Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
MECHANICAL
Legal Description Historically Designated: Yes No Owner/Lessee / Te t / " 24 l/i Q Master Permit # Owner's Address /7 2I 975/ Phone (3Os) ZS -- 67E33 Contracting Co. /4720/4/ Address 7379 A1611 L , —y�'. Qualifier _ ak- 4 s' 4 a a .r d ez SS# Phone & YX /6Y ? State # C4 ° 57/67 Municipal # Competency # Ins. Co. Architect/E; giu^reez Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING ECHANICAL ROOFING PAVING FENCE SIGN WORK DESCR a1 >�N / / C6 �/(/ J/; , Square Ft. Estimated Cost (value) WARNING TO * WNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOU. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY rr EFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. PLIOIJC rant Of En 'l 1. or Condo President • v', ••• LUIS C. LLORET COMMISSION • D00527 t 9 ; EXPIRES AUG 26 2005 • B • ONDED 'HOUGH • ADVANWE NOTARY • .. 7• ••21 ( 7 Signature s of°owner an +otary as to - My Co •- ry9` "r71 - ]C Condo • r ident FEES: PERMIT ‘(-, RADON APPROVED: Zoning PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Jab Address 147. 91 Tax Folio 0 L- c1' Date C.C.F. My Commission Expires: NOTAR Building Notary as to Con ► : ctor or Owner- Builder LIS : O S MN 2 719 • EXPIRES M)( 26 2005 • • Boma TN • • ADVAMACO NOTARY • •ea• ••'•.•V• , ••Y• i ••••.•• f'••• A All Electrical , 2 F00 / TOTAL DUE OZ Data 2- Mechanical 2efi 4J /6i(..0 v Plumbing Structural Engineer Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Permit Number: ME2002 -159 Printed: 11/21/2002 Applicant: GAYLE Owner: PUMO JOB ADDRESS: 1147 NE 97 Contractor THERMAL MANAGEMENT Local Phone: Parcel # 1132050170040 fee is $50.00, which must be paid in advance before calling for an This Permit is granted to the contractor or builder named above to construct the build ordinances pertaining thereto and with the understanding that the work will be performer and approved by the proper municipal authorities. This Permit may be revoked at any t authorization. A further condition upon which this permit is granted is the understandint ordinances and regulations pertaining to the work covered hereby whether shown on till by his agents, servants or employees. sr d: In cor sideration of the issuance to me of this permit, I agree to perform the work covr= with the plans, drawings, statements or specifications submitted to the proper authoritiE G; myself, my agent, servnts or Harr- UiS x- 26 Z- Mechanical Permit PUMO GAYLE ST Contractor's Address: 7379 NW 54 ST Legal Description: REV PL MIAMI SHORES SEC 8 P 2-(11-* 60_ Permit Status: Approved Permit Expiration: 5/19/2003 Construction Value: Work: REPLACE SYSTEM (INSPECTOR) (Contractor or Bui Page 1 of 1 PB 43 -51 LOT 4 Total Fees: $0'80 Total Receipts: $0.00 If there is no permit package accessible on the job -site for inspartnrs to verify. .there will_b_eno inspections. Re- inspection BLK 180 LOT PAY TO THE ORDER OF Memo THERMAL MANAGEMENT BANK OF AMERICA, NA PH. 305- 471-0999 MMAML FL 33176 