444 NE 96 St (5)Zarho e Associotes Inc. Roofing Laboratory Testing and Research Moisture and Up -Lift Testing RE.: TEST TO DETERMINE ROOF TILES ARE SECURED TO DECK AFTER 30 DAYS INSTALLATION - SOUTH FLORIDA BLDG. CODE 3401.10 Date: 11/ 17/ 94 Property address: 444 N.E. 96th. St., Miami Shores, Fl Owner: Walker Contractor: Obenour Roofing Permit #: 36856 City: Miami Shores Village Type of Tile: Gory flat tile Product Control #: 94- 0323.20 Roof Slope: 3/ 12 Sq.ft. area: 1,700 sq.ft. approx. Testing Equipment: Chatillon - DFIS 100 - Calibrated 9/ 7/ 93 The purpose of this quality control test is to confirm that there exists sufficient bonding by the mortar to the tile and underlayment in the tile system applied; it will be determined whether 75% of the tile bonds to be tested in three different roof areas, provides sufficient resistance to an arbitrary static uplift load applied on the tile. This procedure will satisfy the Building Code Compliance requirements set forth in Protocol PA 106 -94. Tiles have been tested on three different roof areas: field, perimeter and corner areas. Prior to testing, dimensions of these areas were determined and recorded according to Chapter 23 of South Florida Building Code. Tiles selected at random from the three different areas, were lifted by hand, in order to test for loose components. LOAD APPLICATION: An arbitrary Toad of 35 Ibf. has been applied to each tile, holding the Toad for 5 seconds. Test results are tabulated as follows: 2524 W. 3rd. Avenue, Hialeah, Florida 33010 1 -800- 664 -8954 (305)437 -2332 Fax (305 }437 -229e Metro -Dade County Certification No. 94- 0125.0E November 18, 1994 AREA # PULLS LOOSE TILES BROKEN/ CRACKED TILES ADHESIVE DELAM INATED FROM UNDERLAYMENT TILES DELAM INATED FROM ADHESIVE Field 25 none none none none Perimeter 24 none none none none Corners 16 none none none none Enclosed find a sketch of the test site roof, indicating field, perimeter and corner areas with dimensions, and also, location where pulls have been conducted. XX Truly yours, Encl. Sketch More than 75% of the tile bonds tested in each of the three areas, provided sufficient resistance to the arbitrary load applied. More than 25% of the tile bonds tested in each of the three areas, did not provide sufficient resistance to the arbitrary load applied. More than 10% of the components have been determined to be "loose" components. The static uplift quality control test for the property in question, complies with the Code requirements 3401.10 and Protocol PA 106 -94. ZARA AND ASSOCIATES, INC. RICARDO A. ARLES, P.E. PROPERTY LOCATED AT 444 N. E. 96TH. ST. , MIAMI SHORES, FL Field Perimeter 0 Corners FRONT EXISTING TILE 2ND. STORY • • Date 9 -/ 91Z Job Address 14 AVE ' '5; Tax Folio /1 32dci 0 (/ ---O5$6 Legal Description Owner / Lessee / Tenant Owner's Address ¥4" NE. ! S/ • Contracting Co. O/3 . Architect /Engineer A) /fr Bonding Company Mortgagor Ai/ft' Square Ft. J rr' S 5 O FICIAL NOTARY S"' SAN *RA D /1s .�y4 ; Notary as to fSSI gte J ; My Commis': 4 1. 1 • _.`:' P. MAR.12,1997 FEES: PERMIT 30. APPROVED: Zoning PERMIT APPLICATION FOR MIAMI SHORES VILLAGE 13, // 4).4-Ci4- RADON esident Address Address Address Address Estimated Cost(value Notar My Co NOTARY Master Permit # 360_576-, -- S Phone 75/9 .."" Qualifier ,T.4KC E1 .�) . ��`S6NOd/ SS# - - Phone 7J c ' � % State # (430(, Municipal #tx)00oGS(.C'( Competency # Ins.Co. vtEe Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANIC A( ROOFING) PAVING FENCE SIGN WORK DESCRIPTION TEAL .0,43 ,&6 T / 574 4",e_0 /- 30 5ol Coto,L- 44'01li r-Pd G(Q fi�'ooiuS f /1! y /— 9 r ( it1D675r) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I e na ed contractor to do the work stated. authorize the above-na �,� A Signature and /or Condo President gnature of Contractor or Owner - Builder Date: Date: OFFICIAL OTARY A S IA 7) OBEN wp , �,! I`'�' IC i k u�Ij7 s. er- Builder ** * * * * * * * * * * * * * * * ** C.C.F. Fire Buildin�V�l /r/ Electrical Mechanical Plumbing Engineering TOTAL DUE ,3o?: Other NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT. TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. ��`-30 STATE OF FLORIDA: COUNTY OF DADE: 94R44U966 1994 SEP 16 13:40 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: -47 56 /Z LOS ik9/J7i O/ZS -2, `164.44 4 E J <v S 2. Description of improvement: /,t)STO -G/ A-eu) ,C T/ Z Io0 F�,J6 o•✓ c !4-S7 / s 727,L(f . 3. Owner(s) name and address: A/,C. , /L-4 Gt). /f 4- Interest in property: D& 0) E� Name and address of fee simple titleholder: 4. Contractor's name and address: €7- -', lc .'Fe 9 2- rAlez ae- ,,, site/es 5. Surety:(Payment bond required by owner from contractor, if any) Name and addressr Amount of bond $ 6. Lender's name and address: yr - 4) A- STATE OF FLOR 1 HMO A, COUNTY OF DADE e on 7. Persons within the State of Florida designated by 0 by Section 713.13(1)(a)7., Florida Statutes, Name and address: 8. In addition to himself,.Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) 41)1 %64 h Signature of Owner Print Owners Name f)'1 Q _Po( I( WA Ik.t. Sworn to and subscribed before me this T 1 4- day of Notary Public Print Notary's Name My Commission Expires_ MY COMMISSION EXP. MAR. 121997 5 1 -1 -4 40g4 .f7'4,64 .f7'4,64 I kilLr " ?MU 11111= iw o r�3l c es g 4 f9 waidF RU ® y ,19 99-. A® , 9 ent5cm: .ibeaserved as provided RK,,9 uiDon' County Court3 p.c. 2 • Prepared by: .'U f- Address: 4670 (r4D,scrt1 -S' / //v ( 33oL ( 12301.62 2/93 Job Address: METRO -DADE UNIFORM BUILDING PERMIT SECTION II MORTAR OR ADHESIVE SET TILE SYSTEMS 1. General ctyci 96, sr fl Alnet The information provided in this Section is required to confirm Product Control Approval of the proposed tile system assembly; confirm compliance with the wind load requirements of Chapter 23 of the South Florida Building Code (SFBC); and confirm compliance with Sections 3403.5 and 3404 of the South Florida Building Code. 2. Documentation The following documents are required for submission with the Uniform Building Permit application: • Two (2) copies of the proposed tile system assembly's and associated roofing component's Product Control Approval(s). • One (1) copy of the tile system assembly and/or roofing component(s) manufacturer's published application instructions and literature. • All documents attached herein, filled out and completed in full. 3. Project Information Check one of the following: ❑ New Construction, Re -Roof Note: Mortar or adhesive set tile systems are not acceptable as recover applications. Contractor: oh6too),C. Process No. Mortar or Adhesive Set Tile Systems Page -1 Is the deck solid sheathed? (circle 'yes' or 'no') no Deck Type (check one of the following l: Nominal W' Plywood (for re -roof only) Nominal /," Plywood Wood Plank " Other (fill Other (fill in) Roof Pitch (fill in): a 12" Note: Mortar or adhesive set tile systems shall not be installed at a pitch greater than 7'/: ":12 ". Mortar or adhesive set tile applied at a pitch greater than 5 ":12" and less than or equal to 7 ":12" shall have the first three courses of tile nailed with not less than one nail per tile. As an alternate, the first three courses of tile may be applied in mortar over a single Layer of minimum 12 ga. wire mesh with square openings of not less than 3 4" which is mechanically attached to the sheathing with not less than one nail per 2 ft'. Circle 'ves' or 'no' for each of the following: Have you attached two copies of the tile system manufacturer's Product Control Approval for the proposed tile system? j no Have you attached a copy of the tile system assembly and/or roofing component(s) manufacturer's published, application instructions and other literature es no Is the proposed underlayment approved for use with this tile system assembly? es no Job Address: W1 dE- f6) ST Project Information (continuedl: If the proposed underlayment is self - adhered, have you complied with the venting requirements of Section 2913.3 (b), (c) and (d) of the South Florida Building Code? yes no Are all related accessories approved for use with this tile system assembly? no Are the proposed edge metal attachment fasteners in compliance with the requirements of the South Florida Building Code (minimum 12 ga. annular ring shank, corrossion reisistant nails)? no 4. The Tile System Assembly: The following information is required to confirm compliance with Subsections 3403.5(a) and (c) and Section 3404 of the South Florida Building Code. Contractor: (06640J/..., . f • Tile: �1� Tile Name: lr-1Go-( - � -if Qr°d color - i1 1roolK Manufacturer: A.1 au t.. l o I .tj Tile Material: ❑ Clay Concrete ❑ Other: 9(1-63 Product Control Approval Number: Mortar or Adhesive: Check one of the following which apply to the proposed tile securement for use with the proposed tile system assembly: Mortar or Adhesive Set Tile Systems Page - 2 fig- Mortar: Manufacturer: 4014, et Mixing Ratio: ❑ Adhesive: Type: Manufacturer: Process No. Tile Fasteners (for first three courses if roof pitch exceeds 5 ":12" and is less than or equal to 7 ":12 "): Check one of the following which apply to the proposed tile fasteners (for the first three courses) for use with the proposed tile system assembly: ❑ Minimum 12 ga. galvanized roofing nail: ❑ Other: Type: Length: ❑ N/A Underlayment: Length: All tiles shall be installed in compliance with the provisions set forth in the tile system assembly manufacturer's Product Control Approval and the minimum requirements set forth in Subsections 3403.5(c) and 3404.2 of the South Florida Building Code. Tile fasteners in the first three courses (if applicible) shall be of sufficient length to penetrate the sheathing a minimum of 1" or through the sheathing thickness a minimum of '4 whichever is less. The following information is required to confirm compliance with Section 3403.5(b) of the South Florida Building Code. • Job Audress: 7 Y �� % S [ Contractui: QP.nNOJti Process No. Underlayment (continued): Check all of the following which apply to the proposed underlayment for use with the proposed tile system assembly: ASTM #30 asphalt saturated felt with: Manufacturer: J A &leo ❑ ASTM #15 asphalt saturated felt with: Manufacturer: Mineral Surfaced Roll Roofing with: Manufacturer: TA•tCo ❑ Other: Type: Manufacturer: Underlavment Fasteners (if applicable): ❑ Other: Type: Length: Manufacturer: O 19" overlap O 6" overlap 5. O 4" overlap ..• oJevI & r O 19" overlap O 6" overlap O 4" overlap O 19" overlap O 6" overlap O 4" overlap ooe vie. . Check one of the following which apply to the proposed underlayment attachment: ❑ Minimum 12 ga. electro - galvanized roofing nail with minimum 32 ga. x l'4" tin cap: Length: I 1 �r{ " Manufacturer: Mortar or Adhesive Set Tile Systems Page - 3 Spacing (per tile system assembly Produ. t Control Approval): Field: " o.c. Laps: 31. " o.c. Related Accessories: Edge Metal (refer to Section 3408.2 of the South Florida Building Code): Type: to .J>r dell t. Dimensions: 2. 