Loading...
755 NE 97 St (7)Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build - ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address ...t1.t.1.‘4..F:.2P..2Z2 .L.81 D sass No. ..L7. Street.. .7 ... Registered Architect and /or Engineer Name and address of licensed contractor 'L d l.L)L.D.. .L / . /Y ......._...._ Location and legal description of lot to be built on: �t Lot ¥ / r - Block 7. 0 Subdivision .C3. ',it Cr._ _ /A` 5 - Street and Number where work is to be done 7s}..sr __.- 1.Y.., 9 7 .. State work to be done and purpose of building (by floors)._- _._,it) 6 & X A x E ...._._ 4. --Van - 6' b./ T cd c N G L. E 7 c- t - - / - 3e:. f�"L y_ j - -ia 42 T fc_69 7 _ ?9t,C New Bui!cing Remodeling................_... Addition Repairs No. of Stories _ To be. constructed of Kind of foundation Roof Covering .............._...._ Estimated Total cost of improvements $.. / . .Q Amount of Permit $. / d Zone cubage required flan Cubage Distance to next nearest building.. Size of Budding Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcoQtractors, on work to be performed under this pennit, as are licensed by Miami Shores Village. 1 �� a lJ Remarks (Signed) —7? STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No.. Date 2 ? . r Read, Sworn to and Subscribed before me. Disapproved (Signed) Building Inspector MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT BUILDING INSPECTION DEPARTMENT Chairman Member Member Council Approved ANNING BOARD DATE and for no other purpose. Notary Public, State of Florida My Commission Expires to me well known, Mcmbcr Member Member Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning hoard. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for insprctirm or faulty materials and /or workmanship. Date 1 I t ' 1 Job ddre s 5 5 M. E q7 s� Tax Folio 1 o�t / 7 a 0 j Leal Description S C2 G ) D "E Historically Designated: Yes No ,)c ROIAN to ,�,hr J %3 Master Permit # 5n 0 ql Owner's Address 1 -55 A7 . e. q"7 Phone 3 Ds — 7 a 1 - 76, 5R Contracting Co. A. PAkon E Pk t°'S Cnf 7.3 (, try c. Address Lr 1 6 6 5 C,v , 70 G - Qualifier A dv O E()J X.) - LA., , ? Phone ?)p 5 - 664 - `t q o State # (C 006"1 aQg Municipal # 30 3 3 9 f .g - 3 Competency # (c 4 Q 8,p0a 5 Co. LA'CC • A,n p✓A cG v■ EV Owner/Lessee / Tenant Architect/Engineer Bonding Company Mortgagor Square Ft. Signature of o FEES: PERMIT PERMIT APPLICATION FOR MIAMI SHORES VILLAGE 0 74 A�JA- dU PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION tf)A ( Lik.) I\.Q Permit Type (circle one): BUILDING ELECTRICAL UckiLk SG N f-e` WARNING TO OWNIE i : YOU MUST RECORD ' OTICE OF ENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEME '1'S 1 YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOU "': LENDE' OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction an, �► g. urthermore, I authorize the above -named contracto r to the work stated. 1 an . or Con . o Pre • ■••••e LOREN BECKELHEIMER COMMuION 1 CC876499 EXPIRES � 0 2003 ADVANTAGE NOTARY • • • ; 4 • 4 dent I.' ary as to Owner and/or Condo President My Commission Ex, Tres: RADON Date Date C.C.F. Address Address Address My Co Co/DR / (G 1 '" Signature ntractor or Owner- Builder Date Neas to Contractor or Owner- Builder LOREN BECKELHEIMER or • COMMISSION # CC876499 n EXPIRES OCT 04, 2003 • BANDED THROUGH • ADVANTAGE NOTARY NOTARY " BOND � TOTAL DUE Date APPROVED: Zoning Building � Electrical Mechanical Plumbing Engineering NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME -OF FIRST INSPECTI PERMIT NO. STATE OF FLORIDA COUNTY Or DADE- r , 1R.564896 2001 OCT 15 11:27 THE UNDERSIGNED hereby gives notice that improvements will be mado to certain real property. and In accordahce with Chapter 713, Florida Statutes. tho following information Is provided In thls Notice of Commencement. • 1. Legal description of property and street address: 2. Description of improvement: 3. Owner(s) name and address: J Interest in property: Name and address of fee simple titleholder. 