1219 NE 96 St (5)Owner's Name and Address Paul Kinney
Disapproved / Pate t'
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
No
Date.. - - - - -- March 27th, , 19 58
1217 street N. E. 96th St., Miami
Shores
Registered Architect and /or Engineer
Name and address of licensed contractor Lang Roofing & Tile Co., Inc., 430 N. W. 79th St., Miami Fla.
Location and legal description of lot to be built on:
Lot Block Subdivision
Street and Number where work is to be done 1217 N. E. 96th St.., Miami Shores, Fla.
State work to be done and purpose of building (by floors)
and for no other purpose.
New Building Remodeling Addition X Repairs No. of Stories
To be constructed of Kind of foundation Roof Covering 30# felt, 900 slate
Estimated Total cost of improvements $ 1 00.00 Amount of Permit $ Cuban tile.
Zone cubage required .Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Pennanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed tinder this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ ctply__wch sg)�cpgtoac o w Ah perf�pgg ed under this
pennit, as are licensed by Miami Shores Village. LAIV tt U 11 V l,u , lives .9
Remarks
STATE OF FLORIDA,
COUNTY OF DADE. J ss
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
(Signed) CeY "4-sltr---.^
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true. /
Permit No e' 3 Date 3 - z - Read, Sworn to and Subscribed before me.
Notary Public, State of Florida
Building In'.ector My Commission Expires
/ PLANNING BOARD DATE
Chairman Member
Member Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
(Signed)
Phone #
Date
Inspection Date
Approved
Correction
Re- Insp'n Fee
MIAMI SHORES VILLAGE
BUILDING DEPARTMENT
305 -795 -2204
Building Inspection Request
5 (Lt
Type Insp'n y f1O ' -1 l ` l c��
Permit No. 2P oil- J fl
Name mun tem
Address (0(024 I I" 11
CompanC,OnV Dt ciJ
Phone #
Inspection Date
• s
Approved
Correction
Re- Insp'n Fee
MIAMI SHORES VILLAGE
BUILDING DEPARTMENT
305- 795 -2204
Building Inspection Request
Date
Type Insp'n j � � D 71 fl
(ono —1 tI
Permit No. BP 1 9
Name //���
Add (0(02(0 v 1 ( `
Compan( O �(IJ
1`4
BUILDING TYPE
FASTENER TYPE
MIN. No. OF
FASTENERS
PER VERTICAL
JAMB
H„U IMUM
011 CENTER
C•STANCE
EIETWEEN
FASTENERS
STEEL
WASHERS
REQUIRED?
WOOD FRAME \
1 2" x 3" EMBED LAG SCREW (ASTM A307. GRADE A)
/ /4"
6
1-..;"
YES
YES
BLOCK WALL OR CONCRETE
1 x 1 -3/4" MIN. EMBED TAPCON CONCRETE ANCHOR
9
, r-�
BLO WALL OR CONCRETE
3/8' x 1-3/4' MIN. EMBED RAWL —STUD EXPANSION ANCHOR (7400 SERIES)
5
19'
NO
BLOCK WALL OR CONCRETE
3/8" x 1 -3/4" MIN. EMBED RAWL LOK /BOLT ANCHOR BOLT (5000 SERIES)
6
1:;° —
NO
•
•
MODELS 83. 84A 87. 93 94. 97
2x6 JAMB TO SUPPORTING STRUCTURE ATTACHMENT
NOTES;:..
1) ALLL' 'THE LOAD FROM THE DOOR IS TRANSFERRED TO THE TRACK AND THEN FROM THE TRACK
TO THE 2x6 VERTICAL JAMBS (GRADE 2 OR BETTER YELLOW PINE). NO LOAD FROM THE
DOOR IS TRANSFERRED TO THE HORIZONTAL (TOP) JAMB.
2) EACH VERTICAL JAMB SEES A MAXIMUM DESIGN LOAD OF +2,982.4 LB & —3,328 LB AND
A MAXIMUM TEST LOAD OF 4,480 LB & —4,992 LB.
3) ALL JAMB FASTENERS MAY BE (BUT NOT REQUIRED) COUNTERSUNK TO PROVIDE A FLUSH MOUNTING SURFACE.
WOOD FRAME BUILDINGS
STUD WALLS OF DOOR OPENING SHALL BE FRAMED SOLID BY NOT LESS THAN (3) 2x6 PRESSURE
TREATED GRADE #2 OR BETTER WOOD STUD OF A STRESS GRADE NOT LESS THAN 1200 PSI NOMINAL
EXTREME FIBER STRESS IN BENDING (F ). STUD WALLS TO BE CONTINUOUS FROM FOOTING TO TIE BEAMS
AND IN ACCORDANCE WITH SFBC SECTION 2905.1.
BLOCK WALL OR CONCRETE
2x6 WOOD JAMB SHALL BE ANCHORED TO GROUT REINFORCED BLOCK WALL OR CONCRETE COLUMN.
