Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
74 NE 97 St (9)
MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build - ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date..._..F.ell _.. _ _..._.__ ...... 19..26 Owner's Name and Address... JogePh Nordone — No. ... ..t.Q Str eet N•W• 94 St. Miami Registered Architect and /or Engineer Name and address of licensed controctor Roofing, 7,57 N.W. Miami Ct. Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 74 N.E. 97th St. State work to be done and purpose of building (by floors )..._......RDDf ing R.e.s tdance... ......_..._ Install 1" insulation, 130 lb, ....felt, .f�..s. i> rig ,....�Ad...a.s�halt...shingles and for no other purpose. New Building Remodeling Addition Repairs X No. of Stories 1 To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ $2,1a9.,10 O Amount of Permit S. .. S...00 Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub•contrac ors employed by him pi in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of e 'k s�r`h public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcoj z ._tors, oq worht'o be/peflpfined under this pennit, as are licensed by Miami Shores Village. Remarks (Signed) ding Inspe or Date STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No. __._._I 3 Disapproved :._...._.. D (Signed) Read, Sworn to and Subscribed before me. Notary Public, State of Florida Commission Expires to me well known, LANNINC BOARD DATE Chairman Member Mernber Member Member ...... Member Council Approved. Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re-inspection Ice of $1.00 will be charged when such re- inspection is made neceuary by improper notice for inspection or faulty materials and/or workmanship. Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build - ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address Maiebo)v Registered Architect and /or Engineer. Name and address of licensed contrtctor... 4 !. 1V.1".IC, Zone cubage required therein by him s� te. Permit No.__...._ Date Disapproved _ Date. (Signed) MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT BUILDING INSPECTION DEPARTMENT built on: Building Inspector ` Chairman Mcrnbcr Member Council Approved Date _ Date..._ / /7i _. ,19..-- — No.7. P --6) . _. Str eet 7 CG617A4 ell�Z Subdivision. /in E.AL PL � .. �� PP 0 � S Sel7" r ? 1 . x'`1 ? . _ ..�I 1.. . - iz;gab �1< (,» (,» ref' $' A)CReTe e�GC7� ®f Co e2e7 Location and legal description of lot to Lot ° o Th. L6.f .. Block Street and Number where work is to be done. /U � j 7e t -Piee State work t o be done and purpose of b ilding (by floor) el-)E and for no other purpose. New Building Remodeling / Addition Repairs No. of Stories To be constructed of /Lfl 7- ]V' rtd of foundation.e ALL' `.'./1 C Roof Covering.. Estimated Total cost of improvements $ t 3 ®© Amount of Permit $. 1a , _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications said building. All notices with reference to the building and its construction may be sent to .1 / 97 sr j r�� ��J - S�G�.'S 2i 3 3) 3 Sl The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of Libor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors on work to a performed under this permit, as are licensed by Miami Shores Village. - Reinarks... (Signed) PLANNING BOARD _.._......DATE Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts Member Member Member ...._............_..�.._ Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning A re inspection fee of 31.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Date 2 1O Sff 41 Job Address Owner / Lessee / Tenant Owner's Address Qualifier V . 4 /dc% i WORK DESCRIPTION ( I_1 . 3(3 toSe Square Ft. / Sig s'ture of er Date: ** * * PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Legal Description Si. /1)0 97 �feFET Contracting Co. 1 / '` L RUOF /,..1 Notary as Xt Owner and /or Condo President My CoT9ssion Expires: J Lo geA/ v FEES: PERMIT 14 RADON C.C.F. APPROVED: Fire Zoning Buildin Mechanical Plumbin Tax Folio 2 Master Permit 11 Csn- Phone 7 41. " , g 2 Address .Z' So 26 Ai SS# — / Phone Y -VT - State # GLLo4 jy% Municipal # Competency # Ins.Co. Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING PENCE SIGN o -A 74 /e ys 4 A, ���/j1� Wtfq�7 C --2 1;20j. ir.cr /'JS ; /— 7 /c 7' ilk-1 ' /O/leer Ce I- Estimated Cost(value) /. 6 y. 4 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I rtify that all the foregoing information is accurate and that all work will be do in compl ce h all applicable laws regulating construction and zoning. Furthermore, I auth• ize the above -d contrackbr to do the work stated. ure o Date: a er- Builder Notary — to Contractor or Owner-Builder My Commission Expires: ? -j, ,. NOTARY TOTAL DUE 31 / 1 k 1 , ** Other p ectrical Engineering p.) NOTICE OF COMMENCEMENT PERMIT NO. TAX FOLIO NO. // J� 6 n7S - 0 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property. and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: 7 627 2. Description of improvement: /72 /'oo 7 41 tl? [2vi 2 7q- iq c 6 17 s- /14 t` ont. Sk s r(a 3 ' Interest in property: w "?