Loading...
294 NE 97 St (6)BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Lat Description Address of Building CONTRACTOR or BUILDER MIAMI SHORES VILLAGE, FLORIDA PERMIT N° 9906 Work to be performed under this Permit Date Contractor's License No. Subdi- vision Sq. Ft. Value of j 1 Amount of Project $ II Permit $ BY AUTHORITY This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. (INSPECTOR) BY__ In consideration of the issuance to Me of this permit : I agree to perform the work covered hereunder in compliance with all ordinances and regulation, pertaining thereto and in strict conformity with the plans, 4'rawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. BUILDING ELECTRICAL PLUMBING ROOFING Owner of Building Architect Contractor or Builder Legal Description Address of Building Lot 0 MIAMI SHORES VILLAGE. FLORIDA PERMIT N° 3689 DATF 195 Contractor's License No. Work to be performed under this Permit Bl. Subdi- vision Value of Project Amount of Permit $ . = This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the application herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings cr in the statements or specifications and that he assumes responsibility for work done by his agents, servants or employees. Signed: BY INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In ac- cepting this permit I assume responsibility for all done by either, myself, my agent, servant or employee. It • : CONTRACTOR OR BUILDER BY AUTHORITY u Date PERMIT APPLICATION FOR MIAMI SHORES VILLAGE i c � � 9 7 r7 x Job Address 0 Tax Folio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant ./6)s..0 e- 0 ��� Master Permit # 3 Fr 6 C) Owner's Address .c/'. Ale Q 7 /7f c J Phone 3()S-- 7 — G9 3 . 3 Contracting Co. 6ce)A/F I . Address Qualifier SS# - Phone State # Municipal # Competency # Ins. Co. Address Architect/Engineer Bonding Company Mortgagor Address Square Ft. c/3o Signature of owner and/or Condo President FEES: PERMIT i1 O. RADON 07/00S Date C.C.F. Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MEC CAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION 06/ / J /.D (r 77 // - (. % 7,) / 77 vj h ���' %'' lam (17 7 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Notary as to Owner and/or Condo President Date My Commission Expires: My Commission Expires: Estimated Cost (value),$ /000. Signature 9f Contractor or Owner- Builder Date Notary as to Contractor or Owner - Builder Date S D `` NOTARY t-• TOTAL DUE `t S APPROVED: 7 7 cl Zoning Buil Electrical Mechanical Plumbing Engineering 7 44 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 5 - 1 q- 4 Slob Address 2 9 ik- 9 7 51 Tax Folio Legal Description Historically Designated: Yes No V Owner/Lessee / Tenant Z. Q 'S Q r x(.1 e. ✓ c Q r Gt , Master Permit # a� " Owner's Address 2 ( •1 $ 'r" Phone Contracting Co. (`. 1 t - R. ob 4- t A--t., 1 f n-) L Address I ( he 0 O SW 'ham. 74 f '_ Qualifier Le. r , 1( u. e," SS# - Phone 7 _ 6 1 — 7 State # r , Municipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN WORK DESCRIPTION QE Pao ` \ A' — ` � 2 ' — v� lc c S is co 0-P Gv a_C kr. w I j> n 4. &ed r142/ R, f ��yN4� 5l s Square Ft Q 00 Estimated Cost (value) 1 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with al applicable laws regulating construction and zoning. Furthermore, I authorize the above -n ed contractor to do the work stated. Signature of owner and/or Condo President 1 414i C Date Notary as to Owner and/or Condo President ;Date • •• '• . za My Commission Expires: u f / r Z- I . s I.-. L? v . BS c El; ti !r sLrJ o . .:a FEES: PERMIT 3c RADON C.C.F. / NOTARY Notary as to Contrac My Commissipir) ENRY W. MACK COMMISSION A CC 400243 ` • - EXPIRES: November 25.1 , .. Bonded Thru No Public Undeivrrttats TOTAL DUE ,.. APPROVED: Zoning Building Electrical Mechanical Plumbing Engineering "e mac. Job Address: 'a.9 4 toe- 9 l v- Contractor Process No. 123.01 -166 9/94 Base Sheet: 1.) / A Fasteners: wit Ply Sheet(s): iv� Cap Sheet: N Q Asphalt: / A APPENDIX 'E° METRO -DADE UNIFORM BUILDING PERMIT SECTION II BUILT -UP APPLICATIONS AND MODIFIED BITUMEN SYSTEMS GENERAL: Type of Roof System Assembly to be Applied: Manufacturer of Roof System Assembly: Product Control Approval Number: System Number from Product Control Approval: Complete the following for all Roof System Assemblies: Built -Up Applications and Modified Bitumen Systems Page -1 Cho 44. - re 4-69% GAF 0- o ot q`-t : _. 1L) �_ \ - VS (Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System Guide Specification. ) ( Note: If a minimum roof system is to be applied, describe all components within the system and list the manufacturer of each component. DO NOT complete this section if system is Product Control Approved. ) ( Note: No insulation system is acceptable under the minimum roof category. ) Job Address: Contractor PERIMETER DETAIL #3: Gravel Stop or Drip Edge Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gravel Stop or Drip Edge. Insert leaders indicating Roofing Components names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. Gravel Stop/Drip Edge Gage: - Fastener Spacing: o.c. Clip Type: Clip Gage: 117 Deck Type: 1,Ay 6 714 _ el 41/' l., rD D Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gutters. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. Gutter Type: Gutter Gage: Fastener Spacing: Deck Type: PERIMETER DETAIL #4: Gutter Detail Built -Up Applications and Modified Bitumen Systems Page -6 Process No. lop A.. Job Address: Contractor PERIMETER DETAIL #5: 'Other' Detail Process No. Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may eicisit. Insert leaders indicating Roofing Component names, dimensions, thickesses, etc. Include fastener type and spacing used for wood - blocking attachment. 3x3 tMestft.1ehtt vAr - rbve.c W -15 71055 base b F4 �9 .e Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may exisit. Insert leaders indicating Roofing Component names, dimensions, thickesses, etc. Include fastener type and spacing used for wood - blocking attachment. PERIMETER DETAIL, #6: 'Other' Detail Built -Up Applications and Modified Bitumen Systems Page -7 Job Address: Contractor Process No. Insert Building and Parapet Heights. (If no Parapet exists, insert "N /A ") Also insert applicable information pertaining to the building below. (See ASCE 7 -88 Fact Sheet Attached) Exposure Category: Classification Category: At Hurricane Oceanline ?: Y N Basic Wind Speed at Building Location: 110 mph Building Condition based on % of Openings: GROUND LEVEL T t 0 feet feet BUILDING INFORMATION #1 Built -Up Applications and Modified Bitumen Systems Page -8 P* Job Address: Contractor PERIMETER DETAIL #1: Parapet Wall Detail Process No. Coping Cap Gage: Fastener Spacing: _ o.c. Clip Type: Clip Gage: Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Parapet Walls. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Areas to be Flashed. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. PERIMETER DETAIL. #2: Flashing Detail Built -Up Applications and Modified Bitumen Systems Page -5 Job Address: Contractor Process No. inches inches inches 4 FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND INSULATION LAYER(S). (Where Roofing Component not used in Roof System Assembly, fill in with "N /A ".) Surfacing: ( briefly describe, Top Ply: QrA.F. 8'dL -4.64 Bonding Material: Ply Sheet(s): Bonding Material: Fastener: 1 S L c 4 .-- (lfbare sheet met attached) Base Sheet: 41, - 7 5 Bonding Material: (if base it bonded) Fastener: '�A► f1A9l�P R I�— (if top insulat a aye mech. attached) Top Insulation Layer: ((/applicable) .•.. Bondp rning Material: (i /to layer bonded ) on Fastener: (if innlaton mech. attached) Insulation: Bonding Material: (d insulation bonded) de ____...■Vapor Retarder (ifapplicable) Primer. (1 /applicable) Built -Up Applications and Modified Bitumen Systems Page-4 DECK: Type: 6 7 In T w A A. l l Gage or Thickness: JJ Density. if concrete deck: Job Address: Reviewed Details ?: Notes: Contractor Process No. — FOR PLAN EXAMINER USE ONLY — Roof System Assembly Product Control Approved: If NO, note any deficiencies: Design Pressure Requirements: Field: psf Perimeter Areas: psf Corner Areas: psf Note any limitations: Y N Y N • Job Address: Top Ply: C % - r Oi c M► (Type and method oj attachment ) Surfacing: (Type, if applicable ) Flashing Materials: ( Type and method of attachment ) Contractor Process No. Built -Up Applications and Modified Bitumen Systems Page -10 Built -Up Applications and Modified Bitumen Systems Page -3 Job Address: ( Check* one of the following ) Recover If a recover, is the existing Roof System Assembly to be used as a bonding substrate ?: If YES, has an ASTM E907 test been carried out to confirm adhesion of the existing membrane to the substrate ?: Y N (If 'yes', attach ASTM E907 test report. ) Proposed Fastener: (Attach withdrawal resistance test report. ) Has the deck been examined for moisture ?: Y N (Provide data confirming compliance with Section 3401.9(c) . ) THE SYSTEM: All Roof System Assemblies in the Product Approval have a variety of options. Briefly describe the Roofing Components to be used in the Roof System Assembly and attach a copy of the manufacturer's published specification: Deck: ( Briefly describe ) Insulation: ( Type, size and method of attachment, if applicable ) ( Type and method of attachment ) Contractor Process No. Re -roof: New Construction Y N 1 b7 L `fun. rot.,/ Base Sheet or Ply: -!