. As owner of this property, I hereby release Miami Shores Building Dept. from any possible or potential legal problems and assume all responsibility for any legal action which may result from the issuance of a new permit to Cumberland Roofing Company to complete the roof. DATED: :V ykt, 0-44 Carl A. Davis, Owner 61 NE 96th Street Miami Shores, Florida 33138 ,9v/ $ 7s / / yC MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT F /7 APPLICATION FOR BUILDING PERMIT .Application is hereby made for the approval of the detailed statement ur rrre plans and specifications herewith submitted for the build inc or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miarnt Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not, A copy of approved plans and specifications must be kept at building during progreu of the work. Date..._.__...:—,••- 6�-- _.....__......_.__........ , 19. Ov.ncr's Name and Address .... R• VAR( ( _ No... Street_.... t Registered Architect and /or Engineer ..:.. ......... •<,,, „,.. „.,.,•,,,,,,,, . Name and address of licensed contractor Location yd d Icgal description of lot to be buill on: Lot...... *"r Block Street and Number where work is to be done la. /.../Y .L q c. st• State work to be done pnd purpose of building (by fl New Building Remodeling To be constructed of Kind of foundation Estimated Total cost of improvements $ • Amount of Permit S. Zone cubage required plan Cubage Distance .to next nearest building. Size of Building Lot Disapproved ..' Date.. (Signed) Building Inspector Subdivisionn oors ).. ._... sA � `s_h s 1 Addition FN.. Poo .f.: and for no other purpose. No. of Stories Roof Covering 're . . e.. .. Repairs Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to.. ... / S.S .:.4t1:..8'S/.C.1 11 A , j .L7..... .3./.+5 • The u applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied .c ith the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or noticcs as arc required by the Act. The undersigned agrees to employ only such subcontractors, oq'work to be performed under this permit, as are licensed by Miami Shores Village. Remarks.._ (Signed) STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true.. Permit No..__ .. J. 4 ) /V Date.... )) Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Member a Member Member Member .. .. _.....---- ..._..._. ....._....._ Member �.._._... _.._..... Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained fmin the Planning Board. A re inspection fee of 51.00 will be charged when such re- inspection is made necessary by Improper notice for inspectirm or faulty materials and /or workmanship. i PEI -MIT APPLICATION FOR MIAMI SHORES VILLAGE Date 1 -12-99 Job Address 61 N.E. 96 Street Tax Folio H - O' &Q Legal Description Historically Designated: Yes Owner/Lessee / Tenant Walter M i c h o t Master Permit # Owner's Address 61 N.E. 96 Street Miami Shores Phone 757 -1990 Contracting CoQu alit y Roofing Contractor. Inc. Address 13800 N.W. 1st Avenue Qualifier Carlos Arocho SS# -0382 State # RC 0 5 8 6 2 7 Municipal # Competency # 17889 Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off old roof to wood deck, tin cap 301b. ASTM felt as per cod install galvanized eave drip and valley metals where required, mop on with type III asphalt one layer of 901b. ASTM felt, will install Spanish S Clay Altusa Terracotta tile Colorthru with adhesive setting. $m /l SCrt:`c., oF Cu�k. -L i s0 Square FL ' 2 0 s q. Estimated Cost (value) $ 9,300.00 Afik WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (III' YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating constructibn in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S )bAVIT: I cert that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regu nstruction : - . zoning. Furthermore, I authorize the above -named contractor to do the work stated. ti Signature of owner and/or Condo President FEES: PERMIT LP" Notary as to Owner and/or Co My Commission Expires: RADON 3f'. Date ek 4,. tO.Ar yi irieRN"NDEZ +A • ' *: MY COMMISSIOK sr GC 660474 EXPIRES: Octjtkr 10, 2001 e ti ;! War, : utirc Undersmiters 4/7, %v !o - APPROVED: Zoning Building 1� Mechanical Plumbing Signature of Contractor or Owner - Builder ,I • Notary as to Contrac':r or 2 My Commission Expires: C.C.F. (O ' 0 0 NOTARY - 0 BOND300 TOTAL DUE Electrical No VLOU HERNANDEZ MY COMMISSION R CC 680474 EXPIRES: October 10, 2001 Bonded Thru Notary Public Undetw it. In -3 -, ti Date . Engineering 9983 1064 1999 JUL 01 09:55 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 61 N.E. 9 6 S t met 2. Description of improvement: Reroof to a new tile roof . 3. Owner(s) name and address: Walter Michot x NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF 'FIRST INSPECTION PERMIT NO. TAX FOLIO NO. 1/ - 3.wia -61:3 - / no ° STATE OF FLORIDA: COUNTY OF DADE: LA _ u Interest in property: owner Name and address of fee simple titleholder: N/A 4. Contractor's name and address: Duality Roofing Contractor, Inc. 13800 N.W. 1st Avenue Miami, Florida 33168 5. Surety:(Payment bond required by owner from contractor. if any) Name and address: N/a Amount of bond $ 00 6. Lender's name and address: N/A 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: N/A 8. In addition to himself. Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration d to of this Notice of Commencement: (the expiration date is 1 year from the date of recording.unless a different daft( specified) / ///for/' S1 • nature of Owner Print Owners Name i i} After 14 i de T Sworn to and subscribed before me this .3 day of Notary Public Print Notary's Name My Commission Expires: 61 N.E. 96 Street Miami Shore, Florida 33138 MARYL ZQRNU Z MY COMMISSION It CC 680474 EXP".RES: October 10, 2001 i. Nota Public Underwriters Prepared by: Carlos Arocho Quality Roofing Contractor Address:13800 N.W. 1st Avenue mi 12301.52 2193 Owner's /Agent's Signature Signature 5104 APPENDIX "F" APPENDIX "F "REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern 1 the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. /p 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be d in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually oncealed prior to removing the existing roof system) ) )a 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. pin 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. ti)A 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. I it 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC. din- 7. Ven ilation: Most roof structures should have some ability to vent natural airflow through the interior of the .tructural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. may be b eficial to consider additional venting which can result in extending the service life of tlt'e •of. Date ' Contr %ctor's Signature Contractor's Name: I t .1:4 -1 Roatwr1c, ( Job Address: 69 1 . E q ❑ (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) l2' Re-roofing CATEGORY ❑ (Nail -On Tile) L4Y(Mo , - dhesive Set Tile ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) _ ROOF TYPE ❑ New Roof roofing ❑ Recovering ❑ Repair ❑'Maintenance Flat Roof Area (ft Sloped Roof Area (ft) O S 7 . Total (ft) a2 © S 9, Master Permit No. Exposure category (per ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1): 3- Ft. V A v Deck ATT CHMENT Fastener Type: $PACING Field:. Perimeter: ner: DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS • (Draw details as needed) r r r ROOF PLAN --= -k, -- =--� -- 1 123.01.78 944 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Page -1 Ridge Ventilation? 