320 NE 96 St (12)Issue Date: 9/20/2006 Owner's Name: FE PELOBELLO Permit Type: Roof Work Classification: Roof - New Job Address: 320 96 NE Contractor(s) QUALITY 1ST ROOFING Phone Primary Contractor Yes Additional Information Miami Shores Village, FL Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Fax: (305)756 -8972 Permit Expires: 03/19/2007 Type of Work: Re -Roof Classification: Residential Additional Info: In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. Parcel #: Block: Section: Tin Cap Hot Mop Tile In Progress Up Lift Report Final Roof Permit Status: APPROVED Permit Number: RF -9 -06 -2354 Phone: 1132060135980 Lot: PB: Total Square Feet: 1000 Total Valuation: $ 7,990.00 Re uired Ins • ections Fees Due CCF Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $4.80 $1.60 $250.00 $9.00 $6.25 $271.65 Invoice Number RF-9-06-26208 Total: Amt Due $271.65 A�PX FR 9PAM Amt Paid Building Department File Copy Applicant Signature NOTICE: In addition to the requirements of this permit. there may be additional restrictions applicable to this property that may be found in the public records of this county. AND THERE MAY BE ADDITIONAL PERMITS REQUIRED FROM OTHER GOVERNMENTAL ENTITIES SUCH AS WATER MANAGEMENT DISTRICTS, STATE AGENCIES, OR FEDERAL AGENCIES. Inspection Date: 11/14/2006 Inspector: Grande, Claudio Owner: PELOBELLO, FE Job Address: 320 96 NE Project: <NONE> Miami Shores Village, FL Contractor: QUALITY 1ST ROOFING Building Department Comments Monday, November 13, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Phone Number Lot: C, 15 En CL, Permit Number: RF -9-06 -2354 Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Parcel Number 1132060135980 Page 2 of 2 l'(rf \ Passed Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 11/14/2006 Inspector: Grande, Claudio Owner: PELOBELLO, FE Job Address: 320 96 NE Project: <NONE> Miami Shores Village, FL Contractor: QUALITY 1ST ROOFING Building Department Comments Monday, November 13, 2006 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Phone Number Lot: C, 15 En CL, Permit Number: RF -9-06 -2354 Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Parcel Number 1132060135980 Page 2 of 2 1 b Passed 1' Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: INSP-26984 Permit Number: RF -9 -06 -2354 Inspection Date: 10/13/2006 Inspector: Grande, Claudio Owner: PELOBELLO, FE Job Address: 320 96 NE Project: <NONE> Contractor: QUALITY 1ST ROOFING Building Department Comments Friday, October 13, 2006 Miami Shores Village, FL Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Ca 13 ZOE Block: Permit Type: Roof Inspection Type: Hot Mop Work Classification: Roof - New Phone Number Parcel Number 1132060135980 Lot: Page 2 of 2 Inspection Number: `1 9852 Permit Number: RF -9 -06 -2354 Inspection Date: 10/13/2006 Inspector: Grande, Claudio Owner: PELOBELLO, FE Job Address: 320 96 NE Project: <NONE> Friday, October 13, 2006 Miami Shores Village, FL Contractor: QUALITY 1ST ROOFING Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Cif 1 3 2006 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060135980 Lot: Page 1 of 2 Infractio Passed Comments TIN CAP SPACEING False (� Passed Inspector Comments st, �{ r 5Qe /3-0 XD C:! Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Number: `1 9852 Permit Number: RF -9 -06 -2354 Inspection Date: 10/13/2006 Inspector: Grande, Claudio Owner: PELOBELLO, FE Job Address: 320 96 NE Project: <NONE> Friday, October 13, 2006 Miami Shores Village, FL Contractor: QUALITY 1ST ROOFING Building Department Comments Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Cif 1 3 2006 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132060135980 Lot: Page 1 of 2 Miami Shores Village Building Department D IEC EW 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 SEP IL 5 MO 10 Tel: (305) 795.2204 Fax: (305) 756.8972 BUILDING (it Permit No.'s_ Cy - -t PERMIT APPLICATION Master Permit No. FBC 2004 Permit Type (circle): Building Electrical Plumbing Mechanical Owner's Name (Fee Simple Titleholder) b- /tick_ P_ /fl i ll e.--//0 Phone # Owner's Address 3 /I,E 96 M J4 City 7 Ioa A : (Ao � State Fr Zip 33i, , Tenant/Lessee Name Phone # Job Address (where the work is being done) 3.20 City Miami Shores Village County Miami -Dade FOLIO / PARCEL # /1" e 7a 06 - 013 -5'0— Is Building Historically Designated YES NO a� 601,J,14, is¢ 16 y� lce 1. C,L City '� /a 4, State ri Qualifier Name fir. , La .4 ,‘ Phone # State Certificate or Registration No. CCU /3 2 ? 0 Contractor's Company Name Contractor's Address Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 7/ 9 gQ ©O Square / Linear Footage Of Work: 1 0 OD j Type of Work: ['Addition ['Alteration ❑New Repair /Replace ['Demolition Describe Work: 4—i-D f b Submittal Fee $ Permit Fee $ Notary $ Training/Education Fee $ G(3 Phone # Zip Certificate of Competency No. CCF $ 4 Technology Fee $ 3 3 1 3 ? e77 -6((- )“3 Zip CO /CC Scanning $ SOO Radon $ DPBR $ Zoning $ Bond $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ , 1 See Reverse side -+ Bonding Company's Name (if applicable) '*� _ Bonding Company's Address City Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS. and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature +% As identification and whp,diti.L , .Agtkt.,.., JENNIFER ANN SKYLES NOTARY PUBLIC: ..!:V t.umm# D00278060 Ay ( h' Ears ) 1 118t2C. Print: My Commission Expires: APPLICATION APPROVED BY: (Revised 02/08/06) r, � a � I Owner or Agent State Zip Rwwad thru (80414a;.-`7:. ;‘," Flonaa Signature Sign Print: ***************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ( e.4A44-te-- 4 . Contractor The foregoing iinstrument was acknowledged /��before me this &t( The foregoing instrument was acknowledged before me this day of S( . p 1 , 20 V b , by Eivc /" t; /1)k, /(0 , day of 67' , 20 04 by eZe 6 P . who is personally known to me or who has produced 04 who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: JENNIFER ANN SKYLES u•a''g Ztomm# or)027 (`= E,nues )0 I18/7c:. Ro,aad thru (80U14.12-'7N. Flonaa Nona A ;^„a„ t„ . My Commission Expires: i 1 C. C' ) . r i 6c, Plans Examiner Engineer Zoning Permit No. Tax Folio No. - 5q' PQ NOTICE OF COMMENCEMENT State of Florida (Space above this line reserved for recording office use.) County of Mlaml -Dade The undersigned hereby gives notice that Improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Description of property (or attach legal description); Lot ! 