-..e ow new Name and address of fee simple titleholder: 4 3. Owner(s) name and address: 4. Contractor's name and address: 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lender's name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes. Name and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expir tion date of this Notice of Co encement: (the expiration date is 1 year from the date of recording unless a differe t date is specified) �, L of Owner Print Owners Name Sworn to and subscribed before me this Notary Public - 2 Print Notary's Nam: Jo s G. Sort My Commission Expires: 3 - 2 STATE OF FLORIDA, COUNTY Or DADE r1E;'PEftP Ctit :tFY t a thi: is a 3 rue_ copy of the 0 t�'ln�� el i.t P .s o..i_e on 3 day of A 9 19 w TNF55 .ny h n,P ,�d Cff ;cioi H r RUV N CL r P1Lr • c it and Coynty Courts V 34- Jw 7 > 13 3 Prepared by: t;. Ifr,u /el Address: 3 +1' -Ito . 76 >d Job Address: 7 R 7 ST 1 f'ti yi s IIo e.crS APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II MORTAR OR ADHESIVE SET TILE SYSTEMS 1. General Contractor: The information provided in this Section is required to confirm Product Control Approval of the proposed tile system assembly; confirm compliance with the wind load requirements of Chapter 23 of the South Florida Building Code (SFBC); and confirm compliance with Sections 3403.5 and 3404 of the South Florida Building Code. 2. Documentation The following documents are required for submission with the Uniform Building Permit application: ► Two (2) copies of the proposed tile system assembly's and associated roofing component's Product Control Approval(s). ► One (1) copy of the tile system assembly and/or roofing component(s) manufacturer's published application instructions and literature. ► All documents attached herein, filled out and completed in full. 3. Project Information Check one of the following: ❑ New Construction Re -Roof systems are not acceptable as recover Note: Mortar or adhesive set tile applications. Mortar or Adhesive Set Tile Systems Page - 1 V aofenc Process No. o ey0 Is the deck solid sheathed? (circle 'yes' or 'no') ycs no Deck Type (check one of the following): ❑ Nominal '/" Plywood (for re -roof only) ❑ Nominal V Plywood f' Wood Plank /XL " ❑ Other (fill in) Roof Pitch (fill in): : 12" Note: Mortar or adhesive set tile systems shall not be installed at a pitch greater than 71/2":12 ". Mortar or adhesive set tile applied at a pitch greater than 5 ":12" and less than or equal to 7 ":12" shall have the first thrcc courses of tile nailed with not less than one nail per tile. As an alternate, the first three courses of tile may be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3 / 8 " which is mechanically attached to the sheathing with not less than one nail per 2 ft'. Circle 'yes' or 'no' for each of the following: Have you attached two copies of the tile system manufacturer's Product Control Approval for the proposed tile system? no Have you attached a copy of the tile system assembly and/or roofing component(s) manufacturer's published, application instructions and other literature no system assembly? Is the proposed underlayment approved for use with this tile yes no � Job Address: 2y ye 77 ,ST f .../iAtiti 5140e.a.S Project Information (continued): 4. The Tile System Assembly: Tile: Tile Name: Manufacturer: Tile Material: ❑ Clay ❑ Concrete ❑ Other: Product Control Approval Number:7g— 0 3 0 7 o q Mortar or Adhesive: yes no Cattail gr SNak ?• 1 on Q�� Contractor: If the proposed underlayment is self - adhered, have you complied with the venting requirements of Section 2913.3 (b), (c) and (d) of the South Florida Building Code? yes no N/A Are all related accessories approved for use with this tile system assembly? Are the proposed edge metal attachment fasteners in compliance with the requirements of the South Florida Building Code (minimum 12 ga. annular ring shank, corrossion reisistant nails)? yes no The following information is required to confirm compliance with Subsections 3403.5(a) and (c) and Section 3404 of the South Florida Building Code. Check one of the following which apply to the proposed tile securement for use with the proposed tile system assembly: Mortar or Adhesive Set Tile Systems Page - 2 ❑ Mortar: Manufacturer: Mixing Ratio: ❑ Adhesive: Type: Manufacturer: Process No. Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12" and is less than or equal to 7 ":12 "): Check one of the following which apply to the proposed tile fasteners (for the first three courses) for use with the proposed tile system assembly: ❑ Minimum 12 ga. galvanized roofing nail: f' N/A Length: ❑ Other: Type: Length: Note: All tiles shall be installed in compliance with the provisions set forth in the tile system assembly manufacturer's Product Control Approval and the minimum requirements set forth in Subsections 3403.5(c) and 3404.2 of the South Florida Building Code. Tile fasteners in the first three courses (if applicible) shall be of sufficient length to penetrate the sheathing a minimum of 1" or through the sheathing thickness a minimum of / ", whichever is less. Underlayment: The following information is required to confirm compliance with Section 3403.5(b) of the South Florida Building Code. or Job Address: 741 NE '7 1' P-{ 1A Li S 4 O S Undcrlayment (continued): Check all of the following which apply to the proposed underlayment for use with the proposed tile system assembly: Q ASTM #30 asphalt saturated felt with: Manufacturer: ❑ ASTM #15 asphalt saturated felt with: Manufacturer: Er Mineral Surfaced Roll Roofing with: Manufacturer: ❑ Other: Type: Manufacturer: A � 6 A r d/A Underlayment Fasteners (if applicable): O 19" overlap O 6" overlap ❑ 4" overlap ❑ 19" overlap O 6" overlap ❑ 4" overlap O 19" overlap Wi 6" overlap f ' 4" overlap Check one of the following which apply to the proposed underlayment attachment: O Minimum 12 ga. electro- galvanized roofing nail with minimum 32 ga. x 1' / tin cap: Length: 1 /ti Manufacturer: rJAc /e.94. oQ, EQ0a• ❑ Other: Type: Length: Manufacturer: Contractor: Process No. Spacing (per tile system assembly Product Control Approval): Field: � ' -' o.c. Laps: . " o.c. 5. Related Accessories: Mortar or Adhesive Set Tile Systems Page - 3 Edge Metal (refer to Section 3408.2 of the South Florida Building Code): Type: ■••■:L. p Dimensions: Gauge or Thickness: , (. t 9 Finish: ❑ Cold Adhesive: 9 , l Note: All edge metal shall be nailed on the flange and nailed or clipped at the face in compliance with the provisions set forth in Dade County Protocol PA 111, marked Appendix 'U' in the South Florida Building Code. Adhesives (check one of the following): Type: Manufacturer: ❑ Flashing Cement: Type: Manufacturer: 3';c3 Kl R Job Address: 7 NE q) 57 Contractor: Process No. d-- 1 1i .314o Adhesives (continued): Additional Notes: Note: Application of adhesives shall be in compliance with the Roofing Component Product Control Approval and the minimum requirements set forth in Subsection 3403.5(e)(4)(cc) of the South Florida Building Code. Ventilation System (check one or more of the following): The following information is required to confirm compliance with Subsection 3401.4(e) of the South Florida Building Code. ❑ Ridge: Type Size in Soffit: Types dcce■ Size 41( i& APPRDX Note: If underlayment is comprised of a self - adhered membrane, both soffit and ridge ventilation systems are required, unless a base sheet is applied as an anchor sheet below the self - adhered underlayment. Note: The Tile System Assembly shall be installed in strict compliance with the application instructions enumerated in the Product Control Approval. A permit shall be issued for application of the specified Tile System Assembly only. Any change to the specified Tile System Assembly shall require submission of a revised SECTION II with a copy of SECTION I, noting the permit number issued. Mortar or Adhesive Set Tile Systems Page - 4 Job Address: Contractor: Process No. Ridge Venting: N 1 Pt ( applicable ) Type: 1 Dcck: L Thickness.. 3 / Underlayment: 4 3 0 I' 409 0 Underlayment A Fastener: 1 • 1 ' FILLIN APPLICABLE ROOFING COMPONENTS WIIICII MAKE UP TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS INDICATING ADDITIONAL ROOFING COMPONENTS NOT SHOWN ON TIIIS PAGE. (Where Roofing Componcnt not used in Tile System Assembly, fill in with "N/A". ) Roof Pitch 12" Head Lap Dimcnsion: 3 (minimum 2' unless otherwise specified in the tile system assembly Product Control Approval Mortar/Adhesive: Tile: c_a44 J Tile Fastener: 14 ei2T Existing or Proposed Soffit Venting: Edge Metal or Gutter Fastener: :4 a 1 / Bird Stop: Of applicable ) Edge Metal___ or Gutter: DETAIL #1 Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 5 Job Address: 7 it 1 2 77 s Contractor: Process No. thMi SNoLe'S Ridge Height: Eave Height: Roof Mean Height al,_ D_ feet t JA.L. efeet ♦ I'). o fect AQ� Insert Building Ridge Height, Eave Height and Roof Mean Height. Also insert applicable information pertaining to the building below. ( See ASCE 7 -88 Fact Sheet Attached ) Exposure Category: Classification Category: At Hurricance Oceanline7: Y N Basic Wind Speed at Building Location 110 mph Building Condition based on % of openings: (See Table 9 ofASCE 7 -88) Ground Level BUILDING INFORMATION #1 Job Site Identification: Mortar or Adhesive Set Tile Systems Page - 6 Job Address: Contractor: v � Mortar or Adhesive Set Tile Systems Page - 7 Tbokn6 BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Job Site Identification: Process No. r Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment. Also insert variable labeled "a" which represents perimeter and comer dimensions per Chapter 23 of the South Florida Building Code. (See ASCE 7 -88 Fact Sheet Attached ) Job Address: The undersigned certifies that the Nail -on Tile System Assembly is in compliance with the plans, specifications, and details submitted by the architect. STATE OF FLORIDA - COUNTY OF DADE Before me this day personally appeared who, being first duly sworn, deposes and says that all information submitted herein is true and correct. sed Contractor / Owner Signature Sworn to and subscribed before me this Z th day of 69 197 My commission expires: `i3 f —Y r " Notary I . is State of Florida Contractor: Process No. / 7 Nair -Tile Systems Page - 8 Pioneer Concrete Tile 1340 SW 34th Avenue Deerfield Beach, FL 33442 YP- pRODUCT CONTROL NOTICE OF ACCEPTANCE METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Your application for Product Approval of Pioneer Concrete under Chapter 8 of Metropolitan Dade County Code governing the use of Alternate materials and Types of •`Construction, and completely described in the plans, • specifications and calculations as submitted by Conitruction Research