1 PV 1 saE J RELCHT D E T A I L 3 Appendix "E" UNIFORM RQOFING PERMIT APPLICATION PROCESS No. SL OPED SYSTEM DESCRIPTION Cap Sheets Roo fCovering TILE CALCULATIONS ) (Pmaxl: ` 7�, 3 x71, (Aerod Multiplier): � 1.L1 I ) - M S,35 = M Met° PCA: ( S 0 (Pmax2:111.0 O.. (Aerodynamics Multiplier): 5, .S D - M e :5 -3 a Mr3 32.1 PCA: (Di; Q (Pmax3: ) I.0X7l,(Aerody : 3951)- M aM PCA: Page -2 ac, J cl ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application • 4) Other Component Approvals • ti0 • wETi40-0A0E • PRODUCT CONTROL NOTICE OF . Altusa Tile, Almar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 Your application for Product Approval of: The expense of such testing will be incurred by the manufacturer. .ACCEPTANCE NO.: 96- 1030.03 APPROVED:02 /13/97 EXPIRES: 02/13/00 ACCEPTANCE Altus Tile Nail-On, Mortar Set ar.Adhesive Set One Piece "S" Tile Roofing Tile under Chapter 3 df the Metropolitan Dade County Code governing the use of A Lernate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc. has been recommended for acceptance by the Building Code Compliance Office ro be used in Dade County, Florida under the specific conditions set forth on pages 2 -16 and the standard conditions on page 17. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform' in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. Tne Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the P equirem tints of the S yth Florida Building Code Renews 94 0914.0 ;.METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING Raul Rodriguez Product Control Division Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County B Compliance Office and approved by the Building Code Committee to be use Lin 1?rde County. F conditions set forth above. ding Code under the BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130.1563 (305) 375.2901 FAX (305) 375-2908 INTERNET: mdccOl Oshadow.net PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Altusa Tile Alfareria del Turbio, S.A. 13arquisimcto, Venezuela Category: Sub- Category: Tune: Sub-Type: Product Control No.: 96- 1030.03 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Prepared Roofing Tile ` Nail-on /lNlo. ^,ar Set''Adhcslve Set Clay System Description Alfareria del Turbio, S.A. (Altusa), located in Barquisimeto, Venezuela, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. All tile is manufactured from natural Venezuelan clays. This Product Control Approval relates to A. Itusa's "Altusa S" the profile. Refer to appropriate Product Control Approvals for other tile profiles. The "Altusa S" tile profile is available in a variety of natural clay colors and has matching trim pieces .used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. Optional rubber or clay eave closures are also available. Altusa roof tiles have been tested in compliance with the South Florida Building Code requirements for clay, nail -on, mortar set or adhesive set tile applications. The minimum roof slope for the "Altusa S" nail -on tiles shall be 2 ":12 ". See the "Profile Drawing" ". � Itusa S" profile drawing. Drawing" section in this approval for the P The "Altusa S" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Almar (USA), lnc.,.located in Miami, Florida, is the sole approved importer under contract for sell and distributing Altusa in the South Florida jurisdiction. Contact: Carlos J. Fernandez General Manager Altusa Tile, Almar (USA), Inc. 6645 Northwest 77th Avenue Miami, FL 33166 (305) 471-5830 Product Control Approval Date: Expiration Date: Frank Zuioaga Plans Examiner, Product Division No.: 96- 1030.03 February I3, 1997 February 13, 2000 Test Product Product Dimensions Specifications Description Altusa One Piece "S" • 1 = 13" PA 112 High profile clay roof tile for direct Tile w = 1 " deck or battened nail -on, mortar or ''VI" thick adhesive set applications. Head -lap min. Exposure max. Trim Pieces Product Control No.: 96- 1030.03 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT 1 = varies w = varies PA 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Frank Zuloaga Plans Examiner, Product Control Division SYSTEMS (CONTINUED) Deck Type: .Wood,. Non - insulated Deck Description: New construction 19 / 3 _" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application , . Product Control No.: 96- 1030.03 . Slope Range: ! 