Loading...
ROOFINGBUILDING ELECTRICAL PLUMBING iOOFING Owner of uilding MIAMI SHORES VILLAGE. FLORIDA ❑ DATE `" 195 ❑ PERMIT N° 7056 Contractor's License No. a "rchitect contractor __ y / , 31. Builder .egal Lot Description "ddress of wilding Work to be performed under this Permit Value of Project $ Subdi- vision Amount of Signed . , BY INSPECTOR Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application ierefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans irawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any ime if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is 3ranted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations ?ertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and. that he assumes responsibility for work lone by his agents, servants or employees. BY AUTHORITY In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations ?ertaining thereto and in strict ormi with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- -epting this 'permit I assume esponsibili for all work done by either, myself, my agent, servant or employee. • j t 7��o CONTRACTOR OR BUILDER 7 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 7 -25 -97 Job Address 857 N:E. 97 Street TaxFolio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant Mark Orlandp Master Permit # 1 8 Z-1 Owner's Address 857 N.E. 97 Street Miami Shores, Fla.Phone 759 -0876 ContractingCcQuality Roofing Contractor, Inc. Address 251 N.W. 99th Street Qualifier Carlos Arocho SS# Phone 751-0382 State # RC 0 0 5 8 6 2 7 Municipal # Competency # 17889 Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION Tear off old roof to wood deck, tin cap 301b. ASTM felt as per code, install eave drip and valley metals where required, mop on with type III asphalt one layer of 901b. ASTM felt , install Spanish S White Colorthru Tile adhsive set. Square Ft. 31 s q . Estimated Cost (value) $11,000.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of-all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable ±n regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Au/lV�.�c� 6.— G P 02 -V .igitature of owner and/or Condo President Date Signature of Contractor or Owner - Builder Date A AA MAR ' t NDEZ t _ MY COMMISSION # CC 324212 EXPIRES: October 10, 1997 Bonded Thni Notary Public Undeiv itera Notary as to Ov ■ er r and/or My Commission Expires: FEES: PERMIT q S. RADON APPROVED: Zoning Mechanical Building or o: • _�. NANDEZ Notary as to Contr My Commission Expires; YLOU := MY COMMISSION 11 CC 324212 a• EXPIRES: October 10, 1997 p; ..'. Bonded Nu Notary Pub: c Underwriters to m O C.C.F. G C7 2. NOTARY BOND 3 O TOTAL DUE 3 Electrical Plumbing Engineering l Contractor's Name:QtalA../ Roo(`r c e0, cat — C Job Address: ROOF CATEGORY ❑ (Low Slope Application) ❑ (Nail -On Tile) l# (Mortar- Adhesive Set Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ,�,__ ROOF TYPE ❑ New Roof LM'Re roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (11 Sloped Roof Area (ft 2 ) ` S c . Total (ft 3 1 s . Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7 -88 table 1): Ft. V Ft. V A Deck type: (A)on L l ¥ (p ATTACHMENT 1 Fastener Type: I � s r �G �lVi.v L r,c�‘ S SPACING tr 11 / fr Field: p .C,. Perimeter: (p D.C. . Corner:lo 123.01.78 9/96 DETAIL 1 & 2 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) 3$ .0 . Page -1 r 8S) k), . qr? sT 4 ROOF PLAN Ridge Ventilation? MEAN HEIGHT lL l Deck type: hoot. 11C to Underlayment: Insul D E T A I L 3 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. SLOPED SYSTEM DESCRIPTION 3o1b, A-sra� tion: 12" ROOF SLOPE Fastener type & spacing: Cap Sheet: Roof Covering: Page -2 Drip edge: eave dr r -:Lt3. ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals r o.t. F. �/d 4,/, .G / fS re) s .11"7 ef` rs TILE CALCULATIONS (Pmaxl: . 3 x a, (Aerodynamic Multiplier):2,1 .� I ) - M 7. ,0 = M 1 ' . 