1 to Block T' subdivision: IAM( IC flOaS 45 2E General description of Improvement: - Aloir PROPERTY OWNER Name and Mailing Address CLIP 1 j� �G11(�. / LeD 320 fJ C 9G ,Si /�i,�/Ni ���f c X 3/3 6 Interest in property: /7 Name and address of Fee Simple titleholder (If other than Owner): Af/( CONTRACTOR Name and Address: Quality First Roofing, Inc. 6760 Muskogee St, Orlando, FL 32807 ph: 407 - 679 -4553 If Surety Bond, Name and address of Surety Na "' ' ') = r and Bond Amount $Na LENDER Name and address: Na 713.13(I)(a)7., Florida Statutes: EXPIRATION DATE OF THIS NOTICE: Signature of Owner rr rr , Printed Name: 1! f 1!'>� \! tio Signature of Owner Printed Name: SWORN TO AND SUBSCRIBED before me this day of Ne-,ei )1 Signature of Notary: ` Printed Name: (affix seal) Return Recorded Documen • to: y7% JILL B FRANK MY COMMISSION ♦ DD469S67 - 10/ O EXPIRES: Sept. 7,2009 007) 96180751 Florida Notary S. Mosoom H:(fOrmslparmitslNOTICE of Comma c}17 k IN H d Dt fc_ , 1111111 1111111111111111111111111111111111 1111 r .7i � u,.,. It V: �J :. C :IFFI 2� 4885. OR Bk 24931 P9 1501; (1ps) RECORDED 09/21/2006 10:37:19 HARVEY RUVIN, CLERK. OF COURT MIAMI -DADE COUNTY? FLORIDA LAST PAGE Persons within the State of Florida designated by Owner upon whom notices • er do men =_'served astp�ovided�b ine In addition to himself, Owner designates of to receive a copy of the Lienor's Notice as provided in Section 713.13(a)(b), Florida Statutes. "• (expires ONE (1) YEAR from the date of recording unless a different date Is specifled) Book24931 /Page1501 CFN #20061014885 Page 1 of 1 Primary Zone: 1400 SINGLE FAMILY RESIDENCE CLUC: 0001 RESIDENTIAL- SINGLE FAMILY Beds/Baths: 4/3 Floors: 1 Living Units: 1 Adj Sq Footage: 3,322 Lot Size: 12,070 SQ FT Year Built: 1952 Legal Description: MIAMI SHORES SEC 1 AMD PB 10 -70 LOT 7 & W35FT LOT 6 BLK 44 LOT SIZE 85.000 X 142 OR 15332 -118 1291 1 Year: 2006 2005 Land Value: $318,730 $272,248 Building Value: $277,736 $239,399 Market Value: $596,466 $511,647 Assessed Value: $185,049 $179,660 Homestead Exemption: $25,000 $25,000 Total Exemptions: $25,000 $25,000 Taxable Value: $160,049 $154,660 Folio No.: 11 3206 - 013 - 5980 Property: 320 NE 96 ST Mailing Address: ELVA & FE PELOBELLO 320 NE 96 ST MIAMI SHORES FL 33138 -2718 Miami -Dade My Home :i Show Me: I Property Information Search By: (Select Item J CI Text only Ir-1 My Home 11 i/ 111'o .aaeo o � Property Appraiser Tax Estimator Summary Details: Proaerty Information: Sale Information: Sale O /R: Sale Date: Sale Amount: 15332 -0118 12/1991 $160,000 Assessment Information: @@ 16 Digital Orthophotography - 2005 http://gisims2.miamidade.gov/myhome/propmap.asp 0 IJ %;c1 We appreciate your feedback, please take a minute to complete our survey. My Home I Property Information I Property Taxes I My Neighborhood I Property Appraiser Home I Using Our Site I About I Phone Directory I Privacy I Disclaimer If you experience technical difficulties with the Property Information application, please click here to let us know. E -mail your comments, questions and suggestions to Webmaster Page 1 of 2 114 ft Web Site ® 2002 Miami -Dade County. _ All rights reserved. _� , 9 v II SFP 1 5 2006 fV 09/05/2006 R4402.13.1 Scope. As it pertains to the section, it is the responsibility of rooting contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations.' Additionally, the following items should be addressed as part of the agreement between the owner ant ti e contractor. The owner's initial in the designated space indicates that the item has been exprained. • • •'• 1. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS for purpose of providing that the roof system meets the wind resislaie.e:and v'atgr•: • • instruction performance standards. Aesthetics (appearance) are not a cnnsideration • respect to workmanship provisions. Aesthetic issues such as color or trchittcturah... •• appearance, that are not part of a zoning code, should be addressed ag par of the agr ©ernent • • between the owner and the contractor. • • • • • • • • • • • .. • 2. Renailing wood decks: When replacing roofing, the existing wood roof deck m y ave to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation etwl5 een neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. The provides the option of maintaining the appearance. 5. , LQ/ Ponding water: The current roof system and /or deck of the building may not drain well and may cause water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Aesthetics - Workmanship: the workmanship provisiorAa.S6ction:M1402 are 6. ��4 /Overflow scuppers (wall outlets): It is required that ral •water flow off so that e roof is not overloaded from a buildup of water. Perimeter /edge .l r ot�7` extension may block this discharge if overflow scuppers (wall out e s a e no r o i d. It may be necessary to install overflow scuppers in accordance with h= - it �ent� of Sections R4402, R4403 and R4413. U Owyfer /Ag! nt's Signature Il obfo 7. Ventilation: Most roof structures should have so airflow thr gh the interior of the structure assembly (the buil amount of attic ventilation shall not be reduced. It may be benefici venting which can result in extending the service life o the roof. Date Co t ractor Signatire `" ' v Dafe I�, SEP 1 5 2006 ,) BY - 2 35 - f_ 11 i = r � i 1 1 r , - � 4 r r1 r t J j - 4 r 1 ' I� -, 1 T f j 11 + f ' r - . i . { F1 ,, r. -- _ .. _ - - Contractor's Name Florida Building Code Edition 2004 High Velocity Hurricane Zone Un n Permit Application Form Master Permit No. Process No. Ou-'J' /$f /(o cy,9 � '� yy11 Job Address ado /L1 /' cj� f .5 I art, $ c of 7213 '..' • E -L ow Slope ❑ Mechanically Fastened Tile ❑ Asphaltic ❑ Metal Panel /Shingles Shingles ❑ Prescriptive BUR - RAS 150 Section A (General Information) ROOF CATEGORY .... • • •••• • • • • • • • • • • •- • ❑ Mortar /Adhesive Set Tile ❑ Wood Shingles /Shakes ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Slo )dd oof Area (SF) Total (SF) • • .