Loading...
1147 NE 97 St (14)APPLICATION FOR CERTIFICATE OF RE- OCCUPANCY hereby apply for a certificate to re- occupy the single family residence known as: (address) Legal description: Lot: I hereby certify that I understand that the zoning of the property is for single - family residential use and that it is unlawful for more than one family to reside therein. I also understand that any Certificate of Re-Occupancy that may be issued by Miami Shores Village, Florida, certifies only that the referenced property is being used for single - family purposes and that such Certificate does not constitute any representation, warranty or certification as to the condition of the dwelling or other structures on such property. Applicant: Print Name: Inspection: By Continents: t • C I21 C f i Date: b 6 ,Block: ,PB&PG: Contact Name: Telephone: Buyer._ Seller._ Realtor._ Company Name: Miami Shores, Florida. For the purposes of conducting the inspection required by Section 902 of the Miami Shores Development and Zoning Code, contact: Application Fee (350) Paid: Cash: Number. 1772 . Approved: ►'Denied:_Date: fl'/ CERTIFICATE OF RE- OCCUPANCY On behalf of Miami Shores Village, Florida, the undersigned certifies that the property described in the application has been inspected for the purposes of re- occupancy pursuant to Sections 901 and 902 of the Miami Shores Land Development and Zoning Code and that such property may be re- occupied by the applicant for single - family residential purposes. Date of Certification: THIS CERI'Ii4ICATE VERIFIES THAT THE REFERENCED PROPERTY HAS BEEN INSPEt; I'ED BY MIAMI SHORES VILLAGE AND HAS BEEN DETERMINED TO PRESENTLY COMPLY WITH THE SCHEDULE OF REGULATIONS OF THE MIAMI SHORES LAND AND DEVELOPMENT CODE PERTAINING SOLELY TO THE REQUIREMENT THAT EACH ONE - FAMILY DWELLING IS USED AND INTENDED TO BE USED FOR A ONE - FAMILY DWELLING PURPOSE ONLY; HOWEVER, THIS CERTIFICATE DOES NOT CONSTITUTE ANY REPRESENTATION OR WARRANTY AS TO THE CONDITION OF THE DWELLING OR OTHER STRUCTURES ON THE PREMISES DESCRIBED HERELN, OR ANY ASPECT OF SUCH CONDITION, AND INTERESTED PARTIES ARE ADVISED AND ENCOURAGED TO MAKE i HEIR OWN INSPECTION OF THE PREMISES IN ORDER TO DETERMINE THE CONDITION THEREOF. MIAMI SHORES VILLAGE .BUILDING DEPARTMENT 305- 795 -2204 Buildi g Inspection Request Date Type Insp'n Permit No. Name ~ i iQ Address /( ‘1 Company Phone # Inspection Date Approved Correction Re- Insp'n Fee ❑ *7) MIAMI SHORES VILLAGE , BUILDING DEPARTMENT 305-795-2204 , Building Inspection Request Date .1.2 Phone # Inspection Date Approved Correction Re-Insp'n Fee • , Type Insp n .-.. Name ---- ;,'./.".:-- [ / 2 i./4; Address 1,/ ///' , i . --, , --- Company 'i ' - i /,/' <,.-'•.--/ ,., f`. 4',(-, Date Type Insp'n Permit No. Name Address Phone # Inspection Date Approved Correction Re- Insp'n Fee MIAMI SHORES VILLAG BUILDING DEPARTM 305- 795 -2204 Building Inspection Request )_O ,3L 'LA; Compa t! , 1 MIAMI SHORES VILLAGE • BUILDING DEPARTMENT 305- 795 -2204 Buil ing Inspection Request Date Jk ° Type Insp'n / O I P1 O3—lC5? Name //�� � c QJ Address IA/ / V — l 5 Permit No. Company rJ Phone # Inspection Date Approved Correction Re- Insp'n Fee MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305- 795 -2204 Building Inspection Request Date G- CC..