Loading...
ROOFINGMIAMI SHORES VBLLAEE BUILDING INSPECTION DEPARTMENT APPLICATION FOR E U LDB G PE Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. New Building To be constructed of Remodeling Kind of foundation therein by him stated are true. Permit No. .____ Date Disapproved __..... __..� Date_.' (Signed) 12 /Q Building Inspecto Date P NINO BOARD DATE Chairman Member Member ...... Member Owner's Name and AddressL McCarthy Rea. -J i..ad1e .. i:To...$.6.Lll...._ . Stzr a . 3.1,JLSl.� Registered Architect and /or Engineer Name and address of licensed contractor Andrews Roofing U Im,p.:.._..C.A.4_._.. QQ_L.— .1.1.t.b....A.ve.a t17 �... Location and legal description of lot to be built on: Lot Block Subdivision Street and Number where work is to be done 1122 N. E. g 7 tit S . t_ purpose of building (by noors)re - roof roof over 2 bathrooms S State wor o be done an at E. en o douse using 1 ply 30# felt, 3 15# felts E pea rock. Replace fascia board on f x an_t.... and for aso other purpose. in rear Addition Iiepaira.r e - r.Q.o L_.. No. of Stories 1 Roof Covering grave 1 Estimated Total cost of improvements $ $.31 ._.0.0 amount of Permit r. 5.00 Zone cubage required __._.______.. _Plan Cubage Distance to next nearest building. Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to Andrew Roofing & Imp. Co, 43.0._0._..E.. 1.1.t.h...Ave.._ Bia.e 33.013......... The undersigned applicant for this building pennit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the eror, such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontrdctors,,n work t ?rformedunder this pennit, as are licensed by Miami Shores Village. Remarks..._ (Signed) 4 STATE OF FLORIDA, COUNTY OF DADE. j SS. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared Read, Sworn to and Subscribed before me. Member Member to me well lifficr.vvn, and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the mane. and that al! facts Notary Public, State of Florida My Commission Expires Council Approved Date Disapprov Date NOTE: A charge of $1.00 will be made for making corrections or changes to this application after epprova8 has he.en obtain w.•i Trcrin the Planning Board. A re- inspection fee of $1.00 will be charged when such re-inspection is =do necessary by trapretpv notice for iassgrctirtn rs7 faulty materials and /or workmanship. Chairman . _ Member . Member Council Approved. ..... MIAMI LM[ \11 LL BUIL APPLICATMN Owner's Name and Address. Morton Hill Registered Architect and/or Engineer._ . ING ONSPEC7MN [1:) AMTMENT GE Eamirr ‘9 / Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Date OCt 0 6th 67 19 No. XXO 112 s 2 tzeet.. E. E. 97th Name and address of licensed contractorLR lag Roofing & Tile Co o2 Inc . 573J'!. 14. 71st Street Miami Fla. 13151 Location and legal description of lot to be built on: Lo. Block Subdivision. Street and Number where work is to be done 1122N E 97 th Street Shores, Florida State work to be done and purpose of building (by floors) Partial tear off shingle tile roof° Replace with 1-30# 'ell, tin capped, 1-90# slate hot mopped to 301/ felt and cover with n layer of standard white cement thick butt shinple tiles and for no other purpose. New Building Remodeling . Addition Repairs.. No. of Stories 1 To be constructed of Kind of foundation .. . ....... Roof Covering Cement tiles Estimated Total cost of improvements $..4 P., 00 Amount of Permit Zone cubage required _Plan Cubage Size of Building Lot. Distance to next nearest building Maximum live load to be borne by each floor_ I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to__ _ The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub-contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such ubcontracto , on work to be performed under this permit, as are licensed by Miami Shores Village. Remarks (Signed)_ /, ./ STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true. Permit No 4--- g 7 Date. /e -/e) ._ e ' Read, Sworn to and Subscribed before me. Disapproved ____ _._.,._ ,.....;- Date (Signed) ______-_---v. Notary Public, State of Florida Building Insp or My Commission Expires to me well known, PLANNING BOARD DATE Member Member Member . _Date Disapproved Date NOTE: A charge of $1.00 will be made for making corrections or changes io this application after approval has been obtained from the Planning Board. A re-inspection fee of 51.00 will be charged when sL.-h re-inspection is made necessary by improper notice for inspection or faulty materials and/or workmanship. APPLICATION FOR BUILDING PERMIT Application is hereby made for the approval of the detailed state..re•nt of the plans and specifications herewith submitted for the build • inc or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida. and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the iuilding Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. D ate..._.....!..1_.._. — Z. .._ .�..._.__..._... 19.. r��j. Owner's Name and Address ....... fl R y\l) _. No...._.l��.GL .. Street 27 Registered Architect and /or Engineer ,,.,. ,..•••... »,.t.,.t•,• „t...<. CT. ,.,<. `ame and a css o license contractor .. 7/1-/?l..t'. � .....�..i�.l.!1.R. .Q6:6/-?* Q6: P..... �I 3 occa ion a nd lc�l descriptio of l ot to be built on: i /9R p � r _ r/ Lot Block er i Subdivision. , Street and Number where work is to be State work to be done and purpose of building (by floors .... �QE�... - ` t` 60. i - z Date Date Building Inspector MIAMI SHORES VILLAGE 7S7 1"7 BUILDING INSPECTION DEPARTMENT done .).1?�c :_. ID�1 Ciiair:r an M1crr.bcr Member .. . - -- ....__..__._..__._ ..... Council Approved NOTE: A charge of ° $1.00 will be made for making corrections the Planning Board. A re- inspection fee of $1.00 will be charged materials anti /or workmanship. Member Member Member Date Disapproved �. and for no other purpose. New Building Remodeling Addition Repairs .tom No. of Stories,,..........._ ... _ To be constructed of Kind of foundation Roof Covering ✓ `... . . f C / lo 'l Q Estimate Total cost of improvements $ L Amount of Permit $, )� Zone cubage required .Plan Cubage Distance .to next nearest building Size of Building Lot Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may be sent to. The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied % %ith the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such ntractors, on work to be perfprmed under this pcnnit, as are licensed by Miami Shores Village. , • Remarks (Signed) s. _. �2 �� .. 1 r7; ✓' !� STATE OF FLORIDA, COUNTY OF DADE. ss. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared and who, being by me first duly sworn, upon oath deposes and says that he is the. of the above described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts therein by him stated are true.. Permit No.._.._& . - Disapproved (Signed) Read, Sworn to and Subscribed before me. Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE `• - or changes to this application after approval to me well !mown, Date has been obtained from when such re- inspection is made necessary by improper notice for inspection or faulty 'Date PERMIT APPLICATION FOR MUNICIPALITIES OF DADE COUNTY (OWNER TO RETAIN COPY) //2 /1/E 9 7 -% Sree / Job Address Legal Description r i / Lessee / Tenant Owner's Address Contracting Co. Qualifier State# Architect /Engineer Bonding Company Mortgagor 1(1 m9 7 Y AR/ Cfaoann e / 0Puis l / 42 ,/VE '97 , fire e Signature of Owner and /or Condo President Date: Notary as to Owner and /or Condo President My Commission Expires: * * PERMIT FEE: APPROVED: Mechanical Fire Plumbing Address SS# - - Phone Competency# Ins. Co. Address Address Address Tax Folio #',z ? j /1 N7s " Master Permit #_1/670 O Phone 25g - d i e/0 Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL PAVING FENCE SIGN WORK DESCRIPTION Lep/we e -3 ra a7,5 G}'� i �'/ , Y�Y�i 1"S Square Ft. Estimated Cost#/' l WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT). Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING, and MECHANICAL work. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do - he work stated. Q S _natu of Contra ate: oning Building ,ly 7 / 5 0)) t o Owner - Builder N ary as to Co tractor or 0 ner- Builder My Commission Expires * * 1t th * * Other Electrical Engineering Y9u have, this date, made application for a building permit as an owner - builder. You should be advised of the following provisions and requirements that apply to owner - builder. Proof of Ownership - Prior to a building permit being issued to you, you must submit proof of ownership of the land concerned in the application in the form of a recorded deed, showing you own the property, or a copy of mortgage or warranty deed of the land, or a Dade County tax receipt, statement to contain legal description of property and indicate property is in your name. Legal description and name on document of proof must correspond to the name and legal description on the application. Responsibility - You will be responsible for all work done by your day labor employees, and you must either employ licensed contractors or persons to be paid on an hourly or per diem basis. Any one contracting (including labor) with you, verbally or in writing, on a fixed fee basis for any work, who is not properly licensed, will be subject to a fine of $500.00 and /or imprisonment for six months. Insurance - You should be advised that if your day labor employees cause any damage to persons or property, or if any of your day labor employees are injured on the job, you are liable. Your regular home insurance policy ordinarily does not cover this type of liability. Withholding Taxes, etc. - You should be advised to investigate your responsibility for withholding Social Security, Federal and State Unemployment Insurance Taxes and Federal Income Taxes from the wages of employees working for you on the proposed construction, and for making returns thereof to the proper agencies. Work Permitted Owner - Builder - An owner - builder subject to the foregoing provisions and requirements, is limited to constructing one single family residence each year for his own use and occupancy; ;or maintaining, altering or repairing his own single family residence. If you do not intend to do the work involved yourself, or with day labor, please list below, the name of the individual or firm with whom you have entered (or will enter) into a contract for the work. NOTICE: SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMING, ROOFING AND MECHANICAL WORK 3 4-zeto o Name of Individual or Firm I, the owner of property described as that I have read the foregoing instructions, and am aware of my responsibilities and liabilities under my application for a building permit for construction work on the above described property. Witness MIAMI SHORES`VILLAGE BUILDING AND ZONING DEPARTMENT INSTRUCTIONS TO OWNER- BUILDER / 4;2a2 14F 97 �� ✓��% Address do hereby certified BUILDING ELECTRICAL PLUMBING ROOFING MIAMI SHORES VILLAGE, FLORIDA ° DATE - - 19 ° PERMIT N9 6270 Contractor's i' License No. ❑ Work to be performed under this Peranit_ _ Owner of Building Architect Contractor or Builder Legal Lot Description II Bl. CONTRACTOR OR BUILDER Subdi- vision Address of Value of 11 Amount of � f,. Building Project $ II Permit $ This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon- sibility for work done by his agents, servants or employees. Signed: ., r ' ` i f INSPECTOR In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with allf8nces and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In as cepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. 0 BY AUTHORITY BUILDING ❑ MIAMI SHORES VILLAGE, FLORIDA ELECTRICAL ❑ PLUMBING ❑ PERMIT N? 9237 Contractor's License No. ROOFING NI Owner of Building Work to be performed under this Permit Architect Contractor or Builder r' Legal Lox Y Description 1 Bi Address of Building Subdi- vision Sq Ft Value of 11 Amount of Project $ 11 Permit $ Date —_ . 19�' This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica- tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance kith an plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoke] at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon sibility for work done by his agents, servants or employees. Signed• r (INSPECTOR) BY In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulation- pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee. CONTRACTOR or BUILDER BY AUTHORITY G. C. PERMIT # 6195 Application is hereby made for the approval of the detailed statement of the plans and specifications herewith submitted for the build- ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved plans and specifications must be kept at building during progress of the work. Owner's Name and Address.. COEI N ®A G E R , Q CJ C • Registered Architect and /or Engineer Name and address of licensed contractor Location and legal description of lot to be built on: Lot Block Subdivision 1122 N. E. 97Tti ST. [AI AM E SNORES FLA. Street and Number where work is to be done State work to be done and purpose of building (by floors) ROOF I NG ° HILL RS 1 D E N C E ADD I T I ON APPLY 1" INSULATION,. 30/90 & W,C TILE & 1/3 & 2/15 ASP. FELTS & GRAVEL New Building X Remodeling Addition X To be constructed of Kind of foundation Estimated Total cost of improvements $ Zone cubage required Distance to next nearest building Maximum live load to be borne by each floor I hereby submit all the plans and specifications for said building. All notices with reference to the building ' its construction may be sent to P 0, Box 565, TAM IAMI STATIO MI AMI 1 FLORIDA 331 `^! The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer of labor under the Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement, and has complied with the provisions thereof, and will require similar compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit; and will post or cause to be posted for inspection on the site of the work such ublic notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors, on work to be erforme nder this permit, as are licensed by Miami Shores Village. FF, N 1 NDU S L. Remarks (Signed) STATE OF FLORIDA, COUNTY OF DADE. and who, bein g of the above therein by him Permit No Disapproved (Signed) ss. MIAMI SHORES VILLAGE BUILDING INSPECTION DEPARTMENT APPLICATION FOR BUILDING PERMIT GIFFEN INDUSTRIES, INC. Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap- peared by me first duly sworn, upon oath deposes and says that he is the. described construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts stated are true. O Date Building Inspector I vy Council Approved Date Disapproved Date 3 ®3 ,19 6 5 No 50 Street....E.• i L_... E... HIALEAII P. 0. Box 565, TAr-7 I At.1 1 ST A. L'-9 I AN I , FLA. 331 Amount of Permit $ plan Cubage Size of Building Lot Repairs No. of Stories 0 C1 E Roof Covering 5_ LDO • R. N +RTHRUP, Read, Sworn to and Subscribed before me. NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval the Planning Board. A re- inspection fee of 51.00 will be charged when such re- inspection is made necessary by improper notice materials and /or workmanship. and for no other purpose. 6.1). & TOLE V ( boo s/r ) Ro ©G 0 ne to me well known, Notary Public, State of Florida My Commission Expires PLANNING BOARD DATE Chairman Member Member Member Member ...... Member Date has been obtained from for inspection or faulty SITE SPECIFIC INFORMATION Owner's Name: g74 1 Permit # Job Address' 1122- M q7 ST• 1•4)A 1•A t .tIDP- ss,Fl. Roofing Contractor 140 ¢ T`v g Oo*r f ►�[ tD Type of Tile' t1 -T\07. _ FOA<a4 SET Date Installed' 7 •2 1 • op Approximate Roof Height: 12 feet Type of Access to Roof: Scaffolds ` Ladder Other Approximate Square Footage of Roof: 4200 ft2 Required Testing Force: 35 Ibs, Testing Equipment: Chatillion 100 Date Tested: 7 7 - c - • 0 ° • IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS REPORT S MITTED BY: Civil Engineer: Lab Certification 1 98 -0608.04 State of FL Certificate Authorization a 4100 U.S. SOUTH Engineering & Testing Lab., Inc. 6065 N.W. 167th Street, Suite B -23 • Miami, Florida 33015 Telephone: (305) 558 -2588 • Fax:. (305) 362 -4669 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 P.E. TEST RESULTS P = PASS, F = FAIL c1. :7 A 95 7/04' 5 4 64o3 Project N°_ 000116 3 12— Roof Pitch' Test Location Uplift Pull Test (P or F) Test Location Uplift Pull Test (P or F) Test Location Up l f t o� F Test Location Test (P or F) 1 t7p.,L�tr D 26 #,G47 51 p> slc t7 76 2 27 FA 52 77 3 28 53 78 4 29 54 79 5 30 55 80 6 3 56 81 7 32 57 . • 87 8 33 58 R3 9 34 59 84 10 35 60 85 11 36 61 86 37 62 R7 12 13 38 63 88 14 39 64 89 15 40 65 90 16 41 66 91 17 42 67 92 18 43 68 93 19 44 69 94 20 45 70 95 21 46 71 96 22 47 72 97 23 48 73 98 24 49 74 99 25 50 75 100 SITE SPECIFIC INFORMATION Owner's Name: g74 1 Permit # Job Address' 1122- M q7 ST• 1•4)A 1•A t .tIDP- ss,Fl. Roofing Contractor 140 ¢ T`v g Oo*r f ►�[ tD Type of Tile' t1 -T\07. _ FOA<a4 SET Date Installed' 7 •2 1 • op Approximate Roof Height: 12 feet Type of Access to Roof: Scaffolds ` Ladder Other Approximate Square Footage of Roof: 4200 ft2 Required Testing Force: 35 Ibs, Testing Equipment: Chatillion 100 Date Tested: 7 7 - c - • 0 ° • IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS REPORT S MITTED BY: Civil Engineer: Lab Certification 1 98 -0608.04 State of FL Certificate Authorization a 4100 U.S. SOUTH Engineering & Testing Lab., Inc. 6065 N.W. 167th Street, Suite B -23 • Miami, Florida 33015 Telephone: (305) 558 -2588 • Fax:. (305) 362 -4669 ON -SITE CONCENTRATED UPLIFT LOAD TESTING OF ROOF TILE IN FULL ACCORDANCE WITH METRO -DADE BUILDING CODE COMPLIANCE PROTOCOL PA 106 P.E. TEST RESULTS P = PASS, F = FAIL c1. :7 A 95 7/04' 5 4 64o3 Project N°_ 000116 3 12— Roof Pitch' SKETCH OF ROOF C9 iT1 ti ■ ® l� i +1° 0 4P 4. NOTES: jog L 1 22. g r• 11 7• H Nit IAM l 414SkG.S ,c • SHEET NO. CONTRACTOR CHECKED BY DATE SCALE 'Z 0F 2. PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date 3 / b q Job Address i 1 f ' 7 5'( Tax Folio Legal Description Historically Designated: Yes No Owner/Lessee / Tenant 12 Owner's Address 112 E- 1 7 Contractin Co. � k[ 5 c o `r% ct 1 7' Qualifier r# Au n5 ss# ?),_,/ Phone State # CC o 5 G _l '' Municipal # � Architect/Engineer G wt Address Bonding Company 9v 1 A Address Mortgagor t Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANIC ROOFIN - PAVING FENCE SIGN WORK DESCRIPTION ( :4 fVi Lion qqu arc/ "Rol ?c 64 1-( I(1n / as4 (C.010C -11A0 4,-;" Square Ft. Li 10 0 WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable i ll" laws regulating construction and zoning. Furthermore, I authorize the above-named ct. t • o w • stated. �'Aw�; 000 t om., aims Signature�� • - Signature Notary as to My Commission Expires: FEES: PERMIT - td -q 5 fP Date Comm My Bonded �20Q0 • er an r RADON APPROVED: Zoning Building Mechanical Competency # Ins. Co. ( f`00 Y Ck k 15 5.)Q Uf Date Master Permit # 6 y® 3 , r Phone 3 C7 3- 7 5 1 ( - L('- 7 Address a t 70 Oca Cog lJ d Estimated Cost (value) Date Notary as t Contractor or Owner - Builder Date My Commission Expires: C.C.F. / NOTARY ° 0— ,fc 4/4 Electrical tq,6Qo. • BOND -3 TOTAL DUE Plumbing Engineering N P.4ft A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO. STATE OF FLORIDA: COUNTY OF DADE: THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance min Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1. Legal description of property and street address: I 0? 