* 1 (4-100 1pep� Ply Sheet(s): ( Type and method of attachment ) Built -Up Applications and Modified Bitumen Systems Page -2 r Job Address: Reviewed Field Test Data ?: Notes: Additional Notes: Contractor Process No. Built -Up Applications and Modified Bitumen Systems Page-11 Y N Plan Examiner s co I - c r 1- oo fir. r..1 Cs c. , Job Address: ' i Rs R. - g ) SJ - Contractor Process No. 123.01.166 9/94 Base Sheet: 1J ! p Fasteners: iv? A Ply Sheet(s): 10) l:1 Cap Sheet: P3/ a Asphalt: iv/ A APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II BUILT -UP APPLICATIONS AND MODIFIED BITUMEN SYSTEMS GENERAL: Type of Roof System Assembly to be Applied: '\ d 4. ∎ €.eJ. 70 t-L Manufacturer of Roof System Assembly: IvACr 03 3o O b Product Control Approval Number: q System Number from Product Control Approval: YV .-\ ,\ - 1 1"'S (Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System Guide Specification. ) ( Note: If a minimum roof system is to be applied, describe all components within the system and list the manufacturer of each component. DO NOT complete this section if system is Product Control Approved. ) ( Note: No insulation system is acceptable under the minimum roof category. ) Complete the following for all Roof System Assemblies: Built -Up Applications and Modified Bitumen Systems Page -1 1 Materials .Cualantees Available S eclficatlan RUBEROID Llbe + % , w . N-1,1-MG �=--- . RUBEROtp 12, .fi 9 2.10 GAF Materials Corporation Stoop Roofing Asphalt A$) D- 312,r 1 11c )tr GAFGLAS 475 Base Sheet RUBEROID MOP (Granule Surfaced) r <; Approximat3.Wolght Per Square; . Total 14 -155 lbs. RU3EROSD® Specificati n 6H -M Substrcto- -y, inch niinimum plywood, gypsum structural wood fiber, lightweight insulating concrete. See "Lightweigh Insulating Concrete Decks," page 10. Slopes —Up to 1 inch per foot for lightweight ins lating concrete; up to 3 inches per foot for other decks. ilAnmema CORPORAnad General Recommendations presented on pages 17 -22 shall apply In addition to the following application recommondations. Application Recommendations 1. Lay ono ply of GAFGLAP d75 Base Shoot (or In the case of a fresh lightweight insulating concrete or gypsum deck whore STRATAVENTb (Vont Ply) for Nailablo Decks Is required), with a minimum 2 Inch We lap and not toss than 6 inch end Zaps. Nall along side lap of the base ply at Intervals not to exceed 9 lnchcs and stagger -nail down the centor of shat In two rows with nails sp °cod et 10 lneh Intervals In call row. 2. Starting at tho tow point of tho roof, fully onbed ono ply of RU®ERUIf MOP (Granule) In a nominal 25 pounds por 100 squaro feat (plus or minus 20 %) continuous cost of Steep Roofing Asphalt ASTM D -312 Type III or IV. The RUBEROID membrane must be positioned to provide 4 Inch side laps and 6 inch end laps. IL rq GAF Materials Corpora ion 1361 Alps Road Wayne, NJ 07470 Your application for Prod Chapter 8 of the Metro Construction, and comple Research Laboratory, lug Laboratories, Inc. and D Compliance Department t herein. The approval shall be val right to secure a product product or material fail to or suspend the use of suc the right to require testing enacted affecting this prod The expense of such testin PRODUCT NO. : ACCEPTANCE NO.: EXPIRES: APPROVED: `A . ® 05 kg ct Approval of GAF MMnterlr,Es Corporation Msgdlfied K?itumen Roof Systems under olitan Dade County Code governing the use of Alternate Materials and types of ely described in the plans, specifications and calculations as submitted by Construction ., Factory Mutual eseareh Corporation, South Florida Test Service, Underwriters nntech Engineering, Inc. has been recommended for acceptance by the Building Code be used in Dade County, Florida under the specific and standard conditions set forth d for a period of three years. The Building Code Compliance Department reserves the r material at any time for a jobsite or manufacturer plant for quality control testing. If erform in the approved manner, the Code Compliance Department may revoke, modify product or material immediately. The Building Code Compliance Department reserves f this product or material should any amendments to the South Florida Building Cede be c, or material. will be incurred by the Manufacturer. METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAGLI_R BUILDING WILDING CODE COMPLIANCE DE ^ADTMENT SUITE 1003 MET O-DADE FLAMER BUILDING 140 WEST FLAOLER. STREET MIAMI, FLORIDA 03130 • (365) 370.2001 FAX (3U 3a5.2110-0 ul Rodrlg. z Product Control Division Supervisor - PLEASE NOTE - THIS IS THE CO ERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS. BUILDING CODE COMMITTEE This application for Prod ct Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Department an approved by the Building Code Committee to be used in Co A lorida under the conditions set forth aboVe. arles Danger, P.E., Director Building Code Compliance Department Metropolitan Dade County Applicant: GAF Materials Corpo 1361 Alps Road Wayne, NJ 07470 Category: Sub - Category; Type: Sub -Type: GAF Materials Corporat years. • GAF .produces a wide products include both GAF offers two ply m modified specifications. GAF products are distrib South Florida area. GAF provides warranted can be obtained from Specification manual pub GAF roof system assemb Underwriters Laboratorie ASTM D 5147 test requ SYSTEMS PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL tion embrane Roofing System uilt -up Roofing odified Bitumen BS, APP Slataraihargristinn Product Control No.: _ 95aQ310.06 Approval Date: MAY 0 4 1995 Expiration Date: lg jiagri on has been manufacturing commercial roofing products for more than 100 ge of roof products for built -up roofing systems. The modified bitumen P and SBS products in smooth, granule and fire rated versions. In addition, d ified systems to meet the specification requirements for multilayer S ted through a wide network of roofing wholesale distributors throughout the systems over various insulated and non - insulated substrates, and can be found in the Ruberoid Modified Bitumen fished annually. ies have been extensively tested at Factory Mutual Research GAF modified bitumen membranes have been tested in ments. copies of which Application and Corporation and compliance with Contact: William J. Woodring 1 Director of Technical Services (201) 628 -3000 2 Raul Rodriguez Product Control No.: 95-0330.06 MateriRl Fibrous gl : ss Perlite Fiberboard Polyisocy: urate Expanded Nolystyrene (EPS) Polyisocya urate Composite Board Wood -60 psf Steel -75 psf Concrete -248 psf Lightweight Concre e -45 psf Poured Gypsum -45 psf Cl, nifcation Wood Class A Steel Class A Concrete Class A Lightweight Concre e Class A Poured Gypsum Class A Note: Fire classi cations aid ,,; aximum design pressures do not refe'e®ce all assemblies over deck types. Review system listings for design twessures and the Underwriters Laboratories Roofing terials Directory or other approved testing agency listing directory for Fire Classiflcati ns. 3 Raul Rodriguez Product Control No.: 9S-0330.06 Product Ruberoid Smooth Ruberoid® Torch Plus (Granule) Ruberoid® Torch Granule Ruberoid® Torch F Ruberoid® Mop Plus (Granule) Ruberoid i4 Torch 30 FR TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Dimension DimensionA Specification Description 1 sq. roll ASTM D 5147 Heavy duty, polyester reinforced, 87 lbs. asphalt modified bitumen membrane. % sq. roll 93 Ib. roll 1 sq. roll 102 lb. roll 3/4 sq. roll 90 lbs. 1 sq. roll 102 lbs. 1 sq. roll 103 lbs. Ruberoid® 30 1 sq. roll 92 lbs. 1 sq. roll 92 lbs. Ruberoid® Mop 170 FR 1 sq. roll 103 lbs. Product Control No.: 95 0330.06 ASTM D 5147 Heavy duty, polyester reinforced, asphalt modified bitumen membrane. ASTM D 5147 Asphalt impregnated, coated felt, surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Ruberoid® Mop FR 1 sq. roll 105 lbs. Ruberoido 20 1.5 sq. roll ASTM D 5147 SBS modified asphalt base sheet reinforce with a glass fiber mat. ASTM D 5147 Non -woven polyester mat coated with fire- retardant, polymer modified asphalt surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with fire retardant, polymer modified asphalt surfaced and surfaced with mineral granules. ASTM D 5147 Non -woven polyester mat coated with fire retardant polymer modified asphalt surfaced with min al g 4 Raul Rodriguez Product Aimen 'anc GAFGLAS® 3' x 36" Stratavent® (Vent "'ly) 69 Ib. roll for Nailable Decks. GAFGLAS® 3' x 36" Stratavent® (Vent '' ly) 69 lb. roll Perforated GAFGLAS Ply 6 GAFGLAS Ply 4 AlI<cr'l.A: 3° x 108' 75 lb. roll GAF Materials Corporation Asphal Concrete Primer 3'x 180' 45 lb. roll 3'x 180' 40 Ib. roll GAFGLAS® 3' x 36' Mineral Surfaced 76 Ib. roll Cap Sheet 5, 55 gallons GAF Materials 1, 5 gallons Corporation Fibered Aluminum GAF Materials Corporation WeatherCoat® Emulsion GAF Materials 1, 5 gallons Corporation Jetblak • 11 Weather Plastic Ce ent 5 gallons Test .Specification ASTM D 4897 D 3672 ASTM D 2824 Fibered aluminum coating. 5 Raul Rodriguez Product Control No.: 95- 0330.06 Product Description, Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. ASTM D 4897 Fiber glass base sheet impregnated and D 3672 coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type 1V asphalt impregnated glass felt with asphalt coating. ASTM D 4601 Asphalt impregnated and coated glass mat base sheet. ASTM D 3909 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. ASTM D 41 Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. ASTM 1227 Surface coating for smooth surfaced roofs. ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. Product Red Rosin Mu Ts Type X Gypsum Sturdi-Top al MB aluminum roof coating Grundy . Industrial Emulsion #14 Roofgrip Gripdek Fastener Premium Metal Plate . Standard Plastic Plate Karnak No. 169 Karnak 97 Barrier Board Plus Test Dinicirions Spacificatipn various Minimum # PA 114 12 Min. 32 ga. x various various PA 110 PA 121 3" squam 3" round PA 121 PA 114 various PA 110 Product Description Rosin paper for barrier generic layer on wood decks Corrosion resistant annular generic ring shank nails Corrosion resistant circular generic discs. Fire resistant rated gypsum generic Wood fiberboard Asphalt emulsion. • •.•.• • . • • •• ' Insulation fastener Product Control No.: 95-0330.06 Mantlfacturcr Georgia-Pacific Aluminum roof coatin Grundy Industries „Grundy,Industries PA 114 Insulation fastener steel, 1TW Buildex wood or concrete decks ITW Buildex PA 114 3" square galvalurne AZ55 ITV Buildex stress plate PA 114 Polyolefin plastic plate ITW Builciex ASTM D 2824 Aluminum roof coating Karnak Corp. PA 121 Roof coating Karnak 9 Polyisocyanurate foam / NRG arriers, Inc. wood fiber insulation Raul Rodriguez T"ctAP n Construction Rese Laboratory, Inc. Factory Mutual Research Corporatio South Florida Test Service Underwriters Laboratories, Inc. Dynatech Engineerin Inc Test Identifier #4818 J.I. OT4A 1.AM J.I. 1 V7AO.AM J.I. 1V8A4.AM J.I. 1R1A6.AM J.Y. OT2Q4.AM J.Y. 0Q6A6.AM J.I.2M0A4.AM J.I.3X3A2.AM J.I. 0Y9QS.AM J.I. 3X3A2.AM GAF -53 -X -915 R1306. , 3600.02.95 Test Reports 13 Test Name/Report Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Physical Properties Fire Classification Raul Rodriguez Product Control No.: 95- 0330.06 Date 07/10/87 08/26/92 07/16/92 06/28/93 11/15/91 10/17/91 07/16/91 03/21 /87 08/02/94 07/29/94 08/02/94 03/08/91 08/01/94 Wind Uplift, Small 02/02/95 Scala 0 Membrane Typ Deck Type 1: Deck Descriptio System Type E: All General End Base Sheet: Fastening: Note: Ply Sheet: Membrane: Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: SBS Wood, Non - insulated 19 42 " or greater plywood or wood plank decks Base sheet mechanically fastened. ystem Limitations apply. One ply of GAFGLAS® Ply 4, GAFGLASn PIy 64D, GAFGLAS® #75 or GAFGLAS Stratavent', (Vent Ply) for Nailable Decks mechanically fastened as described below: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 9" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c.. Ply 4 and Ply 6® applicntio require sheathing paper over tle wood deck before application of base sheet. (Optional) One, two or three plies of GAFGLAS Ply 4, GAFGLAS® Ply 60 or a single ply of Ruberoid® 20 in type III or IV asphalt at an application rate of 25 Ibisq. ± 15 %. -60 psf. 41 Raul Rodriguez Product Control No.: 95 0330.06 One ply of Ruberoid? Mop Granule,'Ruberoide? Mop Plus Granule or Ruberoid® Mop FR in type III or IV asphalt at an application rate of 25 lb. /sq. ± 15 %. (Optional) Install one of the following: I. GAFGLAS® Mineral Surface Cap Sheet in type III or IV asphalt at an application rate of 25 lb. /sq. ± 15 %. Class 'A'; see General Limitation #2. 3:12; see General Limitation #3. N- 1 -1 -MG, N -1 -1 -MGFR, N -1 -1 -MGFR, N -1 -2- 20/30, N- 1- 2- 20/30FR, N- 1 -1 -MGP Wood Deck System Limitations: 1. A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to wood plank deck. A red rosin sheet may also ue installed on plywood decks as an option. A red rosin sheet is required on all applications where Ply 4 or Ply 6' is used as an anchor sheet. 42 Raul Rodriguez Product Control No.: 9S- 0330.06 2. Pre - assembled 'Cap Nail' shall not be used for base sheet attachment. 3. Fasten anchor sheet 9" at the lap and 18" in two staggered rows centered on the sheet. Approved to -45 pot. 4. See PA 117 for extrapolation of data for higher design pressures. 0 General Linaitatio so Product Control No.: 95- 0330.06 1. !A11 asphalt shall comply with ASTM D 312 type III or type IV requirements. All roposed asphalt producers must be approved by the applicant. 2. Ire ratings are determined by a combination of slope, deck type and assembly. efer to current Underwriters Laboratories Roofing Materials Directory or other fire esting data listed by an approved listing laboratory agency. Fire ratings shall be in ompliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3. Maximum slope range shall vary for each system; consult current Underwriters aboratories Roofing Materials Directory and manufacturer's specifications for ompliance with design criteria for each project. 4. n overlay /recovery board insulation panel is required on all applications over !wed cell foam insulations when the base sheet is fully mopped. If no recovery and is used the base sheet may be applied using spot mopping with approved phalt, 12" diameter circles, 24" o.c.; or strip or spot mopped 8" ribbons in three ws, one at each sidelap and one down the center of the sheet allowing a continuous e a of ventilation. Encircling of the strips is not acceptable. A 6" break shall be laced every 12' in each ribbon to allow cross ventilation. Asphalt application of ether system shall be at a minimum rate of 12 lbs. /sq.. Note maximum design p ssure restrictions on spot attached systems. 5. Aln amendments to these provisions shall be in compliance with Sections 203 and 2 1 4 of the South Florida Building Code. 6. 11 work shall be performed by a Contractor licensed to do roofing work in Dade aunty. Contractor shall be familiar with the details and specifications published by e manufacturer. 7. 1 re-roofing applications, moisture content in an existing built -up roof must be in compliance with Section 3401.9(c) of the South Florida Building Code. 8. Prior to application, all existing roof surfaces used as a bonding substrate shall be tested for uplift resistance in compliance with Dade County Protocol PA 124 to the c: design pressure of the roof deck. 9. If required, any Factory Mutual Approved vapor barrier in conjunction with p • prietary or approved adhesives may be used prior to the application of the insulation layer. 10. P rimetee and corner areas shall have an increase in fastener density for both insulation and base sheet in compliance with Dade County Protocol PA 117 of the S . uth Florida Building Code. 11. AJ1 attachment and sizing of perimeter nailers and metal profile designs shall co form with Dade County Protocol PA 111 of the South Florida Buil g Cede. 168 Raul Rodriguez 12. 13. 14. Product Control No.: 95- 0330.06 Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section 11 Permit Appl ication. Roll good materials shall be stored in strict compliance with GAF Materials orporation requirements. onsult current Underwriters Laboratories Directory for the appropriate coating for ach roofing assembly to obtain the required fire rating. The assembly shall be nstalled in strict compliance with Chapter 3401.5 and 3401.6 of the South Florida uilding Code for maximum fire classification. 15. sphalt moppings shall be with applied with asphalt approved by the applicant and hall be approved in compliance with equiviscous temperature (EVT) methods of +sphalt application. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature nges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida uilding Code. 16. nsulatlon may be installed in multiple layers. The first layer shall be attached in ompliance.with Product Control Approval guidelines. All other layers shall be +dhered in a full mopping of approved asphalt at an application rate of 25 Ibs/sq. t 5 %, or mechanically attached using the fastening pattern of the top layer. Refer to anufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for orrect application procedures of insulation panels in approved asphalt or adhesive. 17. r re- assembled cap nails may only be used for termination of fully bonded surfaces uch as mechanical termination at wood blocking, head and side laps, and base ashing terminations. Cap nails shall not be used for the mechanical attachment of a ase sheet. Tin caps are required by the South Florida Building Code. 18. e submission of system specifications and details shall accompany the Section 11 : uilding Code Permit. This information is available in the publications listed in the ° . ystem Description' of this Product Control Approval. The submission of these ocuments, as well as the proper application and installation of all materials shall be t e sole responsibility of the contractor. 19. 11 standard panel sizes are acceptable for mechanical attachment. When applied in proved asphalt, panel size shall be 4' x 4' maximum. 20. astener spacing for base sheet attachment is based on a minimum withdrawal sistance value of 250 Ibf as tested in compliance with Dade County Protocol PA 105. If the fastener values as tested are below 250 Ibf a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken ���- -- m Dade County Protocol PA 105. Calculations shall be based on a rupture value (Qhe fastener stress plate pulling over the base ply) of not od: than 90 VA.. / 1 1 / Raul Rodriguez �`'� i t�,• 169 Product Control No.: 95- 0330.06 21. astener spacing for insulation attachment is based on a Minimum Characteristic once (F) of 300 lbf as tested in compliance with PA 105. If F' as field tested, is •elow 300 Ibf insulation attachment shall not be acceptable. 22. AF does not allow application of roof coatigs, other than a pour coat of asphalt and vel, over its granule surfaced Ruberoid® products. 23. n addition to the requirements of this Product Control Approval and the South lorida Building Code, applicator shall follow the manufacturer's specifications. 170 Raul Rodriguez ii.,) Application is hereby made for tl ing or other structure herein describ Shores Village, Florida, and all provi regulations of the Building Division plans and specifications must be kept Owner's Name and Address.