� �. Type Insp'n ( rc i 1/ YP P� Permit No. PI o_c)- Name � ti Address I k ` i y t; r Company b' (:. q 15 Phone # l Inspection Date Approved Correction Re- Insp'n Fee , , ,;\ 11 2 ONING #2 MIAMI SHORES VILLAGE BUILDING DEPARTMENT 305 - 795 -2204 Building Inspection Request Date g Type Insp'n F tN0.\ \kgON 10 Permit No. q—. _0(f — 4' Name ,k t Company Vktt 1S ?Do\ Phone # "V - ` - Inspection Date 8t o 5 Approved Correction ❑ Re-Insp'n Fee ❑ 4 , Too 5 Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the building or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with. whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date 7- /7- , 19 e'? Owner's Name and Address ® 6 - 4r e` e�" " /e6' No. // / Street2XLt Registered Architect and/or Engineer erne and address of licensed contractor -State work to be done and purpose of building (by floors), state exterior colors (submit samples) IIA'Teedirn' 4 el< Location and legal description of lot to be built on: Lot Block /f® / S / ubdivision � I /? / 1 , o ty / 6 J / '' `mi l ✓ NE Street and Number where work is to be done `�` 7 / 7 .51 " m t /_374 c, 7 z)/,4' STATE OF FLORIDA COUNTY OF DADE. } SS. APPLICATION FOR BUILDING PERMIT MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT 6 . a0/1/c� and for no other purpose. New Building Remodeling Addition Repairs No. of Stories To be constructed of Kind of foundation Roof Covering (Estimated Total cost of improvements S � �® Amount of Permit S 04 Zone cubage required Plan Cubage Distance to next nearest building Size of Building Lot Maximum live load to be borne by each floor 1 hereby submit all plans and specifications for said building. All notices with reference to the building and its construction may be sent to The undersigned applicant for this building permit does hereby certify that he understands and accepts his bligatons as an employer of Labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement. and compliance from all contractors or sub - contractors employed by him in the work to be performed and on the site of the work such public notice or notices as are required by the Act. The undersigned a under this permit. as are licensed by Miami Shores Village. Remarks (Signed) Before me. the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally appeared and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the f.rego ±.g application, and that he did sign the same. and that all facts therein by him stated are true. Permit No. / "' ( � Date 1 Read, Sworn to and Subscribed before me. Disapproved (Signed) Building Inspector My Commission Expires PLANNING BOARD DATE Date complied with the provisions thereof, and will require similar s permit: and will post or cause to be posted for inspection ploy only ah subco rectors, on work to be performed Notary Public. State of Florida to me well known. Chairman Member Member Member Member Member Council Approved D ate Disapproved Date NOTE: A charge of $25.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board. A re- inspection fee of $25.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. PACE S. _ _ _ _ _ Et 69FT 1q" 5Co 11 145 1 C - { ' r f 7 ' ' H — : - - r ) fogC 3 mgpal .14." ef t 11tow1 P.e6 14" J2'I A L �u 3 =0' 1-o � — 4 - eot, (55T Cep) two AT qo° A rAeT. 6 <eokit9 S'RF1 ( WATo 29' PAQ ) 717/ II 40 PIFr ("2 WING FOR2L� . - LEA0 (' : /e%e 14Iu.) caoc zia 3 =0' 12 G1A 6A1Lt.Li5. tAr • &Y M21,016 W, ►,JG. 41'54X Vier uroat. :`r -gL. 1L 15PSF_ .. MOP jt? fir;* X150• u 3 I - � HAW 14 9 1 IV_ 11-t2' 8V-- DATE _ SHEET NO._ 1 _p 7 OF PROJECT NO. _7_Y - 1 l �n whin .rorz - N irgor4 UNWOern ccor ?a1 - No .N Q re p .4 00. 