Loading...
546 NE 97 St (17)Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with. whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date / � . 19 f Owner's Name and Address No. (14 Street NE q7 5 1" Name and address of licensed contractor 6ddeta St kecha J2'cez ( 111 c 1f726 IV /M ha, Rye ) //�7 rL 33/6Q Registered Architect and /or Engineer Location and legal description of lot to be built on: Lot l/ 4/5— Block APPLICATION FOR BUILDING PERMIT (YUrch es 9 Street and Number where work is to be don <7/ MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT Subdivision Remarks (Signed) / ,/ /4M) r , .pf 1 State work to be done and purpose of building (by floors). state exterior colors (submit samples) tea 1 IQC e• , / o F - 0 Re /- Cycle co nd evtsinq On,7` • and for no other purpose. New Building Remodeling Addition Repairs No. of Stories____ To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements S _ S. % Amount of Permit $ ✓ l 64 " { Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligatons as an employer of Labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof. and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit: and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors. on work to be performed under this permit, as are licensed by Miami Shores Village. 2 (5f STATE OF FLORIDA COUNTY OF DADE. } ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well {nown, and who. being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same. and that all facts therein by him stated a •e true. Permit No. i! Date Its 4 Read, Sworn to and Subscribed before me. Disapproved y Date Notary Public, State of Florida (Signed) Building Inspector My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $25.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $25.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and workmanship. 4 -;"/-7 MGA 1I SHORES VILLAGE .DING INSPECTION DEPARTMENT APPL [1!r','TION FOR RUILDIA5 PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date --- - -_.21 ' < }� ,19 " L. r -- Owner's Name and Address /74's... __ 1 �C/`1 No. ✓z?` Street-.tV . • __ % .. Registered Architect and /or Engineer .... . ..... .. .. .. _ Name and address of licensed contractor .5 4e.RA_ .i s sue/ /24,1/14-1A10 n Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done ..57.4 . / State work to be done and purpose of building (by floors)._ _.. _ l' _ _C__E }/T4rY___._� "�%?` _ � 4,/ and for no other purpose. New Building Remodeling. Addition._. Repairs No. of Stories To be constructed of Kind of foundation Roof Covering.... ........ .......... .................. Estimated Total cost of improvements $._ � " C' t' • 41 / 4 ' Amount of Permit $ Zone cubage required _Plan Cubage,___ _. Distance to next nearest building__. ___ _ . Size of Building Lot__ Maximum live load to be borne by each floor-__ The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen s Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on wor ' cr be performed under this permit, as are licensed by Miami Shores Village. Remarks__ ________ _ _ __ -- .- - - -- (Signed)_ I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. �J Permit No D r - -- - Date e I� - _ 7 0 Read, Sworn to and Subscribed before me. Disapproved - _ Date -------- (Signed) L . Buil nspector .Commission Expires Chairman Member Member . - Council Approved Notary Public, State of Florida PLANNI BOARD __. DATE Member Member Member _._.- Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has h obtained front. the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for insp&., lion or faulty materials and /or workmanship. Amount of Permit $ MIAMI SHORES VILLAGE ELECTR ICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT (' Permit No. Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building o: other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, i?iu .nda, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address ,C.: /.�S � . C/� i t No•• 1 /4 Street..A/ • 92.nS'T. -••• ••••- Registered Architect and /or Engineer Employing Electrician's Name..... (/0./113 4. .29PES ,a Jt/G No. J .4'4 Street.,. �Gt�l�.. .yf _a�s •• Location and Legal Description Lot Block Subdivision Street and Number where work is to be performed —No .�R�NiF • Street State work to be performed and purpose of building (By Floors) l40 ,9kvi 97/S/ New Building Remodeling Addition Repairs No. of Stories Service Over Size Feeders Conduit Main Sw Amps Main Fuses . Amps Underground Type of Installation— Conduit Tubing B.X.L Metal Moulding The undersigned applicant or this building permit does her eel tify that understands and .ccepts his 6 igations as an employer of labor under the Florida Workmen's Compensation Act, being S on 5966, Compiled General Laws of Florida Permanent Supplement, and has complied with the provisions thereof, and will require s'. ar compliance from all contractors or sub-contractors employed by him in the work to be performed under this permit; and will post or c.; to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. . (S (Signed) Date e¢trical Inspeztor. Master Electrician. STATE OF FLORIDA, l I ss. COUNTY OF DADE. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, and he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. My Commission Expires Notary Public, State of Florida NOTE: A re•inspection fee of $1.00 will be made when such re-inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. SWITCH OUTLETS LIGHT OUTLETS PLUO RECE'P'T'S FIXTURES NO. LAMPS REFRIO. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. WATER HEATER W. HEAT. CONN. SPACE HEATER STRIP HEATER TOTAL CONTR. LIST CHECK ENT. SW. DIST. CAB. SERVICE TCMP. SERVICE PERM. MOTORS 0.1 HP MOTORS 1.5 HP N EON TRANS. RADIO TOTAL CONTR. LIST CHECK Amount of Permit $ MIAMI SHORES VILLAGE ELECTR ICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT (' Permit No. Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building o: other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, i?iu .nda, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address ,C.: /.�S � . C/� i t No•• 1 /4 Street..A/ • 92.nS'T. -••• ••••- Registered Architect and /or Engineer Employing Electrician's Name..... (/0./113 4. .29PES ,a Jt/G No. J .4'4 Street.,. �Gt�l�.. .yf _a�s •• Location and Legal Description Lot Block Subdivision Street and Number where work is to be performed —No .�R�NiF • Street State work to be performed and purpose of building (By Floors) l40 ,9kvi 97/S/ New Building Remodeling Addition Repairs No. of Stories Service Over Size Feeders Conduit Main Sw Amps Main Fuses . Amps Underground Type of Installation— Conduit Tubing B.X.L Metal Moulding The undersigned applicant or this building permit does her eel tify that understands and .ccepts his 6 igations as an employer of labor under the Florida Workmen's Compensation Act, being S on 5966, Compiled General Laws of Florida Permanent Supplement, and has complied with the provisions thereof, and will require s'. ar compliance from all contractors or sub-contractors employed by him in the work to be performed under this permit; and will post or c.; to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. . (S (Signed) Date e¢trical Inspeztor. Master Electrician. STATE OF FLORIDA, l I ss. COUNTY OF DADE. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, and he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. My Commission Expires Notary Public, State of Florida NOTE: A re•inspection fee of $1.00 will be made when such re-inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. Disapproved (Signed) Chairman Member Member .- y ,r MIAMI SHORES LLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date , 19. Owner's Name and Address . 5 • ¶( tr' N ° � '- Street_.,A Registered Architect and /or Engineer Name and address of licensed contractor tt' rt :'k'. � n., ; Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done .�P) � 1 e--- ' , • ' State work to be done and purpose of building (by floors ose P P g ( Y ) and for no other purpose. New Building Remodeling Addition - -. A <' !)(,' Repairs No. of Stories To be constructed of Kind of foundation Roof Covering Estimated Total cost of improvements $ 1 -1 s 0 •=— Amount of Permit $ Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of lbe work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors,;-+on, work .tot - performed under this permit, as are licensed by Miami Shores Village. ` i c� work �i Ji Remarks ( Signed) ,, , ?4 v._'` - STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated arf true. Permit No '2 t "' Date .t � �� Read, Sworn to and Subscribed before me. Inspector Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or fau`ty materials and /or workmanship. MIAMI SHORE V LAGS OS BUILDING DEPARTMENT 41 305 -795 -2204 Building Inspection Request Type Insp'n Permit No. P. L 0' L Name r cJE-� Address ° "i Company • Phone # Inspection Date Approved Correction Re- Insp'n Fee MIAMI SHORES VILLAGE BUILDING DEI',ARTMENT 305 .1z04 Buildin Inspection Request Date. E. q Type Insp'n 17-1 0 t C Po Permit No. k LJ.J"'i Name . s Address 57gL N cr7 Company pl P C OL� Phone # Inspection Date Approved Correction Re- Insp'n Fee 6 Ac /27 a,O 3 19,A.., GENERAL Shutters shall be the all - aluminum ISLANDER, (Bahama /Sarasota) style, as manufactured by WILLARD SHUTTER CO., INC., Miami, Florida, where indicated and as detailed on the drawings. CONSTRUCTION Shutters shall consist of a series of 1 -3/4" wide fixed louvers inserted into interlocking box -beam frames, 1 -5/8" thick and 2 -1/2" wide. Louvers shall be rolled with a converse beveled edge and spaced in 1 -1/4" height increments. Louvers may span a maximum of 26 ", at which point an additional box -beam shall be required as an interior frame support (mull). Each box beam shall be packed with styrofoam to firmly receive the louver and add structural soundness to the frame. Heavy duty extruded aluminum I -beams shall be inserted into box -beams for additional reinforcement as re- quired. •OPERATION Shutters shall include a continuous, reversible, extruded aluminum header as a top- hinged mounting device. Shutters shall be supported by means of telescopic adjustable arms (or: fixed arms with the shutter projected at an angle of °). The arms connect to rod brackets on the underside of the shutter and to the camelbacks mounted to the existing structure. The shutters shall include arms which can be disconnected to facilitate lowering the shutter into the closed position (or: the shutters shall include arms which are attached permanently in order that the shutter