BLOCK WALL CELLS SHALL BE FILLED WITH CONCRETE AND REINFORCED WITH #5 BAR EXTENDING
INTO THE FOOTING AND INTO 11E BEAMS. ALL BARS SHALL BE CONTINUOUS FROM THE TIE BEAMS
TO FOOTING PER BLOCK WALL OR CONCRETE COLUMN. BLOCK WALLS AND CONCRETE COLUMNS TO BE
DESIGNED BY BUILDING PROFESSIONAL OF RECORD AND IN ACCORDANCE WITH SFBC SECTION 2704.2.
2x6 JAMB TO SUPPORTING STRUCTURE ATTACHMENT
(NOT TO BE USED FOR ATTACHMENT OF TRACK ANGLE TO 2x6 VERTICAL JAMBS OR SUPPORTING STRUCTURE)
&MINIMUM DISTANCE BETWEEN CENTER OF ANCHOR AND EDGE OF CONCRETE BLOCK: 3 ", EXCLUDING STUCCO THICKNESS.
CLOPAY DOES NOT SUPPLY JAMB ATTACHMENT FASTENERS.
1" DOOR OVERLAP (EACH SIDE)
2x6 WOOD JAMB
SEE "JAMB PREPARATION
NOTE" ABOVE
12 GA. GALV. STEEL CONTINUOUS
ANGLE FASTENED TO WOOD JAMB
WITH 5/16 "x1 - 5/8" LAG SCREWS
NOT TO EXCEED 14" 0.C. CONTINUOUS
ANGLE MAY BE NOTCHED OUT AT JAMB
TO STRUCTURE ATTACHMENT POINTS.
2" GALV. STEEL TRACK FASTENED
TO 12 GA. GALV. STEEL TRACK CLIPS.
TRACK ATTACHED TO EACH CLIP
WITH TWO 1/4"x5/8" BOLTS & NUTS.
EACH TRACK CUP ATTACHED TO
CONTINUOUS ANGLE WITH
(2) 1/4" DIA. RIVETS PER CUP.
STOP MOULDING BY DOOR INSTALLER (TO SUIT)
16 GA. GALV. STEEL PAINTED END STILE
18 GA. GALV. STEEL DOUBLE END STILE
JAMB CONFIGURATION
SCALE 1" = 9"
20 GA. GALV. STEEL INTER. STILE
MAX. O.C.
•
•
7/16" NUT IS INSTALLED 18 GA. GALV. STEEL CENTER HINGE
ON ROLLER SHAFT FOR FASTENED TO INTER. STILES W /(4)
UNRESTRICTED OPERATION. EACH #14x5/8" SHEET METAL S.:REWS.
14 GA. GALV. STEEL ROLLER HINGES
FASTENED TO END STILES W /(4) EACH
#14x5/8" SHEET METAL SCREWS AND
(2) 1/4" SELF TAPPING SCREWS PER END HINGE.
2" DIA. LONG STEM, 10 BALL STEEL RiDLLER.
END OF ROLLER STEM THREADED FOR
7/16" NUT.
PAGE 2 OF 2
HORIZONTAL JAMB
� (NO LOAD FROM DOOR)
FASTENER
TYPE
MIN. No.
OF FASTENERS
PER VERTICAL
JAMB
2x6 VERTICAL JAMB
JAMB ;:REPARATION NOTE
EACH CONTINUOUS ANGLE TRACK SHALL BE FASTENED TO PRESSURE TREATED 2x6 YELLOW
PINE W000 JAMBS WITH 5/16 "x1 - 5/8" LAG SCREWS (12) LAG SCREWS PER SIDE UP TO
7'0" HIGH AND (13) LAG SCREWS PER SIDE UP TO 8'0 HIGH). THE METHOD OF ATTACHMENT
TO THE SUPPORTING STRUCTURE OF THE PRESSURE TREATED 2x6 WOOD JAMBS SHALL BE
APPROVED BY THE PROFESSIONAL OF RECORD FOR THE STRUCTURE AND IN ACCORDANCE WITH
CURRENT BUILDING CODES FOR THE LOADS USTED ON THIS DRAWING OR AS SHOWN
ON PACE 4 OF THIS DRAWING. PREPARATION OF JAMBS BY OTHERS.
ALL MCUNTING OF TRACK, ANGLES, HORIZONTAL TRACK SUPPORTS, AND ALL OTHER
DOOR HARDWARE TO BE INSTALLED PER CLOPAY INSTALLATION INSTRUCTIONS
SUPPLED WITH DOOR SYSTEM UNLESS OTHERWISE NOTED.
DESIGN ENGINEER
MARY W. WESTERFIELD, P.E.
FLORIDA REGISTRATION No. 48495
NM (lopay
Building Products
Company
TOLERANCES
Unless Stated Otherwise
REV
1
2
3
DATE
3/27/95
11/3/97
2/13/98
DESCRIPTION
ADDED JAMB DWG & CHART TO PAGE 4
REFIT DWG TO 2 PAGES
REV. JAMB ATTACH. FASTENERS ON PG. 2
INTER.
STILE
OUTSIDE
HANDLE
Clopay Corporation All Rights Reserved.
The arrangements depicted herein are the sole property
of the Clopay Corporation and may not be reproduced
in any form without it's written permission.
