Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-08-1586
Project Address Owner Information Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL 33138 -0000 Phone: (305)795 -2204 Address Contractor(s) Phone CeII Phone KAWALEK ROOFING & PAINTING, INC 786 -277 -9540 (305)754-0191 Fees Due CCF Education Surcharge Notary Fee Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $1.80 $0.60 $5.00 $250.00 $9.00 $8.25 $272.65 Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy Expiration: 03/07/2009 Parcel Number 1099 NE 97 Street Miami Shores Village, FL 1132050170070 Block: Lot: HELEN TRACY HELEN TRACY 1270 NE 95 ST MIAMI SHORES FL 33138 -2550 ,—*rammimaswwwaymm 83:83.3M0333.6 Type of Work: Re Roof Additional Info: FLAT ROOF ON CAR GARAGE Classification: Residential Total Amt Paid I Amt Due $ o.00 $ o.00 $ 0.00 Payment Type: 1EP 12 PAID Phone Applicant Valuation: Total Sq Feet $ 3,000.00 �: - ,..... �N Available Inspections : Cell 0 Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Hot Mop Nailing Affidavit In consideration of the issuance to me of this permit, 1 agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above -named contractor to do the work stated. September 08, 2008 Date Monday, September 8, 2008 1 ck \i I . v Miami Shores Village Building Department BUILDING PERMIT APPLICATION FBC 2004 Permit Type (circle): Building Contractor's Company Name ft Submittal Fee $ Notary $ Scanning $ Bond $ 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 REC V/ EL AU _ 2 8 2008 Electrical Owner's Name (Fee Simple Titleholder) ..E J I! Owner's Address 0-10 g E ah Cit fl f rks - State Tenant/Lessee Name Phone # 10T1 f f C r' Job Address (where the work is being done) City Miami Shores Village County Miami -Dade Zip FOLIO / PARCEL # 1i . � ? OO / '7 o 7 0 Is Building Historically Designated YES NO, awccle, Contractor's Address e. 0 ► Ob y- 6 10 6 l � f City y,� S to C� Zip 53 / 5 3 Qualifier Name OA 1 E co Phone # 84° -' 1 j S 4 State Certificate or Registration No. 6C...4'9 '3 S S ) 3 Certificate of Competency No. 0 b 13-S 0000 / Architect/Engineer's Name (if applicable) Phone # Value of Work For this Permit $ 0- 00 6 -013 ' °as Square / Linear Footage Of Work: 1100 Type of Work: ['Addition , . ['Alteration DNew• Repair/Replace D Demolition Describe Work: * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Zip 33/32 Permit No. r 0 - 1 5$b aster Permit No. Plumbing Mechanical Phone # 3 ✓ 7 ✓® X31'7 Phone# 3 " i - 0/9/ ************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Permit Fee $ CCF $ CO /CC Training/Education Fee $ Technology Fee $ Radon $ DPBR $ Zoning $ Code Enforcement $ Double Fee $ Structural Review. $ Total Fee Now Due $ See Reverse side -* Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address 4 City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that.no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC OWNER'S A14.14 iDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a rei ection fee will be charged Owner ', Agent The foregoing instrument was 'acknowledged before me this day of 4Uu�Ubl , 20 Ot, by tk.w& IQ)ISt - TittL 1 who is personally known to me or who has produced- fl- LiC x \.. As identification and who did take an oath. NOTARY PUBLIC: Sign: Print My Commission Expires: APPLICATION APPROVED BY: (Revised 02/08106) eti' ' ��� ? MONICA LISSETH DIAZ 41° � � % MY COMMISSION # DD 483995 iulQit o ;= EXPIRES: October 20, 2009 h , 4 gg, , Bonded Thru Notary Public Underwriters Signature Contractor The foregoing instrument was t acknowledged before me this z, day of j 206%, , by - ,ut Kite ( l( ( J who is +ersonally . to me or who has produced as iden ,,,,,,,,,,, NOTARY PUBLI�P MY COMMISSION DD 483995 Pe I EXPIRES: October 20, 2009 Bonded Thru Notary Public Underwriters Sign: Print: by My Commission Expires: Plans Examiner Engineer Zoning ROOF ASSEMBUES AND ROOFTOP STRUCTURES Job Address ❑ New Roof • • • • • • ••• •• •• • • • •• •• • • • • • • • • •,• .• • • • ••• • • • • • ••• • • ilk ill Florida Building Code Edition 2004 6h-Velocity Hurricane Zone Uniform Permit Application Form.. • • • • • • • .• • • • • Section A (General Informb.tlolif : • • y� Process] o.• • • •• •••• •• ocr-Pin *. ❑ Prescriptive BUR -RAS 150 /� ROOF TYPE I� Reroofin ❑ Recovering ROOF CATEGORY Ii Low Slope ❑ Mechanically Fastened Tile ❑ Mortar /Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles 0 Wood Shingles/Shakes Shingles ❑ Repair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) I-100 Steep Sloped Roof Area (SF) 0 Total (SF) goo Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. cr d w 0 Cn 15.32 FLORIDA BUILDING CODE =- BUILDING Florida Building Code EIj'tjogn001i• •ROeF . APErt311441111i ROOFTOP STRUCTURES • • ••• • • • • • • • • • • • ••• • • • • ••• •• • • •• •••• • • • • • • • • • • • • • • • • • • • • Section C (Low Slope Application) Surfacing: • • • • • • Fill in specific roof assembly components and identify manufacturer (if a component Is not used, identify as "NA ") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Pmax1: Pmax2: a t z3' r 3 Pmax3: i31; Max. Design Pressure, from the specific Product Approval system: woo Gauge/Thiclmess: T i Deck: Type: Slope: Anchor/Base Sheet & No. of Piy(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of PIy(s): 1 p 4 1.5 B h , - =t ast e = onding anal: c 5 Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: 1W f ' �cdr 1 y M1(�c' 1 Top Ply F ©Tr kn Ir ater FLORIDA BUILDING CODE — BUILDING High - Velocity Hurricane Zone Uniform Per:lit)pph n Fpm.: IW p ? °O5OhO4, Fastener Spactag4or Ancwer/Ba se Shest Attachment • • • Field: • '& L p , • t " o c oc • Perimeter: b "oc @ Lap, # Rows @ b " oc Comer: 4 " oc c Lap, if Rows oc Number of Fasteners Per Insulation Board: Field Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocldng, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit f'FFR M ai�i, f MI,ne- '� FT. ) 1(3 ed v ert six‘se4beitt I FT. Parapet Height i v Mean Roof Height 15.33 1524.1 As it pertains to this section, it is the responsibility of thM•rbe tg catlaet r to'ro■liie the owner with the required roofing permit, and to explain to the owner the content of this section... The provisions of Chapter 15 of the Florida Building Code, Building govern the mirygiyrrL reguireme ;ts NV standards of the industry for roofing system installations. Additionally, the followinNteM de: ddrgssed as part of the agreement between the owner and the contractor. The owner's ;rnitial irk tit adjacknt bolt indicates that the item has been explained. 1. Aesthetics- Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane one) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be enacted in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common Roofs: Common roofs are those which have no visible delineation between �.�hboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or owner should notify the occupants of adjacent units of roofing work to be performed. CO 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and /or deck of the building may not drain well and may e water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not over oaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Code, Plumbing. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the i = rior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be r,. duced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owne • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • • • • • • •••• • • • • • SECTION 1524 • • • • • • • HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTI11CAfIdN Fog WOOFING CONSIDERATIONS &Agent's Signatur, Property Address r / / O/ Date • • • •• • • •••• ••• •••• • • • • • •• • • • • Process Number BUILIMNG CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 This NOA renews NOA 4102- 0408.10 and consists of pages 1 through 31. The submitted documentation was reviewed by Frank Zuloaga, RRC. • • •• •• • • • • • • • • • ••• • • • ••• • • • •• •• • • • • • • P • • ••• • • • 1 • • MIAN%L .bAD€C &U?1TY, FLORIDA METRO -DADS FLAOLER BUILDING • • • GLER rovvr,,surrE 1603 • • • • • SOMA, *LQRI04 331304563 • • . • • • O 3.12901 • SAX 05) 375-2908 •• • • • •• ••• •• • • • • • • • • •• • • • •• • • • • • ••• •• SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHT). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Division (In ATami Dade County) and/or the MU (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material farts to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction BORA reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Division that this product or material fans to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid® Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement "Miami Dade County Product Control Approved ", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatk illy terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number pxeceded by the words M amiDade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. NOA No: 03-0501.02 Expiration Date: .11 / 08 Approval Date:10/23103 Page 1 of 32 ROOFING SYSTEM APPROVAL Category: dub- Category: Deck Tye: MllIWIELatailllaltallln Fire Mica: TRADE NAMES OF PRODUCTS MANUFACTURED 0R LtAB1 S ArPPIAtANT: TABLE 1 Product GAF Asphalt Concrete • Primer (Mat rixTM 307 Primer) GAF Mineral Shield® Granules GAF WeatherCoat® Emulsion (MatrixTM Frbered 305 Emulsion) GAF Premium Fbered Aluminum Roof Coating (MatrixT' System Pro Aluminum Roof Coating Fibered 301) GAF Jetblack All Weather Plastic Cement (MatrixTM Standard Wet/Dry Roof Cement 204) GAFGLAS #75® GAFGLAS #80 UltimaTM Base Sheet GAFGLAS Flex P1yTM 6 GAFGLAS Ply 4® GAFGLAS®M lneral Surfaced Cap Sheet GAFGLAS® STRATAVENT® Eliminator Perforated Roofing SBS/APP, Modified Bitumeb : : Wood 75 psf See General Limitation #1 5, 55 gallons 601b. Bags 1001b. bags 5 gallons 1, 5 gallons 1,5gallons 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37' (1 meter) Wide Test Snedficatiou ASTMD41 ASTM D 1863 ASTM 1227 ASTM D 3019 ASTM D 3409 ASTM D 4.601 ASTM D4601 ASTM D 2178 ASTM D 2178 ASTM D 3909 ASTM D3672 ASTM D 4897 • • . • • • • • • • • • • • • • • •• • • • • • • • • • • • • • • • ••• • • • • • • • • • ••• • • • • • • • • • • • • • • •• • • .• • • . • • • • • • • • . . •.. • • • • • • • • • • • • •. • • • • • .• ••• •• • • Product Desolation Asphalt concrete primer used to promote adhesion of asphalt in built-up roofing. Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mlneral Shield® Granules shall be used for flashing applications only. Surface coating for smooth surfaced roofs. ASTM D 2824 Fbered aluminum coating. Refined asphalt blended with a mineral stabilizer and fibers. Permits adhesion to wet and dry surfaces. Asphalt impregnated and coated glass mat base sheet, Asphalt impregnated and coated, fiberglass base sheet Type VI asphalt impregnated glass felt with asphalt coating. Type IV asphalt impregnated glass felt with asphalt coating. Asphalt coated, glass fiber mat cap sheet surfaced with mineral granules. Fiberglass base sheet coatvd on both sides with asphalt. Surfaced on the bottom side with mineral granules embedded in asphaltic coating with factory perforations. NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 2 of 32 Product GAFGLAS® Flashing GAFGLAS® STRATAVENT® Eliminator Perforated Nailable RUBEROID® SBS Heat - We1dTm Smooth RUBEROID® SBS Heat - We1dT" Granule RUBEROID® SBS Heat Welent 170 FR RUBEROID® SBS Heat - WeldTr PLUS RUBEROID® SBS Heat - Weld PLUS FR RUBEROID Modified Base Sheet RUBEROID® Modified Bitumen Ave RUBEROIl ® SBS Heat - WeldTU 25 Ruberoid® Mop Granule RUBEROID MOP Smooth RUBEROID MOP PLUS RUBEROID MOP 170FR RUBEROID MOP FR RUBEROID TORCH Smooth Dlmensionus various 39.37" (1 meter) Wide 1 meter (39.37") wide 1 meter (39.371 wide 1 meter (39.37") wide 1 meter (39.37') wide 1 meter (39.37") wide 39.37" (1 meter) Wide 5 gallons 1 meter (39.37") wide 39.37" (1 meter) Wide 1 sq. roll 871bs. 39.37" (1 meter) Wide 39.37" (1 Harter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide Test Product S ea tion. • Desc :Asd her et dashing :shbetavailable jn ee�i ASTM D3672' F'bfrglass'Mse u; eet crafted dh both ASTM D 4897 sides with asphalt. Surfaces on the s i ttqanMe ranks itC 4e c - ASTM D -6164 •Nron:Wkrette*Pdyirtts matte with polytror- medified asphalt and smooth surfaced. ASTM D -6164 Non -Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non -Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non-Woven Polyester mat coated with polymer modified asphalt and surfaced with mineral granules. Non-Woven Polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Premium glass fiber reinforced SBS - modified base sheet ASTM D-6164 ASTM D-6164 ASTM D-6164 ASTM D4601, Type 1I, UL Type G2 BUR ASTM D 3019 Type ID ASTM D -6164 ASTM D 6222 ASTM D 5147 ASTM D 6298 ASTM D 5147 ASTM D 6164 ASTM D 5147 ASTM D 6164 ASTMD5147 ASTM D 6164 ASTM D 5147 ASTM D 6222 ASTM D 5147 • • • .. .. .. • ... • • • • • • • • • ... • • • ... • .. • • • • • • • • • • • • • • • • • • • • • ... . Fiber reinforced, rubberized Adhesive Non-Woven Polyester mat coated with polymer- modified asphalt and smooth surfaced. Non woven polyester mat coated with polymer Modified asphalt and surfaced with mineral granules. Non woven polyester mat coated with polymer-modified asphalt and smooth stufaced. Non-woven polyester mat coated with polynnx modified asphalt and surfaced with mineral granules. Non-Woven polyeser mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Non -Woven polyester mat coated with fire retardant polymer modified asphalt and surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt modified bitumen membrane, smooth surface. NOA No: 03.9501.02 Expiration Date: 11/06/08 Approval Date:10123/03 Page 3 of 32 et RUBEROID TORCH Granule RUBEROID TORCH PLUS RUBEROID TORCH FR RUBEROID 170FR TORCH Ruberoid® 20 Ruberoid® 30 Ruberoid® 30 FR RUBEROID® ULTRACLAD® SBS RUBEROID® Dnal FR Vent Stacks (metal and plastic) GAF Aluminum Emulsion GAF Aluminum Roof Paint (MatrixTM System Pro Aluminum