Loading...
MECHANICALMI�DADE BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) Rolladen, Inc. 550 Ansin Blvd. Hallandale, FL 33009 MIAMI -DADE COUNTY, FLORIDA METRO -DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone. DESCRIPTION: Series " #1116" Extruded Aluminum Roll Shutter APPROVAL DOCUMENT: Drawing No. 95 -12, titled "RollShutter Detail, Post Loading Charts, Top Support Loading Charts & Storm Bar Loading Charts ", sheets 1 through 21, prepared, signed and sealed Humayoun Farooq, P.E., dated 02/27/95 with last revision on 05/17/04, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 02- 0318.11 and, consists of this page, evidence page and the approval document mentioned above. The submitted documentation was revised by Can ' Font PE. INP NOA No 03- 0604.02 Expiration Date: June 6, 2007 Approval Date: June 24, 2004 Page 1 Rolladen, Inc. A. NOTICE OF ACCEPTANCE: EVIDENCE PAGE DRAWINGS 1. Drawing prepared by AI- Farooq Corporation, titled "Roll Shutter Detail, Post Loading Charts, Top Support Loading Charts, Storm Bar Loading Charts & Deflection Calculation Sheet" Drawing No. 95 -12, dated 02/27/95, with latest revision on 05/17/04, Sheets 1 through 21 of 21, signed and sealed by H. Farooq, P.E. B. TESTS 1. Test report on: 1.) Large Missile Impact Test per PA 201 -94 2.) Cyclic Wind Pressure Test per PA 203 -94 Of Roll Shutter prepared by Hurricane Engineering & Testing, Inc., Report No. HETI -94- 139 & 280, dated 06/0994 & 08/30/94, signed and sealed by H. M. Medina, P.E. 2. Test report on: 1.) Uniform Static Air Pressure Test per PA 202 -94 Of Roll Shutter prepared by Hurricane Engineering & Testing, Inc., Report No. HETI -94- 123, 250, 286, 297 & 308, dated 05/24/94, 08/12/94, 09/06/94, 09/16/94, & 09/22/94 signed and sealed by H. M. Medina, P.E. 3. Test report on: 1 ) Large Missile Impact Test per PA 201 Of Roll Shutter prepared by Hurricane Engineering & Testing, Inc., Report No. HETI -94- 325i, 95 -461 & 96 -524, dated 10/05/94, 06/22/95 & 01/31/96, signed and sealed by H M Medina, PE. C. CALCULATIONS 1. Calculations for Multiple Span Roll Shutter prepared by Al- Farooq Corporation with the following sections: Description D1, Test Reports RI to R10, Single & Multiple Span Graphs Si & S2, Track Connection Calculations Ti to T10, Storm Bars SB1 to SB93, Header HI to H40, Mullion M1 to M80 & Anchor Data Al to A3, signed and sealed by H. Farooq on 03/02/95. D. QUALITY ASSURANCE. 1 1. Building Code Compliance Office E. MATERIAL CERTIFICATIONS 1. Tensile Test Report No. HETI- 94 -T31 prepared by Hurricane Engineering & Testing, Inc. dated 10/12/94, tested as per ASTM E8 -93, signed and sealed by Hector M. Medina, P.E. 2. Letter of Aluminum Alloy Compliance issued by William L. Bonnell Co., Inc. on 09/13/94, signed by C. Combs. F. STATEMENTS 1. Letter of no change issued by Rolladen, Inc. on 03/15/02, signed by T. by E. M. Roldan. 2. Letter of engineer in practice issued by Al- Farooq Corporation on sealed by H. Farooq PE. E -1 D. Low and notarized 03/12/02, signed and Candido F. ont PE Senior Product Control Examiner NOA No 03- 0604,02 Expiration Date: June 6, 2007 Approval Date: June 24, 2004 Qualifier t� �. - State # CAe 05700k) Jzs7 - Ag? / — /d..) otary as to Owner and/or Condo P My Commission E 40 FEES: PERMIT J RADON C1 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date • Jo' ' dress 17-'1 A`l . — . S') Sr. Tax Folio i 1 - 3acC, - D t '3 Legal Description Historically Designated: Yes No Owner/Lessee / Tenant ee Master Permit # L fvf Owners Address 17`l e .e= . G'1 Ste. �z �� � 11. 