7379 NW 54TH STREET 6&3991870 MIAMI, FL 33168 D ate itin ;Vie. a/ W6 DOLLARS 8 1 Security IoaWree Included. Derails on back. i ci tyt. ti -S / iiv )---s tO/y, J(/ 4 Purn 1 :06 70039851: 00306 26 259 2511' XX 1531 Kitche n Garage 8" 256 cfm 102 cfm .1 Bath b "`Closet 9" Bed •om 1 • Sr 318 cfm Ljd NH 22 x 24 2000 cfm . Dinning _Family ' 282 cfm 9 " 113 cfm 6 " Sheet 1 Living Room 12" 113 cfm i Room 2 Bath 2 6 100 cfm A A Bedroo 246 cfm 10" 322 cfm Job #: Performed by CARLOS H for: Mark Pumo 1147 NE 87 St Miami Shores, FI 33138 Phone: 305 - 756 -6783 Thermal Management Inc. 7379 NW 54 St Miami, FI 33166 Phone: 305 -471 -0999 Fax: 305- 883 -4383 Scale: 1 : 102 Page 1 Right -Suite Residential J8 5.8.21 RSR31277 2002- Nov -15 17:05:56 D:1My Documents1Wrightsoft HVA... Name Dsn (Btuh) Dsn (cfm) Dsn (in H2O) Dsn FR Dia (in) Rect Sz (in) Duct Matl Actual Ln (ft) Equiv Ln (ft) Trnk Kitchen -A c 6378 256 0.42 0.209 VinIFIx Ox 0 X X X X X X X X X X LL LL LL LL LL LL LL LL LL U- > > > > > > > > > > 19.0 180.0 st1 Living Room h 1488 113 0.42 0.170 Peak AVF Ox 0 29.9 215.0 st2 Bedroom 1 -A h 4199 318 0.42 0.167 2000 Ox 0 34.7 215.0 st3 Bedroom 3-A h 4256 322 0.42 0.133 Ox 0 54.1 260.0 st2A Bath 2 c 2493 100 0.42 0.136 CD Ox 0 47.3 260.0 st2A Room 2 -A h 3252 246 0.42 0.134 Ox 0 50.4 260.0 st2A Living Room -A h 1488 113 0.42 0.169 Ox 0 31.4 215.0 st2 Dinning s Family h 3725 282 0.42 0.171 Ox 0 28.8 215.0 st2 Dinning & Family -A h 3725 282 0.42 0.170 Ox 0 29.6 215.0 st2 Bath 1 c 2547 102 0.42 0.171 Ox 0 29.1 215.0 st3 Name Trunk Type Htg (cfm) Clg (cfm) Vel (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st2A Peak AVF 662 617 843 N CO O N a- a- r N 0 x 0 VinIFIx st2 st2 Peak AVF 1451 1347 821 0 x 0 VinIFIx st1 st3 Peak AVF 420 396 770 0 x 0 VinIFIx st1 st1 Peak AVF 2000 2000 655 10 x 44 ShtMetl 7379 NW 54 St, Miami, FI 33166 Phone: 305 -471 -0999 Fax: 305 -885 sail: THERMAL W ?NT @YAHOO.COM Web: WWW.THERMALMNGT.COM P t Information External Static Pressure: Pressure Losses: Available Static Pressure: Friction Rate: Actual AVF: Total Effective Length (TEL): Duct System Summary Entire House Thermal Management Inc. For: Mark Pumo 1147 NE 87 St, Miami Shores, FI 33138 Phone: 305 - 756 -6783 wnghtsoft Right -Suite Residential J8 5.8.21 RSR31277 ACM D: My Documents\Wrightsoft HVACWIarkPumo.rrp Calc = MJ8 Orientation = N HEATING 0.50 in H2O 0.00 in H2O 0.50 in H2O 0.133 in /100ft 2000 cfm 377 ft COOLING 0.50 in H2O 0.00 in H2O 0.50 in H2O 0.133 in /100ft 2000 cfm Job: Date: 11/15/02 By: CARLOS H Supply Branch Detail Table Supply Trunk Detail Table 2002 - Nov -15 17:05:00 Page 1 Name 'Diffus ! Sz (in) Design AVF (cfm) Design (in H2O) Design FR Vel (fpm) Dia (in) Rect Sz (in) Stud /Joist Opening (in) Duct Matl Trunk rb0 0 x 0 2000 0.08 0.133 545 24 24 x 22 ShMt Return Branch Detail Table wnghtsoft Right -Suite Residential J8 5.8.21 RSR31277 2002- Nov -15 17:05:00 � � D:\My Documents\Wrightsoft HVACWIarkPumo.rrp Calc = MJ8 Orientation = N Page 2 Component Btuh /ft