Roof Coating Fibered 302) GAF Built-Up Roofing Asphalt RUBEROID MOD Asphalt, Asphalt L & Asphalt P Shingle- Matem Underlayment Tile -Mate Modified Base Sheet Dimensions 39.37" (1 meter) Wide 3937" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 meter) Wide 39.37" (1 miter) Wide 39.37' (1 meter) Wide 39.37' (1 meter) Wide 39.37" (1 meter) Wide 5 gallons 5 gallons 100 lb. cartons, bulk 60 lb. kegs 4 sq. roll 30 lbs. 1.5 sq. roll Test . Product Suedflcatio�4 cr tt n ASTM D 622: ivy Quty, potesteI iu or sed, asphalt ASTM D 514 'Vied b'Umubanen tr014 g}nnule surface. ASTM D 6222 Heavy duty, polyester reinforced, asphalt ASTM D 5147 AMMO biti�mbrira, granule sue ASTM D 6222 •badly Aujytiolyistisseinfaced, coated ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule surface. ASTM D 6222 Heavy duty, polyester reinforced, coated ASTM D 5147 with fire retardant asphalt modified bitumen membrane, granule. surface. ASTM D 6163 SBS modified asphalt base sheet ASTMD 5147 reinforce with a glass fiber mat. ASTM D 6163 Non woven fiberglass mat coated with ASTM D 5147 polymer modified asphalt and surfaced with mineral granules. ASTM D 6298 Non woven fiberglass mat coated with ASTM D 5147 fire retardant, polymer modified asphalt and surfaced with mineral granules.' ASTM D 6163 Woven fiberglass mat coated with ASTM D 5147 Polymer modified asphalt surfaced with aluminum, copper or stainless steel foil. ASTM D 6164 Non-woven polyester and fiberglass mat ASTM D 5147 coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. PA 100(A) One - way valve vent used to relieve built - ASTM D 1929 up pressure within the roof system. ASTM D 635 GAF Vent Stacks are available in metal or plastic. Mineral colloidal bituminous enndsion with reflective aluminum flakes Non- fibered. Aluminum pigmented, asphalt roof coating None ASTM D2824, Type I ASTM D312, TypesI,II,III and IV • .•• • • • • •• • • • • • • • • • • • • • • • .•• • • • • • • • • • • • • • ••• • • • • * • • • • • • • • _ • ••• • • • Interply mopping and surfacing asphalt SEBS modified asphalt Fiberglass reinforced shingle underlayment ASTM D 5147 SBS modified asphalt base sheet and interply sheet reinforce with a glass fiber mat tile underlayment. NOA No: 03.0301.02 Expiration Date: 111 Approval Date:10/23/03 Page 4 of 32 Product Tile -Mate Modified Cap Tile -Mate Modified Cap Plus Topcoat® Surface Seal SB (Matrix 602 SB Coating) GAF WeatherCote® MB+(Matrix 715 MB Coating) TopCoat MB+(Matrix 715 MB Coating) WeatherCoteTM (Matrix 531 WeatherCote® Elastomeric Flashing Grade) Matrix Low VOC Matrix 101 System Pro SBS Adhesive (Ruberoid ®MB) Matrix 201 System Pro SBS Flashing (Ruberoid ®MB) Matrix 102 Select SBS Adhesive (Ruberoid ®MB) Matrix 202 Select SBS Flashing Matrix 203 Standard Plastic Cement Matrix 213 Gun Grade Plastic Cement Matrix 103 Cold Adhesive Matrix 303 Select Fibered Aluminum Matrix 304 Select Non - Fibered RUBEROID® Modified Bitumen Adhesive 1 sq. roll 1031bs. 1 sq. roll 102 lbs. 5 gallons 5 gallons 5 gallons 5 gallons Test Product do Descrintion ASTM D 5147 pit o/wren gabiestej I tcoated with :P2Aner ittediftect asA • with mindiggraules tilt umderlayment ASTM D 5147 Non -woven polyester mat coated with 5 gallons 5 gallons ASTM D3019 5 gallons ASTM D3019 5 gallons ASTM D3019 5 gallons ASTM D4586 5 gallons ASTM D4586 5 gallons ASTM D4586 5 gallons ASTM D3019 5 gallons ASTMD 2824 5 gallons ASTM D2824, Type I 5 gallons ASTM D 3019 Type /II • • • •• • • • ••• •. •• • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • • • • • ••• • • • • ••• .rogypur Vilifiect o arm: 8"d surfaced *4 6:an aj iAtiblVtilettildeliaYment • • • • . • • • • • Surface coat for ::41 surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Surface coating for smooth surfaced and mineral surfaced roofs. Cold Applied Modified SEBS Asphalt Adhesive Cold Applied Modified SEES Asphalt Adhesive —Flashing Grade. Cold Applied Modified SEBS Asphalt Adhesive. Cold Applied Modified SEBS Asphalt Adhesive — Flashing Grade. Standard Plastic Asphalt Roofing Cement Standard Plastic Asphalt Roofing Cement caulk Grade. Cold Applied Asphalt Adhesive. Piberel aluminum coating. Non -fiber. Aluminum pigmented, asphalt roof coating. Fiber reinforced, rubberized Adhesive NOA No: 03.0501.02 Expiration Date: 11/06108 Approval Date:10/23/03 Page5of32 APPROVED INSULATIONS: Product Name GAFTEMP Isotherm R, RA, RN & Composite, EnergyGuard RA GAFTBMP® Composite A & N •(BMCA)GAFTEMP® Fiberboard GAFTEMP® Permalite GAFTEMP GAFCANTTM GAPTEMP Permalite Recover Board GAFIB P GAFEDGETm Tapered Edge Strip (BMCA) GAFTEMP® High Density Fiberboard BMCA EnergyGuard, RA BMCA Composite EnergyGnard, RA PYROX White Line ACFoamI, II & Composite ISO 95+ ISO 95+ Composite EPS Wood Fiber High Density Wood Fiberboard PelitelUrethane Composite Perlite Insulation Dens Deck E'NRG'Y-2 & E'NRG'Y 2 PLUS, UltraGard Gold • • • • • • • • • • TABLE 2 • .. • •••• • • Product Description •••• Polyisocyanurate foam insulation... • •. Polyisocyanurate foam insulation with • high density fiberboard or Permaliite perlite insulation. Fiberboard insulation. Perlite insulation board. Cut perlite board Perlite recover board Tapered perlite board High density wood fiberboard insulation. Polyisocynurate foam insulation Polyisocynurate/wood fiberboard composite Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanuiate/perlite ridged insulation Extruded polystyrene insulation Wood fiber insulation board Wood fiber insulation board Perlite / urethane composite board insulation Perlite insulation board Water resistant gypsum board Polyisocyanurate foam insulation • • ••• • •• •• • • • • • • • . • • • • ••• • • • • • • • ••• • • • •• • • • • • • • • • • •• • • • • • • • • • • • • •. ••• • •••. • . . • • ••• • •• •• • • • • • • • • • • • • • ••• • Manufacturer (With Current NOA) 4AVIalarals Corp. • • • CIAF Matdnals Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. GAP Materials Corp. BMCA BMCA Apache Products Co. Apache Products Co. Atlas Energy Products Firestone Building Products, Inc. Firestone Building Products, Inc. Generic Generic Generic Generic generic G-P Gypsum Corp. Johns Manville NOA No: 03-0501.02 Expiration Date: 11/06/08 Approval Date :10/23/03 Page 6 of 32 APPROVED INSULATIONS: Product Name FiberGlass Roof Insulation ISORoc Structodek Multi-Max & FA Paroc Base Board Paroc Cap Board APPROVED FASTENERS: Fastener Product Number Name 1. GAFtTTE® (Drill -Teel)) #12 Standard & #14 Heavy Duty Roofing Fastener 2. GAFTITE® (Drill -Tec®) ASAP 3. GAIITITE® (Drill-Tec®) Base Sheet Fastener and Plate 4. Gaivalume Plates (Drill Tec® Metal) 5. Polypropylene Plates (Drill -Teel) Plastic) 6. Dekfast Fasteners #12, #14 & #15 7. Dekfast Hex Plate 8. Dekfast Lock Plate 9. #12 Roofgrip Fasteners 10. Metal Plate 11. Gearlok Plastic Plate 12. Glasfast Fastener TABLE 2 6 ' . . . Product Description • • Glass fiber/Mmeral fiber insulation • • • • Insulation fastener assembly with recessed plastic plate • Polyisocyanurate foam / rock*oot • composite insulation Wood fiber insulation board Polyisocyanurate roof insulation Rockwool insulation • . • • TABLE 3 Product Description Dimeredmm Insulation fastener for steel, wood & concrete decks. ' Pre - assembled GAM ITE Fasteners and metal and plastic plates. Base sheet fastening assembly. Round galvalume stress plates. Round polypropylene stress plates. Insulation fastener for wood, steel and concrete decks Galvelume hex stress plate. 