LOCK BAR
ENGAGES IN
OUTSIDE KEYED LOCK TRACK ON
LOCK BAR LOCKING EACH SIDE
CONFORMS TO SFBC 3603.2 OF DOOR.
INTER. STILE
OUTSIDE KEYED
HANDLE
INSIDE HANDLE
OUTSIDE KEYED LOCK
SNAP LATCH LOCK OPTION
CONFORMS TO SFBC 3603.2
DESIGN LOADS: +46.6 P.S.F. & —52.0 P.S.F.
TEST LOADS: +70.0 P.S.F. & —78.0 P.S.F.
.00 = ±.03
.000 = 1.015
.0000 = ±.007
Degrees = t1 /T
SNAP LATCH ENGAGES
ONTO VERTICAL TRACK.
ONE SNAP LATCH ON
EACH SIDE OF DOOR.
SCALE.
DATE.
END
STILE
LOCK
BAR
GUIDE
END
STILE
NOTED
2/15/95
DRAWN BY' MWW
CHECKED BYE
PAGE.
2 OF 2
SLIDE BOLT
LOCK ENGAGES
INTO VERTICAL
TRACK. ONE
LOCK ON
EACH SIDE
OF DOOR
INSIDE SLIDE BOLT
LOCK OPTION
CONFORMS TO SFBC 3603.2
APPROVED AS COMPLYING WITH THE
SOUTH FLORIDA BUILDING CODE
DAT III:: - 19gg
Lam
BY
PRODUCT 1 ROL DIVISION
BUILDING .CODE COMPLIANCE OFFICE
ACCEPTANCE NO. I Z22.6Z
MAX. SIZE
16'2'YJ x 8'0 "H
DESCRIPTION.
DOUBLE CAR HURRICANE PAN DOOR
DRAWING NUMBER.
101300
REV.
3
MODELS 83. 84A, 87, 93. 94, 97
LOCATION OF OPTIONAL VENTS
AREA OF VENTS NOT TO EXCEED
60 SO. INCHES BETWEEN STILES
w
CD
w
D_
0
ONE INTERMEDIATE STILE BETWEEN EACH EMBOSS LOCATION.
ATTACHED W/ PATENTED TOG —L —LOC SYSTEM (TOP & BOT)
AND URETHANE ADHESIVE (ALONG CENTER)
NOTE
DOORS UP TO 7' -0" HIGH CONSIST OF (4) SECTIONS (SHOWN).
DOORS OVER 7' -0" HIGH CONSIST OF (5) SECTIONS (NOT SHOWN).
INSTALLER
MODEL
93
94. 97
RETAIL
MODEL
83
84A, 87
DESCRIPTION
WOODGRAIN TEXTURE. RAISED PANEL, GALV. INTER. STILES
W000GRAIN TEXTURE. RAISED PANEL. PAINTED /GALV. INTER. STILES
HORIZONTAL TRACK SUPPORT BY
DOOR INSTALLER (TO SUIT)
DOOR COUNTERBALANCE SYSTEM
� L r�
r
r �
11
1)1
12 GA. GALV. STEEL CONTINUOUS
1 -5/8" x 2 -3/8" ANGLE.
76" (7'6 "H & 8'0 "H DOORS ONLY)
63"
50" 2" GALV. STEEL TRACK,
TRACK THICKNESS: .083"
38"
24"
10"
L-- ---- A OPTIONAL OUTSIDE KEYED LOCK POSITION
MAX. DOOR WIDTH = 16' -2"
INSIDE ELEVATIONS
SCALE 1" = 18"
TRACK CONFIGURATION
SCALE 1" = 36"
DOOR
HEIGHT "L"
6' -6"
7• -0
70"
76"
7' -6" 82"
8 " -0" 88
TYP. 2-1/2"x12 GA. GALV.
STEEL TRACK CLIPS.
DISTANCE FROM BOTTOM OF VERTICAL
TRACK TO EACH CLIP IS: 3-1/2",
10 ". 24 ", 38 ", 50 ", 63 ", AND
76" (7'6 "H & 8'0 "H DOORS ONLY)
ONE 5/16 "x1 -5/8" LAG SCREW PER
TRACK CLIP.
18 GA. GALV. DOUBLE END STILES
ATTACHED TO TOP AND BOTTOM RAIL
WITH PATENTED TOG —L —LOC SYSTEM.
1/4 "x3/4" SELF
TAPPING SCREWS.
14 GA. END HINGES
SCALE 1" = 9"
VIEW "B"
/
16 GA. PAINTED ENO STILES ATTACHED TO
SKIN WITH PATENTED TOG -1.—LOC SYSTEM
(TOP, BOTTOM & CENTER).
VIEW "C"
VIEW "B"
PA ° _3E 1 OF 2
LOCK POSITION
(BOTH SIDES)
TWO POINT LOCKIN.s
CONFORMS TO S'?=�
3603.2 REGARGINC
GARAGE DOORS VI H
5/8" MIN. ENGACE.IENT.