1C 2" Gauge or Thickness: a.0 -s Finish: lu Note: All edge metal shall be nailed on the flange and nailed or clipped at the face in compliance with the provisions set forth in Dade County Protocol PA 111, marked Appendix 'U' in the South Florida Building Code. Adhesives (check one of the following): ❑ Cold Adhesive: Type: Manufacturer: Ci( Flashing Cement: Type: Manufacturer: ()kJ- A5 6—stn s Iro (fitc -4. Job Address: ti-LN #t)e—/Go Adhesives (continued): Additional Notes: Note: Application of adhesives shall be in compliance with the Roofing Component Product Control Approval and the minimum requirements set forth in Subsection 3403.5(e)(4)(cc) of the South Florida Building Code. Ventilation System (check one or more of the following): The following information is required to confirm compliance with Subsection 3401.4(e) of the South Florida Building Code. ❑ Ridge: Type Size in ❑ Soffit: Type Size in Note: If underlayment is comprised of a self - adhered membrane, both soffit and ridge ventilation systems are required, unless a base sheet is applied as an anchor sheet below the self - adhered underlayment_ Note: The Tile System Assembly shall be installed in strict compliance with the application instructions enumerated in the Product Control Approval. A permit shall be issued for application of the specified Tile System Assembly only. Any change to the specified Tile System Assembly shall require submission of a revised SECTION II with a copy of SECTION I, noting the permit number issued. Contractor: 10�1 Process No. Mortar or Adhesive Set Tile Systems Page - 4 Job ,,,,,tress: (1-0 AE. p6 S i Deck: Thickness Underlayment: Ridge Venting: ( 3� — yo Underlaymenti L Fastener: Roof Pitch 12" FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE UP TILE SYSTEM ASSEMBLY. INSERT ANY ADDITIONAL LEADERS INDICATING ADDITIONAL ROOFING COMPONENTS NOT SHOWN ON THIS PAGE. ( Where Roofing Component not used in Tile System Assembly, fill in with "N /A ". ) II Head Lap Dimension: 3 " (minimum Y wafers otherwise :pacified in the ilk totem assembly Product Control Approval) Mortar /Adhesive: quistotEr L Tile: RO4,f? 60l• y Piet o f -/1 Tile Fastener. N f Edge Metal or K Fastener: r / f Bird Stop: ((ltwplicablr) Edge Metal 2ra 14! v or Gutter. Existing or Proposed Soffit Venting: DETAIL #1 Job Site Identification: • Contract.... (O/jt1) 4_. Mortar or Adhesive Set Tile Systems Page - 5 Process No. Job Address: `w `i 7 (0 s Contractor: Rd; Height: f eet Eav Height. Roof Mean"Hcight �n feet feet Insert Building Ridge Height, Eave Height and Roof Mean Height. Also insert applicable information pertaining to the building below. (See ASCE 7-88 Fact Sheet Arched ) Exposure Category: ( j Classification Category: At Hurricance Oceanline ?: _ Y N Basic Wind Speed at Building Location: 110 mph Building Condition based on % of openings: (See Table 9 ofASCE 7-88) Ground Level q /r BUILDING INFORMATION #1 .rA Job Site Identification: Z� add / seat Mortar or Adhesive Set Tile Systems Page - 6 gaZd Process No. V(f‘i toe- f sr Job ,,adress: Contratwr: Mortar or Adhesive Set Tile Systems Page - 7 Process No. 2 s ?d # N &JD ae Sketch Roof Plan, indicating all dimensions, slopes and any roof top equipment Also insert variable labeled "a" which represents perimeter and comer dimensions per Chapter 23 of the South Florida Building Code. (See ASCE 7 -88 Fact Sheet Attached) fik (d ?2.3 PC // , “ 4,kbe lZ /r 0 aim rs BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimen 'ons Job Site Identification: (S7/ y e r Job Address: W5 di - l ' S' Contractor: aced The undersigned certifies that the Mortar or Adhesive Set Tile System Assembly is in compliance with the plans, specifications, and details submitted by the architect. STATE OF FLORIDA - COUNTY OF DADE Before me this day personally appeared `%/W!S !' a‘••40(.1, who, being first duly sworn, deposes and says that all information submitted herein is true and correct. Sworn to and subscribed before me this . th da of 19 qL. My commission expires: Licensed Contractor / Owner Signature OM !� .OTARa 2 SAMOA D Of„NOUR NCYFARY FOLIC ° Os 71.ORIDA c'fVT✓tKJr(... - CC.265272 MY COMMLSS , LL ' \R. 121997 Q CAprci J/a. 1) Q AuDej7c., Notary Public State of Florida Mortar or Adhesive Set Tile Systems Page - 8 Process No. • ' ME+�A 3E METROPOLITAN DADE COUNTY, FLORIDA MiN METRO -DADE FLAGLER BUILDING Monier Roof Tile 1900 NW 21st Avenue Fort Lauderdale, FL 33311 Your application for Product Approval of the Bermuda Flat tile profile under Chapter 8 of the Metropolitan Dade County Code governing use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted has been recommended for acceptance by the Building Code Compliance Department to be used in Dade County, Florida under the Standard Conditions attached provided the tile systems are approved in strict compliance with Protocols PA 118, 119, 120. This approval supersedes all sections of previous tile approvals which reference Chapter 34, Appendix X, Systems 1 -3. Appendix X has been redesignated PA 118, 119 and 120of the South Florida Building Code. This approval shall remain valid until implementation of the 1994 revision of the South Florida Building Code. The Building Code Compliance Department reserves the right to secure a product or material at any time from a job site or manufacturing plant for quality control testing. If product or material fail to perform in the approved manner, the Code Compliance Department may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Department reserves the right to require retesting of this product should any amendments to the South Florida Building Code be enacted affecting this product. The expense of such testing shall be incurred by the manufacturer. Product No.: Acceptance No.: 94- 0323.20 - PLEASE NOTE- THIS JS THE COVER SHEET. SEE ADDITIONAL ORIGINAL APPROVAL FOR SPECIFIC AND GENERAL CONDITIONS, BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Approved 1't4A 2 4 1994 BUILDING CODE COMPLIANCE DEPARTMENT SUITE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375-2901 PRODUCT CONTROL NOTICE OF ACCEPTANCE, FAX (305) 375 -2908 Gil Diamond, P.E. Product Control Division Supervisor (1 4 7 Charles Danger, P.E., Directo Building Code Compliance Department Metropolitan Dade County Product Detail Product Control No.: 94- 0323.20 T3Fau 22. FLAT SHINGLE TILE /VA N G.uA.e.o Tti-E Construction Research #5749 Laboratory, Inc. Test Agency • Test Identifier J.E. Brennan Consulting Engineers, Inc. J.E. Brennan, Consulting Engineers, Inc. Ned Shah, P.E. Professional Service Industries, Inc., Jammall & Associates Division Test Reports #5750 #5613 Gory- VR00130 -SPU JEBCE1- 097 - 001 -90 Engineering Report #224 - 17017 Product Control No.: 94- 0323.20 Test Name/Report Date Infiltration Resistance 03/05/93 Infiltration Resistance 03/05/93 Infiltration Resistance 04/01/92 Material Properties Test 04/30/90 Material Properties Test 04 /30/90 Uplift Approvals 05/04/91 Uplift Approvals 05/01/91 Note: Test #5613 is applicable to all National Tile Roofing Manufacturer's Association members. Please see the March 18, 1994 letter, attached. 0 March 18, 1994 Mr. Rick Olson National Tile Roofing Manufacturer's Association, Inc. Post Office Box 40337 Eugene, Oregon 97404 -0049 Reference: L,i feti sill, Dear Rick: Further to our telephone conversation, please accept this Lotter as Boral Concrete Product's authot'ixation for the NTRMA to use test data developed by this company relating to the mortar set system. Please do not hesitate to call me if you require any further informations. Yours sincerely, Eric Moycs V President EM:dw SIM 5O Co NO PI SSTIS PRO TS XANDMA1L P.1 A Division of BOW, Industries Imo North Raven Avenue Suite 240 Ontario, California 01784 Telephone: 909/9444700 Fax: 909/948 -1482 r .ham ,,�. 5( \\ RUBEROID® Specification N- 1 -1 -MG 2' Mln. Side Lap Max. GAFGLAS 175 Base Sheet RUSER010 MOP '/i Min. Nailable Deck Steep Asphalt ASTM Type III or IV Substrate —y, inch minimum plywood, gypsum, structural wood fiber, lightweight insulating concrete. See "Lightweight Insulating Concrete Decks," page 10. Slope —Up to 1 inch per foot for lightweight insulating concrete; up to 3 inches per foot foFother decks. Materials GAF Materials Corporation Steep Roofing Asphalt ASTM 0 -312 Type III or IV GAFGLAS #75 Base Sheet RUBEROID MOP (Granule Surfaced) Approximate Weight Per Square Total 145 -155 lbs. Guarantees Available Specification RUBEROID Liberty RUBEROID N - 1 - - 12,10 12,10 GAF KAMM*, CORPORATIC General Recommendations presented on pages 17 -22 shall apply in addition to the following application recommendations. Application Recommendations 1. Lay one ply of GAFGLAS® #75 Base Sheet (or in the case of a fresh Iightweigi insulating concrete or gypsum deck where STRATAVENP (Vent Pty) for Nailabl: Decks is required), with a minimum 2 inch side lap and not less than 6 inch end laps. Nail along side lap of the base ply at intervals not to exceed 9 inches and stagger -nail down the center of sheet in two rows with nails spaced at 18 inch intervals in each row. 2. Starting at the low point of the roof, fully embed one ply of RUBEROID MOP (Granule) in a nominal 25 pounds per 100 square feet (plus or minus 20 %) continuous coat of Steep Roofing Asphalt ASTM D -312 Type III or IV. The RUBEROID membrane must be positioned to provide 4 inch side laps and 6 inch end laps. 51 •;- " )c7 • ( 7 , / • 4 GAF Building Materials Corporation (MB) 1361 Alps Road Wayne, NJ 07470 Your application for Product Approval of GAF Ruberoid Roofing Systems under Chapter 8 of Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by GAF Building Materials Corporation, Factory Mutual Research Corporation, Underwriters Laboratories, South Florida Test Sevice, and Construction Research Laboratories has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the Specific Conditions set forth in pages 2 et seq. and in the Standard Conditions detailed on page 3. The approval shall be valid for a period of three years. The Office of Code Compliance reserves the right to require retesting of this system within the first two years of the approval should any amendments to the South Florida Building Code be enacted affecting th o . ent o roof system. /' ACCEPTANCE No: 93- 1130.04 EXPIRES: DEC 13 1996 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. APPROVED: .DEC 1 3 1993 PRODUCT CONTROL NOTICE OF ACCEPTANCE * *PLEASE NOTE ** / 1 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 1 Diamond, P.E. roduct Control Division Supervisor Charles Danger Building Code Compliance Department Metropolitan Dade County METRO -DADE • Revised 9 -20 -93 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 NOTICE OF ACCEPTANCE: STANDARD CONDITIONS 1. Extension of Acceptance may be considered after a new application has been filed and the supporting data, test report no older than ten (10) years, have been re- evaluated. All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of Florida. 2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically be cause for termination, unless prior approval is granted for revisions or change. 3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds for re- evaluation. 4. This acceptance shall not be used as an endorsement of any product for sales or advertising purposes. 5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 6. A copy of this approval as well as approved drawings and other documents, where it applies, shall be provided to the applicant by the manufacturer or his distributors and shall be available for inspection at the job site at all time. The prints need not be re- sealed by the engineer. 7. Failure to comply with Standard Conditions shall be cause for termination of Approval. 