• ...• • .• • .• ...• •••- • • •••- .•• • .• • • ROOF TYPE ❑ New Roof ❑ Re- Roofing ❑ Recovering ❑ Repair ❑ Maintenance Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels; clearly identify dimensions of elevated pressure zones and location of parapets. .: • • Fill in Specific Roof Assembly Components and Identify Manufacturer (If a component is not used, identify as "NA ") / System Manufacturer: ,t) 1 145 1)5A NOA No.: /9i _ 05-a� Design VVind Pressures, From RAS 128 or Calculations: Pmax1: / Pmax2: P'" Pmax3: Max. Design Pressure, ,from the specific NOA System: Gauge/Thickness: -i r t Deck: Type: Slope: Insulation Base Layer: /U7* Florida Building Code Edition 2004 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) At. Anchor /Base Sheet & No. of Ply(s): Anchor /Base Sheet Fastener /Bonding Material: Base Insulation Size and Thickness: Base Insulation Fastener /Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener /Bonding Ma rial: Base Sheet(s) & No. of Ply(s): A[ 1 / 4A Base S t Fastener /B Material: Ply Sheet(s) & No. of Ply(s): 1 � F(r~40 Ply Sheet Fastener/Bonding Material: / Top Ply Fastener /Bond n Materi I:// Surfacing: •••• • •• • • • Fastener Spacing for Anc iOnlAase Shggf • Attachment • •• •• • •••• •••• • • Field: 9 " oc @ Lap, # 12 & 2 " oc r • ••• Perimeter: > " oc @ Lap, #'RoVDS • . @• • r " oc Corner: 4 " oc © Lap, 10:Row @. " oc • • • • • • • •• • Number of Fasteners Per Insulation Board Field Perim • • a • • •• • orner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 2 - v 44„. O(r r /' tvf c FT s v FT A •••• • • • • Parapet Height /9 Mean - Roof Height • • • • • r: 'MIAM PR D CT C 1 ' OL NOTI OF A CEPT • CE Polyglass USA Inc. 150 Lyon Dr. Fernley ,NV 89408 Your application for Notice of Acceptance (NOA) of: Polyglass Modified Bitumen Roof System Over Wood Decks under C>' °pier 8 of the Code of Miami -Dade County governing the use of Al at MateriatYddd Typls Construction, and completely described herein, has been recommended for acceptance by t1ve 1`i ..I fade • County Building Code Compliance Office (BCCO) tinder the conditions specified herein. This NOA shall not be valid after the expiration date stated below. BCCO reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, BCCO may revoke, modify, or suspend the use of such product or material immediately- BCCO reserves the right to revoke this approval, if it is determined by BCCO that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.; 01-0529.01, EXPIRES: 09113/2006 Raul Rodriguez Chief Product Control Division PECIFIC AND GENERAL G CODE & PRO REVIE C E This application for Product Approval has been reviewed by the BCCO and approved by the Building Code and Product Review Committee to be used in Miami-Dade County, Florida under the conditions set forth above. _ i TFIE Co APPROVED: 09/13/2001\ ET E ADD \ 1s045009Ipc2000 11templetes\notice acceptance cover page.dot Internet mail addreset postmaster ®bnildingcodeooline.com JI \J 1 IWAI ONAL PA CONDITIONS MIAMI-DADE COUNTY, FLORIDA METRO -DARE FLAOLER BUILDING ]BUILDING CODE COMPLIANCE OFFICE METRO-DADE FLA,GLER BUILDING 140 WEST F1.AGL13R STREET, SUITE 1603 FLOR1]DA 33130-1363 4305) 375- 2901'FA X (305) 37 3.29Q% • COrfTRACFO IirCEI S cr1o14 • • 1375 -252f PAN (305) 315-`1$3$ • • • • coNTRA,Graall ENFORCp:lOI 'NT DItA • , 3 -29166 ?AX'(305) 374.22$ • .• • • XialDucr pro4,1 )L BIIISPCItt • • (MI5) 375-2901 FAXX(305) 3'Ft•60a9 • • • • •••• • • Francisco ?. O iintana, R.A. Director Miami -Dado :'cunty Building Code CompPanre Office $omepage: hittp://www.bliilehri,..mdeorlioe'xotri • • POLYGLASS USA, INC. ROOFING ASSEMBLY APPROVAL Catettorv• Roofing ub- Category SBS /APP/Tpp, Modified Approval Date: September 2 13 0 Bitumen • •••• Expiration Date Sutt ��mb r 9, 20 6 k e: Maximum Desi n pressure Fire Classification: rodnct Polyflex Wood -82.5 psf See General Limitation #1 D�eneions 32' 10" x 3' 3 -3/8" ASTM D 6222 Polyflex 0 32' 10" x 3' 3 -3/8" ASTM D 6222 Polyfle, G FR 32' 10 x 3' 3 -3/8" ASTM D 622.2 Polybon,d Polybond G • Elastoflex S6 32' 10" x 3' 3 -3/8" ASTM D 6222 32' 10" x 3' 3 -3/8" ASTM D 6222 32' 10" x 3' 3 -3/8" ASTM D 6164 Elastoflex S6 © 32' 10" x 3' 3 -3/8" ASTM D 6164 Elastoflex S6 G FR 32' 10" x 3' 3 -3/8" ASTM D 6164 Blagtoshield TS4 32' 10" x 3' 3 -3/8" ASTM D 6164 Elastoshield TS4 FR. 32' 10" x 3' 3 -3/8" ASTM D 6164 Elastoflex V 32' 10" x 3' 3 -3/8" ASTM D 6163 2 NAGE 04/25 Acceptance No.:. 01- 0529.01 .. • • .. • • • •••• • •••• • •••• TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BYAR&! ... Test Prc • • S ° n Desc a eons •••• Torch applied, polyester rginf, APP'dtbdified bitumen membrane with a Mb offpolyelly1 back face and a smooth or sanded top sur • Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Torch applied, polyester. reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface and ire retardant chemistry_ Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Torch applied, polyester reinforced, API' modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a polyethylene or sanded top surfa Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a bum off polyethylene or sanded back face and a granule top surface. Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface ands retardant chemistry. Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn offpolyetlylen or sanded back face and a granule top surface, Torch, hot asphalt or cold adhc.:i,j applied, polyester reinforced, SBS modified bitten( m .nbranc with r buns off polyethylene or sander'. Sack face and a granule top surface and fire retardant chemistry. Torch, hot asphalt or cold adhell-n applied, fiberglass r membrane 2 •l i , poi thylene or sal* back face . , • •' ded top sur ce_ Frank Zuloa ga, RRC; Roofing duot Control rxamumer . .