Loading...
1201 NE 96 St (6)$ 29.25 MIAMI SHORES VILLAGE APPLICATION FOR BUILDING PERMIT Application is hereby u,nde for the approval of the detailed statement or care plans and specifications herewith submitted for the build • inc or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address . O.UGLAS . Street_46 Registered Architect and /or Engineer vn. err• m•enrnrrerwr• <•n rare. Name and address of licensed contractor SE —GO IND .,�SECUR.ITY W�lgI QW , _51110 .NW 7 2. AVE . Location and legal description of lot to be built on: Lot Block Subdivision ..._....._r...... 1201. NE 96 ST Street Number where work is to be done _ ._._..._...._.._....._.._ .�._.... State work to be done and purpose of building (by floors). • PROPOSE TO Fv,atuz i _ & . ,, SINGLE HUNG, 28 COLONIAL SINGLE HUNG, 1 PICTURE WINDOW:. and for no other purpose. Remodeling XX �• Addition Repairs No. of Stories New Building To be constructed of Kind of foundation Roof Covering Estimate Total cost of improvements $ 5400.00 Amount of Permit $. 2 9 t 2.5 Zone cubage required .Plan Cubage Distance .to next nearest building Size of Building Lot I hereby submit all the plans and specifications for-said building. All notices with reference to the building and its construction may • . SECURITY WINDOWS 5100 NW 72 AVE be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts hislobligations as an employer of labor under the Florida \Vorkmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, anti has complied w ith the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in tkc work to be performed under this permit; and will post or cause to be posted f r inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such abcontractors, of work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed) 'ms ../&4 F..a Mfaxirnum live load to be borne by each floor STATE OF FLORIDA, 1 COUNTY OF DADE. j ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap aY to me well known, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has care fully read the foregoin • • : 'cation, and that he did sign lthe same, and that all facts therein by him stated are true. Permit No...;,;1./ Date 1 7 1 /17 ..._._._ Disapproved PDat (Signed) peared Building Inspector BUILDING INSPECTION DEPARTMENT r , 9 t� ir y Public, State of Florida My Bo u ifest..U1F.. . ...r.»......._.._.:._.....;._.. ONDfU rhR i NS . M ty 'i6 l9 Member $Wita 1 PLANNING BOARD Chairman Mlcrnber Member Member ..... Member ...._ __.L _.....__ Council Approved Date Disapproved i Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A rc•in,pection ice of $1.00 will be charged when such re-inspection is made necessary by improper n for inspection or faulty materials anti /or workmanship. Square Ft. ,Affilr / Signatur of owner and/or Condo President / 0 FEES: PERMIT (pD- RADON 756gi7 PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date ? /o• 9 Job Address / 20/ /f/ 9(, Tax Folio / /" 52 0 / <Y 3 . Legal Description ,/ /L/ /3/4/ /) c /; Owner /Lessee / Tenant Aj7gp / t - o�rt� Owner's Address /20/ � /, 9 `s , Phone Contracting Co. ,Se/Pcr Qualifier /94/ / ° - /S/9 SS# �- Phone 9 I �d ��, (/ / State # ✓ 93aipal # Competency # Ins. Co. Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECH ROO PAVING FENCE SIGN WORK DESCRIPTION AG `/ / /- ?o if/ /ifa of /ti`s C.9 S4' e 7, WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructio ∎ d zoning. Furthermore, I authorize the above -named contractor to do the work stated BALBIR SINGH KANDOLA `'` o � ec. 9 Expu a. CC 520753 Bonded Thnj (Official Notary Omice 1 —(800) 723 - 0121 t , 0 3/9 Dae APPROVED: Zonin Buildin //)11,6 g g si Historically Designated: Yes Master Permit # Address -230/ 4 / 3:-: ' - ; Estimated Cost (value) : ature of Contractor o, Electrical wner- Builder No voyo gWrit. %GO � BALBIR SINGH KANI)OI,AI k a"tit ri i999 xptreMo. CC 520753 Bonded Thru (Official Notary em I—(800)723-0121 at ate 3O � o C.C.F. / . NOTARY E OND TOTAL DUE Mechanical Plumbing Engineering Job Address: /xf 9t' $ Contractor ° .._74l / Process No. l2aol -168 W94 Base Sheet: Fasteners: APPENDIX 'E' METRO -DADE UNIFORM BUILDING PERMIT SECTION II BUILT -UP APPLICATIONS AND MODIFIED BITUMEN SYSTEMS GENERAL: Type of Roof System Assembly to be Applied: Manufacturer of Roof System Assembly: Product Control Approval Number: System Number from Product Control Approval: Complete the following for all Roof System Assemblies: Built -Up Applications and Modified Bitumen Systems Page -1 95 (Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System Guide Specification. ) ( Note: If a minimum roof system is to be applied, describe all components within the system and list the manufacturer of each component. DO NOT complete this section if system is Product Control Approved. ) Ply Sheet(s): . Cap Sheet: Asphalt: ( Note: No insulation system is acceptable under the minimum roof category. ) Job Address: ( Check . one of the following) Recover Re -roof: If a recover, is the existing Roof System Assembly to be used as a bonding substrate ?: If YES, has an ASTM E907 test been carried out to confirm adhesion of the existing membrane to the substrate ?: (If 'yes', attach ASTM E907 test report. ) Proposed Fastener: (Attach withdrawal resistance test report. ) Has the deck been examined for moisture ?: Y N (Provide data confirming compliance with Section 3401.9(c) . ) THE SYSTEM: All Roof System Assemblies in the Product Approval have a variety of options. Briefly describe the Roofing Components to be used in the Roof System Assembly and attach a copy of the manufacturer's published specification: Deck: ( Briefly describe ) Insulation: (Type, size and method of attachment, if applicable ) Base Sheet or Ply: ( Type and method of attachment ) Ply Sheet(s): ( Type and method of attachment ) Contractor 60 00 i New Construction Process No. a, „ Built -Up Applications and Modified Bitumen Systems Page -2 Job Address: Contractor Process No. Top Ply: (Type and method oj attachment ) Surfacing: (Type, if applicable ) Flashing Materials: ( Type and method of attachment ) k/r,a0 Built -Up Applications and Modified Bitumen Systems Pagc -3 Job Address: Contractor Built -Up Applications and Modified Bitumen Systems Page -4 Process No. inches T I _ inches T inches FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND INSULATION LAYER(S). (Where Roofing Component not used in Roof System Assembly, fill in with "N /A ".) Sur facing: (M t ty 4sr ►. i • op Ply '7.3 n Bonding Mat �n( Ply Sheet(s): a 61 Bonding Material: Fastener: 1 f /4 *1 I T I (VJbare sheet neck ono re Base Sheet: r i Bonding Material: ((lban sheer bonded ) Fastener: � — Bonding Material: (if,op emulation layer bonded ) Fastener: ((/innlanan neeh. orroched) Insulation: Bonding Material: ({/ 4wLnon bonded ) � Vapor R etarder. (pgppleab Primer. (U•ppbcm) DECK: JQ Type: L Zfi l Qt2Q (((top rnnlonon toyer meek onachrd) Top Insulation Layer: (/oppheable) Gage or Thickness: Density. if concrete deck: Job Address: Contractor PERIMETER DETAIL #1: Parapet Wall Detail Coping Cap Gage: Fastener Spacing: _ o.c. Clip Type: Clip Gage: Sketch Roofing Components which make up Roof System Assembly at Perimeter Parapet Walls. Insert leaden indicating Roofing Component Hama, dirnatsions, thicknesses, etc Include fastener type and spacing used for wood- blocking attachment. Deck Type: Sketch Roofing Components which make up Roof System Assembly at Perimeter Areas to be Flashed. Insert leaders indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. PERIMETER DETAIL #2: Flashing Detail Built -Up Applications and Modified Bitumen Systems Page -5 Process No. Job Address: Contractor PERIMETER DETAIL #3: Gravel Stop or Drip Edge Process No. Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Gravel Stop or Drip Edge. Insert leaden indicating Roofing Components names, dimensions, thickneuea, etc. Include fastener type and spacing used for wood- Wading attachment Gavel =Edge Edge Gage: Fastener 1- , I 0 Spacing: ` o.c. Clip Type: Clip Gage: Deck Type: 1/V)12 Sketch Roofing Components which make up Roof System Assembly at Perimeter Edge with Guners. Insert leaden indicating Roofing Component names, dimensions, thicknesses, etc. Include fastener type and spacing used for wood - blocking attachment. Gutter Type: Gutter Gage: Fastener Spacing: \f\fr Deck Type: PERIMETER DETAIL #4: Gutter Detail Built -Up Applications and Modified Bitumen Systems Page -6 Job Address: Contractor Process No. Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may exisit Insert leaders indicating Roofing Component names, dimensions, thickrsses, etc. Include fastener t and spacing used for wood - blocking attach:. _ PERIMETER DETAIL #5: 'Other' Detail Sketch Roofing Components which make up Roof System Assembly at any 'other' Perimeter Condition which may exisit Insert leaders indicating Roofing Coruponent names, dimensions, thickesses, etc Include fastener type and spacing used for wood - blocking attachment PERIMETER DETAIL #6: 'Other' Detail Built -Up Applications and Modified Bitumen Systems Page -7 Job Address: Contractor Process No. 110►. Insert Building and Parapet Heights. (!f no Parapet exists. insert ?J/A") Also insert applicable information pertaining to the building below. (See ASCE 7 -88 Fact Sheet Attached) Exposure Category Classification Category: Al Hurricane Oceanline ?: Y N Basic Wind Speed at Building Location: l 10 mph Building Condition based on % of Openings: GROUND LEVEL feet feet BUILDING INFORMATION #1 Built -Up Applications and Modified Bitumen Systems Page -8 Job Address: Contractor Process No. Sketch Roof Plan indicating all dimensions, any slopes, roof drains. crickets, or roof top equipment. Also insert variable labeled "a" which indicates perimeter and comer dimensions per Chapter 23 of the South Florida Building Code. ( See ASCE 7 -88 Fact Sheet Attached ) BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions Built -Up Applications and Modified Bitumen Systems Page -9 Job Address: Contractor Process No. a — FOR PLAN EXAMINER USE ONLY — Roof System Assembly Product Control Approved: Y N If NO, note any deficiencies: Design Pressure Requirements: Field: psf Perimeter Areas: psf Corner Areas: psf Note any limitations: Reviewed Details ?: Y N Notes: Built -Up Applications and Modified Bitumen Systems Page -10 V Job Address: Contractor Process No. Reviewed Field Test Data ?: Notes: Additional Notes: Built -Up Applications and Modified Bitumen Systems Page -11 Y N Plan Examiner MEMO-DADE MIN EXPIRES: 11/10/97 APPROVED: J!3/14/96 ()Jar.") a 13010 r Auso.A-74ec, BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING ' 140 WEST FLAGLER STREET 1 tOJ) UCH' CONTROL NOTICE OF ACCEPTANCE' MIAMI, FLORIDA. 133130 -1563 GAF Materials Corporation (305) 375 -2901 FAX (305) 375 -2908 1361 Alps Road INTERNET: mdcc01@shadow.net Wayne, NJ 07470 Your application for Product Approval of: PRODUCT CONTROL SECTION (305) 375 -2902 GAF Conventional Built -Up Roof Systems FAX (305) 372 -6339 under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: I)yuatecli Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -98 and the standard conditions on page 99. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing.. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or Material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incyt`i by the manufacturer. ACCEI'TANCE NO.: 95- 1003:3/ Revises No.: 94- 1014.01 1 METROPOLITAN DADE COUNTY, FLORIDA METRO -DADE FLAIGLER BUILDING aul Rodriguez Product Control Division Supervisor iliaanLESABIERSHEELIEELAWaThEIALXAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product-Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in D County, Florida under the conditions set forth above. arles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County • GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 CaleeotX: Membrane Roofing System Su_b Catc_;ory1 Built -Up Roofing Tvpe: Conventional Sub- [yp Fiberglass PRODUCr CONTROL NOTICE OF ACCEPTANCE ROOTING SYSTEM APPROVAL Product Control No.: 95- 1003.03 Product Control No.: 95- 1003.03 Approval Date: March 14. 1996 Expiration Date: Nov. 10. 1997 System Description, GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years, produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition, GAF offers two ply modified systems to meet the demands for multi -ply SBS and APP modified specifications. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained front GAF and can be found in the "GAFGLAS Built -Up Roofing Application and Specifications" manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material Directory and the current Factory Mutual Approval Guide. GAF Materials Corporation products are distributed through a wide network of roofing dis!ributors throughout the South Florida area. Contact: William J. Woodring Director of Technical Services (201) 628-4134 2 wholesale For more information on specific roof system constructions, contact the Technical Service Office, located in Wayne, New Jersey, at 1- 800 - ROOF -411. . 1115 /1 0 Frank Zuloaga �� Plans Examiner, ‚1 'c ontrol Division 111 ll al n Iy12 €S: Material Basalt Wool l'erlite Polyisocyanurate Composite Board Wood Fiberboard High Density Wood Fiberboard Rockwool Maximum Design Pressure Wood -60 psf Steel -75 psf Concrete -192 psf Lightweight Concrete -45 psf Ceinentitiotfs Wood Fiber -45 psf Poured Gypsum Concrete -45 psf Maximum Fire Classification Design Pressure Magill • Classification Wood Class 'A' Steel Class 'A' Concrete Class 'A' Lightweight Concrete Class 'A' Cementitious Wood Fiber Class 'A' Poured Gypsum Concrete Class 'A' Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory for Fire Classifications. Frank Zuloaga Plans Examiner, 3 Product Control No.: 95- 1003.03 ontrol Division Test Product Product Dimensions Specification Description GAF Materials 5,'55 gallons ASTM D 41 Asphalt concrete primer used t Corporation Asphalt promote adhesion of asphalt in Concrete Primer roofing. Granules TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT • GAF Materials Corporation Jetblak All Weather lylastic Cement . GAF Materials Corporation Plastic Cement . GAF Materials 5 gallons Corporation WeatherCoat® Emulsion GAF Materials 1, 5 gallons Corporation Fibered Aluminum Coating GAF Materials 1, 5 gallons ASTM D 3019 Corporation Jetblak ASTM D 3409 All Weather Plastic Cement GAFGLAS #75® 3' x 108' ASTM D 4601 Base Sheet 75 lb. roll GAFGLAS Ply 4 3' x 180' ASTM D 2178 40 lb. roll ASTM D 2824 Fibered aluminum coating. Frank Zuloaga Plans Examine 4 Product Control No.: 95- 1003.03 - — ontro uilt -up GAF Mineral Shield® 60 Ib. bags ASTM D 1863 Granules for surfacing of exposed asphalt, cold process cement or il emulsion. GAF Mineral Shield® Granul shall be used for flashing applications only. 1, 5 gallons ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. 1, 5, 53 gallons ASTM D 4586 Trowel grade, asphalt plastic cement. ASTM 1227 Surface coating for smooth surfaced roofs. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. Asphalt impregnated and coated glass mat base sheet. GAFGLAS Ply 6® 3' x 180' ASTM D 2178 Type VI asphalt impregnated glass felt 45 Ib. roll with asphalt coating. Type IV asphalt impregnated glass.felt with asphalt coatin 'f } Prodtie.I GAFGLAS® Mineral Surfaced Cap Sheet GAFGLAS® 3' x 36" Stratavent® (Vent 691b. roll Ply) for nailable decks GAFGLAS® Flashing various GAFGLAS® 3' x 36" Stratavent® (Vent 60 Ib.• roll Ply) Perforated GAFTEMP® Isotherm . R GAFTEMP® Composite GAFTEMP® Fiberboard GAFTEMP® Permalitee GAFTEMP® High Density Fiberboard GAFTITE® 1112 Standard Roofing Fastener GAFTITE® #I4 !Leavy Duty Roofing Fastener GAFTITE® Base Sheet Fastener and Plate Dimensiosts 3' x 36' 76 Ib. roll various various various various various Test S.Imikation ASTM D 3909 ASTM D 4897 D 3672 PA 110 PA 114 PA 114 Product Control No.: 95- 1003.03 Product Description Asphalt coated, glass fiber mat cap sheet surfaced with tnineral granules. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Proprietary Asphalt coated glass fiber mat flashing sheet available in three sizes. ASTM D 4897 Fiber glass base sheet impregnated and D 3672 coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Polyisocyanurate foam insulation. PA 110 Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Fiberboard insulation. PA 110 Perlite insulation board. PA 110 High density wood fiberboard insulation. Insulation fastener for steel and plywood decks. PA 114 Insulation fastener for steel, wood and concrete decks. Base sheet fastening assembly. Frank Zuloaga n ri'•_ 'r trot 1 ivi • Plans Exanu e , 5 NTB Fasteners PA 114 Polypropylene Plates 3" and 3 Vi" PA 1 14 Ruberoid® 20 1.5 sq. roll ASTM D 5147 Ruberoid® Mop 1 sq. roll Granule 103 lbs. ASTM D 5147 Frank Zuloaga Plans Examiner, 6 Product Control No.: Test Product Product Dimensions Specification Description Galvalume Plates 3" and 3 %2" PA 114 Round galvalume stress plates Fastener for use in gypsum, tectum and lightweight insulating concrete decks. Round polypropylene stress plates. SBS modified asphalt base sheet reinforce with a glass fiber mat. 95- 1003.03 Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Vent Stacks (metal PA 100(A) One way valve vent used to relieve and plastic) ASTM D 1929 built -up pressure within the roof system. ' ASTM D 635 GAF Vent Stacks are available in metal or plastic. ontrol Division Product I'yrox ACFoam 1 ACFoam 11 Celcore Test Product Dimensions Specification Description various PA 110 various PA 110 various PA 110 PA 110 I {y -Therm Nail -line various PA 110 1-ly -Therm SP various PA 110 Fly-Therm AP various PA 110 lly -Therm Stable It various I'A 110 fly -Therm White various PA 110 Line VaporBar GB Anchorbond PA 114 Fastener I)ekfast Fasteners 1114 TRADE NAMES OF PRODUCT'S MANUFACTURED BY OTHERS PA 114 Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Cellular insulating concrete system Polyisocyanurate foam insulation Polyisocyanurate foam insulation. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation 36" x 108' ASTM D 4601 G2 fiberglas base sheet Insulation fastening assembly Insulation fastener for steel and concrete decks Product Control No.: 95- 1003.03 Manufacturer Apache Products Co. (with current PCA) Atlas Energy Products (with current PCA) Atlas Energy Products (with current PCA) Celcore, Inc. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp.' , (with current PCA) Celotex Corp. (with current Celotex Corp. (with current 1 CA) CA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Construction Fasteners Inc. Frank Zuloaga Plans Examine ontrol a i 7 Rio' • &QdW1 Dimensions Dekfast ilex Plate 2 7/8" x 3 1/4" Dekfast Lock Plate 3" x 3 1/4" Dekfast Fasteners #15 Dekfast Fasteners 11 12 TPR Elastizell FM -30, FM-45, FM -60, FM -90 Fasteners Nail -Tite Type 'A' Nail -rite Type 'R' ISO 95+ Composite Test Product Specification Description PA 114 Galvalume hex stress plate. Construction Fasteners Inc. (with current PCA) PA 114 PA 114 PA 114 PA 114 PA 110 PA 114 PA 114 PA 114 PA 110 Polypropylene locking plate. Insulation fasteners for concrete decks Insulation fastener for steel and wood decks. Aluminum fastener for lightweight, gypsum and tectum decks Cellular insulating concrete system Base ply fastening systems for lightweight concrete decks Galvanized steel base ply fastener for lightweight concrete decks Galvanized steel base ply fastener for lightweight concrete decks Polyisocyanurate / perlite ridged insulation Frank Zuloaga Plans Examiner, 8 Product Control No.: 95- 1003.03 Manufacturer Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) Creative Construction Components (with current PCA) Elastizell Corp. (with current PCA) ES Products (with curren ES Products (with curren Inc. PCA) Cnc. PCA) ES Products, Inc. _ (with current PCA) Firestone (with current PCA) ontrol Divisio • Pjoduct Asphalt Asphalt Primer El'S Perlite Insulation Polyethylene Rcd Rosin Test Product Dimensions Specification Description various Iligh Density Wood various Fiberboard Oriented Strand various Board Pelite /Urethane various Composite' Rooting Nails Tin Caps Type X Gypsum various Type X Gypsum various al MB aluminum roof coating Dcns -Deck various various PA 110 4 mil min. various Minimum # PAI 14 12 Min. 32 ga. x 1 5 4 1 Product Control No.: 95- 1003.03 Manufacturer ASTM D 312 Type 111 or IV Ilot asphalt generic bitumen adhesive Asphalt Primer PA 110 Extruded polystyrene insulation PA 110 Wood fiber insulation board PA 110 Oriented strand board ASTM D 41 PA 110 generic generic generic generic Perlite / urethane composite generic board insulation Perlite insulation board generic Vapor barrier / Air barrier generic Rosin paper for barrier layer on wood decks generic Corrosion resistant annular generic ring shank nails Corrosion resistant circular generic discs. Fire resistant rated gypsum generic Fire resistant rated gypsum generic PA 121 Aluminum roof coating Grundy Industries (with current PCA) PA 110 Gypsurn insulation board. Georgia Pac frc Frank Zuloaga Plans Examiner, 9 ontrol Drvisi • Product 1112 Roofgrip I/14 Roofgrip Gripdek Fastener I- lexcel Fastener 1-lextra PA 114 Standard Plastic Plate ISO 95 + E'NRG'Y -2 1SORoc Con -Cite N.T.B. Magnum Test Product Dimensions Specification Description 3" round PA 114 various PA 110 various PA 110 various PA 110 PA 114 PA 114 PA 114 insulation fastener for steel ITW Buildex • or wood decks • (with current PCA) PA 114 Insulation fastener steel, ITW Buildex • wood or concrete decks (with current PCA) PA 114 PA 114 Insulation fastener Insulation fastener Insulation fastener and metal or plastic plate Polyolefin plastic plate Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam / rockwool composite insulation Concrete deck insulation fastener Glass reinforced nylon fastener for use in gypsum and cementitious wood fiber decks. Frank Zuloaga Plans Examiner, 10 Product Control No.: 95- 1003.03 Manufacturer ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) International Permalite (with current PCA) NRG Barriers, Inc. (with current PCA) NRG Barriers, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) • L ontrol Divistot riosli!c.t Dimensions N.T.B. Spin 2" round Weld Plate N.T.B. Plastic Plate 3" round N.T.B. Plate Olympic Standard 3" round Olympic Fastener #I4 Olympic Polypropylene Olympic Fastener #12 Olympic Fastener Test Specification PA 114 PA 114 PA 114 PA 114 PA 114 3.25" round PA 114 PA 114 PA 114 Product Description 2" round amorphorus nylon locking plate for use with N.T.B. fasteners with 1" head 3" round polypropylene stress plate for use with N.T.B. fasteners 3" round galvalume AZ55 plate for use with N.T.B. fasteners 3" round galvalume AZ55 steel plate Insulation fastener Polypropylene plastic plate Insulation fastener Insulation fastener Frank Zuloaga Plans Examiner, Il Product Control No.: 95- 1003.03 — Manufacturer Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) ontrol Division P thi 1 Olympic CR Base Felt Fastener and Base Sheet Disc Test Product Dimensions Specification Description PA 114 GlasFast Fastener PA 114 GlasFast/Striker PA 114 Paroc Base Board various PA 110 • I'aroc Cap Board various PA 110 Multi -Max various PA 110 Multi -Max FA 'various PA 110 UltraGard various PA 110 lnsul -Fixx Fastener Insul -Fixx P Rawl Drive PA 114 3" round PA 114 PA 114 Insulation fastener Assembly for Base Sheet fastening only Insulation fastener assembly with recessed plastic plate Insulation fastener assembly and metal plate for use over concrete decks Rockwool insulation Rockwool insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Insulation fastener for steel and wood decks 3" round polyethylene stress plate Insulation fastener and steel and plastic stress plate for concrete deck Frank Zuloaga Plans Examiner, 12 Product Control No.: 95-1003.03 Manu facturer Olympic Manufacturing Group, Inc. (with current PCA) Owens- Corning Fiberglas Corp. (with current PCA) Owens - Corning Fiberglas Corp. (with current PCA) Partek, Inc. (with current PCA) Partek, Inc. (with current PCA) Rmax, Inc. (with curren PCA) Rmax, Inc. (with current PCA) Schul ler International Inc. (with current PCA) SFS /Stadler (with current PCA) SFS /Stadler (with current PCA) The Rawlplug Company Inc. (with current PCA) ontrol Divis Produci Rawl Fasteners �t 12 Rawl Fasteners 11 14 Rawl 2" Plate 2" round Rawl 3" Plate 3" round Rawl Spike Rawlite Rawlite 3" Plate 3" round 202 HS Super Prep II Tru -Fast DL Test Dimensions Specification PA 114 Insulation fastener for steel The Rawlplug and wood decks Company Inc. (with current PCA) PA 114 PA 114 2" round galvalume AZ55 The Rawlplug membrane plate Company Inc, (with current 'PCA) ' PA 114 3" round galvalume AZ55 The Rawlplug steel plate Company Inc. (with current PCA) PA 114 Insulation fastener and steel The Rawlplug and plastic stress plate for Company [no concrete deck (with current'. PCA) PA 114 PA 114 PA 121 PA 121 — Product Description Manufacturer Insulation fastener for use in steel, wood or concrete Insulation fastener for cementitious and gypsum decks 3" round galvalume AZ55 steel plate for use with Rawlite fasteners Roof coating Roof coating Product Control No.: 95- 1003.03 The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) Thermo - Materials, Inc. (with current PCA) Thermo- Materials, _ Inc. (with current PCA) PA 114 Insulation fastener for steel, Tru -Fast or wood (with current PCA) Frank Zuloaga Plans Examiner, 13 ontrol Division Product Dimensions Tru -Fast Plastic 3.04" round PA 114 Plate Tru -Fast MP -3 3.23" round PA 114 Tru -Fast 1-ID PA 114 Tru -Fast Ultra PA 114 Tru -Fast TL Tru -Fast .DP Tru -Fast TP Tru -Fast CF Fasteners • Insulcel Structodeck Test . ap eifcatiort PA 114 PA 114 PA 114 PA 114 PA 110 various PA 110 Product Description 3.04" round polyethylene plastic plate 3.23" round galvalume • AZ50 steel plate Insulation fastener for use in wood, steel or concrete decks Stainless Steel fastener for use in steel, wood and concrete decks Glass reinforced nylon fastener for use in tectum or gypsum decks Insulation fastener for use in steel or wood decks Insulation fastener for use in steel or wood decks Insulation fastener for concrete decks Cellular insulating concrete system High density wood fiber Frank Zuloaga Plans Examiner' ••"fi 14 Product Control No.: 95- 1003.03 Manufacturer Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with curren PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) W.R. Grace . (with current PCA) Wood Fiber Industries (with current PCA) is ontrol Division • :Lot Agency /Identifier Factory Mutual Research Corporation Underwriters Laboratories, Inc. Y Dynatech Engineering, Inc. Name FMRC 1994 J.I. #OT4A LAM J.I. # I V8A4.AM J.1. #IRIA6.AM J.I. #0T2Q4.AM J.I. #0Q6A6.AM J.I. #3X3A2.AM J.1. #0Y9Q5.AM ' R1306, 87NK1 1819 3600.02.95 4482.02.95 Test Reports Report Current Insulation Fastening Requirements Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Class A Fire Classification Wind Uplift, Small Scale Wind Uplift Frank Zuloaga Plans Examiner 15 Product Control No.: 95- 1003.03 Date 01.01.94 08.26.92 06.28.93 11.15.91 10.17.91 07.16.91 08.02.94 07.29.94 01.01.93 02.02.95 02.02.95 Deck Type 1: Deck Description: System Type A(1): Base Sheet: Ply Sheet: Cap Sheet: Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: Wood, Non - insulated 19 4 2 " or greater plywood or wood plank decks Base sheet mechanically fastened. MI General and System Limitations shall apply. Product Control No. 95- 1003.03 GAFGLAS® 475, GAFGLAS® PLY 6 ®, GAFGLAS® STRATAVENT® or RUBEROID® 20 applied to the deck with approved annular ring shank nails and minimum 1 5 4" tin caps at a fastener spacing of 12" o.c. at the lap, 18" o.c. in two rows staggered along the center line of the sheet in the field. Two or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 IbsJsq.. (Required if no cap sheet is used) Install one of the following: 1. Grundy AL MB aluminum Roof Coating with an application rate of 1.5 gal /sq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal./sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbsJsq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbsisq., respectively. -45 psf. 'A'. See General Limitation #2. 3 ":12 "; See General Limitation #3. N- B -3 -C, N- B -3 -G NFB -4 -M, N- B- 4M /P6, N- B -4 -C, N- B- 4 -C /P6, N- B -4 -G, N- B- 4 -G/PG, N- B -5 -C, N- B- 5 -C/P6, N- 13-S -C, N- B- 5 -C/P6, N- B -5 -G, N- 13- 5 -G /P6, N- B -5 -M, N- B- S -M/P6 Frank Zuloaga Plans Examiner, 26 • . uct Control Division a. Deck Type: " /, Plywood. Product Control No.: 95- 1003.03 Wood Deck System Limitations: 1. A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to plank and deck. Red rosin sheet may also be installed on plywood decks as an option. 2. A slip sheet is required with GAFGLAS® PLY 4 and PLY 6® when used as a mechanically fastened base or anchor sheet. 3. Pre - assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. Pre - assembled 'Cap Nail' shall not be used for base sheet attachment. 4.* The following assembly is approved to a maximum design pressure of -52 psf. No substitutions shall be made: b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet, GAFGLAS® Ply 60, or STRATAVENT® (Vent Ply) for nailable decks, or RUBEROID® 20 base sheet. Fastening: Nailed 9" o.c. at the lap and in two tows staggered 18" in the field, nailed with 11 ga. annular ring shank nails and 1 s /," tin caps. c. Insulation: Base Layer: (Optional) Min. 1.2" E'NRG'Y 2, 2 Plus, AC Foam 1, 11 or GAFTEMP Isotherm R adhered to the Anchor Sheet in a full mopping of approved asphalt applied within the EVT range at a rate of 20 -40 lbs. /sq.. Top Layer: Min. '' /s" approved wood fiberboard adhered to the base insulation layer in a full mopping of approved asphalt applied within the EVT range at a rate of 20 -40 lbsisq.. d. Base Sheet: (Optional) Install one ply of GAFGLAS® 475 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. e. Ply Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved asphalt applied within the EVT range an Frank Zuloaga Plans Examine 28 • g. a. Deck Type: ' Plywood. 20 lb/sq.; or Grundy AL M an application rate of 1.5 Frank Zuloaga Plans Examine 29 1. tr0 • • Product Control No.: 95- 1003.03 f. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Surfacing: (Optional) Install one of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lb. /sq.; or Grundy AL MB aluminum Roof Coating with an application rate of 1.5 galisq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal/sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 •Ibsisq. f 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbsisq., respectively. 5. The following assembly is approved to a maximum design pressure of -52 psf. No substitutions shall be made: b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet, GAFGLAS® Ply 60, or STRATAVENT® (Vent Ply) for Nailable decks, or RUBEROID® 20 base sheet. Fastening: 9" o.c. at the lap and in two rows staggered 18" in the field with GAFTITE® insulation screws and steel stress plates. c. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 Ibs.sq.. d. Ply Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. e. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. f. Surfacing: (Required if no cap sheet is used) 'Install one of the following: I. GAF Special Roofing Bitumen with an application rate of .1 •.:.. .. .... with or G WEATHE Product Control No.: 95- 1003.03 COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or slag with an .application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. *Note: The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners, and corners). Frank Zuloaga Plans Examine `control Divisio 30 General Limitations: Application. Frank Zuloaga Plans Examine 97 Product Control No. 95- 1003.03 1. All asphalt shall comply with ASTM D 312 type III or type IV requirements. All proposed asphalt producers must be approved by the applicant. 2. Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3. Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4. An overlay /recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq.. Note maximum design pressure restrictions on spot attached systems. 5. All work shall be performed by a contractor licensed to do roofing work in Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer. • 6. In re- roofing applications, moisture content in an existing roof must be in 'compliance with Section 3401.10(m), (n) of the South Florida Building Code. 7. Prior to application, all existing roof surfaces used as a bonding substrate shall be tested for uplift resistance in compliance with Dade County Protocol PA 124 to the calculated design pressure of the roof deck. 8. If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 9. Perimeter and corner areas shall have an increase in fastener density for both insulation and base sheet in compliance with Dade County Protocol PA 117 of the South Florida Building Code. 10. All attachment and sizing of perimeter nailers and metal profile designs shall conform with Dade County Protocol PA 1 1 1 of the South Florida Building Code. I I. Flaslrings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be sub ?C metro r • _ 12. Roll good materials shall be stored on end and on a clean, flat and dry surface. 13. Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with Chapter 3401.5 and 340.1.6 of the South Florida Building Code for maximum fire classification. 14. Asphalt moppings shall be with applied with asphalt approved by the applicant and shall be approved in compliance with equiviscous temperature (EVT) methods of asphalt deterniination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 15. Insulation may be installed in multiple layers. . The first layer shall be attached in compliance with Product Control Approval guidelines. All other layer's shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs./sq., or mechanically attached using the fastening pattern) of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive. 16. Pre - assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. 17. The submission of system specifications and details shall accompany the Section 1I Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 18. All standard panel sizes are acceptable for mechanical attachment. When approved asphalt, panel size shall be 4' x 4' maximum. 19. Fastener spacing for insulation attachment is based on a minimum withdrawal resistance value of 275 Ibf. as tested in compliance with PA 105. If the fastener value, as field tested, are below 275 Ibf. insulation attachment shall not be acceptable. Frank Zuloaga Plans Examiner, 98 •■■Allio A 4 , 0 IIIIIIN.- ..1111 ontrol I iv Product Control No.: 95- 100103 applied in GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 5. Product Control No.: 95- 1003.03 ACCEPTANCE NO.: 95- 1003.03 APPROVED : March 14. 199G EXPIRES : -Nov. 10. 1997 I IQTICE OF ACCEPTANCE STANDARD CONDITIONS 1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original subtnitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3. Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, ► including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted , is no longer practicing the engineering profession. 4. Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6. The Notice of Acceptance nuniber preceded by the words Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the rnanufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9. This Acceptance contains pages I through 99 . END OF THIS ACCEPTANCE Frank Zuloaga Plans Exanriner,Ztro 1 • . 99 �„ .. 214 ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS. (TGFU)—Continued Surfacing: "Gacoflex UA -85 ", applied at 1 gaV sq. (12 dry mils). 39. Deck: NC Incline: 1 -1/2 Foam: "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat One or two applications "Gacoflex UB- 6499 ", applied at 1.2 gaVsq. per applica- tion (14 -28 dry mils). Surfacing: "Gacoflex A- 55000 ", applied at 1 -1/2 gaV sq. (14 dry mils). 40. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Top Coat Two Applications "Ure -Cap 88" Series coating (various colors) applied at 1.3/8 gaV sq /application or 3 applications applied 1 -1/4 gaVsq/application. Top Coat (Optional): One application of "Gacoflex UA -65" Series (various colors) applied at 1 gal /sq or "Gacoflex UA-60" applied at 1 -1/4 gaVsq (12 dry mils). 41. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam 303", 1 in. min. Base Coat One or two applications "Gacoflex UB -64 ", 1 gal /sq /application (12 -24 dry mils). Surfacing: "Gacoflex UA -65" Series 1 gal /sq or "Gacoflex UA -60" applied at 1 -1/4 gal /sq (12 dry mils). 42. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or 3 applications applied 1-1/4 gal /sq /application (16-32 dry mils). Surfacing: "Gacoflex UA-65" Series (various colors) applied 1 gal /sq (12 dry mils). 43. Deck: NC Incline: 1/2 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or " Polyfoam 303 ", 1 in. min. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or 3 applications applied 1-1/4 gal /sq /application (16-32 dry mils). Surfacing: "Gacoflex UA -60" Series (various colors) applied 1 gal /sq (15 dry mils). 44. Deck: NC Incline: 2 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat "GacoSil S- 1000" applied at 1 gaVsq (10 dry mils). Surfacing: "Gacoflex S- 1000" applied at 1 gal /sq (10 dry mils). 45. Deck: NC Incline: 1 Foam: " Polyfoam 251" or " Polyfoam 303 ", any thickness. Surfacing: "Gacoflex Ure- Shield 7007", 40 dry mils. GAF MATERIALS CORP, WAYNE NJ 07470 R1306 (N) " RUBEROID 20" or "RUBEROID Mod Base 30" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet (" GAFGLAS #75 Base Sheet") is a suitable alternate for Type G1 asphalt glass fiber ply sheet (" GAFGLAS Ply 4" or "GAFGLAS Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAFGLAS Stre- tavent (Vent -Ply) perforated" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be mechanically' attached granule side down. As an option Type G2 asphalt glass mat base sheet (' GAFGLAS #75 Base Sheet" or " GAFGLAS Stratavent (Vent -Ply) for nailable decks ") may be subsituted for G1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. " GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C sys- tems listed below. When "perlite" is referenced, this includes " GAFTEMP Perlite" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems list- ed. Structural cement fiber building units are considered suitable to be included as a deck in the fol- lowing Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin Pa per (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the fol- lowing Class A, B or C systems. "GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP Composite A" may be substituted for any isocyanurate insulation in any of the following Classifications. Class A. B and C. Hot roofing asphalt, for use with organic pnd glass felts or modified bitumen membranes. Class A 1. Deck: C -15/32 . Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Deck: C -15/32 incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type G1 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". ROOFING SYSTEMS (TGFU)— Continued Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber. glass fiber, isocyanurate, ure- thane, perlite/isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, 2 in. max. ply Sheet Two or more layers Type 61 "GAFGLAS Ply 4" or "GAFGLAS Ply 6". Cap Sheet One layer Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ". Deck: NC Incline: 1/2 Insulation One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. fly Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet One layer of Type G2 " GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet One or more layers of Type G1 " GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cep Sheet One layer of Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ". 8 , Deck NC Incline: 3 Base Sheet One layer of Type G2 " GAFGLAS #75 Base Sheet ". Ply Sheet One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet One layer of Type G -3 " GAFGLAS Mineral Surfaced Cap Sheet ". 7. Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1.0 in. min (off -set from plywood joints 6 in.). ,Base Sheet One or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet Two.or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type G1. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Class B 1. Deck: C -15/32 Incline: 3.1/2 Insulation (Optional)- One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite/isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic. any thickness. Ply Sheet Two or more layers of Type 61 " GAFGLAS Ply 4" or " GAFGLAS Ply 6" Cep Sheet Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. 2. Deck: C -15/32 Incline: 3 -1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate. ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet Two or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Class C 1. Deck C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber. isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood finer /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ". Surfacing: "Special Roofing Bitumen" 20 Ibs /sq. COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR Class A I. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", hot mopped with coal tar bitumen. Surfacing: Gravel. COMBINATION 140T AND COLD SYSTEMS Class A I. Deck: NC Incline: 2 Insulation (Optional): One or mere layers perlite, wood fiber or glass fiber, 2 in. max. Ply Sheet Three or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: Grundy Industries "al MB Aluminum Roof Coating" at 1 -1/2 gal /so. 2. Deck: NC Incline: 1 Insulation (Optional) One or more layers perlite, wood fiber. glass fiber, isocyanurate. ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Weather Coat.Emulsion" at 3 gal /sq. 3 . Deck NC • Incline: 1/2 Insulation: One or two layers "Isotherm R", 4 in., hot mopped. Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. Class B 1, Deleted. 2 . Deck C -15/32 Incline: 2 fiber nlass fiber. isocyanurate, ure- 8. ROOF COVERING MATERIALS (TEVT) 215