Loading...
601 NE 96 St (2)MIAMI SHORES VILLAGE, FLA. N9 6352 JOB ADDRESS INSPECTION TIME READY REMARKS • INSPECTOR DATE MIAMI SHORES VILLAGE, FLA. N? 6381 JOB T C1 ADDRESS 7 c r 5 (*r r — INSPECTION T l0 1 w TIME READY 1 I �� —" (7. -1 REMARKS • INSPECTOR DATE PERMIT APPL CATION FOR MIAMI SHORES VILLAGE fJ /9 Pit- Date 0 50 0 /(/ Job Address X 60/ DE 96 Sr; Tax Folio Legal Description owner/Lessee/ T �PIP��� efie Contracting CoX J ®wiv i9 Mortgagor ature of owner and/or ondo President AU Notary as to Owner and/or Condo President My Commission Expires: FEES: PERMIT - i RADON APPROVED: Zoning Mechanical B Plumbing at Address OFFICIAL NOTARY SEAL SANDRA A BUSTA NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC775257 MY CO MISSION EXP. SEPT 14,2002 Historically Designated: Yes No Electrical Master Permit # Owner's Address 692 // /7' 9,4 c , Phone 3 03 — 1.-/ 9' 9 Address ,59e /✓5O /sr. Sr N/0/ /Cx •35/.3g Qualifier TO/VA/ R Sz�i2T �� SS# Phone , s /9• Q 7 9 State # CCG Qggb ®W{ ' Municipal # Competency # Ins. Co. Architect/Engineer NA Address Bonding Company ,/ /, Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING AVING FENCE SIGN WORK DESCRIPTIONX eeP'A' — " D/�cX_ ARz ' 6 '3 %/ si FPtE Square Ft. 25 F7-". (L4fJS7//s24/ s` y Oft4 Estimated Cost (value) �'` � - c 9 - WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize)* above -named contractor to do the work stated. Signature of ontractor or Owner- Builder 1.4.(o,-01 So(it. C . 4I1Jit LOO - d Date Date Notary as to Contractor or Owner- Builder My Conunission Expires: OFFICIAL NOTARY SEAL SANDRA A BUSTA NOTARY PUBLIC STATE OF FLORIDA COMMISSION NO. CC775257 MY COMMISSION EXP. SEPT 14.2002 ' NOTARY 0 -- BOND o ' /& d Date Structural Engineer Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Contractor's Name:\J 4 (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) Job Address: ROOF CATEGORY ❑ (Nail -On Tile) ❑ ( Metal Roofs \Wood Shingles & Shakes) ROOF TYPE ❑ New Roof ❑ Re- roofing ❑ Recovering ilRepair ❑ Maintenance ❑ (Mortar- Adhesive Set Tile) ❑ (Other) Flat Roof Area (ft') RS Sloped Roof Area (ft') —�^ Total (fi � Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7 -88 table 1): / ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) ARE 1 1. GAS E % f - ` -.• TYPE—NATURAL ' ; X ❑ Ft. A V Ft. V ATTACHMENT SPACING Deck type: / /V/da Fastener Type: Field: Perimeter: Corner: DETAIL 1 & 2 ROOF PLAN 123.01-78 4/99 Page -1 e Venlilationh MEAN HEIGHT Deck type: zUnderlayment: Insulation: Appendix "E UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 12" ROOF SLOP[ D E T A I L 3 (Pmaxl: X X (Aerodynamic Multiplier): ) - M (Pm ax?: x X (Aerodynamic Multiplier): ) - M (Pmax3: X X (Aerod Multiplier): ) - M SLOPED SYSTEM DESCRIPTION Fastener type & spacing: Cap Sheet: Roof Covering: TILE CALCULATIONS = M = M = M Page -2 Drip edge: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Miami -Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals PCA: PCA: PCA: APPENDIX "F" REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to this Appendix "F', it is the responsibility of the roofing contractor to provide the owner with the required roofing permit. to provide the owner with this appendix and to explain to the owner the content of this form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum requirements and standards of the indus- try for roofing system installations. Additionally, the following items should be addressed as part of the agreement between thee owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the u ose of rovidine that P rP P _ t the roof- ing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 29 of the SFBC. (The roof deck is usually concealed prior to removing the existing roof system.) (&3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. town- houses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupat,ts of adjacent units of roofing work to be performed. PO u1.4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the under- side of the decking may not be acceptable. The SFBC provides the option of maintaining this appearance. 14 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to P and (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roof- ing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 44 6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with Chapter 23 of the SFBC. (14 Q7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structur- al assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider venting which can result in extending the service life for the roof. C k-S. The owner may contact the Miami -Dade County Consumer Services Department for further information regarding the above. wner's /Agent's Signature 127.01 12 PACE 2 7/99 . Date Contractor's Signature BUILDING ELECTRICAL PLUMBING ROOFING Owner of Architect Contractor or Builder Legal Description El Building a Lot CONTRACTOR OR BUILDER MIAMI SHORES VILLAGE, FLORIDA PERMIT B1 N9 6016 Signed. ..rtJ In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in complian pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper au cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. DATE ti Contractor's License No 19 6 ❑ Work to be performed under this Permit Subdi- vision Address of Value of - ( Amount of Building — Project $ `� " Permit $ f This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. INSPECTOR with all ordinances aft regulations orities of Miami Shores Village. In ao BY AUTHORITY •aeon PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date / / Job Address �/ Y b 7� • Tax Folio Legal Description O wner/Lessee / Tenant // / i �i /lL`"� !i /� !Ti' /i / ' . ster Permit # Owner's Address Contracting Co. i1 /' / /J�1L� �:' Address llalifier Gr✓ E'1 r� SS# Phone Ins. Co. State # ... Competency # Address Address Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING AVING FENCE SIGN WORK DESCRIPTION c"6 / ^/f /4- Lv4) 1//;( ,,,f4 ape 56- W, 7a,:s- Square Ft. Est mi ated Cost (value) if 36.0' O L.--- WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that . the fore:oing information is accurate and that all work will be done in compliance with all applicable laws regulating correction and zoning. F au ,,: above -n ed contractor to do the work stated. //(1/ ture of owner and/or ondo Presid Date Di, SI) 93 Notary a o Owner My Commission Exp FEES: PERMIT eg- 3 o -p ' T BECKE CC786697 4, 4`9r C0.'ALJSSlOtd EMPIRES COMMSS'.OH NUMBER OF FAO NOV. 1 5,2002 RADON C.C.F. ti O NOTARY S. 0 () BOND hone i,30.0 7-5 `f / / X 43i7 Signature of Contractor or Owner- Builder Date Notary as to Contractor or Owner- Builder My Commission Expires: Electrical Structural Engineer Date PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 3/ 4 /7f Job Address 601 N.E. 96 St. Legal Description M.S. Owner / Lessee / Tenant '2'✓/1{/€7'n 9I1,cQ � $S T e , e 3: n eLiCi Master Permit Owner's Address 60/ I n Contracting Co. Q iOilIrk a , Address Qualifier SOL (. (' l (- . State # °k61°8/1 Munic' pal # (p� Competency # Ins.Co. IN 6 Architect /Engineer Address Bonding Company Address Mortgagor Address Permit Type(circle one : BUILDING ELECTRICAL $LUMBING MEC• ICAL ROOFING PAVING FENCE SIGN WOR DESCRIPTION ie- r / ''- I I L(p n 1 n Square Ft. ' /V Estimated Cost(value) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zonin:. Furthermore, I authorize the above -name , contractor to do the work sta •-•. 1/ / r �, � d -P , I ,iJ / f owner and /or C•` do President gnature of Contractor ; Date: Si D 1 qs c Notary as to Owner and /ok : d :'• 'rani .e t My Commission Expires: �_Notary; EL PAMA ■S CIDDY ::: Public -Stato of Florida My Co mm. Exp: 08118/98 i, k // ,0\� Commd: CC383787 ** * * * * FEES: PERMIT ;5° RADON APPROVED: Zoning Sec 4 AMD PB Lots 11 thru 18 Blk LOT SIZE 435.030x1 Mechanical C.C.F. Nd Building Tax Folio 11 3206 017 1700 Nota My C msssf.4 9x' T � ` ; * r � � F Le Phone Phone 969/ if 61.47 0 .1 Owner- Builder r- Builder ��. v ccyn f R e �®� A IL ANA M BAR NIEL COMMISSION NUMBER CC314598 M* coMMI*SION E. SEPT 121997 NOTARY TOTAL DUE 12e/ 2/ a a� * ** Fire Other Electrical Plumbing Engineering _., ,.,.n .� TAX FOLIO # 1 1-3206-017-1700 'PATE; ;`OF ' FLORIDA : L'1D .. :,;..'. 95R cs3o92 1995 MAR 16 10 :22 THE hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713. Florida Statutes, the following information is provided in this Notice 1—Legal. description of property and street address: Miami Shnrpt' Spr 4 AMU] pR lots 11 thru 18 .•_BLK LOT SIZE 435.030x1 601 N.E.. 96 St. Miami F1 33138 2. . 1 s ption o ovement: is „ , * Al iii i - U ilh i'h' &Jiu' r 3. er(s I name arA address: i '/t Q/ Pept541-pojitisi n /obi ?,) , 96 As qua MPC 3 4. 3 . S Interest in property ° K V1? p, q game and address of fee simple titl - holder• I. Contractor's name and address: 5. Surety: (payment bond 1e red by owner from contractor, if any) Blame and'address: IA IT11 , ,mount of bond $ Lender's name and address: '. Persons within the State of Florida designated by Owner upon whom notices or other documents may >e served as provided by Section 713.13(1)(a)7.,Florida Statutes. tame and address: t. In addition to himself. Owner designates the following person(s) to receive a copy of the .ienor's Notice as• provided in Section 713 .13(1)(b),Florida Statutes. tame and address: ▪ Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of ecording unless a different date is specified) NOTICE OF COMMENCEMENT • NIR tur of Owner l DPI rn to and . subscribed i - fore me `t'ttis 0.7 day of ( . 19 s5 otary Public @ Qc, '-'9,J,)();)kk y Commission Expires: • i ;•N !. PAMELA S RODD otary _Sts to of Floods < pub 1i C,s My Comm. Exp: 08/1 / //1 Nse Commit: CC383787 I ITATE OF FLORIDA, COUNTY OF DADE • 1 Ms' Mot this Is o true cop of the. Cr) r • 08 f'. d in fhb off co on d ®y o A•O.,19 MINE my h nd and Officio / Soaf. F1ARR Y RUV(N, GLERK, of circuit a f County Courts oy ▪ f y C. . Prepared by: :•TAIL THIS DOCUMENT. TO: DADE COUNTY RECORDER 44 .West Flagler ST 8th FL MIAMI, FL 33130 phone # (305)372 -7777 �//3 % ,5"4 oa 6 GAFGLAS® Specifications 1 - 0 - 4 - /P6, Slope per loot Up to 3" 3'- 6' UL Class A B Substrate Slope C C Asphalt Type Steep ASTM Type I I I HT -Steep ASTM Type IV 2" 3 ' /2" Insulation 3A 3A Specifications General Application recommendations detailed on pages 17 -20 shall apply in addition to the following recommendations and specifications. Application of Roofing Membrane Starting at the low point of the roof, mop three plies of GAFGLAS Ply shingle fashion; lapping each sheet 24 3 14 inches over the preceding sheet; solidly mop- ping to the underlying substrate to provide three plies over the entire roof area. Asphalt Requirements Interply moppings of Roofing Asphalt must be applied in a continuous film and shall consist of approximately 25 pounds per 100 square feet of roof area with a tolerance not to exceed 20% plus or minus. The appropriate asphalt for the slopes involved must be used. On slopes up to 1 /2 inch per foot, Flat ASTM Type I I may be used except in Florida, Texas, New Mexico, Arizona, and California. Surfacing Apply GAFGLAS Mineral Surfaced Cap Sheet in accordance with application instructions on page 20, so that the laps are offset from the laps of the ply sheets. Special Instructions 1. For roof slopes of 1 inch per foot or more, all plies must be back - nailed 4 inches in from the back edge of the felt into wood nailers. See "Installation on Steep Roofs," page 10. 