3 1 Diamond, P.E. Supervisor Product Control Division J Manufacturer: Contact: Trade Names of Products Manufactured by Applicant: Ruberoid® Torch Plus — Ruberoid® Torch FR 1VLL 1KU-Ltkl)L 1) ULLL11`I j I. VLL' t.VIVU'Lit11V PRODUCT APPROVAL SECTION ROOF SYSTEM APPROVAL GAF Building Materials Corporation (MB) 1361 Alps Road Wayne, NJ 07470 Product Control No.: 93- 1130.04 • System: Membrane Roofing System Subsystem: BUR Type: Modified Bitumen Roofing System Type: APP, SBS William J. Woodring Director of Technical Services (201) 628 -3000 Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: DEC 13 1996 Ruberoid® Torch Plus is a modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Torch Plus is surfaced with granules and applied by torch. Roll weight: 93 lbs.; Roll Size: 75 ft. Dimensions: 39.4" x 22.8'. Ruberoid Torch FR is a fire retarding modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid Torch FR is surfaced with mineral granules and applied by torch. Roll weight: 90 lbs.; Roll Size: 75 ft.2; Trade Names of Products Manufactured by Applicant: Ruberoid® Torch Smooth • Ruberoid® Mop Plus Ruberoid® Mop FR Ruberoid® Mop Smooth Ruberoid® 20 (FR) 3 Acceptance Number: 93- 1130.04 Approved: . DEC 1 3 1993 Expires: QEC 13 1996 Dimensions: 39.4" x 22.8'. Ruberoid® Torch Smooth is a modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Torch Smooth is smooth surfaced and applied by torch. Roll weight: 87 lbs.; Roll size: 100 ft. • Dimensions: 39.4" x 30.5'. Ruberoid® Mop Plus is a 'Heavy Duty' modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Mop Plus is surfaced with granules and applied in hot asphalt Roll weight: 98 lbs.; Roll Size: 75 ft. Dimensions: 39.4" x 22.8'. Ruberoid® Mop FR is a fire retarding modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Mop FR is surfaced with mineral granules and applied in hot asphalt. Roll weight: 110 lbs.; Roll Size: 75 ft. Dimensions: 39.4" x 22.8'. Ruberoid® Mop Smooth is a modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Mop Smooth is smooth surfaced and applied in hot asphalt Roll weight: 88 lbs.; Roll size: 100 ft. Dimensions: 39.4" x 30.5'. Ruberoid® 20 (FR) is the bottom ply of a two ply system also consisting of Ruberoid® 30 (FR) as the top ply. .J • Trade Names of Products Manufactured by Applicant: Gafglas® Ply 6® Gafglas® Ply 4 Gafglas® Stratavent® Perforated Gafglas® #75 Ruberoid® Torch Granule Acceptance Number: 93- 1130.04 Approved: I.DFC 1 3 1993 Expires:. DEC 1 3 1996 Ruberoid® 20 FR is a fire retardant polymer SBS modified bitumen. Roll weight: 95 lbs.; Dimensions: 39.4 x 45.5'; Roll size: 150 ft. Gafglas® Ply 6® is an asphalt coated roofing felt with a glass fiber mat. Roll weight: 441bs.; Roll size: 500 ft. Dimensions: 3' x 166 ". Gafglas® Ply 4 is an asphalt coated roofing felt with a glass fiber mat. Roll weight: 40 lbs.; Roll size: 500 ft. Dimensions: 3' x 166'. Gafglas® Stratavent® Perforated is an asphalt coated base sheet with a glass fiber mat. The bottom side of Gaflas® Stratavent® Perforated is surfaced with granules. Gafglas® Stratavent® Perforated has 5/8" diameter perforations cut 3" o.c. and is for use over nailable decks. Roll weight: 60 lbs.; Dimensions: 3' x 36'. Gafglas® #75 is an asphalt coated base sheet with a glass fiber mat. Roll weight: 75 lbs.; Dimensions: 3' x 108'. Ruberoid® Torch Granule is a modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Torch Granule is surfaced with mineral granules and applied by torch. Roll weight: 102 lbs.; Roll size: 100 ft. Dimensions: 39.4" x 30.5'. f Trade Names of Products Manufactured by Applicant: Ruberoid® Mop Granule . Ruberoid® 30 (FR) Gafglas® Stratavent® GAF Weather Coat® GAF Weather Coat® Emulsion is a Emulsion surface coating for smooth - suraced roofs. Coverage: 2.5 gallons/square.; Packing: 5 gallon pails. GAF Fibered Aluminum Coating GAF JetblakTM Flashtite® Cement used for flashing and eave construction. Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: LLEC 13 1996 Ruberoid® Mop Granule is a modified bitumen membrane with a polymer asphalt coated polyester mat. Ruberoid® Mop Granule is surfaced with mineral granules and applied in hot asphalt. Roll weight: 103 lbs.; Roll size: 100 ft. Dimensions: 39.4" x 30.5'. Ruberoid® 30 (FR) is the top ply of a two ply system also consisting of Ruberoid® 20 (FR) as the bottom ply. Ruberoid® 30 (FR) is a fire retardant polymer SBS modified bitumen and surfaced with granules. Roll weight: 92 lbs.; Dimensions: 39.4" x 30.5'; Roll size: 100 ft. Gafglas® Stratavent® is an asphalt coated base sheet with a glass fiber mat. The bottom side of Gaflas® Stratavent® is surfaced with granules. Roll weight: 69 lbs.; Dimensions: 3' x 36'. GAF Fibered Aluminum Coating is used to protect smooth - surfaced composition roofs,metal, and masonry. Coverage: 2 gallons/square; Packing: 1 and 5 gallon pails. GAF JetblakTM Flashtite® Cement is l it Diamond, P.E. . • • Trade Names of Products Manufactured by Applicant: GAF Plastic Cement GAF JetblakTM All- Weather Plastic Cement GAF Asphalt/Concrete Primer GAF Mineral Shield® Granules GAF Gaftite Roof Insulation Fasteners Vent Stacks, metal and plastic Acceptance Number: 93- 1130.04 Approved: ,DEC 1 3 1993 Expires: ► DEC 1 3 1996 Coverage: 75 lbs. /square; Packing: 1 and 5 gallon pails, 53 gallon drums. GAF Plastic Cement is used for installing flashing material. Coverage: 75 lbs./square; Packing: 1 and.5 gallon pails, 53 gallon drums. GAF JetblakTM All- Weather Plastic Cement is used to install flashing and may be applied on wet surfaces. Coverage: 1 gallon/14 ft.'; Packing: 1 and 5 gallon pails. GAF Asphalt/Concrete Primer used to promote adhesion of asphalt in built -up roofing. Coverage: 1 -2 gallons/square; Packing: 5 gallon pails, 53 gallon drums. Granules for surfacing of exposed asphalt, cold process or emulsion. Packing: 60 lb. bags. Various fasteners for use over steel, heavy steel, plywood, structural concrete, cementitious wood fiber, gypsum, and lightweight concrete decks. GAF Vent Stacks are one way valve systems used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. if Diamond, P.E. Trade Names of Products Manufactured by Others: Company /Applicant GAF Building Materials Corporation (MB) Product Name Insulfixx Fastening Systems Dekfast Fastening Assemblies Roofgrip, Gripdek Olympic, Contite Rawl Spike® New Striker, Tapcon Dekfast #14 & #15 Pneutek CDIF ASTM D-41 Primer ASTM D -312 roofing asphalt Rawl Deck Screw Rawl Loop Toggle Rawl Rawlite® PRODUCT APPROVAL SECTION Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: 1 3 1996 Product Description Steel & Concrete Insulation Fastening Assembly Steel & Concrete Insulation Fastening Assembly Steel & Concrete Insulation Fastening Assembly Steel & Concrete Insulation Fastening Assembly Concrete Insulation Fastening Assembly Insulation Fastening Assembly Insulation Fastening Assembly Insulation Fastening Assembly Asphalt Primer Bonding Asphalt Steel & Concrete Insulation Fastening Assembly Lightweight Concrete Insulation Fastening Assembly Lightweight Concrete Insulation Fastening Assembly (See FM listings for approved insulation fasteners with specific insulation panels.) Gil Diamond, P.E Manufacturer SFS/Fabco Construction Fasteners, Inc. ITWBuildex Olympic The Rawlplug Company ITWBuildex ITW/Buildex Pneutek Generic Generic The Rawlplug Company The Rawlplug Company The Rawlplug Company Trade Names of Products . Manufactured by Others: Company /Applicant Product Name Es Products FM -90, FM-60, FM-45, FM -30 Karnak No. 97 & No. 169 AL MB Aluminum Roof Coating Karnak No. 81 Gibson -Homan No. 6160 Grundy 20 F Emulsion Nails Tin Caps CR -Base Sheet Plate CR -Base Sheet Fastener CR -1.2 Base Sheet Fastener Nail -Tite® Type A Nail -Tite® Type R Approved: ,DEC 1 3 1993 Expires:IOEC 1 1996 Product Description Base Ply Fasteners Roof Coating Roof Coating Cold Applied Adhesive Cold Applied Adhesive Roof Coating Min. diameter #12 corrosion resistant annular ring shank nails, FF -N- 105 -B, Type 2 Min. 32 ga. x 1 5/8" corrosion resistant circular discs 2.75" galvalume steel stress plate CR -10 coated galvanized steel fastener. Head size: 1.125" x 1 "; Length: 1.2" CR -10 coated galvanized steel fastener. Head size: 1.125" x 1 "; Length: 1.2" Galvanized steel Base Ply Fastener (Lightweight Insulating Concrete only) Galvanized steel Base Ply Fastener (Lightweight Insulating Concrete only) (See FM listings for approved insulation fasteners with specific insulation panels.) Gil Diamond, P. Manufacturer ES Products Karnak Chemical Corporation Grundy Industries Karnak Chemical Corporation Gibson -Homan Grundy Industries Generic Generic Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. Olympic Manufacturing Group, Inc. ES Products, Inc. ES Products, Inc. Trade Names of Products Manufactured by Others: Company /Applicant Product Name Product Description Manufacturer FM -30 Disc Red Rosin Rosin paper for barrier layer Generic on wood decks Disc for ES Products FM-45 and FM-60 Base Ply Fasteners (See FM listings for approved insulation fasteners with specific insulation panels.) prd LOEC 1 3 19 93 Expires: Apove L&C 1133 3 1996 Gil Diamond, P.E. ES Products, Inc. System Description: Acceptance Number: 93- 1130.04 Approved: ;DEC 1, 3 1993 Expires:. DEC 1 3 1995 GAF Bulilding Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up and modified bitumen roofing systems. The modified bitumen products include both APP (Atactic Polypropylene) and SBS (Styrene Butadien Styrene) products in smooth, granule and fire rated versions. In addition GAF offers two ply modified systems to meet the specifications requirements for multilayer SBS modified specificatons. GAF products are distributed through a wide network of roofing wholesale distributors thoughout the South Florida area. The Technical Service Office is located in Wayne, New Jersey and can be contacted at 1- 800 - ROOF -411. GAF provides warranted sytstems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and Specification manual published annually. The GAF Roof System Assemblies gave been extensively tested at Factory Mutual Research Corporation and Updrewriters Laboratories. Five classifications for assemblies are listed in the current U.L. Roofing Material Directory and the current Factory Mutual Approval Guide. GAF Modified Bitumen membranes have been tested in compliance with ASTM D -5147 test requirment. Test data is on file. The following documents were submitted with the application: 1993 Sweets Catalog Introducing Ruberoid 20/30 FR Information Sheets and Brochures: GAFGLAS® Built -Up Roofing Applications and Specifications, 1993 GAFGLAS® Ruberoid Modified Bitumen Roofing Application and Specifications, 1993 Commercial Roofing Systems and Products, 1993 GAFGLAS® Stratavent Base Sheets GC10043 (5/92) GAFGLAS Mineral Surfaced Cap Sheet GC10042 (5/92) GAFGLAS Flashing GC10044 (5/92) GAFGLAS #75 Base Sheet Gc10041 (5/92) GAFGLAS Ply 4 GC10040 (5/92) GAFGLAS Ply 6 GC10039 (5/92) RUBEROID® Torch Plus GC10040 (5/92) RUBEROID Torch FR GC10039 (5/92) RUBEROID Torch GC 10122 (5/92) RUBEROID Mop GC10113 (5/92) RUBEROID Mop Plus GC10116 (5/92) RUBEROID Mop FR GC10119 (5/92) Introducing RUBEROID 20/30 FR GC10137 (1/92 -1) RUBEROID 20/30 FR GC10134 (5/92) 1D Gil. Diamond P. Cements and Coatings 2223-308R3 GAF Vent Stacks (1990) 1 ' Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: [DEC 1 3 1996 • • Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: !OE 1 3 1996 Company /Applicant GAF Building Materials Corporation (MB) TESTING Company Performing Test Construction Research Laboratories Canadian General Standards Board South Florida Test Service Factory Mutual Research . Corporation I2 Test Name/Report # 4818 37- GP -56M GAF -53 -X -915 J.I. 0Q6A6.AM J.I.0T2Q4.AM J.I. OT4A1.AM J.I. 1R1A6.AM J.I. 1V7AO.AM J.I. 1 V8A4. AM J.I. 2M0A4.AM • Date 07/10/87 01/07/80 03/08/91 07/16/91 10/17/91 08/26/92 11/15/91 07/16/92 06/28/93 03/21/87 Company /Applicant TESTING Company Performing Test Underwriters Laboratories, Inc. / 3 Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: DEC 13 1996 Test Name/Report Date R1306, see current directory 01/01/93 R1306/87NK11819, 87NK496 12/07/87 Gil Diamond, Approved: i DEC 1 3 1993 Expires:. DEC 1 3 1996 System Number Deck Deck description 1 (SBS) Acceptance Number: 93- 1130.04 Steel/Wood 18 - 22 ga. steel deck, wood plank or min. 5/8" plywood. New construction and reroofing. For steel decks less than 22 ga. but not less than 26 ga. TPR fastener and Olympic 3" round or SFS type 'S' stress plate may be utilized at a density of 1:2 ft. Field fastener testing is required on all re -roof projects to confirm a minimum withdrawal resistance of 400 lbs.. Systems installed over steel deck less than 22 ga. require written approval from GAF Technical Department. Vapor Retarder (Optional) (Optional) Insulation (Optional for wood decks only) (Steel decks only) Any Factory Mutual approved vapor