Laboratory, Inc. and Professional Service Industries, Inc., has'been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the Specific Conditions set forth in pages 2 et seq. and in the Standard Conditions detailed on page 3. The Approval shall.be valid for a period of three years. The Office of Code Compliance reserves the right to require retesting of this system within the first two years-of the approval should any amen ts to the uth Florida Building code be enacted affecting this component or roof system. ACCEPTANCE No: 94- 0309.04 EXPIRES: M ^4 4 1997 APPROVED: MAR 1 4 1994 - **PLEASE NOTE ** • _ OOOQOI it Diamond, P;E. oduct Control Division Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. • This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code • Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger Building Code Compliance Department Metropolitan Dade County - THIS PRODUCT CONTROL APPROVAL SUPERSEDES PRODUCT _ CONTROL APPROVAL 90- 0711.028, #9.0- 0711.01, #9.0- 0711.03 & 92- 1114.01, #94- 0106.11 - Applicant; Pioneer Concrete Tile 1340 SW 34 Avenue Deerfield Beach, F133442 Category; ,Sub - Category; • Imo: sub -Type Product Control Notice of Acceptance Roofing System Approval Prepared Roofing Tile Nail- on/Mortar -Set Concrete System Description METROPOLITAN DADE COUNTY, FLORIDA _ METRO :DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 Product Control - 9 4 Approval Date: . Expiration Date: MAS 1 4 1 g 9 7 Pioneer Concrete Tile is a domestic manufacturer of extruded concrete roof tile with manufacturing plants stretching from theWest Coast to the Southeast. Products are fabricated from Portland Cement, placticizer,.iron and chrome oxides, and blended aggregates. Tiles are available in two profiles, and seven varietys for nail -on systems including 'Hacienda', 'Rustic Shake', 'Spanish S', 'Shake', 'Slate', Regal and '9" Flat. Tiles are also available in three varietys for mortar -set application. All profiles are available in a variety of colon, out of which are shown in sales brochures. Pioneer tile is fabricated with a wide ridged and grooved sidelap providing a water chnel at veritical joints. The ridged sidelaps provide a self aligning function, creating a uniformity in appearance: Matching trim pieces are manufactured for all profiles and form a part of -all Product Control Approvals. Pioneer markets a full tile system including all accessories required to construct a tile system. Pioneer Concrete Tile produces concrete tile for both nail -on and mortar -set applications. The minimum roof slope for all Pioneer Roof Tile slope is 2" : 12 ". Pioneer Concrete roof tiles have been tested in compliance with all South Florida Building Code requirements for nail -on concrete tile applications. Contact Dave Snyder, Gary Reed 1340 SW 34 Avenue -- Deerfield Beach, Fl 33442 (800) 624-4152 G11 THIS PRODUCT CONTROL APPROVAL SUPERSEDES PRODUCT CONTROL APPROVA 1190- 0711.02R, 1190- 0711.01, 1190- 0711.03, 1192- 1114.01, #94-0106.11 000002 • iamond, P.E. ; • NAIL -ON - MORTAR -SET Hacienda 2 Peice Barrel Shake Spanish 'S' Slate 9" Flat Rustic Shake • Spanish "S•" Regal J 9" Flat Maximum Design Velocity Pressure Material ]design Velocity Pressure Wood, Non - insulated psf (See Comments and Limitations) Material Wood, Nail -on System Trade Names . Maximum Fire Classification Classification Class A Q0-0003 Product Control No.: 94- 0309.04 • Product Dimensions . Shake or Slate Hacienda Rustic Shakes Spanish "S" Trade Names of Products Manufactured or • Labeled by Applicant 1T /a "x13" 17 x 13" 17 -112" x 13" PA 112 . Test Specifications Product Description PA 112 • Interlocing, high pressure, flat, extruded concrete the with a wide ridged and grooved sidelap; has two cast -in nail holes. PA 112 Interlocking, double roll, high pressure extruded concrete tile with two cast -in nail holes; has a wide ridged and grooved side lap. _ _00.000 17 -1R" x 13" PA 112 • Product Control No Interlocing, flat with scored surface, high pressure exulided concrete tile with a wide ridged and gooved sidelap; has two cast -in nail holes. • Interlocking, Mission S- shaped, high pressure extruded concrete tile with a wide ridged and gooved sidelap; has two cast -in nail holes. Valley Flashing Drip Edge Wood Battens Mopping Asphalt Flashing Cement Trade Names of Products Manufactured by. Others • Product - Dimensions Test Specifications #30 Felt ASTM D 226, Saturated organic felt to be generic type II used as a nailed anchor sheet. 4 Base Sheet ASTM D 2626 Saturated and coated generic organic base sheet for single ply underlayment. Mineral Surface Cap ASTM D 249 Mineral surfaced asphalt generic Sheet roll roofing. Asphalt Primer ASTM D 41 Cut back, asphalt based generic coating used.to facilitate adhesion of dissimilar materials. Min. 26 ga: x 16" ASTM A 525 Galvanized steel valley generic flashing. • Min. 26 ga., 2" x ASTM A 525 , Galvanized steel drip edge. generic 2 " . Min. 1" x 2" for horizontal, 1" x 4" for vertical ASTM D 312, Asphalt for bonding the generic type III or type mineral surface cap sheet IV to the base sheet. ASTM D 4586 " Cut bade, asphalt based, generic fiber - reinforced trowel grade cement for flashing and repair applications. LP -2 _ Roofing Nails Min. 1 ga. z 1" ASTM A 641 Corrosion resis . roofing generic nails. " • . - ,/� _ . - • ..0 - Product - Description Preessure treated wood • battens. - Gil Diamond, .E. r Product Control No.