2 to 7":! Note: Svstern D is only acceptable in this slope range. For slopes in excess of 7":12", refer to System C. 1 ]ndcrlayrncnt: Roofing Tile: Comments: r 1 Install underlayment system in compliance with Dade County Application Standard PA 120. (Sec System Limitation #5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15 / 3: " plywood is an acceptable substrate. ,I Frank Zuloaga Plans Examiner i•roduci Conzro! Division 4. I IAltusa 'S Tile Tile Profile :';Musa 'S' Tile Tile Profile IAltusa 'S' Tile 1. Quik -Drive Tile Profile Table 3: Attac TILE APPLICATION Battens Direct Deck 1 DATA FOR ATTACHMENT CALCULATIONS Table 1: Aerodynamic Multipliers - X (ft') Batten Ap 0.29 Table 2: Restoring Moments due to Gravity - M, (ft-Ibf) from PA 102 Testing Product Control No.: 96- 1030.03 Direct Deck Application 0.31 3":12" 4":12" or less Battens l Direct Battens I Deck 4.47 i 5.35 I 4.40 1 5.27 Direct I Battens Deck 5 ":12" 4.31 Direct Battens Deck 5.13 I 4.20 6 ":12" Direct Deck 5.03 Battens 4.08 7 ":12" or greater Direct Deck N/A hment Resistance Expressed as a Moment - M (ft-lbf) from PA 102 and PA 102(A) Testing APPROVED NAILS APPROVED' SCREWS 1 nail 12 nails I 1 screw 12 screws N/A I N/A ( N/A 6.20 I 8.40 1 23.70 I 58.20 screws installed in two manufactured holes located 26.80 APPROVED FIELD CLIP WITH: 1 nail 12 nails N/A I N/A 21.20 I 25.30 APPROVED EAVES CLIP WITH: 1 nail N/A 26.90 2 nails N/A 34.90 1' / and 1 5 / 3 " from the head of the tile. Frank Zutoaga Plans Examiner, Product Control Division Table 4: Attachment Resistance Expressed as a Moment - M, (ft -Ibf) from PA 101 Testing Tile Profile Tile Application Attachment -- Resistance Altusa 'S' Tile 1 I Mortar Set 24.50 • Adhesive Set 66.50 4. I IAltusa 'S Tile Tile Profile :';Musa 'S' Tile Tile Profile IAltusa 'S' Tile 1. Quik -Drive Tile Profile Table 3: Attac TILE APPLICATION Battens Direct Deck 1 DATA FOR ATTACHMENT CALCULATIONS Table 1: Aerodynamic Multipliers - X (ft') Batten Ap 0.29 Table 2: Restoring Moments due to Gravity - M, (ft-Ibf) from PA 102 Testing Product Control No.: 96- 1030.03 Direct Deck Application 0.31 3":12" 4":12" or less Battens l Direct Battens I Deck 4.47 i 5.35 I 4.40 1 5.27 Direct I Battens Deck 5 ":12" 4.31 Direct Battens Deck 5.13 I 4.20 6 ":12" Direct Deck 5.03 Battens 4.08 7 ":12" or greater Direct Deck N/A hment Resistance Expressed as a Moment - M (ft-lbf) from PA 102 and PA 102(A) Testing APPROVED NAILS APPROVED' SCREWS 1 nail 12 nails I 1 screw 12 screws N/A I N/A ( N/A 6.20 I 8.40 1 23.70 I 58.20 screws installed in two manufactured holes located 26.80 APPROVED FIELD CLIP WITH: 1 nail 12 nails N/A I N/A 21.20 I 25.30 APPROVED EAVES CLIP WITH: 1 nail N/A 26.90 2 nails N/A 34.90 1' / and 1 5 / 3 " from the head of the tile. Frank Zutoaga Plans Examiner, Product Control Division 10" PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE DOVE TAIL LOCKS 13 1 Fran uloaga Plans Examiner, Product Control Divis cm • Product Control No.: 96- 1030.03 • NAIL HOLE BIRD STOP PROFILE DRAWING ALTUSA "S" CLAY ROOF TILE ACCESSORIES NAIL HOLE I e : , 4. r �� i I � j O n 4 ,..'' "c'`n' " eta. C 8 ! Fran,: uloaga nt,ns Examiner, Product Control Product Control No.: 96- 1030.03 GABLE-RAKE I. The standard minimum roof pitch for Altusa "S" high profile tile shall comply with Dade County Application Standards PA 1 1 3 , PA 119 or PA 120, depending on the method of installation. 