• • • POLYGLASS USA, INC. Product Elastoflcx VG Elastotiex VG FR. Xtn flex Xt reflex G Xtraflax O FR Elastoflex SA-1' FR Elastoflex SA -V FR Base Elastoflex SA -V FR Elastobase Polythetuu Al Polytherm TF (Tapered) Polytherm Composite Exterior Research & Design, LLC. J:/Y`1JYJOO:J Test Dimensions Specification 32' 10" x 3' 3 -3/8" ASTM D 6163 32' 10" x 3' 3 -3/8" ASTM 6163 32' 10" x 3' 6" 32' 10"x 3' 6" 32' 10" x 3' 6" 32' 6" x 3' 3 -3/8" 32'6 "x3'3 -3/8" 32' 6" x 3' 3 - 3/8" 65' 2" x 3' 3 -3/8" 1.2" to 4" thick a' x.4' or 8' 1.5" to 3.5" thick 4' x 4' or 8' 1.5" to 3.5" thick 4' x 4' or 8' EVIDENCE SUBMITTED: Test A,gencyAdentifier Factory Mutual Research Corporation Report No. J.I. 2W7A7.A.M J.1. 3001334 J.I. 3000857 J.Z. 3004091 #1 1757.12.00 -1 #1 1757.04.01 -1 ASTM D 5147 ASTM D 5147 ASTM D 5147 ASTMD6164 ASTM D 6163 ASTMD 6163 A STM D 4601 TAS 110 TAS 110 TAS 110 3 Dr - r1WU Acceptanc No.: 01 - 0529.01 Product Description Torch, hot asphalt or cold adhesive applied, • • • • fiberglass reinforced, SBS modified bitumen... membrane with a burn offpolyethyene onsandsd back face and a granule top ,t rfaoa, • • . • • Torch, hot asphalt or cold acibae' . fiberglass reinforced, SBS modified bitumen . membrane with a burn off polyabyyene oi:sanaed back face and a granule top eunfaae,and fire.reiardant • chemistry. • • .. Torch applied, polyester rc' uoforaad,, TPO modified bitumen membrane with a bium Oft polyethylene back face and a smooth top surfar. • Torch applied, polyester reifiWed TPO ranijfjed bitumen membrane with a burn off polyetfiyl te: back face and a granule top surface. Torch applied, polyester reinforced, TPO modified bitumen membrane with a burn off polyethylene back face and a granule top surface and fire retardant cheraistry. Self- adhered, polyester reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. Self - adhered, fiberglass reinforced, SBS modified bitumen membrane with a self- adhering back face and a smooth top surface. Self - adhered, fiberglass reinforced, SBS modified bitumen membrane with a self - adhering back face and a granule top surface. SBS modified asphalt coated fiberglass reinforced base sheet. PoIyisocyanurate insulation board. Tapered polyisocyanurate insulation board. Polyisocyanurate/periite composite insulation. Date 08.04.94 02.15.00 01.12.00 01.12.00 12.07.00 04.25.01 Zuloaga, RRC Roofing Product Control txaruuitL1' PAGE 05/25 • • • • • . • • • • • • • .�... y I • •-• %-• 11 • LY ' POLYGLASS USA, INC. APPROVED ASSEMBLIES: Deck Type 1L• Wood, Insulated, New Construction Deck Description; 19 /32" or greater plywood or wood 1 . • 6" o.c. P fastened with wood.screws fasteit0d.at` .. • • .. System Type A. All insulation layers are adhered, to a mechanics; • • • • • • • Membrane is subsequently adhered to insulation. •••• • • • 1 General and System Limitations 4,..,r_. • • • Fastening: Ply Sheet: JJYY JYJV VJ Acceptance No.: 01- 0529.o1 Insulation • Fastener Base Layer Fastening Fasteners...... Fastener Iyp Detail No. Per Board D . • One or more layers of the following: • Approved T •••••• • ype(s): • Any approved Polyisocyanurate • • • Minimum: 1" x 4' x 4' N/A N/A • • • N/A *WA• Note: AU insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within 'the EVT range and at a rate of 20-40 lbs /100 it Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second Layer of approved top layer insulation installed as the final membrane substrate, Composite insulation panels may be used as a top Layer placed with the polyisocyantu-ate side facing down. Insulation Fastener To La er Type ast F Fastening Fasteners Fastener Detail No. Per 'Board Density Approved Type(s): Fesco Board Minimum: %" x 2' x 4' N/A. N/A N/A N/A Approved Type(s): High Density Wood Fiber Minimum: %2" x 2' x 4' N/A N/A N/A N/A Approved " Type(s): Dena Deck Minimum: y1' x 4' x 8' N/A N/A N/A N/A Note: Apply top layer of insulation in a full hopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 Ibs/100 re. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only alkali be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanarate side facing down. Anchor Sheet: One ply of Elastobase Poly /Sand, Sand/Sand fastened to the deck as described below: Attach base sheet using Buildex Roofgrip Fasteners and Flat Bottom Plates spdeed 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggereil rows in the center of the sheet. (Optional) One ply of Elastobase, Modibase, Perna Ply No. 28, Elastoflex S6, Elastoflex V, Elastoflex V 2.5, Polybond or ply sheet adhered in full mopping of approved . range and at a rate of 20 -40 lbs. .0 sq. 4 Frank Zuloaga, RRC ,Roofing Product Coui,roi , V( L bb/ 25 . v..II 1 1 I LIIUV 11. LY POLYGLASS USA, INC. Membrane: Surfacing: JJ44:.14JOOJ bK5 - NM.) Acceptance No.: 01- 0529.0 One ply of Polyflex, Polflex G, Polyflex G Flt, Polybond, Polyborxd (3, Xtraflex, Xtraflex G or Xtraflex G FR torch applied or one ply of Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastosbield TS4 FR torch asphalt applied. • • • •••• • • • (Optional) Install one of the following to obtain required five•slacriflcatx "on:.. • 1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, ia4a.ltated coat of. approved asphalt at 60113s/sq. • 2. Karnak 97 Fibrated Aluminum, Asphalt Roof Coating or t4sbostos Free Aluminum Roof Coating at 1Y2 gal/sq. • 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gat/ • • • • • • • • • 4. Monsey Endure Aluminum Roof Coating, Weather ChecV be Pro -Grade • • Aluminum Roof Coating at P12 galfsq. •••• 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. : . • • ' •••• • 6. Fields E350 Heat Shield Aluminum Coating or F630 Heat Shield Fibored'. Aluminum Coating at 1V, gal /sq. • • • Maximum Design Pressure: -60 psf; (See general limitation #7.) 5 Frank Zuloaga, RRC Roofing Product Control Fxamin,et' NAGE 67/25 • • • • 1 •' • • • • • • • . 