__;! Registered Architect and /or Engineer Name and address of licensed contra Location and legal description of lot t Lot Block Street and Number where work is to t he done State work to be done and purpose I' building (by // _. New Building Rem To be constructed of Estimated Total cost of improvement Zone cubage required Distance to next nearest building Maximum live load to be borne by e. ch floor The undersigned applicant for th of labor under the Florida Workmen and has complied with the provisions in the work to be performed under t or notices as are required by the Act. permit, as are licensed by Miami Sh. Remarks and who, being by me first duly swo of the above described construction, therein by him stated are true Permit No Date Disapproved _____________ (Signed) Chairman Member Member . Council Approved IAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT pat Building Inspq}ctor e approval of the detailed statement of the plans and specifications herewith submitted for the build- '. This application is made in compliance and conformity with the Building Ordinance of Miami ions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and ` Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved at building during progress of the work. 1 Subdivision vG!i tor _!/,‘ be built on: floors) Date___, /l.( « Street /Lf _ ,r Read, Sworn to and Subscribed before me. 2 - r > )� /) n ) ( ' c. U � ✓ � L. , a f or no o t h er purpose. deling Addition Repairs � No. of Stories Kind of foundation._ ___ Roof Covering k // ' ' $ z� ? • ✓ Amount of Permit $ _Plan Cubage Size of Building Lot I hereby submit all the plans an specifications for said building. All notices with reference to the building and its construction may be sent to s building permit does hereby certify that he understands and accepts his obligations as an employer s Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, thereof, and will require similar compliance from all contractors or sub - contractors employed by him is permit; and will post or cause to be posted for inspection on the site of the work such public notice The undersigned agrees to employ only such subcontractors, on work to be performed under this ) res Village. (Signed) - % - STATE OF FLORIDA, COUNTY OF DADE. j ss. Before me, the undersigned auth.rity, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared to me well known, n, upon oath deposes and says that he is the hat he has carefully read the foregoing application, and that he did sign the same, and that all facts Notary Public, State of Florida My Commission Expires LANNING BOARD DATE Member Member Member Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and /or workmanship. Date Legal Description (31 'essee / Tenant Owner's Address Contracting Co. Qualifier Square Ft WARNING TO OWNER: YOU RESULT IN YOUR PAYING TWI CONSULT WITH YOUR LENDE Application is hereby made to obta certify that all work will be perfo p ermits are required for ELECTRIC OWNER'S AFFIDAVIT: I certify laws regulating construction and zo Signature of owner and/or Condo Pr APPROVED: Zoning Mechanical FEES: PERMIT , '7 ON PERMI; APPLICATION FOR MIAMI SHORES VILLAGE Job Address State # C .. 6.//2 Municipal # Architect/Engineer Bonding Company Mortgagor O . VP" t/ JOSE ANTONI 2 if n COMMISSION t q �, - Q CC55 - Fr a4-?:" j MY COMMIES OF F O JUNE Notary as to Owner and/or Condo Pr My Commission E fires: y P OFFICIAL NOTARY SEAL Tax Folio Address Historically Designated: Yes No , SS# - Competency # Address Address Address ti 13 3? A Master Permit # c;- Phone Ins. Co. Permit Type (circle one): BUILD G ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE WORK DESCRIPTION C� �� t - 7 -Ce Estimated Cost (value) _ rC Phone (if 2/ SIGN sident Signature of Contractor or 0 er -B UST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY E FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I d to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate , PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. at all the foregoing information is accurate and that all work will be done in compliance with all applicable g. Furthermore, I authorize the above -named contractor to do the work stated. J LOPEZ NUMBER 631 2Cci , Buildin Date My Commission Expires: l`LAi /% No as to Contractor o • ' er- Builder Date Date 0 ‘P s ly p" G T6'�i ' � OSEAN O O 2 `� i �t n COMMISSION NUMBER a /kg` PP•s •r CC558631 4,14- e� MY COMMISSION EXPIRES OF FA JUNE 2,2000 D 73 C.C.F. a 9t, NOTARY BOM5 TOTAL DUE *" 1 • f lectrical .astral � Plumbing Engineering Contractor's Name: 0 (Low Slap Application) 0 (Aspin It/Fiberglass Shingles) Ft. 0 New Roof Appendix ”E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 11.QQFSAI'EGORY 0 (Nail-On Tile) (Mortar O ( Metal Roofs1Wood Shingles & Shakes) )itOOP TYPE Re 0 Recovering 0 Repair 0 Maintenance Flat Roof Area (ft') Sloped Roof Area (ft') Total (ft') Master Permit No. Exposure category (per ASCE 7-88) _C. Building Classification category (per ASCE 7-88 table 1) Deck type:_ Fastener Type: ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) JITACHMENT ■••=11.1., Job Address: r 0 (Other) ROOF PLAN esive Set Tile) Deck type: rik /'t/ ?,4Q. RSA/ 144. 3 3' /C. / Ridge Ventilation? MEAN HEIGHT Ait z Under laymenr Insulation: D E T A I L 3 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 12" ROOF SLOPE SLOPED S YSTEM DESCRIPTION Fastener type & spacing: Cap Sheet: Roof Covering: Page -2 Drip edge: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance - Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals TILE CALCULATIONS (Pmaxl: ni 3 x X (Aerodynamic Multiplier): t ' ) - M . 0 0 J = M J4. ' PCA: 8' 61 (Pmax2: f' (Aerodynamic Multiplier): O/ ) - M t , S ^ = M ZZS ?PCA: ,964/ (Pmax3: /04fx X (Aerodynamic Multiplier): �/ ) - M 6,4T = M ? !3 PCA: ff1 / rarIN .d p /c!& '° pee `/)ez y ) /60 '° 06/16.'98 TtE 10:4 7 FAX 5 » 1 338 5391 METRO naoi: June 11. 1998 Mr. Reese H. Moody Technical Services Manag: r 135 NW 20 Street Boca Raton, Fl 33431 R 97- 1124.16 Monier Lifetile LLC villa, Capri, & Roll Tiles Sincerely, Raul Rodriguez • Product Control Supervisor cc C. Danger PE, Direct .r MONIER LIFETILE 44-> COMA CAST LJ U01 METROPOLITAN DADE COUNTY, Y, FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO -DADE FLAGLER DLILDTNG 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 - 1563 (305) 375 -2901 FAX (305) 375 - 2903 PRODUCT CONTROL DIVISION (305)375.2902 FAX (305) 372-6339 Dear Mr. Moody: This is to inform you that a Notice of Proposed Action referenced above for the renewal of NOA 95- 0316.04 has been issued d sent to the Building Code and Product Review Committee for their final review on June 5, 1998. a expect that their review will be completed within 20 days, at which time the Notice of Acceptance OA) will be issued. By means of this letter we are extending the expiration of the above listed NOA's from the original expiration date of June 1 ,1998 to July 31, 1998 to cover the committees final review time. Please attach a copy of this letter to the existing NOA's at time of pennitting. This letter expires July 31, 1998. We hope this addresses y• ur concerns, should you require any further information on this matter please feel free to contact this o ' ce. F: TRODCNfL\PCLCTTERIRESPO ' SLIINDUSTRY1 98MonierLifedic06.doc Internet mail address: pos astera@buildingcodeonliue.com • Homepage: http :I /www.buildingtodeanline,com 1' • 1 PRODUCT CONTROL Lifetile Corporation 200 Story Road Lake Wales FL Your application for Product Nail On Mortar or Adhesive under Chapter 8 of the Metro Types of Construction, and co Redland Technologies, The Engineering has been recommended for ac County, Florida under the spe on page 3. This application for Product Code Compliance Departme County, Florida under the c Approvcd:06/14 /95 NOTICE OF ACCEPTANCE 33859 -0632 Acceptance No.:95- 0316.04 Expires:06 /14/98 _ pproval of: apri Tile olitan Dade County Code governing the use of Alternate Materials and pletely described in the plans, specifications and calculations as submitted by enter for Applied Engineering, Inc., and Atlanta Testing & eptance by the Building Code Compliance office to be used in Dade ific conditions set forth on pages 2 et. seq. and the Standard Conditions , This approval shall not be val d after the expiration date stated below. The Office of Code Compliance reserves the right to secure th' product or material at anytime from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Code Compliance Office may revo e, modify, or suspend the use of such product or material immediately. The applicant shall evaluate thi product or material should any ammendments to the South Florida Building Code be enacted affecting thi product or material. The Building Code Compliance Office reserves the the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to met the requirements of the South Florida Building Code. The expense of such testing will be incurred y the manufacturer. (Revises No.: 94- 0914.23) METROPOLITAN DADE COUNTY. FLORIDA METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 • (305) 375 -2901 FAX (305) 375 -2908 PRODUCT CONTROL SECTION (305) 375 -2902 FAX (305) 372 -6339 Raul Rodr Product Control Supervisor THIS IS THE COVER HEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL. CONDITIONS BUILDING CODE COMMITTEE Approval has been reviewed by the Metropolitan Dade County Building t and approved by the Building Code Committee to be used in Dade nditions set forth above. s anger, ' . Director Building