3 Phone (&..) Contracting Co. j vmC.0 Address t- -1ls0O S -C..D • j"15 AVM . Municipal # Signature of owner and/or Condo President Date e r, .,, CARLENEVERRIW = : MY COMMISSION # DD 027218 �. '' tember 18, 2005 `,04 ��� ,,. EXPIRES Sep Bonded Thr., Neva Public Underwriters 2 SS# , Phone � �> aC.tl - L DcT Competency # Address Address Ins. Co. Architect/Engineer Bonding Company Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAt)ROOFING PAVING FENCE SIGN WORK DESCRIPTION ce - Z �cka6d" �w r Square Ft Estimated Cost (value) '7Soo WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. APPROVED: Zoning Building Mechanical /"'` ' v ' •° Plumbing Signature of Contractor or Owner -B =1der ary as to Contractor or Owner - Builder My Commission C.C.F. I NOTARY t•;'� s CARLENE VERRIW . ��,, :e s MY COMMISSION # DD 027218 " EXPIRES: September 18, 2005 • 1,/ B onded Thw Notary Patto UndarwrfWro Electrical d d_S 1.) cue 74.43C2,4:e BOND Date TOTAL DUE ( Q/ 2 3//b Date / 0 Engineering NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO: • • 9 16 TAX FOLIO NO. 1 - 370(0 — 0 — .746,0 STATE OF FLORIDA: 0 iR409257 2001 AUG 02 10:35 COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713 Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: \ Z rJ ° ) S T m z'`''ti'a gbvc-aeTSS Y(- • 33N 35Z 2. Description of improvement: +z. of °''' ? r ���€ a,rzv T...s TA / - %v.i J-y/s as S..xr7_ n 69,2 /�.ah+S /2 7 A .E. 97 ST. /77i.v�sa ..�4✓ 3. Owner(s) name and address: 33/3 Interest in property: Name and address of fee simple titleholder: C2A 7 • 33i3' 4. Contractor's name and address: gC.i°vsce 3S 'S:S" 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lenders name andk address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: OA, ATC11 ISO- OWES REA OOF L 01. AI IRE l Sworn to and subsc. Expiration date of this Notice of Commencement: (the expiration date Is 1 year from the date of recording unless a Int date Is specified) Signior• 01 Print Owners N. kr .,zfts 4HY kS :TE _ Notary Public Print Notary' a My Commission Expires: to me this r J d .. �2AS('fl6 /-2'2 N - & . S.9 S> • rrJaA�s EXPIRES: September 18, 200 titers �Xi�bxTS 4/6:3406 J • Gel . 7.S •4- , /2".rAn^i l I"d Prepared by: - -. Address: •lovo G.w . IT,. 331SS 129.0162 11900 NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION 33 /SS - g •.3/3 PERMIT NO: ' 7'110 STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: \ 2 el N C . QC ST • , YY zw mz g.vc. 5 ! r(• • 33% 2. Description of improvement: Ich oa , 7is►cc /- /can, :041„00 -- • rr_ 3. Owner(s) name and address: & 0 9 c� c.9ETi9 i s - 0 -E. 9-2 , S . , 179•7,9,07 z --✓wz Interest in property: Name and address of fee simple titleholder: ‘;24c6- c6 -6 . 9-7 7e . . 33/32, 4. Contractor's name and address: vsc� V. 4 s- ceW . 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 6. Lenders name and address: 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name, and address: 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Signature of orrnar n Print Owners Name C� �z krz zAs Sworn to and subscribed bef , e me this - 51 d r :::• • : Notary Public Print Notary - Name My Commission Expires: TAX FOLIO NO. 3.70G — EXPIRES: September 18, 2005 rs 0 HEREWV CERTIFY II :a3 ro.3 49 a tr..o copy c?thc> anrginal Oiled in thi otbco on C31). on A O 20 WITNESS my hand d Official eat. r ARV Y RUllli�,. K -�t tut an te d County Courts 01R409257 2001 AUG 02 10:35 Prepared by: &AA -ir Address: 4 4(060 G.W Ave r 33 53 I 123.01-52 10108 RHVAC - Residential & Light Convnercial