4. Contractor's. name and address: A. QO.(,/1 c p RrigAit� ` i 1 5 6 Sr v 70 c-4 ci 1r_ 5. Surety: (Payment bond required by owner from c if any) Name and address: / . 1,-) P Amount of bond: $ �/ .q 6. Lender's name and address: k/A 7. Persons within the State•of Florida designated by Owner upon whom.ilotices or other documentt may be sdrved as provided by Section 713.13(1)(a)7., Florida Statutes. Name and address: .8. In addition to himself, Owner designates the following persons) •(o receive a copy of the Uenor's Notice as pro- vided in Section 713.13(1)(b). Florida Statutes. • ti • Name and address: • Signature of Owner Print Owner's Name Notary Public Print Notary's Name My Commission Exp•. WI HAR By TAX FOLIO NO. ,AA t AAA l I ,\r)r -P`} CU )07A- 9. Expiration date of this Notice of Commencement (the expire ion date Is•1 year from the date of recording unless a different • . e in specifie. 1 All. KO -Th � (^) C 61..! Sworn to and subscribed before me this � day of® F FLORIDA, COUNTY OF DADE CERTIFY that this is a truero s office on he _ day of , A I) 2020 al Seal. unty Courts C. Prepared by AiunRc:t. PAim Address.. 4 1 6 1 Contractor's Name: p1 t-Mett ROOF CATEGORY ❑ (Nail -On Tile) (Mortar- Adhesive Set Tile) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof (Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance ❑ (LowlSlope Application) r' (Asphalt/Fiberglass.'S 1 Job Address: 17..c i1/43,L 9 S7 Flat Roof Area (f0) Sloped Roof Area (ft') 3 r Od Total (ft') 3400 Master Permit No. Exposure category (p ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1): 1 Ft. d Ft. A v Deck type: ).1., "rd. (7" Fastener Type: ATTACHMENT 1� I. n�s�A SPACING Field: Perimeter: (.p Corner: DETAIL 1 & 2 Appendix- "E" UNIFORM ROOFING PERMIT'APPLICATION PROCESS No. ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) ROOF PLAN 1 Deck type: z Underlayment: Insulation: Ridge Vontlbllon? 1 Fastener type & ,paring: Cap Sheet: MEAN HEIGHT 15 to Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 11 ROOF ILOPZ D E T A I L 3 (Pmaxl. X X (Aerodynamic Multiplier): — Id. ) . s anq (Pmax2, ° W ' X A (Aerodytu Multiplier): �(Q 1 ) { yruiltlic . (Pm ° %'x Aerod do ultiplier): �� 1p 1 - SLOPED SYSTEM DESCRIPTION Roof Covering: S 4 1 to3 Pc - T e trrt:& Co+ TILE CALCULATIONS M -e-'. �1 = ry , ��j • PCA: Wt 4\-8_1 5 1/C- M C- = M:`' PCA: �{ • 9 M S' M - 1)• t PCA: (0(- ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) r'ade County Product Control Notice of Acceptance•Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals roam • . • MIAMI -DADE PRODUCT CONTROL NOTICE OF ACCEPTANCE Santa Fc Tile Corporation 10302 N.W. South River Drive, Bay #16 Medley ,FL 33178 • Your'application for Notice of Acceptance (NOA) of: Spanish "S" Clay Tile under Chapter 3 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Constru tion, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at any time from a jobsite or manufactury:r's plant for quality control testing. If this product or material fails to perform in the approved manner, ICCO may revoke, modify, or suspend the use of such product or material immediately. BCCO reseris the right to revoke. this approval. if it is determined by BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturt;r. ACCEPTANCE NO.: 00- 1212.06 EXPIRES: 02/01/2006 • THIS IS THE COVERSHEET, SEF. ADDITIONAL PA(. ES FOR SPECIFIC AND GENRR.kL CONDITIONS BUILDING CODE & PRODUCT REV'IIE\v COMMITTEE This application for Product Approval has been reviewed b tke BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dride County, Florida under the conditions set forth above. APPROVED: 02/01/2001 rit acceptance cower pag .4ot Internet mail address: postmaster @builelingcodeonline.com Note: MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE. METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAl\.n. FLORIDA 33130.1563 (305) 375 -2901 FAX (305) 375.2905 CONTRACTOR LICENSING SECTION (305) 375 -2527 FAX (305)375-255S CONTRACTOR ENFORC1 ME r DIVISION (305) 375.2966 FAX (305) 375.290s I'RODUCr CONTROL DIVISION (305) 375.2902 FAX (305) 372.x,)39 Phone: Raul Rodri2,uez Chief Product Control Division Francisco J. Quintana, R.A. Director Miami -Dade County Building Code Compliance Office j (QUICK FisJCSLificonitoe To: FW 3C�;S • bbj - S 1 6 PhoneC JINap SANTAFE TILE CORPORATION NOTICE OF ACCEPTANCE STANDAIi D CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after renewal application has been filed and the original submitted documentation, including test supporting dat engineering documents, arc no older than eight (8) years. 2 Any and all approved products shall be permanently labeled witf the following statement: "Miami -Dade County Product Control specifir:conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Co affecting the evaluation of this product and the product is not in compliance with the code changes;'',, bl The product is no longer the same product (identical) as , one originally approved; c) if the Acceptance holder has not complied with all the regtr'Jremcnts of this acceptance, including the correct installation of the product; II d) The engineer who originally prepared, signed and sealed t.lil required documentation initially submitted, is no longer practicing the engineering professtan. 4 Any revision or change in the materials, use, and/or manufacture- of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through thc filing cf a revision application with appropriate fee and granted by this office. • 5 Any of the following shall also be grounds for removal of this A'ccptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any prot�uct, for sales, advertising or any other purposes. the manufacturer's name, city, state, and Approved". or as specifically stated in the 6 The Notice of Acceptance number preceded by the words Miami) -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If an!, portion of thc Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and otliLr documents, where it applies, shall be provided to the user by the manufacturer or its distributors and Sh all be available for inspection at the job site at all times. The copies need not be resealed by the enginect. 8 Failure to comply with any section of this Acceptance shall be ci for termination and removal of Acceptance. , - 9 This Acceptance contains pages t through 5 1 END OF THIS ACCEPTA;kICE ACCEPTANCE No.: 00- 1212.06 Frank Zuloaga, Roofing Product Control Examiner SANTAFE TILE CORPORATION 5. LABELING 5.1 All tiles shall bear the imprint or identifiable m king of the manufacturer's name or logo, or following statement; "Miami -Dade County Pr duct Control Approved". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accomp ied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Buildng Official or applicable Building Code in order to properly evaluate the installation of this system. PROFILE DRAWIN SANTAFt "SANTAFE S" CLAY ' OOF TILE ACCEPTANCE No.: 00- 1212.06 Frank Zuloaga, RRC Roofing Product Ci"sntroi Examiner SANTAFE TELE CORPORATION 4. INSTALLATION 4.1.1 Santafe 'S' and its components shall be installed xi strict compliance with Miami Dade County Roofing Application Standard RAS 118 RAS 119, and RAS 120. 4.1 For Attachment Calculations Santafe 'S' Tile Profile Santafe 'S' Tile Profile Santafe S 3.5 30/90 hot mopped underlayment applications rr slope unless stated otherwise by the underla' literature. 3.6 This acceptance is for wood deck applications. compliance with applicable building code. Table 1: Aerodynamic Multip Tile ?. (ft Profile Batten A• •lica Tile Applicati on Direct Deck 21.8 • Battens 3 0.274 Table 2: Restoring Moments due toravity - M (ft -Ibf) 2 ":12" 3 ":12" 4 ":12" I r:12" 6 ":12" • 7 or il greater Battens! Direct Battens Direct Battens Direct Bat Direct Battens] Direct Battens 1 Direct t Deck Deck Deck Deck i Deck Deck 5.93 1 5.90 5.85 i 5.82 1 5.73 5.69 I 5;56 1 5.53 5.32 J 5.29 5.03 I N, A i il Table 3: Attachment Resistance Expressed a a Moment- Mf (ft-lbf) For Nail -On Systen, Two Nails One Screw Two Screws One Screw I Two Screws w/ Cli. w/ Cli 29.16 ± 38.28 57.31 I 57.60 61.77' I.` Approved screws as noted 'Product manufactured by others' ACCEPTANCE No.: 00- 1212.06 ay be installed perpendicular to the roof mcnt material manufacturers published Minimum deck requirements shall be in ers— X(ft ') ion X (ft Direct Deck 0.297 rank Zuloaga, RAC Roofing Product Control E•arniner Table 4: Attachment Resistance Expressed for Mortar or Adhesive Se as a Moment - Mr (ft -lbf) Systems Tile Profile • Tile Application 1 Attachment Resistance Santafe 'S' Mortar Set 23.6 Adhesive Set i 61.9 SANTAFE TELE CORPORATION 4. INSTALLATION 4.1.1 Santafe 'S' and its components shall be installed xi strict compliance with Miami Dade County Roofing Application Standard RAS 118 RAS 119, and RAS 120. 4.1 For Attachment Calculations Santafe 'S' Tile Profile Santafe 'S' Tile Profile Santafe S 3.5 30/90 hot mopped underlayment applications rr slope unless stated otherwise by the underla' literature. 3.6 This acceptance is for wood deck applications. compliance with applicable building code. Table 1: Aerodynamic Multip Tile ?. (ft Profile Batten A• •lica Tile Applicati on Direct Deck 21.8 • Battens 3 0.274 Table 2: Restoring Moments due toravity - M (ft -Ibf) 2 ":12" 3 ":12" 4 ":12" I r:12" 6 ":12" • 7 or il greater Battens! Direct Battens Direct Battens Direct Bat Direct Battens] Direct Battens 1 Direct t Deck Deck Deck Deck i Deck Deck 5.93 1 5.90 5.85 i 5.82 1 5.73 5.69 I 5;56 1 5.53 5.32 J 5.29 5.03 I N, A i il Table 3: Attachment Resistance Expressed a a Moment- Mf (ft-lbf) For Nail -On Systen, Two Nails One Screw Two Screws One Screw I Two Screws w/ Cli. w/ Cli 29.16 ± 38.28 57.31 I 57.60 61.77' I.` Approved screws as noted 'Product manufactured by others' ACCEPTANCE No.: 00- 1212.06 ay be installed perpendicular to the roof mcnt material manufacturers published Minimum deck requirements shall be in ers— X(ft ') ion X (ft Direct Deck 0.297 rank Zuloaga, RAC Roofing Product Control E•arniner ROOFING ASSEMBLY APPROVAL :ll'e°o ry; Roofing Sub Cateaorv: 07320 Roofing Tiles Materials Deck Type: 1. SANTAFE TILE CORPORATION SCOPE This renews a roofing system using Santa Fe "Santafe Santafe Tile Corporation described in Section 2 of this y comply with the South Florida Building Code, 1994 Ed 1 locations where the design pressure requirements, as de does not exceed the design pressure values obtain by ca using the values listed in herein. The anachment calcul system. • PRODUCT DESCRIPTION Vf:,nufactured by Applicant Santafe `S' Clay Roof Tile Trite Pieces Clay Roof Tiles Wood Test Dimensions Specifications 1= 18" w= 11.5" v: thick 1= varies w = varies varying thickness PA I1? 