Code Compliance Dt Metropolitan Dade County Applicant: Lifctile 200 Story Road Lake Wales, FL 33859 Cate orv: Su b - Category: IXD.C: Sub - Type:: PRODU Prepared R Tile Nail -on/M Concrete Lifetile is a member of California, Texas and Florida. adhesive set applications. All til tile surface finished with a cem 'cured' prior to shipping to ach Lifetile's "Capri profiles. • Lifetile sells tile systems pieces used for rake hip, ridge hi systems. flashing systems and profiles and form a part of this P Lifetile's "Capri*' Tile" Code requirements for concrete rouf slope for :.ifetile's "Capri "Profile Drawing" section in thi Tile" tile profile has been test any consideration for installati calculations is noted in Tables 1 CONTROL•NOTICE OF ACCEPTANCE OOFING SYSTEM APPROVAL ofing rtar Set/Adhesive Set System Description Contact: Dave Faulkner Technical Services Manager 200 Story Road P.O. Box 632 Lake Wales, FL 33859-632 (813) 676 - 9405 Product Control No.: Approval Date: Expiration Date: 9i- 0316.04 JUN 1 4 1995 JUN 1 4 1998 e Boral Group and is a national producer of extruded concrete tile in ifetile manufacturers concrete roof tile for nail -on, mortar set and is extruded under high pressure in individual molds with the exposed ntitious material colored with synthetic oxide additives. All tile is eve maximum strength. This Product Control Approval relates to Refer to apnropriate Product Control Approvals for other the through local, wholesale distribution. All profiles have matching trim p, and valley terminations. Tile system accessories such as ventilation b'rdstops are also available. These accessories arc manufactured for all duct Control Approval. roof tile has been tested in compliance with the South Florida Building nail - on, mortar set and adhesive set tilt applications. The minimum Tile" nail -on, mortar set or adhesive set tiles shall be 2 ":12 ". See the approval for the "Capri' Tile" profile drawing. The Lifctile "Capri" for both wind characteristics and static uplift performance. therefore. n shall be done as a 'Moment Based System'. Data for attachment through 4 of this approval. Product Capri" Tile Trim Pieces T DE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT v 1= 17" w = 13'! '' " thick 1= varies w = varies rying thickness Product Control No.: os -d ; 1 6. Test Product $pecifcationt Description PA 113 Low profile. interlocking. high pressure extruded concrete roof tile equipped with two nail holes and double roller ribs. For direct deck or battened nail -on. mortar or adhesive set applications. PA 112 Accessory trim. concrete roof pieces for use at hips, rakes. ridges and valley terminations. Manufactured for each tile profile. 1 3 Produst #30 Felt #43 Coated Base N/ Sheet R.ineral Surface Cap Sheet Lenzingtex -ZB 140 Underiayment Rainproof 11 Ice and Water Shield t1 lopping Asphalt Flashing Cement TRADE NA N/ ES OF PRODUCTS MANUFACTURED OTHERS Test Specifications ASTM D 2 26 type 11 ASTM D 2626 N ASTM D 249 59" x 64' roll 22 l shall 30" x 75' roll 36" 75' roll 60" 75' roll 36" 75' roll N/A N/A PA 104 PA 104 PA 103 ASTM D 312 type 111 or IV ASTM D 4586 Product Control No.: 9s-0116.04 Product Deserintion Saturated organic felt to be used as a nailed anchor sheet. Saturated and coated organic base sheet for single or double ply underlayment. Mineral surfaced asphalt roll roofing for use as a top ply in a double ply underlayment system. Single ply. nail -on underlayment. Single ply. nail -on underlayment with 2" self - adhering top edge. Self - adhering underlayment for use as a top ply in a two ply underlayment system with approved #30 or #43 as the base laver. Asphalt for bonding a mineral surface cap to a mech. attached base sheet in a double ply undcrlavmcnt system. Cut back. asphalt based. asbestos free. fiber reinforced. trowel :trade cement for repair and flashing applications. - Manufacturer generic generic generic Lenzing Performance. lnc. PCA #94- 0527.05 Protect -O -Wrap. Inc. PCA #94- 0714.01 W.R. Grace Co. PCA #92-1116.01 zencric _•cncric Product Asphalt Primer Roofing Nails min. 3 Tin Caps Wood I3attcns Tile Nails Tile Screws Roof Tile Monar • ("TileTiteT " ") ,- Roof Tile Mortar ' ( "Quikrctc® Roof Tile Mortar #1140") i m� t. 32 ga. mi 1'!," o.d. m x. 2" o.d. min. with min. Wood Preservers Salt pressure treated m n. 1" x 4" institute LP - 2 or decay resistant lumber battens Via. with " head " x 4" for use ertical battens or 1 " x 2" for use alone N/A PA 114 Appendix E PA 114 Appendix E • PA 123 Product Control No.: 9s -0 ; 16 n4 • Test Product 5neciftcations Dcscrintion Manufa cturer ASTM D 41 Cut back, asphalt generic based coating used to facilitate bonding of dissimilar materials. Annular ring shank, hot dipped. electro or mechanically e.aly. roofing nails for use in underlayment attachment. Corrosion resistant circular disc for use in underlayment attachment Generic mi . 3d x 2'4" or PA 114 Corrosion resistant. �_encric in. 10d x 3" Appendix E screw or smooth shank nails. x 2' /_" long PA 114 Corrosion resistant. gcncric O. 35" head dia. Appendix E coated. v.uarc drive, 0.131" shank dia. galvanized. coarse 0.115" screw thread_ thread wood screws diameter N/A PA 123 Prepared mortar mix Bermuda Roof designed for mortar Company. Inc. set roof tilt PCA #94- 0614.01 applications. Prepared mortar mix Quikrctc Constructio dcsiencd for mortar Products sct roof tile PCA #94- 080S.0I applications. generic generic Product Roof Tile Mortar ( "BONSAL® Roof Tile Mortar Mix ") Valley Flashing Drip Edge N/A Roof Tile Adhesive ( "Polypro® AH 160 ") Hurricrne Clip & PA 114 Corrosion resistant Fasteners min. h width Appendix E bronze, aluminum, min. 0.0.0" thick stainless steel, galvanized steel or plastic attachment min. 8 •! x 1V." clips for supplemental tile attachment. Clips are installed with corrosion resistant roofing nails compatible with the clip. min.26 ga. min. 16" width min 26 ga. min. 2" ace flange min. 2" eck flange • Test Snecipcations PA 123 Product Descrintion Prepared mortar mix designed 'for mortar set roof tile applications. See PCA Two component Polyfoam Products. polyurethane adhesive Inc. designed for adhesive PCA #94- 0401.01 set roof tile applications. ASTM A 525 Galvanized steel valley flashing PA 111 Galvanized steel drip edge Product Control No.: 95-0116 04 Manufacturer W.R. Bonsai Co. PCA #94- 0623.03 generic 2encric _Zcncric Test A'enc\ Redland Technologies Redland Technologies The Center for Applied Engineering, inc. The Center for Applied Enigneering, Inc. The Center for Applie En_ineering, Inc. The Center for Applie Engineering, Inc. The Center for Appli d Engineering. Inc. The Center for Appi ed En_ ineering. Inc. The Center for App led En_inecring. Inc. The Center for Ap Enszineering. Inc. lied TEST REPORTS Test Identifier 7161 -03 Appendix Ill 7161 -03 Appendix 111 94 -084 94-060B 25- 7094 -1 25- 7094 -7 25- 7094 -4 25-71S3-1 25- 7153 -2 25- 7214 -2 Test Name /Renart Static Uplift Testing PA 102 Static Uplift Testing PA 102(A) Static Uplift Testing PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails. Direct Deck. 5/8" plywood) Static Uplift Testing PA 102 • (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Hcadlap. Nails. Dircct Deck, 15/32" plywood) Static Uplift Testing PA 102 (2 Quik-Drivc Screws. Direct Dcck) Static Uplift Testing PA 102 (2 Quik - Drive Screws, Battens) Static Uplift Testing PA 102 (1 Quik -Drive Screw. Direct Deck) Product Control No.: nc -n 16 (14 Date Dec. 1991 Dec. 1991 May 1994 March. 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 March. 1995 Test A.7encv The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering Test identifier 25 -7214-6 7161 -03 Appendix II Letter Dated Aug. 1, 1994 P0631 -01 PO402 Project No. 307025 Test #MDC -76 RI.894 R2.894 R3.894 Product Control No.: c)8 - 16 ns Test Name/Report Aare Static Uplift Testing March, 1995 PA 102 (1 Quik -Drive Screw, Barrens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of smooth vs. screw shank nails Wind Driven Rain PA 100 Physical Propcnics PA 112 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Deck Type: Vood, Non - insulated Deck Description: ew Construction 9 / 3 ," or greater plywood or wood plank. SYSTEM A: Slope Range: Underlayment: Vertical Battens: Horizontal Battens: Roofing Tilc: Comments: Counter -Batten Application SYSTEMS Product Control No.: ns_r-1 n.t 2 ":1 to 7 ":12" Note: Counter- Battens, as noted below, are required for scope ranee 2 ":12" to less than 4 ":12" and are optional for slopes of 4 ":12" to 7 ":12 ". For slopes exceeding 7 " :12 ", refer to System C. Install underlayment system in compliance with Dade County Application Standard PA 118. Install vertical battens in compliance with Dade County Application Standard PA 118 Install horizontal battens in compliance with 'Dade County Application Standard PA 118. Install tile in compliance witli Dade County Application Standard PA I 18. (See "Data for Attachment Calculations" included in this Approval.) 1. For rc -roof applications, " /, :" plywood is an acceptable substrate. 9 SYSTEMS (CONTINUED) Deck Type: Woo', Non- insulated Deck Description: New construction 1° / or greater plywood or wood plant:. SYSTEM B: Dire, t Deck Application Product Control No.: Q. n.t Slope Range: 4 "::2" to 7 ":I2" Not : System B is only acceptable in this slope range. For slopes less than 4":12", refer to System A. For slopes in excess of 7 ":I2 ", refer to System C. Underlayment: Roofing Tile: Comments: Ins 11 underlayment system in compliance with Dade County Application Stagy dard PA 118. Ins 11 tile in compliance with Dade County Application Standard PA 118. (S "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, " /, :" plywood is an acceptable substrate. 