2 7/8" x 3 3 "x3/4" Polypropylene locking plate. Insulation fastener for wood and steeL Galvalume stress plate. 3" round 3" square Polypropylene round plate 3.2" • • ••• • • • • • • • • • . • • • • • '•' • • • • • • • • • • • • • • • • • • • • • • • • • • • ... • • • ••• .. . . ... •••. ... (With Cdrrent NOA) Johns Manville • •• ••• •• Jars Manville • • • • • • • • ••• Masonite. RMax, Inc. Partek, Inc. Manufacturer (With Current NOA) GAF Materials Corp. GAF Materials Corp. GAF Materials Corp. 3" and 3 1/2" GAF Materials Corp. 3" and 3 1" GAF Materials Corp. Construction Fasteners Inc Construction Fasteners Inc. Construction Fasteners Inc. 1TW Buildex Corp. 1TW Buildex Corp. IT W Buildex Corp. Johns Manville NOA No: 034501.02 Expiration Date: 11/ Approval Date :10123/03 Page 7 of 32 APPROVED FASTENERS: Fastener Number Product Name 13. Olympic Fastener 4t12 & #14 14. Olympic Fastener ASAP 15. Olympic Polypropylene 16. Olympic G-2 17. Olympic Standard 18. Insul Fixx Fastener 19. Insul -Fist S Plate 20. Insul-Fixx P Plate 21. Tru-Fast 22. TruFast Plates 23. Tru -Fast Plates EVIDENCE SUBM TIED: Description Insulation fastener Pre - assembled Insulation . fastener and plate Polypropylene plastic plate 3.5" round galvalume AZ55 steel plate 3" round galvalume AZ50 steel plate Insulation fastener for steel and wood decks 3" round galvalume AZ50 steel plate 3" round polyethylene stress plate Insulation fastener for steel and wood decks 3" round galvalwxic AZ55 steel plate Polyethylene plastic plate Tes Asencv Test Identifier TABLE 3 • • Product • • • Factory Mutual Research Corp. Current Insulation Attachment Requirements Factory Mutual Research Corp. FMRC 4470: PA 114 Trinity Engineering Wind Uplift PA 114 PRI Asphalt Technologies, Inc. IRT of S. F1. IRT of S. FL GAF-020 -02-01 02-005 02.014 • • ••• • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • ••• • • • • • •. • • • • • • ... • • • • •••. .• • • • • • • • . cturer • Dimensions "(With tun'hnt NOA) • • • • A • • Gfqup, Inc. • • "Ai is Manufacturing Group, Inc. 3.25" round Olympic Manufacturing Group, Inc. 3.5" round Olympic Manufacturing Group, Inc. 3 " round Olympic Manufacturing Group, Inc. SFS /Stadler •• 3 " round 3" round 3 " round 3" round • • ••• •• •• • • • • • • • • • • • • • • ••• SFS/Stadler SFS/Stadler The Tru-Fast Corp. The Trn Fast Corp. The Tni-Fast Corp. lineage. ilatt FMRC 1996 01.01.96 J.I.1B9A8.AM 09.04.97 J.I. 3D4Q2.AM 04.30.97 4483.04 97 -1 06.06.97 ASTM D 4977 02.01.02 TAS 114 01.18.02 TAS 114 03.22.02 NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 8 of 32 Faroe, Perlite, GAFTEMP® Fermalite Minimum 3/4" thick Fiberglas Minimum 15 / 1 6" thick • • ••• • • •• •• • • • • •• •• '•' • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • ••• • • • • • ••• APPROVED ASSEMBLIES •' • ••• •• • • • • • • • • •• • • ' •• • • • • ••• Membrane Type: SBS ... • • � • • • • Deck Type 1I: Wood, Insulated • • • • • • • • • • Deck Description: 19 / 32 " or greater plywood or wood plank System Type A (1): Anchor sheet mechanically fastened, alllay vfinsul16onnd with approved asphalt. • •' ' • MI General and System Limitations • shall apply. • • • • • • • • •• One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft ACFoam I, ENRGY 2, GAFTEMP® Isotherm R, ENRGY 2 Ifs, GAFTEMP Isotherm RA, GAFTEMP Isotherm RN, GAFTEMP Composite, GAFF Composite A, GAFTEMP Composite N, ISORoc, BMCA EnergyGnard, BMCA EnergyGuard Composite, EnergyGard ISO, EnergyGuard RA Composite, EnergyGuard RA Minimmm 1" thick N/A N/A Wood Fiber, GAFTEMP® Fiberboard, BCMA High Deusity Wood Fiber, GAFTEMP® EMP® High Density Wood Fiber, GAFTEMP Recover Board Minimum Vs" thick N/A N/A N/A N/A N/A N/A Note: All insulation shall be adhered to the anchor sheet in, fall mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft Please refer to Roofing Application Standard RAS 117 for insulation attachment Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation instated as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polylsocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® Eliminator Perforated land dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Anchor sheet GAFGLAS #80 Ultimami Base Sheet, STRATAVENT® Eliminator Perforated Nailable Base Sheet, RUBEROID Modified Base Shy, RUBEROID® 20, RUBEROID SBS Heat We1dTa Smooth or RUBEROID SBS Heat Weld 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4®, GAFGLAS Flex P1yT d 6, GAFGLAS #75 Base Sheet or any Options: of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure -45 psf, See General Jimitatdon #7) GAFGLAS® Ply 4®, GAFGLAS Flex PIyTm 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill Tec (GAFI ITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) NOA No: 03.0501.02 Expiration Date: 11 Approval Date:10123/03 Page9of32 GAFGLAS Flex P1yma 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved Rapt sing shank nai $ and tin cads at a fastener spacing of 9" o.c. at the 4" lap reaggired and mlw2 ,routs r p.a 3a the field. (Maximwn Design Pressure 52 ► ; $Ve G.j quJ Anittlidli GAFGLAS #75 Base Sheet or any of above Anchor sheets attached'to desk with Drill Tec (GAFiUE) #12 or #14 Screws aid 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows eg egly.fshcsdapPkintitely 9" o.c. in the field of the sheet. • • • • • • • • (Maximum Design Pressure - 60pee, See iendraYLuiaitdtkni • • Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tee (GAFTITE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Marina= Design Pressure -60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -75 psf, See General Limitation #7) Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 ULTIMATA Base Sheet, GAFGLAS® PLY 4®, GAFGLAS Flex P1yTA 6, GAFGLAS STRATAVENT Eliminator Perforated (laid dry), RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat Welem Smith or RUBEROID SBS Heat-Weld 25 directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsisq (see General Limitation #4). Ply Sheet (Optional) One or more plies GAFGLAS PLY 4®, GAFGLAS Flex Ply 6 sheet, GAFGLAS #80, RUBEROID MOP Smooth, RUBEROID® 20 adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs.sq. Membrane: One or more plies of RUBEROID® 20, RUBEROID 30, RUBEROID 30 FR RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, RUBEROID MOP PLUS, RUBEROID MOP FR, RUBEROID ULTRACLAD ®, or RUBEROID Dual FR fully adhered in an approved asphalt at an application rate of 25 lb./sq. * 15%. Surfadng: (Optional, requited if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lb./sq. ± 15%. 3. GAF Weatlercote® MB+(Matrix 715 MB Coating), Applied at 1 to 1.5 gal./sq. 