retarder with proprietary or approved adhesive or such other vapor retarder system designed by the architect or design engineer. The vapor retarder forms part of the roof assembly for fire classification. See Factory Mutual Approval Guide for listings. First ply shall not be bonded to wood decks. A red rosin sheet may be applied below the base sheet over wood and plywood decks. Wood fiber; fiberglass; perlite; polyisocyanurate; perlitefisocyanurate composite; basalt rockwool, or gypsum board: Insulation shall be either bonded to a nailed base sheet (see base sheet nailing pattern) in a full mopping of ASTM D -312, type III or type IV hot asphalt or mechanically attached with a Factory Mutual approved fastening assembly listed with the insulation panel. (See Approved Insulations and Fastening Patterns List). Moisture content in an existing built -up roof must be in compliance with Section 3401.9(c) of the South Florida Building Code. Prior to application, all existing roof surfaces used as a bonding substrate shall 3 2 Gil Diamond, P. Note: No insulation panels shall be bonded to an existing built up roof with a gravel surface without full removal of the loose gravel, priming of the surface with ASTM D-41 primer, and a flood coat of asphalt, prior to mopping of the insulation with bonding asphalt. Refer to GAF published application considerations for insulation application and to attachment requirements published in the current Factory Mutual Approval Guide. Basesheet Option #1: Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: DEC 13 1996 be tested for uplift resistance in compliance with ASTM E -907 to the calculated design velocity pressure of the roof deck. Existing roof surfaces and dissimilar materials must be fully primed with ASTM D-41 primer and allowed to dry. If insulation board is bonded to the existing roof or to a base sheet no one dimension should be greater than 4 ft. If more than one insulation layer is applied, the top layer may be mechanically attached or bonded in a full mopping of ASTM D -312, type III or type IV asphalt. One ply of Gafglas #75, Gafglas Stratavent (non perforated), Gafgas Ply 4, Gafglas Ply 6, Ruberoid 20 or Ruberoid 20 FR mechanically attached to the wood deck with approved nails and tin caps 9" o.c. at the laps and 18" o.c. staggered in two rows in the field, or over an insulation substrate with insulation fastener and plate assemblies 18" o.c. at the laps and 36" o.c. staggered in two rows in the field. (See Comments and Limitations #6 and #7) Option #2: One ply of Gafglas #75, Gafglas Ply 4, Gafglas Ply 6, Gafglas non - perforated Stratavent, Ruberoid 20 or Ruberoid 20 FR bonded to an insulated substrate attached with Factory Mutual approved fastening assemblies in compliance with FM class 1 -90 windstorm classification requirements, in a solid mopping or mopped in ribbons maintaining 50% adhesion, using type III or type IV hot asphalt at a 3� rate of 25 lbs. per square ±20% or Gafglas perforated Stratavent applied dry to the insulated substrate and mopped over with a full mopping of type III or type IV asphalt over which an interply of Ply 4 or Ply 6 shall be applied. (See Comments and Limitations #8 and #9) Plysheet (Optional) Acceptance Number: 93- 1130.04 Approved: ,DEC 1 3 1993 Expires: DEC 1 3 1996 Mop one or two plys of Gafglas Ply 4, Gafglas Ply 6, Ruberoid 20 . (FR), or Ruberoid Mop in ASTM D -312 type III or IV at a rate of 25 pounds per square ± 20 %. Membrane Mop one of the following membranes in a solid mopping of ASTM . D -312, type III or IV asphalt at a rate of 25 pounds per square ± 20 %: Surfacing Ruberoid Mop Ruberoid Mop Plus Ruberoid Mop FR Ruberoid 30 Ruberoid 30 FR The base sheet and the cap sheet shall maintain a minimum stagger of 12 inches for all laps. (See GAF application instructions) Option #1: Apply not less than 400 pounds per square of ASTM D -1863 aggregate or 300 per square of slag in a pour coat of an ASTM D -312 type III or type IV asphalt. Comply with GAF slope requirements for slope and type of asphalt. Gravel surfacing shall be completed as soon as practical but the membrane shall not remain exposed for more than 30 days. Option #2: Apply one of the following roof coatings at the specified rate: 3 L ( roof coating rate GAF WEATHER COAT Emulsion GAF Grundy Fibered Aluminum Coating Karnak No. 97 Gil Diamond, P. 3 gals. /sq. 11/2 gals. /sq. 11/2-3 gals. /sq. Acceptance Number: 93- 1130.04 • Approved: DEC 1 3 1993 Expires: DEC 13 1996 Flashings Refer to GAF application instructions for flashing specifications. Fastening Install all plies of Gafglas Felts used in conjunction with all Ruberoid membranes vertically on slopes of 1 inch per foot or more and backnail them into wood nailers or nailable decks approximately 4 inches from the back edge of the sheet. All end laps must be at wood nailers, and the top edge must nailed into the wood nailer on 6" centers. Use approved roofing nails and tin caps. Comment and Limitations Karnak No. 169 1'h -3 gals. /sq. Grundy Industries 20 F Emulsion 3 gals. /sq. Grundy AL MB Aluminum Roof Coating 1 -2 gals. /sq. Note slope limitations and membrane aging requirements published by GAF. The Ruberoid membranes shall be terminated at nailers as dictated above. For non - insulated wood decks, terminate and nail the end of Ruberoid membrane on the same nailer spacings indicated above. The membrane must then be nailed off on 6" centers, 2" from the top of the membrane, into the nailer or wood deck using nails with integral metal heads at least 1" round or square. The overlapping membrane must extend at least 6" past the center line of these nails. See Approved Insulation and Fastening Pattern list attached. 1. Maximum slope shall be 6 ":12 ". (Any application over 1 " :12 ", shall require backnailing of all plies 4" in from the back edge of the felts into wood nailers.) 2. An overlay insulation panel is required on all applications over closed cell insulations (See Insulation List). 3. All perimeter nailer and metal profile design shall conform with Factory Mutual Loss Prevention Data Sheet 1-49. 4. All asphalt shall comply with ASTM D -312 requirements. 5. Bonding to dissimilar surfaces (other than insulation facers and asphalt saturated membranes) should be be preceded by an application of ASTM D-41 primer for asphalt applications and allowed to fully dry. 6. This roof system assembly, when applied over a steel deck and mechanically attached at 18" in the lap and two rows at 36" in the 3C Gil Diamond, P.E. Acceptance Number: 93- 1130.04 Approved: DEC 1 3 1993 Expires: LOEC 1 3 1996 field with min. 3" diameter FM approved fastener plates has been approved for use to a maximum field design velocity pressure of -45 psf 7. This roof system assembly, when applied over a wood plank deck with an ASTM D -2626 or D-4601 base sheet mechanically attached at 9" in the lap and two rows at 18" in the field with min. 12 ga. annular ring shank nails and min. 1 5/8" tin caps has been approved for use to a maximum field design velocity pressure of -45 psf. 8. This roof system assembly, when bonded to an insulation substrate has been approved for use to a maximum field design velocity pressure of -45 psf. 9. This roof assembly, when applied over a perforated Stratavent base sheet in an intermittent mopping of asphalt is approved for use over a non nailable or insulated substrate to a maximum design velocity pressure of -30 psf. 10. Perimeter and corner areas shall have an increase in fastener density for both insulation and base sheet in compliance with the Factory Mutual Loss Prevention Data sheets 1 -28 and 1 -28S. 11. The chosen assembly must comply with the fire resistance requirements of Sections 3401.5 and 3401.6 of the South Florida Building Code. Refer to fire 'classification ratings' in the Underwriters Laboratories Current Directory. 12. Any amendments to these provisions shall be in compliance with Section 203 and 204 of the South Florida Building Code. 13. Refer to GAF specifications for appropriate flashing materials. 14. Refer to one of the following GAF specifications for this application:- I- 1 -1 -MG, I -1 -1 -MSC, I -2 -1 -MGP, I- 2- 1- MGPFR, I -3 -1 -MGP, I -3 -1- MGPFR, I -0-2 -MGP, I -0-2- MGPFR, I -1 -2 -MGP, I- 1- 2- MGPFR, I -0-2- 20/30, I -0- 2- 20/30FR, I- 1- 2- 20/30, I- 1- 2- 20 /30FR, I- 1- 2- 20/MG, I- 1- 2- 20/MGP, I- 1- 2- 20/MGPFR, • N- 1 -1 -MG, N -1 -1 -MSC, N- 1- 2- 20/30, and N- 1- 2- 20/30FR 15. A withdrawal resistance test shall be carried out on all reroof and recover projects to confirm deck integrity. 16. Walkways may be fabricated from one ply of Ruberoid Mop Plus or Torch Plus (Granule) fully bonded to the top membrane ply. Gil Diamond, P.E. Name and address of licensed contractor APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village. Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with. whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date June 12 ,1989 19 Owner's Name and Address Mrs W.H. WALTER No . 444 N. E.street 96th Registered Architect and/or Engineer Pan Am Roofing Co.Inc. Location and legal description of lot to be built on: Q p _J� Lo 'd LI Block 9 Subdivision 70 C/ Street and Number where work is to be done State work to be done and purpose of building (by floors), state exterior colors (submit samples) Re -Ed of flat section only • . Remove roof down to wood sheathing.Replace all rotted uood.Tin cap 1/43 saturated felt. Apply' 2/15 lb. felts and install gravel. (6-4 and for no other purpose. New Building Remodeling Addition Repairs No of Stories To be constructed of Kind of foundation °� Roof Covering Estimated T fa, cost of improvements S I �t�' !/0 Amount of Permit S a' o' Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor 1 hereby submit all plans and specifications for said building. All notices with reference to the building and its construction may be sent to Pan Am Roofing Co.Inc. 1360 N.W. 29th St :- Miami,FL 33142 The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligatons as an employer of Labor under the Florida Workmen's Compensation Act, being Section 5966. Compiled General Laws of Florida. Permanent Supplement. and has complied with the provisions thereof. and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under his permi : and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agre s to loy my such subcon)sacL, rs. on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA COUNTY OF DADE. }ss. Before me. the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments. personally appeared to me well known. and who. being by me first duly sworn, upon oath deposes and says that he is the of the above described construction. that he has carefully read the foregoing application, and that he did sign the same. and that all facts therein by him stated are true. Permit No. 1/ Disapproved T Date (Signed) Building Inspector PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved 1 ate Disapproved Date NOTE: A charge of $25.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $25.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT Date ‘//g/g7 Read, Sworn to and Subscribed before me. I/ JAD6 /y i - g o 444 N.E. 96th Street Miami Shores, FL Ruben Bernal (Roofi Notary Public. State of Florida My Commission Expires MIAMI SHORC S//ILLAGE BUILDING INSPECTFbN /DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address .W r 1\ ..4 Registered Architect and /or l;ngincer Name and address of licensed contractor.. Location d legal description of lot to be built on: Lot 1-- q ( O Block 4. 3 Subdivision Street and Number where work is to be done a 1 N - � State work to be done nd purpose of , t g (by floors) (Sign ,u 1 Date ..._ _.� .1 .._._ _..._.... ,19 L :.. �I.- . . Street�Q.. a. §_lvj. Cq and for no other purpose. New Building Remodeling V Addition Repairs No. of Stories To be constructed of and of found C overing Estimated Total cost of improvements ' ..