9 7 5i Pt( a,n,,; L �(no6e5 / ' l 33 i 3 8 • 2. Description of improvement: Roofing 3. Owner(s) name and address: (.e +er To3 5 r (l as /3 E., 97 5'( Interest in property: Owner Name and address of lee simple titleholder: 4. Contractor's name and address: 5. Surery:(Payment bond required by owner from contractor,if any) Name and address: N/A Amount of bond $ 6. Lender's name and address: N /A 7. Persons within the Stale of Florida designated by Omar oy Section 713.13(1)(a)7., Florida Statutes, Name ano address: N/A Print Owners Name Sworn to anc suoscr ;oeo Notary Public CZ- Print Notary's Name � S ' 1Z Dec My Commission Expires: NOTICE OF COMMENCEMENT mi amt Sk) -s t F ( 33 Roberts Roofing & Supply Inc. 2170 Opa-Locka Blvd. Opa- Locka, F1 33054 •E3Y CERTIFY original th hatch• +' ^F CO`' WITNESS my hand A. COUNT OF DADE e �T- s OOR 123780 2000 IIAR 15 13 :57 , .c� or other documents may be served a; pro 8. In addition to himsell. Owner designates the following person(s) to receive a copy of the Lienor's Notice as provioed +r: Section 713.13(1)(b), Florida Statutes. Name and address: N/A 9. Expiration date oI this Notice of Commencement: (the expiration dale is 1 year from the date of recording unless a different date is specified) Prepared by Robert Acosta Address: 7 0 Opa-Locka B l vci Opa- Loacka, F'1 3305; Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROBERTS ROOFING & SUPPLY nn �� Contractor's Name: Job Address: E- 9 7 5 f INC. ❑ (Low Slope Application) ROOF CATEGORY ❑ (Nail -On Tile) ❑ (Asphalt/Fiberglass Shingles) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof E7 Re- roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft') Sloped Roof Area (ft Li 700 Total (ft L(7b6 Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7 -88 table 1): 'IC ,(Mortar- Adhesive Set Tile) Ft. n v Ft. A V Deck type:1 "x6" T & G WOOD ATTACHMENT Fastener Type: 1 +" RING SHANK NAIL , SPACING 12" Field: Perimeter: 6" Corner: 6 DETAIL 1 & 2 ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) S 11 ROOF PLAN 129.01.78 1I6 Page -1 a Ridge Ventilation? NIA MEAN HEIGHT Deck type: 1 Underlayn►ent: 3- Insulation: 12" ROOF SLOPE D E T A I L 3 Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. 'x6" T &G WOOD SLOPED SYSTEM DESCRIPTION #30 FELT TYPE II ASTM D 226 N/A Fastener type & spadng: Cap Sheet: 11" RING SHANK NAI: 12" FIELD S 6" LAPS HOT MOP #90 ASTM D312 TYPE III OR IV Roof Covering: Page -2 . ivlavke r Lavi0vo d Drip edge: 1011 2ix2i EAVE DRIP .26 GA. GALV. ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance -Cover Sheet a) Specific System Description b) Specific System Limitation c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals (Pmaxl:`Z - 6 x ( Aerodynamic ( Pmax2: 1(0 (o x X X ( Aerodynamic (Pmax3: 9(o "J X X (Aerodynamic TILE CALCULATIONS Multiplier): "0 ) - M = M 783 PCA: ,, 1p / Multiplier): , r ) - m 5-, 57= M ?.0 PCA: Multiplier): '0 ) M C• `= M PCA: G 1 APPENDIX "F" : • REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS As it pertains to Ado this Appendix "F°, it.is the responsibility of the roofing contractor to provide the owner with tt required roofing permit, to provide the owner with this appendix and to exAIain to the owner the content !aim. The provisions 'of Chapter 34 of the South Florida Building Code (SFBC)' govern al fl requirements and standards of the Industry for roofing system install lions, of this should be addressed as part of the agreement between the owner and t� b I the minimum r; items adjacent box indicates that the item has been explained, to contractor; . .The the oivttcr's initnit following initial in the =- —I;': Aesthetics- Workmanship: The workmanship previsions revi ' one of Chapter 34 are Ibr the purpose of providing that the' roofing system meets the wind resistoffee 'and water intrusion performance ; Aesthetics (appearance) issues are not a consideration with respect to workmanship shell as color or architectural'appearattee, that are not' part of be addressed as part of the a zoning code, should provisions. Aesthetic issues ld standard e . contractor. agreement between the owner and the cont : Rearming Wood Decks: When replacipg roofing, he existing in accordance with the current provisions of Chapter 29 of the••S wood roof deck may have to be r o r t o removing the existing roof system) , FBC • (The roof deck Is usually concealed prior to Common Roofs: Common roofs are those which units (i.e. townhouses, condominiums, etc.). In buildingswith common roofs, the between cent neon and/or. owner should notify the occupants of adjacent u n i ts of roofing work to be performed. • the roofing cont ractor and /or • Exposed ceilings: Exposed, open beam ceilings are where the underside • viewed from below. "The owner may wish to maintain the •arc1titectural appearance, th therefore, roofing nail roof decking penetrations of the underside of the decking may not be acceptable. The SFBC provides b can b� this appearance: P s the option of maintlinin� ies• f onding Water: The current roofs . cause water to pond (accumulate) in low -lying 'areas theroof, dbgl n an indication distress and may require the . review of a profess'ioncl structural en tneer. b may not drain ��•cll and nr;,�• xpr an ond'perf • e . the new roofing system. ay h a structural roofing syste is removed. Ponding condition should be co Ponding m not'be evlden unc lie or • / 6. Overflow Scuppers (wall outic overloaded from a build u of water, �)' It Is required that rainwater flow o so dint the roof is no P Perimeter /edge walls or other roof extensions may block this e if discharge to install overflow scuppers in with Chapter 23 of the SFBC. overflow scuppers (well outlets) are not provided. It may be n ` PP accordance Ventilation: Most roof structures should have some.ability to vent natural airflow through of the structural assembly( the building itself). The existing amount of attic ventilation troublt tits interior may be beneficial to consider additional venting•whiclt can result in extending l i not be reduced. It • � tltc service life of the roof. The owner may contact the Mianti•Dadc tnformation'regarding thc•above. County Consumer Scn •ices Department for further 3 -1 0- ® d traces/Agent's Signature Date • '!!' i+?« i'! d1ir Kl '; +��11' +�y4'rVi67;f�!,".aN�a ' "" .. • ��'• — ';:1 .:.•:: . 't Contractor's Signature mE7P00 PRODUCT CONTROL NOTICE OF ACCEPTANCE Monier Lifetile LLC 135 NW 20 St. Boca Raton, Florida 33431 Your application for product Approval of Monier Lifetile LLC Villa, Capri, & Roll Tiles under Chapter 8 of the Miami -Dade County Code governing the use of Alternate Materials and Types of Construction, and completely describ:d in the plans, specifications and calculations as submitted by: Redland Technologies, The Center for Applied Engineering, Inc., and Professional Service Industries has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -14 and the standard conditions on page 15. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compl iance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 97- 1124.16 EXPIRES: 06/25/01 THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. APPROVED: 06/25/98 1 Miami -Dade County Internet mail address: ppstmaserebuildIngeodeonhine .com i00 Vldd11S ,LSV00 .LSV3 Revises: 95- 0322.07 95- 0322.03 95- 0316.04 METROPOLITAN DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO - DADE FLAGLER BUILDING 140 WEST FLAGLER STREET. SUITE 1603 MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 PRODUCT CONTROL DIVISION (305) 375 -2902 FAX (305) 372 -6339 aul Rodriguez Product Control Supervisor Homspage: Z696 C99 SOC YVd 8090 a3tf 96.50.80 Z0012I MONLER LIFETILE LLC Product Control No.: 97- 1124.16 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Product Dimensional Monier Lifetile I = 16'h" LLC Villa & Roll w = 13" thick Monier Lifeitile LLC Capri Tile Trim Pieces Product Rainproof II Ice and Water Shield L= 17" W= 12 ,4" %3" thick I = varies w = varies varying thickness TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Dimensions Specifications - 30"x75' roll 36 "x or 60" x 75' roll 36 "x75'roll Test Specifications PA 112 PA 112 PA 112 Page 2 of IS iddi1S JSV00 ,LSV3 Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Low profile, interlocking, high pressure extruded concrete roof tile equipped with one nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. Product Description Manufacturer PA 104 Single ply; nail -on Protect -O -Wrap, underlayment with Inc. 2" self - adhering top (with current NOA) edge. PA 103 Self- adhering W.R. Grace Co. underlayment (with current NOA) Frank Zuloaga, RRC Roofing Product Control Examiner Z898 C99 20C rid 9C:90 «3M 86/90/90 C 00121 MONLER i,.:Lc Tile Nails Tile Screws Roof Tile Adhesive ( "Polypro® AH 160 ") Product Dimensions Wood Battens Vertical Min. I "x 4" Horizontal Min. 1 "x 4" for use with vertical battens or Min. 1"x 2" for use alone Roof Tile Mortar ( "TileTiteTM ") Roof Tile Mortar ( "Quikrete® Roof Tile Mortar #1140") Roof Tile Mortar ( "BONSAL® Roof Tile Mortar Mix ") Hurricane Clip & Fasteners Min. 8d x 2 %2" or min. l0dx 3" #8x 2 '' /2" long 0.335" head dia. 0.131" shank dia. 0. 175" screw thread dia. N/A N/A N/A N/A Clips Min.' h" width Min. 0.060" thick Clip Fasteners Min. 8d x 1 '/4" Test Specifications Wood Preservers Institute LP — 2 PA 114 Appendix E PA 114 Appendix E PA 123 PA 123 PA 123 See PCA Page 3 of T5 A'IddfS ,LSVOD ,LSd3 Product Control No.: 97-1124.16 Product Description Salt pressure treated or decay resistant lumber vattens Corrosion resistan screw or smooth shank nails Corrosion resistant, coated, square drive, galvanized, coarse thread wood screws Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Prepared mortar mix designed for mortar set roof tile applications. Two component polyurethane adhesive designed for adhesive set roof tile applications. Manufacturer generic generic generic Bermuda Roof Company, Inc. with current PCA Quikrete Construction Products with Current PCA W. R. Bonsai Co. with current PCA Polyfoam Products, Inc. PCA #94-0401.01 i ?A 114 Appendix E Corrosion resistant Generic clips with corrosion resistant nails. aga, Roofing Product Control Examiner Z698 C99 SOC %V3 6C :90 aaM 96/SO/90 1>00173 MONIER LIFETII.E LLC Test A, envy Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. EVIDENCE SUBNIITrED Test Identifier Test Name/Report Date 7161 -03 Appendix III '7161 -03 Appendix III 94-084 94 -060B 25- 7094 -1 25- 7094 -7 25.7094 -4 25- 7183 -1 25-7183-2 Page 4 of 15 .1ddl1S ,LSVO3 ,LSV3 Product Control No.: 97- 1124.16 Static Uplift Testing Dec. 1991 PA 102 Static Uplift Testing Dec. 1991 PA 102(A) Static Uplift Testing May 1994 PA 101 (Mortar Set) Static Uplift Testing PA 101 (Adhesive Set) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, New Construction) Static Uplift Testing PA 102 (4" Headlap, Nails, Battens) Static Uplift Testing PA 102 (4" Headlap, Nails, Direct Deck, Recover/Reroof) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing PA 102 (2 Quik -Drive Screws, Battens) March, 1994 Oct. 1994 Oct. 1994 Oct. 1994 Feb. 1995 Feb. 1995 uloaga, RRC Roofing Product Control Examiner Z898 C99 SOC XVd Ot :90 aa&t 96/S0/90 SOO1 MONIER LIFETII.E LLC Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Red land Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Professional Service Industries, Inc. Ipt identifier Test Name/Report Date 25- 7214 -2 25 -7214-6 7161 -03 Aopendix I1 Letter Dated Aug. 1, 1994 P0631.01 PO402 Project. No. 307025 Test #MDC -76 224 -47099 Page 5 of 15 iddnS ,LSV00 ,LSV3 Product Control No.: 97- 1124.16 Static Uplift Testing PA 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing . PA 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Nail -On) Wind Tunnel Testing PA 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Wind Driven Rain Oct. 1994 PA 100 Physical Properties Sept. 1994 PA 112 :��4111r — mega , . Roofing Product Control Examiner 2698 C91 90C %V3 Or:90 (MA 98 /S0 /90 ,00Z MONLER LIFETIME LLC Deck Type: Deck Description: SYSTEM A: Slope Range: Underlayment: Vertical Battens: Horizontal Battens: In S Roofing Tile: Comments: SYSTEMS Wood, Non- insulated New Construction 19/32" or greater plywood or wood plank. Counter- Batten Application 2 " :12" to 7 " :12" Note: Counter- Battens, as noted below, are required for slope range 2 " :12" to less than 4 ":12" and are optional for slopes of 4 " :12" to 7 " :12 ". For slopes exceeding 7 " :12 ", refer to System C. Install underlayment system in compliance with Dade County Application Standard PA 113. Install vertical battens in compliance with Dade County Application Standard PA 118 stall horizontal battens in compliance with Dade County Application tandard PA 118. Install tile in compliance with Dade County Application Standard PA 118. (See "Data for A.tachment Calculations" included in this Approval.) I. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page 6 of 15 nuns isvoO ,LSV3 Product Control No.: 97- 1124.16 n uloaga, RRC Roofing Product Control Examiner 2696 C99 20C %d3 t : 90 Q3M 96/20/90 0 qj MONIER LIFETILE LLC SYSTEMS (CONTINUED) Deck Type: Wood, Non - insulated Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM B: Direct Deck Application Slope Range: 4 ":12" to 7 ":12" Note: System B is only acceptable in this slope range. For slopes less than 4 ":12 ", refer to System A. For slopes in excess of 7 ":12 ", refer to System C. Underlayment: Roofing Tile: Comments: Product Control No.: 97- 1124,16 Install underlayment system in compliance with Dade County Application Standard PA 118. Install tile in compliance with Dade County Application Standard PA 118. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15/32 " plywood is an acceptable substrate. Page 7 of 15 duns ISVOO ISV3 uloaga, RRC Roofing Product Control Examiner Z898 C99 COC YV4 Tb:9n (13M 9RicniQn • 8 MONIER LIFETILE LLC Deck Type: Deck Description: SYSTEM C: Slope Range: Underlayment: Horizontal Battens: Roofing Tile: Comments: Wood, Non - insulated SYSTEMS (CONTINUED) Product Control No.: 97- 1124.16 New construction 19 /32" or greater plywood or wood plank. Horizontal Batten Application 4 ":12" or greater Note: Horizontal battens, as noted below, are required for slopes in excess of 7 ":12" and are optional for slopes of 4 ":12" to 7":12". For slopes less than 4 ":12 ", refer to System A. Install underlayment system in compliance with Dade County Application Standard PA 11 Install horizontal battens in compliance with Dade County Application Standard PA 119. Install tile in compliance with Dade County Application Standard PA 119. (See "Data for Attachment Calculations" included in this Approval.) 1. For re-roof applications, 15 /32" plywood is an acceptable substrate. Page 8 of 15 azdanS JSVOO ,LSV3 Frank Zuloaga, RRC Roofing Prbduct Control Exam inr Z698 C99 20C %V3 9p :90 aaa 96/20/90 60 MONIER LIFETILE LLC Product Control No.: 97- 1I24.16 SYSTEMS (CONTINUED) Deck Type: Wood, Non- in; Deck Description: New construction 19 /32" or greater plywood or wood plank. SYSTEM D: Mortar or Adhesive Set Application Slope Range: 2 " :12" to 7":12" Note: System D is only acceptable in this slope range. For slopes in excess of 7 " :12 ", refer to System C. Uriderlayment: Roofing Tile: Comments: Install underlavment system in compliance with Dade County Application Standard PA 120. (See System Limitation #S.) Install tile in compliance with Dade County Application Standard PA 120. (See "Data for Attachment Calculations" included in this Approval.) 1. For re -roof applications, 15 /32" plywood is an acceptable substrate. Page 9 of 15 R'IddIlS i.SVOD ,LSV3 Zuloaga, RRC Roofing Product Control Examiner Z696 C99 20C BY3 9P:90 Q3A1 96/90/90 nTnr i MONIER LIFETIME LLC Product Control No.: 97- 1124.16 :SYSTEM LIMITATIONS 1. The standard minimum roof pitch for Monier Lifetile LLC Villa, Monier Lifetile LLC Capri & Monier Lifetile LLC Roll, low profile tile shall comply with Dade County Application Standards PA 118, PA 119 or PA 120, depending on the method of installation. 2. For nail-on applications, fasteners for mechanical attachment of tiles shall have a head diameter larger than that of the preformed hales in the tile. 3. System installation shall be in compliance with the system specifications outlined in this Product Control Approval. The method of attachment utilized shall provide sufficient attachment resistance to meet or exceed the required resistance determined in compliance with Dade County Protocol PA 115 or PA 127. Tile profiles listed here in have been tested for both wind characteristics and static uplift performance, therefore, attac.:unent calculations for installation in compliance with PA 115 or PA I27 shall be done as a 'Moment Based System'. 4. For adhesive set tile applications, a. field static uplift test by a Dade County accredited testing agency, in compliance with Dade County Protocol PA 106, shall be performed. 5. For tile applications, 30/90 hot mopped underlayment applications may be installed perpendicular to the roof pitch unless stated otherwise by the underlayment material manufacturer's published literature. 6 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo for identification in the field. 