DOOR TESTED FOR
FORCED ENTRY St;`H
BOTH OUTSIDE KE T ED
LOCK AND INSIDE
SLIDE BOLT LOCI
OPTIONS (SEE
LAYOUT OF EACH
LOCK ON NEXT t•a3E).
24 GA. DQSK STEEL (!.+. M. YIELD STRENGTH:
38 KSI) EXTE - d3R SKIN WITH G -60
GALVANIZING, BAKE —ON PRIMER AND A
BAKED —ON POLYEST: PAINTED TOP COAT
APPLIED TO BOTH ;:'DES OF STEEL SKIN.
(ASTM No. A653).
#14x5/8" SHEET METAL SCR''' IS
SHIP LAP JOINTS.
18 GA. INTERMEDIATE HINGE
SCALE 1" = 9"
VIEW "C"
DESIGN ENGINE :2
2
MARK W. WESTI:2FIELD, P.E.
FLORIDA REGISTI•ATION No. 48495
MEP Cop
Building Products
Com•an
DOOR
2" THICK
TOLERANCES
Unless Stated Otherwise
ALUMINUM EXTRUSION & VINYL WEATHERSTRIP.
SECTION A —A (SIDE VIEW)
SCALE 1" = 9"
DESIGN LOADS: +46.6 P.S.F. & —52.0 P.S.F.
TEST LOADS: +70.0 P.S.F. & —78.0 P.S.F.
.00 = 1.03
.000 = 1.015
.0000 = ±.007
Degrees = ±1/2*
Clopoy Corporotion All Rights Reserved.
The arrangements depicted herein ore the sole property
of the Clopoy Corporation and moy not be reproduced
in ony form without it's • written permission.
REV DATE
1
2
3
3/27/95
11/3/97
2/13/98
ADDED JAMB DWG & CHART TO PAGE 4
REFIT DWG TO 2 PAGES
DQSK; VENT AREA; TRACK NOTE TO PG. 1
12 GA. GALV. STEEL TOP ROLLER BRACKET.
EACH BRACKET ATTACHED W/(4) #14x5/8"
SHEET METAL SCREWS. ADJUSTABLE SLIDE ATTACHED
TO TOP BRACKET WITH (2) 1/4"x1/2" BOLTS AND
NUTS PER BRACKET.
14 GA. GALV. ROLLER HINGE.
EACH HINGE FASTENED TO END
STILES W /(4) #14x5/8" SHEET METAL
AND (4) 1/4"x3/4" SELF TAPPING SCREWS.
(SEE VIEW "B ")
ONE 6" TALL C— CHANNEL PER DOOR SECTION. (SEE VIEW "D ")
C— CHANNEL ATTACHED AT EACH STILE LOCATION WITH
(1) 1/4 "x3/4" SELF TAPPING SCREW.
1-1/4" WIDE x 16 GA. GALV. STRAP. (7) PER
DOOR SECTION, EXCEPT (8) STRAPS ON 2ND
SECTION (SEE INSIDE ELEVATION). EACH STRAP ATTACHED
WITH (3) 1/4 "x3/4" SELF TAPPING SCREWS (TWO
SCREWS TO DOOR, ONE SCREW TO C— CHANNEL).
13 GA. GALV. STEEL BOTTOM BRACKET.
ATTACHED WITH (2) #14x5/8" SHEET METAL SCREWS.
SCALE.
DATE.
CHECKED BY
NOTED
2/15/95
DRAWN BY MWW
PAGE.
1 OF 2
13
2-1/2"
--1 I--- 5/8" (TYP.)
VIEW "0"
6" TALL C— CHANNEL
16 GA. GALV. STEEL
DESCRIPTION
APPROVED AS COMPLYING W:TH THE
SOUTH FLORIDA BUILDING CODE
DATED 19q
PRODUCT CONTROL DIVISION
BUILDING CODE COMPLIANCE OFFICE
ACCEPTANCE NO. 1222.1)1
DESCRIPTION.
DOUBLE CAR HURRICANE PAN DOOR
DRAWING NUMBER.
101300
MAX. SIZE
16'2 "W x 8'0 "H
REV.
3
BUILDING INSPECTION DEPARTMENT
PPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address..
Registered Architect and /or Engineer
Name and address of licensed contractor
Location and legal description of lot to be built on:
Lot / N / y Block
New Building
To be constructed of
Estimated Total cost of improvements $_
Disapproved Date
( Signed)
Building Inspector
.:HORES VILLAGE
Zat?
E 3 Subdivision
Date
Street and Number where work is to be done / L- /9 7 ,
State work to be done and pur l ose of building (by floors) -.--�C �tGP�GtIf � ��"� ° 4 Gf 7 CV!
c�-�._ ..._ ? -�=C -c a e . L -, ��,C.. �,�-• WvOre: p^
and for no other purpose.
Remodeling Addition `� Repairs No. of Stories
Kind f of foundation Roof Covering
d1._D '
Amount of Permit $
Zone cubage required .Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted f. pe•tion on the site of the Fork such public notice
or notices as are required by the Act. The undersigned agrees to employ only sue. subcon � ctoors, on work . . - performed under this
permit, as are licensed by Miami Shores Village. / � Z a
Remarks (Signed)
STATE OF FLORIDA, j
COUNTY OF DADE. ss
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No Date Read, Sworn to and Subscribed before me.