0 J/ 1 / / Lo,j0 11:L4 n44n4J13bb . POLXGLASS USA, INC. SRS -HWD Acceptance No.: 01-0529.01 Deck Type 1I: Wood, Insulated, New Construction Deck Description: 19/3," or greater plywood or wood plank, fastened with wood screws fastened at 6" o.c. PAGE 08/25 System T e A A(2): ()• All insulation layers are adhered, to a mechanically attached ttdchc sheep • Membrane is subsequently adhered to insulation. • • All General and System Limitations apply. .... • • • Insulation Fastener Fastening Fasteners •••• • a,�tel{er Base La er Type Detail No. Per Doan • • • • • ppe1t • One or more layers of the following: • Approved Type(s): �e( • • • • ): • Any approved Polyisocyanurat • • • • • • Minimum: l "x4'x4' N/A • • •••• • N/A N/A •••• • • 0 / , ‘ Note: All insulation shall be adhered to the anchor sheet in full mopping approved P of a roved hot asphalt • • • ,on within the EVT range and at a rate of 20-40 lbs/100 ft Please refer to Rootiwg Application Standard RAS 117 for insulation attachment Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocya�»urate side facing down. Insulation Fastener In a Ler , a Fastening Fasteners Fastener Detail No. Per Board Density Approved Type(s): Fesco Board Minimum: 3 A" x 2' x 4' N /A, N/A N/A N/A Approved Type(s): High Density Wood Fiber Minimum: ''A" x 2' x 4' N/A N/A N/A N/A Approved Type(s): Dens Deck Minimum: ' 'A" x 4' x 8' N/A N/A NIA, N/A Note: Apply top layer of insulation la a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs /100 ft Please refer to Roofing Application Standard RAS 117 for insulation attachment Insulation listed as Base Layer one shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanarate side facing d own. Anchor Sheet One ply of CertainTeed Glasbasc, Polyglass Base, Firestone MB Base, JM Perma- Ply #28, Tannko Glass Base or GAFGLAS #75 fastened to the deck as described below: Fastening #1: Attach base sheet using 11 g 8a. annular ring shank and 1 - 5/8" diameter tin cage spaced 8" o.c. in a 4" lap and 8" o.c. in two equally spaced staggered rows in the center of tb a sheet. (Meets --60 pf, See General Limitation #7) Fastening #2: Attach base sheet using Dekfast #14 with Hex Plates or Tru -Fast ;ID with MP Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. (Mew S2.Spsf, See G 6 Frank Zuloaga, RRC Roofwg Product Control Examiner . uJ/ 1 , / LrJOO 11:L4 7044047dd POLYGLASS USA, INC. Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: See fastening options above. 7 5 1'S -HWD • • ... • • • ... .. .. • • • .. .. • • • • • • • • ACe: plane No.: 01- 0329.01 (Optional) One ply of ElastobasepModibase, pern/ePly �d ,2$71asrollex S6, Elastoflex V, Elastoflex V 2.5 oir Ohe.oz+nnore plies tl f TyQe Y' 8g VI ply sheet adhered in full mopping of appre fed siphalt plie4 a ,the'EVT range and at a rate of 20 -40 lbs. /sq. One ply ofPolyflex, Polflex G, Pol, fl Gn t Po'1 ibond G, Xtraflex, Xtraflex G or Xtraflex G FR torch applidd Or ' . S6 G, Elastoflex S6 G FR, d ' S4 oielastoshQ i S4ex S6, Elastoflex or hot asphalt applied. R' hie FR torch or hot (Optional) Install one of the following to obtain required fire classification. 1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, in a flood coat of approved asphalt at 60 lbs/sq. 2 . Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at PA gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gal/sq. 4. Mousey Endure Aluminum Roof Coating, Weather Check or Pro -Grade Aluminum Roof Coating at 11/2 gal/sq. 5. Grundy al M8 Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 I-Icat Shield Fibered Aluminum Coating at 15% gal/sq, ilft.— Fraak Zuloaga, RRC Roofing Product Coritroj Ekamine- PAGE 09/25 100 / 1 / /'Lbbb • 11:Y4 . J544b4itiUb POLYGLASS USA, INC. . Aoecptance No.: 01- 0529.01 Deck Type 11I: Wood, Insulated, New Construrtipn. • • .. . " . • • • • • • Deck D • • • • • • • • • • • " 1 Description: 19 / 32 " or greater plywood or woad'plan$, fastend• eth wppfl stews fastened at 6" o.c. • System Type 13; Base layer of insulation mechanically f'stpne4, optJonal,top lover adhered with approved asphalt. • • • • • • • . . • All General and System Limitations apply. Base Sheet: Ply Sheet: 8 5K5 -HWD • • • •• • • • • • • • . • • • • •• • • • • 000 • • • • • • • 000 • • • • • • • • • • • • • 000 • • • Insulation Fastener Fastening Fasteners Fastener Base Layer Type Detail No. Per Board Density One or more layers of the following: Approved Type(s): E'NRG'y -2 or Polytberm Minimum: 1.5" x 4'x4' CF Dekfast #12, #14 or #15 With Hex Plates [3] 12 1:1.33 fie Tru -Fast HD with MP -3 Plates Note: Base layer shall be mechanically attached with fasteners and density described. Insulation parcels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard R.AS 117 for fastening details). Insulation Fastener Fastening Fasteners Fastener Top Layer Type Detail No. Per Board Density Approved Type(s): Fesco Board Minimum: W x 2' x 4' N/A NIA N/A N/A Approved Type(s): High Density Wood Fiber Minimum: '/" x 2' x 4' N/A N/A N/A N/A Note: Optional top layer of Insolation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs/1001 Please refer to Roofing Application Standard RA.S 117 for insulation attachment: Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. (Optional if using ply sheet in hot asphalt) One ply of Elastobase, Modibase, Perna Ply No. 28 or GAFGLAS 1175 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq. (Optional if using base sheet in hot asphalt) One ply of Polybond. Polyflcx oc Xtraflex torch applied or one ply of Elastobase, Modibase, Perna Ply No. 2b, Elastoflex S6, Elastoflex V or Elastoflex V 2,5 or one to more plies of Type EV or VI ply sheet adhered to the coverboad in a full mopping of approv''l asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Fran uloaga, RRC Roofing Product Coirtr'ol xamitior, PAGE 10/25 0:7/ 1 I / LUGO 11 : L4 'iO4454,titib FOLYGLASS USA, INC. Membrane: Surfacing: Maximurn Design Pressure: -60 psf; (See general limitation #7.) 