10 SYSTEMS (CONTINUED) Product Control No.: Deck Type: W,.od, Non - insulated Deck Description: N construction ' /, : " or greater plywood or wood plank. SYSTEM C: Horizontal Batten Application Slope Range: 4' :12" or greater Note: Horizontal battens, as noted below, arc required for slopes in excess of 7 ":12" and are optional for slopes of 4":12" to 7 For slopes less than 4 ":12 ", refer to System A. Underlayment: I stall underlayment system in compliance with Dade County Application tandard PA 119. Horizontal Battens: Install horizontal battens in compliance with Dade County Application tandard PA 119. Roofing Tile: nstall tile in compliance with Dade County Application Standard PA 119. See "Data for Attachment Calculations" included id-this Approval.) Comments: 1. For re -roof applications. " /,:" plywood is an acceptable substrate. 11 7 ��/ v Deck Type: Deck Description: SYSTEM D: Slope Range: linderlayment: Roofing Tile: Comments: 2 ":12" Note: SYSTEMS (CONTINUED) Wood, Non - insulated New c nstruction 1° / 32 " or greater plywood or wood plank. Morta or Adhesive Set Application Product Control No.: 9s-n1 A n4 to 7 " :12" System D is only acceptable in this slope range. For slopes in excess of7 ":12 ", refer to System C. Instal underlayment system in compliance with Dade County Application Stan PA 120. (See System Limitation #5.) Insta I tile in compliance with Dade County Application Standard PA 120. (See Data for Attachment Calculations" included in this Approval.) 1. F r re -roof applications, t ' /„" plywood is an acceptable substrate. 1: The standard minimum of pitch for Lifetile's "Capri'"' Tile ", low profile tile shall comply with Dade County Applicati n Standards PA 118, PA 119 or PA 120, depending on the method of installation. SYSTEM LIMITATIONS Product Control No.: QS -n' 16 n1 For nail-on applicatio , fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the p formed holes in the tile. 3. System installation sha Control Approval. The expressed as a mome compliance with Dade has been tested for bo calculations for install Based System'. I be in compliance with the system specifications outlined in this Product ;method of attachment utilized shall provide sufficient attachment resistance t to meet or exceed the required moment of resistance determined in ounty Protocol PA 115 or PA 127. The Lifetile "CapriT"' Tile" tile profile wind characteristics and static uplift performance, therefore. attachment tion in compliance with PA 115 or PA 127 shall be done as a 'Moment 4. For mortar or adhes e set tile applications, a field static uplift test by a Dade County accredited testing agency, in com . fiance with Dade County Protocol PA 106, shall be performed. 5. For mortar set tile a plications, 30/90 hot mopped underlayment applications may be installed perpendicular to the ro • f pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear e imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roo Pcrmit, a copy of L Approval and a cop proposed tile applicat S. The applicant shall quality control in co taken shall be in com 9. Any amendments to Florida Building Co ng *permits shall include a completed Section 11 of the Uniform Building fetile's current specifications and details, a copy of this Product Control of the Product Control Approval of any Roofing Component used in the on. Reference shall be made to appropriate data for the required fire rating. twin the services of a Dade County certified testing laboratory to maintain pliance with the South Florida Building Code and related protocols. Samples fiance with Dade County Protocol PA 112. Appendix 'A'. hese provisions shall be in compliance with Sections 203 and 204 of the South e. 13 1� Table 3: dttachment Resistance Expressed as a Moment - M, (ft -Ibf) from PA 102 and PA 102(A) Testing' Tile Profile Tile . Application Approved Nails Approved Screws 2 s crews Approved Field Clip With: Approved Eave Clip With: 1 nail 2 nails 1 screw 1 nail 2 nails 1 nail 2 nails Capri" Tile Batten 4.10 7.10 22.90 49.10 24.20 34.80 22.10 32.20 Direct Deck 11.80 21.90 25.80 47.10 24.30 35.50 19.00 I 31.90 Tabl 2: Restoring Moments due to Gravity - M (ft-lbf) from PA 102 Testing Tile Profile 3 ":12" 4 ":12" 5 ":12" 6 ":12" 7 ":12" or greater Battens Dir ct D ck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens ( Direct I Deck Capri Tile 5.92 6. 0 5.82 6.69 5.70 6.55 5.56 6.39 5.41 N/A Data noted in Table 3 is for installation wifh a 3" tile headlap. 2 Approved screws are s noted in the Trade Names of Products Manufactured By Others' and 'Profile Drawings' sections of is Approval. Clips on eave tile are not required for this attachment configuration unless the Required Mo ent of Resistance exceeds the values noted above. DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 9: - 0. 16.04 Table 1: Aerodynamic Multipliers - k (ft') from PA 108 Testing Tile Profile 1. (ft') Batten Application X (ft Direct Deck Application Capri" Tile 0.27 0.29 Data noted in Table 3 is for installation wifh a 3" tile headlap. 2 Approved screws are s noted in the Trade Names of Products Manufactured By Others' and 'Profile Drawings' sections of is Approval. Clips on eave tile are not required for this attachment configuration unless the Required Mo ent of Resistance exceeds the values noted above. DATA FOR ATTACHMENT CALCULATIONS 14 Product Control No.: 9: - 0. 16.04 Table 3 -A: R ttachment Resistance Expressed as a Moment - M, (ft-lbf) from PA 102 Testing Tile Profile Tile Application Two (2) 10d x 3" long nails' Capri' Tile Direct Deck New Construction (min. "4 2 ' plywood) 67.50 Direct Deck Recover/Reroof (min. " !u plywood) 43.00 Battens New Construction 50.90 DATA FOR ATTACHMENT CALCULATIONS (CONTINUED) Product Control No.: Q-(6 (11 Tile instaltatibn with a 4' headlap using two (2) Approved 10d x 3 tong polymer coated. corrosion re istant, ring shank nails installed in manufactured holes located 2W from the head of he tile. Clips on eave tile are not required for this attachment configuration unless the equired Moment of Resistance exceeds the values noted above. Attachment Resistance Expressed as a Moment - M, (ft-Ibf) from PA 101 Testing Tile Application Mortar Set 20.60 Adhesive Set Attachment Resistance 86.61 Capri Tile Table 4: Tile Profile t; UNIVERSAL TRIM Product Control No.: ...go .4-0 07 31' 0 15" 0.11' -• 0 1r PROFII.E. DRAWINGS (CONTINUED) ... 45• I 70 0 131 Proauct Control No.: ......;\„--!‘ A'%--;% %.--/\/N..""'■ /■_,. . , -, \,..\ ... \\‘ \\\ \. , .. \ \ , \ \., -----(, , , \ \I ,, \,, ....--..., .7, v v v k. v t. APPROVED SCREW FOR SCREW DATA IN TABLE 3 17 ; _n (1.1. )VOTI 1. Extensions of Acceptatce may be considered after a new application has been filed and the supporting data, test reports no ol4r than ten (10) years, have been re- evaluated. All reports of re- testin shall bear the scal, signature and date of an engineer registered in the State of Florida. 2. Any revision or chat'g in the materials, use, or manufacture of the product or process shall automatically be cause for terminatio , unless prior approval is granted for revisions or change. 3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds for re- evaluation. 4. This acceptance shall of be used as an endorsement of any product for sales or advertising purposes. 5. The Notice of Accep nce number preceded by the words Dade County, Florida, and followed by the expiration date may e displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 6. Product approval dra vings, where required for permit applications, shall be provided to the applicant by the manufacturer or is distributors unless otherwise noted in the Notice of Acceptance. The prints need not be re- sealed by a engineer. 7. Failure to comply wit the Standard Conditions shall be cause for termination of the Approval. This approval supersedes al BUILDING CODE COMPLIANCE DEPARTMENT SUITE 1603 METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 E OF ACCEPTANCE: STANDARD CONDITIONS (305) 375 -2901 FAX (305) 376-2908 previous approvals. 18 Raul Rodriguez Product Control Supervisor METROPOLITAN DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING .71t),/ 1 1. 16 V 31 V. 46 2 17 32 47 3 18 33 48 4 19 34 49 5 20 35 50 6 21 36 51 7 22 37 52 8 23 38 53 9 24 39 54 10 25 40 55 11 26 41 56 12 27 42 57 13 28 43 58 14 29 44 59 15 f 30 / 45 / 60 P.A. PEDRO A. HERNANDZ P.E. P p .o. box 650127. miomu. Hondo 33165 / 13216 s.w. 46 lone CONSULTING ENGIN RS Client: K Permit # Roof area (appro Roof Max. Heigh Date Tested: ,. LOCATIONS/ RESULTS P=Pas F =Fail Pedro A. H andez, P.E. ' ..,TE OF FIELD STATIC UPLIFT TEST FOR MORTAR SET TILE SYSTEMS Date: Job Address:, 27 ;JZ ?7 - ; , Type of Tile:7v34_5 7 - 5 CLf-y, Roof Pitch: ,Q a /z Date of Tile Installation: Uplift pull: 35 lbs. L fop ) � Roof tiles installation comply with South Florida Building Code 3401.11 (b)(1)(ee) and Cade County Protocol PA 106 HEIR/ Lab Certificate No. 94- 0909.01 /3 COMP. BY: ( f U / CHK. BY: PROJECT: ( /l) 9 7 s7 -/ A al . DATE: 4�r 17 88 LL_t SHEET NO: 0 A./. Tfs !L 5 m►cE-2:). 