may remain in a fixed position at all times. MATERIALS Box -beam and louvers shall be 3004 -H36 roll- formed aluminum .025" thick. Styrofoam shall be Dyplast expanded poly- styrene insulation to meet Federal Specifications HH- 1 -524A. I -beam inserts shall be 6063 -T6 extruded aluminum, .062" typical wall thickness. All fasteners shall be self- tapping stainless steel machine screws or pop - rivets, aluminum alloy 2024 -T4. Header hinge, tube supports, tie -down straps, and camelbacks shall be aluminum alloy 6063 -T5. FINISH Box -beam frame and louvers shall be roller- coated baked enamel in a medium gloss as selected from manufacturer's standard colors. (Special finishes available subject to inquiry.) I -beams shall be mill finish. All other alum- inum extrusions shall be anodized R1 -201. PAGE 4 SPECIFICATIONS rum ALLOT COMPRESSION YIELD STRESS 8OI EA►N. Looms HANGER BEAM BOLTS RI VETS mai MI168 TU= meow, cmir.mACE po4-836 60 T6 202-T4 6063 - 25 000 25,000 38,000 16,000 f .o::a' e :'.. h .II I v . Y:I4 SPIN #40 25 2" lI O rr— I I IJ DETAIL -(I iClM NM= Mr MA NM= KINIJI WW1 MIMI INVIANN MACAO FGl• wawa iwimwsmo ASE GROUND o 5' 5 - 15' 15 - 25' 35 5 55 - 6o LOUVER SPAC IIO CLLR ALLOWABLE PSOJOCTION SCHEDULE 132=IOI( BEM BOX 811•0 9ANGER OILY 8 A11 ONSIDE BOX - U 0LIE ECIRTPEEPLEn F� CZ. mourn =Ira EMITS i & MTIA � f•' =maisa sauna 0zv2I1 war • 1 •; ■1afE� t$ Ti ■.�18�F 5' - r iTii1� MEAN EEEEEE� m f.' E]i Ei»II� f�� llr li■�il1r.IE :0s • E■= Fla ■R,Zy =E . �s3i EI>�DII E�1iEIa11� L ! - stigI•1 =MA 1111 ITS WW1 EEt>;I rim , -2 ULM IL' - .o 5' -n It' - 0' 5 -0• 6'-o• 8'-6' MAXIMUM RAC DIG SDI LEAN 0E 4' -1G' 4'-'" 4' ' 0 ' 3' -s' 3'-3' BIZ: :AIR RLWCEB 821* S - 6" co - 9 " 4' - 10 4, - 8" 6 - 4" '1 e ca • N. C 1 1 1 a A.- 26' MAX D A 1021 SUPPORT SPACING - ass SCHEDULE SCHEDULE FLED OR AD,'. ARM SUPPORT ( 2' C ISL Affi.BAC1 .109" TRICE DEjAIL- A 4" - 4 - I./8 BOLT POP RriEPS USE I -BEAM MIRES - AS SHOWN 21 P L A N • DETAIL- E FOR 2110 FLOOR & HIGHER 1/8" POP 8111TS 32' 0/0 STAGGERED QTR 2 AT EACH 7)D MRYROVCIAII SECTION -C C 2ITI SIAM INSERT ISL 134 (AD2) AWN. SOS 0.84' 0.D. .109' WALL I1YL00 C PIN LOCKING RING A DETAIL - 8 SECTION - 88 0. e ammo c 41 - TO LOCI SNOTINE I1 STOEN POSITION, SUPP , =MOVE 0T s SECTION- A A DOWN AND LOCI IN POSITION AS SHOWN in D11TAII. • D" 0E 'I' 3OTE: THIS SHUTTER DOES NOT WAVE TO B6 CLOSED DURING A HURRICANE STAR 'TAIPII" 0 1/4 z 7/8" • 3 0/0 1/8" POP RIVETS / CAUIEING 4 EMI' D - J BOX BEAM ISL 112 ISL 113 (PUNCHED) LOUVER SECTION - CC HEWER sacs co5IDGDm 1/8" POPRI 5' C /C- STAOOERIU DETAIL- C 1,(8' POP MIVET8 C /0- STACCERBD WITH 4 AT EACH END COT 00? FOR LOUVER .062• .312. HANGER BEAM LOUVER ISL SECTION - DD AWL STRAP 1" 2218, .060' MICR 2H sun "isms% /4025 1-1A" I'r DETAIL - D' FOR FIRST FLOOR ONLY HEADER ISL 100 HINGE ISL 102 T /6" TEICE WASHER DETAIL ISL 151 EPDXY 0PT201ALi /6 8.1.3. • 6' 0/0 150XY ON ALL POUR SURFACES TYPICAL EPDXY DETAIL DESIGN N � ILD Lokrs ARE I:: ACCORDANCE 7 /1.3 SEC.IQ 2306,2 0D :RE SOUTH FLORIDA BUILDING CODE. ^_ES^. LOAD: 1.5 X DESIGN LOAD GOOM.TDD1Si 5.0 TINE= DISI01 LOAD ALLOWABLE DOI81'I01, MAIM IBS LAIRD SWN0IDABR �� PROM TEST LOAD AMIN C: • AS DESIGNED HE THE LIMNS/UN�ASSOCIATION. ffi8Q24Y 1.1. SPECIP C8 2 8 E - -524, TYPE ORAL SOT= IRIS ammo WAS >ESICIID A000RDA1CI RTE THE E811OPOLITAI DDE COUNTY WILDING AND 8017EG DEPWRIME1T POLICY, DATED SHPT. 1, 1967, BASED 01 THE SOUTH FLORIDA BUILDING CODI. L'ASOMYC A ::C O.RS OP T1D7 SALE QUALITY & STRENGTH 402 EE S:':5 - "•ED FOR THE ANCHORS SHOWN. ( :BIRO APPROVED) THE BOX MAX TO EE PASSIM TOGETHER 12TH I -HUMID TIPS 1204 EPDXY OR 06 =LP IAPP13O NACHII■ SCRUMS. 