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 13 gaUsl• Maximum Design Pressure: See Fastening above. • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • • • • • ••• • • • • • • ••• NOA No: 03.0501.02 Expiration Date: 11/06/00 Approval Date:10/23103 Page10of32 Membrane Type: Deck Type 1I: Deck Description: System Type A (1): • • � ••• • • • • • • Wood, Insulated • • • • • • • • • • • 'g / or greater plywood or wood plabr . •, • : .. • • Anchor sheet mechanically fastened, all layers of insulation approved asphalt. All General and System Limitations shall apply. • APP /SBS Heat Weld • • •• •• • • • • • • • • • • •• • • • •• ••• •• • ••• ••• •• •• ••• • • • • • • • • ••• • • • • • • • • • ••• • • • • ••• • • • • •••• adhered with • • • • • • • • One or more layers of any of the following insulations. • • • • • • • ••• • • Insulation Layer Insulation Fasteners Fastener (Table 3) Density/& ACFoam I, ENRGY 2, GAFTEMP® Isotherm R, ENRGY 2 Plus, GAS' Isotherm RA, GAFTEMP Isotherm RN, GAFTEMP Composite, GAFTEMP Composite A, GAFTEMP Composite N, ISORoc, GAFTEMP® Tapered, BMCA EnergyGuard, BMCA EnergyGuard Composite, EnergyGuard RA, EnergyGuard RA Composite Minimum 1" thick N/A N/A Wood Fiber, GAFTEMP® Fiberboard, High Density Wood Fiber, GAFTEMP® High Density Wood Fiber, GAFTEMP Recoverlloard Minimum 1/2" thick N/A N/A Faroe, Periite, GAFTEMP® Permalite Minimum Vs" thick • N/A N/A Fiberglas Minimum %" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in fall mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft Please refer to Rooms Application Standard RAS 117 for insulation attachment, Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS STRATAVENT® Eliminator perforated laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Anchor sheet GAFGLAS #80 UltimaT" Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBBROJD® 20, RUBBROID SBS Heat We1dTM Smooth or RUBEROID SBS Heat Weld 25 base suet meclanic ally fastened to deck as described. below; Fastening GAFGLAS® Ply 4®, GAFGLAS Flex P1y 6, GAFGLAS #75 Base Sheet or any Options: of above Anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure - 45psf, See General Limitation #7) GAFGLAS® Ply 4 ®, GAFGLAS Flex P1yTM 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Tec (GAFI dTE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure -45 psf, See General Limitation #7) NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Pee 11 of 32 GAFGLAS Flex P1y 6, GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with approved annular ring shank naiksand tip caps at a fastener spacing of 9" o.c. at the 4" lap stagsemil•an m tyvglows 9' cCc.°m'the field. (Maximum Design Pressure -52..iptf,Ver Gearal Z /La Son#1 GAFGLAS #75 Base Sheet or any of abovd Anchor shaifs attached to deck with Drill -Tee (GATITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows ar .equa,41 spatgd:tpprtnitnatLFy 9" o.c. in the field of the sheet. • • • (Maximum Design Pressure -- 60psf, See Guard l ' ita • • • • ' Any of above Anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec (GAFTTTE) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure -60 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Anchor sheets attached to deck with Drill-Tec (GAME) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure 75 psf, See General Limitation #7) Base Sheet: install one ply of GAFGLAS® #75, GAFGLAS #80 ULTIMATm Base Sheet, GAFGLAS® PLY 4®, GAFGLAS Flex Ply" 6, GAFGLAS STRATAVENT Eliminator Perforated (laid dry), RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat We1dTM Smooth or RUBEROID SBS Heat-Weld 25 directly over the top layer of insulation Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq (see General Limitation #4). Ply Sheet: (Optional except over RUBEROID Modified Base Sheet, RUBEROID MOP Smooth, RUBEROID® 20, RUBEROID SBS Heat-Weld'' Smooth or RUBEROID SBS Heat-Weld) One or more plies GAFGLAS PLY 4®, GAFGLAS® PLY 6® Ply or GAFGLAS Flex Ply 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. or Ruberoid Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of Ruberoid® Torch Smooth, Ruberoid® Torch Granule, Ruberoid® Torch Plus Granule or Ruberoid® Torch FR torch applied according to manufacturer's application instructions. Or One or more plies of RUBEROID® SBS Heat We1dni PLUS, RUBEROID® SBS Heat Weldna PLUS FR, RUBBROID® SBS Heat We1drm 170 FR, RUBEROID® SBS Heat-Weld, RUBEROID® SBS Heat We1dTm Smooth, RUBEROODO U1traCladni SBS and RUBEROID® SBS Heat-Weld nit 25 applied according to manufacturer's application instructions. Surfacing: (Optional) Install one of the following. L Gravel or slag applied at 400 lb./sq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 60 lb./sq. 2. GAF Premium Fibered Aluminum Roof Coating, at 1.5 gal. /sq. or GAF WeatherCoat Emulsion at 3 gal/sq. (Torch Smooth applications only) 3. GAF Weathercote® MB+(Matrix 715 MB Coating), Applied at 1 to 1.5 rsq• • . •• • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • • ••• • NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 12 of 32 4. Top Coat® Surface Seal SB{Matrix 602 SB • • • • • • • Casting }, Applied at 1 to 1.5 gal./sq. Maximunn Design Pressure: See Fastening Above •' • • ' • ' • " • • • • • • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • •l• • • • • • • •• • • • ••• •• • • • • • •• •• • • • • • • • • • • • • • • ••• • • • • • • • • • • • •• • • • •• 111 •• • • • • • • • • •• • • • • • •IS •. NOA No: 03- 0501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page 13of32 Membrane Type: SBS • • ••• •. •• • • • • • • • • • • • • • . • • • • .•• • • •• .• • • • • • • • .•• • • • • • • • • •.• • Deck Type lI: Wood, Insulated • • • • •• • • •• • • • • • • • • • •• • • • •• • • • Deck Description: ' or greater plywood or wood plank • • . • • . • • • • • • ' • System Type B: Optional base sheet laid dry; base layer of inJlatioo mechanical, fastened, optional top layer adhered with approved atbalC . • • • • • Ml General and System Lhnitatlons shall apply. • • • • • • • • `• • • One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft ACFoam -I, EnergyGuard RA Minimum 1.3" thick 1, 2, 6, 9,13 or 14 1:3 ft ENRGY 2, GAFTEMP Isotherm RN Minimum 1.4" thick 1, 2, 6, 9,13,14 or 21 1:3 ft GAFTEMP® Isotherm R, BMCA EnergyGuard Minimum 13" thick 1, 2, 6, 9,13,14 or 21 1:3 ft ENRGY 2 Phis, GAFTEMP Composite N, BMCA CompositeEnergyGuard Minimum 1.5" thick 6, 9,18 or 21 1:3 ft Perlite, GAS® PERMAALITE Minimum 2 /" thick 1, 6, 9,13or 21 1:2 ft Fiberglas I$ /:6" thick 1, 2, 6, 9, 12, 13, 14, 18 or 1:2.67 ft 21 Wood Fiber, GAFTEMP® Fiberboard, GAFTEMP High Density Fiberboard M Minimum 1" thick 1, 2, 6,13,14 or 21 1:2 ft Note: Base layers of Insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sbes and dons; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tail for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for won attachment. GAF requires either a ply of GAFGLAS STRATAVENT® E�ator perforated laid dry or a layer of GAS® PEERMA.LITE or wood fiber