• Manufacturer generic • . Ti Ca ps • ,: Tile Nails Min. 32 ga.• z -• ; • • .• . 1 -5/8" - • Min. 11 ga. ASTM A 641 Corrosion resistant nails. generic Nail heads shall exceed the •size of nail holes in tile. Hurricane Clip PA 114 Galvanized , bronze, . aluminum, plastic, or stainless steel attachment clip for high windareas. Hurricane Clip R8 x 2" PA 114 Compatible fastener for generic Fasteners . clip Tile Adhesive ASTM D 3498 Structural bonding . Ohio Sealants, Inc. adhesive for roof tile. • Corrosion resistant circular generic discs. - . • -� •� V 6.6 6 - Gil Dia mond, P. • • • T generic Test Agency • Test Identifier Construction Research 45750 Laboratory, Inc. Infiltration Resistance . Test Reports • :5749 Wind Driven Rain • 02/25/93 Infiltration Resistance 4-5613 Wind Driven Rain 04/01/93 Infiltration Resistance 45613 Uplift Approvals, Static 04/02/93 Pressure Structural Uplift Resistance Professional Service 4395 -00074 Material Properties Test' 10/16/91 Industries, Inc. (Water Absorption and Breaking Strength) TestName/Report • Wind Driven Rain • Product Control No.: 1. Date 02/26/93 uJ /1b/a4 UV :14 . UIUb $Ib Z 08 Deck Type 1: Wood, non- insulated • Deck Description: New construction, I9/3r or greater plywood or wood plank. Slope Range: 2 ":12.-" to <4 ":1:Z" • - System A • Underlayment Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ", side laps shall be minimum 6 ". Fastening: Nails and tin caps„ two (2) rows staggered 12' grid. 6' o.c. at the laps. Membrane: Any approved mineral stufaad rolled roofing applied in hot asphalt or cold process cetnent(See Model Tile Specifications). Head laps shall be minimum 2', side laps shall be minimum 6". Vertical Battens: Vertical battens shall be installed on roof slopes of 2':12' to <4':12'. Min 1' x 4' pressure treated lumber. Battens shall be set in a max 1/8' thick continuous bed of compatible flashing cement and secured through the sheathing into the top cord of the truss with approved fasteners. . Horizontal• Battens: Horizontal batte:st shall be installed on roof slopes of 2':12' tb <4' :12'. • ' Horizontal battens shall be installed over the vertical battens. Battens shall be spaced to allow for a 3' minimum head lap, unless an approved headlap configuration which has been tested for water infiltration is used. Batten size shall be nominal 2' x 2" or 1" x 4'. All battens shall be pressure treated or decay resistant lumber and shall be installed in soda compliance with the manufacturer's application instructions and the Metro-Dade Model Nail -on Tile specification_ Roofing Tae: The tile system' shall be installed in compliance with the Metro Dade County Model Nail-on Tile Specification (Appead'ix'X of the South Florida Building Code), ionizing the components listed in the Products Listings' set forth is (his Product Control Approval. Applications, u detailed in the test reports, are consistent with the application methods stated in the execution section of said model specification. Maximum To be completed by May 30,1994. Refer to limitation No. 6. Aerodynamic Overtuning Moment Comments: 03-15 -1994 09 :20AM Systems For re -roof applications, 15/32' plywood is an acceptable substrate. 305 375 2908 woe COMYLIANC Product Control No 4 002 P. 02 • • Deck Type 1: Deck Description: Slope Range: _ System B. Underlayment: Fastening: Membrane: Vertical Battens: Horizontal Battens: Roofing Tile: Maximum Aerodynamic Overtuning Moment: Comments: - Wood, non - insulated • New construction, 19/32" or greater plywood or wood plank. 2 ":12" to <4 ":12" Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ", side laps shall be minimum 6 ". Nails and tin caps,. two (2) rows staggered 12" grid, 6 "o.c. at laps. Any self - adhered single -ply underlayment approved by the Chief Product Control Compliance Officer, installed in strict compliance with the Product Control Approval. Vertical battens shall be installed on roof slopes of 2 " :12" to <4 ":12 ". Min. 1" x 4" pressure treated lumber. Battens shall be set in a max. 1/8" thick continuous bed of compatible flashin& cement and secured through the sheathing into the top cord of the truss with approved fasteners. Horizontal battens shall be installed on roof slopes of 2 ":12" to <4 ":12 ". Horizontal battens shall be installed over the vertical battens. Battens shall be spaced to allow for a 3" minimum head lap, unless an approved headlap configuration which has been tested for water infiltration is used. Batten size shall be nominal 2" x 2" or 1" x 4 ". All battens shall be pressure treated or decay resistant lumber and shall be installed in strict compliance with the manufacturer's application instructions and the Metro-Dade Model Nail -on Tile specification. The tile system shall be installed in compliance with the Metro Dade County Model Nail -on Tile Specification (Appendix of the South Florida Building Code), utilizing the components listed in the Products Listings' set forth in this Product Control • Approval. Applications, as detailed in the test reports, are consistent with the application methods stated in the execution section of said model specification. To be completed by May 30, 1994. Refer to Limitation No. &. For re -roof applications, 15/32" plywood is an acceptable substrate: '000009 . Gil Diamond, P. . _ • • Detk Type 1A: Deck Description: Slope Range: System A. Underlayment: Fastening: 'Membrane: Vertical Battens: Horizontal Battens: Roofing Tile: Maximum Aerodynamic Overtuning Moment Comments: Deck Type 1A: Deck Description: Slope Range: • System B. Underlayment Fastening: Membrane: Vertical Battens: Horizontal Battens: • Roofing Tile: Maximum Aerodynamic Overtuning Moment: Comments: Wood, non - insulated • • 4 ":12" to 7 ":12" Wood, non - insulated . -. : V . NC 4/ construction, 19/32" or greater plywood or wood plank. • Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ", side laps shall be minimum 6 ". Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps. Any approved mineral surfaced rolled roofing applied in hot asphalt or cold process cement (See Model Tile Specifications). 'Head laps shall be minimum 2 ",.side laps shall be minimum 6 ". Vertical battens are optional for roof slopes of 4 ":12" to 7 ":12" Horizontal battens are optional for roof slopes of 4 " :12" to 7 ":12" The tile system shall be installed in compliance with the Metro Dade County Model Nail -on Tile Specification (Appendix 7C of the South Florida Building Code), utilizing the components listed in the Products Listings' set forth is this Product Control Approval. Applications, as detailed in the test reports, are consistent with the application methods stated in the execution section of said model specification. To be completed by May 30, 1994. Refer to Limitation No. 6. For re -roof applications, 15/32" plywood is an acceptable substrate. New construction, 19/32" or greater plywood or wood plank. 4 " :12" to 7 ":12" Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ", side laps shall be minimum 6 ". Nails and tin caps, two (2) rows staggered 12" grid, 6 "o.c. at laps. Any self - adhered single -ply underlayment approved by the Chief Product Control • Compliance Otficer, installed in strict compliance with the Product Control Approval. Vertical battens are optional for roof slopes of 4 ":12" to 7 " :12" Horizontal battens are optional for roof slopes Of 4 " :12" to 7 ":12" The tile system shall be installed in compliance with the Metro Dade County Model Nail -on Tile Specification (Appendix 'W' of the South Florida Building Code), utilizing _ the components lisfed in the Products Listings' set forth in this Product Control Approval. Applications, as detailed in the test reports, are consistent -with the application methods stated in the'execution section of said model specification. To be completed by May 30, 1994. Refer to Limitation No. 6. For re -roof applications, 15/32" plywood is an acceptable substrate. • _ Deck - Type 1B: Deck Description: - Slope Range: • System A. Underlayment: Fastening: Membrane: Vertical Battens: • Horizontal Battens: Roofing Tile: Maximum Aerodynamic Overtuning Moment: . Comments: - • • Wood, non - insulated • New construction, 19/32' or grater plywood or wood >7 ":12" Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimu r, side laps shall be minimum 6 ". Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps. Any approved mineral surfaced rolled roofing applied in hot asphalt or cold process cement (See Model Tile Specifications). Head laps shall be minimum 2 ", side laps shall be minimum 6 ". • Vertical battens arc optional for roof slopes >7 ":12 ". Horizontal battens shall be installed on roof slopes >7 ":12 ". Horizontal battens shall be minimum 1" x r treated lumber shall be installed directly to the deck in a maximum 1/8" thick bed of flashing cement and segued through the sheathing into the top truss cord with approved fasteners at a maximum rate of 24" o.c.. Spacing shall be in compliance with the Metro-Dade County Model Nail -on Tile + Specifications and the manufacturer's recommendations. The Metro-Dade Specification shall take precedence. The tile system shall be installed in compliance with the Metro Dade County Model - Nail -on Tile Specification (Appendix 'X' of the South Florida Building Code), utiliim g the components listed in the Products Listings' set forth in this Product Control Approval. Applications, as detailed in the test reports, are consistent with the application iuctnods stated in the execution section of said model specification. To be completed by May 30, 1994. Refer to Limitation For re -roof applications, 15/32" plywood is an acceptable substrate: • Gil Diamond, P.E. G00011 • _.DccTYPc 1B: • .. Deck Description: Slope Ran ggc: . • System B. • Underlay Vertical Battens: Horizontal Battens: Roofing Tile: Fastening: Membrane: MaXitnum Aerodynamic Overturning Moment: Comments: • Wood,' non - insulated New construction, 19/32" or greater plywood or wood plank. >7 ":12" Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ", • side Iaps shall be minimum 6 ". , • - • Nails and tin caps, two (2) rows staggered 12" grid, 6 "o.c. at laps. • • Any self - adhered single -ply underlayrnent approved by the Chief Product Control Compliance Officer, installed in strict compliance with the Product Control Approval. Vertical battens are optional for roof slopes >7 " :12 ". Horizontal battens shall