4, tenet EPITIO►J F 0 EFErZ - To GLA`c `( S1LTC. 1 SA0p GLA1 oR 61n.1 CLAYS M5✓p..1m fo 'ms DIUtt G61.6E SAUG I 54.1\1 i."2W)12 op Cl.A'i Y GAUD EIA FEIN TD (:)"A►Jo/ GI;%> ■■a. of? C 'A L Dt). o "r J '0k; To r.M y r 50 - IP 9,07.:r e Or. S 1 rt - T1T; SIL D(f'= rgTG►2mi►.>i,;IDIJ SHAL:. Eiz I05TALLE6 T h 15 / 4 ` , _ 5 7 1 4 / 1 !'h ,..; 11 PACE ENGINEERING — - -- - - - -- 2- %3 P.U.75 Oa 1 012111 oingor :.Irk a ) 9/a" pir6 WIP12 19r4a61J : IetIC , - 1. a, 0 aeILLC.JX124 wwo pR mof , A00 R- IrycIult ;16 acY. r2 &22 Porn A camp C k A,r 2 . mow E3OiLopr tNCM 0119timom .MOD 1St fl . NEKr CTi IPA 0c2 C1ACJii1.7,70 3. GeITd:1,L .v1(2 11,00 . IS raG5.61? •. rare 7 F ,� C►trm( 6 Pactr> A ,!; - a t 2 ' i4 x4 33 3'15p r— ..4' X 31 ® 75 ml4i Ml :c 5x•� � 31�- 45 45, 1,53 Vtu (5'54. 4 o) Fzntic h a s I 154 2 • A . mataliti A" 0 . 5 4 ) ( : 1 9 1•B5 q59 . d 9 1.8 i t ±� �4 •3b . w 4,2 3 Z '1.65 Far . IF)f6f c.& t 'L9 � 65/4 1 1 ." - 56 , b -R . 1 1,3e, L I+ V I d•3(0 4 3.5' deep 2 L I ?B �►b t71 (ow Attu). I merit Hv_Les— DATE -112 SHEET NO. - - OF. — PROJECT NO.— 181 lUcit vati r t4 ' m rrecciu.uk `t=oil ' b • I , lo l haai orl u & b".2' • .PACE ENGINEERING FW 6er }tamed :, tfiro I (. MAII or c'orrfet) 53 .. 8 _ i a. .. s' b • . . ' ' 1, i79 1.0' J ti co, b- l►o 1 lOr iPw1 d• `ails dZ- _ �•2 5 . > x x 0,2 >d -,,5. 1 P - S� e. d 21 =qI- $ d , 1 1 . LVdjECT 1 • 1 !. • d ° 2,5 �oC had boils • 11 — DATE _/ °Q6 _ SHEET NO._ _ OF — PROJECT NO. j•p 9 ` . 1202v C4.36 S.�W?tf sly - ' B. FORD CO. 1774 W. Flagler Street MIAMI 35, FLORIDA Telephones: 9 -3508 82 -0027 75 f• /,, n • • r I HEREBY CERTIFY that the attached sketvh represents a survey made under my direction and is bus • and correct to the best of my knowledge and belief. There are no encroachments bscypt as shown. , / � /' According to the Plat thereof as recorded in Plat Book Public Records of Dade County, Florida. For � , / �- REGISTERED LAND ) SURVEYORS 427 STATE OF FLORIDA Date • ti , at Page • •• • • • • • •••• • •• • • • • • •••• • • • • •••• • • • • • • • • • • •e • •••• • • • •• • • • •• • • • • •• • • • • • •• •• • • •••• •••• • • • • • • •••• •••• • • •• • • • •••• • • JOB NAME : RESIDENCE 1147NE97ST MIAMI SHORES, FL (A).5) --zio. •• • • • • • • • • • •••• •••• • • •••• • • • • • •••• •• •• • • • • • • • • •• • • • ••• • •••• • • • •••• •••• • • •••• • •• • • • • • • • • • •• • • • • • • •• • •• • • • • •••• • • NOT PART OF THIS PERMIT (VENTILATION) NOT PART OF THIS PERMIT LEFT KITCHEN BATH BEDROOM FRONT NOT PART OF THIS PERMIT GARAGE DINING 54' -10' REAR LIVING FAMILY ROOM NOT PART OF THIS PERMIT NOTE: E: MEAN ROOF HEIGHT : 11' -6" ROOF TYPE : 4:12 GROUND FLOOR r 1 J BEDROOM BEDROOM BATH RIGHT N 1 EXISTING STEEL COLUMN. REVISION: J 1 DATE: 07/14/06 SCALE: 3/16" a 1' DWG. BY: M.R.Z. JOB #: 565 1 of 5 J NOTE 1: WINDOW FRAMES/MULLION ANCHORAGE TO MAIN STRUCTURE SHALL BE IN STRICT ACCORDANCE WITH THE UNIT'S NOTICE OF ACCEPTANCE -REFER TO PRODUCTS CONTROLS. NOTE 2 : ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR PRODUCTS CONTROL N.O.A. DESIGN PRESSURES, AND SIZE ARE PART OF THIS PERMIT. ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. NOTE 3 : THE MAIN WIND FORCE RESISTING SYSTEM OF THE STRUCTURE(LE: BEAMS,COLUMNS,FRAMING,ETC.) SHALL BE DESIGNED TO WITHSTAND THE LOADS POSED BY THE GLAZING. NO CALCULATIONS HAVE BEEN PERFORMED TO VERIFY THEIR ADEQUACY. NOTE 4 : ALL EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR 1" X 2 -3/4" X 3/8" X 63" ALUMINUM TUBE MULLIONS BY PGT NOT PART OF THIS PERMIT FRONT ELEVATION 7 N • • • •• INTERIOR LITE: 1/8" H.S. GLASS • • •••• •••• • (1) 72" X 63" ( CENTER) • • " "� • • • "PW -701" ALUMINUM PICTURE WINDOW -LMI • • • N.O.A. : 03- 1105.01 EXISTING STEEL COLUMN. "A" 111" X 50 -5/8" (XOX)(1/3- 1/3 -1/3- CONFIGURATION) "B" M.O. 146" X 63" SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT (2) 37" X 63" (X)(LATERALS) N.O.A. : 05- 1129.11 SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT ZONE 5: +54.7 - 73.2 N.O.A. : 05- 1129.11 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS ZONE 4: +54.7 - 59.3 EXTERIOR LITE: 1/8" H.S.GLASS GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER EXTERIOR LITE: 1/8" H.S.GLASS INTERIOR LITE: 1/8" H.S. GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER •••• •• •• • • •' • ZONE 4: +54.7 -59.3 • • •••• • • •••• • GLAZING: 7/16" LAMINATED IMPACT RESISTANT GLASS • • •••• •••• EXTERIOR LITE: 3/16" H.S.GLASS • . ▪ •.. • .090 DUPONT BUTACITE OR SAFLEX KEEPSAFE MAXIMUM PVB • • • • INTERLAYER. • • • • •" INTERIOR LITE: 3/16" H.S.GLASS •••• NOTE: WINDOW UNITS SHALL BE MULLED TOGETHER USING: 1" X 2 -3/4" X 3/8 "X 63" ALUMINUM TUBE MULLIONS BY PGT. N.O.A.: 04- 0528.05. REVISION: 1 2 o a DATE: 07/14/06 SCALE: 3/16" c 1' DWG. BY: M.R.Z. JOB #: 565 2 of 5 • • • • • • • • • •• • • •• • • • • •••• •••• • • • •••• • • • •• • •••• • • •••• • • •• • • • • •• •••• • • EXISTING STEEL COLUMN. •••• • • •• • • • • • NOTE 1: WINDOW FRAMES/MULLION ANCHORAGE TO MAIN STRUCTURE SHALL BE IN STRICT ACCORDANCE WITH THE UNIT'S NOTICE OF ACCEPTANCE -REFER TO PRODUCTS CONTROLS. NOTE 2 : ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR PRODUCTS CONTROL N.O.A. DESIGN PRESSURES, AND SIZE ARE PART OF THIS PERMIT. ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. NOTE 3 : THE MAIN WIND FORCE RESISTING SYSTEM OF THE STRUCTURE(LE: BEAMS,COLUMNS,FRAMING,ETC.) SHALL BE DESIGNED TO WITHSTAND THE LOADS POSED BY THE GLAZING. NO CALCULATIONS HAVE BEEN PERFORMED TO VERIFY THEIR ADEQUACY. NOTE 4 : ALL EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR "Cl" 74" X 50- 5 /8 "(XX) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.O.A. : 05- 1129.11 ZONE 5: +54.7 -73.2 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/8" H.S.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LITE: 1/8" H.S. GLASS • "Ct'•'14 ".X 50- 5 /8 "(XX) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.Q.A. 05- 1129.11 • V,ONE 4: +54.7 -59.3 • • °LAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/8" H.S.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LITE: 1/8" H.S. GLASS 5 , RIGHT ELEVATION 1 1'-7° "D" 37" X 38- 3/8 "(X) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.O.A. : 05- 1129.11 ZONE 4: +54.7 -59.3 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/8" ANN.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LIIE: 1/8" H.S. GLASS "F" 74" X 63 "(XX) SERIES C- 740 ALUMINUM CASEMENT WINDOW-IMPACT N.O.A. : 05- 1129.11 ZONE 5: +54.7 -73.2 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/8" H.S.