1/8 L1. POP arms NAY 81 SUBSTITUTED IITH 06 SELF TAFFIES MACHINE SCREWS. PRINTS VALID FOE BUILDING IIPARTEMIT PURPOSES EMILY meg 82ORID SI THE INOTIEER OVIM ID ELL. PEYISED AUG 73 DELETED 1 BEAM RE /ISED MAY '70 REVISED JAE'c9 Revised Nov.',7 ADDED BA11080 BEAR SPANS ADDED HANGER BEA:.i, PART NOS. &MISC OOMIYCIM ..ALL WNW, ALL O•10MI01. AT ells WORK "'1o®M wn1 -. Added Projection Schedule W I L LARD SHUT ER CO. MIAMI FLORIDA CARR SMITH Al ASSOCIATES CONSULTING ENGINEERS. MIAMI ILJDA PA= /N I0I*,J1 IN Imam mA. IOMOI DS 1 Pa: HO. 9 1 sHSST Ha 1.67,I /of 1 The Islander GENERAL SPECIFICATIONS Shutters shall be the all - aluminum ISLANDER, (Bahama /Sarasota) style, as manufactured by WILLARD SHUTTER CO., INC., Miami, Florida, where indicated and as detailed on the drawings. CONSTRUCTION Shutters shall consist of a series of 1 -3/4" wide fixed louvers inserted into interlocking box -beam frames, 1 -5/8" thick and 2 -1/2" wide. Louvers shall be rolled with a converse beveled edge and spaced in 1 -1/4" height increments. Louvers may span a maximum of 26 ", at which point an additional box -beam shall be required as an interior frame support (mull). Each box beam shall be packed with styrofoam to firmly receive the louver and add structural soundness to the frame. Heavy duty extruded aluminum I -beams shall be inserted into box -beams for additional reinforcement as re- quired. OPERATION Shutters shall include a continuous, reversible, extruded aluminum header as a top- hinged mounting device. Shutters shall be supported by means of telescopic adjustable arms (or: fixed arms with the shutter projected at an angle of 0 ). The arms connect to rod brackets on the underside of the shutter and to the camelbacks mounted to the existing structure. The shutters shall include arms which can be disconnected to facilitate lowering the shutter into the closed position (or: the shutters shall include arms which are attached permanently in order that the shutter may remain in a fixed position at all times. MATERIALS Box -beam and louvers shall be 3004 -H36 roll- formed aluminum .025" thick. Styrofoam shall be Dyplast expanded poly- styrene insulation to meet Federal Specifications HH- 1 -524A. I -beam inserts shall be 6063 -T6 extruded aluminum, .062" typical wall thickness. All fasteners shall be self- tapping stainless steel machine screws or pop - rivets, aluminum alloy 2024 -T4. Header hinge, tube supports, tie -down straps, and camelbacks shall be aluminum alloy 6063 -T5. FINISH Box -beam frame and louvers shall be roller- coated baked enamel in a medium gloss as selected from manufacturer's standard colors. (Special finishes available subject to inquiry.) I -beams shall be mill finish. All other alum- inum extrusions shall be anodized R1 -201. PAGE 4 PARS ALLOY COIPNSSIOE YIELD STRESS BOX SIAM. LOUVERS HANGER BEAM BOLTS RIVETS BRAUER SINGS TUBE SUPPORT, CAMBLEACK 3004-136 6065 2024 636 3- 7 5 28,000 5 38,000 16,000 , • ISL 123 '1 L, �.. !PAMPIN' S ;/e•z1 -1/4 DETAIL- A " -- ' 4 - 1/6 BOLT POP Rr.'ETS • I 1 1. . 14TALU'IN e4w 2" 1¢1: ISL 13 A �I A ., R -- s � rE tI- Ijl INTIM 113Z:lA MAMA INSTLIAR AFB f1 GROUND LOUVER SPACING CIGAR AL OWAI*A PU0/ICTION SCNEDUL( IMAM.. BEM OUTSIDE BOX BOX - BEA): 9ANGS1 BEJ. 0 "LY B-AJ ONLY EDILTEA MFAtl VEMI:11 It. , • G - 5' HE= E . ERE K. TA REIM minx WIZ Mal MEW II M MI ii:Mn _1_ RIAC:umEEC s mac ' i="._ R 3l1SA E11■1111.2RT•TP M1151 15 - 25' MGM ■M= MINIIIIF.aC214 : AMIM MEW MIN 5 - INFAMI ��� • !l11i11 %Ma EQ :112M • 2 ML Ma■M ENA MIMI•. 35 - 5 �� IMMO t - - .IDSO2�l! t1 EZMIME Llr i ' MigMEIMMWMI 55 - EMMA L 1XI t' 'o 5' -11 1-2 r PIDJEO?IOIE • k` 5' -0" 6'-0• BOX EHA1 1174 OILY HANGER DUX 4 -10 4'4" 4' - 0" 3'.8• 3'-3 s• - 6" s , - s • )' - 10" li, - QA - 4' • 6. 0/C CARR SMITH 01 ASSOCIATES CONSULTING ENGINEERS. MIAMI IL 1 "o. 1 INERT HD. N C9 1 7 26 MAX - D TUBE SUPPORT SPACING- BEN SCHEWI.a A FIXED OR ADO".STkBLE ARM SUPPORT f. CAIES.BACE .109" THICK 2" KIN. DETAIL- E FOR 211D FLOOR k HIGHER 4/8° POP RIVETS 12' 0/0 STAGGERED 1115 2 AS NCH EN SECTION -C C WITS BEAM INSERT USE I -BEAN INSERTS - AS SHOWN IN P L A N ISL 134 (ADJ) ALAS. TUBE 0.84 O.D. .109' NAIL THIS SHUT?ER DOES NOT RAVE TO BE CLOS?.D DARING A HURRICANE STAR "TAXED!" #4015 /4 z 7/B' • 36 0/0 CAULKING HEADER HIRES CONTINUOUS UYLOL C PIE LOCKING RII:G A DETAIL - B SECTION - BB SHUTTER CEO/1N17 , 10 LOCK SHUTTER If ETON P0311101, SUPPORT, A RI SECTION- AA D0111 AND LOCK IN POSITION EN MIN 11 wan "D" OR 'R HOTS: 1/8 POP RIVETS 4 RR'D a yB raz. I TAI R t) �ME SOMAS CR DETAIL -A PZOD ADJUSTABLE LOUVER BOX BEAM ISL 112 ISL 113 (P_INCHED) SECTION - CC 1/8' POPRI 5" C /C- STAGGERED DETAIL- C l r POP RIVETS ,•c/0—STAGGERED WTID 4 AT EACH END COT OUT FOR LOUVER .062" .312 HANGER BEAM LOUVER ISL 176 ISL 114 1 SECTION - DD Awl. MAP 1' WIER, .060• THICK 1/9. 10t ti 2 8153 own • 1-1A• -- DETAIL - D 'ASM FOR FIRST FLOOR ONLY HEADER ISL 100 HINGE ISL 102 1/6" ' WASHER DETAIL ISL 151 - Epos RE/ISED MAY '70 REVISED JAK'c9 Revised No7.'67 IRMA SO t0a OPSIOIALi /6 S.E.S. • MAXIMUM SPACING ADDED MEAGER BEAL SPANS Added Projection Schedule Th. IsI.n /or E ros 01 ALL POUR SORPACE1 TYPICAL EPDXY DETAIL DESIGN WIND ARE II: ACCGRDANC1 W1.11 SECTION 2506.2 OD 1HE 30000 FLORID:. BUILDING CODE. TEST LOAD: 1.5 X DESIGN LOAD COENI.TID13, 3.0 TARS DESIGN LOAD - hLLOIAHLR DETLECTDn: YIN =DIEM 1,80 SECONDERS !� RECOVERY FROM TEST LOAD ALOIREERO1 ALW! OF MUG COMPONENTS, AS UNSIGNED IS THE AL01mN1 ASSOCIATION. 8 P0*1: PEL SPICIPICASIO118 HH -1 -524, TYPE II, CLADS 2 OH EQUAL. JEMEKRAL NOTES IBIS SHUTTER WAS DSSIGNED'11 ACCORDANCE NITS TEN RRTROPOLITAI DAIS COUNTY BUILDING AND EOEING 1NiPART101N? POLICY, HATED SEPT. 1, 1967, HASID 01 THE SOUTH FLORIDA BOILDINO CODS. LASO :10C :.::0 :OILS OP THE SALT QUALITY & STRENGTH 181 BE S:- :.S - """ED FOR TES ANCHORS SHOW!:. (:£TRO :.2PR07E2) THE BOX BRAN TO BE FASTENED TOMES= WITH 1-303D TYPE 1204 EPDXY OR /6 SELF TAPPING MACHINE SCREWS. 1/8 IN. POP RiVas in EN SUBSTITUTED WITH /6 SELF TAPPING MACHINE SCREWS. PRINTS VALID FOR BUILDING D EPARTEEN? PURPOSES ONLY SERE SIOEID BY THE ENGINE= OVER HIS SEAL. REVISED AUG 73 DELETED 1 BEAM AWED HA::GfiR BEAD PART IOS.&MISC W I L L A R D SHUTTER CO. MIAMI FLORIDA - oAa 9/64.1[011011,1110 rwle„M'rw loam Os rws °°'"" " 'Y A<'° eLL 1■10 ALL 01111101111010 1 6 719 I of Dear Mr. Miller: ABIAH A. CHURCH 546 N.E. 97 STREET MIAMI SHORES. FLORIDA 33138 Kenneth Russell Miller 3139 Commodore Plaza Coconut Grove Miami, Florida 33133 May 16, 1974 Re: Lots 4 and 5, Section 4, Amended; PB 15, page 4, Public Records of Dade Count Florida The purpose of this letter is to authorize you to obtain from the Building Department, Village of Miami Shores, Dade County, Florida, the plans of my residence at 546 N. E. 97th Street, Miami Shores, Florida, which are on file with that department. If anything further is needed, please let me know. C ordially, AAC:11 Abiah A. Church • • JOHN G. BOLEN GENERAL CONTRACTOR 901 N. E. 79TH STREET MIAMI 38, FLORIDA 1