overlay board on all isocyannrate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/11 Any of the insulation listed for Base Layer, above. High Deity Wood Fiber, GAFTENIP® High Density Wood Fiber, GAFTEMP RecoverBoard Minimum V2 thick N/A N/A Paroc Minimum Vit" thick N/A N/A NOA No: 03- 0501.02 Expiration Date: 11/06108 Approval Date:10/23103 Page 14 of 32 Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20.40 lbs/l00 ftz. • Please refer to Roofing Aeplicatign Stppdard J AS.117 for insulation attachment. Composite insulation boards used as i ppjayef l Da instable% wig the polyisocyanurate face down. • • • • • • • • • ••• • • • Base Sheet: (Optional) Install one ply of GAFGLAS® #75, GAFGLAS #80 ULTIMA Base Sheet, GAFGLAS® PLY 4 ®, GAFGLAS® PhY,61:4), GAPGLASFIex PI? 6, GAFGLAS STRATAVENT Eliminator P. • s •. • ),RRCEIt.0)D Modified Base Sheet, RUBEROID MOP Smocih'oriR ^ : :4' • , �;30 ilittctly over the top layer of insulation. Adhere wit any ° approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbsjsq; (see General Limitation #4). Ply Sheet (Optional) One or more plies GAFGLAS PLY 40, GAFGLAS Flex Ply 6 sheet or GAFGLAS #80 Ultima adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs.sq. Membrane: One or more plies of RUBEROID® 20, RUBEROID 30, RUBEROID 30 FR RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, RUBEROID MOP PLUS, RUBEROID MOP FR, RUBEROID Dual FR or RUBEROID ULTRACLAD®, fully adhered in an approved asphalt at an application rate of 25 lb./sq. ± 15 %. Surfacing: (Optional, required if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lbisq. and 300 lb./sq. respectively in a flood coat of approved asphalt at 6011x/sq. 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 2511x/sq. ± 15%. 3. GAF Weathercote® MBA- (Matrix 715 MB Coating), Applied at 1 to 1.5 galfsq. 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 1.5 gausq.. Maximum Design Prenure: • -45 psf; (See General Limitation #7) • • ••• • • • ••• •• •• • • • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • ••• • • • • •_• NOA No: 03- 0501.02 Expiration Date: 11 Approval Date:10/23/03 Pap 13 of 32 Membrane Type: Deck Type lI: Deck Description: System Type B: ACFoani I, EnergyGuard RA Minimum 1.3" thick APP /SBS Heat Weld Wood, Insulated ENRGY 2, GAFTEMP Isotherm RN Minimum 1.4" thick • • • •• 19 / 32 " or greater plywood or wood plank GAFTEMP® Isotherm R, BMCA EnergyGuard Minimum 13" thick • • ••• • • • ... . . . • • • • .• . • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • .. • • • • •• • • •. • • • • ... .. • • • • • • . . . • • • • • • • • • • • •• .. • ••• • • • Optional base sheet laid dry; base layer of insulation liPecttiwic411% fas ned, optional top layer adhered with approved as$hA All General and System Limitations shall . apply. One or more layers of any of the following insulations. Base Insulation Layer •• • • • • • . • • • . •. • Insulation Fasteners Fastener (Table 3) Density/& 1,2,6,9,13or14 1:3ft 1, 2, 6, 9, 13, 14 or 21 1:3ft 1,2,6,9,13, 14,18or21 1:3ft ENRGY 2 Plus, GAFTEMP Campsite N, BMCA Composite RuergyGuard, EnergyGuard RA Composite Minimum 1.5" thick 6, 9,18 or 21 Fiberglas Minimum 13/16" thick 21 1:3 ft Perlfte, GAS® PERMALITE Minimum 3/4" thick 1, 6, 9,13 or 21 1:2 ftz 1, 2, 6, 9, 12, 13, 14, 18 or 1:2.67ft Wood Fiber, GAS® Fiberboard, GAFTEMP High Density Fiberboard Minimum 1" thick 1, 2, 6,13,14 or 21 1:2 ftz Note: Base layers of fnsolation shall 1* mechanically attached using the fastener density listed. The insulation panels listed are mfnimuin sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment.. GAF requires either a ply of GAFGLAS STRATAVENT® Eliminator perforated laid dry or a layer of GAFTEMP® PERMALITE or wood fiber overlay board on all isocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/& Any of the insulation listed for Base Layer, above. High Density Wood Fiber, GAFTEMMP® High Density Wood Fiber, GAFTEMP Recover Board Minimum 'h" thick N/A N/A Paroc Minimum 9 /a" thick N/A N/A NOA No: 03- 0501.02 Expiration Data 11/0 Approval Date:10123/03 Page 16of32 Membrane Type: Deck Type 1: Deck Dtscriptlon: System Type E ( All General and System Limitations shall apply. Base sheet: Fastening Options: Ply Sheen SBS /SBS Cold Applied Wood, Nan- insulated 19 / 32 " or greater plywood or wood plank decks • • ••• • • • ••• • • • • • • • •• •• • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • ••• • • • • ••• • • • • • • •••• •• •••• • • • • ••• ••• • • • • • • •• • • • • • • •• •••• • • • •• • • • .. • • • •• ••• •• Base sheet mechanically fastened to roof kak.. • • . • • • • • •• • • • • • • • • GAFGLAS #80 UltimaTM Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID® 20, RUBEROID SBS Heat We1dTM Smooth or RUBEROID SBS Heat Weld 25 base sheet mechanically fastened to deck as described below; GAFGLAS® Ply 4®, GAFGLAS Fiex P1yTM 6, GAPGLAS #75 Base Sheet or any of above Base sheets attach to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" oc. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General In #7) GAFGLAS® Ply 4®, GAFGLAS Flex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows, One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet (Maxinunn Design Pure —45 psf, See General Limitation #7) GAFGLAS Fiex PIyTM 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" oc. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure 52.3 psf, See General Limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets awaked to deck with Drill Tee (GAPTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced apprnximately 9" o.c. in the field of the sheet. (Maximum Design Pressure --60 psj; See General limitation 17) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec (GAFT1113) insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure — 60 psf, See General limitation #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drill Tec (GAFIITE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure 75 psf, See General Lion (Optional) One or more plies GAFGLAS PLY 4®, GAFGLAS Flex Ply 6, GAFGLAS #80, RUBEROID MOP Smooth or RUBEROID 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40lbsfsq. NOA No: 030801.02 Expiration Date: 11/06/08 Approval Date:10R3103 Page 26 of32 Membrane Type: SBS/SBS Cold Applied Deck Type 1: Wood, Non - insulated • • ••. • • • • . • • • • • • • • • • • • • • • • • • • • • • • • • • .•• • • • • • • • • • • • • • • • • • • ••• Deck Description: 14/32" or greater plywood or wood plank decks • System Type E (1): Base sheet mechanically fastened to roof dell. • • • • • • •. • • • • • • • . . . • • • • • • • • • •• • • . • • • ••. • • • •.•• • . . . • .