Btuh % of Toad Walls 3.3 4342 10.0 Windows 61.3 19597 45.1 Doors 9.3 195 0.4 Ceilings 4.1 7371 16.9 Floors 0.0 0 0.0 Infiltration 1.1 1580 3.6 Ducts 6255 14.4 Ventilation 608 1.4 Internal gains 3550 8.2 Blower 0 0.0 Total 43498 100.0 Component Btuh /ft Btuh % of Toad Walls 2.8 3739 16.0 Windows 21.7 6934 29.7 Doors 5.2 109 0.5 Ceilings 1.4 2490 10.7 Floors 2.5 4437 19.0 Infiltration 2.1 3175 13.6 Ducts 1821 7.8 Piping 0 0.0 Humidification 0 0.0 Ventilation 611 2.6 Total 23317 100.0 7379 NW 54 St, Miami, FI 33166 Phone: 305 - 471 -0999 Fax: 305-883-4383 Email: THERMAL_MANAGEMENT @YAHOO.COM Web: WWW.THERMALMNGT.COM Pro'ect Information For: Design Conditions Location: Miami, Intl AP, FL, US Elevation: 13 ft Latitude: 26 °N Outdoor: Dry bulb ( °F) Daily range ( °F) Wet bulb ( °F) Wind speed (mph) Heating 50 Hea tin. Overall U -value = 0.179 Btuh /ft? °F Building Analysis Entire House Thermal Management Inc. Mark Pumo 1147 NE 87 St, Miami Shores, FI 33138 Phone: 305 - 756 -6783 15.0 Cooling 90 11 77 (L ) 7.5 wng htsOft Right -Suite Residential J8 5.8.21 RSR31277 D:1My Documents \Wrightsoft HVAC\MarkPumo.np Calc = MJ8 Orientation = N Indoor: Heating Indoor temperature ( °F) 70 Design TD ( °F) 20 Relative humidity ( %) 30 Moisture difference (gr /Ib) -10.2 Infiltration: Method Simplified Construction quality Average Fireplaces 0 Conlin • Job: Date: 11/15/02 By: CARLOS H Other Cooling 70 20 50 65.9 2002 - Nov -15 17:05:00 Page 1 7379 NW 54 St, Miami, FI 33166 Phone: 305-471-0999 Fax: 305- 883 -4383 Email: THERMAL_MANAGEMENTWAHOO.COM Web: WWW.THERMALMNGT.COM Pro'ect Information Desi • n Information Outside db Inside db Design TD Winter Design Conditions Building heat loss Ventilation air Ventilation air loss Design heat load Space thermostat For: Mark Pumo 1147 NE 87 St, Miami Shores, FI 33138 Phone: 305 - 756 -6783 Notes: Project Summary Entire House Thermal Management Inc. Infiltration Weather: Miami, Int'I AP, FL , US 50 °F 70 °F 20 °F Job: Date: 11/15/02 By: CARLOS H Summer Design Conditions Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 °F 70 °F 20 °F L 50 % 66 gr /Ib Heating Summary Sensible Cooling Equipment Load Sizing 22706 Btuh Structure 42890 Btuh 28 cfm Ventilation 608 Btuh 611 Btuh Design temperature swing 3.0 °F 23317 Btuh Use mfg. data n Rate /swing multiplier 0.95 Total sens. equip. load 41280 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Internal gains 1000 Btuh Ventilation 1245 Btuh Heating Cooling Infiltration 3233 Btuh Area (ft 1805 1805 Total latent equip. load 6239 Btuh Volume (ft 14440 14440 Air changes /hour 0.60 0.30 Total equipment Toad 47518 Btuh Equiv. AVF (cfm) 144 72 Req. total capacity at 0.70 SHR 4.