be installed on roof slopes >7 1 :12'. Horizontal battens shall be minimum 1" x 2" treated lumber shall be installed directly to the deck in a maximum 1/3" thick bed of flashing cement and secured through the sheathing into the top truss cord with approved fasteners at a maximum rate of 24" o.c.. Spacing shall be in compliance with the Metro -Dade County Model Nail -on Tile Specifications and the manufacturer's recornmendations. The Metro -Dade Spaification shall take precedence. Tne tile system shall be installed in compliance with the Metro Dade County Model Nail -on Tile Specification (Appendix 'W' of the South Florida Building Code), utilizing the components Iisted in the 'Products Listings' set forth in this Product Control ApprovaL Applications, as detailed in the tat reports, are consistent with the application methods statcd in the execution section of said model specification. To be completed by May 30, 1994. Refer to Limitation No. 6. For re -roof applications, 15/32" plywood is an acceptable substrate. • • 0.0012 . toeck Type 2: Wood, non insulated, mortar set Deck Description: New construction, 19/32" or greater plywood plank Slope Range: 2 ":12 to 7 ": 12 System A. - Underlayment: Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ",side laps shall be minimum 6" Fastening: Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps. . Membrane: Any approved mineral surfaced rolled roofing appliied in hot ashpalt or cold process cement (see Model Tile Specifications): Head lap shall be minimum 2" and side lap shall be minimum 6 ". Vertical Battens: None Horizontal Battens: None Mortar /Adhesive Approved mortar shall be used All tile shall be set in a mortar patty as set forth in the Model Mortar -Set Tile Specifications. Mortar shall be Type "M" mixed in ratio set forth in the 'Products by Others'. Any adhesive application shall be applied as set forth in the adhesive Product Control Approval. All tile and accessories shall be installed in compliance with /system #3 of the Dade County Model Tile Specification. Roofing Tile: Maximum Design Velocity Pressure: Comments: Install one of the following profiles: Concrete Barrel, Spanish "S ", or 9" Flat Concrete. The tile system shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Appendix T of the South Florida Building Code), utilizing the components listed in the Products Listings' set forth in this Product Control Approval. Applications, as detailed in the test reports, are consistent with the application methods stated in the execution section of said model specification. See Limitation No. 6. For re -roof applications, 15/32" plywood is an acceptable substrate. On slopes 5 ":12" to 6 ":12 ", the first three courses of tile shall be nailed with not less than one nail per tile. As an altemate, the first three courses shall be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3/8" which is mechanically attached to the deck with not less than one roofing nail per every 2 ft For pitches from 6 ":12 to 7 ":12, every third tile of every fifth course, beginning with the eight course, shall be nailed. On slopes>7 ":12" all provisions of 'System 1' of the Dade County Model Horizontal Batten Nail -on Tile Specifications shall apply. 000013 Product Control No.: 94- 0309.04 t Roofing Tile: Maximum Design Velocity Pressure: Comments: Product Control No.: 94 -0309.04 Deck Type 2: Wood, non insulated, mortar set Deck Description: New construction, 19/32 " or greater plywood plank Slope Range: 2 ";12 to.7 ": 12 • System B. Underlayment: Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2" side laps shall be minimum 6 ". Fastening: Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps. Membrane: Any mineral surfaced, self - adhered single -ply underlayment approved by the Chief Product Control Compliance Officer, installed in strict compliance with the Product Control Approval. Vertical Battens: None Horizontal Battens: None Mortar /Adhesive Approved mortar shall be used. All tile shall be set in a mortar patty as set forth in the Model Mortar -Set Tile Specifications. Mortar shall be Type"M" mixed in ratio set forth in the 'Products by Others'. Any adhesive application 'shall be applied as set forth in the adhesive Product Control Approval: All tile and accessories shall be installed in compliance with /system #3 of the Dade County Model Tile Specification. Install one of the following profiles: Concrete Barrel, Spanish "S ", or 9" Flat Concrete. The tile system shall be installed in compliance with the Metro Dade County Model Mortar /Adhesive -set Tile Specification (Appendix 'X' of the South Florida Building Code), utilizing the components listed in the Products Listings' set forth in this Product Control Approval. Applications, as detailed in the test reports, are consistent with the application methods stated in the execution section of said model specification. See Limitation No. 6. For re -roof applications, 15/32" plywood is an acceptable substrate. On slopes 5 ":12" to 6 ":12 ", the first three courses of tile shall be nailed with not less than one nail per tile. As an alternate, the first three courses shall be applied in mortar over a single layer of minimum 12 ga. wire mesh with square openings of not less than 3/8" which is mechanically attached to the deck with not less than one roofing nail per every 2 ff. For pitches from 6 ":12 to 7 ":12, every third tile of every eh course, beginning with the eight course, shall be nailed. On slopes>7 ":12" all provisions of'System 1' of the Dade County Model Horizontal Batten Nail -on Tile Specifications shall apply. Limitations: 1. This system assembly maybe applied to roof slopes of 2 ":12 " and greater. • 2. Vertical and horizontal battens shall be used on all tile applications on slopes of 2 ":12" to 4 ":12 ". 