•• • . • . • • • • •• •• • • • • • Ml General and System Limitations shall apply. • • • • • • • ••• • • • Base sheet GAFGLAS #80 UltimaTm Base Sheet, STRATAVENT® Eliminator Perforated Nailable, RUBEROID Modified Base Sheet, RUBEROID® 20, RUBEROID SBS Heat We1dTl Smooth or RUBEROID SBS Heat Weld 25 base sheet mechanically fastened to deck as described below; Fastening GAFGLAS® Ply 4®, GAFGLAS Flex Flynt 6, GAFGLAS #75 Base Sheet or any Options: of above Base sleets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" oc. at the lap staggered and in two rows 12" o.c. in the field (Maximum Design Premiere -- 45psf, See General Limitation #7) GAFGLAS® Ply 4®, GAFGLAS Flex Flynt 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with Drif Tec (GAPTITB) #12 or #14 Screws and 3" Plates, 12" o.c. in 3 rows. One row is in the 2" ride lap. The other rows are wally spaced approximately 12" o.c. In the Sell of the sheer (Maxine m Design Pressure -45 psf, See General, imitation GAFGLAS Flex P1y'm 6, GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure -52.5 psf, See General Lion #7) GAFGLAS #75 Base Sheet or any of above Base sheets attached to deck with DrjIl Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure -10 p4 See Geenoal Limitation #7) Any of above Base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec (GAFTITE) insulation plates at a fastener' spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure - 60 psf, See General Limitation #7) GAFGLAS #75 Base Shy or any of above Base sheets attached to deck with Drill-Tec (GAFTITE) #12 or #14 Screws and 3" Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Prime -75 psf, See General limitation #7) Ply Sheet: (Optional) One or mare plies GAFGLAS PLY 4®, GAFGLAS Flex Ply 6, GAFGLAS #80, RUBEROID MOP Smooth or RUBEROID 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 40 lbs./sq. NOA No: 034501.02 Expiration Date; 11/06/08 Approval Date:10/ Page 26 of 32 Membrane: One or more plies of RUBEROID MOP Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, Ruberoid® Noy Plus Granule, Ruberoid® 2Q, Ruberoid® 30 or Ruberoid® 30 FR or4buLd® oral:3 333M D UltmCladng SBS in adhered in a full dmiSpiturof agarpve4 sspha1 sppliled within the EVT range and at a rate of 20- 40lbssq. Or, One or more plies of RUBEROID MOP SilolltinfitElibIliVh4413ranule, RUBEROID® Mop 170 PR, RUBEROID@ P[u ;GuqulI, Ruberoid® 20, RUBEROID® 30, RUBEROID® 30 FRC} R17B'ER ©II)® MepFR'er RUBEROID U1traCladut SBS in RUBEROID Modified Bitumen Adhesive at an application rate of 1-2 galisq. Surfacing: (Optional, r if RUBEROID MOP Smooth or RUBEROID 20 is top membrane) Install one of the following: 1. Gravel or slag applied at 400 lb./sq. and 3001b/sq. respectively in a flood coact of approved asphalt at 60 lb./sq. 2. GAFGLAS Mineral Surfaced Cap Sheet in an approved asphalt at an application rate of 25 lb./sq. ± 15%. 3. GAF Weathercote® MB+(Matrix 715 MB Caning), Applied at 1 to 13 J 4. Top Coat® Surface Seal SB(Matrix 602 SB Coating), Applied at 1 to 1.5 PUN Maxbmint Design Pressure: See Pastening above • • ••• • • • ... • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ..• NOA No: 030501.02 Expiration Date: 11/06/08 Approval Date:10/23/03 Page27of32 GENERAL LIMITATIONS: • • ••• • • • ••• •• •• • • • • •• •• • • • • • • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • ••• • • • • ••• WOOD DECK SYSTEM LIMITATIONS: . • • • • • 1 A slip sheet is required with Ply 4 and Flex Ply I ' 6 wee utal aA : • • caU1 *laid base or anchor sheet. • :•• • 2. Niininium 44" Dens Deck or V Type X gypsum board is acceptable to be installed directly over the wood deck. • • • • • • • ••• • • • • • • • • • • • • • • • • • •• • • • • • • ••• • 1. Fire classification is not part of this acceptance, refer tri a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EYT range and at a rate of 20-40 lbssq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down dm center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not fie. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Wfinimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for >n chanical enactment of anchorlbase sheet or membrane attachment is based on a minimums fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal ice value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing .Application Standard RAS 117. 7. Perimeter and corner areas shalt comply with the enhanced uplift pressure of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. (When this Ihrnitation is specifically referred within this NOA, General Limitation «9 will not be applicable.) 8. All attachment and sizing of perimeter Hailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wig load requirements. 9, The maximum designed piessure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation «7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No: 03.050L02 Expiration Date: 11/06/08 Approval Date:10123/03 Page 32of32 , ROOFING SYSTEMS (TG F11) Base Sheet (Optional): One or more layers Type GI, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (sntonth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (granule) or "Ruberoid Mop Plus" (granule). Coating: Karnak No. 97, 1 -1/2 - 3 gal /sq. 4. Deck: C -15/32 Incline: 1/2 Insulation: One or more layers perlite, glass fiber, isocyanurate, urethane, pertite /isucyanurate composite, perlite /urethane composite, phenolic. 1 -1/2 in. min thickness (offset from plywood joints 6 in.). Base Sheet: One or more layers of type G2 ur G3. Ply Sheet (Optional): One or mum layers of Type Gl. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Karnak No. 97, 1 -1/2 - 3 gal /sq. 5. Deck: NC Incline: 1/2 Base Sheet (Optional): One or more layers of Type 61, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), " Ruberoid Torch Plus" (granule). Surfacing Optional): Karnak "No. 97" or "169" at 1 -3 gal /sq or Grundy Ind. "20 F Eim lsiun" at 3 gal /sq. 6. Deck: C -15/32 Incline: I/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite /urethane composite, phenolic, 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One er more layers of "Ruberoid Torch" (smooth or granule), "Ruberoid Torch Plus" (granule), "Ruberoid Mop' (smooth or granule) or "Ruberoid Mop Plus" (granule). Surfacing: Gravel. 7. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, wood fiber, glass fiber, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite. wood fiber/isocyanurate composite, phenolic. Base Sheet: Two or more layers of Type G2 or G3. Ply Sheet (Optional): One or mute layers of Type G1. Membrane: One or more Layers of "Ruberoid Torch" (smooth or granule "Ruberoid Torch Plus" (granule). "Ruberoid Mop' (smooth or granule) o "Ruberoid Mop Plus" (granule). Surfadng: Karnak No. 97, 1 -1/2 - 3 gal /sq or gravel. 8. Deck: NC Incline: 1/2 Insulation: One or more layers perlite, glass fiber, 3/4 in. ntin, isocyanurate, urethane, perlite /isocyanurate composite, perlite/urethane composite, phenolic. 1 -1/2 in. min. Base Sheet (Optional): One or more layers of Type G1, G2 or G3. Membrane: One or more layers of "Ruberoid Torch" (smooth or granule), . "Ruberoid Torch Plus" (granule), "Ruberoid Mop" (smooth or granule) or "Ruberoid Mop Ptus" (granule). Surfacing: "AL MB Aluminum Roof Coating' at 1 -2 gal /sq. 9." Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in. min, isocyanurate, urethane, perlite / isacyanurate composite,, perlite/ urethane composite, phenolic, 1 -1/2 in. min. Base Sheet: One or inure layers of Type G2 "GAFGLAS #75 Base Sheet", hot mopped or mechanically fastened in place. Pty Sheet: One or more layers of Type G1 "GAFGLAS Ply 4 ", hot mopped in place. Membrane: "Ruberoid Mop FR" (granule). • Surfadng (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. '10. Deck: C -15/32 Incline: 1/2 Insulation (Optional): One or more layers perlite, glass tiber, 3/4 in. min, isocyanurate, urethane, perlite /isocyanurate composite, perlite/ urethane composite, phenolic, 1 -1/2 in. min. • Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet ", hot mopped or mechanically fastened in place. Ply Sheet: One or more layers of Type G1 "GAFGLAS Ply 4 ", or "GAFGLAS Ply 6" hot mopped in place. ;)•; Membrane: "Ruberoid Torch FR° (granule). e :' Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gat/sq or ea 't GAF Weather Coat Emulsion at 3 gat /sq. 3 1, Deck Isucyanurate. 2 in. min., wood fiber or glass fiber, .7 ; 7 "11 any thickness, Itot mopped or rnechanirally fastened in place. Joints Offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #75 Base Sheet", hot mopped or mechanically fastened in place. Ply Sheet (Optional): One or more layers of Type G1 "GAF61.AS Ply 4" or "Ply 6" hot mopped in place. Membrane: "Ruberoid Torch FR" (granule). -.. Surfacing (Optional): GAF Fibered Aluminum Coating at 1 -1/2 gat/sq or :GAF Weather Coat Emulsion at 3 gat/sq. fiftf ROOF COVERING MATERIALS (TEVT) ROOF COVERING MATERIALS (TEVT) 135 • * • OPKI • E FU). Continued • • ijO •• • • • •( . 12. Dec: l C- 14/32• • • • • • Incline: 1/2 Insutati sntePtisnd4):Ksocyainurrulet perlite or glass fiber, any thickness, hot mopped or mechanically fastened in place. Joints offset 6 in. Base Sheet: One or more layers of Type G2 "GAFGLAS #15 Base Sheet ", • 'het Awed urRnecharsically farstenee in place. F f SheeteOne qr nke lace: olTye%el "GAFGLAS Ply 4" or "I'ly 6 ", but •t elide Bwhereld 'torch t' • • • *Mernbraane ele . Surfacing (Optional): GAF Tittered Aluminum Coating at 1 -1/2 gat /sq or • GAF Weather Coat Emulsion at 3 gal /sq. 13. Deese N6 • • • • , • Incline: 1/2 • trbula l9 ( asocy.raur3le, wood fiber board, perlite, glass fiber, ens* ttarck� :eys, 4 leimpeit or mechanically fastened in place. AryAts offset• art. • • • • Base Sheet: ne qr n4nrltaeeet bf Type G2 "GAFGLAS #15 Base Sheet ", hot mopped in place. Ply Sheet (Optional): One or mare layers of Type 61 "GAFGI AS Ply 4' or "Ply 6" hot mopped in place. Membrane: "Ruberoid Turch FR" (granute). Surfacing (Optionat): "GAF Tibe;ed Aluminum Coating" at 1 -1/2 gal /sq or GAF Weather Coat Emulsion at 3 gal /sq. 14. Deck: NC Incline: 1/2 Insulation (Optional): Isocyanurate, wood tiber board, perlite, glass fiber, any thickness, hat mopped or mechanically fastened in place. Joints offset 6 in. Bas t: One or more layers of "GAFGLAS 1175 Base Sheet", hot pped in Ply Sheet:( Optional): One or more Layers of "GAF GUTS Ply 4" or "Ply 6" eid in place. 1es " Rubernid Torch FR" (granule). cOptional): GAF Weather Coat Emulsion applied at 3 gal /sq nr Aluminum Coating at 1 -1/2 gal /sq. /32 Incline: 1/2 (Optional): Pertite, fiber glass, isocyanurate, urethane, perlite/ u tate composite or phenolic. se eet: One or more Layers Type G2 or G3 base sheet, hot mopped or rnecttanicatly fastened. Ply Sheet (Optionat): One or mare layers Type 61, hot mopped in place. %• .Membrane: "Ruberoid Mop FR' or "Ruberoid Mop 170 FR" (granule). • Deck: C- 1"5/32 Incline: 1/2 • Inson (Optional): Partite, fiber glass, isocyanurate, urethane, perlite/ isocyanurate compostte or phenolic, offset 6 in. from joints. Base Sheet One ur more layers of Type G -2 or 6 -3 base sheet, hot mopped or mechanically fastened. Pty Sheet (Optional): One or more layers of Type 6 -1, hot mopped in peace. Membrane: One layer of "Ruberoid Torch" or "Ruberoid Mop" (smooth). Membrane: One layer of "Ruberoid Torch TR" or "Ruberoid Mop FR" • (granule) 17. Deck: NC Incline: i Insulation (Optional): Perlite, fiber glass, wood fiber, isocyanurate, urethane, pertite/isocyanurate composite or phenolic. Base Sheet: One or more layers Type G2 or G3 base sheet, hot mopped or easeharibostly fastened. • Pt et ( r+al): o or more layers Type Gl. hot mopped in place. Mete tayer of °Ruberoid Mop FR" or "Ruberoid Mop 170 FR" ranute 18. ck: tiC fiber, isocyanurate, ) ' , al): Perlite fiber gtass, wood Insuuret Incline: 1/2 lates rt . hane, f }enurate composite or phenolic. Base Sari �itiunal): Uue or mote layers of type 6-2 or G -3 base sheet, het owed or mechanically fastened. Pty Sheet (Optional): One or more layers of Type G -1, hot mopped in place. Membre: One layer of "Ruberoid Torch' (smooth), "Ruberoid Mup" (smooth). Membrane: One layer of "Ruberoid Torch FR", "Ruberoid Mop FR" or 'Ruberoid Mop 170 ER" (eremite). 19. Deck: NC Incline: 1/2 Insulation (Optional): One or more layers of perlite, glass fiber, isocyanurate, urethane, perlite /ism yenurate composite or phenolic, any thickness. Base Sheet: One or more pl :cs tit or 62, hot ;cropped or adhered with Karnak Che t:i4 at Co. "No. 81" or Gibson -Homan 'No. 6160" cold applied adhesive at 1 -1/2 gal /sq. Membrane: One layer of " Ruberoid Mop FR' or "Ruberoid Mop 170 FR' f granule), hot mopped ur adhered with Karnak Chemical Co. "No. 81" or Gibsun -Homan "No. 6160' cold applied adhesive at 1 -1/2 gal /sq. 20. Deck: C -15/32 Incline: 7/4 Insulation: Palyisocyanurate, any thickness. Base Sheet: "GAFGLAS 1175" (Type G2), mechanically attached. LOOK FOR MARK ON PRODUCT REPLACING FLAT TOP ON CAR GARAGE ROOF Passed 4F Inspector Comments Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 09/25/2008 Inspector: Rodriguez, Jorge Owner: TRACY, HELEN Job Address: 1099 97 Street NE Project: <NONE> Miami Shores Village, FL Contractor: KAWALEK ROOFING & PAINTING, INC Building Department Comments Wednesday, September 24, 2008 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Block: Permit Type: Roof Inspection Type: Final Roof Work Classification: Roof - New Phone Number Parcel Number 1132050170070 Lot: Phone: 786- 277 -9540 Page 2 of 2 REPLACING FLAT TOP ON CAR GARAGE ROOF Infraction Passed Comments TIN CAP SPACEING True Passed tit4S- Inspector Comments 0 L y V" o UK - gyp CACSS F u5°' To dal■CC 6 k ) 11AQ IlltUCTIoAk ctS Sanal■M . HottCC o Failed Correction Needed Re- Inspection Fee ($75) No Additional Inspections can be scheduled re- inspection fee is paid. until Inspection Date: 09/23/2008 Inspector: Rodriguez, Jorge Owner: TRACY, HELEN Job Address: 1099 97 Street NE Miami Shores Village, FL Project: <NONE> Contractor: KAWALEK ROOFING & PAINTING, INC Building Department Comments Monday, September 22, 2008 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795 -2204 Fax: (305)756 -8972 Inspection Number: INSP -93486 Permit Number: RF -8 -08 -1586 Block: Permit Type: Roof Inspection Type: Tin Cap Work Classification: Roof - New Phone Number Parcel Number 1132050170070 Lot: Phone: 786- 277 -9540 Page 1 of 2