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Rheem Trade Trade Rheem RKKA Series n/a RKKA -A060Y Efficiency 100 EFF Efficiency 10.1 SEER Heating input 0 Btuh Sensible cooling 42000 Btuh Heating output 23317 Btuh Latent cooling 18000 Btuh Heating temp rise 11 °F Total cooling 60000 Btuh Actual heating fan 2000 cfm Actual cooling fan 2000 cfm Heating air flow factor 0.088 cfm /Btuh Cooling air flow factor 0.047 cfm /Btuh Load sensible heat ratio 87 % Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Wnghtsc ft Right-Suite Residential J8 5.8.21 RSR31277 2002 - Nov -15 17:05:00 ACCN D:\My Documents\Wrightsoft HVACWIarkPumo.rrp Calc = MJ8 Orientation = N Page 1 l . N M V .11 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 188.0 ft 8.0 ft d 1805.0 ft Kitchen 15.0 ft 8.0 ft heat/cool 12.0 x 15.0 ft 180.0 ft Ty Construction number U -value Btuh/ft -- °F) Or HIM (Btuh/ft Area ft') or perimeter (ft) Load (Btuh) Area ft or perimeter (ft) Load (Btuh) Heat Cool Gross N/P /S Heat Cool Gross N/P /S Heat Cool 6 13BB-Oocms 0.109 2.18 2.39 264 196 427 468 0 0 . 1A -clob 1.080 21.60 37.22 24 0 518 893 0 0 . 1A -clomd 1.270 25.40 41.00 44 0 1118 1804 0 C 13BB-Oocms 0.109 2.18 2.39 352 284 619 678 0 C 11 1A -clob 1.080 21.60 95.56 88 0 1469 6498 0 0 13AA -Ooc 0.584 11.88 15.53 56 44 514 684 0 0 1A -clob 1.080 21.60 95.56 12 0 259 1147 0 0 13BB-Oocms 0.109 2.18 2.39 424 283 617 676 0 0 1A -clob 1.080 21.60 42.32 72 72 1555 2824 0 0 1A -clob 1.080 21.60 40.32 48 48 1037 1786 0 0 11E0 0.260 5.20 9.28 21 21 109 195 0 0 13BB-Oocms 0.109 2.18 2.39 344 304 663 726 120 10 22 248 1A -clob 1.080 21.60 95.56 24 0 511 2282 0 0 1D-c2ob 0.650 13.00 77.32 16 0 208 1237 16 20 1237 13AA -Ooc 0.584 11.68 15.53 64 52 607 808 0 0 1A -clob 1.080 21.60 95.56 12 0 259 1147 0 0 12C -Osw 0.091 1.82 1.89 160 160 291 303 96 9 17 182 16B -13ad 0.070 1.40 4.14 1653 1653 2314 6850 180 18 25 746 16B -15ad 0.061 1.22 3.61 112 112 137 404 0 0 16B -19ad 0.049 0.98 2.90 40 40 39 116 0 0 22A -tpm 1.180 23.60 0.00 1749 188 4437 0 180 1 354 0 LL 22A -tph 1.358 27.16 0.00 58 0 0 0 0 0 Envelope loss /gain 17710 31505 1215 2413 12 a) Infiltration 3175 1580 253 126 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 115 1 230 Appliances (dJ 1200 2 240 2 2400 Less external load 0 0 0 Less transfer 0 0 0 Redistribution 0 16 47 14 Subtotal 20885 36634 1485 5216 15 Duct loads 9% 17% 1821 625 15% 22% 226 1162 Total room load 22706 42890 1711 6378 Air required (cfrn) 2000 2000 151 297 Right -J8 Worksheet Entire House Thermal Management Inc. 7379 NW 54 St, Miami, Fl 33166 Phone: 305 - 471 -0999 Fax: 305- 883-4383 Email: THERMAL MANAGEMENTWAHOO.COM Web: WWW.THERMALMNGT.COM Printout certified by ACCA to meet all requirements of Manual J 8th Ed. NA 'rug Right-Suite Residential J8 5.8.21 RSR31277 D:1My Documents\Wrightsoft HVAC\MarkPumo.rrp Calc = MJ8 Orientation = N Job: Date: 11/15/02 By: CARLOS H 2002 - Nov -15 17:05:00 Page 1 I , —c c.) v u, I Room name Exposed wall Ceiling height Room dimensions Room area Dinning 8.0 ft 25 375.0 ft Bath 1 8.0 ft 8.0 ft heat/cool 5.0 x 8.0 ft 40.0 ft Ty Construction number U -value (Btuh/ft - °F) Or HTM Area ft') perimeter Load Area ft perimeter (ft) Load (Btuh ) Heat Cool Gross N/I Gross J N /P /S Heat Cool 6 1388 -0ocros 0.109 2.18 2.39 201 O 00000 O O O O 000014 . 