9 SRS -HWD • ... • . .. • • . • • • • • ••• • . • • • ••• • • • • ... .. .. • • • • • • • oikeeptance No.: 01- 0529.01 One ply of Polytlex, Polflex G Pp G Fit, ISo7lybond, 1'olbond G, Xtraflcx, Xtraflex G or Xttaflex G FR tcc� a p2ie$ or one pt ofpl�stpfx S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastc►l11iold TS TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA -P FR or Elastoflex SA -V FR self- adhered. . . • • • •• ••• .. (Optional) Install one of the follow' oro 1. Gravel or slag at 400 Ibs /sq or 300 bs/t fe requited ' fire c lassification. approved asphalt at 60 lbs /sq. q ' �' fy, In a flood cost of 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1 V2 gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gal /sq. 4. Monsey Endure Aluminum Roof Coating, Weather Check or Pro- Grade Aluminum Roof Coating at 1% gal/sq. 5. Grundy al MB Aluminium Roof Coating at 1 -2 gat/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating at 1% gal /sq. Frank Zuloaga, RRC _ Roofing Product Cor.t..V. ami PAGE 11/25 uu, 1 1 i tuuo 11 : L4 '734434Jtiti POLYGLASS USA, INC. Surfacing: Maximum Design Pressure: -82.5 psf; (See General limitation #7.) 10 SRS -HWD • • • • : • • • • • •• • .. • • • . • . • • • ••• •• • • Deck Type 1I: Wood, Insulated, New Constrgct pn, • . • : : •• • • • • • • Deck Description: 19 / 32 " or greater plywood or wood 1 as • 6" o.c, . `p� f Sdrled • nth wood screws fastened at System Type C(1): All layers of insulation are mechanioalV stt §elielt4rdclfdec't Membrane is subsequently adhered to insulation.. • • • • • •• • • •• • All General and System Limitations apply, • • • • • •' • • •A.ee ptance No.: 01- 0529.01 Insulation Fastener Fastening Fasteners Layer Type Detail No. Fastener Per Board Density One or more layers of the following: Approved Type(s): ENRG'X 2, Polytherro Minimum: 1.5" x 4' x 4' SFS HD Znsulfixac with IFC/IW Plates Tru -Fast HD with IFC/IW Plates CF Dekfast #14 with IFC/IW Plates [3) 12 1:L33 t1 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind Load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: None Ply Sheet: One ply of Elastoflex SA- r self adhered. Membrane: One ply of Polyflex, kolflex G, Pol yflex G FR, Polybond, Polybond G, Xtraflex, Xtraflex G or Xtraflex G FR torch applied or one ply of Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastoshield TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA -P FR or Elastoflex SA -V FR self- adhered. (Optional) Install one of the following to obtain required Fire classification. 1. Gravel or slag at 400 Ibs/sq or 300 ibs/sq, respectively, in a flood coat of approved asphalt at 60 lbs /sq. 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1%2 gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gal/sq. 4. Monsey Endure Alurriinutn Roof Coating, Weather Check o_ Pro -Grade Aluminum Roof Coating at 1%2 gatfsq. 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shietrt Fibered Aluminum Coating at 1%2 gal/sq. r. Zuloaga, RRC Roofing Product Control Examiner PAGE 12/25 Vv ♦ 1i /LVVV 11 • LY POLYGLASS USA, INC. Deck Type 11: Deck Description: System Type C(2): Approved Type(s); Dens Deck Minimum: '/" x 4' x 8' N/A Base Sheet: Ply Sheet: Membrane: J:IYY:JY JOOJ 51t5 • • •.• • • •• •• • • • • • • • • .. • • • ... • • • • • • • • • ••• • • • • .•• •• • • • • .cc t tance No.: 01- 0529.01 Wood, Insulated, New Construction . • • • • • • • • • • • .. • • • • • • • • • • .. • • • •. t9 / 3z or greater plywood or wocd3,laii , fastehed.wlth woos straws 6 �� o.c. fastened at • All layers of insulation are methane ally gttashed 1p roAf decJ , Membrane is subsequently adhered to insulation. •• • • • • •• All General and System Limitations apply. One or more layers of the following: ]insulation Fastener Fastening Fasteners Base Layer Type Fastener Detail No. Per Board Density Approved Type(s): Any approved Folyisocyanurate Minitnwn: 1.5" x 4' x 4' N/A N/A N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation Fastener Top Layer Fastening Irasteners Fastener Type Detail No. Per Board Density Approved Type(s): High Density Wood Fiber Minimum: %, "x2'x4' N/A [3] 12 1:i.33{} 12 1:1.33 ft Note: All layer of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sip and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. (Optional if using ply sheet in hot asphalt) One ply of Elastobase, Modibase, Perma Ply No. 28 or GAFGLAS #75 adhered in a full plopping of approved asphalt applied within, the EVT range and at a rate of 20- 401bs. /sq. (Optional if using base sheet in hot asphalt) One ply of Polybond, Polyflex or Xtraflex torch applied or one ply of Elastobase, Modibase, Peima Ply No. 23, Elastoflex, S6, Elastoflex V or Elastoflex V 2.5 or one to more piiPs of Type IV or VI ply sheet adhered to the coverboad in a fill mopping of approved aspheh applied within the EVT range and at a rate of 20-40 lbs. /sq. One ply of Polyflex, Polflex G, Polyflex G FR, Polybond, Polybond G, XCattex, Xtraflex G or Xtraflex G FR torch applied or one ply of Elastoflex S 6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastosbueld T4 FR torch or hot asphalt applied or one ply of Elastoflex SA- ' ; adhered. SA -V FR se A 11 •• • • • r 31 . • • • • • ••. •• rank Zuloaga, RRC - - Roofing Product Control Examiner PAGE 13/25 POLYGLASS USA, INC. Surfacing; Maximum Design Pressure; J JYY JYJ V 0U -82.5 psf; (See General limitation #7.) 12 • • • • • 0 • • • • • •. •• • • • •• •• • • • • • • • • • • • • • • • • • • . • • • : A No.: 0 1- 05 • 0 00 • • (Optional) Install one of the 10116 to obtuz a • 1. Gravel or slag at 400 lbs/s4or•30Q bs/s • s CQaion. approved asphalt at 60 lbs/sq • • g' p�;C 4ively &fflood ood coat of 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1 % gfll/ • • • A • • 3. Kokem Products Sunguard Acrylic I tf7Cdatt,M at 1 gal/ j. 4. Monsey Endure Aluminum Roplroat ngAreetItcr•Cheek or Pro-Grade Aluminum Roof Coating at P/2 gal/sq. 5. Grundy al MD Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Alumiraun Coating or P630 Heat Shield Fibered Aluminum Coating at P/2 gal/sq. Frank Zuloaga, RRC Roofing Product Control Examiner PAGE 14/25 VJI 11I LVV 1 • L• Deck Type 11: Deck Description: System Type D(1): liasnlation Base Layer Base Sheet: Fastening: Ply Sheet: Membrane: J:JYYJY POLYGLASS USA, INC. Fastener Approved Type(s): Fesco Board Minimum: %" x 2' x 4' N/A Approved Typ High Density Wood Fiber NC/annum: Y2" x 2' x 4' N/A Approved Type(s): Dens Deck Minimum: '' /," x 4' x 8' N/A 13 •• • One or more layers of the following: Approved Type(s): Any approved Polyisoeyanurate Minimum; 1" x 4' x 4' N/A N/A Insulation Fastener Top Layer (Optional) Fastening �vpe Detail No. NIA N/A .