3. Horizontal battens shall be used on all tile applications on slopes of >7 ":12 ". 4. Nails for attachment of tile shall have heads larger than the pre - formed nail holes in the tile. 5. All nails shall be corrosion resistant. Exposed nails shall be hot dipped galvanized, stainless steel, or copper only. 6. Allowable height above ground shall not exceed a maximum height of 45' for non - coastal, 30' in Coastal Area 1 and 2, and only by job approval from the Chief Product Control Compliance Officer in Coasal Area 3. 7. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida Building Code. 8. All tiles shall bear the imprint of the manufacturer's name or logo, as noted attached, to permit identification in the field. 9. The manufacturer shall retain the services of an independent testing laboratory to maintain quality control. Testing shall be performed on a minimum of five (5) tiles every three (3) months, for strength according to Section 3404 of the South Florida Building Code, and for moisture absorption according to PA 112. Test samples shall be selected by a laboratory according to ASTM D 3665. Results shall be forwarded to Dade County Product Control Section. Test reports shall bear a description of the tile by material and color, i.e. cement, grey. 10. All domestic distributors of foreign manufactured tile shall have a completed distribution agreement filed with the Metro Dade County Office of Code Compliance confirming the distributor's agreement to adhere to the conditions of this report. 11. Pioneer Concrete Tile shall be installed in strict compliance with the application instructions noted herein as well as the manufacturer's and Metro -Dade County specifications and application instructions. The Metro Dade County Model Tile Specification shall take precedence. 12. The Use of all pre-formed and specialty tile tested is required as it forms an intricate part of these Product Control Approval tests. 13. Applications for roofing permits must be accompanied by Section II of the Uniform Building Permit, clearly indicating the extEnt of the -work to be performed, along with current manufacturer's specifications and details. In . addition, a copy of this approval shall be attached to the permit application. Reference shall be made to all appropriate data for the required fire rating. - =000015 Approved: Expires: 14. The following documents were submitted with the application: Product literature on the following profiles: Hacienda Rustic Shake Spanish 'S' Shake Slate 9" Flat • 2 Peice Barrel Spanish *s. Product profile drawings -- Application Instructions Acceptance Number: il Diamond P.E. Metropolitan Dade County Office of Code Compliance 4 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Extension of Acceptance may be considered alter a new application has been filed and the supporting data, test reports no older than ten (10) years, have been re- evaluated. All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of Florida. 2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination, unless prior approval is granted for revisions or change. 3. Any unsatisfactoiy performance of this product or process or a change in Code provisions shall be grounds for re-evaluation. 4. This acceptance shall not be used as an endorsement of any product for sales or advertising puiposes. • 5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 6. Product approval drawings, where required for. permit applications, shall be provided to the applicant b PP gs. 4 Pe PP � P PP - by the manufacturer or his distributors; unless otherwise noted in the Notice of Acceptance. The prints need -not be re- scaled by an engineer- - 7. An annual certificate confirming listing with Factory Mutual Research and Underwriters Laboratories or such other listing agency approved by the Office of Code Compliance shall be submitted on or around the first of April annually- 3. Failure to comply with Standard Conditions shall be cause for termination of Approval. 00 Mb I t U -UAL)b I:LAC•iLEH BUILUINCG • BUILDING CODE COMPLIANCE DEPARTMENT • .SUITE 1603 •METRO.OADE FIAGLER BUILDING • • 140 WEST FLAGLER STREET • . MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 • • FAX (305) 375 -2906 Diamond, E✓. roduct Control Division Supervisor • • • 'FIELD TILES Hacienda _ TRIM TILES Hacienda e - G00018 • UNIVERSAL RAKE Hacienda, Shake, Slate Trim Shake or Slate • " HIP & RIDGE • . i • 1, u 9 _ .SPANISH "S" • 000019• • • Technical. Data 2 -1 /2" T ,..: Y).. 53 / 4 " _COOO2O _ SPANISH 'S" CUT Techniea Data • • • • • • 'echni`caf_ Data . - - • BARREL. • • 1/2" TYP • Technjca:1 Data VS" Rustic-Shake•n.d 5 Tile - 000022: 1 • I+- 3.5 "--'I Technical Data _ Rake Trim - = - •Rustic Shake and Slate?iie GQr�1:�3- .•