1A-c1 ob 1.080 21.60 37.22 0 . 1A -clomd 1.270 25.40 41.00 1118 13B13-0ocros 0.109 2.18 2.39 78 11 1A -clob 1.080 21.60 95.56 432 13AA -Ooc 0.584 11.68 15.53 0 IA-cl ob 1.080 21.60 95.56 0 13BB -0ocros 0.109 1A -clob 1.080 21.60 42.32 0 1A -clob 1.080 21.60 40.32 0 11E0 0.260 13BB-Oocrns 0.109 1A -clob 1.080 21.60 95.56 0 1D -c2ob 0.650 13.00 77.32 0 13AA -Ooc 0.584 11.68 15.53 0 60 80 1A -cl ob 1.080 21.60 95.56 0 25 114 12C -Osw 0.091 1.82 1.89 116 16B -13ad 0.070 1.40 4.14 525 16B -15ad 0.061 16B -19ad 0.049 0.98 2.90 0 3 11 22A -tpm 1.180 23.60 0.00 566 18 T 22A -tph 1.358 27.16 0.00 a 0 0 O 0 Envelope loss/gain 3037 5696 1095 2071 12 a) Infiltration 405 202 135 67 b) Ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 18 54 14 Subtotal 3442 5897 1248 2192 15 Duct loads 8% 16% 283 956 8% 16% 103 355 Total room load 3725 6854 1350 2547 Air required (cfm) 328 320 119 119 Right -J8 Worksheet Entire House Thermal Management Inc. 7379 NW 54 St, Miami, F133166 Phone: 305.471 -0999 Fay 305-883-4383 - THERMAL - _ Web: WWW.THERMALMNGT.COM Job: Date: 11 115102 By: CARLOS H Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,r ightsOR Right-Suite Residential J8 5.8.21 RSR31277 ACCZ• D:UMy DocumentslWrightsoft HVAC1MarkPumo.rrp Cale = MJ8 Orientation = N 2002 - Nov -15 17:05:00 Page 2 I .-N Room name Exposed wall Ceiling height Room dimensions Room area Closet 0.0 ft 7.0 8.0 ft 56.0 fr Bedroom 1 40.0 ft 8.0 ft heat/cool 1.0 x 264.0 ft 264.0 ft Ty Construction number U -value (Btuh/ft2 -- °F) Or Area ft') perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross j N /P /S Heat Cool 6 . . 11 OTOT0_170_10,000.„ 1 13BB-Oocms 1A -clob 1A -clomd 1366 -0ocros 1A -clob 13AA -Ooc 1A -c1 ob 13BB -Oocros 1A -clob 1A -clob 11E0 13BB-Oocms 1A -clob 1D-c2ob 13AA -Ooc 1A -clob 12C -Osw 16B -13ad 16B -15ad 168 -19ad 22A -tpm 22A -tph 0.109 1.080 1.270 0.109 1.080 0.584 1.080 0.109 1.080 1.080 0.260 0.109 1.080 0.650 0.584 1.080 0.091 0.070 0.061 0.049 1.180 1.358 C CC w ww w www N $$ 2.18 21.60 25.40 2.18 11.68 2.18 21.60 21.60 5.20 2.18 21.60 13.00 11.68 21.60 1.82 1.40 1.22 0.98 23.60 27.16 2.39 37.22 41.00 2.39 15.53 2.39 42.32 40.32 9.28 2.39 95,56 77.32 15.53 95.56 1.89 4.14 3.61 2.90 0.00 0.00 000 000000000000000000 (O 0 0 0 000000000000000000 f0 O O O 000000000000000000 N 0 0 0 0 000 N0000lO000 OOOO•O O/O NM NN N N , , 1 A 000 0 O O 0 0 0 0? 000 O 0001¼) 0 0 0 157 183 778 227 511 37 944 0 0 0 0 0 0 172 0 0 0 0 0 0 201 1412 0 0 0 0 249 2262 0 0 0 0 1094 0 0 0 0 Envelope loss/gain 68 202 3170 5389 12 a) Infiltration b) Ventilation 0 0 0 0 676 0 336 0 13 14 15 Internal gains: Occupants @ 230 Appliances @ 1200 Less external load Less transfer Redistribution Subtotal Duct loads 0 0 8% 16% 00°000 0000N00 0 2 0 8% 16% 0 0 34 3880 319 460 0 0 0 101 6286 1019 Total room load Air required (cfrn) 0 0 0 0 4199 370 7305 341 Right -J8 Worksheet Entire House Thermal Management Inc. 7379 NW 54 St. Miami, Fl 33166 Phone: 305- 471 -0999 Far 305483-4383 THERM -- ---- Web: WWW.THERMALMNGT.COM Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wngl'ltsot t Right-Suite Residential J8 5.8.21 RSR31277 ACM D:1My Documents1Wrightsoft HVACWtarkPumo.np Calc = MJ8 Orientation = N Job: Date: 11115/02 By: CARLOS H 2002- Nov-15 17:05:00 Page 3 NMV bI Room name Exposed wall Ceiling height Room dimensions Room area Living Room 22.0 ft 8.0 ft heat/cool 22.0 x 15.0 ft 330.0 ft' Room 2 30.0 ft 8.0 ft heat/cool 16.0 x 14.0 ft 224.0 ft Ty Construction number U -value (Btuh/ft2.') Or HTM (Btuh/ft ) Area R or perimeter (ft) Load (Btuh) Area ft or perimeter (ft) Load (Btuh) Heat Cool Gross N/P /S Heat Cool Gross N /P /S Heat Cool 6 . . 11 1 13BB -Oocros 1A -clob 1A -clomd 13BB -Oocros 1Ac1ob 13AA -Ooc 1A -clob 13BB-Oocms 1A -clob 1A -c1ob 11E0 1313B-Oocros 1Aclob 1D-c2ob 13AA -Ooc 1Aclob 12C -Osw 16B -13ad 16B -15ad 16B -19ad 22A -tpm 22A -tph 0.109 1.080 1.270 0.109 1.080 0.584 1.080 0.109 1.080 1.080 0.260 0.109 1.080 0.650 0.584 1.080 0.091 0.070 0.061 0.049 1.180 1.358 C caw GI C/ N N N N 01 2.18 21.60 25.40 2.18 21.60 11.68 21.60 2.18 21.60 21.60 5.20 2.18 21.60 13.00 11.68 21.60 1.82 1.40 1.22 0.98 23.60 27.16 2.39 41.00 2.39 95.56 15.53 95.56 2.39 42.32 40.32 9.28 2.39 95.56 77.32 15.53 95.56 1.89 4.14 3.61 2.90 0.00 0.00 17 4 21 33 33 00000001 000000000 O N fV 0000000 cD 00.-00000000000 N M M M M O 0 0 0 0 0 0 0 233 0 1037 109 0 0 0 0 0 0 462 0 0 519 0 25 178 19 136 128 24 0 112 24 0 0 0 0 0 0 0 0 0 0 0 0 224 0 0 224 0 00 o 0000000000000 0000 N 22 24 51 89 19 21 51 229 31 92 70 Envelope loss /gain 2360 3604 2477 4573 12 a) Infiltration b) Ventilation 372 0 185 0 507 0 252 0 13 14 15 Internal gains: Occupants @ 230 Appliances @ 1200 Less extemal load Less transfer Redistribution Subtotal Dud loads 0 0 8% 16% 0 0 18 2750 226 0000V C) ) c) M 1 0 8% 16% 0 0 21 3005 247 230 0 0 0 82 5117 830 Total room load Air required (dm) 2976 282 4466 208 3252 286 5947 277 Right -J8 Worksheet Entire House Thermal Management Inc. 7379 NW 54 St, Miami, Fl 33166 Phone: 305-471-0999 Fax: 305- 883 -4383 il THERMAL MANAGEMENT©YAHC - - -. - Web: WWW.THERMALMNGT.COM Job: Date: 11/15/02 By: CARLOS H Printout certified by ACCA to meet all requirements of Manual J 8th Ed. w1 Flt5of Right-Suite Residential J8 5.8.21 RSR31277 <.t;a D:\My Documents \Wrightsoft HVAC\MarkPumo.rrp Calc = MJ8 Orientation = N 2002 - Nov -15 17:05:00 Page 4 .-Nt7CUfl Room name Exposed wall Ceiling height Room dimensions Room area Bath 2 7.0 ft 8.0 ft heat/cool 8.0 x 7.0 ft 56.0 ft Bedroom 3 42.0 ft 8.0 ft heat/cool 16.0 x 14.0 ft 224.0 ft Ty Construction number U -value (Btuh /ft - °F) Or HTM Area ft perimeter (ft) Load (Btuh) Area ft or perimeter (ft) Load (Btuh) Heat Cool Gross N /P /S Heat Cool Gross N /P /S Heat Cool 6 13BB -Oocros 0.109 2.18 2.39 O 0000.r 0000 0000 000010 01∎0 V' N 0 0 . 1 A-c1 ob 1.080 21.60 37.22 0 0 . 