'T' \L otz �1. (I6 IF / • 0 • B' P.R. PEDRO A. HERNR DEZ, P.E., PR p.o. box 650127, miomi, florido 33165 / 13216 s.w. 46 lone CONSULTING EN INEERS 30 II 37 s-. " as 38' -" 12 ws GI Permit __ Owner's Name and Address Registered Architect and /or Engineer Employing Electrician's Name Location and Legal Description Lot Street and Number where work is to be performer —No. Amount of Permit $ STATE OF FLORIDA, COUNTY OF DADE. ss. MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity 0,42 the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division. of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. No._ No .Street, Block State work to be performed and purpose of building (By Floors) New Building — Remodeling Addition. Repairs —___ No. of St^_-ies. Service Overhead Size Feeders Conduit__________ — Main Sw.___________ __ Amps. __ Main Fuses__ Underground Type of Installation— Conduit Tubing __ B.X.L Metal Moulding __________________ ____ — — (Signed) (Signed) Date Street --^-- __-- ___ _______--- - - - - -. Subdivision ______________— _______ —___ Amps. Electrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has con plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work tr performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as a required by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is tbe_ �_____�_�, of the above described construction, that be has carefully read the foregoing application. and that he did sign the same, and that all facts therein by him stated are true. My Commission Expires Notary Public. State of Florida Master Elcctrican. NOTE: A re- inspection fee of $1.00 will be made when such re- inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. SWITCH OUTLETS LIGHT OUTLETS PLUG RECE'P'T'S FIXTURES NO.LAMPS REFRIG. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. WATER HEATER W. HEAT. CONN. SPACE HATER STRIP Y HEATER TOTAL CONTR. LIST CHECK ENT. SW. DIST. CAB. SERVICE TEMP. SERVICE PERM. MOTORS 0-1 HP MOTORS 1 -5 HP NEON TRANS. RADIO - -Y TOTAL CONTR. LIST CHECK Permit __ Owner's Name and Address Registered Architect and /or Engineer Employing Electrician's Name Location and Legal Description Lot Street and Number where work is to be performer —No. Amount of Permit $ STATE OF FLORIDA, COUNTY OF DADE. ss. MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity 0,42 the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division. of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. No._ No .Street, Block State work to be performed and purpose of building (By Floors) New Building — Remodeling Addition. Repairs —___ No. of St^_-ies. Service Overhead Size Feeders Conduit__________ — Main Sw.___________ __ Amps. __ Main Fuses__ Underground Type of Installation— Conduit Tubing __ B.X.L Metal Moulding __________________ ____ — — (Signed) (Signed) Date Street --^-- __-- ___ _______--- - - - - -. Subdivision ______________— _______ —___ Amps. Electrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has con plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work tr performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as a required by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is tbe_ �_____�_�, of the above described construction, that be has carefully read the foregoing application. and that he did sign the same, and that all facts therein by him stated are true. My Commission Expires Notary Public. State of Florida Master Elcctrican. NOTE: A re- inspection fee of $1.00 will be made when such re- inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. Permit No _-_, 2_ MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Date__.. Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Divisicn of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address Registered Architect and /or Engineer _ Employing Electrician's Name Location and Legal Description Lot_ Street and Number where work is to be performed —No State work to be performed and purpose of building (By Floors) Block No._________ Street___ No. – – – – – Street Street New Building Remodeling Addition. Repairs No. of. Stories Service Overhead Size Feeders.____ Conduit._________ Main Sw. Underground Type of Installation— Conduit_____. Tubing B.X.L Metal Moulding Amount of Permit $ (Signed) (Signed) Amps. Main My Commission Expires Notary Public. State of Florida Electrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has com- plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Master Electrican. STATE OF FLORIDA, ss COUNTY OF DADE.' Before me, the undersigned authority. a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the_ of the above described construction, that be has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re- inspection fee of $1.00 will be made when such re- inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. SWITCH OUTLETS LIGHT OUTLETS PLUG RECE'P'T'8 FIXTURES NO.LAM PS REFRIG. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. TER EATER W. HEAT. CONN. SPACE HEATER STRIP HEA'iER TOTAL CONTR. LIST CHECK ENT. SW. DIST. CAB. SERVICE TEMP. SERVICE PERM. MOTORS 0-1 HP MOTORS 1 -5 HP NEON TRANS. RADIO TOTAL CONTR. LIST CHECK Permit No _-_, 2_ MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Date__.. Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Divisicn of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address Registered Architect and /or Engineer _ Employing Electrician's Name Location and Legal Description Lot_ Street and Number where work is to be performed —No State work to be performed and purpose of building (By Floors) Block No._________ Street___ No. – – – – – Street Street New Building Remodeling Addition. Repairs No. of. Stories Service Overhead Size Feeders.____ Conduit._________ Main Sw. Underground Type of Installation— Conduit_____. Tubing B.X.L Metal Moulding Amount of Permit $ (Signed) (Signed) Amps. Main My Commission Expires Notary Public. State of Florida Electrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has com- plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Master Electrican. STATE OF FLORIDA, ss COUNTY OF DADE.' Before me, the undersigned authority. a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the_ of the above described construction, that be has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re- inspection fee of $1.00 will be made when such re- inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. Permit No.____— _______- ________ Date_- - - -_ ( r Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all previsions cf the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shor_:: Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building durizg _.rogreu of work. Owner's Name and Address Registered Architect and /or Engineer Employing Electrician's Name .t_ Location and ' ega1 Description Lot Street and Number wh rz wcrl: is to be performed —No State work to be performed and purpose of building (By Floors) New Building.. _______. Remodeling Addition Repairs —___ No. of Stories APPLICATION FOR ELECTRICAL PERMIT Scrvi:e Overhead Size Feeders Conduit.__________ Main Sw. Amps. Main Fuses____________ _ Amps. Underground Type of Installation— Conduit Tubing B.X.L Metal Moulding _________ _______ �__— ___— ___— ______— __________ Amount of Permit $___ STATE OF FLORIDA, COUNTY OF DADE. ss. My Commission Ea:pires MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT Street____ 1 No l Block (Signed) (Signed) ______ Notary Public. State of Florida Street Subdivision_______________ Street ' Master Electrican. IC _ . Electrical Inspector, The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has com- plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are LLquire.d by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared — — -- to me well known, and who, being by me first duly sworn, upon oath deposes and says that be is the_ __________ of the above described construction, that be has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re- inspection fee or "1.00 will be made when such re- inspection is made nccessary by improper notice for inspection, or f' materials end /or workmanship. a. CWITCH OUTLETS LIGHT OUTLETS PLUG RECE'P'T'S FIXTURES NO. LAMPS REFRIG. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. WATER HEATER W. HEAT. CONN. SPACE HEATER STRIP HEATER TOTAL CONTR. LIST CHECK ENT. DIST. SW. C.B. SERVICE TEMP. SERVICE PERM. MOTORS O -T HP MOTORS 1 -5 HP NEON TRANS. RADIO TOTAL CONTR. LIE CHECK Permit No.____— _______- ________ Date_- - - -_ ( r Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all previsions cf the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shor_:: Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building durizg _.rogreu of work. Owner's Name and Address Registered Architect and /or Engineer Employing Electrician's Name .t_ Location and ' ega1 Description Lot Street and Number wh rz wcrl: is to be performed —No State work to be performed and purpose of building (By Floors) New Building.. _______. Remodeling Addition Repairs —___ No. of Stories APPLICATION FOR ELECTRICAL PERMIT Scrvi:e Overhead Size Feeders Conduit.