7. Applications for roofing permits shall include a completed Section 1I of the Uniform Building Permit, a copy of manufacturer's cu,Tent specifications and details, a copy of this Product Control Approval and a copy of the Product Control Approval of any Roofing Component used in the proposed tile application. Reference shall be made to appropriate data for the required fire rating. 8. The applicant shall retain the services of a Dade County certified testing laboratory to maintain quality control in compliance with the South Florida Building Code and related protocols. Samples taken shall be in compliance with Dade County Protocol PA 112, Appendix 'A'. 9. Fire classification is not part of this aceptance. Page 10 of 15 AldanS LSVO3 ISV3 Frank Zuloaga, RRC Roofing Product Control Examiner Z696 C99 SOC %Vd L0 :90 OA 96/SO/90 MONIER LIFETILE LLC Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Profile Monier Lifetile LLC Villa, Roll, and Capri Batten s 5.57 Table 2: Restorin 3 Battens Tile Application Table 1: Aerodynamic Multipliers - (ft') Direct Batten Deck s 6.30 5.48 4 ": Approved Nails 1 nail 2 nails 4.10 7.10 DATA FOR ATTACHMENT CALCULATIONS X'IddnS ZSV01 .Lfid'i X ( ft') Batten Application 0.27 1 screw 22.90 Page 11 of IS Approved Screws 2 screws 49.10 1 nail 24.20 Product Control No.: 97- 1124.16 7l (ft') Direct Deck Application 0.29 g Moments due to Gravity - M, (ft -Ibf) 12" 5 " :12" Direct Deck Batten s 6.18 5.37 Batten s 5.24 Direct Deck 6.05 6 ":12" Direct Deck 5.90 Batten 7 ":12" or greater Di s Deck 5.09 N/A Table 3: Attachment R ;istance Expressed as a Moment - Mr (ft-Ibf) for Nail -On Systems Approved Field Clip With: 2 nails 34.80 Approved Eave Clip With: 1 nail 22.10 Direct Deck 11.80 21.90 25.80 47.10 24.30 35.50 19.00 31.90 1 Data noted in Table 3 is for installation with a 3" tile headlap. 2 Approved screws are as noted in the 'Trade Names of Products Manufactured By Others' and 'Profile Drawings' sections of thin Approval. Clips on eave the are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. uloaga, RRC Roofing Product Control MCA m;nor 7.RAR £AR sac. Tva Lb :Rn 070 2 nails 32.20 OR/CA/OA • 'Tr rm MONIER LIFETILE LLC DATA FOR ATTACHMENT CALCULATIONS (CONTINUED) Table 3-A: Attachment Resistance Expressed as a Moment - M, (ft-lbf) for Nail -On Systems Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Profile Monier Lifetile LLC Villa Tile, Roll Tile, and Capri Tile Tile Application Direct Deck New Construction (min. 9 / 32 " plywood) Direct Deck Recover /Reroof (min. 15 / plywood) Battens New Construction I Tile installation with a .4" headlap using two (2) Approved 10d x 3" long polymer coated, corrosion resistant, ring shank nails installed in manufactured holes located 2W from the head of the tile. Clips on eave tile are not required for this attachment configuration unless the Required Moment of Resistance exceeds the values noted above. Table 4: Attachment Resistance Expressed as a Moment _ M, (ft-Ibf) for Mortar or Adhesive Set Systems 1 Tile Application Mortar Set Adhesive Set Page 12of15 YTAAnC Tcvnl TSVq Product Control No.: 92 Two (2) 10d x 3" Tong nails 67.50 43.00 50.90 Attachment Resistance 20.60 86.61 �! uloaga, RRC Roofing Product Cem mt 7898 4'9Q gnr TVA Rh :Qn a34 QR/gn/Qn MONIER LIFETELE LLC PROFILE DRAWINGS MONI;R LIFETILE LLC VILLA TILE Mornit LtFETU.E LLC RoLi TILE Page 13 of 15 Product Control No.: 97- 1124.16 0.34" MONIER LIFET]LE LLC MO— 0.07" 0 . 16 ' 1 0.12 PROFILE DRAWINGS (CONTINUED) MONIER LIFETILE LLC CAPRI 2.45' za OCC. Page 14 of 15 1.71' 0.131" APPROVED SCREW FOR SCREW DATA IN TABLE 3 Product Control No.: 97- 1124.16 1 $00SitPo 0.170•• 1 Page 15 of 15 MONIER LIFETtLE LLC Product Control No.: 97- 1124.16 Monier Lifetile LLC ACCEPTANCE NO: 97- 1124.16 135 N.W. 20 St. APPROVED : June 25, 1998 Boca Raton, FL. 33431 EXPIRES : June 2S, 2001 NOTICE OF ACCEPTANCE STANDARD CONDITIONS 1 Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently Iabe;ed with the manufacturer's name, city, state, and the following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Buildin,; Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no Longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of : Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed irr advertising literature. If any portion of the Notice of Acceptance is displayed, then it shah be done in :ts entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 15. END OF THIS ACCEPTANCE o ...C..... n, -J.... ^ -_. -.I r CJ V '. - aan 954 4eZ 1 . -98 03:14P Polyfoam products PRODUCT CONTROL NOT O F ACCEPTANCE Polyfoam Products, Inc. 2400 Spring - Stuebner Road Spring, TX. 77383 Your application for Product Approval of: Yoly oani,/rotlycts "Polvnro A i " Roof file At ive under Chapter B of the Miami-Dade County Codc governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Tho Confer for Applied Engineering, Inc. and Mlles Laboratories Polymers Division has been recommended for acceptance by the Building Codc Compliance Office to be used in Dada County, Florida under the specific conditions set forth on pages 2-14 and the standard conditions on page 15. This approval shall nut be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to sectuc this product or material at any time from a jobsitc or manufacturers plant for quality control testing. If this product or material falls to perform in the approved manner, the building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Codc Compliance Office reserves the right to revoke this approval, iFit is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Codc. Thc expense of' such testing will be incurred by the manufacturer. ACCEPTANCE: NO.: 98 - 0303.02 Renews: 96- Q402,02 EXPIRES: 04/16/01 THIS IS THE COVERSHEET,_SEE ADDITIONAL, PAGES FOR SPEC IC N GEN RAL. CONDITIONS Dj7ILpINCt COgE COMMITTFA . This application for Product Approval has been reviewed by the Miami -Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in Dade County, Florida under the conditions set forth above. APPROVED: 04 {16/98 Inc. 954 475 -1462 P.02 METROPOLITAN DADE COUNTY. FLORIDA METRO•DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE METRO•DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1653 (305) 375.2901 FAX (305) 315.2908 PRODUCT CONTROL DIVISION (305) 375-2902 FAX (305) 372 -6339 uI Rodriguez Product Control Supervisor Charles Danger, P.E. Director Building Code Compliance Dept. Miami•Oade County 05/19;98 TLTE 14:27 FAX 305 863 9692 May -19 -98 03:14P Polyfaam POLYFOAM PRODUCTS, INC. Applicant: Polyfoam Products, Inc. 2400 Spring - Stuebner Road Spring, Texas 77383 -1132 Category; Sub - Category: TyOSj Sub -Type: EAST COAST SUPPLY tea-. :.ice 1.4x Products Inc. 954 475 -1462 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING COMPONENT APPROVAL Roofing Component Fastening/Adhesive Roof Tile Adhesive Two Component Polyurethane Contact: Pat Murray P.O. Box 1132 Spring, Texas 77383 -1132 Phone: (713)350.8888 Fax: (713)2R8.6450 Product Control No.: 98.0303 ,02 Product Control No,: 28- 0303,02 Approval Date: 6nril 16. 2998 Expiration Date: April 16. 2001 System Description Polyfoam Products, Inc., produces two-componcnt expanding polyurethane adhesive for the attachment of clay and concrete roof tile. Polypro® AI•I160 is specially designed for application of concrete and clay roof tile over a variety of roof deck substrates and underlayment materials. Polypro® adhesive is applied with proprietary Foampro® RTFI000 dispensing equipment. Approval of this product is specific to the two component mix and Foampro® RTF1000 dispensing equipment. Alternative methods of dispensing will require a revision to this approval. Polypro® adhesive shall be applied only by 'Qualified Applicators', licensed by Polyfoam Products, Inc. Certificates and idimntification cards are issued to applicators upon successful completion of a application training program. Approval of this adhesivc system is contingent upon application by a 'Qualified Applicator. Z003 P. 03 POLYFOAM PRODUCTS, INC. Product Control No.: 28- 0303.0% TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Product Product Dimensions . .Specl lcatikna Descriptor eolyproe AH160 N/A PA 101 Two component polyurethane Lam proe RTh 1000 N/A See Detail Attached Dispensing Equipment Page 3 of 15 Prank Zuloaga, RRC Roofing Product Control Examiner May- 19 -913 03 :14P Polyfoam.Products Inc. POLYFOAM PRODUCTS, TNC. TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Product Test Criteria Product Description Manufacturer PA 120 All Dade County Component Approved MI Dade products as detailed in Dade County County Application Standard PA 120 Approved Products Underlayment Roof Tile PA 101 All Approved roof tile systems having All Dade tested in compliance with Dade County County Protocol PA 101, as detailed in the systems Approved section of this Component Approval Products 954 4 75 1462 Page 4 of 15 954 475 -1462 P.05 Product Control No.: 98- 0303,02 - May - 19-98 03:14P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Control No,; 98- 0303.02 Test Agency Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Southwest Research Institute Trinity Engineering TEST REPORTS 954 475 -1462 P.06 Test Identifier Test Name/Report age #94.060 Miami Dade Protocol 04/08/94 PA 101 257818 - I PA Miami Dadc Protocol 12/16/96 PA 101 25. 7438.3 SSTD 11 -93 10/25/95 25- 7438.4 SSTD 11-93 10/25/95 25- 7438 -7 SSTD 11 -93 11/02/95 25 -7492 SSTD 11 -93 12/12/95 NB- 589 -631 ASTM D 1623 02/01/94 9637 -92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11/16/94 01.6739.062b[1) ASTM E 84 01/16/95 7050,02.96 -1 PA 114 03/14/96 Page 5of15 Frank Zuloaga, RRC o.. -r_,. n_...J.._. /'•....0 -..1 L'.._i.ai„u. 954 175 _sr2 May- 19 -913 03:16P Polyfoam Products Inc. POLYFOAM PRODUCrS, INC. tgoperty Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content TYPICAL PHYSICAL PROPERTIES Itzu ASTM 0 1622 ASTM U 1621 ASTM D 1623 ASTM D 2127 ASTM E 96 ASTM D 2126 ASTM D 2856 1.6 lbs. /ft.' 18 PS1 Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 I.bs./Ft 3.1 Perm / Inch +0.07% Volume Change @ ..40 F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks 86% 954 475 -1462 P•O Product Control No. -030 �,3 :t! Results Note: The physical properties listed above arc presented as typical uveragc values us determined by accepted ASTM test methods and are subject to normal manufacturing variation. Page 6of15 .v 1 : OV 1LL 1Y. J•!f Al _ J! I.l J UJ - _IU :I- 54 47_ May - 19 - 98 03:15P Polyfoam Products Inc. rrLi POLYFOAM PRODUCTS, INC. Product Control No.: 98.0303.02 SYSTEMS Deck Type: Wood, Non - insulated, New Construction/Reroof Deck Description: 15/32" or greater, plywood or wood plank. SYSTEM A: Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" 964 476 - 1462 P.O8 Undcrlaymcnt: Shall comply with Miami -Dade Roofing Application Standard PA 120 Roofing T11c: Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami -Dade County Roofing Application Standards PA 113 or PA 127. The adhesive attachment data is noted in the roof tile assembly NOA. Comments: 1. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval shall apply. Page 7 of 15 14i U U b 'lay -19 -98 03:15P Polyfoam Products Inc. . POLYFOA.M PRODUCTS, INC. Product Control No.: 98.0303.0a SYSTEMS (CONTINUED) Deck Type: Concrete, New Construction /Reroof Deck Description; New construction SYSTEM B: Adhesive Set Application Slope Range: 2 ":12" to 7 ":12" Underlayment / Install Approved underlaymcnt system of one of the following: Waterproofing: Underlayment: (30/90 Hot Mop) fully adhered in a full mopping of ASTM D 3I2 type IV asphalt applied within the bVT range. Back nailing and laps shall. be in compliance with Roofing Application Standard PA 120. Roofing Tile: Comment +: Any liquid applied roofing system having a current NOA for its use as a tile underlayment system. Any roof tile assembly having a current shall be applied in compliance with the Component Application section and the corresponding Placement Details of this Notice of Acceptance. The adhesive attachment shall provide sufficient attachment resistance expressed as a moment to meet or exceed the required moment of resistance determined in compliance with Miami•Dadc County Roofing Application Standards PA 115 or PA 127, The adhesive attachment data is noted in the roof tie assembly NOA. I. All 'System Limitations' noted in the tile Roof System Assembly Product Control Approval or waterproofing component Roofing Component Product Control Approval shall apply, as applicable. Page 8 of 15 954 475 -1462 P_09 Frank Zulnaua. RRC Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Two-Piece Barrel #1 'S' Shaped #2 Double Roll #3 Flat #4 May-19798 03:15P Po l vfoarn Products Inc. POLYFOAM PRODUCTS, INC. Product Control No.: 98.0303.02, Polypro® AI4160 tile adhesive shall only be applied over an underlayment installed in compliance with application instructions detailed in its NOA.. Underlayment may be any underlaymcnts or underlayment systems listed Miami - Dade County Roofing Application Standard PA 120. , ; Adhesive application shall be in accordance with the instructions provided herein. Trite manufacturer may provide additional instructions subsequent to this approval date which may prevail. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 3. Calibration of the Foampro8 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0- 1.15 (A) : 1.0 (B). The dispense timer shall be set to deliver 0.08 to 0.15 pounds per tile as determined at calibration. No other settings shell he approved without revision ofNOA. 4. Adhesive shall be dispensed in a 17 in' to 23 in' pad at time of application, The cured pad shall be approximately 5" x 12 ". Foam placement shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires a specific placement, as noted in Table I, below 5. Adhere tile directly in freshly applied adhesive. Tile must be set within 2 to 3 minutes after foam has been dispensed. COMPONENT APPLICATION Page 9 of 15 ,b4 4/b -1464 P.1O Frank Zuloaga, RRC May-19-9 03:16P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Product Control No.: 98- 0303.Q2 SYSTEM LIMITATIONS 2. Polypro® A14160 ndhesive shall be installed only by 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. • 3. For adhesive set tile applications, a field static uplift test by a Miami -Dade County accredited testing agency, in compliance with Mianti•Dacle County Roofing Application Standard PA 106, shall be required not Tess than 72 hours after application to confirm tile adhesion. 4. Refer to application drawings published by the National Tile Manufacturers Association for penetrations and terminations, as well as the 'Placement Details' included with NOA. 5. Refer to tile Roof Tile Assembly Product Control NOA for system acceptance with this Component. 6. Refer to the Prepared Roof Tile Assembly for fire rating. 7. Polypro® A14160 shall not be exposed permanently to sunlight. 8. Polypro® AH160 shall be applied with Fonmpro RTF1000 dispensing equipment only. 9. Polyfoam Products Inc. shall supply Building Official with a list of 'Qualified Applicators' approved and licensed by Polyfoam Products, Inc. Pac.. 10of �t 4 476-14G2 P.11 Frtnk Zuloaca, RRC EAST COAST SUPPLY 4 954 475 1462 May -19 -98 03:16P Polyfoam Products Inc. 65/19/98 16:37 POLYFOAM PRODUCTS, INC. 73 Toro o....s No.M. doom Mo A4tomh o1/r too. t►. -im.J .4. o.ws. Ms. rhos t lotto ttiw t+ •aw.o 17 to 23 oo. lochs. I. sit with Um t.» uh.. A.rssw top p..tho„ of the ows ocean* Ma. Ain* 1. .•meal o.wo. pan tht.t. Emmert ..s. owd .4 paw and Own/ Moo am Moab an w. [.w demean (pwty shoo PLACEMENT DETAILS O Oblivion' oo iGoti for Stoop OW wdk.tlo.r` '111 Prt caroms O.trd NwU thrombi, Ostia o....nt (whom r.odrod by °. Placement Detail #l; Two -Piece Barrel Profile NO.185 P001 954 475 -1462 Product Control No.: 4R -0303 02 Optionni PohlhUp Uavtor 04 11••• 0 4 thaw P.12 05/19/98 16:38 EAST COAST SUPPLY 954 475 1462 May -19 -98 03:16P Polyfoam Products Inc. POI.YFOAM PRODUCTS, INC. Ways N..u. c......,a twinm required by .made Ym.mlrfl.yn.od PLACEMENT DETAILS (CONTINUED) Dena 1.1 ... b'1C eve d..rr. Ptacetnent Detail #2: 'S' Shaped Tile Profile 954 475 -1462 £y y .ww.mekb Mk.slr. 411 ..A1.wrr 17 to 23 mN..r. brake. In nominal with tee u>_ Pamela eieerie NO.185 P002 Product Control No.: 98 -030 1540 (do. P.13 »=: 4 F e5 1462 May -19 -98 03 :16P Polyfoam Products Inc. POLYFOAM PRODUCTS, INC. Mall we . w.w a l t (w6.. , weaker $y e.rr) O PLACEMENT DETAILS (CONTINUED) Placement Detail #4: Flat Profile Page 14 of 15 954 475 - a462 Product Control No.:_ 9 &0_03_2 POLYFOAM PRODUCTS, INC. Mall ►lrsdul• Odor ic o....1 (lobos my/rod by _) rare* Cler■m 11*1 E.v. C..rs. • r •.7 • •-•o,,, r r Vu 1. . PLACEMENT DETAILS (CONTINUED) 6,. browse ..Ilr, '+ka.w+ £r r olototlry hu lVwy .werali .ol..sl.o to w•1.l... 1742 .gryy limb.. M ...toot vittt1 the tile. Placement Detail #3: Double Roll Profile Page 13 of 15 954 475 -1462 P.14 Product Control No) 98- 0303.02 Frank Zuloagg,RRC Roofing Product Crntr& F rc o., i.mv POLYFOAM PRODUCTS, INC. viotyfoatu Products, Inc. Spring- Stuebner Road ring, TX 77383 •- ,yroam Products Inc. OTI 'E OF AC EPT 954 475 - 1462 CE `TAN Product Control No. : 9 . 03 ACCEPTANCE NO: 26:231u2 APPROVED : �nril 16 199s EXPIRES : Anril 16 2OOt )AR CON 1T1 Renewal of this Acceptance (approval) shall be considered after a rrncwal application h original submitted documentation, including test supporting ' as been file d and the e tght (8) years. pp ng data, engineering documents, are no older than 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, following statement: "Miami -Dade County Product Control Approved ", or as specifically stated in th specific conditions of this Acceptance, tY. state, and the 0 3 Renewals of Acceptance will not be considered a) Mere has been a change in the South Florida Building Code affecting the evaluation of this the product is not in compliance with the code changes; product and b) The product is no longer the same product (identical) as the one originally approved; c) if the Acceptance holder has not complied with all the requirements of this acceptance inc correct installation of the product ludins the d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no !onset practicing the engineering 4 Any revision or change in the materials, use, and/or manufacture of the product or rocess shall automatic be cause for termination of this Acceptance, unless prior written filing ofa revision application with appropriate fee) and granted bythisaolff;c�cnPcqucsted (through the 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; purposes. b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or act other leer 6 The Notice of Acceptance number preceded b the words Miami-Dade County, expiration date may be displa in advertising literature. If an Florida, and followed the displayed, then it shall be done in its entirety, Y portion of the Notice of Acceptance is 7 A copy of this Acceptance as well as approved drawings and other documents, where i provided to the user by the manufacturer or its distributors and shall be available for ins action at all times. The copies need not be resealed by t applies, sits!! be y the engineer. Pd at the job site 8 Failure to comply with any s y action of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through IS. END OFF Tit i5 ACCEPTANCE Page 15 of 15 P 16 ♦y Date Mg. Wet PD2; er's Adder 10 61 M q / „, Contracting Co. ()he'©ui rb oo4 g �- 9 Q <,14., HO, ►r /Tenant Sta:e # 163-/- Municipal # Competency # 1:#306 6 Ins. Co. (2k/' �f Aviv' Arc Address Bonding Company T Address Wil Mortgagor Address Permit Type ( &orrcEe one): MIMING ELECTRICAL PLUMBING MECHANIC �OF�1� PAVING FENCE SIGN ,..