1A -c1omd 1.270 25.40 41.00 0 0 13BB-Oocms 0.109 2.18 2.39 112 8 192 21 11 1A -clob 1.080 21.60 95.56 24 518 229 13AA -Ooc 0.584 11.68 15.53 51 68 0 0 1A -clob 1.080 21.60 95.56 25 114 0 0 13BB-Oocms 0.109 2.18 2.39 128 9 201 22 1A -c1ob 1.080 21.60 42.32 36 3 77 141 1A -clob 1.080 21.60 40.32 0 11E0 0.260 5.20 9.28 0 13BB -Oocros 0.109 2.18 2.39 96 9 20 22 1A -clob 1.080 21.60 95.56 0 1D -c2ob 0.650 13.00 77.32 0 13AA -Ooc 0.584 11.68 15.53 0 1A-c1 ob 1.080 21.60 95.56 0 12C -Osw 0.091 1.82 1.89 0 16B -13ad 0.070 1.40 4.14 224 22 31 92 16B -15ad 0.061 1.22 3.61 6 20 0 16B -19ad 0.049 0.98 2.90 0 22A -tpm 1.180 23.60 0.00 16 224 4 991 LL 22A -tph 1.358 27.16 0.00 O 0 0 Envelope loss/gain 1007 2032 3202 5292 12 a) Infiltration 118 59 709 353 b) Ventilation 0 0 0 0 13 Internal gains: Occupants © 230 0 0 1 230 Appliances @ 1200 0 0 0 0 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 18 54 21 62 14 Subtotal 1143 2145 3933 5937 15 Duct loads 8% 16% 94 348 8% 16% 323 963 Total room load 1237 2493 4256 6900 Air required (cfm) 109 116 375 322 Right -J8 Worksheet Entire House Thermal Management Inc. 7379 NW 54 St, Miami, Fl 33166 Phone: 305 - 471 -0999 Fay 305-883-4383 Email: THERMAL_MANAGEMENT@YAHOO.COM Web: wWW.THERMALMNGT.COM Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 1� wr Right-Suite Residential J8 5.8.21 RSR31277 .4CCl• D:\My Documents \Wrightsoft HVACWIarkPumo.rrp Cale = MJ8 Orientation = N Job: Date: 11115102 By: CARLOS H 2002 - Nov -15 17:05:00 Page 5 N o7 t 0 Room name Exposed wall Ceiling height Room dimensions Room area Hall 0.0 ft 8.0 ft heat/cool 8.0 x 7.0 ft Ty Construction U -value Or Load Area Load number Btuh/ft' - °F) (Btuh) or perimeter Heat Cool Gross N/P/S eat Cool Gross N /P /S Heat Cool 6 13BB-Oocms 0.109 2.18 2.39 . 1A -clob 1.080 21.60 37.22 . 1A -c1omd 1.270 25.40 41.00 13BB-Oocms 0.109 2.18 2.39 11 1A -clob 1.080 21.60 95.56 13AA -0oc 0.584 11.68 15.53 1A -c1ob 1.080 21.60 95.56 13BB-Oocms 0.109 2.18 2.39 1A -clob 1.080 21.60 42.32 1A -clob 1.080 21.60 40.32 11E0 0.260 5.20 9.28 13BB-Oocms 0.109 2.18 2.39 1A-c1 ob 1.080 21.60 95.56 1D-c2ob 0.650 13.00 77.32 13AA -Ooc 0.584 11.68 15.53 1A -clob 1.080 21.60 95.56 12C -Osw 0.091 1.82 1.89 16B -13ad 0.070 1.40 4.14 16B -15ad 0.061 1.22 3.61 16B -19ad 0.049 0.98 2.90 22A -tpm 1.180 23.60 0.00 u- 22A -tph 1.358 27.16 0.00 0 O O Envelope loss/gain 78 232 12 a) Infiltration 0 0 b) Ventilation 0 0 13 Internal gains: Occupants ( 230 0 0000 M 00 N Appliances @ 1200 0 Less extemal load Less transfer O Redistribution 14 Subtotal 15 Duct loads 8% 16% Total room load 0 0 Air required (cfm) 0 0 Right -J8 Worksheet Entire House Thermal Management Inc. Job: Date: 11/15/02 By: CARLOS H 7379 NW 54 St, Miami, Fl 33166 °` 305 -471 -0999 Fax - ENT@YAHOO.COM Web: WWW.THERMALMNGT.COM Printout certified by ACCA to meet all requirements of Manual J 8th Ed. . r-ug1 - 1tsc Ft Right-Suite Residential J8 5.8.21 RSR31277 D:1My Documents\Wrightsoft HVACWarkPumo.rrp Calc = MJ8 Orientation = N 2002 - Nov -15 17:05:00 Page 6 Contractor MARS POOLS Local Phone: 954 - 214 -2844 Parcel # 1132050170040 Signed: (INSPECTOR) Mechanical Permit Miami Shores