Notary Public, State of Florida
My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of $1.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 124'4 Job Address 12 19 NE Ci(0 s ✓
Legal Description W & 5 ' ofrilt �,� ✓.
/ Lessee / Tenant M DI C0IQC0rn0
Owner's Address
Contracting Co. 66ErinGLE &Or I r4( Address q 325 RX4/ L b e Su fr 4
Z
Qualifier �4rnes D Ol�z�'1mL 2 SS# - Phone 75 7 - 2( J
State # 62 Municipal # Competency # / O a . . Ins .Co I -h 1 c=1 LASE C
Architect /Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANIC RO PAVING FENCE SIGN
WORK DESCRIPTION Ieo-r
Square Ft. ;Up ,A14 4 , Estimated Cost(value)
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO
SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will
be done in compliance with all applicable laws regulating con str tion and zon Furthermore, I
authorize _ he above -named contractor to do the work stated.
1Z l°l
fir °1 1 1
Signature of owner and /or Condo President
Date:
My Commission Exp OVARY PUBLIC STATE OF FLORIDA
COMMISSIONNO.CC265272
MY COMMISSION EXP. MAI3.12,1997
** * * * * * * *
* *
FEES: PERMIT /V RADON C.C.F.
APPROVED: Fire
Zoning Building
Mechanical Plumbing_
Tax Folio I I - 320(n - Ott4 '-3s Iv
Master Permit # 1{/7
Phone
- Luro alg I I I - 75 % L1 -1 / 2LQ vJL tin
g
nature of Contractor or Owner- Builder
ate:
No •• iT;c :b • � � N®13ROwne Builder
My C ss ions" SriOrELOA
NOTARY P i F MATE
COMMISSION NO. CC2a52
COMMISSION EXP. MAR. 12,1°.:7
* **
NOTARY TOTAL DUE' "
Other
1 Electrical
Engineering_
STATE OF FLORIDA, COUNTY 0 DADE
par o:317 CER:!i'V : •a ; i; is c fr •p7 /ho
C 7i : :=t, . � _� C4 : x.
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO. l I 3 0(4 3 U ` 0
STATE OF FLORIDA:
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of propp and street address:
P. 1 q V 1 E `l b ST . (04-1&41 Shoves t 331-4r
2. Description of improvement: �.�✓ 00 �1 h
3. Owner(s) name and address: F.-1. r d 14rS a • t 1 4 14 co I.4 v
\?,L °I h E 4(a s-r.-. ki -‘s 33tiY
4. Contractor's name and address: Obcrov 1L Aco — (
rictoe
Signature of Owner /
Print Owners Name �d (t. ] /L 1)) ai 4G0 A O
Sworn to and subsc ibed before me this ! $ day of ec. , 19 3 .
Notary Publi
ry / ff I
Print Nota 's Name C� �f -�-v� e I'L ORI A .
My Commission Expires: COMMISSION NO. CC265251
fY_ COMMt99ICN i j' 73.16,.iy' -•i
''.- 1993 DE(: 16 12:37
Interest in property:
Name and address of fee simple titleholder: S C 4 IntiQi
LS
5. Surety:(Payment bond required by owner from contractor, if any) } F 30/S
Name and address:
Amount of bond $
6. Lender's name and address:
7. Persons within th'e State of F : ida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7. orida Statutes,
Name and address'
8. In additi•n to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address:
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Prepared by(
Address:
174/ p000d
330
id
123.01.52 2/93
r• $3 '-19 -91 09:01 AM FROM GAF TPA SALES
-
.S
METROPOUT4144 DADE COUNTY, FLORIDA
on•, mETAOrp
01%
METRO•D4ADE CENTER
IOARO OR RULES AND ANRALS
CQ06 V OACEMENT
&UIT6 10t0
III N.W.1$tSTREET
MIAMI, fLONOA $11214974
(305) 375.2d12
G. A. F.' Corporation
1361 Alps Road
'Wayne,. N.J. 07470. •
Your application for Product Approval of
:2 b ro S d "
laninfinmilembrognal under Sections 203 and 204 of the South Florida of
Building Code governing the'use of Alternate Materials and Types
Construction, and completely described in the Plana, specifications and
calculations as submitted by .-
• . t •• ' lationa SU,r: -
• . . .