---1�©© 75 2Q i� ". L �ESCI'ihltN 1�.0 j -j , � `� 4 Neap . � Q 6 1 crop Pr, Aiii,e4 reo4ii 3w Square Ft. 3 3 `d 'gm Historically Designated: Yes No Master Permit # 4 - - /q0401 WARNING TO WNEP' ?: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUTH , PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY OF YOU INTEND TO OBTAIN FINANCING, CONSULT wrai YOUR LENDE'3 O'[ AN ATT RNEY " EFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) PERMIT APPLICATION FOR MIAMI SHORES VILLAGE :ob Address // / 2 /E 7 Jt Tax Folio Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work be done in compliance all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work Sig a? arcf6f owner and/or Condo President • No ^.r as tovtt e ; astd/ar Gong to C o i .• � s. p' �.nviori �Ezla��s: •. � :. , FEES: PERMIT to Si Phone Address Q30 PP" v) nh 1]-40/ Phone , , P5 — 7,, // - 2492, Estimated Cost (value) .40,) e of Contractor or Owner- Builder Notary as to Contractor or Owner - Builder MyCommi* �ajres: J � BOND TOTAL DUE ti • I1 I.,c yr �.v�rur�iGlr�.C1111CIV 1 A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION PERMIT NO. TAX FOLIO NO: STATE OF FLORIDA: COUNTY OF DADE: 99R268055 1999 MAY 24 13:01 THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. 1 /27- A)E 'n 5&'t Preik.(; Shorn Pk 33131 1. Legal description of property and street address: 2. Description of improvement: Val 04 � JV 4 5b94 1 nio116 fib. RD/3 SySi n'/ 1 .Gt.r A -1( 3. Owner(s) name and address: (s ) a PQ� II22 �E q' S: Maw Shores Interest in property: Ol(,/t- Name and address of fee simple titleholder: 4. Contractor's name and address: Ob° lii RCoq 430/ nlf 6 &i.ld A -1401 5. Surety:(Payment bond required by owner from contractor, if any) Name and address: Amount of bond $ 1V 6. Lender's name and address: (�► 7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7., Florida Statutes, Name and address: fr 8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Name and address: 9. Expiration date, of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a different date is specified) Spr►awr� ot.ownp Print Owners Name PY2 Sworn to and subscribed before me this / day of Notary Public c,a;.',f r; C'.1 `.'"' • ry A� U) . Print Notary's Name 5 ► � � ; s � - My Commission Expires: 4 4 `' f _., OF FLORIDA, COON ! 19 of t� °. origi F4eR dd v ENV Oat p °. o G da t o ffic o on c -- � -�_ � v o ccs niY Soal. ni\O, W1/41\110. CL I ' rt .t �e} ,ndCnun9y C 40 Prepared by: ,�' ( W4, -4 Address: 409 / 1 /DA/ J r Mil F -3 0 x/ ,230,52 Contractor's Name: 0/4 0/44) O M_ A4. ROOF CATEGORY (Low Slope Application) ❑ (Nail -On Tile) ❑ (Mortar- Adhesive Set Tile) ❑ ( Metal Roofs \Wood Shingles & Shakes) ❑ (Other) ROOF TYPE ❑ New Roof ,Re roofing ❑ Recovering ❑ Repair ❑ Maintenance Flat Roof Area (ft _� 3 L Sloped Roof Area (ft') Total (ft ' ) Master Permit No. Exposure category (per ASCE 7 -88): 6 Building Classification category (per ASCE 7 -88 table 1): / ❑ (Asphalt/Fiberglass Shingles) Ft. 7 ' 6 .60 = 5 /4'' CUs — 5Arficlevoid (P', c 'qv/ a L3' ,9e4 8,4.4t.9,e( 9 11-415toror® ,clonia G,o�G6.af d Aosi Deck type: 1/00 c 4101 /C Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) g a s Y' niP p i - ATTACHMENT Fastener Type: 1/(f " Att flosouk- { /4 77 We AI SPACING ,, ■ d Field: 9 "�� o ki DETAIL 1 & 2 3Ipy otv _V X //(7 Z tto c Perimeter: d 9 i Corner: P 0 f d J `l 5 S' Job Address: /1 a2 2 7t' 6 9 r I r r r ' )( /t l S-7 3 2 7/ ( 8 ROOF PLAN 21 V PRODUCT CONTROL NOTICE OF ACCEPTANCE GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Your application for Product Approval of: GAFRuberoid® Modijed Bitumen Roof Systems for Wood Decks under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Dynatech Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -60 and the standard conditions on page 61. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. The expense of such testing will be incurred by the manufacturer. Acceptance No.: 97- 0804.14 Revises No.: 95- 1003.03 Expires: 11/06/00 Approved: 11/06/97 1 Raul Rodriguez Product Control Supervisor THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used 'n Dade County, Ft rich under the conditions set forth above. Charles Danger, P.E. Director Building Code Compliance Dept. Metropolitan Dade County Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Category: Membrane Roofing System Sub - Category: Built -up Roofing Type: Modified Bitumen Sub -Type: APP and SBS Product Control No: 97- 0804.14 Product Control No.: 97- 0804.14 Approval Date: November 6, 1997 Expiration Date: November 6, 2000 System Description GAF Materials Corporation has been manufacturing commercial roofing products for more than 100 years. GAF produces a wide range of roof products for built -up roofing systems. The modified bitumen products include both APP and SBS products in smooth, granule and fire rated versions. In addition, GAF offers two ply modified systems to meet the specification requirements for multilayer SBS modified specifications. GAF products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the Ruberoid Modified Bitumen Application and Specification manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories. GAF modified bitumen membranes have been tested in compliance with ASTM D 5147 test requirements. Contact: William J. Woodring Director of Technical Services (973) 628- 4134 Page 2 of 61 Frank Zuloaga, Roofing Product Control Examiner Insulation Types: Material Wood Basalt Wool Perlite Polyisocyanurate Composite Board Wood Fiberboard High Density Wood Fiberboard Rockwool Maximum Design Pressure Design Pressure -75psf Product Control No: 97 0804.14 Maximum Fire Classification Material Classification Wood Class'A' Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory for Fire Classifications. Page 3 of 61 Frank Zuloaga, Roofing Product Control Examiner Product GAF Asphalt Concrete Primer GAF Mineral Shield® Granules GAF WeatherCoat® Emulsion GAF Premium Fibered Aluminum Roof Coating GAF Jetblak All Weather Plastic Cement GAFGLAS #75® GAFGLAS #80 UItimaTM Base Sheet GAFGLAS Ply 6® GAFGLAS Flex PlyTM 6 GAFGLAS Ply 4® GAFGLAS® Mineral Surfaced Cap Sheet TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT Test Dimensions Specification Product Control No: 97- 0804.14 Product Description 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. 60 Ib. bags ASTM D 1863 5 gallons 1, 5 gallons 3 sq. roll 75 Ib. roll 2 Sq. Roll 70 lbs. /roll 5 sq. roll 45 lb. roll 5 sq. roll 45 Ib. roll 5 sq. roll 76 Ib. roll ASTM 1227 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. 1, 5 gallons ASTM D 2824 Fibered aluminum coating. ASTM D 3019 Refined asphalt blended with a mineral ASTM D 3409 stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4601 Asphalt impregnated and coated glass mat base sheet. ASTM D4601 Asphalt impregnated and coated, fiberglass base sheet ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type IV asphalt impregnated glass felt with asphalt coating. ASTM D 3909 Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Page 4 of 61 rank Zuloaga, Roofing Product Control Examiner Product RUBEROID® Modified Bitumen Adhesive GAFGLAS® STRATAVENT® Perforated GAFGLAS® Flashing GAFGLAS® STRATAVENT Nailable RUBEROID Modified 3 sq. roll Base Sheet 67 lbs. GAFTEMP® Isotherm R Tapered GAFTEMP® Isotherm R GAFTEMP Isotherm RA Tapered GAFTEMP Isotherm RA GAFTEMP Isotherm RN Tapered GAFTEMP Isotherm RN GAFTEMP® Composite Test Dimensions Specification 5 gallons 60 Ib. roll various 69 Ib. roll various various various various various various various ASTM D 3019 Fiber reinforced, rubberized Adhesive Type 111 ASTM D 4897 D 3672 ASTM D 489 D 3672 ASTM D4601, Premium glass fiber reinforced SBS- Type 11, UL Type modified base sheet G2 BUR PA 110 Polyisocyanurate foam insulation. PA 110 Tapered Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Tapered Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation PA 110 Tapered Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation with high dens ;ker rb board - or - _P ermaiite� perlite insu Page 5 of 61 Product Control No: 97- 0804.14 Product Description Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. Asphalt coated glass fiber mat flashing sheet available in three sizes. Fiber glass base sheet impregnated and coated on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating. Zuloaga, Roofing Product Control Examiner Product Tapered GAFTEMP® Composite GAFTEMP® Composite A Tapered GAFTEMP® Composite A GAFTEMP® Composite N Tapered GAFTEMP® Composite N GAFTEMP® Fiberboard GAFTEMP® Permalite GAFTEMP Recover Board GAFTEMP® High Density Fiberboard GAFTITE® # 12 Standard Roofing Fastener GAFTITE® #14 Heavy Duty Roofing Fastener GAFTITE ASAP Test Dimensions Specification various various various various various various various 1/2" thick various PA 110 Tapered Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Tapered Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 Tapered Polyisocyanurate foam insulation with high density fiberboard or Permalite perlite insulation. PA 110 PA 110 PA 110 PA 110 Product Control No: 97- 0804.14 Product Description Fiberboard insulation. Perlite insulation board. Perlite recover board High density wood fiberboard insulation. PA 114 Insulation fastener for steel and plywood decks. PA 114 Insulation fastener for steel, wood and concrete decks. PA 114 Pre - assembled GAFTITE Fasteners and metal and •`< < ates� T Page 6 of 61 r• uloaga, Roofing Product Control Examiner RUBEROID TORCH 1 sq. roll ASTM D 5147 Smooth 87 lbs. RUBEROID TORCH 1 sq. roll Granule 102 lbs. Page 7 of 61 Product Control No: 97- 0804.14 Test Product Product Dimensions Specification Description GAFTITE® Base PA 114 Base sheet fastening assembly. Sheet Fastener and Plate Galvalume Plates 3" and 3 '''A" PA 114 Round galvalume stress plates. NTB Fasteners PA 114 Fastener for use in gypsum, tecttim and • lightweight insulating concrete decks. Polypropylene Plates 3" and 3 'A" PA 114 Round polypropylene stress plates. Ruberoid® 20 1.5 sq. roll ASTM D 5147 SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat. Ruberoid® Mop 1 sq. roll ASTM D 5147 Non -woven polyester mat coated with Granule 103 lbs. polymer modified asphalt and surfaced with mineral granules. RUBEROID MOP 1 sq. roll ASTM D 5147 Non -woven polyester mat coated with Smooth 87 lbs. polymer modified asphalt and smooth surfaced. RUBEROID MOP 1 sq. roll ASTM D 5147 Non -woven polyster mat coated with PLUS 102 lbs. polymer modified asphalt and surfaced with mineral granules. RUBEROID MOP 1 sq. roll ASTM D 5147 Non -Woven polyester mat coated with 170FR 103 lbs. fire retardant polymer modified asphalt and surfaced with mineral granules. RUBEROID MOP FR 1 sq. roll ASTM D 5147 Non -Woven polyester mat coated with 105 lbs. fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. ASTM D 5147 Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface. Frank Zuloaga, Roofing Product Control Examiner Product RUBEROID TORCH PLUS RUBEROID TORCH FR RUBEROID 30 RUBEROID 30 FR Vent Stacks (metal and plastic) GAF Aluminum Emulsion % sq. roll 93 lbs. RUBEROID® 109. Roll ULTRACLAD® SBS 101 lbs. GAF Built -Up Roofing Asphalt Test Dimensions Specification 3 /4 sq. roll 90 lbs. 1 sq. roll 92 lbs. 1 sq. roll 92 lbs. 5 gallons GAF Aluminum Roof 5 gallons Paint 100 Ib. cartons, bulk RUBEROID MOD 60 lb. kegs Asphalt RUBEROID MOD 60 Ib. kegs Asphalt L RUBEROID MOD 60 Ib. kegs Asphalt P ASTM D 5147 ASTM D 5147 ASTM D 5147 Non woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. ASTM D 5147 Non woven fiberglass mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. PA 100(A) ASTM D 1929 ASTM D 635 None ASTM D 5147 ASTM D2824, Type! ASTM D312, Types 1, 11, III and 1V Page 8 of 61 Product Control No: 97- 0804.14 Product Description Heavy duty, polyester reinforced, asphalt modified bitumen membrane, granule surface Heavy duty, polyester reinforced, coated with fire retardant asphalt modified bitumen membrane, granule surface. One way valve vent used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. Mineral colloidal bituminous emulsion with reflective aluminum flakes Woven fiberglass mat coated with Polymer modified asphalt surfaced with aluminum, copper or stainless steel foil. Non - fibered. aluminum pigmented, asphalt roof coating Interply mopping and surfacing asphalt SEBS modified asphalt SEBS modified asphalt SEBS modified asphalt Frank Zuloaga, Roofing Product Control Examiner Product GAFTEMP Tapered Various PA 110 Tapered polyisocyanurate foam Isotherm R GAFTEMP Tapered Various PA 110 Tapered polyisocyanurate foam Isotherm RA GAFTEMP Tapered Various Tapered polyisocyanurate foam Isotherm RN GAFTEMP Various Cut perlite board GAFCANTTM GAFTEMP Various Tapered perlite board GAFEDGETM Tapered Edge Strip GAFTEMP PERMALITE® Tapered Roof Insulation Various GAFTEMP Recover 112" thick, Board Various sizes Shingle- MateT"' 4 sq. roll Underlayment 30 Ibs. GAFTITE® ASAP 500 per box RUBEROID® Modified Bitumen Adhesive Test Product Dimensions Specification Description 5 gallons PA 110 Tapered perlite board PA 110 Perlite board ASTM D 3019 Type I1I Page 9 of 61 Product Control No: 97 0804.14 Fiberglass reinforced shingle underlayment PA 114 Pre - assembled fastener and metal and plastic plates Fiber reinforced, rubberized Adhesive Qom! A" ! - J twill oaga,— `"•Ming Product Control Examiner Pyrox Product ACFoam 1 ACFoam 11 Anchorbond Fastener Dekfast Fasteners #14 Dekfast Hex Plate TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Dimensions Specification various various various 3 1/4" PA 110 Polyisocyanurate foam insulation PA 110 Product Description Polyisocyanurate foam insulation PA 110 Polyisocyanurate foam insulation Hy -Therm Nail -line various PA 110 Polyisocyanurate foam insulation Hy -Therm SP various PA 110 Polyisocyanurate foam insulation. Hy -Therm AP various PA 110 Polyisocyanurate foam insulation Hy -Therm Stable R various PA 110 Polyisocyanurate foam insulation Hy -Therm White various PA 110 Polyisocyanurate foam Line insulation PA 114 Insulation fastening assembly PA 114 Insulation fastener for steel and concrete decks 2 7/8" x PA 114 Galvalume hex stress plate. Page 10 of 61 Product Control No: 97- 0804.14 Manufacturer Apache Products Co. (with current PCA) Atlas Energy Products (with current PCA) Atlas Energy Products (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Celotex Corp. (with current PCA) Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) Fan- Zuloaga, Roofing Product Control Examiner Test Product Product Dimensions Specification Description Product Control No: 97- 0804.14 Manufacturer Dekfast Lock Plate 3" x 3 1/4" PA 114 Polypropylene locking Construction plate. Fasteners Inc. (with current PCA) Dekfast Fasteners #15 Dekfast Fasteners #12 PA 114 Insulation fasteners for Construction concrete decks Fasteners inc. (with current PCA) PA 114 Insulation fastener for steel Construction and wood decks. Fasteners Inc. (with current PCA) ISO 95+ Composite PA 110 Polyisocyanurate / perlite Firestone ridged insulation (with current PCA) Asphalt ASTM D 312 Type III or IV Hot asphlat generic bitumin adhesive Asphalt Primer ASTM D 41 Asphalt Primer generic EPS various PA 110 Extruded polystyrene generic insulation High Density Wood various PA 110 Wood fiber insulation board generic Fiberboard Pelite /Urethane various PA 110 Perlite / urethane composite generic Composite board insulation Perlite Insulation various PA 110 Perlite insulation board generic Polyethylene 4 mil min. Vapor barrier / Air barrier generic Red Rosin various Rosin paper for barrier generic layer on wood decks Roofing Nails Minimum # PA 114 Corrosion resistant annular generic 12 ring shank nails Page 11 of 61 uloaga, __ __ Roofing Product Control Examiner Tin Caps Product MB aluminum roof coating Dens -Deck #12 Roofgrip #14 Roofgrip Gripdek Fastener ISO 95+ E'NRG'Y -2 I SORoc Test Dimensions Specification Min. 32 ga. x 19," various Hexcel Fastener PA 114 Hextra PA 114 Standard Plastic 3" round PA 114 Plate various PA 110 various PA 110 Product Description Corrosion resistant circular discs. PA 121 Aluminum roof coating PA 110 Gypsum insulation board. PA 114 Insulation fastener for steel or wood decks PA 114 Insulation fastener steel, wood or concrete decks PA 114 Insulation fastener Insulation fastener Insulation fastener and metal or plastic plate Polyolefin plastic plate Polyisocyanurate foam insulation various PA 110 Polyisocyanurate foam insulation Polyisocyanurate foam / rockwool composite insulation Page 12 of 61 Product Control No: 97- 0804.14 Manufacturer generic Grundy Industries (with current PCA) Georgia Pacific (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) International Permalite (with current PCA) NRG Barriers, Inc. (with current PCA) NRG Barriers. Inc. (with current PCA) Frank Zuloaga, Roofing Product Control Examiner Product Olympic Standard Olympic Fastener #14 Olympic Polypropylene Olympic Fastener #12 Olympic Fastener ASAP Olympic CR Base Felt Fastener and Base Sheet Disc GlasFast Fastener Paroc Base Board Paroc Cap Board Test Dimensions Specification 3" round 3.25" round various various PA 114 PA 114 PA 114 Page 13 of 61 Product Description 3" round galvalume AZ55 steel plate PA 114 Insulation fastener PA 114 Polypropylene plastic plate PA 114 Insulation fastener PA 114 Pre - assembled Insulation fastener and plate Insulation fastener assembly for Base Sheet fastening only Insulation fastener assembly with recessed plastic plate PA 110 Rockwool insulation PA 110 Rockwool insulation Product Control No: 97- 0804.14 Manufacturer Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic . Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Owens - Corning Fiberglas Corp. (with current PCA) Partek, Inc. (with current PCA) Partek, Inc. (with current PCA) uioaga, Roofing Product Control Examiner U ItraGard Product lnsul -Fixx Fastener lnsul -Fixx P Rawl Fasteners #12 Rawl Fasteners #14 Rawl 2" Plate Rawl 3" Plate Rawlite 3" Plate 202 HS Super Prep 11 Tru -Fast DL Test Dimensions Specification various 3" round 2" round 3" round 3" round Product Description PA 110 Polyisocyanurate foam insulation PA 114 Insulation fastener for steel and wood decks PA 114 * 3" round polyethylene stress plate PA 114 Insulation fastener for steel and wood decks PA 114 Insulation fastener for use in steel, wood or concrete PA 114 2" round galvalume AZ55 membrane plate PA 114 3" round galvalume AZ55 steel plate PA 114 3" round galvalume AZ55 steel plate for use with Rawlite fasteners PA 121 Roof coating PA 121 Roof coating PA 114 Insulation fastener for steel, or wood Page 14 of 61 Product Control No: 97- 0804.14 Manufacturer Schuller International Inc. (with current PCA) SFS /Stadler (with current PCA) SFS /Stadler (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) The Rawlplug Company Inc. (with current PCA) Thermo- Materials. Inc. (with current PCA) Thermo- Materials, Inc. (with current PCA) Tru -Fast ith -parrerrt -A4_ Frank Zuloaga, Roofing Product Control Examiner Test Product Dimensions Specification Tru -Fast Plastic 3.04" round Plate Tru -Fast MP -3 3.23" round Tru -Fast HD Tru -Fast Ultra Tru -Fast DP Tru -Fast TP Structodeck various Product Description PA 114 3.04" round polyethylene plastic plate PA 114 3.23" round galvalume AZ50 steel plate PA 1 14 Insulation fastener for use in wood, steel or concrete decks PA 114 Stainless Steel fastener for use in steel, wood and concrete decks PA 114 Insulation fastener for use in steel or wood decks PA 114 Insulation fastener for use in steel or wood decks PA 110 High density wood fiber Page 15 of 61 Product Control No: 97- 0804.14 Manufacturer Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) -Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Wood Fiber Industries (with current PCA) " Zuloaga, Roofing Product Control Examiner Test Agency /Identifier Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Corporation Factory Mutual Research Wind Uplift, FMRC Corp. 4470 - PA 114 Factory Mutual Research Wind Uplift, FMRC Corp. 4470 - PA 114 Trinity Engineering Wind Uplift PA 114 Underwriters Laboratories, Inc. Name Current Insulation Attachment Requirements Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Wind Uplift FMRC 4470 - PA 114 Fire Resistance Classification UL 790 - PA 114 Dynatech Engineering Wind Uplift Corporation PA 114 TEST REPORTS Report FMRC 1996 J.I. OT4A I.AM J.1. 1 V8A4.AM J.1. 1RIA6.AM J.I. 0T2Q4.AM J.1. 0Q6A6.AM J.1. 3X3A2.AM J.1. 0Y9Q5.AM J.I. 1 B9A8.AM J.I. 3D4Q2.AM 4483.04 97 -1 R1306, 87NK11819 #3600.02.95 -1 Page 16 of 61 Product Control No: 97 0804.14 Date 01.01.96 08.26.92 06.28.93 11.15.91 10.17.91 07.16.91 08.02.94 07.29.94 09.04.97 04.30.97 06.06.97 01.01.93 02.02.95 rank Zuloaga, Roofing Product Control Examiner Test Agency/Identifier Dynatech Engineering Corporation Product Control No: 97- 0804.14 Name Report Date Wind Uplift #4482.02.95 -1 02.02.95 PA 114 Page 17 of 61 ran Zuloaga, Roofing Product Control Examiner Membrane Type: SBS Deck Type 1: Wood, Non - insulated New Construction or Reroof Deck Description: I9 / or greater plywood or wood plank decks System Type A(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Base Sheet: Ply Sheet: Membrane: Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb. /sq. and 300 lb. /sq. respectively in a flood coat of approved asphalt at 60 lb. /sq.. Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: GAFGLAS® #75, GAFGLAS #80 Uhlma Base Sheet, GAFGLAS® PLY 4 ®, GAFGLAS® PLY 6 ®, GAFGLAS FlexPlyTm Base Sheet,GAFGLAS® STRATAVENT® Nailable, RUBEROID Modified Base Sheet or RUBEROID® 20 applied to the deck with approved annular ring shank nails and minimum 1 '/ tin caps at a fastener spacing of 9" o.c. at the lap, 12" o.c. in two rows staggered along the center line of the sheet in the field. (Optional) One, two, or three plies GAFGLAS PLY 4 ®, GAFGLAS® PLY 6® Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. One or more plies of RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, Ruberoid® Mop Plus Granule, Ruberoid® 30 or Ruberoid® 30 FR or Ruberoid® Mop FR or RUBEROID UltraCladTM SBS in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. Or, One or more plies of RUBEROID MOP Smooth, RUBEROID® Mop Granule, RUBEROID® Mop 170 FR, RUBEROID® Mop Plus Granule, RUBEROID® 30, RUBEROID® 30 FR or RUBEROID® Mop FR or RUBEROID UltraCladTM SBS in RUBEROID Modified Bitumen Adhesive at an application rate of 1 -2 gal. /sq. -45 psf (See General Limitation #7) 'A'. See General Limitation #2. 2 ":12 "; See General Limitation #3. Page 22 of 61 Product Control No: 97- 0804.14 GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lb./sq. + 15 %. --- , ,,,, ) ---, Frank Zuloaga, Roofing Product Control Examiner 4. ''A Type X gypsum board is acceptable to be installed directly over the wood deck.. Page 57of61 Product Control No: 97- 0804.14 Wood Deck System Limitations: 1. Fastener spacing for anchor sheet attachment is based on a Minimum Characteristic Force (F') of 95 Ibf or greater as tested in compliance with Merto -Dade County Protocol PA 105. If F' as tested is below 95 Ibf, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from Merto -Dade County Protocol PA 105 and calculations in compliance with Metro -Dade Roofing Application Stanadrd PA 117. 2 All standard insulation panel sizes are acceptable for mechanical attachment. When parcels are applied in hot asphalt, maximum panel size shall be 4' x 4'. a. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') of 275 lbf. as tested in compliance with Merto -Dade County Protocol PA 105 & Roofing Application Standard PA 117. If the fastener value, as field tested, are below 275-Ibf. insulation attachment shall not be acceptable. 3 A slip sheet is required with GAFGLAS FIexPly 4® and Ply 6® when used as a mechanically fastened base or anchor sheet. Frank Zuloaga, Roofing Product Control Examiner GENERAL LIMITATIONS Page 58 of 61 Product Control No: 97- 0804.14 1 All asphalt shall comply with ASTM D 312 type III or type IV requirements, and approved by applicant. 2 Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3 Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4 An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used, install one layer of GAFGLASS STRATAVENT Perforated, laid dry.A base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. Where STRATAVENT Perforated is used over approved isocyanurate foam insulation, the maximum design pressure is limited to —60psf. 5 All work shall be performed by a contractor licensed to do roofing work in Metro -Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer, and the requirements of the SFBC. 6 The submission of system specifications and details shall accompany the Section II Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. Zuloaga, Roofing Product Control Examiner Product Control No: 97- 0804.14 7 Perimeter and corner areas shall comply with the enhanced uplift pressure of these areas, as calculated in compliance with Chapter 23 of the South Florida Building Code. Fastener densities shall be increase for both insulation and base sheet as needed calculated in compliance with Metro -Dade County Roofing Application Standard PA 117. (When this limitation is specifically referred within this NOA, General Limitation #20 will not be applicable.) 8 All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Metro - Dade County Roofing Application Standard PA 1.11 and the wind load requirements of Chapter. 23 of the South Florida Building Code. 9 Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with the Section II Permit Application. All details shall comply with the provision of the South Florida Building Code. 10 Fastener spacing for base sheet attachment is based on a Minimum Characteristic Force (F') value as tested in compliance with Metro -Dade County Protocol PA 105. If the fastener values as tested are below those listed in the System Limitations, a professional engineer may submit a revised fastener spacing utilizing the withdrawal resistance value taken from a Metro - Dade County Protocol PA 105 test report and calculations that comply with the wind Toad requirements of Chapter 23 of the South Florida Building Code and Roofing Application Standard PA 117. 11 Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 Ibf., as tested in compliance with PA 105. if the fastener value, as field tested, are below 275 lbf. insulation attachment shall not be acceptable. 12 Asphalt moppings shall be with applied with approved asphalt and shall be in compliance with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 13 Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive, which shall comply with provision of Roofing Application Standard PA 117 0,/ Page 59 of 61 rank Zuloaga, Roofing Product Control Examiner Product Control No: 97- 0804.14 14 All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 15 In re- covery/re- roofing applications, prior to the application, all existing roof surfaces used as a bonding substrate shall be tested in compliance with Metro -Dade County Protocol PA 124 for uplift resistance. Test pressures shall be calculated in compliance with the wind Toad requirements of Chapter 23 of the South Florida Building Code to the design pressure of the roof. 16 In re- roofing applications, moisture content in an existing roof must be in compliance with Section 3401.10(m), (n) of the South Florida Building Code. 17 Roll good materials shall be stored on end and on a clean, flat and dry surface. 18 If required, any Factory Mutual Approved vapor barrier in conjunction with 'proprietary or approved adhesives may be used prior to the application of the insulation layer. 19 Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with sections 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 20 The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners, and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) Page 60 of 61 Frank Zuloaga, Roofing Product Control Examiner ,e: GAF Materials Corporation ACCEPTANCE NO.: 97- 0814.14 1361 Alps Road APPROVED: November 6, 1997 Wayne, NJ 07470 EXPIRES: November 6, 2000 1 NOTICE OF ACCEPTANCE STANDARD CONDITIONS Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the original submitted documentation, including test supporting data, engineering documents, are no older than eight (8) years. 2 Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the specific conditions of this Acceptance. 3 Renewals of Acceptance will not be considered if: a) There has been a change in the South Florida Building Code affecting the evaluation of this product and the product is not in compliance with the code changes; b) The product is no longer the same product (identical) as the one originally approved; c) If the Acceptance holder has not complied with all the requirements of this acceptance, including the correct installation of the product; d) The engineer who originally prepared, signed and sealed the required documentation initially submitted, is no longer practicing the engineering profession. 4 Any revision or change in the materials, use, and/or manufacture of the product or process shall automatically be cause for termination of this Acceptance, unless prior written approval has been requested (through the filing of a revision application with appropriate fee) and granted by this office. 5 Any of the following shall also be grounds for removal of this Acceptance: a) Unsatisfactory performance of this product or process; b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other purposes. 6 The Notice of Acceptance number preceded by the words Metro -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is displayed, then it shall be done in its entirety. 7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at all times. The copies need not be resealed by the engineer. 8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of Acceptance. 9 This Acceptance contains pages 1 through 61 END OF THIS ACCEPTANCE Page 61 of 61 Product Control No: 97 0804.14 Frank Zuloaga, Roofing Product Control Examiner ROOF COVERING MATERIALS (TEVT) 1999 Roofing Mate ROOFING SYSTEMS (TGFU)— Continued 29. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or 'Poly -Iso Special" with "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or three applications, applied 1 -1/4 gal /sq /application (16 -32 dry mils). Surfacing: "Gacoflex UA -65" Series (various colors), applied 1 gal /sq (12 dry mils). 30. Deck: NC Incline: 1/2 Foam: "Poly -Iso" or 'Poly -Iso Special" with "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or three applications, applied 1 -1/4 gal /sq /application (16 -32 dry mils). Surfacing: "Gacoflex UA -60" Series (various colors), applied 1 gal /sq (15 dry mils). 31. Deck: NC Incline: 2 Foam: "Poly -Iso' or 'Poly -Iso Special" with "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat: "GacoSil S- 1000 ", applied at 1 gal /sq (10 dry mils). Surfacing: "Gacoflex 5- 1000 ", applied at 1 gal /sq (10 dry mils). 32. Deck: NC Incline: 1 Foam: "Polyfoam 251" or "Polyfoam 303", any thickness. Surfacing: "Gacoflex Ure- Shield 7007 ", 40 dry mils. 33. Deck: NC Incline: 2 Foam: "Polyfoam 275 ", any thickness. Base Coat: "Gacoflex A- 6211 ", 1 -1/2 gal /sq (14 dry mils). Surfacing: "Gacoflex A- 6200" series (various colors), 1 -1/2 gal /sq (14 dry mils). 34. Deck: NC Incline: 2 Foam: Polyfoam 251, "Polyfoam 275" or "Polyfoam 303 ", any thickness. Base Coat: One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq. /application (16 -32 dry mils). Surfacing: One application of "Gacoflex A -55 Series" (various colors), applied at 1 -1/2 gal /sq. (15 dry mils). 35. Deck: NC Incline: 1/4 Foam: "Polyfoam 251 ", "Polyfoam 275" or "Polyfoam 303 ", any thickness. Base Coat: "Gacoflex UB -64," applied at 1 -1/2 gal /sq. (18 dry mils). Trowel Coat: 30/60 mesh crushed walnut shells mixed at a rate of 5 lb /gal with "Gacoflex UB -64," applied at 1 -1/2 gal /sq or "Gacoflex UB -64 ", applied at 1 -1/2 gal /sq (18 dry mils) followed by the broadcast application of 30/60 mesh crushed walnut shells applied at 7 -8 lb /sq. Surfacing: "Gacoflex U -66 ", applied at 1/2 gal /sq. (6 dry mils). R1306 GAF MATERIALS CORP 1361 ALPS RD, WAYNE NJ 07470 "RUBEROID 20" or "RUBEROID Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) Georgia- Pacific "Dens - Decks" overlayment board may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Also, multiple plies of "GAFGLAS Ply 4" or "Ply 6" may be adhered to "Dens- Deck" in hot asphalt. "GAFGLAS Stratavent Nailable Base Sheet" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. GAFGLAS Perlite Insulation may be utilized as a cover board over "EVERGUARD" insulation in any of the following systems. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or "GAFGLAS #80 Premimum Base Sheet ") is a suitable alternate for Type 61 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAFGLAS Stratavent (Vent -Ply) perforated" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet ", "GAFGLAS #80 Premium Base Sheet" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks ") may be substituted for 61 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. i Systems Directory ROOF COVERING MATERIALS (TEVT) 141 ROOFING SYSTEMS (TGFU)— Continued "GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes " GAFTEMP PERMALITE'" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A. B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin paper (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the following Class A, B or C systems. "GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and ' GAFTEMP Composite A" may be substituted for any isocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt ". GAFGLAS #80 Premium Base Sheet may be used in any of the following systems. Class A, B and C. Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type 61 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type 61 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". 3. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic, 2 in. max. Ply Sheet: Two or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet'. 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in. max, hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. 5. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet: One or more layers of Type 61 "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet'. 6. Deck: NC Incline: 3 Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet ". Ply Sheet: One or more layers of Type 61 "GAFGLAS Ply 4" or GAFGLAS Ply 6 ". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". 7. Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane. perlite /isocyanurate composite, perlite /urethane composite, phenolic. 1.0 in. min (offset from plywood joints 6 in.). Base Sheet: One or more layers of Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule). "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Cap Sheet: "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. 8. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite, urethane composite, wood fiber /isocyanurate composite, phenolic, an ■ thickness. LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) ROOFING SYSTEMS (TGFU)— Continued , in. (min) Georgia- Pacific "Dens Deck® Overlayment" are used directly he deck with all joints staggered 6 in. (min) from plywood joints. vapor barrior may be optionally installed under all systems utilizing GUARD" insulation. "EVERGUARD" insulation is an acceptable alternate y polyisocyanurate insulation of the following systems. GAFGLAS e may be used as an option over EVERGUARD insulation. GAFGLAS vent Perforated Base Sheet may be utilized as an additional ply in f the following systems. Class A - Ballasted eck: NC Incline: 2 Insulation: One or two layers "Isotherm R ", any thickness, loose laid or mechanically fastened. Membrane: Any UL Classified membrane used in a ballasted system. Surfacing: River bottom stone, 3/4 to 1 -1/2 in. diam, 1000 lbs /sq. eck: C -15/32 Incline: 1/4 (NC -2) Insulation: Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Membrane: "Ruberoid Torch 1" (modified bitumen). Surfacing: Gravel at 400 lbs /sq, loose laid or concrete blocks, at 10 lbs /sq and spaced not more than 1/8 in. eck: NC Incline: 3 Insulation (Optional): Perlite, glass fiber or wood fiber, 3/4 to 1 -1/2 in. Base Sheet (Optional): Type 15 asphalt organic felt or Type G2. Membrane: "Ruberoid` Torch 1" (modified bitumen). Surfacing: Gravel. eck: C -15/32 Incline: 1/4 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness. Membrane: "Ruberoid® Torch 1" (modified bitumen). Slip Sheet: 0.004 in. polyethylene (not UL Classified). Surfacing: 3/4 in. thick concrete with one layer of No. 10 Summerville Quarry tile (or equivalent) grouted in place. eck: NC Incline: 2 Insulation (Optional): Perlite, glass fiber or wood fiber, any thickness. Membrane: "Ruberroid® Torch 1" (modified bitumen). Surfacing: 3/4 to 1 -1/2 in. diam river bottom stone at 1000 lb /sq or concrete pavers weighing not less than 10 lb /sq ft and spaced not more than 1/8 in. eck: NC Incline: 3 Insulation: a)Polystyrene, 2 in. max, b)Isocyanurate, any thickness, laid .00sely. Membrane: "EverGuard SR" or "EverGuard FB ", 40 -100 mil (TPA), laid .00sely. Surfacing: River bottom stone (3/4 - 1 -1/2 in. diam) at 1000 lb /sq or :oncrete roof pavers. Class A - Fully Adhered eck: NC Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber. isocyanurate, urethane, perlite /isocyanurate composite, perlite/ Jret hane composite, wood fiber /isocyanurate composite, phenotic, any thickness. Base Sheet (Optional): One or more layers Type G3, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (smooth or granule), 'Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or 'Ruberoid Mop Plus" (granule). Surfacing: Gravel, 400 lbs /sq, loose laid or applied in a flood coat of hot - oofing asphalt. eck: NC Incline: 1/2 Base Sheet (Optional): One or more layers Type G1, G2 or G3. Membrane: One or more layers "Ruberoid Torch" (smooth or granule), 'Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or 'Ruberoid Mop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. eck: NC Incline: 1/4 insulation (Optional): One or more layers perlite, wood fiber, glass fiber, any thickness. Base Sheet (Optional): One or more layers Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), 'Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Hop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. eck: C -15/32 Incline: 1/2 insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, )erlite /isocyanurate composite, perlite /urethane composite, phenolic, 1-1/2 in. min thickness (offset from plywood joints 6 in.). 3ase Sheet: One or more layers of Type G2 or G3. 'ly Sheet (Optional): One or more layers of Type GI. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq. 'ck: NC Incline: 1/2 1999 Roofing Materials and Systems Directory LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) 143 ROOFING SYSTEMS (TGFU)— Continued Base Sheet (Optional): One or more layers of Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granute). Surfacing (Optional): Karnak "No. 97" or "169" at 1 -3 gal /sq or Grundy Ind. "20 F Emulsion" at 3 gal /sq. 6. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Gravel. 7. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, wood fiber /isocyanurate composite, phenolic. Base Sheet: Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type G1. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq or gravel. 8. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: "AL MB Aluminum Roof Coating" at 1 -2 gat /sq. 9. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenotic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4 ", hot mopped in place. Membrane: "Ruberoid Mop FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gat /sq. 10. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Pty 4 ", or "GAFGLAS Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optionat): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 11. Deck C -15/32 Incline: 1/2 Insulation: Isocyanurate, 2 in. min., wood fiber, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet (Optional: One or more layers of Type G1 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 12. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Isocyanurate, perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type 01 "GAFGLAS Ply 4" or "Ply 6 ", hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 13. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. 3 I 144 ROOF COVERING MATERIALS (TEVT) 1999 Roofing Materials and Systems Directory ROOFING SYSTEMS (TGFU)— Continued Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped in place. Ply Sheet (Optional): One or more layers of Type 61 "GAFGLAS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): "GAF Fibered Aluminum Coating" at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 14. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood fiber board, perlite, glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of "GAFGLAS #75 Base Sheet ", hot mopped in place. Ply Sheet (Optional): One or more layers of "GAF GLAS Ply 4" or "Pty 6" hot mopped in place. Membrane: "Ruberoid Torch 170FR" (granule). Surfacing (Optional): GAF Weather Coat Emulsion applied at 3 gal /sq or GAF Fibered Aluminum Coating at 1 -1/2 gal /sq. 15. Deck: C -15/32 Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane, pertite isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type 61, hot mopped in place. Membrane: "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 1 ec : -15/32 Tncttne: t/4 Insulation (Optional): Pertite, fiber glass, isocyanurate, urethane, perlite/ isocyanurate composite or phenolic, offset 6 in. from joints. Base Sheet: One or more layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" or "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch 170FR" or "Ruberoid Mop FR" (granule) 17. Deck: NC Incline: 1 Insulation (Optional): Pertite, fiber glass, wood fiber, isocyanurate, urethane, pertite/isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers Type 61, hot mopped in place. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 18. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic. Base Sheet (Optional): One or more layers of Type G -2 or G -3 base sheet, hot mopped or mechanically fastened. Ply Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membrane: One layer of "Ruberoid Torch" (smooth), "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch 170FR ", "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers of perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite or phenolic, any thickness. Base Sheet: One or more plies 61 or G2, hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal /sq. Membrane: One layer of "Ruberoid Mop FR" or "Ruberoid Mop 170 FR" (granule), hot mopped or adhered with Karnak Chemical Co. "No. 81" or Gibson -Homan "No. 6160" cold applied adhesive at 1 -1/2 gal /sq. 20. Deck: C -15/32 Incline: 1/4 Insulation: Polyisocyanurate, any thickness. Base Sheet: "GAFGLAS #75" (Type G2), mechanically attached. Membrane: One or more plies of "Rubberoid Torch (smooth). Membrane: "Ruberoid Torch 170FR" (granule). 21. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies of Type G2 "GAFGLAS #75" or "Ruberoid 20 FR" base sheets, hot mopped or mechanically fastened. Membrane: One or more plies of "Ruberoid 30 FR" hot mopped in place. 22. Deck: C -15/32 Incline: 1 Insulation (Optional): Polyisocyanurate, wood fiber, perlite, or glass fiber any thickness, hot mopped or mechanically fastened. Base Sheet: One or more plies of Type G2 "GAFGLAS #75" hot mopped or mechanically fastened. ROOFING SYSTEMS (TGFU)— Continued Ply Sheet: One or more plies of "Ruberoid 20" or "Ruberoid 20 FR ", hot mopped in place. Membrane: One or more plies of "Ruberoid 30 FR ", hot mopped in place. 23. Deck: C -15/32 Incline: 1/2 Insulation (Optional): Fiber glass or perlite, mechanically fastened. Base Sheet: One or more layers Type G2, hot mopped or mechanically fastened. Ply Sheet: Two or more layers Type G1, hot mopped or mechanically fastened. Membrane: "Ruberoid 30" or "Ruberoid Modified Cap Sheet 601 ", hot mopped in place. 24. Deck: NC Incline: 1/4 Insulation (Optional): Polyisocyanurate, perlite, glass fiber or wood fiber, 2 in. max. Base Sheet: Type 15 asphalt organic felt, Type G2 or "Flex Base 60 (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid` Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" or "Karnak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal /sq. Incline: 1/4 25. Deck: C -15/32 Insulation: Two layers glass fiber (staggered joints), 1 in. each. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: 'Ruberoid' Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gal /sq. 26. Deck: NC Incline: 1/4 Membrane: 'Ruberoid` Torch 1" (modified bitumen). Surfacing: Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating" at 1 to 2 gat /sq. 27. Deck: NC Incline: 1/2 Insulation (Optional): Perlite, wood fiber or glass fiber, 1 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2 or "Flex Base 60" (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid' Torch 1 ", heat fused. Surfacing: Monsey Products "Endure Aluminum Roof Coating'. "'Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq. 28. Deck: NC Incline: 1 -2 Insulation (Optional): Perlite, wood fiber, glass fiber or isocyanurate. urethane board, 2 in. max, mechanically fastened. Base Sheet: Type G2 (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid" Torch 1" (modified bitumen), heat fused. Surfacing: Monsey Products "Dura- White ", "Endure White Etastomeric Roof Coating" or "Pro -Grade White Etastomeric Roof Coating 3 gal /sq. 29. Deck: NC Incline: No limitation Insulation (Optional): Polyisocyanurate, urethane, glass fiber, perlite. wood fiber, any combination in any thickness, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2 (modified bitumen), mechanically fastened. Membrane: 'Ruberoid' Torch 1 ", heat fused. Surfacing: "Tuff- Corp" field mixed insulating coating composed of 6 -7/3 cu ft of pertite, 7 lb of "TC -500 Masterbatch", 94 lb Portland cement and 17 gal of water spray applied to min 1/2 in. 30. Deck: C -15/32 Incline: No limitation Insulation (Optional): Polyisocyanurate, urethane, glass fiber, perlite, any combination in any thickness, mechanically fastened. Base sheet: Type G2 (modified bitumen), mechanically fastened or adhered with hot roofing asphalt. Membrane: 'Ruberoid Torch 1 ", heat fused. Surfacing: "Tuff- Corp" field mixed insulating coating composed of 6 -2 3 cu ft of perlite, 7 lb of "TC -500 Masterbatch ", 94 lb Portland cement and 17 gat of water spray applied to min 1/2 in. 31. Deck: NC Incline: 1/2 Insulation (Optional): Glass fiber, perlite, wood fiber, 1 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: "Ruberoid" Torch 1" (modified bitumen), heat fused. Surfacing: Henry "No. 229 Asphalt Emulsion" at 1 gat /sq or GEO Industries "No. 929 Aluminum Emulsion" at 1 gal /sq. 32. Deck: NC Incline: 1/2 Insulation: Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened any thickness. Base Sheet: Type G2, mechanically fastened or hot mopped. Membrane: "Ruberoid 9 Torch 1 ", heat fused in place. Surfacing: Henry, "Henry 520 Aluminum ", applied at 1 -1/2 gal /sq. LOOK FOR THE UL MARK ON PRODUCT ROOF COVERING MATERIALS (TEVT) PERMIT APPLICATION FOR MIAMI SHORES VILLAGE Date Job Address /J Z / / 77 fr Tax Folio Legal Description Historically Designated: Yes No / Tenant An': ,o_ , 0 K.17 Master Permit # % % ,/,_ , Owner's Address // -2- // ' 4 7/ fr Phone Contracting Co. V Pf GL7 AZ/P AO / Address 7 t" -,,(/ i t/C . -- /9/S Qualifier 7a ,!'r°4 Phone g Z.-,p State # AC 69KS 9 e Municipal # Competency # AVV Ins. Co. „k Architect/Engineer Address Bonding Company Address Mortgagor Address Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL / & ° ‹ Z C WORK DESCRIPTION Square Ft. Afr6 1:4` WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.) Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated. Signature of owner and/or Condo President Notary as to Owner and/or Condo President My Commission Expires: D CAROLYN C ROHE My Comm Exp. 5/08/99 onded By Service Ins No. CC460657 17 Pmon.f r Knows CI Oma L D. C? ate ate RADON C.C. `It G ° NOTARY BOND APPROVED: Zoning Buildihg t" G Mechanical Plumbing Estimated Cost (value) Gas �C.�•v� �' PAVING FENCE SIGN Signature of �cto#or Owner- Builder 2. Notary as Contractor or O or- ai + . NOTARYSGA Date My Commission Expires: LYNNE 3ACALEZ2 N OTARY PUBLIC STAY Cl: t"LG:i;:"DA COMMISSION NO. CC5 2S'32 MY COMMISSION EXP. CC'. 13 3 Electrical ate Engineering Contractor's Name: • Avii ROOF CATEGORY ❑ (Nail -On Tile) ❑ ( Metal Roofs\Wood Shingles & Shakes) ROOF TYPE ❑ New Roof ''Re roofing ❑ Recovering LIZ (Low Slope Application) ❑ (Asphalt/Fiberglass Shingles) Flat Roof Area (ft') kr rd Sloped Roof Area (ft) Total (ft') AO Master Permit No. Exposure category (per ASCE 7 -88): Building Classification category (per ASCE 7 -88 table 1): ROOF HEIGHT AND SYSTEM DETAILS (Draw details as needed) .0 ,‘ C p s Add" 64of 6 'f") 94,6 17,J a4 412.d /..v Fastener Type: ,/ ��_�5'��✓d Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. ATTACHMENT SPACING Field: Perimeter: Corner: i s DETAIL 1 & 2 Job Address: ❑ Repair ❑ Maintenance r ❑ (Mortar - Adhesive Set Tile) ❑ (Other) ROOF PLAN Ridge Ventilation? MEAN HEIGHT Deck type: Underlayment: Appendix "E" UNIFORM ROOFING PERMIT APPLICATION PROCESS No. Insulation: Fastener type & spacing: 12" ROOT SLOPS D E T A I L 3 SLOPED SYSTEM DESCRIPTION Cap Sheet: Roof Covering: Page -2 Drip edge: ATTACHMENTS REQUIRED 1) Fire Directory Listing Page 2) Dade County Product Control Notice of Acceptance - Cover Sheet a) Specific System Description b) Specific System Limitation,' c) General Limitations d) Applicable Detail Drawings 3) Municipal Permit Application 4) Other Component Approvals TILE CALCULATIONS (Pmaxl: x a, (Aerodynamic Multiplier): ) - M = M PCA: (Pmax2: x A, (Aerodynamic Multiplier): ) - M = M PCA: (Pmax3: x X (Aerodynamic Multiplier): ) - M = M PCA: METRO -DADE APPROVED: 03/14/96 PRODUCT CONTROL NOTICE OF ACCEPTANCE GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 The expense of such testing will be incurred by the manufacturer. ACCEPTANCE NO.: 95- 1003.03 Revises No.: 94- 1014.01 EXPIRES: 11/10/97 1 • METROPOLITAN DADE COUNTY, FLORIDA • - METRO -DADE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE SUITE 1603 METRO DADE FLAGLER BUILDING 140 WEST FLAGLER STREET MIAMI, FLORIDA 33130 -1563 (305) 375 -2901 FAX (305) 375 -2908 INTERNET: mdcc01@shadow.net Your application for Product Approval of: PRODUCT CONTROL SECTION (305) 375 -2902 GAF Conventional Built -Up Roof Systems FAX (305) 372 -6339 under Chapter 8 of the Metropolitan Dade County Code governing the use of Alternate Materials and Types of Construction, and completely described in the plans, specifications and calculations as submitted by: Dynatech Engineering, Inc., Factory Mutual Research Corporation, and Underwriters Laboratories, Inc. has been recommended for acceptance by the Building Code Compliance Office to be used in Dade County, Florida under the specific conditions set forth on pages 2 -98 and the standard conditions on page 99. This approval shall not be valid after the expiration date stated below. The Building Code Compliance Office reserves the right to secure this product or material at any time from a jobsite or manufacturer's plant for quality control testing. If this product or material fails to perform in the approved manner, the Building Code Compliance Office may revoke, modify, or suspend the use of such product or material immediately. The Building Code Compliance Office reserves the right to revoke this approval, if it is determined by the Building Code Compliance Office that this product or material fails to meet the requirements of the Building Code Compliance Office that this product or material fails to meet the requirements of the South Florida Building Code. aul Rodriguez Product Control Division Supervisor THIS IS THE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL CONDITIONS BUILDING CODE COMMITTEE This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code Compliance Office and approved by the Building Code Committee to be used in D& County, Florida under the conditions set forth above. arles Danger, P.E. af Director Building Code Compliance Dept. Metropolitan Dade County Applicant: GAF Materials Corporation 1361 Alps Road Wayne, NJ 07470 Category: Membrane Roofing System Sub - Category Built -Up Roofing Type: Conventional Sub -Type: Fiberglass PRODUCT CONTROL NOTICE OF ACCEPTANCE ROOFING SYSTEM APPROVAL Product Control No.: 95- 1003.03 Product Control No.: 95- 1003.03 Approval Date: March 14., 1996 Expiration Date: Nov. 10. 