2 CCEPTANCE No.: 00- 1212.06 Approval Date: February 1, 2001 Expiration Date: February 1. 2006 • " clay rooting tile, manufactured by otice of Acceptance. designed to on for Miami -Dade County. For rmined by applicable building code, ulations in compliance with RAS 127 tions shall be done as a moment based Product Description PA 112 One piece high profile clay roof tile egtuipped with two nail holes. For nail -on, mortar set and adhesive set applications. Accessory trim, clay roof pieces for use at hip;, ,rakes. riducs and valley terminations. Manufactured for each tilt profile. 2.1 COMPONENTS OR PRODUCTS MANUFACTURED BY OTHERS Test { { Product Product Dimensions Specifications � IDsrcr i pt i nn Tile Screws #8 x 2 -%'t long PA 114 . `litainless Steel 0.130" shank dia. Appendix E 0.173 flute dia. — Manufacturer generic 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance 3.2 For mortar or adhesive set tile applications, a s field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Mia perform quarterly test in accordance with PA submitted to the Building Code Compliance Of is i-Dadc County Certified Laboratory to 12 a .. hall be uloaga, RRC Roofing Product Control Examiner :V'i.t�in ^A.M•rn M✓tvyry •+4�'^aV.1Y,OFfoY AI'I'I; :t11)it t,l,•t, REQUIR.EI) oWNl.tzs NU'1'I1 tt.:,\i 1Ut\ 1 "011 Itl)(i INQ CONSIDERATIONS As 11 penal iii Iv this Appendix "p", it Ir 11t6 i ebltntttiLIllit)' of Iltc ruulltltt comitivtur {n luut•Itle the owner %vI;I, the rill lrtd MOnn hermll, to provide the owner tvltlt (1111 ennencliN alit to nx IC► IIN) N %%'IICr the co Or till{ fore!. The provIiivni Or Cl+nl►ter 311 ur the South I'lorltln f)ttilcling frolic (5r tic) govern ItIl the minimum rpguiremonts end standards or the Intl limy Inr rcxrfint; system hut lulinll ms nddiIiunull this rc►lio%i'Inii items should be addressed ns v tt or the ow re mcht Ueltvre„ suet usv■scr and the s•tnt1 motor '1 he et% II is 111111 l ill site ndjncont box Indicates Ihn1111c Item has Istr,t' e. phtlitcti. • 1. Aos,thetfcs•1Vurltt+tl+nsitip: '1I+e %%.tv•Lnt:+,lship l,tgvisil.+ns u( t. rovbi ng that the roofing system ascot the v.hus resistance unri wttt r Aesthetics (appearance) Issues me lint st cuttsitics r•uspeet too %'041 :..1, Such n! eoloror urt:1111ectttrAl nppt•ututlee, flint me'Io1 pet of a !omits; <It,cl ttgr tent the owner roil the rur+tlttt :tat 1 2. Remitting Wood I)ccata; ■\'lien talsinchtll ruuri'i . the eNIstItig ter ut r may have to be ranched accordance with thy careen! I)ruviti:nts ur Choptee 19 os'the S1 ('file 1'.u: ties!: is usually coil enlet) prior tit sot g the exlstln j roof systont) 3. Common Routs: C :untnt <1n rvt)1s me those 1cliit:11 have it victl,lt• tiellasentit►n between neightrotiutt units (i.e. townhouses, cancluntlnlu+n s, etc.). In t,uildings wit!) ennui's• tut rt. the rttt►fulp contcnetur a /ur pw� 3 ould notify the occupants ur acljut;e111 units ul Iuuril +14 wntk to he It tf<st 110. 4, Exposed cidlitigs; f'.ai,t? sett, u1Ien bttutt CeiIl,t, nrP % %'Itelc; 111.' ills: !trite ui' thn root sleeking call be. viewed rront below, The owner tnny %%'itit to nittintnitt tilt nrClUlcelu t1 n, ltenr :u tce, tht:l au, e 1001114 hail p.tttetratlone or tlle underside cif the tlect;inl; Inn t+ut to nc 'upinhte. ' ill! Ili : itavitles the tytllrslt u! tiy{ pp Mint!, x... 15. rounding \Vntev: 'site ct:rrcnt snot' s)stcul n: /ar sleek or Ili I.rtui1 I;ul: t1{uy nut clash %cell uI►tl may c11 SS water to pvhd (tt ctrntuintc) in Ivry -lying livens of tilt ►tsnl. I'uuJint; : be uu Indic :ctiou ur sttuctutal • i distress and may require the ICvics' c,r 11 Iiiotcsriunn1 stinctutitt rte atiees {'%mitt;} may shorten the ;life ' e3pecteltcy and perform ace of the ttcttw rocIfing system. I'ontlIttg cune{it1 ms tit.'