�1 Amount of Permit S. .h Zone required a uired plan Cubage a Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ o_such s n. ctors o work to be performed under this pcnnit, as are licensed by Miami Shores Village. Remarks. STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared — - to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No._.__.___i (467 Date `� Read, Swo • to and Subscribed before me. Disapproved _ .. Date Notary Public, State of Florida (Signed) [N s Bui .in spector My Commission Expires PLANNI ' • BOARD DATE Chairman Member Member Member Member ...... _....-- •- -- .._..--- _.. - - -_ Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning hoard. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Owner's Name and Address Location and legal description of lot to be built on: Lot Block MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT. APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build - ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. tk, tHL Registered Architect and /or Engineer ................ .. .11..1 . 121 222 ., -.1 Name and address of licensed contractor i' t R OOP DOCT INC. / /02' / 7f 6P. ? OLL L2 0e `24 . YIP/ q Street and Number where work is to be done P / ( — 1 ST. State work to be done and purpose of building (by floors) ( ‘/Z- ci3F /A ( ti r I}G zS /0. Q, Fr. OP F'.M1 Colour 7746 c /TN _.. b oo a S 'Q . FT. or 71 '.eA - ✓EZ urn/ New Building Remodeling Addition To be constructed of Kind of foundation Estimated Total cost of improvements $ 38OO e� Amount of Permit $. Zone cubage required .Plan Cubage Distance to 'next nearest building Size of Building Lot Disapproved Date. (Signed) No............_...... Street...._ � K 6 3 /1. !'rcer f ?4 T C-r1ritir 77 y.rlii Ves " and for no other purpose. Repairs No. of Stories Roof Covering Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under theFlorida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection 1 he site of.the work sue ublic notice or notices as are required by the Act. The undersigned agrees to employ only such subcontract rk be o under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. j ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. ' Permit No.. _r!� o� Date �� ?` / / 7 Read, Sworn to and Subscribed before me. Notary Public, State of Florida Building Id(spcctor (/ My Commission Expires to me well known, PLANNING BOARD DATE Chairman Member Member Member Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained froth the Planning Board. A re fee of $1.00 will be charged when such re inspection is made necessary by improper notice for inspetitinn or faulty materials and /or workmanship. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT 4 APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build - ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during prggress of the work. Q �/ Owner's Name and Address . . . . . . . . 1 1. . . . . . . . . 1 � .. .., ._ No ..... Street.__ — Registered Architect and /or Engineer Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done. State work to be done and purpose of building (by floors ). ...._.... 12 7;42/7 .4.3 -6 rzzew ... — _f �.. .., lire ,rt-?- ,PW ••� "ht. .. _4e/4: -z- • i 4,- .e • fZr�; e .Y..IJe�lt • 11. .5 ....��tY1 • t.lt° • and for no other purpose. No. of Stories Disapproved (Signed) Date. Chairman Member Member ...... Z.oZ .6- r 0,:31 6 — U... . ....1�'/� - 7" g • ./ ter Repairs Roof Coverin New Building Remodeling Addition To be constructed of Kind of foundation Estimated Total cost of improvements s..5 3 7 e v Amount of Permit S,. Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the lans an specifications for said building. All notices with reference to the building and its construction may ...- r?o.. ....�%2 .6... ....... . /QS3/ � S • � i . � � be sent to.e ..f)!.. / 9 T Fly. 3 3 /'j The undersigned applicant for this building pertnit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as arc required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks . __._ ._ _ (Signed) � L. JA STATE OF FLORIDA, COUNTY OF DADE. j ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared Notary Public, State of Florida Building Inspector/ My Commission Expires PIl11NNING BOARD _.._......DATE Member Member Member Council Approved Date Disapproved NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has the Planning hoard. A re-inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for materials and /or workmanship. to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. 2� f Permit No..____ �'� ._. -2r Date ._ Read, Sworn to and Subscribed before me. Date hero obtained from inspection or faulty APPLICATION FOR BUILDING PERMIT Owner's Name and Address._ kk L �v Registered Architect and /or Engineer �f7 Name and address of licensed contractor ____ -T,� u7 � �- -. (2 Location and legal description of lot to be built on: U Lot_- Block Subdivision State work to be done and purpose of building (by floors Zone cubage required Distance to next nearest building__ Maximum live load to be borne by each floor_ Member Council Approved the Planning Board. .__ f__._f _ft 1 AA -11. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT Date_ Member _Date Disapproved Notary Public, State of Florida PLANNING BOARD._ __ . DATE Chairman _ -_ Member Member Member 2g Application is hereby made for the approyal of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. 7- 7 , 19 7 No Street Street and Number where work is to be done 4 ' ' .1: / Crz C — - U iO 1 and for no other purpose. New Building Remodeling -__ .)‹ ... Addition epairs No. of Stories To be constructed of Kiel of foundation _ Roof Covering Estimated Total cost of improvements $ /Y4'6 ' - S ----- • ----- Amount of Permit $ plan Cubage Size of Building Lot Mop I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to - - The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be perf ed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. j ss Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared - - - - - -- - - — - -- to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are - f- t� true. yy Permit No._. .. 6-.l _ Date �a__/2 ! _ 7Z Read, Sworn to and Subscribed before me. . Disapproved __ _ Date- ---- - ------ - --_ -- ( Signed) t.-.J . _ , _ C -'-P i Buildin nspector My Commission Expires__ Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from 1 Permit No. Chairman ...... Member Member Council Approved MIAMI SHORES VILLAGE APPLICATION F R BUILDING PERMIT BUILDING INSPECTION DEPARTMENT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. �j p �� Date ��// a/ a //c) 7 , 19. _ Owner's Name and Address V'/ . • O'A _ No..__ _ ..... Street Registered Architect and /or Engineer_ Name and address of licensed contractor _. Location and legal description of lot to be built on: Lo'r... Block Subdivision Street and Number where work is to be done " ^� F Statwork to a done and purpose of building (by floors) / c-Le4-- -- _ /a..�i. c a l f -c.,C/ e - e.... -- -4P Q — --�.C� ''t,�e.�� Wit / / s and for no other purpose. / Z ,Z,, New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundatio hovering Estimated Total cost of improvements $ 3�a - Amount of Permit $ Zone cubage required _Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub- contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the_ . of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. gf Date____.. Read, Sworn to and Subscribed before me. Disapproved (Signed) Building Inspectorl' My Commission Expires Notary Public, State of Florida to me well known, PLANNING HOARD DATE Member Member Member Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING j RECEIVE PERMIT APPLICATI FBC 2001 Permit Type (circle): Building Electrical Owner's Name (Fee Simple Titleholder) W i 11 i am H . Wa 1 ke r 1 ` - Phone # (305 ) 7 5 9 - 5 0 8 0 Owner's Address 444 N.E . 9 6 Street City Miami Shores State Florida Zip 33138 Tenant/Lessee Name Phone # Job Address (where the work is being done) 444 N. E. 96 Street City Miami Shores Village County Miami -Dade Zip 33138 Is Building Historically Designated YES NO X Contractor's Company Name Qualit Roofing Contractor Contractor's Address 13800 N.W. 1st Avenue City Miami State Florida Qualifier Carlos Arocho Architect/Engineer's Name (if applicable) Phone # $ Value of Work For this Permit $ 17,300.00 Square Footage Of Work: 3 0 0 0 s q. Tile 5 0 0 s q. Fla Type of Work: ['Addition DAlteration ❑New ® Repair/Replace ❑ Demolition Describe Work: Tear off old roof to wood deck, tin cap 301h. , i nsta 1 1 ga l v- PR VP drip & valley metals, mop one layer of 901b. ASTM, install tiles with polyfoam adhesiv Flat roof: tin cap glass base sheet, install galvanized eave drip, mop one layer •. • -. 00 Submittal Fee $:SD• Clef 111 41 Permit Fee $ Notary $ -- - Scanning $ (-� Code Enforcement $ Total Fee Now Due $ (Continued on opposite side) Radon $ a s _ Permit No. p? P • 12 Master Permit No. Plumbing Mechanical Roofing Phone# ( 305) 751 -0382 Zip 33168 * * * * * * * * * * * * * * * * **JI * * * * * * * ** F * * * * * * * * * * * * * * * * * * * * * * * * ** * ** ** CO F$ le'rOv 9 Training/Education Fee $ e �6 Technology Fee $ 8,13 Bond $ Structural Plan Review. $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and MR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Owner or Agent The foregoing instrument was acknowledged before me this // day of 19e c . , 2003 , by LJ- I ); . I,4)011''r who is persona ly known to me or who has produced As identification and who did take an oath. NOTARY PUBL Sign: 1 t h Print: My Commission Expires: MY COMMISSION # DD 060579 EXPIRES: October 10, 2005 e i ca State Certificate or Registration No. APPLICATION APPROVED BY: Chc 10/14/03 Signature Contractor The foregoing instrument was acknowledged before me this 1/ day of De _ , 2003 , by ( /1if2(c a who is personally knownio me or who has produced as identification : d who did take an oath. NOTARY PUBLIC: Sign: Print: • .LOU HERN ! DQ y :vMMISSION # D00605i 1 P IPES: October t v ga My Commission Expires: mpetency Holder) ******************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Certificate of Competency No. *********** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** JAN - 8 2004 Plans Examiner Engineer Zoning • 1 Owner's Notification for Roofing Permits issued under the Florida Building Code MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION 1 Section 1524 - High Velocity Hurricane Zones Required Owners Notification for Roofing Considerations rage l ui 1 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. AV yKAV -1. Aesthetics - Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. �2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. 1411/4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. �5. Ponding Water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. VUi') 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scupper in accordance with the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. wner's!Agent's Signature Date http://www.co.miami-dade.fl.us/bldg/roofing_permiting/owner Contra , • is Signature A 2_ 11/25/2003 6 1 High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION Master Permit No. Contractors Name: Job Address: Quality Roofing Contractor, Inc. 444 N.E. 96 Street Roof Category Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic Shingles ❑ Metal Panel /Shingles ❑ Prescriptive BUR -RAS 150 ❑ Other: ❑ New Roof El Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes MI No If yes, what type? ❑ Natural ❑ LPGX Low slope roof area (ft. 500 sq. Section A (General Information) Process No. Roof Type Roof System Information Steep Sloped area (ft. 3000sq. Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Corner Size (a' x a'): Nimom ■mesto ■ ■■■■)♦ ■�■■11 ■■.■m■ mini ■■.