1997 System Description GAF Materials Corporation, a manufacturer of commercial roofing products for more than 100 years, produces a wide range of roof products for built -up and modified bitumen roofing systems. In addition, GAF offers two ply modified systems to meet the demands for multi -ply SBS and APP modified specifications. GAF provides warranted systems over various insulated and non - insulated substrates, copies of which can be obtained from GAF and can be found in the "GAFGLAS Built -Up Roofing Application and Specifications" manual published annually. GAF roof system assemblies have been extensively tested at Factory Mutual Research Corporation and Underwriters Laboratories and have been tested in compliance with all requirements of the South Florida Building Code. Specific classifications for assemblies are listed in the current U.L. Roofing Material Directory and the current Factory Mutual Approval Guide. GAF Materials Corporation products are distributed through a wide network of roofing wholesale distributors throughout the South Florida area. For more information on specific roof system constructions, contact the Technical Service Office, located in Wayne, New Jersey, at I- 800 - ROOF -411. Contact: William J. Woodring Director of Technical Services (201) 628 -4134 Frank Zuloaga Plans Examiner, 2 c onto! Division Jnsulation Types: Basalt Wool Perlite Polyisocyanurate Composite Board Wood Fiberboard High Density Wood Fiberboard Rockwool Maximum Design Pressure Material. Design Pressure Wood -60 psf Steel -75 psf Concrete -192 psf Lightweight Concrete -45 psf Cementitious Wood Fiber -45 psf Poured Gypsum Concrete -45 psf Maximum Fire Classification Material Classification Wood Class'A' Steel Class 'A' Concrete Class 'A' Lightweight Concrete Class 'A' Cementitious Wood Fiber Class 'A' Poured Gypsum Concrete Class 'A' Frank Zuloaga Plans Examiner, 3 Product Control No.: 95- 1003.03 Note: Fire classifications and maximum design pressures do not reference all assemblies over all deck types. Review system listings for design pressures and the Underwriters Laboratories Roofing Materials Directory for Fire Classifications. ontrol Division Product Dimensions GAF Materials 5, 55 gallons Corporation Asphalt Concrete Primer GAF Mineral Shield® 60 Ib. bags Granules GAF Materials Corporation Jetblak All Weather Plastic Cement GAF Materials Corporation Plastic Cement . GAF Materials Corporation WeatherCoat® Emulsion GAF Materials Corporation Fibered Aluminum Coating GAF Materials Corporation Jetblak All Weather Plastic Cement GAFGLAS #75® Base Sheet GAFGLAS Ply 4 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT 1, 5 gallons 5 gallons 1, 5 gallons 1, 5 gallons 3' x 108' 75 Ib. roll GAFGLAS Ply 6® 3' x 180' 45 Ib. roll 3' x 180' 40 Ib. roll Test Specification ASTM D 41 ASTM D 1863 ASTM D 3019 ASTM D 3409 ASTM D 2824 Fibered aluminum coating. ASTM D 3019 ASTM D 3409 Frank Zuloaga Plans Examine 4 Product Control No.: 95- 1003.03 Product Description Asphalt concrete primer used to promote adhesion of asphalt in built -up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield® Granules shall be used for flashing applications only. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. 1, 5, 53 gallons ASTM D 4586 Trowel grade, asphalt plastic cement. ASTM 1227 Surface coating for smooth surfaced roofs. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. ASTM D 4601 Asphalt impregnated and coated glass mat base sheet. ASTM D 2178 Type VI asphalt impregnated glass felt with asphalt coating. ASTM D 2178 Type IV asphalt impregnated glass felt with asphalt coatin ontro GAFTITE® #12 Standard Roofing Fastener GAFTITE® #14 Heavy Duty Roofing Fastener GAFTITE® Base Sheet Fastener and Plate insulation. Frank Zuloaga Plans Examiner,Ttrol 5 Product Control No.: 95- 1003.03 Test Product Product Dimensions Specification Description GAFGLAS® 3' x 36' ASTM D 3909 Asphalt coated, glass fiber mat cap sheet Mineral Surfaced 76 lb. roll surfaced with mineral granules. Cap Sheet GAFGLAS® 3' x 36" ASTM D 4897 Fiber glass base sheet impregnated and Stratavent® (Vent 69 Ib. roll D 3672 coated on both sides with asphalt. Ply) for nailable decks Surfaced on the bottom side with mineral granules embedded in asphaltic coating. GAFGLAS® Flashing various Proprietary Asphalt coated glass fiber mat flashing sheet available in three sizes. GAFGLAS® 3' x 36" ASTM D 4897 Fiber glass base sheet impregnated and Stratavent® (Vent 60 lb. roll D 3672 coated on both sides with asphalt. Ply) Perforated Surfaced on the bottom side with mineral granules embedded in asphaltic coating. GAFTEMP® various PA 110 Polyisocyanurate foam insulation. Isotherm . R GAFTEMP® various PA 110 Polyisocyanurate foam insulation with Composite high density fiberboard or Permalite perlite insulation. GAFTEMP® various PA 110 Fiberboard insulation. Fiberboard GAFTEMP® various PA 110 Perlite insulation board. Permalite® GAFTEMP® various PA 110 High density wood fiberboard High Density Fiberboard PA 114 Insulation fastener for steel and plywood decks. PA 114 Insulation fastener for steel, wood and concrete decks. PA 114 Base sheet fastening assembly. 4111# Ruberoid® Mop 1 sq. roll Granule 103 lbs. Vent Stacks (metal and plastic) ASTM D 5147 PA 100(A) ASTM D 1929 ASTM D 635 Frank Zuloaga Plans Examiner, 6 Product Control No.: 95- 1003.03 Test Product Product Dimensions Specification Description Galvalume Plates 3" and 3 'A" PA 114 Round gaivalume stress plates. NTB Fasteners PA 114 Fastener for use in gypsum, tectum and lightweight insulating concrete decks. Polypropylene Plates 3" and 3 %" PA 114 Round polypropylene stress plates. Ruberoid® 20 1.5 sq. roll ASTM D 5147 SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven polyester mat coated with polymer modified asphalt and surfaced with mineral granules. One way valve vent used to relieve built -up pressure within the roof system. GAF Vent Stacks are available in metal or plastic. # ! �T ontrol Division Product Celcore Hy -Therm Nail -line various PA 110 Product Control No.: 95- 1003.03 TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS Test Product Dimensions Specification Description Manufacturer Pyrox various PA 110 Polyisocyanurate foam Apache Products Co. insulation (with current PCA) ACFoam I various PA 110 Polyisocyanurate foam Atlas Energy insulation Products (with current PCA) ACFoam II various PA 110 Polyisocyanurate foam Atlas Energy insulation Products (with current PCA) PA 110 Cellular insulating concrete Celcore, Inc. system (with current PCA) Polyisocyanurate foam Celotex Corp. insulation (with current PCA) Hy -Therm SP various PA 110 Polyisocyanurate foam Celotex Corp. insulation. (with current PCA) Hy -Therm AP various PA 110 Polyisocyanurate foam Celotex Corp. insulation (with current PCA) Hy -Therm Stable R various PA 110 Hy -Therm White various PA 110 Line VaporBar GB 36" x 108' ASTM D 4601 G2 fiberglas base sheet Celotex Corp. (with current PCA) Anchorbond Fastener Dekfast Fasteners #14 Polyisocyanurate foam Celotex Corp. insulation (with current PCA) Polyisocyanurate foam Celotex Corp. insulation (with current PCA) PA 114 Insulation fastening Celotex Corp. assembly (with current PCA) PA 114 Insulation fastener for steel Construction and concrete decks Fasteners Inc. Frank Zuloaga Plans Examine 7 Product Dekfast Hex Plate 2 7/8" x 3 1/4" Dekfast Lock Plate 3" x 3 1/4" PA 114 Dekfast Fasteners #15 Dekfast Fasteners #12 TPR Elastizell FM -30, FM-45, FM -60, FM -90 Fasteners Nail -Tite Type 'A' Nail -Tite Type 'R' ISO 95+ Composite Test Product Dimensions Specification Description PA 114 Galvalume hex stress plate. Construction Fasteners Inc. (with current PCA) PA 114 PA 114 PA 110 PA 114 PA 114 PA 114 PA 110 Polypropylene locking plate. Insulation fasteners for concrete decks Aluminum fastener for lightweight, gypsum and tectum decks Cellular insulating concrete system Base ply fastening systems for lightweight concrete decks 0 Galvanized steel base ply fastener for lightweight concrete decks Galvanized steel base ply fastener for lightweight concrete decks Polyisocyanurate / perlite ridged insulation Frank Zuloaga Plans Examiner, 8 Product Control No.: 95- 1003.03 IOW Manufacturer Construction Fasteners Inc. (with current PCA) Construction Fasteners Inc. (with current PCA) PA 114 Insulation fastener for steel Construction and wood decks. Fasteners Inc. (with current PCA) Creative Construction Components (with current PCA) Elastizell Corp. (with current PCA) ES Products, Inc. (with current PCA) ES Products, Inc. (with current PCA) ES Products, Inc. (with current PCA) Firestone (with current PCA) ontrol Divisio Product Asphalt Asphalt Primer EPS High Density Wood various Fiberboard Oriented Strand various Board Pelite/Urethane various Composite Perlite Insulation Polyethylene Red Rosin Roofing Nails Tin Caps Type X Gypsum various Type X Gypsum various al MB aluminum roof coating Dens -Deck Test Dimensions Specification various Min. 32 ga. x 1 s / various ASTM D 312 ASTM D 41 PA 110 PA 110 PA 110 various PA 110 4 mil min. various Minimum ti PA,I 14 12 PA 121 PA 110 9 Product Description Gypsum insulation board. Product Control No.: 95 1003.03 Manufacturer Type III or IV Hot asphalt generic bitumen adhesive Asphalt Primer generic Extruded polystyrene generic insulation Wood fiber insulation generic board PA 110 Oriented strand board generic Perlite / urethane composite generic board insulation Perlite insulation board generic Vapor barrier / Air barrier generic Rosin paper for barrier generic Layer on wood decks Corrosion resistant annular generic ring shank nails Corrosion resistant circular generic discs. Fire resistant rated gypsum generic Fire resistant rated gypsum generic Aluminum roof coating Grundy Industries (with current PCA) Georgia Pacific Frank Zuloaga _I g Plans Examiner,' o ntrol DLvisl. Product #12 Roofgrip #14 Roofgrip Gripdek Fastener Hexcel Fastener Hextra Standard Plastic Plate ISO 95 +' E'NRG'Y -2 ISORoc N.T.B. Magnum Test Product Dimensions Specification Description Manufacturer various various PA 114 Insulation fastener for steel ITW Buildex or wood decks (with current PCA) PA 114 Insulation fastener steel, ITW Buildex wood or concrete decks (with current PCA) PA 114 PA 114 PA 114 3" round PA 114 PA 110 Insulation fastener Insulation fastener Insulation fastener and metal or plastic plate Polyolefin plastic plate Polyisocyanurate foam / rockwool composite insulation Product Control No.: 95- 1003.03 Frank Zuloaga _■ Plans Examine ntrol Divisio I0 ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) ITW Buildex (with current PCA) various PA 110 Polyisocyanurate foam International insulation Permalite (with current PCA) PA 110 Polyisocyanurate foam NRG Barriers, Inc. insulation (with current PCA) NRG Barriers, Inc. (with current PCA) Con -Tice PA 114 Concrete deck insulation Olympic fastener Manufacturing Group, Inc. (with current PCA) PA 114 Glass reinforced nylon Olympic fastener for use in gypsum Manufacturing and cementitious wood Group, Inc. fiber decks. (with current PCA) Product N.T.B. Spin Weld Plate N.T.B. Plastic Plate 3" round N.T.B. Plate Olympic Standard 3" round Olympic Fastener #14 Olympic Polypropylene Olympic Fastener #12 Olympic Fastener Test Dimensions Specification 2" round PA 114 PA 114 PA 114 PA 114 PA 114 3.25" round PA 114 PA 114 PA 114 Product Description 2" round amorphorus nylon locking plate for use with N.T.B. fasteners with 1" head 3" round polypropylene stress plate for use with N.T.B. fasteners 3" round galvalume AZ55 plate for use with N.T.B. fasteners 3" round galvalume AZ55 steel plate Insulation fastener Polypropylene plastic plate Insulation fastener Insulation fastener Product Control No.: 95- 1003.03 MO Manufacturer Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) Olympic Manufacturing Group, Inc. (with current PCA) `/.-- Frank Zuloaga 411 ■11 Plans Examiner, .. ' ontrol Division 11 Product Olympic CR Base Felt Fastener and Base Sheet Disc GlasFast Fastener GlasFast/Striker Paroc Base Board various Paroc Cap Board various Multi -Max Multi -Max FA UItraGard Test Dimensions Specification various various various Insul -Fixx Fastener Insul -Fixx P 3" round Rawl Drive PA 114 PA 114 PA 114 Insulation fastener Owens- Corning assembly and metal plate Fiberglas Corp. for use over concrete decks (with current PCA) PA 110 Rockwool insulation Partek, Inc. (with current PCA) PA 110 Rockwool insulation Partek, Inc. (with current PCA) PA 110 Polyisocyanurate foam Rmax, Inc. insulation PA 110 Polyisocyanurate foam Rmax, Inc. insulation PA 110 Product Description Insulation fastener assembly for Base Sheet fastening only Insulation fastener assembly with recessed plastic plate Polyisocyanurate foam insulation Product Control No.: 95- 1003.03 Manufacturer Olympic Manufacturing Group, Inc. (with current PCA) Owens- Corning Fiberglas Corp. (with current PCA) (with current PCA) (with current PCA) Schuller International Inc. (with current PCA) PA 114 Insulation fastener for steel SFS /Stadler and wood decks (with current PCA) PA 114 3" round polyethylene SFS /Stadler stress plate (with current PCA) PA 114 Insulation fastener and steel The Rawlplug and plastic stress plate for Company Inc. concrete deck (with current PCA) `/-- Frank Zuloaga 4111 . Plans Examiner, ontrol Drvisi 12 Product Rawl Fasteners #12 Rawl Fasteners #14 Test Dimensions Specification PA 114 Insulation fastener for steel The Rawlplug and wood decks Company Inc. (with current PCA) PA 114 Rawl 2" Plate 2" round PA 114 2" round galvalume AZ55 The Rawlplug membrane plate Company Inc. (with current PCA) Rawl 3" Plate 3" round PA 114 3" round galvalume AZ55 The Rawlplug steel plate Company Inc. (with current PCA) Rawl Spike PA 114 Insulation fastener and steel The Rawlplug and plastic stress plate for Company Inc. concrete deck (with current PCA) Rawlite PA 114 Insulation fastener for The Rawlplug cementitious and gypsum Company Inc. decks (with current PCA) Rawlite 3" Plate 3" round PA 114 3" round galvalume AZ55 The Rawlplug steel plate for use with Company Inc. Rawlite fasteners (with current PCA) 202 HS Super Prep II Tru -Fast DL PA 121 PA 121 Product Description Insulation fastener for use in steel, wood or concrete Roof coating Roof coating Frank Zuloaga Plans Examiner, 13 Product Control No.: 95- 1003.03 Manufacturer The Rawlplug Company Inc. (with current PCA) Thermo - Materials, Inc. (with current PCA) Thermo- Materials, Inc. (with current PCA) PA 114 Insulation fastener for steel, Tru -Fast or wood (with current PCA) ontrol Division Product Tru -Fast Plastic Plate Tru -Fast MP -3 Tru -Fast HD Tru -Fast Ultra Tru -Fast TL Tru -Fast .DP Tru -Fast TP Tru -Fast CF Fasteners Insulcel Structodeck Test Dimensions Specification 3.04" round PA 114 3.23" round PA 114 PA 114 PA 114 PA 114 PA 114 PA 114 PA 114 PA 110 various PA 110 Product Description 3.04" round polyethylene plastic plate 3.23" round galvalume AZ50 steel plate Insulation fastener for use in wood, steel or concrete decks Stainless Steel fastener for use in steel, wood and concrete decks Glass reinforced nylon fastener for use in tectum or gypsum decks Insulation fastener for use in steel or wood decks Insulation fastener for use in steel or wood decks Insulation fastener for concrete decks Cellular insulating concrete system High density wood fiber Frank Zuloaga Plans Examine 14 Product Control No.: 95- 1003.03 Manufacturer Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) Tru -Fast (with current PCA) W.R. Grace (with current PCA) Wood Fiber Industries (with current PCA) 4. "' ontrol Division Test Agency/Identifier Factory Mutual Research Corporation Underwriters Laboratories, Inc. Dynatech Engineering, Inc. Name FMRC 1994 J.I. #0T4A 1.AM J.I. # I V8A4.AM J.I. #1RIA6.AM J.I. #0T2Q4.AM J.I. #0Q6A6.AM J.I. #3X3A2.AM J.I. #0Y9Q5.AM R1306, 87NK11819 3600.02.95 4482.02.95 Test Reports Report Current Insulation Fastening Requirements Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Uplift Approval Class A Fire Classification Wind Uplift, Small Scale Wind Uplift Frank Zuloaga Plans Examiner IS Product Control No.: 95- 1003.03 Mb Date 01.01.94 08.26.92 06.28.93 11.15.91 10.17.91 07.16.91 08.02.94 07.29.94 01.01.93 02.02.95 02.02.95 Deck Type H: Wood, Insulated, New Construction Deck Description: 19 /32 " or greater plywood or wood plank System Type A: Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Insulation Fastener Fastening Fasteners Fastener La gr Type Detail No, Per Board Density (see PA 117) One or more layers of any of the following insulations. Approved Type(s): ACFoam -I, E'NRG'Y 2, GAFTEMP® Isotherm R, E'NRG'Y 2 Plus Minimum: 1" x 3' x 4' N/A N/A N/A N/A Approved Type(s): ISORoc, GAFTEMP® Tapered • Minimum: 1" x 4' x 4' N/A N/A N/A N/A Approved Type(s): Multi -Max Minimum: 1" x 4' x 8' N/A N/A N/A N/A Approved Type(s): High Density Wood Fiber, GAFTEMP® High Density Wood Fiber Minimum:'' " x 4' x 4' N/A N/A N/A N/A Approved Type(s): Wood Fiber, GAFTEMP® Fiberboard Minimum: 1" x 2' x 4' N/A N/A N/A N/A Approved Type(s): Paroc Minimum: %" x 4' x 4' N/A N/A N/A N/A Approved Type(s): Perlite, GAFTEMP® Permalite Minimum: V." x 2' x 4' N/A N/A N/A N/A Approved Type(s): Fiberglas Minimum: ' / x 4' x 4' N/A N/A SYSTEMS Frank Zuloaga Plans Examine 16 Product Control No.: 95- 1003.03 N/A Note: All insulation shall be adhered to the anchor sheet in full moppings of hot asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.. Please refer to Dade County Protocol PA 117 for insulation attachment requirements. N/A Anchor sheet: Base Sheet: PIy Sheet: Cap Sheet: Surfacing: Maximum Design Pressure: Maximum Fire Classification: Maximum Slope: Specification No.: Product Control No.: 95- 1003.03 GAFGLAS® PIy 6 ®, #75 Base Sheet, STRATAVENT® (Vent Ply) for Nailable decks or RUBEROID® 20 base sheet applied to the deck with approved annular ring shank nails and tin caps at a fastener spacing of 12" o.c. at the lap staggered in two rows 12" in the field. Base sheet shall serve as anchor sheet for attachment of insulation. (Optional) Install one ply of GAFGLAS® #75 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs.sq.. If base sheet is applied directly to polyisocyanurate insulation only a spot or strip mopped application as detailed in this approval is approved; see General Limitation #4. One, two, or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. (Required if no cap sheet is used) Install one of the following: -60 psf 1. GAF Special Roofing Bitumen with an application rate of 20 lb./sq.; or Grundy AL MB aluminum Roof Coating with an application rate of 1.5 gal. /sq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. 'A'. See General Limitation #2. 3 ":12 "; See General Limitation #3. I -B -5M, I- B- 5 -M/P6, I- 0 -4 -G, 1- 0- 4- G - /P6, I- 0-4 -C, I- 0- 4 -C /P6, I- 0 -4 -M, 1- 0- 4 -M/P6, [- B-4 -G, I- B- 4 -G /P6, I- B -4 -C, I- B- 4 -C /P6, I- B -4 -M, [- B- 4 -M /P6, I- 0 -3 -G, I- 0 -3 -M, I- B -3 -G, I- B -3 -C, E -0 -3 -C Frank Zuloaga Plans Examiner, 17 ontrol Divisio Wood Deck System Limitations: 4. a. Deck Type: 19 4 2 " Plywood. Product Control No.: 95- 1003.03 1. A red rosin sheet shall be installed on all wood plank decks to eliminate asphalt seepage and bonding of base sheet to plank and deck. Red rosin sheet may also be installed on plywood decks as an option. 2. A slip sheet is required with GAFGLAS® PLY 4 and PLY 6® when used as a mechanically fastened base or anchor sheet. 