- has been accepted to be
1 6 87 by Vin�n Tolat. p•E• td by Product C
County ontrol _
• used in the Unincorporated of Dade
and dard Coeditions on,Pago
CondZCionw� set forth on pee
• -
ACCEPTANCE "/ p.E ..
it Diamond
$ J,,,, la , 1991
roduct Control Division
supervisor
_ _ sa e h, 11 _ 1494
APPROVSD
SApzRSS
This application for Product Approval has b been in the
the
Metropolitan Dade County Board of Rules
Incorporated and Unincorporated areas of Dade Count under the
conditions'eet forth above•
APPROVED: June 10. 1991
Char es Danger, .6
Deputy Secretary
Metropolitan Dade County lg
Hoard of Rules and App
09=19 09:01 AM FROM GAF TPA SALES
r
approves smooth surfaced and granule surfaced, torch applied
APP
1.00. Ah? dP and mop _a pp lied SBS "Ruberoid MS single plyroofing
membranes which are polymer modified e ave$ mynb� _ y�ed in new
woven polyester mat. Ruberoid a All ron
roofing as well as re- roofing of existing roofs, fired oo to prevent
have adequato.slope and i� with •
ppondiri For fire -rate d by
UL Building Systems Cards and x��rslcpostshall
UL- 790 /ABTM E -108 fire tests. ireconaaaendatioris.
.also Comply with GAF s p lished
1.01 Ruberoid membranes have passed the following tests:
l) UL-- 790 /AST`seo1vL cardsTeets
Class A. B`, • C
2) AccelerT d, ga 3000 hours No deterioration
3) Tensile Strength /Elongation
ASTm lf-azz
Before 'Feathering
'Mdachine Direction
243 lb /2' 4 604
Cross Direction 161 lb /2" - 61%
Alter Weathering
Machine Direction
270 lb /2" w 74%
Cross Direction
175 1b /2" - 72%
ACCEPTANCE No.,$ 91 »0215.4 R
APPROVED • i
EXPIRES • _
P03
1 '. amond, P
roduct Control Division
Supervisor
A9-19791 09:01 AM FROM GAP TPA SALES,.
L�p7�oratinn-
r
ACCEPTANCE No.$
t
APPROVED
EXPIRES
4) Water Vapor Transmission ASTM E -96
Ruberoid MB - Torch applied 0.21
0.75 gms/hr /m
g /h= /aq. m
Mop :Applied 0.1329 g /hx /sq'
5) Heat aging ATM D -573, 2000 hrs.'
70 C.
Tensile Strength /E lon g ation
Machine Direction
Cross Direction
Machine Direction
Cross Direction
6) Wind Uplitt Test ASTM S -330
7) Factory Mutual wind upliftdta.t3
for metal and plywood
g) Factory mutual Mail Damage Test
9) Dimensional Stability ASTM p -1204
Before Weathering
Machine Direction
Cross Direction
Before Weathering
Machine Direction
Cross Direction
•
Before Aging
After Aging
90 lbs /in, 35%
55 lbs /in. 35%
99 1bs /in, 24%
55 lbs /in, 23 %
Passes
X-60 and x -90
Passes
0.4%
0.4%
0.39
. 0.3%
PO4
Gil Diamon P
Product Control Division
Supervisor
. ' 09-19 09:01 Alt FROM GAF TPA SALES
r r
•
•
(N.
.2.00 1dtAtho f Tnatlllatiens
2.01
All installations must comply with the recommendations
io
sa
the manufacturer as described in•their published
and referenced test reports.
2.0?
•-�• This installation is approved without any height
restriction for non- coastal buildings. The concrete deck
is primed with asphalt primer applied at a rate of 1 to 2
p gallons per square. APP membranes are than directly torch
applied to printed deck. In case of SBS membranes, Gafglas
base sheet is solidly hot mopped to primed deck with 2"
e
side and 6" end laps. SBS membrane is then mop-applied
the rate of 25 lbs. per square to the base sheet with 4"
side and 6" end laps.
For coastal areas, the height restriction sh 11 * be 60 feet
for Claes 1, 550 feet for Class 2 and 350 feet for Claps
buildings.
G._A. Cnr�nnrat�nn
rte
• .2.03 Aver Mota1 Daae1
a) The heights shall be limited by types of constrnctior
as defined in the South Florida, Building Code.
b) sga R Mop s
This installation is limited to 550 feet above grade
non-coastalfor
permissible for , e Class not
Class2.and 3 coastal buildings.
p
•
•
.,., np ACCERTAN LI s p RCl Frr Crala rc NS
ACCEPTANCE No.: 91-021k4 R •
APPROVED .1u p 10. 1991____
EXPIRES = March 11. 1994
G D amAnd, P.E.
oduct Control Division
supervisor
P05
0P19 09:01 r AM FROM GAF TPA SALES. . .
•
.•
Approved insulation boards are fasttened t s
deck at the rate of one fasts p
with *12 steel sorew6 and .020" thick 3/ "
diameter coined hexagonal galvanised stee washers.
Gafglas stratavent perforated 6" s he e t is l aidi o a
insulation with 2" aide and rate of Ruberoid
membrane is then hot mopped . a't - the
membrane is then hot - mopped at the rate of 25 lbs.
per square with 4" side and 6' end lap$•
0) lar..2gralLitialissUillarigaw.
This installation is limited to 165 feet above grad*
for non - coastal, 60 feet for C Class 3 coastal
coastal and not
permissible for Class 2 and
buildings. .
Factory Mutual approved eck insulations
Mut�a� PP�ve
fastened to metal d
fasteners at the rate of one fastener per 2 sq. ft.
Gafglas 75.base sheet with 2" sided and i" e n d l
hot mopped to insulation. R
side and 6" end laps is torch applied to base sheet
2.04
The anchor sheet is fastened to theilec with /2 gage.
lea
annular ring - shank steel roofing he16 "mad. atc�a.
the in didetr• Nails deck and be rotrude spaced3as set forth in
the undersi o
de of t he
Table 34 -0 of the South florid& Building Code. d
The nails shall be applied through tin - caps as required
by Section 3403.4 (c) of the South Florida Building Codh
ACCEPTANCE
-2a-
NO. _ , ..�- 0215.4 R
APPRGYXD
EXPIRES
P06
` . Marr1, 11. 1994
09- :19 09:01 AM PROM GAF TPA SALES _
.��►
•
•
/"s
P0?
C°rPtIVattirt ACCEPT'A$CE • No . s
1 APPROVED e
EXPIRES . _ — • - � - 1 —
Ii CS dp SPECIF •
Insulation, base sheet and Ruberoid Membranes shall then
be installed as described in Section 2.03. This
installation is limited to 60 feet above grade for non•
coastal and Class I, coastal defined and
he South Florida further d
by type of construction a
Building, Coda •
2.05 For fire rated roofs, the.Ruberoidmem r�sshall
surfaced with 400 lbs. square O gravel
coat of hot roofing asphalt or coatodwith Karnak No. 97
fibrated aluminum asphalt roof coating oGy
Industries 20F emulsion coating T applies to rate both staootl
specified in O.L. fire tests.
and gravel surfaced APP and SBS membranes. .
2.06 For non -fire ratecoatodswith smoOth
membranes may be aluminum or
applied at a rata of 1
Weather -Coat emulei =n � oaf =anulepaurfaced membrane
to 1 1/2 gallons per guar
need not be coated.
3.00 Work shall be performed only by a licensed roofing contractor,
acceptable to G,A.y.
4.00 Ruberoid membranes can'also be used on exi -up roofs,
provided all loose gravel is removed and all
deteriorated areas are repaired using this a andvth e The the
entire roof covered with this memo an e subject to
use o v
f a l b by th
membrane e product Control Section and in a with
approval by the d
Section 3401•.9 South Florida.Suilding Code.
• lictions for roofing permit must be accompanied by two'
5.00 App
duplicate mete of shop approved pp roved by the architect or
project engineer, along with the manufacturer's .specifications
and standard details. This requirement is waived for re- roofinc
up to 5,000 sq• ft. and single family residential* jobs up to.
5,000 sq. ft. in area.
6.00 '• .This revision supersedes Notice of Acceptance 991 - 0215.4 dated
• $arch 11•.1991.
Gil D @Mond, P.R.
Product-Control Diviaion
.Supervisor •
' = 09- 19 09:01l[ .FROM OAF TPA SALES
. .
•
-•ti
METROPOLITAN DADE COUNTY, FLORIDA
h
• e
• MSTR CENTER
WILDING i SO*NO 01PANIVDET
aio ,
nt N,W, STREET
MIAMI, WSW =54P% • •
(305) 375 -2612•
1. .Extension of Acceptance may be considered after a new
application has been filed and the supporting data, test reports
no older than ten (10) years, have been r*- AXAluated.
A11 reports of re- testing shall bear
h e State se L ori signature and
date of an engineer registered
of
g. Any revision or change in the materials, �nucause facture
the• product or process shall
termination, unless prior approval is granted for reYSsionw or
change:
3. Any Asnratisfactory performance of this product or process or a
• change in Code provisions shall be grounds for
reevaluation. ..., •.
4. . This . acceptance shall not be used an endorsea1ent of any
product !or salsa or advertising pu a ®g
5. 'The Notice of Acceptance number preceded by the words Dade
ion date may the
County, Florida, and followed by the expiration of
• displayed in advertising isplay is then it sha p he done in its
. Notice, of Acceptance
entirety.
where required for permit
6. applications, o nes, shall
ll be provided to the applicant by the
manufacturer or his distributors= unless otherwise .noted in the
Notice of Acceptance. The prints need not be re- sealed by an
engineer. ..
7. , Failure to Comply with Standard Conditions shall bo.cause tor
tdrminatiola of Approval.
•
P08
Gil Diamond,
Product Control Supervisor
Buildingi& Zoning Depart
Building
•.'
METRODADE
TO WHOM IT MAY CONCERN
A: Saniafe' "S" Clay Tile min. slope 2 1/2:12
1: Nail -Set System
• I I
METROPOLITAN DADE COUNTY, FLORI .
METRO•DADE FLAGLER BUILDIN9
DI
BUILDING CODE COMPLIANCE DEPARTMENT
SUITE 160
METRO•DADE FLAOLER BUILDIN9
140 WEST FLAGLER STREE
MIAMI, FLORIDA 33130.156 .
(305) 375.2901
FAX (305) 375.29
Saniafe' Tile Corporation has filed with this office an application with appropriate lest
data to support the approval;of both their Saniafe " 'S" Clay Roof Tile , for Nail & lvfortar -Set
systems, measuring 11" wide by 18" lone and their Saniafe' Mission Barrel Clay Tile, a
Mortar-Set system measuring 7" to 9" by 18" long and both identifie4wilh the imprint
"Ladrillera Santafe' made in Colun►bia ".