■■■ ■■11 ■ ■■■■■ m ■■■xn ■■■■■ ■■�■■A�wriis , twarim■■■�■ ■■ 'G`i/! ■ �A ■�■�■.■m ■ ■ ■ ■ ■�■■■■■■ Yams i st•ILI■■r�1�ammu■ ■ ■ ■■■■i■summ in■ inni�■■■Ir�r.Yam■umaim's� ■amo mli �r■■■■■■■ ii ■■■ ■■�inet �1r■■■�>,u■■■ alitim rosy �r�:■■.■���� ■mini ■■■ ■ ■■■■ ms ■■msimu c= i�a. NoN 1�■fly■:1maiN■■toma IKsaIAsil MEM II ■ ■ ■1.1►\ ■ ■■• 11 il■ 11■ a21•• ■■�i ■ ■ ■ ■ ■ ■ ■111E■•■".■ ■f■■ ■[ ■ _ mommoul mom 1►1t1■ iamm ►�rmum■■■■■■■ ■■■■■■■■■■■■■■mI•■■■ ■1t ■ ■r■■i■ ■■.. 1. u■■■■■► nsaii1 1�■ r .■�■■�■■1r■■!■�■.�■iirm■■.tai■ �■m■ �t■ ■!■■�■ ■■■ I1 1■■ tl ■•I■■fit■\.■■■■■ ■� ■■t•�■■■■■ ■■ ■■■■ ■ ■■■■■■■ � wins= o i∎ amitiia im mmar' ■ ■i ■1 o ii ii ■■ m �■.■■11 •■ ■Si>a!■! ■1■tn ■■ ■ ■■R■N!■ ■ ■m■!' um ■nl ■.■■.■■.■ ■ m m iirnocu■ uut,■�■■s ■■ m ■■imui• �i ■,.m ■lm i■ ■ w ■ ■■• 'U o 1`l••. mmli \■mil■ ■■■ - ■ . ;,U �i■ ■m■1r•■uui�i■ L ■� ■n�■ 11■■ i■ � ■ ■ \ ■ ■� \��5iti■ ■J ■�J►.` . rs�i ■��■ ■ •�■ ■�■ ■ ■� ■� ■X�M■ ■■■ oil■.] ■■'9■'l■ii■■■mI ■■�■■■I►lu ' 11'r \1r1 ■ ■t• ■■■■■ •■■i■ �.■I•■I■ ■ ■1t!.�■■11■ ■J �I ■M_■ r�!!'■■m■■�mt,t �•■ ■■■■■ge.m■ ■■. ■mmiu■■•■■)•■■u.. .rEem Iirms = = = == .1mi ■■ ■■•I■ �■� ■■■! ■■ ■■ ■rtum!.\G!■' ■■ ■ ■� ■M■■■ ■.M■. ■■�� i■ mmm •A!■ ■ ■ ■ ■•1■■ ■■I11U /I>•■■■.■■■■■■ �■■■■m■■■■■!■�,!•� ■ �. �■ atom 11om ■1/■■ unku �iumurnimum■■ ■m...■ ■■. ■��; . � t � f.� � �: 1 '� �,(� �A wo .■ ■•■■ ■)/111\\■ ■ ■■ ■sat•■■ ■t! ■■.■ ■■l •• ■ u !!■■//m•I►■n■■.■u■n■..■!i■■■■■■ mmom■ w ■ ■■■� is mumm ■ ■■■ 1■ r■■aIt!■■■■m\■■ /11i■■ ■�I■�■■A•1■■1■lim!!!! um■F. ■� m■ ■. ■■■■■' ��:= pl amm> •/;•■\■ ■ ■nitm■■`■iTimu�1=:.1■. immo �■ ■�■.■■:■�j■11 ■0 ■■■■■\■i■iriu ■ /monru■■■11■m■■■■m ■ ■■■ ■ ■■■i■11■ 1■ ■■ ■■f'i■lJ■mmil■■■■■\\!9 ■■ unni .■■ ■�� ■■ ■■■■iii ■ ■ ■ ■ ■ ■ ■11 ■ ■ ■ ■ ■■■■ ■ ■■{IA 7■ ■ ••••••••••••• ■• ■111• ■ ■ ■••■ • ■ ■ ■ ■1 ■ ■1 ■•■ ■ ■ •'Z■ ■Ua>■• ■11 ■ .R ■ ■ ■1• ■. �■ 1]'I �l ■ ■ ■ ■■ ■ i •i i •i iii •iii % ••i% •iii •i% ••i ■ i u i •iii•• ii •ii••■i ■ • •■11 Page 2 Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes Total (ft. 35sq. Page 1 of 1 http: / /www.co. miami - dade. fl. us / bldg /roofing permiting /permit_app_section_a.HTML 1/5/2004 System Manufacturer: GAF Material Corporation NOA No:, 02-0408.09 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: I -49.2 Pmax 2: -82.6 Pmax3: 1 -124.3 Maximum Design Pressure, From the Specific NOA System: 5 Deck type: 1" X 6" T & G • These decks require a fastener pull test by an approved test Iabratory Other Deck Type: n/a Joist Spacing: n/a Slope: I 1 /2" High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION Section C (Low Sloped Roof System) Fill in the Specific Roof Assembly components and Identify Manufacturer (If a component is not used, identify as "NA ") Anchor /Base Sheet & No. of PIy(s): n/a Anchor /Base Sheet Fastener /Bonding Material: n/a Insulation Base Layer /Size & Thickness: n/a Base Insulation Fastener /Bonding Material: n/a Top Insulation Fastener /Bonding Material: n/a Insulation Top Layer /Size & Thickness: n/a Page 3 Wood Nailer: 8 Penny nails Base Sheet(s) & No. of Ply(s): (1) Glass Base sheet Base Sheet Fastener /Bonding Material: 1 1/4" R/S nails Ply Sheet(s) & No. of PIy(s): (1) Ply Ply Sheet Fastener /Bonding Material: Type III mopping asphalt Drip Edge Size & Gauge: 3" face 26 ga. 1 '/" R.S. Nails Drip Edge Material Type: Galvinized Metal Hook Strip /Cleat gauge or weight: N/A Coping Metal: n/a Top Ply: Gafglas Mineral Cap sheet Top Ply Fastening /Bonding Material: Type III mopping asphalt Surfacing: n/a FASTENER SPACING FOR BASESHEET ATTACHMENT Fastener Type: Page 1 of 1 Altemate Fasteners: n/a 1. Field: 9 " o/c @ laps & 2 rows @ 9 " o/c 2. Perimeter: 6 " oic @ laps & 4 rows @ 6 " o/c 3. Comers: 6 " o/c @ laps & 4 rows @ 6 " oic NUMBER OF FASTENERS PER INSULATION BOARD I Field: n /a Perimeter: n/a Comer: n/a http: / /www.co. miami - dade. fl. us / bldg / roofing _permiting /section_c_4.htm1 10/29/2003 High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations /Stripping /Flashing, Continuous Cleat, Cant Strip, Base Flashing,Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. Page 3a http: / /www.co. miami - dade. fl. us / bldg /roofing permiting /section_c 4_2.html parapetWa11 Height Ft` MaanRoofHeignt /2 / Ft. Page 1 of 1 1/7/2004 Roof System Manufacturer: MonierLifetile, LLC Notice of Acceptance Number: 02- 1211.08 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1: -45 P 2: -95.1 P 3: -95.1 Maximum Design Wind Pressures, (From the PCA Specific system): 118.9 High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION Roof Slope: 2 1/2 "/12" Roof Mean Height: 13' Ridge Ventilation: n/a Method of Tile Attachment: Adhesive, Large Paddy Polyfoam Polypro Altemate Tile Attachment Method: I n/a Perimeter Width: n/a Clip Spacing for Metal Roof Panels Field: n/a Perimeters: n/a Section D (Steep Sloped Roof System) Comers: n/a Sloped System Description Deck Type: 1" X 6" T & Page 4 Altemate Deck Type: n/a Underlayment type: 30Ib. ASTM felt Insulation/Fire Barrier Board: n/a Optional Nailable Substrate: n/a Fasteners: 1 1/4" R/S nails Cap Sheet Type /Adhesive Type: 90Ib. ASTM felt Roof Covering: Atlantis Shake Tile Roof Covering Attachment Method: Polyfoam adhesive setting Drip Edge Size & Gauge: 3" face 26 ga. Drip Edge Material Type: Galvinized Metal Drip Edge Fastener Type: 1 1/4" R/S nails Hook Strip /Cleat ga. or weight: N/A Page 1 of 1 http: / /www.co. miami - dade. fl. us/ bldg/roofingjermiting/section_d 3.html 1/7/2004 Mean Roof Height in Feet 15' 20' 25' 30' 40' Roof Slope 1 1 1 1 1 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 Page 1 of 1 High Velocity Hurricane Zone Uniform Roofing Permit Application Form MIAMI -DADE COUNTY BUILDING DEPARTMENT ELECTRONIC APPLICATION For Moment based tile systems, chose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each aea of the roof, then the tile attachment method is acceptable. P 1: P 2: -95.1 P 3: 1 -95.1 Method 1 "Moment Based Tile Calculations Per RAS 127" x A 0.24 x A 0.24 x A 0.24 Section E (Tile Calculations) - Mg: 6.0 - Mg: 6.0 - Mg: 6.0 Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From the Table Below: NOA Mf: Mr Required Moment Resistance* *This Table must be used in conjunction with a list of moment based tile systems endorsed by the Broward county Board of Rules and Appeals. Page 5 = Mrl: 4.80 = Mrl: 16.80 = Mr1: 16.80 NOA Mf: 118.9 NOA Mf: 118.9 NOA Mf: 118.9 http: / /www.co.miami- dade.fl.us /bldg /roofingpermiting/section e_3.htm 1/7/2004 MIAMI BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Monier Lifetile, LLC 135 NW 20 Street Boca Raton, FL 33431 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Atlantis Shake & Slate Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Frank Zuloaga, RRC NOA No.: 02- 1211.08 Expiration Date: 12/16/07 Approval Date: 01/09/03 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Sub - Category: Material: 1. SCOPE This renews a system using Monier Lifetile Atlantis Shake & Slate Concrete Roof Tile, as manufactured Monier Lifetile LLC and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Monier Lifetile Atlantis Shake and Slate Tile Trim Pieces 2.1 SUBMITTED EVIDENCE: Test Agency Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Roofing Flat Profile Roofing Tiles Concrete Test Dimensions Specifications 1 =15" w = 10 3 /8" 1 '/<" thick 1= varies w = varies varying thickness Test Identifier 7161 -03 Appendix III 94 -060A 94 -084 25- 7094 -2 25- 7094 -8 25- 7094 -5 Product Description PA 112 Flat, interlocking, high pressure extruded concrete shake and slate roof tile equipped with two nail holes. For direct deck, mortar or adhesive set applications. PA 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Test Name/Report Static Uplift Testing PA 102 & PA 102(A) Static Uplift Testing PA 101 (Mortar Set) (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Date Dec. 1991 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 NOA No.: 02- 1211.08 Expiration Date: 12/16/07 Approval Date: 01/09/03 Page 2 of 6 Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifier 25- 7183 -6 25- 7183 -5 25- 7214 -1 25- 7214 -5 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -77 224 -47099 520109 -1 520111-4 520191 -1 Calculations Calculations Calculations Calculations Calculations Calculations Calculations Calculations Test Name/Report Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain PA 100 Physical Properties PA 112 Static Uplift Testing PA 101 Aerodynamic Multiplier Moment of Gravity 25 -7094 25 -7496 25 -7584 25- 7804b -8 25- 7804 -4 & 5 25- 7848 -6 25 -7183 Aerodynamic Multipliers Two Patty Adhesive Set System Date Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Sept. 1994 Dec. 1998 March 1999 March 1999 Sept. 1999 February 1996 April 1996 December 1996 March 1995 April 1999 April 1999 NOA No.: 02- 1211.08 Expiration Date: 12/16/07 Approval Date: 01/09/03 Page 3 of 6 Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Monier Lifetile Atlantis Shake & Slate Tile 8.5 1.25 0.865 Table 3: Restoring Moments due to Gravity - M (ft-lbf) Tile Profile 3 ":12" 4":12" 5":12" 6":12" 7":12" or greater Monier Lifetile Atlantis Shake & Slate Tile Direct Deck Direct Deck Direct Deck Direct Deck DirectDeck 6.0 5.9 5.8 5.6 5.5 Table 2: Aerodynamic Multipliers - A. (ft Tile Profile a, (ft3) Direct Deck Application Monier Lifetile Atlantis Shake & Slate Tile 0.24 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with RAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater with a minimum of two screws. 4. INSTALLATION 4.1 Monier Lifetile Atlantis Shake and Slate Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations NOA No.: 02- 1211.08 Expiration Date: 12 /16/07 Approval Date: 01/09/03 Page 4 of 6 Table 4: Attachment Resistance Expressed as a Moment - M (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Monier Lifetile Atlantis Shake & Slate Tile 2 -10d Ring Shank Nails 30.9 38.1 17.2 1 -10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2 -10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1 -10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1 -10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2 -10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2 -10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2 -10d Ring Shank Nails' 50.3 65.5 48.3 1 Installation with a 4" tile headlap and fasterners are located a min. of 2W from head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Adhesive 31.3' 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile PolyProN 118.9 PoIyPro TN 40.4 4 Large paddy placement of 45 grams of PolyProTm. 5 Medium paddy placement of 24 grams of PolyProTM. Table 5B: Attachment Resistance Expressed as a Moment - M f (ft -Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Monier Lifetile Atlantis Shake & Slate Tile Mortar Set 39.0 NOA No.: 02- 1211.08 Expiration Date: 12 /16/07 Approval Date: 01/09/03 Page 5 of 6 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved ". 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. WATERLOCK 16Hi° T~ ` PROFILE DRAWINGS tile" WAIERLOCK MONIER LIFETILE ATLANTIS SHAKE & SLATE CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 02- 1211.08 Expiration Date: 12 /16/07 Approval Date: 01/09/03 Page 6 of 6 MI A M I•DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 • MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. • The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the • expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. •BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Deck. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #02 -0408.09 and consists of pages 1 through 21. The submitted documentation was reviewed by Frank Zuloaga, RRC • NOA No: 03- 0501.05 Expiration Date: 11 /04/08 Approval Date:10/23 /03 Page 1 of 21 Deck Type 1: Deck Description: Wood, Non - insulated 19 / 32" or greater plywood or wood plank decks System Type E (1): Base sheet mechanically fastened. All General and System Limitations shall apply. Base sheet: GAFGLAS #80 Uhlman' Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID® 20, RUBEROID SBS Heat-Weld' Smooth or RUBEROID SBS Heat -Weld 25 base sheet mechanically fastened to deck as described below; Fastening Options: GAFGLAS® Ply 4 ®, GAFGLAS Flex PlyT' 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4 ®, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS Flex P1ymi 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —5Z.5 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec (GAFTITE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill -Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6® ply sheet, #80 Ultima, RUBEROID MOP Smooth or RUBEROID 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs. /sq. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. NOA No: 03- 0501.05 Expiration Date: 11 /04/08 Approval Date:10/23 /03 Page 18 of 21 Surfacing: Maximum Design Pressure: See Fastening Above (Required if no cap sheet is used) Install one•of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lbsJsq with an application rate of 1.5 gal./sq.; or GAF WEATHER COAT® Emulsion (Matrix 305 Fibered Emulsion) with an application rate of 3 galJsq.; or GAF PremiumFibered Aluminum Roof Coating (Matrix System Pro Aluminum Roof Coating Fibered 301) with an application rate of 1.5 gal./sq. 2. Asphalt flood coat at an application rate of 60 lbs./sq. ± 20%; plus gravel or slag with an application rate of 400 lbs./sq. & 300 lbs./sq., respectively. 3. Top Coat Surface Seal SB (Matrix 602 SB Coating), Top Coat MB Plus (Matrix 715 MB Coating), GAF WeatherCote or WeatherCote LOW -VOC applied at rate of 1 -1.5 gal/sq. NOA No: 03- 0501.05 Expiration Date: 11/04/08 Approval Date:10/23 /03 Page 19 of 21 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with Ply 4 and Flex Ply 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum 1 %" Dens Deck or Y2 Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbs.sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment dial not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter Hailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B -72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No: 03- 0501.05 Expiration Date: 11/04/08 Approval Date:10/23 /03 Page 21 of 21 Roofing Systems (TGFU)— Continued GAFGLAS #80 Premium Base Sheet may be used in-any of the following systems. "GAFglas Flex Ply 6" is a suitable alternate to "GAFglas Ply 6 ". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid Heat Weld" SBS roofing membraner may be used in lieu of "Ruberoid Mop" SBS products in any applicable Classification. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber/ isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet". 3. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, 2 in. max. Ply Sheet: Two or more layers Type Gl "GAFGLAS Ply 4" or "GAF- GLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 5. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet: One or more layers of Type Cl "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". 6. Deck: NC Incline: 3 Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet". Ply Sheet: One or more layers of Type Cl "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". 7. Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite/ urethane composite, phe- nolic, 1.0 in. min (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type Gl, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule): Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet: Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type Gl. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule)1 ROOF COVERING MATERIALS (TEVT) 4.u1,14. rivvl u1b1 IY1011..I 1101L.J 011 \U J 1 J 11-.1111,1 1.1111LV I VI I 1. 2. 1. 2. 3. 4. 5. LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) 173 Roofing Systems (TGFU)— Continued Cap Sheet: "GAFGLAS Mineral Su1•faced Cap Sheet", hot mopped. Class B Deck: C -15/32 Incline: 3 -1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Two or more layers of Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6" Cap Sheet: Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Deck: C -15/32 Incline: 3 -1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet: Two or more layers of Type Gl, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Class C Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber/ isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers of Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Special Roofing Bitumen" 20 Ibs /sq. COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR Class A Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber/ isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers of Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped with coal tar bitumen. Surfacing: Gravel. COMBINATION HOT AND COLD SYSTEMS Class A Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber or glass fiber, 2 in. max. Ply Sheet: Three or more layers of Type Cl "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: Grundy Industries "al MB Aluminum Roof Coating" at 1 -1/2 gal /sq. Deck: NC Incline: 1 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber/ isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Weather Coat Emulsion" at 3 gal /sq. • Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in., hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. Deck: NC Incline: 2 Insulation (Optional): Isocyanurate, perlite, isocyanurate /composite,. wood fiber and glass fiber, any thickness, mechanically fastened. Base Sheet: One ply Type Gl %r G2, mechanically fastened or hot mopped. Ply Sheet: One or more plies Type Cl or G2, adhered with hot roofing asphalt. Surfacing: "GAF Premium Fibered Aluminum Roof Coating ", 1 -1/2 gal /sq or "GAF Weather Coat Emulsion ", 3 gal /sq. Deck: NC Incline: 1 . Insulation (Optional): Perlite, glass fiber, polyisocyanurate, wood fiber, mechanically fastened, any thickness. MIAMMADE PRODUCT CONTROL NOTICE OF ACCEPTANCE 1'olyfoam Products, Inc. 2400 Spring- Stucbncr Road Spring ,TX 77383 -1132 The expense of such testing will be incurred by the manufacturer. APPROVED: 06 /14/2001 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI. FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 CONTRACTOR 1.ICE:NSINC SECTION (303) 375 - 2527 FAX (305) 375 -2558 CONI•RACrOR ENFORCEMENT DIVISION (305) 375 -2966 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 Your application for Notice of Acceptance (NOA) of: Two Component Polyurethcnc Foam Adhesive under Chapter 8 of the Code of Miami -Dade County governing the use of Alternate Materials and Types of Construction, and completely described herein, has been recommended for acceptance by the Miami -Dade County Building Code Compliance Office (BCCO) under the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify,. or suspend the use of such product or material immediately. BCCO reserves the right to revoke this approval, if it is determined by BCCO that this product or material fails to meet the requirements of the South Florida Building Code. ACCEPTANCE NO.: 01- 0521.02 EXPIRES: 05/10/2006 Raul Rodriguez Chief Product Control Division THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE & PRODUCT REVIEW COMMITTEE This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami -Dade County, Florida under the conditions set forth above. Francisco J. Quintana, R.A. Director Miami -Dade County Building Code Compliance Office 11 s045000I1pc200011templaceslnotice acceptance cover page.doc • - - _ Al .....--• - --•- -..__��..:�.�: � -_-: -- --- tfah u - t.u... /1... F...:LlinarnelennlinP rnm Polvfonm Products, Inc. ACCEPTANCE No. : (11- 0521.02 ROOFING ASSEMBLY APPROVAL CatcEory: Roofing Sub - Category: Roof Tile Adhesive Materials: Polyurethane 1. SCOPE This approves Polypro® AI-1160 as manufactured by I'olyfoam Products, Inc. as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using Polypro® AH 160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems 2. PRODUCT DESCRIPTION Manufactured by Applicant Polypro® AH160 Foampro® RTF1000 ProPack ®30 & 100 Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Dimensions N/A N/A N/A 2.1 Components or products manufactured by others: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list uplift resistance values with the use of Polypro A1-1160 roof tile adhesive. 2.2 Typical Physical Properties: Property Test Density ASTM D 1622 Compressive ASTM D 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 Test Specifications PA 101 Approval Date: June 14, 2001 Expiration Date: May 10, 2006 Results 1.6 lbs. /ft.' 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs. /Ft 3.1 Perm / Inch Product Description Two component polyurethane Dispensing Equipment Dispensing Equipment +0.07% Volume Change a -40 F., 2 weeks +6.0% Volume Chan Humidity, 2 weeks . u Frank Zuloaga, RRC Product Control Examiner Polyfoam Products,. Inc. • ACCEPTANCE No. : 01- 0521.02 Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for tire rating. 3.2 Polypro® AH 160 shall solely be used with flat, low, & high tile profiles. 3.3 Minimum underlayments shall be in compliance with the Roofing Application Standard RAS 120. 3.4 Roof Tile manufactures acquiring acceptance for the use of Polypro® AH 160 roof tile adhesive with their tile assemblies shall test in accordance with PA 101. 3.5 Roof Tile manufactures acquiring acceptance for two paddy placement with the use of Polypro® AH 160 roof tile adhesive with their tile assemblies shall test in accordance with PA 101 and with section 10.4 as modified herein. w F' 2 MS 4. INSTALLATION 4.1 Polypro® AH160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of Polypro® AH 160. 4.2 Polypro® AH 160 shall be applied in compliance with the Component Application section and the corresponding Placement Details rioted herein. The roof tile assembly's adhesive attachment with the use of Polypro® AI-( 160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 4.3 Polypro® AH 160 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Polyfoam Products, Inc. Polypro® AI-1160 Operating Instruction and Maintenance Booklet. 4.4 Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. Polyfoam Products Inc. shall supply a list of approve,1 applicators to the authority having jurisdiction. 4.5 Calibration of the Foampro® dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0 -1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No other settings shall be approved. 4.6 Polypro® AH 160 shall be applied with Foampro RTF 1000 or ProPack® 30 & 100 dispensing equipment only. 4.7 Polypro® AH 160 shall not be exposed permanently to sunk 3 Frank Zuloaga, RRC Product Control Examiner Polyfoam Products, Inc. ACCEPTANCE No. : 01- 0521.02 4.8 Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after Polypro® A1-1160 has been dispensed. 4.9 Polypro® AH 160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Flat, Low, High Profiles High Profile (2 Piece Barrel) Flat, Low, High Profiles Flat, Low, High Profiles Placement Detail #1 #1 #2 #3 Single Paddy Weight Min. (grams) 35 17 /side on cap and 34 /pan 24 Two Paddy Weight per paddy Min. (grams) N/A N/A N/A 8 5. LABELING All Polypro® AH 160 containers shall comply with the Standard Conditions listed herein. 6. BUILDING PERMIT REQUIREMENTS 6.1 As required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. 