Village 10050 NE 2nd Avenue Phone: 305 - 795 -2204 Permit Number: MC2005 -41 Printed: 4/18/2005 Applicant: GAYLE PUMO Owner: PUMO GAYLE JOB ADDRESS: 1147 NE 97 ST Contractor's Address: 1000 E. ATLANTIC #11 Legal Description: REV PL MIAMI SHORES SEC 8 Fees: Description Amount FEE2005 -5001 Building Fee $100.00 FEE2005 -5002 CCF $0.60 FEE2005 -5003 Training and Education Fee $0.20 FEE2005 -5004 Technology Fee $2.50 FEE2005 -5005 Submittal Fee ($50.00) Total Fees: $53.30 Total Fees: $53.30 Total Receipts: $0.00 Permit Status: APPROVED Permit Expiration: 9/26/2005 Construction Value: $800.00 Work: POOL HEATER [2R 19 PM Page 1 of 1 PB 43 -51 LOT 4 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responisibility for all work done by either myself, my agent, servants or employes. Signed: (Contractor or Builder) BY: BLK 180 LOT BUILDING PERMIT APPLICATION FBC 2001 Permit Type (circle): Building Owner's Name (Fee Simple Titleholder) Owner's Address 1147 4' CityAi/71w $h'95 State Tenant/Lessee Name Job Address (where the work is being done) f /(/) 4'g 97 5 re 9 f City _ Miami Shores Village County Miami -Dade Zip Is Building Historically Designated YES NO Contractor's Company Name /'� 2 � /5 Contractor's Address JOOd ////0„),-, City / .1 ,get? 6- State Zip .� � d� Qualifier State Certificate or Registration No. if, 2. 5'25 5' 5 ` 2 S 0 Certificate of Competency No. O 2 ° / a Via " /J Architect /Engineer's Name (if applicable) Phone # $ Value of Work For this Permit Type of Work: ❑Addition /"`� ❑Alteration Describe Work: ac. / gP.,u/e--' C� 1)3 Submittal Fe,e $ Notary Scanning S Code Enforcement $ Structural Plan Review. $ Total Fee Now Due $ (Continued on opposite side) * * * ** * * * * * * * * * * * ** Training /Education Fee $ Radon $ Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Permit Fee $ , e "' ; mQ ❑New Zip 31 F' Master Permit No. Phone # Permit No. j" C Electrical Plumbing Mechanical Roofing Phone # ; Of 7 S 7ffi Phone # 9 `ti Z / >' 2- Piz Square Footage Of Work: ❑ Repair /Replace * *******Fees****************************** it& LC 6 CCF $ t ), . Zoning Technology Fee $ Bond $ CO /CC ['Demolition '4 4/ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: 1 certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature yz.g.„ewit../z/ Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 2 Y day of ,20 ,by , day of / j ? c x e , 20 0 C, by ilfe N/ who is personally known to me or who has produced w o is personally known to me or who has produced As identification and who did take an oath. as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: // s +•• ". " "' KI Sign: Sign: . on is DD0103451 % Bonded through I_ Print: Print: w (800- 432�2...� ..�. -- ' - 'a ie iisur My Commission Expires: My Commission Ex'ft s ***************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** *********^*********** * * * * * * * 1: * * * * * * * * * * * * * * * * * * * * ** APPLICATION APPROVED BY: i� /� Plans Examiner Engineer Zoning Chc 05/13/03