%' not tu: e.vitlei+t until the oriiiival • II ;system . 1; removed, f'ouJii+t; c<3iid I tills should ht: conccled, '!:toter .11 ere for the purpose or M1111liu t Itclrl'nnttatiee stunJntds. tsttip I1c•uvisivns. aesthetic issues 1n,tu1t1 Ise nt,ht ns port or ttt �•�1 6, Overflow Scuppers (t►'tt11 uutlt:ls); it is ictlult'ctl the( t1+lr•+v:t •r flow ill' set that iho toor`If' net •;? r. uve oaded moot u build ti of %vntcr. l'cr hut 1ctiecige 4.vnlis or oilier roc c •r•nsiuns luny black lids dtsCllalgcJf: 'l? " overflow scuppers (wall outlets) me not pruvitkd. h may be neccasnr)' tt hi' oil five, llnw souppc;s its ncvortkince wit Chapter 23 ur the SFDC. .1/ 7, Yettltlntiots: Most toot shuc►u'es shoald have some Writ) tt' vent !+:thirsts nit 11ut% through Ott inlctip: a =trttcltlrnl assembly (Iht building itselr). '1 he existing, ;tnloutt; of 'tits" %cn►iltttion s clot bc.rtdutrd, I: . tI cfielnl to consider ndJi ti vual c,:nlin(t %t !tit + Cult result in e:;t, :t'<lin,• the Service lira: of ttte leaf. 8. Tho o\vnl:r ntuy conlnct t1t. N'tintltl•I);1tle County C om +ntt:1 ar.lvit:cs t)c for- I'{ttlhi' Inrorut - rdfl�b tit nlu,tc, 1I/ /�� nn lure whir cafe IS Uu {+ t "nt11r1tclur r 5401ttIure Its Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) 1 p ss 26 /I S S 51 2 27 52 3 28 53 4 29 54 5 30 55 6 31 56 7 32 57 8 33 58 9 34 59 10 35 60 11 36 61 12 37 62 13 38 63 14 39 64 15 40 65 16 41 66 17 42 67 18 43 68 19 44 69 20 45 70 21 46 71 22 47 72 23 48 73 24 49 74 25 50 V 75 Du Quesne & Associates, `� C• Consulting Engineers Testing Laboratory ORI -SOTS CObCE(YITRATED UPLO(FT LOAD TEST1(9C OF ROOF TOLE ORO ACCOL°3Dla(1CCE C?QVGI (METRO -DADE DQ>)1LDO(klG CODE COMPLOARICE PROTOCOL PA 906 SITE SPECIFIC INFORMATION UTIR. TO ll®5 Environmental o Civil o Structural Building Inspection Services Owner's Name: R 0 LAA/D J RA/.5 o/V Permit #' . o 77 Job Address 7 55 M E. ? 7 Or B(A JAM! Roofing Contractor A PA L(ER le 0 0 C/// ( ' i Type of Tile: S,4/"7 4 Pa , 5 Date Installed / Approximate Roof Height /8 feet Roof Pitch Type of Access to Roof: Scaffolds IV Ladder Other Approximate Square Footage of Roof 3800 ft Required Testing Force: 35 lbs. Testing Equipment: Chatillion DFIS 100 Date Tested / O TEST RESULTS P = PASS, F = FAIL SKETCH OF ROOF IN BACK IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. .....r... • e Du Quesne, P.E. Engineer P. 24513 Du •uesne & Assoc' . es, Inc. E.B. License #0005245 Lab Certification #94-0318.01 THIS PA 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTY, WITH NO DEVIATIONS. Please Note: This form is not valid unless Company logo appears in color (burgundy) 7815 S.W. 24th Street • Suite 109 • Miami, Florida 33155 • Telephone (305) 264 -1425 • Fax (305) 264 -1426 JOL1 SHEET NO OF CALCULATED BY CHECKED BY DATE SCALE DATE NOTES' $KETCH OF ROOF 71 5 5 N, E. 9 ? sr, /a-,4/ SHEET NO OF CALCULATED BY / & DATE ) /- Z -0 ( CHECKED BY DATE SCALE r JU drt l 5 EMONIIIIIMINEMINIMPft 2 PIMMINIERMIla fG11611111i111 1111111 \Ir�� 11 'es' • %■ EIMrMIL) / 2 1 1 NOTES' Name Address Company Phone # For Inspector: Approved Correction Re- Insp'n Fee MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request J, Time Type Insp'n Y O D F l c n a l Permit No. — ` I") Date