3. Pre - assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. Pre - assembled 'Cap Nail' shall not be used for base sheet attachment. The following assembly is approved to a maximum design pressure of -52 psf. No substitutions shall be made: b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet, GAFGLAS® Ply 6 ®, or STRATAVENT® (Vent Ply) for nailable decks, or RUBEROID® 20 base sheet. Fastening: Nailed 9" o.c. at the lap and in two rows staggered 18" in the field, nailed with 11 ga. annular ring shank nails and 1s/8" tin caps. c. Insulation: Base Layer: (Optional) Min. 1.2" E'NRG'Y 2, 2 Plus, AC Foam I, II or GAFTEMP Isotherm R adhered to the Anchor Sheet in a full mopping of approved asphalt applied within the EVT range at a rate of 20 -40 lbs. /sq.. Top Layer: Min. Vi" approved wood fiberboard adhered to the base insulation layer in a full mopping of approved asphalt applied within the EVT range at a rate of 20 -40 lbs. /sq.. d. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. e. PIy Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® PIy sheet adhered in a full mopping of approved asphalt applied within the EVT range an Frank Zuloaga Plans Examine 28 f. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. g • Surfacing: (Optional) Install one of the following: Product Control No.: 95- 1003.03 1. GAF Special Roofing Bitumen with an application rate of 20 lb. /sq.; or Grundy AL MB aluminum Roof Coating with an application rate of 1.5 gal./sq.; or GAF WEATHER COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal./sq.. 2. Asphalt flood coat at an application rate of 60 lbsJsq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbsJsq., respectively. The following assembly is approved to a maximum design pressure of -52 psf.* No substitutions shall be made: a. Deck Type: "/ Plywood. b. Anchor Sheet: GAFGLAS® #75 fiberglass reinforced base sheet, GAFGLAS® Ply 6 ®, or STRATAVENT® (Vent Ply) for Nailable decks, or RUBEROID® 20 base sheet. Fastening: 9" o.c. at the lap and in two rows staggered 18" in the field with GAFTITE® insulation screws and steel stress plates. c. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20 -40 lbsJsq.. d. Ply Sheet: (Optional) One, two, or three plies of GAFGLAS® PLY 4 or GAFGLAS® PLY 6® Ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. e. Cap Sheet: One ply of GAFGLAS® Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbs. /sq.. f. Surfacing: (Required if no cap sheet is used) Install one of the following: 1. GAF Special Roofing Bitumen with an application rate of 20 lb./sq.; or Grundy AL M : 1 • • • . ' ' _ with an application rate of 1.5 !... Frank Zuloaga Plans Examine 29 Product Control No.: 95- 1003.03 COAT® Emulsion with an application rate of 3 gal. /sq.; or GAF Fibered Aluminum Coating with an application rate of 1.5 gal. /sq.. 2. Asphalt flood coat at an application rate of 60 lbs. /sq. ± 20 %; plus gravel or slag with an application rate of 400 lbs. /sq. & 300 lbs. /sq., respectively. *Note: The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, corners). No rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners, and corners). Frank Zuloaga Plans Examiner'? ntrol Divisio 30 General Limitations: Frank Zuloaga Plans Examine 97 Product Control No.: 95- 1003.03 1. All asphalt shall comply with ASTM D 312 type III or type IV requirements. All proposed asphalt producers must be approved by the applicant. 2. Fire ratings are determined by a combination of slope, deck type and assembly. Refer to current Underwriters Roofing Materials Directory or other fire testing data listed in the testing file. Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 of the South Florida Building Code. 3. Maximum slope range shall vary for each system; consult current Underwriters Laboratories Roofing Materials Directory and manufacturer's specifications for compliance with design criteria for each project. 4. An overlay /recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet may be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs. /sq.. Note maximum design pressure restrictions on spot attached systems. 5. All work shall be performed by a contractor licensed to do roofing work in Dade County. Contractor shall be familiar with the details and specifications published by the manufacturer. 6. In re- roofing applications, moisture content in an existing roof must be in compliance with Section 3401.10(m), (n) of the South Florida Building Code. 7. Prior to application, all existing roof surfaces used as a bonding substrate shall be tested for uplift resistance in compliance with Dade County Protocol PA 124 to the calculated design pressure of the roof deck. 8. If required, any Factory Mutual Approved vapor barrier in conjunction with proprietary or approved adhesives may be used prior to the application of the insulation layer. 9. Perimeter and corner areas shall have an increase in fastener density for both insulation and base sheet in compliance with Dade County Protocol PA 117 of the South Florida Building Code. 10. All attachment and sizing of perimeter nailers and metal profile designs shall conform with Dade County Protocol PA 111 of the South Florida Building Code. 11. Flashings shall be installed according to the manufacturers standard details, and may be applied in cold application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied modified bitumen membrane. Specific details, approved by the manufacturer, shall be sub Application. Product Control No.: 95- 1003:03 12. Roll good materials shall be stored on end and on a clean, flat and dry surface. 13. Consult current Underwriters Laboratories Directory for the appropriate coating for each roofing assembly to obtain the required fire rating. The assembly shall be installed in strict compliance with Chapter 3401.5 and 3401.6 of the South Florida Building Code for maximum fire classification. 14. Asphalt moppings shall be with applied with asphalt approved by the applicant and shall be approved in compliance with equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and temperature ranges shall be in compliance with Subsection 3403.4(a)(3) of the South Florida Building Code. 15. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20 -40 lbsisq., or mechanically attached using the fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or adhesive. 16. Pre - assembled cap nails may only be used for termination of fully bonded surfaces such as mechanical termination at wood blocking, head and side laps, and base flashing terminations. Cap nails shall not be used for the mechanical attachment of a base sheet. Tin caps are required by the South Florida Building Code. 17. The submission of system specifications and details shall accompany the Section I1 Building Code Permit. This information is available in the publications listed in the 'System Description' of this Product Control Approval. The submission of these documents, as well as the proper application and installation of all materials shall be the sole responsibility of the contractor. 18. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 19. Fastener spacing for insulation attachment is based on a minimum withdrawal resistance value of 275 Ibf. as tested in compliance with PA 105. if the fastener value, as field tested, are below 275 lbf. insulation attachment shall not be acceptable. Frank Zuloaga Plans Examiner,•= f! iv 98 Surfacing: "Gacoflex UA -65 ". applied at 1 gal/ sq. (12 dry mils). 39. Deck: NC Incline: 1 -1/2 Foam: "Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Base Coat: One or two applications ' "Gacoflex UB- 6499 ", applied at 1.2 gal /sq. per applica. tion (14-28 dry mils). Surfacing: "Gacoflex A- 55000 ", applied at 1.1/2 gal/ sq. (14 dry mils). 40. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Top Coat Two Applications "Ure -Cap 68" Series coating (various colors) applied at 1 -3/8 ga , sq /application or 3 applications applied 1-1/4 gal/sq/application. Top Coat (Optional): One application of "Gacoflex UA -65" Series (various colors) applied at ) gal /sq or "Gacoflex UA -60" applied at 1 -1/4 gal /sq (12 dry mils). 41. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly-Iso Special" with "Polyfoam 251" or "Polyfoam 303", 1 in. min. Base Coat One or two applications "Gacoflex UB -64", 1 gal /sq /application (12-24 dry mils), Surfacing: "Gacoflex UA -65" Series 1 gal /sq or "Gacoflex UA -60" applied at 1 -1/4 gal /sq (12 dry mils). 42. Deck: NC Incline: 1/4 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or "Polyfoam 303 ", 1 in. min. Bass Coat One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq /application or 3 applications applied 1 -1/4 gal /sq /application (16 -32 dry mils). Surfacing: "Gacoflex UA-65" Series (various colors) applied 1 gal /sq (12 dry mils). 43. Deck: NC Incline: 1/2 Foam: "Poly -Iso" or "Poly4so Special" with " Polyfoam 251" or "Polyfoam 303 " ", 1 in. min. Base Coat One or two applications "Gacoflex UB- 7050 ", applied at 1 gal /sq/application or 3 applications applied 1 -1/4 gal /sq /application (16 -32 dry mils). Surfacing: "Gacoflex UA -60" Series (various colors) applied 1 gal /sq (15 dry mils). 44. Deck: NC Incline: 2 Foam: "Poly -Iso" or "Poly -Iso Special" with " Polyfoam 251" or " Polyfoam 303 ", 1 in. min. Base Coat "GacoSil S- 1000" applied at 1 gal /sq (10 dry mils). Surfacing: "Gacoflex S- 1000" applied at 1 gal /sq (10 dry mils). 45: Deck: NC Incline: 1 Foam: " Polyfoam 251" or "Polyfoam 303 ", any thickness. Surfacing: "Gacoflex Ure- Shield 7007", 40 dry mils. GAF MATERIALS CORP, WAYNE NJ 07470 R1306 (N) "RUBEROID 20" or "RUBEROID Mod Base 30" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet (" GAFGLAS #75 Base Sheet') is a suitable alternate for Type G 1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with a Type G2 asphalt glass mat base sheet "GAFGLAS Stra- tavent (Vent -Ply) perforated" or " GAFGLAS Stratavent (Vent -Ply) for nailable decks ". Perforated to be mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ( "GAFGLAS #75 Base Sheet" or "GAFGLAS Stratavent (Vent -Ply) for nailable decks') may be subsituted for G 1 asphalt glass fiber ply sheet ( "GAFGLAS Ply 4" or " GAFGLAS Ply 8 ") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. " GAFGLAS Flashing" or "Ruberoid" may be used for flashing in any of the Class A, 8 or C sys- tems listed below. When "perlite" is referenced, this includes "GAFTEMP Perlite" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems list- ed. Structural cement fiber building units are considered suitable to be included as a deck in the fob lowing Class A, B or C systems listed over C -15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2 in. min gypsum board is an acceptable alternate for insulation over C -15/32 decks. The use of polystyrene insulation board between min 3/4 in. perlite board and deck with rosin pa- per (perlite /rosin paper /polystyrene /perlite) is a suitable alternate for isocyanurate board in the fol- lowing Class A, B or C systems. "GAFTEMP Isotherm RA ", " GAFTEMP Tapered Isotherm RA" and "GAFTEMP Composite A" may be substituted for any isocyanurate insulation in any of the following Classifications. Class A, B and C. Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. Class A 1. Deck: C -15/32 Incline: 3 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped. Surfacing: Gravel. 2. Desk: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers Type 01 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Cap Sheet One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". LOOK FOR MARK ON PRODUCT 3 Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood f ibe r, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite. wood fiber /isocyanurate composite, phenolic, 2 in. max. ply Sheet: Two or more layers Type G 1 "GAFGLAS Ply 4" or "GAFGLAS Ply 8 ". Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap Sheet ". 4. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ". 4 in. max, hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. Deck: C -15/32 Incline: 1 Slip Sheet (Optional): Red rosin paper, nailed to deck. Base Sheet: One layer of Type G2 "GAFGLAS #75 Base Sheet" (may be nailed). Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4" or GAFGLAS Ply 8 ". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". peck: NC Incline: 3 Base Sheet One layer of Type G2 "GAFGLAS #75 Base Sheet". ply Sheet:,,One or more layers of Type G 1 "GAFGLAS Ply 4" or GAFGLAS Ply 6". Cap Sheet: One layer of Type G -3 "GAFGLAS Mineral Surfaced Cap Sheet ". Deck: C -15/32 Incline: 2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1.0 in. min (off -set from plywood joints 6 in.). Base Sheet One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus " (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or more layers of Type GI. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus " (granule), "Ruberoid Mop "" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Class B Deck: C -15/32 Incline: 3 -1/2 Insulation (Optionalk One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Two or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6" Cap Sheet Type G3 " GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. 2. Deck: C -15/32 Incline: 3-1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Base Sheet Two or more layers of Type G 1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Cap Sheet "GAFGLAS Mineral Surfaced Cap Sheet ", hot mopped. Class C Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet Three or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Special Roofing Bitumen" 20 Ibs /sq. COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR Class A 1. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite, wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers of Type G1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ", hot mopped with coal tar bitumen. Surfacing: Gravel. COMBINATION HOT AND COLD SYSTEMS Class A 1. Deck: NC Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber or glass fiber, 2 in. max. Ply Sheet: Three or more layers of Type G 1 "GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: Grundy Industries MB Aluminum Roof Coating" at 1-1/2 gal /sq. 2. Deck: NC Incline: 1 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- thane, perlite /isocyanurate composite, perlite /urethane composite. wood fiber /isocyanurate composite, phenolic, any thickness. Ply Sheet: Three or more layers of Type 01 " GAFGLAS Ply 4" or "GAFGLAS Ply 6 ". Surfacing: "Weather Coat Emulsion" at 3 gal /sq. 3. Deck: NC Incline: 1/2 Insulation: One or two layers "Isotherm R ", 4 in., hot mopped. Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber mat system. Class B 1 • Deleted. 2 . Deck: C -15/32 Incline: 2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, ure- 8. 6. 7. 1. 1. LOOK FOR MARK ON PRODUCT OAF MATERIALS CORPORATION 2' Side La -J 28 Bon- Bailable Deck or Acceptable Root Insulation GAFGLAS Base Sheet (sap below) GAFGLAS Ply Approximate Weight per Square Plus weight of insulation and fasteners. GAFGLAS Specifications I-B-4-M/P6, I- 6 -4=M, and NN -G -4-M Roofing Asphalt 2' Side Lap • North, South & West Zones Non - nailable decks or insulated decks up to 6 inches per foot slope. Poured concrete, precast concrete, acceptable roof insulation. Materials GAF Materials Corporation Asphalt/Concrete Primer (when applicable) GAFGLAS Base Sheet GAFGLAS Ply (2 plies) GAF Materials Corporation Roofing Asphalt Interplies Cap Sheet GAFGLAS Mineral Surfaced Cap Sheet (1 pry) 180 -290 lbs.' Guarantees Available S I ecification Libe Guarantees I- B- 4 -M/P6 20,15 yr. I -B-4 -M and NN -B -4 -M 12, 10, 5 yr. Specifications General I in addition to Application recommendations detailed on pages 17 -20 shall apply the following recommendations and specifications. Application of Rooting Membrane 1. Starting at the low point of the root, mop one ply of GAFGLAS Base Sheet, lapping each sheet into place providing for 2 inch side laps and 6 inch end laps. (See "Special Instructions' below.) 2. Starting at the low point of the roof, mop two plies of GAFGLAS Ply shingle fashion; lapping each sheet 19 inches over the preceding sheet; solidly mopped to the underlying base sheet to provide three plies over the entire roof area. Asphalt Requirements Base sheet and interply moppings of Roofing Asphalt must be applied in a continuous film and shall consist of approximately 25 pounds per 100 square feet of roof area with a tolerance not to exceed 20% plus or minus. The appropriate asphalt for the slopes involved must be used. Slope per foot Up to 3° 3 "- 6' Asphalt Type Steep ASTM Type III HT -Steep ASTM Type IV On slopes up to 1 /2 inch per foot, Flat ASTM Type II may be used except in Florida, Texas, New Mexico, Arizona, and California. Surfacing Apply GAFGLAS Mineral Surfaced Cap Sheet in accordance with the application instructions on page 20, so that the laps are offset from the laps of the ply sheets. Special Instructions 1. For roof slopes of 1 inch per foot or more, all plies must be back - nailed 4 inches into wood nailers. See °Installation on Steep Roofs; page 10. 2. Acceptable GAFGLAS Base Sheets include: GAFGLAS STRATAVENT (Vent Ply) Perforated (which is laid dry, i.e., it is not mopped in, see °Venting Systems; beginning on page 53), GAFGLAS #75 Base Sheet, GAFGLAS PLY 6®, and GAFGLAS Ply 4. For insulated decks there are restrictions. See 'Roof Insulation; pages 10 -11. 3. For decks insulated with GAFTEMP Isotherm, GAFGLAS STRATAVENT (Vent Ply) Perforated may be used as the base sheet in place of an overlay board of minimum ' /2 PERMALITE Recover Board or minimum 'A" PERMALITE Insulation. (See "Roof Insulation," pages 10 -11 and the "GAFGLAS STRATAVENT Venting Systems and Construction Details" section beginning on page 53.) UL Classification UL Class A B Substrate _ - Slope _ Insulation C 2° 3A C 31/2 3A UL Chart Key 1. Substrate C = Combustible and Noncombustible Combustible = Wood planks, boards, etc., plywood (min. "In inch thickness), oriented strand board (min.' /2 inch thickness). NC = Noncombustible only Noncombustible = Steel, poured or precast structural concrete, lightweight insulating concrete, gypsum, structural wood fiberboard, etc. 2. Slope Maximum slope allowed, in inches per foot. 3. Insulation 3A = Optional, GAFTEMP PERMALITE ° , Isotherm and Composite (perlite side up) Insulations.