2. For insulated decks, there are some restrictions. See "Roof Insulation," pages 10-11. UL Classification UL Chart Key 1. Substrate C = Combustible and Noncombustible Combustible = Wood planks, boards, etc., plywood (min. "/32 inch thickness), oriented strand board (min. /2 inch thickness). NC = Noncombustible only Noncombustible = Steel, poured or precast structural concrete, lightweight Insulating concrete, gypsum, structural wood fiberboard, etc. 2. Slope Maximum slope allowed, In inches per foot. 3. Insulation 3A = Optional, GAFTEMP® Perlite, Isotherm R and composite Insulations. Guarantees Available Specficetion Liberty Guarantees I' O -4-WP6 20,15, 2 +10,10 yr. l.04=M and NN -0-441 2 +10,10, 5 +5, 5 yr. akafil 3t31 N irri artaiivi 33"50 I- 0 -4 -M, and NN Non- Nallable Deck or Acceptable Roof Insulation R Asphalt R Side Lap oofing GAFGLAS Ply North, South & West Zones GAFGLAS Mineral Surfaced Cap Sheet CO. CORPOOUMON Non- nailable decks or insulated decks up to 6 inches per foot slope. Poured concrete, precast concrete, acceptable roof insulation. See "Roof Insulation," pages 1.0, 11, for recommendations for roofing over GAFTEMP® Isotherm R Insulation. Materials GAF Materials Corporation Asphalt/Concrete Primer (when applicable) GAFGLAS Ply (3 plies) GAF Materials Corporation Roofing Asphalt Interplies Cap Sheet GAFGLAS Mineral Surfaced Cap Sheet (1 ply) Approximate Weight per Square 210 -230 lbs. sP 25 4-11/ ,$' Ame s r ) r:Sb f ¢ 2ti1/j/`� C:,QlI / Base Sheet: Fasteners: APPENDIX °E' Job Address: (off nf % °1' Contractor Process No. METRO -DADE UNIFORM BUILDING PERMIT SECTION II BUILT -UP APPLICATIONS AND MODIFIED BITUMEN SYSTEMS GENERAL: Type of Roof System Assembly to be Applied: 1770•/,7",E 1 , S' Manufacturer of Roof System Assembly: (r 4' 1. Product Control Approval Number: :id/ y, System Number from Product Control Approval: / - 6— 1 94 (Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System Guide Specification. ) ( Note: If a minimum roof system is to be applied, describe all components within the system and list the manufacturer of each component. DO NOT complete this section if system is Product Control Approved. ) Ply Sheet(s): Cap Sheet: Asphalt: ( Note: No insulation system is acceptable under the minimum roof category. ) Complete the following for all Roof System Assemblies: Built -Up Applications and Modified Bitumen Systems • Page -1 Job Address: C "/91•F 9t; (Check one of the following) Recover Re -roof: If a recover, is the existing Roof System Assembly to be used as a bonding substrate ?: Y ✓ N If YES, has an ASTM E907 test been carried out to confirm adhesion of the existing membrane to the substrate ?: (If 'yes , attach ASTM E907 test report. ) Proposed Fastener: (Attach withdrawal resistance test report. ). Has the deck been examined for moisture ?: (Provide data confirming compliance with Section 3401.9(c) . ) THE SYSTEM: All Roof System Assemblies in the Product Approval have a variety of options. Briefly describe the Roofing Components to be used in the Roof System Assembly and attach a copy of the manufacturer's published specification: Deck: (Briefly describe ) Insulation: (Type, size and method of attachment, if applicable ) Base Sheet or Ply: ( Type and method of attachment ) 3oi sTR4114%. Contractoguaa F " 5© Process No. New Construction Y 6 y Ply Sheet(s): 5 fly 0g (47as ( Type and method of attachment) / L p /1/ Y ]Built -Up Applications and Modified Bitumen Systems Page -2 N 301 KW. TtSBE f IVITAM� FL. 33'130 Job Address: eel ij L 76 9' Contractor Process No. Lea Top Ply: (Type and method of attachment ) /41- n of w •'1/ T /11 Is "4 4// 1- s„,, r 54..7 ,/ w 111 /h 74 Tan 7f,4- i// asii.. /P Surfacing: 9/114% e S: Att. c e -� (Type, if applicable ) Flashing Materials: (Type and method oj attachment ) /— "Melt 4e 1 13 0 gi-e- /Io J in /9 7» A 5'11 /f re-"- l. r.7►ii Q a ig ti o A - 814 6"". C 4 444 e• 4: Built -Up Applications and Modified Bitumen Systems Page -3 Job Address: CoiZE, 9L 30I N.w. 7t sT ' MIAMI, Ft.. 33430 Contractor inches tI� I _ inches A — inches FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND INSULATION LAYER(S). (Where Roofing Component not used in Roof System Assembly, fill in with "N/A".) Top Ply: CA�v / S',{ >4 e Bonding Material: A/ / ASPi /t Ply Sheet(s): 3 -/°� 6T • *net Bonding Material: /dSp4 I/ pi.' ez Surfacing: `7tn- ee v/sgtnr i c t i ( briefly describe, tf piieable) Fastener. /Y /A (1/ base sheet mech. attached) Base Sheet: MJ'F Bonding Material: As Whose sheet bonded) Fastener. (ijtop intu/anon layer mech. attached) Top Insulation Layer: / I pe^ 41 a- ( applicable ) Bonding Material: RI top inndanen layer bonded) Fastener. (Ijintulation mech attached) Insulation: � Vapor Retarder: (ifopplieable) Primer: (ijappiicable) uil1 i gse1a Bonding Material: n..... •.;sQ.c;43�'. ?fi'S: ?; ::;:;:'•::.'