4 Frank Zuloaga, RRC Product Control Examiner Polyfoam Product, Inc.. ADHESIVE PLACEMENT DETAIL 1 SINGLE PATTY ACCEPTANCE No. : 01-0521.02 e or 11 Place enough adhesive lo achieve 11 to 23 Opt Foul 24' s for equate Inches In contact with the pan Ill* deep Pike *Pilule" 2) Turn covers upside down. Place adhesive 112 la. To 1 hi. From outside edge of cover tile. Then Instill the Lk Na throu plastic cement U Remov 1 Put0 of U14 iris course cover Ills. Abut to wand course of pal Wes. Ensure save awl of pal and cover Wei are flush of 'MI line. Errs closure honer shown) 5 Weephole Fuel.:. Frank Zuloaga, RRC Product Control Examiner 0900nal Pokt-up Maur os longitudinal edges of tile Sheedilog Polyfoam Products, Inc. ADHESIVE PLACEMENT DETAIL 2 SINGLE PATTY Nall through plastic cement Nail through plastic cement 6 ACCEPTANCE No.: 01- 0521.02 Frank Zuloaga, RRC Product Control Examiner Po lyfoarn Products, Inc. ADHESIVE PLACEMENT DETAIL 3 .. DOUBLE PATTY Nall through plastic cement Singk paddy 3 in. under tile x 3 In. SIngle paddy on under. layment Single paddy on top of tile Paddy (between tile) Paddy (under tile) bye course 2 in. X 7 In. medium size paddy save Fascia course only Nail through plastic cement t 4in.x 3 In. Single paddy on underlayment Single paddy on top of tile Ease Course 7 ACCEPTANCE No. : 01-0521.02 Nail through plastic cement Underlayment N4In. x 3m. 41n. Single paddy on under. layment Single paddy under Ole Single paddy between tile 2 in. x 7 In. medium size paddy save course only Single paddy on top of tile Eave Course Fascia Weephole Eave closure Drip edge Single paddy between tile Eave Closure 2 In. x 7 In. medium size paddy cave course only Fascia Frank Zuloaga, RRC Product Control Examiner Polyfoant Products, Inc. ACCEPTANCE No. • 01- 0521.02 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documents, including test - supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approval ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a. There has been a change in the South: Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes. b. The product is no longer the same product (identical) as the one originally approved. c. If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product. d. The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5. Any of the following shall also be grounds for removal of this Acceptance: a. Unsatisfactory performance of this product or process. b. Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all time. The engineer need not reseal the copies. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Notice of Acceptance consists of pages I through 8. END OF THIS ACCEPTANCE 8 Frank Zuloaga, RRC Product Control Examiner NOTICE OF COMMENCEMENT A RECORDED DOPY MUST U POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain teal property, and in accordance with Chapter 713. Florida Statutes. the following information* provided in this Notice of Commencement. 1. Legal description 01 properly and street address: 444 N.E. 96 Street 3.Owner(s) name and address: William H. Waiker 11 btlersst in forty: Owner Name and address of lee simple titleholder: N/A 5. Surety :(Payment bond required by owner from contractor, if any) Name and address: N/A Amount of bonds 0 0 6. Lender's name and address: N/A Notary Public Print Notary's Name My Commiasbn Expires Miami Shores, Florida 33138 2. Description of improvement: Reroof to a new Tile and Flat Cap sheet roof. 444 N.E. 96 Street Miami Shores, Florida 33138 4. Contractor's name and address: Quality Roofing Contractor, Inc. 13800 NW 1 st Ave, Miami ,Florida 33168 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 715.13(1 Na)7., Florida Statutes, Name and address N/A 6. In addition %Mime, Owner designates the following persons) to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b), Fiaride Statutes. Nance and address: N/A 9. Expiration date of this Notioe of Commencement: (the expiration date is 1 year from the date of recording unless a Onward daft Is specified) LJ.0 V.A1i1 . re of Owner (� Print Owner's Name /Ili �tan'1 r,Jk d 14 Sworn to and subscribed before me this ,/I day. of Dec . . 20 MARYL170 HERNANDEZ .` ,a‘ MY f.OMMISSION a nn nsnc7a �`• .%,:� a EXPIRES: October 10, 2005 '..t;fr Bonded Thru Notary Public Underwriters F LO 0'r " COUNTY Cr DA the HEREBY C_RTIF1 that this is /7 C : , o of r �s office on _ �ngmal filed m, tL. AMINE SS my hand and Officio IARVEY IbUVIN. CLERV CFH 200480011959 OR Bk 21955 Ps 4427; Ups) RECORDED 01/07/2004 10:29:46 HARVEY RUVIN+ CLERK OF COURT MIAMI -DADE COUNTY? FLORIDA LAST PAGE Prepared by Carlos Arocho Quality Roofing Contractor, Inc. Address: 13800 NW 1 st Avenue Miami ,Florida 33168 A L .' ;sal. i and County Courts 111111111111111111111111111111111111111111111 Miami Shores Village 10050 NE 2nd Avenue Phone: 305- 795 -2204 Permit Number: BP2004 -12 Printed: 1 /13/2004 Applicant: WILLIAM Owner: WALKER JOB ADDRESS: 444 NE 96 Contractor QUALITY ROOFING CONTRACTORS INC Contractor's Address: 13800 NW 1 AVE Local Phone: 305 - 751 -0382 Parcel # 1132060140580 Permit Status: APPROVED Permit Expiration: 7/6/2004 Construction Value: $17,300.00 Work: NEW ROOF COLOR THRU TILE AND FLAT ROOF Signed: (INSPECTOR) Building Permit WALKER WILLIAM ST Page 1 of 1 Legal Description: MIAMI SHORES SEC 2 PB 10 -37 LOTS 5 & E1/2 LOT 6 BLK 53 LOT SIZE 75.000 Fees: Description Amount FEE2004 -276 Building Fee $325.00 FEE2004 -277 CCF $10.80 FEE2004 -278 Training and Education Fee $3.60 FEE2004 -279 Technology Fee $8.13 FEE2004 -280 Scanning Fee $6.00 Total Fees: $353.53 Total Fees: $353.53 14 Total Receipts: eceipts u :0u _,cam 3 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: 14) MIAMI SHORES VILLAGE, FLORIDA a- rto - ,11 El ❑ PERMIT N? 12482 DATE n Work to be performed under this Permit BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building ,' Architect Contractor r . • or Builder yr.,,• -- ia* .+• Legal Lot Description Address of Building This permit is granted to' the contractor or builder named above to construct the building or to tall the equipment or device described in the application herefor in strict compliance with, all ordinances pertaining thereto and with the understanding tha e work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the or drawings or in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Bl. • Si Subdi- vision Value of Project $ ' 6 6 f' CONTRACTOR OR BUILDER BY Contractor's License No Amt. of Permit $ 1/4,..„63y ./ ,rr trawl 195 INSPE In consideration of the issuance to me of this permit -.I . agree to perfo the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, draw fts, ^sta't ents'or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. AUTHORITY MIAMI SHORES VILLAGE BUILDING DEPARTMENT L 305- 795 -2204 Building Inspection Request Date Type Insp'n — T - 7(Ct 5 1 -1 Permit No. 6P O' t2_ ( Name 1 0 I b€ V G 1 Address '1 (-16 1 v t - l �Q s4- Company Cko Id Phone # Inspection Date Approved Correction Re- Insp'n Fee -sri3 MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Date Type Insp'n f Permit No. G ^ U' O 4 - t a / Name Ili r Address `'l 1 L CO 3 Company quc«k Phone # Inspection Date lig-a)OH Approved Correction Re- Insp'n Fee ❑ Date Type Insp'n Permit No. MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request (. I Lt\ O'4 1200 .*` ni 930 c4 — �a Name l Q/1'l Address 44 4 (LC 9 ro 5T Company OOJ< +-N ROT-4 Phone # e JOS 7 l ( ' ° Inspection Date (2 I — t l M A pp o) . Correction ❑ Re- Insp'n Fee ❑ 2 3a) Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test P or F) Test Location Uplift Pull Test(P or F) Test Location Uplift Pull Test(P or F) 1 ?A 4 - -t , 26 p� I, tC��7 51 FA 4.3). 76 2 27 52 i7 3 28 53 78 4 29 54 79 5 30 55 `_- _ 80 6 31 56 81 7 32 57 82 8 33 58 83 9 34 59 84 10 35 60 85 11 36 - 61 86 12 37 62 87 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 46 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 L� 75 100 U.S. SOUTH Engineering & Testing Lab., Inc. 6065 N.W. 167th Street, Suite B -23 • Miami Lakes, Florida 33015 Telephone: (305) 558 -2588 • Fax: (305) 362 -4669 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPILANCE PROTOCOL TAS 106 SITE SPECIFIC INFORMATION Project N Owner's Name \A/AA k -R Permit # V - lZ N Job Address 444 e lc, .-r.., MIA, M t S.44 D ES, F. Roofing Contractor C20 A.. 4 t T y - g_ O 0 t i.34 Type of Tile: _F_341 T 0-.- 6 -T Date Installed: �- t 3 ' - o Approximate Roof Height: 0 feet Roof Pitch: 3 /Z ' I Z Type of Access to Roof: Scaffolds Other Approximate Square Footage of Roof '3 ft \.Ladder Required Testin Force: 35 lbs. Testing Equipment: Chatillion 100 Date Tested: •' I ° I " IN ACCORDANCE V0.711 T '. CRITERIA OF PR • OCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTS'y.TE ": 011".°111.111." 1 / / 1 /i� • THIS REP r ' < AITTED BY Civil Engineer: Lab Certification # 98- 0608.04 State of FL Certificate Authorization # 4100 TEST RESULTS P = PASS, F = FAIL P.E. f/9 57_4- PRINTED BY: UNIQUE GRAPHICS: 954 - 484.9923 FAX: 954-484-9967 5956 1 1 1 I 1 1 j j i j 1 1 I j j i I i 1 1 t• I. I I I 1 I I I 1 i i RU � 1 � I H I 1 i 1 /L9 I . 13"' 1 I id/ - 1 , - ''' ___- 1 - -� 41. Ili -- -� Iriwal gr 4 j l I l I . I t it . - ? I -- -- • � J ►. - _ 1 1- • - I I i I .,170, -I * I '' __ -- - __ - - - -1__ -- __-_----1____ - f I - -. - �� -- -- - ________ I I -, - r - I 1 — WAIF �I � i . __ -- - _ 1 I _ �II - -- - 1 _ - I r -- -) I i ® ' I . 101 II f 1 _ I I ii .III II- I I - Ii 1 1 I i II_ - _I i ► 1 i I _ I I I 1 1 ! 1 • ,. : CF FO OF 444 N q/0 , 6°014 4 , �1 . ' _ 0 : . Q . EY it BUILDING CI MIAMI SHORES VILLAGE, FLORIDA ELECTRICAL ❑ PLUMBING ❑ PERMIT N? 8446 ROOFING k Owner of Building hN !t: if.. a ♦fir Architect Contractor or Builder 4 ti 1 Ti' .4 +h .0_ ' j___4__ 4, IP Legal Lot Description I I BI Address of 44 4 � r Building �"' / '� c; CONTRACTOR or BUILDER Work to be performed under this Permit BY f j / 4 ; t'1 nl Date 2 - 19_47 Contractor's License No. ' ] !r. • MJTHORITY t tj Subdi- vision pp�� Sq. Ft. Value of Amount of { Project $ II Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plan or dra • s or in the statements or specifications and that he assumes respon- sibility for work done by his agents, ser n�q \j) or e oyees ( Signed • § ,EitsOTOR) BY In consideration of the issuance to me of this permit I agree to pe/ rm the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, stay s nts or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by :: er, myself, rriy agent, servant or employee. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village,. Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. J Date I iJ A J s Owner's Name and Addre street__ 19– – ss_ \' i k �l U e. v L a iQ I` ( ~ t- Y• � e b �? No./ __`�__�_Q � _1s�1 V � Registered Architect and /or Engineer 1 j Name and address of licensed contactor _ -r__ a_ 4 _ ! � �' _ ! G h d' s, nra ' / ��) � ? _ ` ^ Location and legal description of lot to be built on: � Lot Block Sub 'vision " Street and Number where work is to be done _______ _ 4_ __NS___9_/7 __ __ State work to be done and purpose cif puildin (by floors) �a !'5 7- 1 ".� 4 +v - and for no other purpose. New Building Remodeling Addition Repairs No. of Stories___ /____________-- To be constructed of Kind of foundation Roof Coverin_di.t_L1_!3 -_LL ' _ Estimated Total cost of improvements $ I 5__l) • e) - - _ _Amount of Permit $ .6 0 Zone cubage required plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereb submit all the lans and specifications for said building. All notices with reference to the building and its construction may, be s The fo this bu din J ermit does hereby certify � that � ' J �� '' �� f g permit y y he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such ublic notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this permit, as are licensed by Miami Shores Village. r Remarks (Signed -- -,��� t�P• . - -` *"i',*,1, '_ \ -' " t ° " 1 STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, therein by him stated are true. Permit No Disapproved (Signed) Building Inspector Date Date / - S ° / Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires to me well known, PLANNING BOARD DATE Chairman Member Member Member _ Member Member Council Approved Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship.