1201 NE 96 St (6)$ 29.25
MIAMI SHORES VILLAGE
APPLICATION FOR BUILDING PERMIT
Application is hereby u,nde for the approval of the detailed statement or care plans and specifications herewith submitted for the build •
inc or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
Owner's Name and Address . O.UGLAS . Street_46
Registered Architect and /or Engineer vn. err• m•enrnrrerwr• <•n rare.
Name and address of licensed contractor
SE —GO IND .,�SECUR.ITY W�lgI QW , _51110 .NW 7 2. AVE .
Location and legal description of lot to be built on:
Lot Block Subdivision ..._....._r......
1201. NE 96 ST
Street Number where work is to be done _ ._._..._...._.._....._.._ .�._....
State work to be done and purpose of building (by floors).
• PROPOSE TO Fv,atuz i _ & . ,,
SINGLE HUNG, 28 COLONIAL SINGLE HUNG, 1 PICTURE WINDOW:.
and for no other purpose.
Remodeling XX �• Addition Repairs No. of Stories
New Building
To be constructed of Kind of foundation Roof Covering
Estimate Total cost of improvements $ 5400.00 Amount of Permit $. 2 9 t 2.5
Zone cubage required .Plan Cubage
Distance .to next nearest building Size of Building Lot
I hereby submit all the plans and specifications for-said building. All notices with reference to the building and its construction may
•
. SECURITY WINDOWS 5100 NW 72 AVE
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts hislobligations as an employer
of labor under the Florida \Vorkmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement,
anti has complied w ith the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him
in tkc work to be performed under this permit; and will post or cause to be posted f r inspection on the site of the work such public notice
or notices as are required by the Act. The undersigned agrees to employ only such abcontractors, of work to be performed under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed) 'ms ../&4 F..a
Mfaxirnum live load to be borne by each floor
STATE OF FLORIDA, 1
COUNTY OF DADE. j ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap
aY to me well known,
and who, being by me first duly sworn, upon oath deposes and says that he is the.
of the above described construction, that he has care fully read the foregoin • • : 'cation, and that he did sign lthe same, and that all facts
therein by him stated are true.
Permit No...;,;1./ Date 1 7 1 /17 ..._._._
Disapproved PDat
(Signed)
peared
Building Inspector
BUILDING INSPECTION DEPARTMENT
r , 9 t� ir y Public, State of Florida
My Bo u ifest..U1F.. . ...r.»......._.._.:._.....;._..
ONDfU rhR i NS . M ty 'i6 l9
Member $Wita
1
PLANNING BOARD
Chairman
Mlcrnber Member
Member ..... Member ...._ __.L _.....__
Council Approved Date Disapproved i Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A rc•in,pection ice of $1.00 will be charged when such re-inspection is made necessary by improper n for inspection or faulty
materials anti /or workmanship.
Square Ft. ,Affilr /
Signatur of owner and/or Condo President
/ 0
FEES: PERMIT (pD- RADON
756gi7
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date ? /o• 9 Job Address
/ 20/ /f/ 9(,
Tax Folio / /" 52 0 / <Y 3 .
Legal Description ,/ /L/ /3/4/ /) c /;
Owner /Lessee / Tenant Aj7gp / t - o�rt�
Owner's Address /20/ � /, 9 `s , Phone
Contracting Co. ,Se/Pcr
Qualifier /94/ / ° - /S/9 SS# �- Phone 9 I �d ��,
(/ /
State # ✓ 93aipal # Competency # Ins. Co.
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECH ROO PAVING FENCE SIGN
WORK DESCRIPTION AG `/ / /- ?o
if/ /ifa of /ti`s C.9 S4' e 7,
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating constructio ∎ d zoning. Furthermore, I authorize the above -named contractor to do the work stated
BALBIR SINGH KANDOLA
`'` o � ec. 9
Expu a. CC 520753
Bonded Thnj (Official Notary Omice
1 —(800) 723 - 0121
t , 0 3/9
Dae
APPROVED:
Zonin Buildin //)11,6
g g
si
Historically Designated: Yes
Master Permit #
Address -230/ 4 / 3:-: ' - ;
Estimated Cost (value)
: ature of Contractor o,
Electrical
wner- Builder
No
voyo
gWrit.
%GO �
BALBIR SINGH KANI)OI,AI
k a"tit ri i999
xptreMo. CC 520753
Bonded Thru (Official Notary em
I—(800)723-0121
at
ate
3O � o
C.C.F. / . NOTARY E OND
TOTAL DUE
Mechanical Plumbing Engineering
Job Address: /xf 9t' $ Contractor ° .._74l / Process No.
l2aol -168 W94
Base Sheet:
Fasteners:
APPENDIX 'E'
METRO -DADE UNIFORM BUILDING PERMIT
SECTION II
BUILT -UP APPLICATIONS AND
MODIFIED BITUMEN SYSTEMS
GENERAL:
Type of Roof System Assembly to be Applied:
Manufacturer of Roof System Assembly:
Product Control Approval Number:
System Number from Product Control Approval:
Complete the following for all Roof System Assemblies:
Built -Up Applications and Modified Bitumen Systems
Page -1
95
(Attach a copy of the Roof System Assembly Product Control Approval and the Manufacturer's System
Guide Specification. )
( Note: If a minimum roof system is to be applied, describe all
components within the system and list the manufacturer of
each component. DO NOT complete this section if system is
Product Control Approved. )
Ply Sheet(s):
. Cap Sheet:
Asphalt:
( Note: No insulation system is acceptable under the minimum
roof category. )
Job Address:
( Check . one of the following)
Recover Re -roof:
If a recover, is the existing Roof System Assembly
to be used as a bonding substrate ?:
If YES, has an ASTM E907 test been carried out
to confirm adhesion of the existing membrane to
the substrate ?:
(If 'yes', attach ASTM E907 test report. )
Proposed Fastener:
(Attach withdrawal resistance test report. )
Has the deck been examined for moisture ?: Y N
(Provide data confirming compliance with
Section 3401.9(c) . )
THE SYSTEM:
All Roof System Assemblies in the Product Approval have a variety of options. Briefly
describe the Roofing Components to be used in the Roof System Assembly and attach a copy of
the manufacturer's published specification:
Deck:
( Briefly describe )
Insulation:
(Type, size and method of attachment,
if applicable )
Base Sheet or Ply:
( Type and method of attachment )
Ply Sheet(s):
( Type and method of attachment )
Contractor
60 00
i
New Construction
Process No.
a, „
Built -Up Applications and Modified Bitumen Systems
Page -2
Job Address: Contractor Process No.
Top Ply:
(Type and method oj attachment )
Surfacing:
(Type, if applicable )
Flashing Materials:
( Type and method of attachment )
k/r,a0
Built -Up Applications and Modified Bitumen Systems
Pagc -3
Job Address:
Contractor
Built -Up Applications and Modified Bitumen Systems
Page -4
Process No.
inches
T
I _ inches
T
inches
FILL IN APPLICABLE ROOFING COMPONENTS WHICH MAKE
UP ROOF SYSTEM ASSEMBLY AND THICKNESS OF DECK AND
INSULATION LAYER(S). (Where Roofing Component not used in
Roof System Assembly, fill in with "N /A ".)
Sur facing:
(M t ty 4sr ►. i
•
op Ply '7.3 n
Bonding Mat �n(
Ply Sheet(s): a 61
Bonding Material:
Fastener: 1 f /4 *1 I T I
(VJbare sheet neck ono re
Base Sheet: r i
Bonding Material:
((lban sheer bonded )
Fastener:
� — Bonding Material:
(if,op emulation
layer bonded )
Fastener:
((/innlanan
neeh. orroched)
Insulation:
Bonding Material:
({/ 4wLnon bonded )
� Vapor R etarder.
(pgppleab
Primer.
(U•ppbcm)
DECK: JQ
Type: L Zfi
l Qt2Q
(((top rnnlonon toyer
meek onachrd)
Top Insulation Layer:
(/oppheable)
Gage or Thickness:
Density. if concrete deck:
Job Address:
Contractor
PERIMETER DETAIL #1: Parapet Wall Detail
Coping Cap
Gage:
Fastener
Spacing: _ o.c.
Clip Type:
Clip Gage:
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Parapet Walls.
Insert leaden indicating Roofing Component Hama,
dirnatsions, thicknesses, etc
Include fastener type and spacing used for wood-
blocking attachment.
Deck Type:
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Areas to be Flashed.
Insert leaders indicating Roofing Component names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
PERIMETER DETAIL #2: Flashing Detail
Built -Up Applications and Modified Bitumen Systems
Page -5
Process No.
Job Address:
Contractor
PERIMETER DETAIL #3: Gravel Stop or Drip Edge
Process No.
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Edge with Gravel
Stop or Drip Edge.
Insert leaden indicating Roofing Components names,
dimensions, thickneuea, etc.
Include fastener type and spacing used for wood-
Wading attachment
Gavel =Edge
Edge
Gage:
Fastener 1- , I 0
Spacing: ` o.c.
Clip Type:
Clip Gage:
Deck Type: 1/V)12
Sketch Roofing Components which make up Roof
System Assembly at Perimeter Edge with Guners.
Insert leaden indicating Roofing Component names,
dimensions, thicknesses, etc.
Include fastener type and spacing used for wood -
blocking attachment.
Gutter Type:
Gutter Gage:
Fastener
Spacing:
\f\fr
Deck Type:
PERIMETER DETAIL #4: Gutter Detail
Built -Up Applications and Modified Bitumen Systems
Page -6
Job Address: Contractor Process No.
Sketch Roofing Components which make up Roof
System Assembly at any 'other' Perimeter Condition
which may exisit
Insert leaders indicating Roofing Component names,
dimensions, thickrsses, etc.
Include fastener t and spacing used for wood -
blocking attach:. _
PERIMETER DETAIL #5: 'Other' Detail
Sketch Roofing Components which make up Roof
System Assembly at any 'other' Perimeter Condition
which may exisit
Insert leaders indicating Roofing Coruponent names,
dimensions, thickesses, etc
Include fastener type and spacing used for wood -
blocking attachment
PERIMETER DETAIL #6: 'Other' Detail
Built -Up Applications and Modified Bitumen Systems
Page -7
Job Address: Contractor Process No. 110►.
Insert Building and Parapet Heights.
(!f no Parapet exists. insert ?J/A")
Also insert applicable information pertaining
to the building below.
(See ASCE 7 -88 Fact Sheet Attached)
Exposure Category
Classification Category:
Al Hurricane Oceanline ?: Y N
Basic Wind Speed at
Building Location: l 10 mph
Building Condition based on
% of Openings:
GROUND LEVEL
feet
feet
BUILDING INFORMATION #1
Built -Up Applications and Modified Bitumen Systems
Page -8
Job Address: Contractor Process No.
Sketch Roof Plan indicating all dimensions, any slopes,
roof drains. crickets, or roof top equipment. Also insert
variable labeled "a" which indicates perimeter and comer
dimensions per Chapter 23 of the South Florida Building
Code.
( See ASCE 7 -88 Fact Sheet Attached )
BUILDING INFORMATION #2: Roof Plan with Perimeter and Corner Dimensions
Built -Up Applications and Modified Bitumen Systems
Page -9
Job Address: Contractor Process No. a
— FOR PLAN EXAMINER USE ONLY —
Roof System Assembly Product Control Approved: Y N
If NO, note any deficiencies:
Design Pressure Requirements:
Field: psf
Perimeter Areas: psf
Corner Areas: psf
Note any limitations:
Reviewed Details ?: Y N
Notes:
Built -Up Applications and Modified Bitumen Systems
Page -10
V
Job Address: Contractor Process No.
Reviewed Field Test Data ?:
Notes:
Additional Notes:
Built -Up Applications and Modified Bitumen Systems
Page -11
Y N
Plan Examiner
MEMO-DADE
MIN
EXPIRES: 11/10/97
APPROVED: J!3/14/96
()Jar.") a 13010 r Auso.A-74ec,
BUILDING CODE COMPLIANCE OFFICE
SUITE 1603
METRO DADE FLAGLER BUILDING
' 140 WEST FLAGLER STREET
1 tOJ) UCH' CONTROL NOTICE OF ACCEPTANCE' MIAMI, FLORIDA. 133130 -1563
GAF Materials Corporation (305) 375 -2901
FAX (305) 375 -2908
1361 Alps Road INTERNET: mdcc01@shadow.net
Wayne, NJ 07470
Your application for Product Approval of: PRODUCT CONTROL SECTION
(305) 375 -2902
GAF Conventional Built -Up Roof Systems FAX (305) 372 -6339
under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and
Types of Construction, and completely described in the plans, specifications and calculations as
submitted by:
I)yuatecli Engineering, Inc., Factory Mutual Research Corporation, and Underwriters
Laboratories, Inc.
has been recommended for acceptance by the Building Code Compliance Office to be used in Dade
County, Florida under the specific conditions set forth on pages 2 -98 and the standard conditions on page
99.
This approval shall not be valid after the expiration date stated below. The Building Code Compliance
Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's
plant for quality control testing.. If this product or material fails to perform in the approved manner, the
Building Code Compliance Office may revoke, modify, or suspend the use of such product or material
immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is
determined by the Building Code Compliance Office that this product or material fails to meet the
requirements of the Building Code Compliance Office that this product or Material fails to meet the
requirements of the South Florida Building Code.
The expense of such testing will be incyt`i by the manufacturer.
ACCEI'TANCE NO.: 95- 1003:3/ Revises No.: 94- 1014.01
1
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAIGLER BUILDING
aul Rodriguez
Product Control Division
Supervisor
iliaanLESABIERSHEELIEELAWaThEIALXAGES FOR SPECIFIC AND GENERAL
CONDITIONS
BUILDING CODE COMMITTEE
This application for Product-Approval has been reviewed by the Metropolitan Dade County Building
Code Compliance Office and approved by the Building Code Committee to be used in D County,
Florida under the conditions set forth above.
arles Danger, P.E.
Director
Building Code Compliance Dept.
Metropolitan Dade County •
GAF Materials Corporation
1361 Alps Road
Wayne, NJ 07470
CaleeotX: Membrane Roofing System
Su_b Catc_;ory1 Built -Up Roofing
Tvpe: Conventional
Sub- [yp Fiberglass
PRODUCr CONTROL NOTICE OF ACCEPTANCE
ROOTING SYSTEM APPROVAL
Product Control No.:
95- 1003.03
Product Control No.: 95- 1003.03
Approval Date: March 14. 1996
Expiration Date: Nov. 10. 1997
System Description,
GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years,
produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition,
GAF offers two ply modified systems to meet the demands for multi -ply SBS and APP modified
specifications.
GAF provides warranted systems over various insulated and non - insulated substrates, copies of which
can be obtained front GAF and can be found in the "GAFGLAS Built -Up Roofing Application and
Specifications" manual published annually.
GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and
Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida
Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material
Directory and the current Factory Mutual Approval Guide.
GAF Materials Corporation products are distributed through a wide network of roofing
dis!ributors throughout the South Florida area.
Contact:
William J. Woodring
Director of Technical Services
(201) 628-4134
2
wholesale
For more information on specific roof system constructions, contact the Technical Service Office,
located in Wayne, New Jersey, at 1- 800 - ROOF -411.
. 1115 /1 0
Frank Zuloaga ��
Plans Examiner, ‚1 'c ontrol Division
111 ll al n Iy12 €S:
Material
Basalt Wool
l'erlite
Polyisocyanurate
Composite Board
Wood Fiberboard
High Density Wood Fiberboard
Rockwool
Maximum Design Pressure
Wood -60 psf
Steel -75 psf
Concrete -192 psf
Lightweight Concrete -45 psf
Ceinentitiotfs Wood Fiber -45 psf
Poured Gypsum Concrete -45 psf
Maximum Fire Classification
Design Pressure
Magill • Classification
Wood Class 'A'
Steel Class 'A'
Concrete Class 'A'
Lightweight Concrete Class 'A'
Cementitious Wood Fiber Class 'A'
Poured Gypsum Concrete Class 'A'
Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck
types. Review system listings for design pressures and the Underwriters Laboratories Roofing
Materials Directory for Fire Classifications.
Frank Zuloaga
Plans Examiner,
3
Product Control No.: 95- 1003.03
ontrol Division
Test Product
Product Dimensions Specification Description
GAF Materials 5,'55 gallons ASTM D 41 Asphalt concrete primer used t
Corporation Asphalt promote adhesion of asphalt in
Concrete Primer roofing.
Granules
TRADE NAMES OF PRODUCTS MANUFACTURED OR
LABELED BY APPLICANT •
GAF Materials
Corporation Jetblak
All
Weather lylastic
Cement .
GAF Materials
Corporation Plastic
Cement .
GAF Materials 5 gallons
Corporation
WeatherCoat®
Emulsion
GAF Materials 1, 5 gallons
Corporation Fibered
Aluminum Coating
GAF Materials 1, 5 gallons ASTM D 3019
Corporation Jetblak ASTM D 3409
All
Weather Plastic
Cement
GAFGLAS #75® 3' x 108' ASTM D 4601
Base Sheet 75 lb. roll
GAFGLAS Ply 4 3' x 180' ASTM D 2178
40 lb. roll
ASTM D 2824 Fibered aluminum coating.
Frank Zuloaga
Plans Examine
4
Product Control No.: 95- 1003.03
- —
ontro
uilt -up
GAF Mineral Shield® 60 Ib. bags ASTM D 1863 Granules for surfacing of exposed
asphalt, cold process cement or il
emulsion. GAF Mineral Shield®
Granul shall be used for flashing
applications only.
1, 5 gallons ASTM D 3019 Refined asphalt blended with a mineral
ASTM D 3409 stabilizer and fibers. Permits adhesion
to wet and dry surfaces.
1, 5, 53 gallons ASTM D 4586 Trowel grade, asphalt plastic cement.
ASTM 1227 Surface coating for smooth surfaced
roofs.
Refined asphalt blended with a mineral
stabilizer and fibers. Permits adhesion
to wet and dry surfaces.
Asphalt impregnated and coated glass
mat base sheet.
GAFGLAS Ply 6® 3' x 180' ASTM D 2178 Type VI asphalt impregnated glass felt
45 Ib. roll with asphalt coating.
Type IV asphalt impregnated glass.felt
with asphalt coatin
'f }
Prodtie.I
GAFGLAS®
Mineral Surfaced
Cap Sheet
GAFGLAS® 3' x 36"
Stratavent® (Vent 691b. roll
Ply) for nailable decks
GAFGLAS® Flashing various
GAFGLAS® 3' x 36"
Stratavent® (Vent 60 Ib.• roll
Ply) Perforated
GAFTEMP®
Isotherm . R
GAFTEMP®
Composite
GAFTEMP®
Fiberboard
GAFTEMP®
Permalitee
GAFTEMP®
High Density
Fiberboard
GAFTITE® 1112
Standard
Roofing Fastener
GAFTITE® #I4
!Leavy Duty
Roofing Fastener
GAFTITE® Base
Sheet
Fastener and Plate
Dimensiosts
3' x 36'
76 Ib. roll
various
various
various
various
various
Test
S.Imikation
ASTM D 3909
ASTM D 4897
D 3672
PA 110
PA 114
PA 114
Product Control No.: 95- 1003.03
Product
Description
Asphalt coated, glass fiber mat cap sheet
surfaced with tnineral granules.
Fiber glass base sheet impregnated and
coated on both sides with asphalt.
Surfaced on the bottom side with
mineral granules embedded in asphaltic
coating.
Proprietary Asphalt coated glass fiber mat flashing
sheet available in three sizes.
ASTM D 4897 Fiber glass base sheet impregnated and
D 3672 coated on both sides with asphalt.
Surfaced on the bottom side with
mineral granules embedded in asphaltic
coating.
Polyisocyanurate foam insulation.
PA 110 Polyisocyanurate foam insulation with
high density fiberboard or Permalite
perlite insulation.
PA 110 Fiberboard insulation.
PA 110 Perlite insulation board.
PA 110 High density wood fiberboard
insulation.
Insulation fastener for steel and
plywood decks.
PA 114 Insulation fastener for steel, wood and
concrete decks.
Base sheet fastening assembly.
Frank Zuloaga
n ri'•_ 'r trot 1 ivi •
Plans Exanu e ,
5
NTB Fasteners PA 114
Polypropylene Plates 3" and 3 Vi" PA 1 14
Ruberoid® 20 1.5 sq. roll ASTM D 5147
Ruberoid® Mop 1 sq. roll
Granule 103 lbs.
ASTM D 5147
Frank Zuloaga
Plans Examiner,
6
Product Control No.:
Test Product
Product Dimensions Specification Description
Galvalume Plates 3" and 3 %2" PA 114 Round galvalume stress plates
Fastener for use in gypsum, tectum and
lightweight insulating concrete decks.
Round polypropylene stress plates.
SBS modified asphalt base sheet
reinforce with a glass fiber mat.
95- 1003.03
Non -woven polyester mat coated with
polymer modified asphalt and surfaced
with mineral granules.
Vent Stacks (metal PA 100(A) One way valve vent used to relieve
and plastic) ASTM D 1929 built -up pressure within the roof system.
' ASTM D 635 GAF Vent Stacks are available in metal
or plastic.
ontrol Division
Product
I'yrox
ACFoam 1
ACFoam 11
Celcore
Test Product
Dimensions Specification Description
various PA 110
various PA 110
various PA 110
PA 110
I {y -Therm Nail -line various PA 110
1-ly -Therm SP various PA 110
Fly-Therm AP various PA 110
lly -Therm Stable It various I'A 110
fly -Therm White various PA 110
Line
VaporBar GB
Anchorbond PA 114
Fastener
I)ekfast Fasteners
1114
TRADE NAMES OF PRODUCT'S MANUFACTURED BY OTHERS
PA 114
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Cellular insulating concrete
system
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation.
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
36" x 108' ASTM D 4601 G2 fiberglas base sheet
Insulation fastening
assembly
Insulation fastener for steel
and concrete decks
Product Control No.: 95- 1003.03
Manufacturer
Apache Products Co.
(with current PCA)
Atlas Energy
Products
(with current PCA)
Atlas Energy
Products
(with current PCA)
Celcore, Inc.
(with current PCA)
Celotex Corp.
(with current PCA)
Celotex Corp.'
, (with current PCA)
Celotex Corp.
(with current
Celotex Corp.
(with current 1
CA)
CA)
Celotex Corp.
(with current PCA)
Celotex Corp.
(with current PCA)
Celotex Corp.
(with current PCA)
Construction
Fasteners Inc.
Frank Zuloaga
Plans Examine ontrol a i
7
Rio'
• &QdW1
Dimensions
Dekfast ilex Plate 2 7/8" x
3 1/4"
Dekfast Lock Plate 3" x 3 1/4"
Dekfast Fasteners
#15
Dekfast Fasteners
11 12
TPR
Elastizell
FM -30, FM-45,
FM -60, FM -90
Fasteners
Nail -Tite Type 'A'
Nail -rite Type 'R'
ISO 95+ Composite
Test Product
Specification Description
PA 114 Galvalume hex stress plate. Construction
Fasteners Inc.
(with current PCA)
PA 114
PA 114
PA 114
PA 114
PA 110
PA 114
PA 114
PA 114
PA 110
Polypropylene locking
plate.
Insulation fasteners for
concrete decks
Insulation fastener for steel
and wood decks.
Aluminum fastener for
lightweight, gypsum and
tectum decks
Cellular insulating concrete
system
Base ply fastening systems
for lightweight concrete
decks
Galvanized steel base ply
fastener for lightweight
concrete decks
Galvanized steel base ply
fastener for lightweight
concrete decks
Polyisocyanurate / perlite
ridged insulation
Frank Zuloaga
Plans Examiner,
8
Product Control No.: 95- 1003.03
Manufacturer
Construction
Fasteners Inc.
(with current PCA)
Construction
Fasteners Inc.
(with current PCA)
Construction
Fasteners Inc.
(with current PCA)
Creative
Construction
Components
(with current PCA)
Elastizell Corp.
(with current PCA)
ES Products
(with curren
ES Products
(with curren
Inc.
PCA)
Cnc.
PCA)
ES Products, Inc. _
(with current PCA)
Firestone
(with current PCA)
ontrol Divisio
•
Pjoduct
Asphalt
Asphalt Primer
El'S
Perlite Insulation
Polyethylene
Rcd Rosin
Test Product
Dimensions Specification Description
various
Iligh Density Wood various
Fiberboard
Oriented Strand various
Board
Pelite /Urethane various
Composite'
Rooting Nails
Tin Caps
Type X Gypsum various
Type X Gypsum various
al MB aluminum
roof coating
Dcns -Deck various
various PA 110
4 mil min.
various
Minimum # PAI 14
12
Min. 32 ga. x
1 5 4 1
Product Control No.: 95- 1003.03
Manufacturer
ASTM D 312 Type 111 or IV Ilot asphalt generic
bitumen adhesive
Asphalt Primer
PA 110 Extruded polystyrene
insulation
PA 110 Wood fiber insulation
board
PA 110 Oriented strand board
ASTM D 41
PA 110
generic
generic
generic
generic
Perlite / urethane composite generic
board insulation
Perlite insulation board generic
Vapor barrier / Air barrier generic
Rosin paper for barrier
layer on wood decks
generic
Corrosion resistant annular generic
ring shank nails
Corrosion resistant circular generic
discs.
Fire resistant rated gypsum generic
Fire resistant rated gypsum generic
PA 121 Aluminum roof coating Grundy Industries
(with current PCA)
PA 110 Gypsurn insulation board. Georgia Pac frc
Frank Zuloaga
Plans Examiner,
9
ontrol Drvisi
•
Product
1112 Roofgrip
I/14 Roofgrip
Gripdek Fastener
I- lexcel Fastener
1-lextra PA 114
Standard Plastic
Plate
ISO 95 +
E'NRG'Y -2
1SORoc
Con -Cite
N.T.B. Magnum
Test Product
Dimensions Specification Description
3" round PA 114
various PA 110
various PA 110
various PA 110
PA 114
PA 114
PA 114 insulation fastener for steel ITW Buildex
• or wood decks • (with current PCA)
PA 114 Insulation fastener steel, ITW Buildex
• wood or concrete decks (with current PCA)
PA 114
PA 114
Insulation fastener
Insulation fastener
Insulation fastener and
metal or plastic plate
Polyolefin plastic plate
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam /
rockwool composite
insulation
Concrete deck insulation
fastener
Glass reinforced nylon
fastener for use in gypsum
and cementitious wood
fiber decks.
Frank Zuloaga
Plans Examiner,
10
Product Control No.: 95- 1003.03
Manufacturer
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
ITW Buildex
(with current PCA)
International
Permalite
(with current PCA)
NRG Barriers, Inc.
(with current PCA)
NRG Barriers, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
• L
ontrol Divistot
riosli!c.t
Dimensions
N.T.B. Spin 2" round
Weld Plate
N.T.B. Plastic Plate 3" round
N.T.B. Plate
Olympic Standard 3" round
Olympic Fastener
#I4
Olympic
Polypropylene
Olympic Fastener
#12
Olympic Fastener
Test
Specification
PA 114
PA 114
PA 114
PA 114
PA 114
3.25" round PA 114
PA 114
PA 114
Product
Description
2" round amorphorus nylon
locking plate for use with
N.T.B. fasteners with 1"
head
3" round polypropylene
stress plate for use with
N.T.B. fasteners
3" round galvalume AZ55
plate for use with N.T.B.
fasteners
3" round galvalume
AZ55 steel plate
Insulation fastener
Polypropylene
plastic plate
Insulation fastener
Insulation fastener
Frank Zuloaga
Plans Examiner,
Il
Product Control No.: 95- 1003.03
—
Manufacturer
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Olympic
Manufacturing
Group, Inc.
(with current PCA)
ontrol Division
P thi 1
Olympic CR Base
Felt Fastener and
Base Sheet Disc
Test Product
Dimensions Specification Description
PA 114
GlasFast Fastener PA 114
GlasFast/Striker PA 114
Paroc Base Board various PA 110
•
I'aroc Cap Board various PA 110
Multi -Max various PA 110
Multi -Max FA 'various PA 110
UltraGard various PA 110
lnsul -Fixx Fastener
Insul -Fixx P
Rawl Drive
PA 114
3" round PA 114
PA 114
Insulation fastener
Assembly for Base Sheet
fastening only
Insulation fastener
assembly with recessed
plastic plate
Insulation fastener
assembly and metal plate
for use over concrete decks
Rockwool insulation
Rockwool insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Polyisocyanurate foam
insulation
Insulation fastener for steel
and wood decks
3" round polyethylene
stress plate
Insulation fastener and steel
and plastic stress plate for
concrete deck
Frank Zuloaga
Plans Examiner,
12
Product Control No.: 95-1003.03
Manu facturer
Olympic
Manufacturing
Group, Inc.
(with current PCA)
Owens- Corning
Fiberglas Corp.
(with current PCA)
Owens - Corning
Fiberglas Corp.
(with current PCA)
Partek, Inc.
(with current PCA)
Partek, Inc.
(with current PCA)
Rmax, Inc.
(with curren
PCA)
Rmax, Inc.
(with current PCA)
Schul ler
International Inc.
(with current PCA)
SFS /Stadler
(with current PCA)
SFS /Stadler
(with current PCA)
The Rawlplug
Company Inc.
(with current PCA)
ontrol Divis
Produci
Rawl Fasteners
�t 12
Rawl Fasteners
11 14
Rawl 2" Plate 2" round
Rawl 3" Plate 3" round
Rawl Spike
Rawlite
Rawlite 3" Plate 3" round
202 HS
Super Prep II
Tru -Fast DL
Test
Dimensions Specification
PA 114 Insulation fastener for steel The Rawlplug
and wood decks Company Inc.
(with current PCA)
PA 114
PA 114 2" round galvalume AZ55 The Rawlplug
membrane plate Company Inc,
(with current 'PCA) '
PA 114 3" round galvalume AZ55 The Rawlplug
steel plate Company Inc.
(with current PCA)
PA 114 Insulation fastener and steel The Rawlplug
and plastic stress plate for Company [no
concrete deck (with current'. PCA)
PA 114
PA 114
PA 121
PA 121
—
Product
Description Manufacturer
Insulation fastener for use
in steel, wood or concrete
Insulation fastener for
cementitious and gypsum
decks
3" round galvalume AZ55
steel plate for use with
Rawlite fasteners
Roof coating
Roof coating
Product Control No.: 95- 1003.03
The Rawlplug
Company Inc.
(with current PCA)
The Rawlplug
Company Inc.
(with current PCA)
The Rawlplug
Company Inc.
(with current PCA)
Thermo - Materials,
Inc.
(with current PCA)
Thermo- Materials, _
Inc.
(with current PCA)
PA 114 Insulation fastener for steel, Tru -Fast
or wood (with current PCA)
Frank Zuloaga
Plans Examiner,
13
ontrol Division
Product Dimensions
Tru -Fast Plastic 3.04" round PA 114
Plate
Tru -Fast MP -3 3.23" round PA 114
Tru -Fast 1-ID PA 114
Tru -Fast Ultra PA 114
Tru -Fast TL
Tru -Fast .DP
Tru -Fast TP
Tru -Fast CF
Fasteners •
Insulcel
Structodeck
Test
. ap eifcatiort
PA 114
PA 114
PA 114
PA 114
PA 110
various PA 110
Product
Description
3.04" round polyethylene
plastic plate
3.23" round galvalume
• AZ50 steel plate
Insulation fastener for use
in wood, steel or concrete
decks
Stainless Steel fastener for
use in steel, wood and
concrete decks
Glass reinforced nylon
fastener for use in tectum or
gypsum decks
Insulation fastener for use
in steel or wood decks
Insulation fastener for use
in steel or wood decks
Insulation fastener for
concrete decks
Cellular insulating concrete
system
High density wood fiber
Frank Zuloaga
Plans Examiner' ••"fi
14
Product Control No.: 95- 1003.03
Manufacturer
Tru -Fast
(with current PCA)
Tru -Fast
(with current PCA)
Tru -Fast
(with curren PCA)
Tru -Fast
(with current PCA)
Tru -Fast
(with current PCA)
Tru -Fast
(with current PCA)
Tru -Fast
(with current PCA)
Tru -Fast
(with current PCA)
W.R. Grace .
(with current PCA)
Wood Fiber
Industries
(with current PCA)
is
ontrol Division
•
:Lot Agency /Identifier
Factory Mutual Research
Corporation
Underwriters
Laboratories, Inc.
Y
Dynatech Engineering,
Inc.
Name
FMRC 1994
J.I. #OT4A LAM
J.I. # I V8A4.AM
J.1. #IRIA6.AM
J.I. #0T2Q4.AM
J.I. #0Q6A6.AM
J.I. #3X3A2.AM
J.1. #0Y9Q5.AM '
R1306, 87NK1 1819
3600.02.95
4482.02.95
Test Reports
Report
Current Insulation
Fastening Requirements
Uplift Approval
Uplift Approval
Uplift Approval
Uplift Approval
Uplift Approval
Uplift Approval
Uplift Approval
Class A Fire
Classification
Wind Uplift, Small
Scale
Wind Uplift
Frank Zuloaga
Plans Examiner
15
Product Control No.: 95- 1003.03
Date
01.01.94
08.26.92
06.28.93
11.15.91
10.17.91
07.16.91
08.02.94
07.29.94
01.01.93
02.02.95
02.02.95
Deck Type 1:
Deck Description:
System Type A(1):
Base Sheet:
Ply Sheet:
Cap Sheet:
Surfacing:
Maximum Design
Pressure:
Maximum Fire
Classification:
Maximum Slope:
Specification No.:
Wood, Non - insulated
19 4 2 " or greater plywood or wood plank decks
Base sheet mechanically fastened.
MI General and System Limitations shall apply.
Product Control No.
95- 1003.03
GAFGLAS® 475, GAFGLAS® PLY 6 ®, GAFGLAS® STRATAVENT® or
RUBEROID® 20 applied to the deck with approved annular ring shank nails and
minimum 1 5 4" tin caps at a fastener spacing of 12" o.c. at the lap, 18" o.c. in two
rows staggered along the center line of the sheet in the field.
Two or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® ply sheet
adhered in a full mopping of approved asphalt applied within the EVT range and at
a rate of 20 -40 lbs. /sq..
(Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range and at a rate of 20 -40
IbsJsq..
(Required if no cap sheet is used) Install one of the following:
1. Grundy AL MB aluminum Roof Coating with an application rate of
1.5 gal /sq.; or GAF WEATHER COAT® Emulsion with an
application rate of 3 gal./sq.; or GAF Fibered Aluminum Coating
with an application rate of 1.5 gal. /sq..
2. Asphalt flood coat at an application rate of 60 lbsJsq. ± 20 %; plus
gravel or slag with an application rate of 400 lbs. /sq. & 300 lbsisq.,
respectively.
-45 psf.
'A'. See General Limitation #2.
3 ":12 "; See General Limitation #3.
N- B -3 -C, N- B -3 -G NFB -4 -M, N- B- 4M /P6, N- B -4 -C, N- B- 4 -C /P6, N- B -4 -G,
N- B- 4 -G/PG, N- B -5 -C, N- B- 5 -C/P6, N- 13-S -C, N- B- 5 -C/P6, N- B -5 -G,
N- 13- 5 -G /P6, N- B -5 -M, N- B- S -M/P6
Frank Zuloaga
Plans Examiner,
26
• . uct Control Division
a. Deck Type: " /, Plywood.
Product Control No.: 95- 1003.03
Wood Deck
System Limitations:
1. A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt
seepage and bonding of base sheet to plank and deck. Red rosin sheet may also
be installed on plywood decks as an option.
2. A slip sheet is required with GAFGLAS® PLY 4 and PLY 6® when used as a
mechanically fastened base or anchor sheet.
3. Pre - assembled cap nails may only be used for termination of fully bonded
surfaces such as mechanical termination at wood blocking, head and side laps,
and base flashing terminations. Cap nails shall not be used for the mechanical
attachment of a base sheet. Tin caps are required by the South Florida Building
Code. Pre - assembled 'Cap Nail' shall not be used for base sheet attachment.
4.* The following assembly is approved to a maximum design pressure of -52 psf.
No substitutions shall be made:
b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet,
GAFGLAS® Ply 60, or STRATAVENT® (Vent Ply) for nailable
decks, or RUBEROID® 20 base sheet.
Fastening: Nailed 9" o.c. at the lap and in two tows staggered 18" in the
field, nailed with 11 ga. annular ring shank nails and 1 s /," tin caps.
c. Insulation:
Base Layer: (Optional) Min. 1.2" E'NRG'Y 2, 2 Plus, AC Foam 1, 11 or
GAFTEMP Isotherm R adhered to the Anchor Sheet in a full mopping of
approved asphalt applied within the EVT range at a rate of 20 -40
lbs. /sq..
Top Layer: Min. '' /s" approved wood fiberboard adhered to the base
insulation layer in a full mopping of approved asphalt applied within the
EVT range at a rate of 20 -40 lbsisq..
d. Base Sheet: (Optional) Install one ply of GAFGLAS® 475 directly over
the top layer of insulation. Adhere with any approved mopping asphalt
applied within the EVT range and at a rate of 20 -40 lbs. /sq..
e. Ply Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or
GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved
asphalt applied within the EVT range an
Frank Zuloaga
Plans Examine
28
•
g.
a. Deck Type: ' Plywood.
20 lb/sq.; or Grundy AL M
an application rate of 1.5
Frank Zuloaga
Plans Examine
29
1. tr0 • •
Product Control No.: 95- 1003.03
f. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet
adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20 -40 lbs. /sq..
Surfacing: (Optional) Install one of the following:
1. GAF Special Roofing Bitumen with an application rate of
20 lb. /sq.; or Grundy AL MB aluminum Roof Coating with
an application rate of 1.5 galisq.; or GAF WEATHER
COAT® Emulsion with an application rate of 3 gal/sq.; or
GAF Fibered Aluminum Coating with an application rate of
1.5 gal. /sq..
2. Asphalt flood coat at an application rate of 60 •Ibsisq. f
20 %; plus gravel or slag with an application rate of 400
lbs. /sq. & 300 lbsisq., respectively.
5. The following assembly is approved to a maximum design pressure of -52 psf.
No substitutions shall be made:
b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet,
GAFGLAS® Ply 60, or STRATAVENT® (Vent Ply) for Nailable
decks, or RUBEROID® 20 base sheet.
Fastening: 9" o.c. at the lap and in two rows staggered 18" in the field
with GAFTITE® insulation screws and steel stress plates.
c. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 directly over
the top layer of insulation. Adhere with any approved mopping asphalt
applied within the EVT range and at a rate of 20 -40 Ibs.sq..
d. Ply Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or
GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq..
e. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet
adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20 -40 lbs. /sq..
f. Surfacing: (Required if no cap sheet is used) 'Install one of the
following:
I. GAF Special Roofing Bitumen with an application rate of
.1 •.:.. .. .... with
or G WEATHE
Product Control No.: 95- 1003.03
COAT® Emulsion with an application rate of 3 gal. /sq.; or
GAF Fibered Aluminum Coating with an application rate of
1.5 gal. /sq..
2. Asphalt flood coat at an application rate of 60 lbs. /sq. ±
20 %; plus gravel or slag with an .application rate of 400
lbs. /sq. & 300 lbs. /sq., respectively.
*Note: The maximum designed pressure limitation listed shall be applicable to
all roof pressure zones (i.e. field, perimeters, corners). No rational
analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners, and
corners).
Frank Zuloaga
Plans Examine `control Divisio
30
General Limitations:
Application.
Frank Zuloaga
Plans Examine
97
Product Control No.
95- 1003.03
1. All asphalt shall comply with ASTM D 312 type III or type IV requirements. All
proposed asphalt producers must be approved by the applicant.
2. Fire ratings are determined by a combination of slope, deck type and assembly.
Refer to current Underwriters Roofing Materials Directory or other fire testing data
listed in the testing file. Fire ratings shall be in strict compliance with Sections
3401.5 and 3401.6 of the South Florida Building Code.
3. Maximum slope range shall vary for each system; consult current Underwriters
Laboratories Roofing Materials Directory and manufacturer's specifications for
compliance with design criteria for each project.
4. An overlay /recovery board insulation panel is required on all applications over
closed cell foam insulations when the base sheet is fully mopped. If no recovery
board is used the base sheet may be applied using spot mopping with approved
asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one
at each sidelap and one down the center of the sheet allowing a continuous area of
ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed
every 12' in each ribbon to allow cross ventilation. Asphalt application of either
system shall be at a minimum rate of 12 lbs. /sq.. Note maximum design pressure
restrictions on spot attached systems.
5. All work shall be performed by a contractor licensed to do roofing work in Dade
County. Contractor shall be familiar with the details and specifications published by
the manufacturer. •
6. In re- roofing applications, moisture content in an existing roof must be in
'compliance with Section 3401.10(m), (n) of the South Florida Building Code.
7. Prior to application, all existing roof surfaces used as a bonding substrate shall be
tested for uplift resistance in compliance with Dade County Protocol PA 124 to the
calculated design pressure of the roof deck.
8. If required, any Factory Mutual Approved vapor barrier in conjunction with
proprietary or approved adhesives may be used prior to the application of the
insulation layer.
9. Perimeter and corner areas shall have an increase in fastener density for both
insulation and base sheet in compliance with Dade County Protocol PA 117 of the
South Florida Building Code.
10. All attachment and sizing of perimeter nailers and metal profile designs shall
conform with Dade County Protocol PA 1 1 1 of the South Florida Building Code.
I I. Flaslrings shall be installed according to the manufacturers standard details, and may
be applied in cold application adhesive, approved asphalt or may be applied in
conjunction with an approved torch applied modified bitumen membrane. Specific
details, approved by the manufacturer, shall be sub ?C
metro r • _
12. Roll good materials shall be stored on end and on a clean, flat and dry surface.
13. Consult current Underwriters Laboratories Directory for the appropriate coating for
each roofing assembly to obtain the required fire rating. The assembly shall be
installed in strict compliance with Chapter 3401.5 and 340.1.6 of the South Florida
Building Code for maximum fire classification.
14. Asphalt moppings shall be with applied with asphalt approved by the applicant and
shall be approved in compliance with equiviscous temperature (EVT) methods of
asphalt deterniination. Asphalt containers or bulk tickets shall indicate an EVT,
finished blowing temperature (FBT) and flash point. Asphalt types and temperature
ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida
Building Code.
15. Insulation may be installed in multiple layers. . The first layer shall be attached in
compliance with Product Control Approval guidelines. All other layer's shall be
adhered in a full mopping of approved asphalt applied within the EVT range and at a
rate of 20 -40 lbs./sq., or mechanically attached using the fastening pattern) of the top
layer. Refer to manufacturer's literature and/or the NRCA Roofing and
Waterproofing Manual for correct application procedures of insulation panels in
approved asphalt or adhesive.
16. Pre - assembled cap nails may only be used for termination of fully bonded surfaces
such as mechanical termination at wood blocking, head and side laps, and base
flashing terminations. Cap nails shall not be used for the mechanical attachment of a
base sheet. Tin caps are required by the South Florida Building Code.
17. The submission of system specifications and details shall accompany the Section 1I
Building Code Permit. This information is available in the publications listed in the
'System Description' of this Product Control Approval. The submission of these
documents, as well as the proper application and installation of all materials shall be
the sole responsibility of the contractor.
18. All standard panel sizes are acceptable for mechanical attachment. When
approved asphalt, panel size shall be 4' x 4' maximum.
19. Fastener spacing for insulation attachment is based on a minimum withdrawal
resistance value of 275 Ibf. as tested in compliance with PA 105. If the fastener
value, as field tested, are below 275 Ibf. insulation attachment shall not be
acceptable.
Frank Zuloaga
Plans Examiner,
98
•■■Allio
A 4 , 0
IIIIIIN.- ..1111
ontrol I iv
Product Control No.: 95- 100103
applied in
GAF Materials Corporation
1361 Alps Road
Wayne, NJ 07470
5.
Product Control No.: 95- 1003.03
ACCEPTANCE NO.: 95- 1003.03
APPROVED : March 14. 199G
EXPIRES : -Nov. 10. 1997 I
IQTICE OF ACCEPTANCE STANDARD CONDITIONS
1. Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and
the original subtnitted documentation, including test supporting data, engineering documents, are no older
than eight (8) years.
2. Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and
the following statement: "Dade County Product Control Approved ", or as specifically stated in the specific
conditions of this Acceptance.
3. Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of
this product and the product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved;
c) If the Acceptance holder has not complied with all the requirements of this acceptance,
► including the correct installation of the product;
d) The engineer who originally prepared, signed and sealed the required documentation
initially submitted , is no longer practicing the engineering profession.
4. Any revision or change in the materials, use, and/or manufacture of the product or process shall
automatically be cause for termination of this Acceptance, unless prior written approval has been requested
(through the filing of a revision application with appropriate fee) and granted by this office.
Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any
other purposes.
6. The Notice of Acceptance nuniber preceded by the words Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
7. A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be
provided to the user by the rnanufacturer or its distributors and shall be available for inspection at the job
site at all times. The copies need not be resealed by the engineer.
8. Failure to comply with any section of this Acceptance shall be cause for termination and removal of
Acceptance.
9. This Acceptance contains pages I through 99 .
END OF THIS ACCEPTANCE
Frank Zuloaga
Plans Exanriner,Ztro 1 • .
99
�„ .. 214
ROOF COVERING MATERIALS (TEVT)
ROOFING SYSTEMS. (TGFU)—Continued
Surfacing: "Gacoflex UA -85 ", applied at 1 gaV sq. (12 dry mils).
39. Deck: NC Incline: 1 -1/2
Foam: "Polyfoam 251" or "Polyfoam 303 ", 1 in. min.
Base Coat One or two applications "Gacoflex UB- 6499 ", applied at 1.2 gaVsq. per applica-
tion (14 -28 dry mils).
Surfacing: "Gacoflex A- 55000 ", applied at 1 -1/2 gaV sq. (14 dry mils).
40. Deck: NC Incline: 1/4
Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min.
Top Coat Two Applications "Ure -Cap 88" Series coating (various colors) applied at 1.3/8 gaV
sq /application or 3 applications applied 1 -1/4 gaVsq/application.
Top Coat (Optional): One application of "Gacoflex UA -65" Series (various colors) applied at 1
gal /sq or "Gacoflex UA-60" applied at 1 -1/4 gaVsq (12 dry mils).
41. Deck: NC Incline: 1/4
Foam: "Poly -Iso" or "Poly -Iso Special" with "Polyfoam 251" or " Polyfoam 303", 1 in. min.
Base Coat One or two applications "Gacoflex UB -64 ", 1 gal /sq /application (12 -24 dry mils).
Surfacing: "Gacoflex UA -65" Series 1 gal /sq or "Gacoflex UA -60" applied at 1 -1/4 gal /sq (12
dry mils).
42. Deck: NC Incline: 1/4
Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min.
Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or 3
applications applied 1-1/4 gal /sq /application (16-32 dry mils).
Surfacing: "Gacoflex UA-65" Series (various colors) applied 1 gal /sq (12 dry mils).
43. Deck: NC Incline: 1/2
Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or " Polyfoam 303 ", 1 in. min.
Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or 3
applications applied 1-1/4 gal /sq /application (16-32 dry mils).
Surfacing: "Gacoflex UA -60" Series (various colors) applied 1 gal /sq (15 dry mils).
44. Deck: NC Incline: 2
Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min.
Base Coat "GacoSil S- 1000" applied at 1 gaVsq (10 dry mils).
Surfacing: "Gacoflex S- 1000" applied at 1 gal /sq (10 dry mils).
45. Deck: NC Incline: 1
Foam: " Polyfoam 251" or " Polyfoam 303 ", any thickness.
Surfacing: "Gacoflex Ure- Shield 7007", 40 dry mils.
GAF MATERIALS CORP, WAYNE NJ 07470 R1306 (N)
" RUBEROID 20" or "RUBEROID Mod Base 30" may be utilized as an alternate to Type G2 base
sheets in any of the following Classifications.
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet (" GAFGLAS #75 Base Sheet") is a suitable alternate for
Type G1 asphalt glass fiber ply sheet (" GAFGLAS Ply 4" or "GAFGLAS Ply 6") in the Class A, B or C
roof systems indicated below.
The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAFGLAS Stre-
tavent (Vent -Ply) perforated" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ". Perforated to be
mopped and nailable to be mechanically' attached granule side down.
As an option Type G2 asphalt glass mat base sheet (' GAFGLAS #75 Base Sheet" or " GAFGLAS
Stratavent (Vent -Ply) for nailable decks ") may be subsituted for G1 asphalt glass fiber ply sheet
( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") as the nailed base ply in the following systems.
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened.
Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened.
" GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C sys-
tems listed below.
When "perlite" is referenced, this includes " GAFTEMP Perlite" or any other UL Classified perlite
insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems list-
ed.
Structural cement fiber building units are considered suitable to be included as a deck in the fol-
lowing Class A, B or C systems listed over C -15/32 or NC.
The use of gypsum board under any of the following Class A, B or C systems does not adversely
effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over
C -15/32 decks.
The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin Pa
per (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the fol-
lowing Class A, B or C systems.
"GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP Composite A" may be
substituted for any isocyanurate insulation in any of the following Classifications.
Class A. B and C.
Hot roofing asphalt, for use with organic pnd glass felts or modified bitumen membranes.
Class A
1. Deck: C -15/32 . Incline: 3
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Ply Sheet Three or more layers Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", hot
mopped.
Surfacing: Gravel.
2. Deck: C -15/32 incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Ply Sheet Three or more layers Type G1 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ".
ROOFING SYSTEMS (TGFU)— Continued
Deck: NC Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber. glass fiber, isocyanurate, ure-
thane, perlite/isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, 2 in. max.
ply Sheet Two or more layers Type 61 "GAFGLAS Ply 4" or "GAFGLAS Ply 6".
Cap Sheet One layer Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ".
Deck: NC Incline: 1/2
Insulation One or two layers "Isotherm R ", 4 in. max, hot mopped.
Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system.
fly Deck: C -15/32 Incline: 1
Slip Sheet (Optional): Red rosin paper, nailed to deck.
Base Sheet One layer of Type G2 " GAFGLAS #75 Base Sheet" (may be nailed).
Ply Sheet One or more layers of Type G1 " GAFGLAS Ply 4" or GAFGLAS Ply 6 ".
Cep Sheet One layer of Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ".
8 , Deck NC Incline: 3
Base Sheet One layer of Type G2 " GAFGLAS #75 Base Sheet ".
Ply Sheet One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply 6 ".
Cap Sheet One layer of Type G -3 " GAFGLAS Mineral Surfaced Cap Sheet ".
7. Deck: C -15/32 Incline: 2
Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate
composite, perlite /urethane composite, phenolic, 1.0 in. min (off -set from plywood joints 6 in.).
,Base Sheet One or more layers of Type 61, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch
Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule).
Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped.
Deck: C -15/32 Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Base Sheet Two.or more layers of Type G2 or G3.
Ply Sheet (Optional): One or more layers of Type G1.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch
Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule).
Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped.
Class B
1. Deck: C -15/32 Incline: 3.1/2
Insulation (Optional)- One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure-
thane, perlite/isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic. any thickness.
Ply Sheet Two or more layers of Type 61 " GAFGLAS Ply 4" or " GAFGLAS Ply 6"
Cep Sheet Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped.
2. Deck: C -15/32 Incline: 3 -1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate. ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Base Sheet Two or more layers of Type 61, G2 or G3.
Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch
Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule).
Cap Sheet " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped.
Class C
1. Deck C -15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber. isocyanurate, ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood finer /isocyanurate
composite, phenolic, any thickness.
Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ".
Surfacing: "Special Roofing Bitumen" 20 Ibs /sq.
COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR
Class A
I. Deck: C -15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or " GAFGLAS Ply 6 ", hot
mopped with coal tar bitumen.
Surfacing: Gravel.
COMBINATION 140T AND COLD SYSTEMS
Class A
I. Deck: NC Incline: 2
Insulation (Optional): One or mere layers perlite, wood fiber or glass fiber, 2 in. max.
Ply Sheet Three or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ".
Surfacing: Grundy Industries "al MB Aluminum Roof Coating" at 1 -1/2 gal /so.
2. Deck: NC Incline: 1
Insulation (Optional) One or more layers perlite, wood fiber. glass fiber, isocyanurate. ure-
thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate
composite, phenolic, any thickness.
Ply Sheet Three or more layers of Type G1 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ".
Surfacing: "Weather Coat.Emulsion" at 3 gal /sq.
3 . Deck NC • Incline: 1/2
Insulation: One or two layers "Isotherm R", 4 in., hot mopped.
Ply Sheet Any UL Classified gravel surfaced Class A asphalt glass fiber mat system.
Class B
1, Deleted.
2 . Deck C -15/32 Incline: 2
fiber nlass fiber. isocyanurate, ure-
8.
ROOF COVERING MATERIALS (TEVT) 215