•::•:.^�� (ijinrulation bonded) Density, ijconcrete deck: DECK: f Type: G e t C ,I .d e Gage or Thickness: !L A 4 a /< r�J. Built -Up Applications and Modified Bitumen Systems Page -4 Process No. 301 N.W. Yt S Job Address: ta /ZE. 9d ` Contractor '"'Process No. PERIMETER DETAIL. #1: Parapet Wall Detail : Coping Cap Clap Fastener Spacing _ o.c. Clip 'Iype: clip case: /// Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Parapet Walls. Insert leaders indicating Roofing Component names, dimensions, thida briers, eta Include fastener type and spacing used for wood - blocking attachment. Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Areas to be Flashed. Insert Leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment PERIMETER DETAIL #2: Flashing Detail Built -Up Applications and Modified Bitumen Systems Page -5 fob Address: Coo y1.E. cG s,; Sketch Roofing Component which make up Roof System Assembly at Perimeter Edge with Gravel Stop or Drip Edge. Insert trades indicating Roofing Components names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment Gravel Stop/Drip Edge Gage: Fastener Spacing. o.c. Clip Type: Clip Gage: Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gutters. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment Gutter Type: Gutter Gage: Fastener Spacing: C.AX.RU 1 li R001. 40{1F $, FLAX. 3 01 N.W. MIANG Contractor ' Ft. 3.3150 Process No. PERIMETER DETAIL 43: Gravel Stop or Drip Edge PERIMETER DETAIL 44: Gutter Detail Built -Up Applications and Modified Bitumen Systems Page -6 \J\f Deck Type: Job Address: CofZt. 96 Contractor 30 . i1 ;. F,`'..tL'l MIAMI, F1.. 31 PERIMETER DETAIL #5: 'Other' Detail PERIMETER DETAIL 46: 'Other' Detail Built -Up Applications and Modified Bitumen Systems Page -7 Process No. Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may eiti"sit Insert leaders indicating Roofing Component names, dimenaiaas, thickesses, etc. Include fastener type and spacing used for wood - blocking attaclunent Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may exisit Insert leaders indicating Roofing Component names, dimensions, thickesses, etc. Include fastener type and spacing used for wood - blocking attachment • A)i1t1i l > {{ tk(pJ +1r -C3 bi. 1•'L. i1vC.. 301 N.W . 71 STREW MIAML PL. 39430 Job Address: C4/1),i,qt 5. P Contractor Insert Building and Parapet Heights. (If no Parapet exists, insert M ") Also insert applicable information pertaining to the building below. (See ASCB 7 -88 Fact Sheet Attached ) Exposure Category: -- Classification Category. At Hurricane Oceanline ?: Y ✓N Basic Wind Speed at Building Location: 110 mph Building Condition based on 01 % of Openings: f /fie A GROUND LEVEL 1 feet X i feet BUILDING INFORMATION #1 Built -lip Applications and Modified Bitumen Systems Page -8 Process No. Job Address: t d/P/6 ., Contractor • CA meim woomotra .Thr • UM. ;MT BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Built-Up Applicationund Modified Bitumen Systems P*11 Process No r Job Address: to/W.f. 9? 4 Page -10 Roof System Assembly Product Control Approved: If N0, note any deficiencies: Design Pressure Requirements: Field: psf Perimeter Areas: psf Corner Areas: psf Note any limitations: 14"" ^`'^« FL,INC. 361 PI.W. T 1: a r ° gt Contractor FL " 31460 Process No. -- FOR PLAN EXAMINER USE ONLY -- Reviewed Details ?: Y N Notes: Built -Up Applications and Modified Bitumen Systems Y N C.ARAtj'fil 16.0010$ 3011'4.W.71 SIRE 1' M1A? .'PL 131.50 fob Address: ‘o/r,6; 9G 52 Contractor Process No. ea Reviewed Field Test Data ?: Notes: Additional. Notes: Built -Up Applications and Modified Bitumen Systems Page -11 Y N Plan Examiner 301 N.W. 71 STRarf Mf `OA 0 � METROPOLITAN DADE COUNTY, FLORIDA dig GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 �'ItOI)UCT nNTRa ialiCI, Off' AC('f PTANcE METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375-2901 FAX (305) 375-2908 Your application for Product Approval of GAF Conventional Built -Up Roofing Systems under Chapter 8 of the Metropolitan Dade County Codc governing the use of Alternate Materials and typcs of Construction, and completely described in the plans, specifications and calculations as submitted by Factory Mutual Research Corporation and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Department to be uscd in Dadc County, Florida undcr the specific and standard conditions set forth herein. The approval shall bc valid for a period of three years. The Building Code Compliance Department rescrves thc right to secure a product or material at any time for a jobsitc or manufacturer plant for quality control testing. If product or material fail to perform in thc approved manner, the Codc Compliance Department may revoke, modify or suspend the use of such product or material immediately. the Building Codc Compliance Department reserves the right to require testing of this product or material should any aniendincnts to the South Florida building Codc bc enacted affecting this product or material. The expense of such testing will be incurred by the Manufacturer. PRODUCT NO. : ACCEPTANCE NO.: 94- 1014.01 EXPIRES: NOV 101997 SAg C�D iamond, P.E. Product Control Division Supervisor - PLEASE NOTE - THIS IS THE COVERSIIEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. BUILDING CODE COMMITTEE Tltis application for Product Approval has bccn reviewed by the Metropolitan Dadc County Building Codc Compliance Department and approved by the Building Code Conjnittee to bc uscd in Dade County, Florida undcr the conditions set forth above. APPROVED NOV 1 0 1994 Charles Dangcr, P.E., Dirccto Building Codc Compliancc Dcpartmcnt Mctropolitan Dadc County r co Product Control Notice of Acceptance Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Category: Membrane Roofing System Sub - Category: Built -Up Roofing Type: Conventional S�Type: Fiberglass • Roofing System Approval Product Control No.: 94- .1014.01 Approval Date: Nov 1 0 1 9 9 4 Expiration Date: my/ 1 II 19' J 1 GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years, produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition GAF offers two ply modified systems to meet the demands for multi -ply SBS modified specifications. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the "GAFGLAS Built -Up Roofing Application and Specifications" manual published annually. The GAF Roof System Assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material Directory and the current Factory Mutual Approval Guide. GAF Materials Corporation products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. For more information on specific roof system constructions, contact the Technical Service Office, located in Wayne, New Jersey, at 1- 800 - ROOF -4I 1. William 1. Woodring Director of Technical Services 1361 Alps Road Wayne NJ 07470 (201) 628 -3000 ( I tamond, ! • Prod4ct GAF Asphalt/Concrete Primer GAF Fibered Aluminum Coating GAF Gaflite Roof Insulation Fasteners GAF Jctblak Flashtitc® Cement GAF Mineral Shield® Granules GAF Plastic Cement GAF Weather Coat® Emulsion GAFGLAS Ply 4® GAFGLAS Ply 6® Trade Names of Products Manufactured or Labeled by Applicant Dimensions Packing: 5 gallon pails, 53 gallon -- drums. Packing: 1 and 5 gallon pails GAF Jetblak All- Weather Packing: 1 and 5 Plastic Cement gallon pails. Packing: 1 and 5 gallon pails, 53 gallon drums. Packing: 60 Ib. bags. Packing: 1 and 5 gallon pails, 53 gallon drums. Packing: 5 gallon pails. 3' x 180'; Roll weight: 44 lbs.. 3' x 180' Roll Test Specifications ASTM D 41 ASTM D 2824 PA 114 ASTM D 3409 ASTM 4586 ASTM D 1863 ASTM D 4586 ASTM D 2178 Type IV ASTM D 2178 Gil Diamond P. E. Product Control No.: 94- 1014.01 Product Description GAF Asphalt/Concrete Primer used to promote adhesion of asphalt to dissimilar surfaces in built -up roofing. A cut back asphalt based protective coating containing leafing type aluminum pigment and inorganic fibers. Insulation fastener system. Available in a variety of lengths and styles. All- Weather Plastic Cement used to install flashing and may be applied on wct surfaces. Coverage: 1 gallon/14 ft.'. GAF JetblakTM All- Weather Plastic Cement shall be used for flashing applications only. A trowel grade cut back bitumen flashing -grade cement mixture, containing inorganic fibers and mineral stabilizers. Granules for surfacing of exposed asphalt, cold process or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. A trowel grade cut back bitumen standard -grade cement mixture, containing inorganic fibers and mineral stabilizers. ASTM 15 1227 Clay based emulsified asphalt coating with inorganic fibers. Typc IV asphalt imprcgnatcd glass felt for use in conventional and modified bitumen built -up roofing. Type VI asphalt imprcgnatcd heavy duty • i t ; GAFGLAS Stratavent® for nailable decks GAFGLAS® Base 3' x 108'; Roll Sheet weight: 75 lbs.. Weight: 52 lbs Type VI Dimensions: 3' x 36'; Roll weight: 69 lbs.. ASTM D 4897 ASTM D 4601 2 Gil Diamond, L Product•Control No.: 94- 1014.01 glass felt for use in conventional and modified bitumen built -up roofing. Heavy duty fiber glass base sheet impregnated and coated on both sides with asphalt with or without fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in asphaltic coating. • � / ; t t • m GAFGLAS® Mineral Surfaced Cap Sheet GAFTEMP GAFTITE® Base Sheet Fastener Gafglas® Flashing Gafglas® Stratavent® Perforated Ruberoid® 20 Ruberoid® 20 FR Ruberoid® Mop Granule Vent Stacks (metal and plastic) 3' x 108'; Roll weight 76 lbs.. various I' x 72', I'/i x 72', 3' x 72'; Roll weight: 25 lbs., 38 lbs., 76 lbs.. 39.4" x. 33.4'; Roll' weight: 90 Ibs. 39.4" x 33.4'; Roll weight: 90 lbs. 39.4" x 30.5'; Roll weight: 103 lbs.; Roll size: 100 R.'. ASTM D 228 PA 114 PA 114 Proprietary 36' x 3'; Roll weight: ASTM D 4897 60 lbs . ASTM D 5147 ASTM D 5147 ASTM D 5147 PA 100(A); UBC No. 52 -2; ASTM D 1929 (Plas.) & 635 (Metal) 3 Gil Diamond, P.E. Contra 1 No.: 94- 1014.01 An asphalt impregnated and coated glass fiber base sheet for use in conventional and modified bitumen built -up roofing. Asphalt impregnated and coated felt surfaced with mineral granules uscd as thc top ply in conventional built -up roof membranes. Polyisocyanurate foam insulation. Bascsheet fastener for built -up roof systems. Asphalt coated glass fiber mat flashing sheet available in three sizes. Heavy duty perforated fiber glass base sheet impregnated and coated on both sides with asphalt, with or without fine mineral stabilizer. Surfaced on the bottom side with coarse mineral granules embedded in asphaltic coating. Asphalt modified bitumen membrane, polyester reinforced for usc in conventional built -up roofing. Asphalt modified bitumen membrane, polyester reinforccd and treated for fire resistance, for usc in conventional built -up roofing. A heavy duty, resilient, asphalt modified bitumcn membranc, polyester reinforccd. Used in flashing applications for conventional built - up roofing One way valve vent uscd to relieve built -up pressure within thc roof system. GAF Vent Stacks are available in metal or plastic. % ft , % `! 