2. For nail -on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed holes in the tile. System installation shall be in compliance with the system specifications outlined in this Product Control .Approval. The method of attachment utilized ;!;a l! provide ufficicnt attachment resistance �.A,..e:sscd as a moment to meet or exceed the required moment of resistance determined in compliance with Dade County Protocol PA 115 or PA 1 27.Altu;a "S" Tilt, tile profile has been tested for both wind characteristics and static uplift performance, therefore, attachment calculations for installation in compliance with PA 115 or PA 127 shall be done as a 'Moment Based System'. For mortar or adhesive set tile applications, a field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. For !mortar set tilt applications, 30/90 hot mopped Underlay; ent applications nay be installed perpendicular to the roof pitch unless stated otherwise by the underiayrnent material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section!! of the Uniform Building Permit, a copy of Pioneer's current specifications and details, a copy of this Product Control .Approval and a copy of the Product Control Approval of any Roofing, Component used in the proposed tile application. Reference shall be made to appropriate darn for the required fire rating. S. The applicant shall retain the services of a Dade County certified testing, laboratory to maintain qualiry control in compliance with the South Fiorida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 1 ! 2, Appendix 'A'. SYSTEM LIMITATIONS Product Control No.: 96- 1030.03 Frank auto; 2,r Plans f�xzmim_r Prodic: Control Division Altusa Tile, Alntar (USA), Inc. 6645 Northwest 77th Avenue. Miami Fl 33166 Product Control No.: 96- 1030.03 ACCEPTANCE NO.: 96 - 1030.03 APPROVED : February 13 1997 EXPIRES : February 13, 2000 NOTICE OF ACCEPTANCE STANDARD CONDITIONS I . Rencee•al of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents. are no older than eight (Sj :ears. _. Any and ail approved products .iha!! be pernanent■• labeled with the manufacturer's name. city, state, and :he following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions c: this Acceptance. J. Retteeva!s of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is r.ot in compliance with the code changes; b) The product is no longer the same product (identical) as the one original!,K,approvcd; c) If the Acceptance holder has not complied with all the requirements of this acceptance, • includinst the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) isuse of this Acceptance as an endorsement of any product, for sales. advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If an). portiori of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies. shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. S. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages I through 17. END OF THIS ACCEPTANCE Franc u oaga Plans Examiner, Product Control Division MIAMI SHORES VILLAGE HISTORIC PRESERVATION BOARD APPLICATION FOR A CERTIFICATE OF APPROPRIATENESS NAME OF PROPERTY (if applicable) : ADDRESS OF PROPERTY: 61 N.E. 96 Street NAME(S) OF APPLICANT(S): (NOTE: IF THE APPLICANT IS A PERSON OTHER THAN THE OWNER(S) , EVIDENCE OF THAT PERSON'S AUTHORITY AS AGENT MUST BE ATTACHED TO THE APPLICATION.) TELEPHONE OF APPLICANT(S): (305) 757-1 9 9 0 (305) 1-954-878-1505 ADDRESS OF APPLICANT(S): 61 N.E. 96 Street Miami Shores, Florida 33138 (if different than address of property) PRESENT USE OF PROPERTY: Residential CLASSIFICATION OF WORK FOR WHICH CERTIFICATE IS DESIRED: (circle the letter next to the appropriate classification) please type or print clearly Walter Mirhnt Walter Michot MAINTENANCE OR REPAIR: The act or process of applying measures to sustain the existing fbrm. integrity and material of a building or structure and the existing form or vegetative cover of a site. It may include initial stabilization work where necessary, as well as on -going maintenance and repair. Samples of material must be submitted with the Application. B. RESTORATION: The process of accurately recovering the form and details of a property and its setting as it appeared at a particular period of time by means of the removal of later work or by the replacement of missing earlier work. All applications for restoration shall include site plans (if required by the Building Permit). a statement with bibliography historically justifying the work and any additional