August 2, 1993
The tiles shall be installed on a solid nailable deck of 5/8" thick plywood for new
construction or to 1/2" plywood on re- roofing as follows. .
AS FOLLOWS: -
The deck shall be covered with Northern Elastomeric, Inc's.RTU- -100 base sheet as an
underlayment. Each sheet shall be installed with a nominal 3" overlap and tin -cap 12" o.c. in
the field and 6" o.c. at side. At the overlap, the top of the bottom sheet shall be nailed 1 -2" o.c.
along with the bottom of the top sheet with nails off set 6".
A 36" wide strip of RTU -100 shall be Installed at all valleys and nailed 12" o.c. in a line
3 "from each edge. A nominal 16" wide galvanized steel flashing strip shall be provided over
the RTU -100 and nailed 6" o.c. along each edge; with the RTU -J00 applied in the field of roof
to overlap valley flashing 3" and continuously be imbedded in a nominal 3" wide bead of,roofing
cement to the deck ai . the eave.
A nominal 2 "x 2 " galvanized steel drip nailed 4" o.c. shall be provided over the
RTU -100 at the perimeter of the deck and continuously bedded in roofing cement. All nailing
referred above shall be 0.150 diameter, 0.375 diameter head, I" long galvanized steel roofing
nails.
1
SantaJe' Tile Corporation
August 2, 1993
The field tiles maintaining a 2" head lap shall be applied with two 6d galvanized comm
7
i
nails and a noininal 3/4" wide by 3" long bead of Ohio Sealant Inc's RTU -600 adhesive al the
barrel portion head lap. The rake tiles shall be applied with 2 -10d galvanized common nails per
rile installed in 3/16" diameter drilled holes.
The eave tiles shall be closed off with molded closed cell foam eave ship nailed 12" o. c.
incorporating drain holes at the base and at the center of each barrel portion. The application
of this system is acceptable up 10 75 feet above grade.
2: Mortar -Set System
The deck shall be covered with a 3011 Type 11 (ASTMD -226) anchor sheet tin -caped 12"
o. c. in the field and 6" o. c. at the laps. Over this, a hot- mopp4d.90I1..Type 11 (AVM D-249)
granular surface roll roofing cap sheet using hot steep asphalt Type IV conforming to ASTM
D- 319 -89, shall be applied.
The tiles shall be applied with a 2" head lap to the prepared roof deck with mortar
consisting of volumetric proportions of 2.5 to 1 of sand conforming to ASTM C -J44: One bag o
Rinker R6of Tile Cement with approximately.75 gallons of water mixed to a workable
consistency for 2 to .5 minutes.
13: Santare' Mission Barrel Clay Tile
1: Mortar -Set System
• The deck preparation and the mortar used shall be as called out in Section A (2) with the
tile applied maintaining a two inch head lap
Due 10 Hurricane Andrew, this office has been inundated with requests for both new
products and renewals, which has caused a large back log in responding with an official Notice
of Acceptance.
In the interim period, please.accepl these products to be installed by a licensed roofing
contractor in accordance with further instructions and specifications by the manufacturer and
Chapter 34 of the South Florida Building Code and until an official Notice of Acceptance is
issued.
CD: co
PACE2
ice ly ours,
Gil D iumor,
Product Con
Supervisor
on
Santafe Brick and Tile Company
CALL NOW FOB FUH fHEH INFORMATION
TELEFAX: (305) 4745429
u
4R!
is g c.� tt , ; {■
a ;�s��,ty i n
' "fir ; ' ,gv ���ti,,', 044)
4�, alt � y
Santafe Brick and Tile Company
CALL NOW FUH
FUR1HER INFORMATION
TELEfAX: (306) 4745.120
Xousad Lenght• a:; 14i e.
,T nkne'ss+ Naiignal 41
A;BS:Ibs; +fit
r•
.r
�i•, .)':L•ji. i+•r{R,fr(Y77���%i�� � }��7!'t.;t�`�•;'•�,
1
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build-
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address._...(._
State work to be done and purpose of building (by floors)
Street and Number where work is to be done
Building Inspect sr
Registered Architect and /or F neer.
Name and address of licensed contractor
Location and legal description of lot to be built on:
Lot Block Subdivision
Date 7- t/ [t/ 3
No.__/. 1 ___(.___ _ Street_
19
and for no other purpose.
New Building Remodeling Addition Repairs No. of Stories
s 14r-Z9- Ar
To be constructed of Kind of foundation Roof Covering
Estimated Total cost of improvements $__..__ / _ ._ �' Amount of Permit $ —.../.--
Zone cubage required Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be performed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed)
STATE OF FLORIDA,
COUNTY OF DADE. j ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the_
of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are tru
Permit No l/ Date 7 — 5 0 — 3 Read, Sworn to and Subscribed before me.
Disapproved
(Signed)
Notary Public, State of Florida
My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.