•• • • • ••• All General and System Limitations apply. . . . • • • • • • • • • • • • • 0 • • • • • • • • • . • • • • • • .:. : : • Ac¢optance No. 01-0529.01 Wood, Insulated, New Coustruirign • . . : a • • . • • . • • • • . • • • • • • /32 or greater plywood or W ACIPlan i g fastened ' • 1, • a v�t l a weQd se�e'w fastened at All insulation layers are adhered, to a mechanically atti 13ed basc sheet. Membrane is subsequently adhered to insulating. • • • . . • • • . • Fastening Fasteners Detail No. I'er Board NIA Fasteners Per Board N/A N/A • . • Fastener Density One ply of Elastobase Poly /Sand, Sand/Sand fastened to the deck as described below: Frank Zuloaga, RRC Roofing Product Control Examiner N/A Fastener Density N/A N/A N/A NIA Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. N/A Attach base sheet using Buidex Roofgrip Fasteners and Flat Bottom Plates spaced 12" o.c. in a 4" lap and 12" o.e. in two equally spaced staggered rows in the center of the sheet (Optional) One ply of Polyflex, Polybond, or Xtraflex torch applied or one ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6, Elastoflex V, or Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20.49 lbs. /sq. One ply of Polyflex, Polflex 0, Polyflex G FR, Polybond, Poly'1 3.1.1 G, Xtraflex, Xtraflex Cr or Xtraflex G FR torch applied or one ply of Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield '1'S4 or Elastoshield TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA -P FR or Elastoflex SA- v FR self - adhered. PAGE 15/25 a POLXGLASS USA, INC. Surfacing: -.i Y Y JY JOOJ Maximum Design Prossure: -60 psf, (See General limitation #7.) 14 5K5 - HW!) • • ••• • • • ••• • • • • • • • • • • • • • • • • • • • • • • • • • • . . • • • • • • • • • • • .At eptince No.; O1- 0S29.01 (Optional) Install one of the f &lJo4 to obtai,r e i • • a t • • ap �fi>�classificatiou. l . Gravel or slag 400 dr 3(1d lbs/sci, revcctiv4Jy. in aklood coat of approved asphalt at 60 lbsyscr . •' •.. • • 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1'/ 3. Kokem Products Sunguard ,A.c3 S a Y� • •. .. • • • 4. Mousey Endure Aluminum Roof 4 'tot Co$ti_dg it 1 gal /sq. Aluminum Roof Coating at l 'gaV' ir>g,:VUea�lzar:Chg�l� or Pro-Grade 5. G rundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating at 1% gal /sq. uloaga, Roofing Product Control Examiner PAGE 16/25 J J Y Y JY JUOJ POLYGL4SS USA, INC. Deck Type u: Wood, Insulated, New Cottstruptipn, • • . • • • • • • • • • Deck Description: • • • • • • • •• • • • •• ption. 19 /33" or greater plywood or wood lank fastened • • 6" o.c. • • • • • • 'q'rth w�ptl sbrdws fastened at System Type D(2): All insulation layers are adhered, to a mc cal is subsequently • • e 'attached base sheer. Membrane e9 y adhered to insulation • • • * • All General and System Limitations apply. •• • • • • • ••• •• 15 • ••• • • •• • • • • • • • • • • ••• • • • ••• • • • ••• • •• • • • • • • :tom prance No.: 01- 0529.01 • Insolation Fastener $ase Layer Fa stening Fasteners Fastener n'Pe Detail No. Per Board Density One or more layers of the following: Approved Type(s): Any approved Polyisocyanurate Minimum: 1" x 4' x 4' N/A N/A N/A N /,A, Insulation Fastener ToL a'er ( O Fastening Fasteners Fastener Detail No_ Per Board Density Approved Type(s): Fesco Board Minimum: ' / x 2' x 4' N/A N/A N/A N /,A. Approved Type(s): High Density Wood Fiber Minimum: ' /z" x 2' x 4' NIA N/A N/A N/A Approved Type(s): Dens Deck Minimum: ''A" x 4' x 8' N/A N/A N/A NIA Note: All insulation shall have preli mainary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board baring no dimension greater than 8 ft. Base Sheet: One ply of CeztainTeed Glasbase, Polyglass Base, Firestone MB Base, JM Perma- Ply #28, Tamko Glass Base or GAFGLAS #75 fastened to the deck as described below: Fastening Attach base sheet using Dekfast #14 with Hex Plates or Tru- -Fast HD with MP-3 Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: (Optional) One ply of Polyflex, Polybond, or Xtraflex torch applied or one ply of Elastobase, Modibase, Perna Ply No. 28, Elastoflex S6, Elastoflex V, or Elastoflex V 2.5 or one or more plies of Type P1 or VI ply sheet adhered Ln frl'_ :hopping of approved asphalt applied within the EVT range and at a rate of 2 4� lbs. /sC. Membrane: One ply of Polyflex, Poi G, Polyflex G FR, Polybond, Polybond 0, Xtraflex, Xtraflex G or Xtraflex G FR torch applied or one ply of Elastofie:, 36, Elastoflex 36 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastoshield TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA -P FR or Elastoftex S 4 -V ' R self - adhered. , uloaga, RRC Roofing Product Control Examiner I L 11/25 POLYGLASS USA, INC. Surfacing: Maximum Design Pressure: -52.5 psi:; (See General limitation #7.) 16 • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • •• • • • • • • • • • • • • • "' • • • • r�c'ceptonco No.: 01- 0529.01 (Optional) Install one of "' • • • the followru� to of mitt • regtiirrd 9fir classification. 1. Gravel or slag at 400 Ibsts' o :3 00.1bs/sq; respeetively,in; � Mood coat of approved asphalt at 601bssq. • • ••• • • 2. Karnak 97 Pibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1 ' a 3. Kokem Products Sunguard A.ep�lie:abof C oa Ong at' 1 gai/.sq. 4. Mousey Endure Aluminum Roof t�,aXing t Veatterghw.le or Pro-Grade Aluminum Roof Coating at 11 gallsq' 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating at 1' 2 gaUsq. rank Zuloaga, RRC Roofing Product Control Examiner PAGE 18/25 VU/ 1 / / LUDO 11 . L4 7D4404.ibIiZ Surfacing: POLYGLASS USA, INC. Maximum Design Pressure: See fastening options above. 