photos or information to support the proposed work. C. REHABILITATION: The process o1' returning a property to a state of utility through repair or alteration which makes possi•le an efficient contemporary use while preserving those portions or features of the property which are significant to its historical. architectural and cultural values. All applications for rehabilitation shall include: site plans (if required by Building Permit). and any other supplementary information, such as drawings. that will support the proposed project. D. DEMOLITION: The process of destroying or tearing down a building or structure or a part thereof, or the process of removing or destroying an archeological site or a part thereof. The applicant shall include a report explaining why the proposed action should occur. If this action is to occur for reasons of financial hardship, all pertinent financial data should be included pertaining to the cost of preservation, demolition and new construction. Any other material pertinent to the application is also encouraged as supplementary information. E. NEW CONSTRUCTION: nit prs css of constructing a huilding or structure that has never existed at that location. Applications shall include : a site plan. elevations, floor plan and/or landscape plan. FORM : MSHPB.COA (adopted 4/95) DESCRIPTION OF THE PROPOSED PROJECT (Explain what changes will be made and how they will be accomplished - use continuation sheet if necessary - all applications shall be accompanied by at least one 3" x 5" photograph of the property): Tear off old Spanish S Clay tile roof to wood deck, replace rotted wood, tin cap 301b. ASTM felt, install galvnaized eave drip and valley metals where required, mop on with type III asphalt one layer of 901b. ASTM felt and install Spanish S Clay Altusa Tile with adhesive foam setting. 1(WE) CERTIFY TO THE BEST OF MY (OUR) KNO a E AND BEL THIS APPLICATION AND ITS ATTACHMENTS IS •' UE • ' CO SIGNATURE OF APPLICANT(S): SIGNATURE OF OWNER(S): CERTIFIC • TION FOR BOARD USE ONLY APPLICATION DATE (date application received by Secretary of the Board): DATE: DATE: 7 / ,22/ff DECISION OF THE BOARD (circle the appropriate number): CAPPROVED ilOrtc-X t() e- 0S' S -'+,y le u - 2. APPROVED WITH CONDITIONS (set forth conditions below): bec-C& 3. DENIED SIGNATURE OF CHAIRMAN: ► - DATE: C per' Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) 1 pAr 4e.-w.- D 26 A C.1.1 51 ?4.5g—.1) 2 1 27 • 52 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 10 35 60 11 36 61 12 37 62 13 38 63 14 39 64 15 40 65 16 41 66 17 42 67 18 43 68 19 44 69 20 45 70 21 46 71 22 47 72 23 48 73 24 1 49 74 25 50 75 Du Quesne & Associates, Inc. Consulting Engineers Testing Laboratory ON -SITE CONCENTRATED UPUFT LOAD TESTING OF ROOF TILE IN ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 Owner's Name: \'AJAN NA 1 ( c Job Address 6 I N, E. ', • NA1X1,1t S4'Oe.E4 Roofing Contractor A ■ Y 'Roo v" L P- II * � Type of Tile: .-- CA‹ - VE - � T Date Installed 1 2-- 4 � 0 'gyp© -�� Approximate Roof Height: 24 feet Roof Pitch 31 l z Type of Access to Roof: Scaffolds )- Ladder Other Approximate Square Footage of Roof: % 20 m ft 2 Required Testing Force: 35 lbs. Testing Equipment: Chatillion DFIS 100 Date Tested 2.11 ' O 0 rge Du Quesne, 1 Engineer . #24513 Du Quesne & Ass • gates, Inc. E.B. License c , , 5245 Lab Certification #94- 0318.01 SITE SPECIFIC INFORMATION TEST RESULTS P = PASS, F = FAIL SKETCH OF ROOF IN BACK UTR 16721 Environmental • Civil • Structural Building Inspection Services Permit #. 4 7 2 51 IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS PA 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7815 S.W. 24th Street • Suite 109 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 JOB SHEET NO. CALCULATED BY CHECKED BY OF DATE KETCH OF ROOF 1, e► E1 5 1 te elimilleimigar =NMI eir ECU i a g O ` Z3 14` 4 NOTES' JOB 14E Si. 1 --Cs SHEET NO '9F CALCULATED BY CHECKED BY DATE SCALE DATE