2 .. j !...: %,r.., Nail -Tice Type R Fastener Trade Names of Products Manufactured by Others Product Dimensions Test Specifications Pyrox various AC Foam II various AC Foam -I various Roofgrip Fastener Hy -Therm AP various Hy -Therm Nail -Line various Hy -Therm / Pyrox / Various White Line Anchorbond Fastener PA 110 PA110 PA 110 PA 114 PA 110 PA 110 PA 110 PA 114 DekFast Fastener . PA 114 ES -30, ES -45, ES -60, PA 114 ES -90® Fasteners Product Descript ion Polyisocyanurate foam insulation Polyisocyanurate foam roof insulation Polyisocyanurate foam insulation. Insulation fastening assembly Polyisocyanurate foam insulation Polyisocyanurate foam insulation . Polyisocyanurate foam insulation Insulation fastening assembly Insulation fastening assembly Base Ply fastening systcm (lightweight concrete decks only) Product Control No.: 94 1014.01 Manufacturer Apache Products Co. Atlas Energy Products Atlas Energy Products Buildex Celotex Celotex Celotex Corporation Construction Fasteners Construction Fastencrs ES Products, Inc. PA 114 Insulation/base sheet ES Products, Inc. fastening assembly. 4 Gil Diamond, P.G. ISO 95 + Corpposite Vat ious AL MB Aluminum Roof Coating Gripdek Fastener Hexcet Fastener Hextra Fastener Tapcon ISO 95+ UltraGard E'NRG'Y 11 ISORoc Con -Tice Fastener Olympic Fastener CR -1.2 Base Sheet Fastcner various PA 110 PA 114 PA 114 PA 114 PA 11 PA 114 PA 110 Various PA 110 Various — PA 110 various PA 110 PA 114 PA 114 PA 1:14' 5 Galvanized steel Base Ply Fastener (Lightweight Insulating Concrete only) Polyisocyanurate / Perlite Roof Insulation Roof Coating Insulation fastening assembly Insulation fastening assembly Insulation fastening assembly Insulation fastening system Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam roof insulation Polyisocyanurate foam insulation. Insulation fastening system . Insulation fastening assembly CR -l0 coated galvanized steel fastener. Gil Diamond, P.E. Product Control No.: 94- 1014.01 Firestone Building Products Company Grundy Industries ITW Buildcx ITW Buildex ITW Buildex • ITW/Buildex International Pcrmalite Manville Roofing Systems NRG Barriers, Inc. NRG Barriers, Inc. Olympic Fastcners Olympic Fasteners Olympic Manufacturing Group, Inc. CR -Base Sheet Fastener CR -Base Sheet Plate GlasFast Fastener Glasfast Striker Fastener Paroc Multi -Max Insulfixx Fastener Plate Fixx Fastener Rawl Drive Rawl Spike Fastener Rawlite Fastener T -Fast Tru -Fast Fastener ASTM D 312 roofing asphalt various various PA 114 ASTM A 525 PA 114 PA 114 Insulation fastening system Owens - Corning PA 110 PA 110 PA 114 PA 114 PA 114 PA 114 PA 114 PA 114 PA 114 ASTM D 312 CR -l0 coated galvanized steel fastener. 2.75" galvalume steel stress plate Insulation fastening assembly Non woven fiberglass mat insulation. Polyisocyanurate foam insulation. Insulation fastening assembly Insulation fastening assembly • Insulation fastening system Insulation fastening assembly Insulation fastening system Steel/Wood fastening assembly Insulation fastening assembly Product Control No.: 0- 1014.01 Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Owens - Corning Partek, Inc. RMAX SFS /Stadler SFS/Stadler The Rawlplug Company, Inc. The Rawlplug Company, Inc. The Rawlplug Company, Inc. Trinity Engineering, Inc. Tru -Fast ASTM D roofing asphalt. generic / , L , • : • Gil Diamond; P.E. Product Control No.: 94- 1014.01 ASTM D 41 Primer ASTM D 41 Asphalt Primer generic Fiberglas PA 110 Fiber glass roof insulation generic de Gypsum Sheathing . Various PA 110 Gypsum Sheathing used in generic specific Roof Insulation Assemblies High Density Wood various PA 110 Wood fiberboard generic Fiberboard insulation. Nails ASTM A 641 Min. #12 corrosion generic resistant annular ring shank nails, FF- N- 105 -B, Type 2 Perlite PA 110 Perlite insulation board generic Red Rosin Rosin paper for barrier generic layer on wood decks Tin Caps 1 5/8" - 2" Min. .010" (32 ga.) x 1" generic corrosion resistant disc 7 � i• Gil D( P.E. Test Agency Test Identifier Test Name/Report Date Factory Mutual Research FMRC 1994 Current Insulation 01/01/94 Fastening Requirements FMRC Approval Guide 1993 Factory Mutual Research J.I. # OT4A.I.AM Uplift Approval 08/26/92 Corporation J.I. 0Y9Q5.AM Wind Uplift 0729/94 Underwriters Laboratories, R1306, 87NK11819 Class A Fire Classification 01/01/93 Inc. Test Reports J.I. # IV8A4.AM Uplift Approval 06/28/93 J.I. # 1RIA6.AM Uplift Approval 11/15/91 J.T. # 0T2Q4.AM Uplift Approval 10/17/91 J.I. # 0Q6A6.AM Uplift Approval 07/16/91 FMRC Current Insulation 01/01/94 Fastening Requirements FMRC Approval Guide 1994 J.I.3X3A2.AM Wind Uplift 08/02/94 8 l /cif Gil Diamond, t' / E. Product Control No.: 94- 1014.01 Insulation Types: Basalt Wool Perlite Polyisocyanurate Composite Board Wood Fiberboard High Density Wood Fiberboard Rockwool Maximum Design Pressure Material Design Pressure Wood -G0 psf Steel -45 psf Concrete -90 psf Lightweight Concrete -45 psf Cementitious Wood Fiber -45 psf Poured Gypsum Concrete -45 psf Maximum Fire Classification Material Classification Wood Class'A' Steel Class'A' Concrete Class 'A' Lightweight Concrete Class 'A' Cementitious Wood Fiber Class 'A' Poured Gypsum Concrete Class 'A' Product Control No.: 94 - 1014.01 Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Undenvriters Laboratories Roofing Materials Directory for Fire Classifications. Gil Diamond, P.C. / (, ;% r tY 9 Deck Type 1: Wood, Non - insulated Deck Description: "/ or greater plywood or wood plank decks System Type A(1): Base sheet mechanically fastened. m All General and System Limitations shall apply. Base Sheet: Cap Sheet: Surfacing: (Required if no cap sheet is used) Install one of the following: Maximum Design Pressure: -45 psf. Maximum Fire Classification: 'A'. See General Limitation #2. Maximum Slope: 3 ":12 "; See General Limitation O. Specification No.: None 20 Product Control No.: 94 1014.01 GAFGLAS® #75, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS® STRATAVENT® or RUDEROID® 20 applied to the deck with approved annular ring shank nails and minimum 1 V," tin caps at a fastener spacing of 12" o.c. at the lap, 18" o.c. in two rows staggered along the center line of the sheet in the field. Ply Sheet: Two or three plies of— GAFGLAS® PLY 4® or GAFGLAS® PLY 6® ply sheet adhered in a full mopping of approved asphalt at an application rate of 25 lbs. /sq. ± 15 %. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt at an application rate of 25 lbs. /sq. ± 15 %. I. Grundy AL MB aluminum Roof Coating with an application rate of 1.5 gal. /sq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal./sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel 'or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively.' %) // Gil Diamcmd, P.E. • ' Deck Type 1: Wood, Non - insulated Deck Description: 19 / „” or greater plywood or wood plank dccks System Type A(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Base Sheet: • Ply Sheet: Cap Sheet: Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: Product Control No.: 94- 1014.01 GAFGLAS® #75, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS® STRATAVENT® or 20 applied to the deck with approved annular ring shank nails and minimum I S /," tin caps at a fastener spacing of 9" o.c. at the lap, 12" in two rows staggered along the center line of the of the sheet in the field. -55 psf. Two or three plies of GAFGLAS® PLY 40 or GAFGLAS® PLY 6® ply sheet adhered in a full mopping of approved asphalt at an application rate of 25 lbs. /sq. ± 15 %. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt at an application rate of 25 lbs. /sq. ± 15 %. (Required if no cap sheet is used) Install one of the following: I. Grundy AL MB aluminum Roof Coating with an application rate of 1.5 gal. /sq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibercd Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. 'A'. See General Limitation #2. 3 ": 12 "; See General Limitation #3. GiI Diamond, P.E. 2 l /1 - Wood Deck System Limitations: Product Control No.: 94- 1014.01 A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to plank and deck. Red rosin sheet may also be installed on plywood decks as an option. 2. A slip sheet is required with PLY 4® and PLY 6® when used as a mechanically fastened base or anchor sheet. 3. Pre - assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. Pre - assembled 'Cap Nail' shall not be used for base sheet attachment Gil Diamond, P.C. 22 _ .',.1",•^44',. Per NO. STATE OF Florida COUNTY OF wade a. Name and address 5. Surety N/A Public NREPARED BY: STATE OF FLORIDA COUNTY OF DADE I HEREBY CERTIFY that this is a true copy of tf:3 original filed in this office on_/ clay of , A. D. 19( l . ---- WITNESS my h ad and O;ricial Seal. Clerk Circuit Court BU a. Name and address b. Amount of Bond $ 6. Lender (name and address) N/A NarICE OF COMMENCEMENT Catherine A. Duffin 4209 Jackson St. Hollywood, FL 33021 D.O. Miami Shores Presbyterian 602 N.E. 96th St. Miami Shores, FL 33138 Church 92R 164216 1992 MAY 01 14:03 TAX FOLIO NO. 11-3206-017-1700 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in the Notice of Commencement. 1. Description of property: (legal description of the property, and street address if available) . Miami Shores, FL 33138 2. General description of improvement Reroof entire chappel, new Gory tile color throughout new gutters & downspouts 3. Owner information b. Interest in property Owner c. Name and address of simple titleholder (if other than Owner) 4. Contractor (name and address) Obenour Roofing, Sheet Metal & Supply Co. 7357 N.W. Miami Ct. Miami, FL 33150 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (1) (a) 7., Florida States (name and address) James D. Obenour 7 3 5 7 N.W. Miami Ct. Miami, FL 33150 8. In addition to himself, Owner designates James D. Obenour of Obenour Roofing to receive a copy of the Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. 9. Expiration date of notice of commencement (the expiration date is 1 year from the date of recording unless a different date is specified) 7 subscr' • -• before me this 2 8th day of April ,19 9 2 Retry Public State of Florida My Commission ExPiret Commission Expires Feb. 18,19 MI MI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the appro of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This a lication is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the&Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address ..71 . n .� ate e ® I - - - - - - - .. _. - -- - -, 19 =`s-s c!'r.!.- No.__6_0 _ - Street_. _%_4_ Registered Architect and /or Engineer _ Name and address of licensed contractor____ i. Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done (: [ ) J • l State work to be done and purpose of building (by floors) aixak, and for no other purpose. New Building 4/ Remodeling Addition _ Repairs P No. of Stories / -- - �� To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $____ X.- �• Amount of Permit $__f O ' e Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to__ The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcor actors, work jo be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared • PL NG BOARD Notary Public, State of Florida to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the therein by him stated are' of the above described Fonstruction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts hve. Permit No lD I (c. Date ^ 3 °'" Read, Sworn to and Subscribed before me. Disapproved __ -__ Date ' •(Signed) - Building Inspector A \ My Commission Expires _.DATE Chairman Member Member _ Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. materials and /or workmanship. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty PI 4 IT APPLICATION: FOR MUNICIPALITIES OF DADE COUNTY (OWNER TO'RETAIN COPY) Date 4/2 Job Address 601' 96 St. Miami, - Fla. 33135 Tax Folioll- 3206 -017 -1700 6 53 42 Miami Shores Sec. 4 AM D "PB, Lots .11 thruu BLK Legal Description. Lot Size 435.030 X 1 0% i F "Master Permit #•3` Owner / Lessee / Tenant Miami" Shores . Pr'esbyter'ian Church Owner's Address 602. N.E. 96th .STreet Miami Shores, FL P W8 Obenour .Roofing,S /M & Supply Address 7357 N.W. Miami Ct. Miami, FL 33150 Contracting•Co. Qualifier James D. Obenour ' sg # Phone 757 -2612 CC0014306 •0006454 USEF SIF State# Competency# Ins. Co. Capital Asourancc • Architect /Engineer Address Bonding Company N/A .. • Address . Mortgagor N/A Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL PAVING FENCE SI( WORK DESCRIPTION CHAPEL ROOF ONLY- Reroof entire entire chapel roofing and install new Gory'smooth.tile.,color throughout and new gutters Square Ft. 3200 Estimated Cost $19,000.00 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE Z DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YC INTLND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). . Application is hereby made to obtain a tc cio work and installation as indicated above, ar on tae attached addendum (if applicable). I certify that all work will be performed to meet tt staniards of all laws regulating construction in this jurisdiction. I understand that separat permits'are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING, and MECHANICAL work. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all vox will be done in compliance with all app3 Icahle laws regulating construction and zoning Furt::iermore, I authori th bove- ntuneu c:oc.ic ucLor to do t to work stated. Signature Date: Owner and /or Condo President 4/28/92 APPROVED: gnature of Contractor or 1 ner- Builder Date: 4/28/9.2 Electrical Nota:.y as to Ower andl - � y My ������� ���� Notary as to Contractor or er -B a 1 d y Commission Fxoires M : i Cormi i : �ltplr (b. fl8, i98 My Commission Expires . � VAlie Side O r d * * y mmission giros Erb* 1��� * PERMIT FEE: Fire Other 1302. . Mechanical Plumbing.. Engineering /,6W BUILDING ❑ MIAMI SHORES VILLAGE, FLORIDA PLUMBING ELECTRICAL 0 PERMIT N° 8417 ROOFING 0 Owner of Building 44;; Architect Contractor or Builder Legal Description Address of Building Lot This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. Signed ° ' • ,. (INSPECTOR) BY • In consideration of the issuance to me of this permit I agrge,to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, tatements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR or BUILDER Date L 1 1 191.0 Contractor's License No BY AUTHORITY Work to be performed under this Permit ' ti ''`�* 4 ` IrY Subdi- vision Sq Ft Value of s °' Amount of J Project $ « � � Permit $ �° MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plank and specifiitions must be kept at building during progress of the work. ��pp�� / (/ub < ?�JJJ v�C'o ✓ �.; - uL�'' C' ���a2, �' ),),PA.? 0 _ _ Gds I "° FD / , 19 Owner's Name and Address. A, //y9g1./ /.. QfZ ‘44.5:27.60. No /QCI.Q Stree _ .. £ , __ _._ Registered Architect and /or Engineer. . ‘ 65e .% Name and address of licensed contractor O,9D/1L 7.7. - .C2122Y./Zv eP/9/V Ji ,,/l p 6 67$x(63. Location and legal description of lot to be built on: tSD / /S, 7S s7 Lot Block Subdivision Street and Number where work is to be done. 0/ N. 5 G State work to be done and purpose of building (by floors) / a f 'W 6 'T.. &T7- and for no other purpose. New Building Remodeling. Addition Repairs No. of Stories ryy � b� To be constructed of Kind of . Roof Covering 6 d) r) - Estimated Total cost of improvements $. .. .7L�__. Amount of Permit $_.� ,22 d Zone cubage required _Plan Cubage Distance tonext nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such su ontractors, on wor t _o he .rtned under this permit, as are licensed by Miami Shores Village. Remarks (Signed STATE OF FLORIDA, COUNTY OF DADE. J ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No 0 ,/ Date ° Read, Sworn to and Subscribed before me. Disapproved pate. ..__.___ (Signed) � _ .. � �n_� �, �, � =_ Notary Public, State of Florida Building Inspp for My Commission Expires LANNING BOARD DATE Chairman .. Member Member Member Member .. Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 81.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.