HVAC Loads Program Gemairo Distributors, Inc. Miami, FL 33122 ' 07-06 -09 Project Summary Client: Address: City: Phone: Fax: Design Data Project Name: Reference City: Daily Temperature Range: Latitude: Elevation: Winter: Summer Check Figures Total Building Supply CFM: 250 Square feet of room area: 199 Building Loads GRACE ARRAZCAETA 127 NORTHEAST 97 ST. MIAMI SHORES, FL. 305 -757 -7559 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum. Dry , = ulb Difference 40 N/A N/A 72 N/A 92 78 50% 75 58 Total heating required with outside air. Total sensible gain: Total latent gain: Total cooling required with outside air: Notes 8,479 Btuh 6,266 Btuh 854 Btuh 7,120 Btuh Company: Representative: Address: City: Phone: Fax: Comment: NEW MINISPLIT SYSTEM AIR CONDITIONER Miami, Florida Low 45 Degrees 7 Feet CFM per square foot: 1.256 Square feet per ton: 293.45 Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both, sensible and latent loads. Elite Software Development, Inc. NEW MINISPUT SYSTEM AIR CONDITIONER Page 1 SERVICE EXPERTS, INC. JOSE PEREZ 4600 SOUTHWEST 75 AVE. MIAMI, FL. 33155 305 -264 -2020 8.479 MBH 88 % 12 % 0.593 Tons (based on sensible + latent) 0.678 Tons (based on 77% sensible capacity) Tuesday- -�� h RHVAC - Residential & Light Commercial HVAC Loads Program Elite Software Development, Inc. Gemaire Distributors, Inc. NEW MINISPLrr SYSTEM AIR CONDITIONER Miami, FL 33122 1 07-06-01 Page 2 Total Building Summary Loads Component Description 1C Window Clear Glass Metal Frame 16 591 0 1,386 1,386 14A Wall 8" or 12" Block No Insulation Unfinished 340 5,549 0 2,999 2,999 16D Ceiling R -19 Insulation 199 338 0 475 475 22A Slab on Grade No Edge Insulation 44 1,140 0 0 0 Subtotals for structure: 599 7,618 0 4,860 4,860 Active People: 0 0 0 0 0 Inactive People: 0 0 0 0 0 Appliances: 0 0 0 1,000 1,000 Lighting: 0 0 0 Ductwork: 0 0 0 0 0 Infiltration: Winter CFM: 24.4, Summer CFM: 21.7 16 861 854 406 1,260 Ventilation: Winter CFM: 0.0, Summer CFM: 0.0 0 0 0 0 0 Sensible Gain Total: 6,266 Temperature Swing Multiplier: X1.00 Building Load Totals: 8,479 854 6,266 7,120 Check Figures Total Building Supply CFM: 250 CFM per square foot: 1.256 Square feet of room area: 199 Square feet per ton: 293.45 Building Loads Area Sen. Lat. Sen. Total Quan Loss Gaon Gain Gain Total heating required with outside air. 8,479 Btuh 8.479 MBH Total sensible gain: 6,266 Btuh 88 % Total latent gain: 854 Btuh 12 % Total cooling required with outside air: 7,120 Btuh 0.593 Tons (based on sensible + latent) 0.678 Tons (based on 77% sensible capacity) Notes Calculations are based on 7th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent Toads. RHVAC - Residential & Light Commercial HVAC Loads Program Gemaire Distributors. Inc. Miami, FL 33122 ' p ' Room Load Summary Reports System #1 Room Load Summary Htg Htg Run CIg CIg CIg Zone Clg Air Room Area Sens Nom Duct Sens Lat Nom Adj Adj Sys No Description SF Btuh CFM Size Btuh Btuh CFM Fact CFM CFM —Zone 1- 1 Study 199 8,479 250 3 -5 6,266 854 250 1.00 285 250 System 1 Totals 199 8,479 250 6,266 854 250 285 250 Main Trunk Size: 8x6 in. System #1 Cooling System Summary Cooling Sensible /Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 0.593 88 %/12% 6,266 854 7,120 Recommended: 0.678 77 %123% 6,266 1,872 8,138 Actual: 0.750 9,000 System #1 Equipment Data 0706-01 Heating System Cooling System Type: Standard A/C Model: TNL -S1211 Brand: APOLLO Efficiency: 10.0 Blower CFM: 250 Capacity: 9,000 Btuh EI"Re Software Development, Inc. NEW MINISPLIT SYSTEM AIR CONDITIONER Page 3