3 I PCA: ( .50 (Pm ax2 :I D3.7 x X (Aerodynamic Multiplier):32..) ) - M 1. I 0 = M rz : a$.o PCA: 619 S� (Pmax3: 103 27 X a (Aerodynamic Multiplier):3) • )Li ) - M .1 D = M PCA: 6 (0•5'° 9 • ,R i.1ETR0•DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Metro Roof Tile, Inc. 11350 N.W. South River Drive Miami, FL 33178 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Your application for Product Approval of: Spanish S under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Enginering, Inc., and Tesiwell Craig Laboratories & Consultants, Inc. has been recommended for acceptance by the Building Code Compliance office to be used in Dade County, Florida under the specific conditions set forth on pages 2 et. seq. and the Standard Conditions on page 3. This approval shall not be valid after the expiration date stated below. The Office of Code Compliance reserves the right to secure this product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The applicant shall re- evaluate this product or material should any ammendments to the Soutli Florida Building Code be enacted affecting this product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.:94- 1017.01 Expires:06 /15/98 THIS_ IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. • Approved:06 /15/95 -1- Ape Rau to• . Iguez / Product Control Supervisor anger, Director Building Code Compliance Dept. Metropolitan Dade County Applicant: Metro Roof Tile, Inc. 11501 Northwest 117th Way Medley, Florida 33178 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Prepared Roofing Sub - Category: High Profile Tile T Nail - on/Mortar Set/Adhesive Set u b - Type: Concrete System Description Contact: Fernando Arias Metro Roof Tile, Inc. 11501 Northwest 117th Way . Miami, FL 33178 (305) 558 -6712 2 Product Control No.: 94- 1017.01 JUN 1 5 1995 JUN 1 5 1998 Approval Date: Expiration Date: Metro Roof Tile, Inc., located in Medley, Florida, manufacturers clay roof tile for nail -on, mortar set or adhesive set applications. This Product Control Approval relates to Metro Roof Tile's "Spanish S" high tile profile. Refer to appropriate Product Control Approvals for other tile profiles. The Metro Roof Tile "Spanish S" tile profile is available in a variety of colors and has matching trim pieces used for rake hip, ridge hip, and valley terminations. These accessories are manufactured for all profiles and form a part of this Product Control Approval. The Metro Roof Tile "Spanish S" roof tile has been tested in compliance with the South Florida Building Code requirements for concrete, nail -on, mortar set or adhesive set tile applications. See the "Profile Drawing" section in this .Approval for the Metro Roof Tile "Spanish S" profile drawing. The Metro Roof. Tile "Spanish S" profile has been tested for both wind characteristics and static uplift performance, therefore, any consideration for installation shall be done as a 'Moment Based System'. Data for attachment calculations is noted in Tables 1 through 4 of this Approval. Raul Rodriguez s .. Product Control No.: 94- 1017.01 Trim Pieces TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions S pecifications Description Spanish 'S' Concrete 1= 18" PA 112 High profile, interlocking, one - piece, Roof Tile w = I0%" 'S' shaped, concrete roof tile equipped 'A" thick with two nail holes and a single roll. For nail -on, mortar set and adhesive set applications. I= varies w = varies varying thickness PA 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 3 / 1 (7//C) Raul Rodriguez Product tt30 Felt tt43 Coated Base Sheet Mineral Surface Cap Sheet Dimenng N/A N/A N/A Lenzingtex - ZB 140 59" x 164' roll Underlayment 22 lbs/roll Rainproof 11 Ice and Wat Shield Mopping Asphalt Flashing Cement TRADE NAMES. OF PRODUCTS MANUFACTURED OTHERS 30" x 75' roll 36" x 75' roll or 60" x 75' roll 36" x 75' roll N/A N/A Test Specifications ASTM D 226 type 11 ASTM D 2626 ASTM D 249 PA 104 PA 104 PA 103 ASTM D 312 type III or IV ASTM D 4586 4 Raul Rodriguez Product Control No.: 94 Product Description Saturated organic felt to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. Single ply, nail -on underlayment. Single ply, nail -on underlayment with 2" self - adhering top edge. Self- adhering underlayment for use as a top ply in a two ply underlayment system with Approved 1130 or 1143 as the base layer. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply underlayment system. Cut back, asphalt based, asbestos free, fiber reinforced, trowel grade cement for repair and flashing applications. Manufacturer generic generic generic Lenzing Performance, Inc. with current PCA Protect -O -Wrap, Inc. with current PCA W.R. Grace Co. with current PCA generic generic Roofing Nails Tin Caps Wood Battens Tile Nails Tile Screws Roof Tile Adhesive ( "Polypro® AFI I60 ") Test Product Product D imensIons $perifirationq Description Manufacturer Asphalt Primer N/A ASTM D 41 Cut back, asphalt generic based coating used to facilitate bonding of dissimilar materials. min. 12 ga. with '/," head min. 32 ga. min. 1'/," o.d. max. 2" o.d. horizontal min. 1" x 4" for use with vertical battens or min. 1" x 2" for use alone min. 8d x 2W' or min. 10dx3" #8 x 2%3" long 0.335" head dia. 0.131" shank dia. 0.175" screw thread diameter PA 114 Appendix E PA 114 Appendix E vertical Wood Preservers Salt pressure treated min. 1" x 4" Institute LP - 2 or decay resistant lumber battens PA 114 Appendix E PA 114 Appendix E 5 Raul Rodriguez Product Control No.: 94- 1017.01 Annular ring shank, hot dipped, electro or mechanically galv. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment Corrosion resistant, screw, smooth or annular ring shank nails. Corrosion resistant, coated, coarse thread wood screws. generic generic generic generic generic Roof Tile Mortar N/A PA 123 Prepared mortar mix Bermuda Roof ( "TileTiteT^t ") designed for mortar Company, Inc. set roof tile with current PCA applications. N/A See PCA Two component Polyfoam Products, polyurethane adhesive Inc. designed for adhesive with current PCA set roof tile applications. Product Hurricane Clip & Fasteners Valley Flashing Drip Edge Dimensions rIPA min. %a width Min. 0.060" thick flip Fastener min. 8d x 11/4" min. 26 ga. min. 16" width min. 26 ga. min. 2" face flange min. 2" deck flange Test Specifications PA 114 Appendix E ASTM A 525 PA 111 6 Raul Rodriguez Product Control No.: 94 1017.01 Product Description j Manufacturer Corrosion resistant generic bronze, aluminum, stainless steel, galvanized steel or plastic attachment clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. Galvanized steel valley flashing Galvanized steel drip edge generic generic Test Agency Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied . Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Testwcll Craig Laboratories & Consultants, Inc. Test Identifier 7161 -03 Appendix 111 7161 -03 Appendix 111 TEST REPORTS 25- 7200.1 94 -084 94 -083 7161 -03 Appendix 11 Report Dated Aug. 1, 1994 P0647 -0I PO402 Project No. 307025 Test #MDC -78 Lab #EA -25 Tech: 0. Suarez 7 Static Uplift Testing Feb. 1 995 PA 102 (Quik -Drive Screws, Battens) Withdrawal Resistance Testing of screw vs. smooth shank nails Raul Rodriguez Product Control No.: 94 -10 7.01 Test Naine /Report J2ni� Static Uplift Testing Dec. 1991 PA 102 Static Uplift Testing Dec. 1991 PA 102(A) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Wind Driven Rain PA.I00 Physical Properties I'A 112 May 1994 April 1994 Dec. 1991 Aug. 1994 Aug. 1994 Sept. 1993 Oct. 1994 July 1994 Underlaymeut: Roofing Tile: Comments: SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 7 32 " or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Note: System D is only acceptable in this slope range. Product Control No.: 94 1017.01 Install underlayment system in compliance with Dade County Application Standard PA 120. (See System Limitation #5.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, "/„" plywood is an acceptable substrate. 11 Raul Rodriguez