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LITE: 1/8" H.S. GLASS REVISION: 1 DATE: 07/14/06 SCALE: 3/16" = 1' DWG. BY: M.R.Z. JOB #: 565 3 of 5 / •••• •••• • • •••• • • •• .. • • • NOTE 1: WINDOW FRAMES/MULLION ANCHORAGE TO MAIN STRUCTURE SHALL BE IN STRICT ACCORDANCE WITH THE UNIT'S NOTICE OF ACCEPTANCE -REFER TO PRODUCTS CONTROLS. NOTE 2 : ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR PRODUCTS CONTROL N.O.A. DESIGN PRESSURES, AND SIZE ARE PART OF THIS PERMIT. ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. NOTE 3 : THE MAIN WIND FORCE RESISTING SYSTEM OF THE STRUCTURE(LE: BEAMS,COLUMNS,FRAMING,ETC.) SHALL BE DESIGNED TO WITHSTAND THE LOADS POSED BY THE GLAZING. NO CALCULATIONS HAVE BEEN PERFORMED TO VERIFY THEIR ADEQUACY. NOTE 4 ALL EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR X 31 -5a 0 REAR ELEVATION "El" 74" X 38- 3 /8 "(XX) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT • ;; N.Q.9. 1129.11 Zd 4'E $: +54.7 -73.2 GIB. 7JG: 5/16" LAMINATED IMPACT RESISTANT GLASS • • • • • • EXTERIOR LITE: 1/8" H.S.GLASS • .090 SOLUTIA OR DUPONT PVB INTERLAYER INTERIOR Lll'E: 1/8" H.S. GLASS NOT PART OF THIS PERMIT 0 "G" 141 - 13/16" X 80 "(XXX) SERIES "8000" ALUMINUM SLIDING GLASS DOOR- IMPACT N.O.A.: 04- 1020.03 ZONE 5: +51.3 - 66.4 GLAZING: 9/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/4" H.S.GLASS .075 VANCEVA INTERLAYER INTERIOR LITE: 1/4" H.S.GLASS NOTE : 2 -1/4" MINIMUM SILL RISER IS REQUIRED FOR THIS INSTALLATION. REVISION: J U 2 DATE: 07 /14/06 SCALE: 3/16" a 1' DWG. BY: M.R.Z. JOB 4*: 565 4 of 5 1 "H" 53 -1/8" X 38- 3 /8 "(XX) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.O.A. : 05- 1129.11 ZONE 4: +54.7 -59.3 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS • ' • • • . • • • EXTERIOR LITE: 1/8" ANN.GLASS • •.... • • .090 SOLUTIA OR DUPONT PVB INNERLAYER • • • .• • • • • • • .. .• •• .• • .• • • NOTE 1: WINDOW FRAMES/MULLION ANCHORAGE TO MAIN STRUCTURE SHALL BE IN STRICT ACCORDANCE WITH THE UNITS NOTICE OF ACCEPTANCE -REFER TO PRODUCTS CONTROLS. NOTE 2 : ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR PRODUCTS CONTROL N.O.A. DESIGN PRESSURES, AND SIZE ARE PART OF THIS PERMIT ALL OTHER OPENINGS ARE NOT PART OF THIS PERMIT. NOTE 3 : THE MAIN WIND FORCE RESISTING SYSTEM OF THE STRUCTURE(I.E: BEAMS,COLUMNS,FRAMING,ETC.) SHALL BE DESIGNED TO WITHSTAND THE LOADS POSED BY THE GLAZING. NO CALCULATIONS HAVE BEEN PERFORMED TO VERIFY THEIR ADEQUACY. NOTE 4 ALL EGRESS WINDOWS SHALL HAVE A SILL HEIGHT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR NOT PART OF THIS PERMIT (VENTILATION) NOT PART OF THIS PERMIT INTERIOR LITE: 1/8" H.S. GLASS 1:.74" X.3 .3 /8 "(XX) • • • • • • SER1ES•t- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.03:::::05-1129.11 5- 1129.11 • • • 704444.+54.7 -59.3 • • • • • GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS •••• LEFT ELEVATION EXTERIOR LITE: 1/8" ANN.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LITE: 1/8" H.S. GLASS c "D" 37" X 38- 3/8 "(X) SERIES C- 740 ALUMINUM CASEMENT WINDOW- IMPACT N.O.A. : 05- 1129.11 ZONE 4: +54.7 -59.3 GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS EXTERIOR LITE: 1/8" ANN.GLASS .090 SOLUTIA OR DUPONT PVB INNERLAYER INTERIOR LI 1/8" H.S. GLASS REVISION: DATE: 07 /14/06 SCALE: 3/16" a 1' DWG. BY: M.RZ. JOB #: 565 5 of 5