__________ Main Sw. Amps. Main Fuses____________ _ Amps. Underground Type of Installation— Conduit Tubing B.X.L Metal Moulding _________ _______ �__— ___— ___— ______— __________ Amount of Permit $___ STATE OF FLORIDA, COUNTY OF DADE. ss. My Commission Ea:pires MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT Street____ 1 No l Block (Signed) (Signed) ______ Notary Public. State of Florida Street Subdivision_______________ Street ' Master Electrican. IC _ . Electrical Inspector, The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has com- plied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are LLquire.d by the Act. The under signed agrees to employ only such sub - contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared — — -- to me well known, and who, being by me first duly sworn, upon oath deposes and says that be is the_ __________ of the above described construction, that be has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re- inspection fee or "1.00 will be made when such re- inspection is made nccessary by improper notice for inspection, or f' materials end /or workmanship. a. BUILDING ELECTRICAL PLUMBING Owner of Building Architect Contractor or Builder CONTRACTOR OR RU DER MIAMI SHORES VILLAGE, FLORIDA DATE PERMIT N9 2971 Contractor's License No. Work to be performed under this Permit Subdi- vision Value of Project Legal Lot ii Bl. Description Address of Building This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described application herefor in strict compliance with ali ordinances pertaining thereto and with the understanding that the work will be performed in con with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Perr be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further co upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowl the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specificatic that he assumes responsibility for work done by his agents, servants or employees. Signed. By V INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and Lions pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servant or employee. Amt. of Permit BY AUTHORITY NO. Motors Receptacles Generators STREET PART OF LOT LOT BL'K Other Apparatus SUBDIVISION . 7 9 ‘ t - i 1 ' ' " 1 4.- ;10 :di Outlets Motors Receptacles Generators Stoves Water Heaters Signs Billboards Other Apparatus Permit Fee it ?S "... ELECTRICAL PERMIT N. B. —This Permit must be on display on the premises during the construction. Owner of Building li ractor or Electricia iami =Di ores 9l lage Miami Shores Village, Fla , F L 0 A D A OFFICE OF ELECTRICAL DEPARTMENT i DESCRIPTION OF WORK NUMBER OF LO CATI 0 N 19 N9 805 This Permit is granted upon the express condition that all facts stated in the Application are true and that the construction complies strictly with the plans and specifications submitted and are in accordance with the Electrical Laws of the State of Florida and with the Electrical Ordinances and Code of Miami Shores Village and the rules and regulations of the Electrical Department of Miami Shores Village. This Permit may be revoked at any time upon the violation of any provisions of said laws, ordinances, or rules and regulations, or upon . y ange ' the plans and specifications unauthorized by th' Department. / r In consideration of the issuance to me of the foregoing Electrical Permit, I hereby agree to do the proposed construction in strict conformity with the Application and the plans and specifications thereof heretofore by me submitted, and in compliance with all provisions of all Electrical Laws of the State of Florida, all the Electrical Ordinances and Codes of Miami Shores Village, and all rules and regulations of the Electrical Department of Miami Shores Village. Dated [� - -____ , 19_ , Electrical Inspector. (Seal) NO. STREET mr, PART OF LOT LO BUR SUBDIVISION Signs Outlets Motors Receptacles Generators Stoves Water Heaters Signs Billboards Other Apparatus Permit Fee .„a,.rf N. B. —This Permit must be on display on the premises during the construction. Owner of Building ELECTRICAL PERMIT actor or Electrician Dated tiset , 194 OFFICE OF ELECTRICAL DEPARTMENT Miami Shores Village, Fla , r 19 s `'� y' r .0 CATI O N dd M iami cJhoresllage F L O R ID A DESCRIPTION OF WORK NUMBER OF N° 705 This Permit is granted upon the express condition that all facts stated in the Application are true and that the construction complies strictly with the plans and specifications submitted and are in accordance with the Electrical Laws of the State of Florida and with the Electrical Ordinances and Code of Miami Shores Village and the rules and regulations of the Electrical Department of Miami Shores Village. This Permit may be revoked at any time upon the violation of any provisions of said laws, ordinances, or rules and regulations, or upon any change in the plans and specifications unauthorized by epartment. , Electrical Inspector. In consideration of the issuance to me of the foregoing Electrical Permit, I hereby agree to do the proposed construction in strict conformity with the Application and the plans and specifications thereof heretofore by me submitted, and in compliance with all provisions of all Electrical Laws of the State of Florida, all the Electrical Ordinances and Codes of Miami Shores Village, and all rules and regulations of the Electrical Department of Miami Shores Village. (Seal) r i MIA • ' ES VIL..AGE, FLA. NO 5964' JOB _ ✓_ �� ���� ��� ADDRESS INSPECTION .r / F ' / °$ff TIME READY � - A REMARKS • 1 �• __aim. 7 , of EE. S.JG Phone ,l4. P' ' ' e-- 7 - C.o. INSPECTOR 1,31'e G - /8 -4 DATE Registered Architect and/or_ or _ Aineer Employing Electrician's Name..2 - . Service Overhead Underground Type of Installati�o jj G Amount of Permit $ STATE OF FLORIDA, } COUNTY OF DADE. A My Commission Expires MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Permit No Date Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address. No h.... Street y ; G, A i % ti • -N Location and Legal Description Lot Block Subdivision Street and Number where work is to be performed —No Street State work to be performed and purpose of building (By Floors) New Building Remodeling Addition Repairs No. of Stories Size Feeders Conduit Main Sw Amps Main Fuses Amps nduit ,. Tubing - B.X.E ' Metal Moulding �. (� / e 7r� ..:..... • I 1 ; (Signed) lectrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obli ations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub-contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub-contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Street Notary Public, State of Florida (Signed) Master Electrician. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, and he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re•inspection fee of $1.00 will be made when such re-inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. SWITCH OUTLETS LIGHT OUTLETS PLUG RECE'P'T'S FIXTURES NO. LAMPS REFRIO. OUTLET IRON OUTLET RANGE OUTLET RANGE CONN. WATER HEATER W. HEAT. CONN. ACE H ATER STRIP HEATER TOTAL CONTR. LIST CHECK ENT. SW. DIST. CAS. SERVICE TEMP. SERVICE PERM. `i MOTORS 0.1 HP MOTORS 1.8 HP NEON TRANS. RADIO TOTAL CONTR. LIST �/ St CHECK Registered Architect and/or_ or _ Aineer Employing Electrician's Name..2 - . Service Overhead Underground Type of Installati�o jj G Amount of Permit $ STATE OF FLORIDA, } COUNTY OF DADE. A My Commission Expires MIAMI SHORES VILLAGE ELECTRICAL INSPECTION DEPARTMENT APPLICATION FOR ELECTRICAL PERMIT Permit No Date Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of work. Owner's Name and Address. No h.... Street y ; G, A i % ti • -N Location and Legal Description Lot Block Subdivision Street and Number where work is to be performed —No Street State work to be performed and purpose of building (By Floors) New Building Remodeling Addition Repairs No. of Stories Size Feeders Conduit Main Sw Amps Main Fuses Amps nduit ,. Tubing - B.X.E ' Metal Moulding �. (� / e 7r� ..:..... • I 1 ; (Signed) lectrical Inspector. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obli ations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub-contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such sub-contractors, on work to be performed under this permit, as are licensed by Miami Shores Village. Street Notary Public, State of Florida (Signed) Master Electrician. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, and he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. NOTE: A re•inspection fee of $1.00 will be made when such re-inspection is made necessary by improper notice for inspection, or faulty materials and /or workmanship. P RMIT APPLICATION FOR MIAMI SHORES VILLAGE Job Address /-3 D(3 -39d 9 ( i t 7! E• sq`1 ., Tax Folio Date Legal Description Owner / Lessee ! rr Tenant f(ia�i r� Master Permit q Owner's Address �C Q L 4. E. / % / Phone ' 751 — Q2, e7.54/5 4924dcd-litx-e Contracting Co ?hone 5 Stace = 9I0O .unicipa: :r Architect /Engineer Bonding Company Address Mortgagor Address Permit Type(circie one) BUILDING( ELECiRICA MECHANICAL ROOFING PAVING FENCE SIG - WORK DESCRIPTION • /— �-� ' // Square Ft. Estimated Cost(value) WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TC SO MAY RESULT IN YOUR ?AY:NG TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEN: TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU: NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, an on the attached addendum (if applicable). I certify that all work will be performed to meet t- standards of all laws regulating construction in this jurisdiction. I understand that separat permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing informat be done in compliance with all applicable laws regulating c authorize the above -named contractor to do the work state Signature of oT r and /or Condo President Date: Notary a My Commi ** * APPROVED: 1 i 12 al .. ` ' N �° �« •4-a• :_ i resCC714091 - 4. �51/ COMMISSION EXPIRES e O1' - ,..._ MAR. 1,2002 * * Zoning * * resident * FEES: PERMIT '4 ✓ e2 RADON C.C.F. Fire Building * * Mechanical Address Competency f Address Si Da Notary My Co' Las.Co. on is accurate and that all work wil truction and zoning. Furthermore, ature of Contractor or Owner - Builder ean ° &HtRISCPw OOMPASON NUMBER . O F Mb COMMISSION EXP}kS MAR. 12002 NOTARY TOTAL DUE Electrical _r-Builder * x Other Plumbing Engineering