20 5K5 -HWU • ••• • • • ••• • •• • • • • •• •• • • • • • • • • • • • • • • • • • • • • • 1 1 • e4eeeptance No.: 01- 0529.01 • ••. • •• Deck Type .II: Wood, Non - Insulated. New CQn�trget:op • • ; • • • • • • 1 • • •• • • • • • • Deck Description: /82" or greater plywood or weed plank, faateacd•with wood strews fastened at 6" o.c. System Type E(4): Base sheet is mechanically attachedtoroo f d+eclq • • • • • • All General and System Limitations apply. • • • • • • • • • •• • • • • • ••• •• Base Sheet One ply of CertainTeed Glasbase, Polyglass Base, Firestone MB Base, JM Perma- Ply #28, Tatuko Glass Base or GAFGLAS #75 fastened to the deck as described below: Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1 -5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in two equally spaced staggered rows in the center of the sheet. (Meets --60 psf,, See General Limitation #7) Fastening #2: Attach base sheet using Deltfast #14 with Hex Plates or Tru -Fast HD with MP -3 Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. (Meets _52.5 psf, See General Limitation #7) Ply Sheet: (Optional) One ply of Elastobase, Modibase, Perma Ply No. 28, Elastoflex S6, Elastoflex V, Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs. /sq. Membrane: One ply of Polyflex, Polflex G, Pol ex G Xtraflex G or 3Gtraflcx G FR torch pplied or one ply of Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastoshield TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA-P FR or Elastoflex SA -V FR. self- adhered. (Optional) Install one of the following to obtain required fire classification. 1. Gravel or slag at 400 lbs/sq or 300 lbs/sq, respectively, in a flood coat of approved asphalt at 60 lbs/sq. 2. Karnak 97 Pibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1'/, gal/sq. 3. 'Coker]) Products Sunguard Acrylic Roof Coating at 1 gal/sq. 4. Monsey Endure Aluminum Roof Coating, Weather Check or Pro - Gracie Aluminum Roof Coating at 1 V gal/sq. 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq. 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibered • Aluminum Coating at 1'4 gal/sq. Frank Zuloaga, RRC Roofing Product Control Examint;r ' PAGE 22/25 LUDO 11; L4 34404..ItttIO POLYGLASS USA, INC. Surfacing: Maximum Design Pressure: -60 psf; (See General limitation #7.) 19 5K5 —HWU • • ••• •• •• • • • • • • • • • • • • • ••• • • • ••• • • • • • • • • ••• • • • • • • •Ace�ptance No.: 01- 0529.01 • • 0 • • • Deck Type 1!: Wood, Non - Insulated, New Co io pct' n • ..• .. Deck • • • • •• • • • • • Description: !9 /3 2 " or greater plywood or wood: f f • • o o • • 6" o c • •P enea`vvith WPM Cct$ws fastened at • • 000 • System Type E(3); Base sheet is mechanically attached to roof deck. All General and System Limitations apply, • • • • • .. .. • • • Base Sheet: One ply of Elastobase Poly /Sand, SandlSan fast td the Beck as described below: Fastening: Attach base sheet using Buidex Roofgrip Fasteners and Flat Bottom Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet (Optional) One of Polyflex, p Y Polyisond or Xtraflex torch applied or one ply of Elastobase, Modibase, Perrna Ply No. 28, Elastoflex S6, Elastoflex V, or Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in frill mopping of ' approved asphalt applied within the EVT rang and at a rate of 20 -40 lbs.sq_ Membrane: One ply of Polyflex, Polflex G, Polyflex G Xtraflex G or Xtraflex G FR torch applied or one ply of Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS4 or Elastoshield TS4 FR torch or hot asphalt applied or one ply of Elastoflex SA - FR or Elastoflex SA -V FR self- adhered. (Optional) Install one of the following to obtain required fire classification. 1. Gravel or slag at 4001bs /sq or 300 lbs/sq, respectively, in a flood coat of approved asphalt at 60 lbs/sq. 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1' /2 gal/sq. 3. Kokem Products Sunguard Acrylic Roof Coating at 1 gal/sq. 4. Money Endure Aluminum Roof Coating, Weather Check or Pro-Grade Aluminum Roof Coating at 1'A gal/sq. 5. Grundy al MB Aluminum Roof Coating at 1 -2 gal/sq_ 6. Fields F350 Heat Shield Aluminum Coating or F630 Heat Shield Fibeed Aluminum Coating at 1'4 gal/sq. Frank Zuloaga, RRC Roofing Product Contrcl 1✓xamu,ei PAGE 21/25 • r J JYY JY J IJ VJ POLYGLASS USA, INC. 23 9 This Acceptance contains pages 1 through 23. END OF THIS ACCEPTANCE • ••• • • • ••• • •• • • • •• •• • • • • • • • • • • • • • • • • • • • • Aateptaace No.: 01 - 0529.01 • ••• • • • • ••• NOTICE OF A.CCEPTANCg STAI4D Cblyte'I+x_Ql 1 Renewal of this Acceptance (approval) hall be considered after a renewal application has been F� (aPPr'o ) filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. • • • • • • • • • • • • • • • • • 2 Any and all approved products shall be permanent; tat 1&1 wwith Le:mraerzfaettret's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if a) There has been a change in the South Florida Building Code affecting the evaluation, of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) Ifthe Acceptance bolder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (tbxough the filing of a revision application with appropriate fee) and granted by this office, 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami - Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer, 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. l J 9 1 1. 0 0 0 0 0 Fran Zuloaga, Roofing Product Ccstitt4l`);xamnriete 0 W i ■ I . I I � 0 0 I -'Plat 'L5/ L5 0 • l . O . CID/ 1 // LC1120 11:G4 704404. 00 POLYGLASS USA, INC. 22 5K5 - hYWL • • • • • • • • • • • • 1 • • • • • • • • • • • • • • • • • • • • ••• • • • • • lc4tancc No.: 01. 0329.01 • • • ••• • •. WOOD DECK SYSTEM LIMITATIONS: • • • 1. A slip sheet is required with Ply 4 and Ply 6 when' used as a t'btthaftically fastened base or anchor sheet GENERAL LIMITATIONS: • • • • • • • ... .. . • • OOOOOO 1. Fire classification is not part of this acceptance, rifer to 'a d'trrrdnt'A'pproved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' waxinnun. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped_ If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation, Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allgw cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsisq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is bascd on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field - tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this limitation b specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall . conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) rank Zuloaga, RRC Roofing Product Control, 2,xamitier I L4/ z: