BPP-08-1420_Plans •
NoTEI C4� T DRAWN BY:
N{
OP ❑F POOL j ELEVATION IS MIN, ALL CONDUCTOR CLEARANCES SHALL
❑P
"
I _ 6 LOWER THAN F.F.E. OF HOUSE COMPLY WITH N,E,C, 680,8 FOR SPECIFICATIONS CODE NOTES co Des�
OVERyEAO *9E �� ���� NtAY W AVHALT' 00 ; u OVERHEAD, AND N . E . C , 680,10 FOR C ❑DE REQUIREMENTS - Private swimming p ool and s pas must comply with ch 424 & R4101. �� L7
$ >r'�. POOL SIZE: a x a -�° POOL DEPTH: a' To a- 9 P P P Y P
. ,E,C 2005 . POOL PERIMETER: �2- o" F POOL AREA S4. FT.: 25e s= Florida Building Code, 2006,
UNDERGROUND REFERENCE N S
_ ..
mod",
D
x VOLUME: (GALLONS) 7,G3a TURNOVER RATE 2.12 r;F , COG- Mechanical Requirements= All piping, equipment and materials used in the plumbing system of
o "c+) ro P. � y jo c � FNR` � /� swimming pools (Spas) that are built in place shall conform to the Florida Building Code,
A u }p POOL EQUIPMENT AUXILLIARY POOL EQUIPMENT
v
,
.. s9.oSY 5 � 'd, o, Plumbing. (424.2.3 & R4101.3). All piping materials shall be installed in strict accordance with `
k. POOL PUMP: HF AUX. POOL PERIMETER: wA the manufacturer's Installation standards. Compliance - All materials, p iping, values,
.. ASPHALT - � ,",- r.. P
,r c -aoo AUXILLIARY PUMP• NA a ui ment or a liances enterin Into the construction of swimmin ools (S as) or \
POOL FILTER: q P PP � 9 9 P P p
3o'- portions thereof shall be of a type complying with the code or of a type recommended e j
wipe PLUG OR ANTI VORTEX GRATE POOL INLETS: s AUX. POOL JETS:
N P YP YP
and approved by a nationally recognized testing agency or conforming to other
C\2 CO
N/A REMOTE PLACES) �? 2E' HYDROSTATIC F SKIMMER: i 0 COLOR WHEEL: AUX. POOL LIGHT: NA ❑ P Y
p
reco gn i zed standards acceptable to the administrative authority
o ,
MAINTAIN MIN. TO BE A5TENED
9
G
5E KS ?. ; iu 1 - I /2 WITH SC FINS POOL LIGHT: a AUX. HEATER TYPE N/A c E n
O - e REQU R
VALVE n 'Weer' De i
,
E i m s n Construction and workmanshi shall be in conformit with ANSI /
r
E
PER CODE R M ��c� O POOL HEATER TYPE: AUX. HEATER SIZE: N A NSPI 3,4,5 Design 2003, published by the National Spa and Pool Institute, or other accepted
F SELF- CLOSING/ SELF - LOCKING
boo E� Q ����� REQUIRE® POOL HEATER SIZE: N/A RAISED: NA engineering practices.
FAVER DECK
ELEV. i�.li MAINTAIN MIN r` z FENCE: 4' H HIGH MIN. CLEANING LINE: Yes STEP(S): N/A
�� t R' >> lu j ENTRAPMENT Testing and Certification= ALL pool and spa suction inlets shall be provided with
..
5E7BACK5 fl. AND NON-CLIMBABLE , ,.: ; CLEANING SYSTEM: wA BLOWER: N/A n cover that has been tested and accepted by a recognized testing facility and comply
PER CODE w IF IGH HORS REMOVE FENCE/ CHLORINATOR: SALT- c/�GeN. TURNOVER RATE: N/A
with ANS /ASME A112,19,8M, 'Suction Fittings for Use in Swimming Pools, Spas, Hot Tubs, and JOHN M. CARROLL
" " .. .. _' O WALL, OWNER MUST REPLACE POOL fIN15H ITEMS Whirlpool Bathtub Appliances. Exception= Surface Skimmers,
OOR WINDOW ALARMS uU WITH A 4' FENCE ON COPING: HANDHOLDS: Yes
PER N � OWMIER'S PROPERTY Safety Note= Do not use or operate pool or spa if the suction inlet fitting is missing,
z ° ,N \
ac SECTIO u, O ° TILE: 6° INTERIOR FINISH: c/e
. a/ .0 w u, EE POINT . ROCr, BED broken, or loose,
+ 0
424.2.17.1.9
U w d �
—
o T' i1` - " z SWIMOUT: Yes DECK S.F.: 357 sF
� WALL POINT DETAIL =
cn 0 O
Entrapme Avoldance If the suction Inlets stem such automatic cleanin system is
o: x z P Y as an au oma c c 9 Y
,
- . _ Q
LADDER N!A CAPPING S.F.: N/A a vacuum cleaner system which has a single suction inlet, or multiple suction inlets which
1,{15 Q Q u� o� N.T.S. can be isolated b l then ti inlet shall protect a entrapment
U w a- NA DECK TYPE: FAVeR
f#t # cn Y valves, en each suction P against user P
b either an a roved
� - z Y roved x cover, e 12 X 12 rate or larger, or other approved
l PP antivorte 9 9
(°` " WATER FEATU KE5
g.�3' � 1�,1i ° u � u means per FBC 424.2.6.6.4 & R4101,6.6.4,, a,
z AUX. P SIZE: wA FOUNTAIN FEATURE N!A N /,q In odo�tion, all pools and spas shall be required. to have a backup system which shall
v vers be Missing. Alternate vacuum relief devices
s
Q z
1- 1 /2 11 PVC TEE TO LIONS HEAD: wA SHEER DESCENT: ; s�.^ shall Include e6ther=
MATCH V ENT LINE 517E SPRITZER /SPRAY HEAD: wA FEATURE PUMP N!A Z A roved Vent Pi Release System
` ¢ THERAPY JETS: NIA OTHER N!A 3, Other Approved Devices or Means
LIGHT PEATURES
WINDOW SCREEN
P. E. No. 41610
Suction Inlet Per Pump A minimum of two suction inlets shall be provided for each pump in
1 .111 !c Gat' T7.5J' TYP. 2 FIBER OPTIC SPOT (S): N/A No
° ��, °. the suction Inlet system, separated by a minimum of 3 feet or located on two different
9p° PERIMETER LIGHTS: N/A LIGHT SWITCH: Yes # OF CO N/A planes] i.e., on the bottom and one on the vertical wall, or one each on two separate
6.14`
ti
vertical walls. These suction inlets shall be plumbed such that water is drawn throw h
ADDITIONAL FEATUKE5 P g
I° x.35" them simultane=ously through a common line to the pump, per FBC 424,2.6.6.4 & R410L.6,6,4.
3 1,- PVC SLEEVE POOL ENCLOSURE: A PRM/ New FeNCe ;BY oYr;2�sJ GLASS BLOCK TYPE: wA
r I whit PRLSSED IN PLACE N A N A Cleaner Fittings= Where provided, the vacuum or pressure cleaner fitting(s) shall be
GLASS ROW
,c� FOOTE S L.F.• / S HT: / co LO
•_ _ ,. °¢ R located in an accessible position at least 6 inches and not greater than 12 inches below �+ i{�
bisc r >) , /Z DECO - O - DRAIN: ti!a GLASS ROWS WDTH N/A
9Q 40 l z the minimum operating water level or as an attachment to the skimmer(s). All clearner d' ►FJ
Qrt01 I g e pro Y PP roved permanent) PILING POOL: N/A # OF GLASS BLOCKS. wa suction Inlets shall btected b an a , installed, O O
GROUND LEVEL, POOL DECK OR
ft PP
Y self- closin 9
a er, per FBC 424.2.6.6.5 & R4101,6,6.5,
to ASF?tIAL ;'.�1 MAX. POOL WATER LEVL, c0
r� spa" �A I WHICHEVER 15 GREATER Valve= Valves shall be made of materials that are approved in the Florida Building
ad s a (w) I code, Plumbing, Valves located under concrete stabs shall be set In a pit having a 10 LO
least dimension of five pipe diameters, minimum 10 inches, fitted with a suitable cover,
THE AT{V105PHERIC VENT TEE SHALL BE LOCATED NOT per FBC 424.2.8,1 & R4101.8,1.
I LE55 THAN 8 °, MEASURED FROM THE BOTTOM OE THE Waste Water Disposal= Direct or indirect connections cannot be made to existing facilities ILD LO
I_ I STRAIGHT LEG Of THE TEE. ABOVE THE GROUND LEVEL, without the prior approval of the administrative authority, per FBC 424,2,10 & R4101,10,
POOL DECK, OR MAXIMUM POOL WATER LEVEL,
_
.� .. Tests All col p iping shall be in and ap before cover or concealment. It z
WHICHEVER PROVIDES THE GREATEST ELEVATION. P
shall be tested P 9 P PP _
P and proved tight under a static water or air pressure test of not
a
less than 35 psi for 15 minutes. Per manufacture recommendations, no air test shall be ed
R1L, �°ir approved for 'PVC pipe and fittings, per FBC 424.2.121 & R4101,12.1, LLB f�
#
-� - - -- ATMOSPHERIC /ENT DETAIL Water Heating Equipment= Swimming pool water heating equipment shall conform to the design, � W Q'
(75': RA construction and installation requirements In accordance with accepted engineering '_ — z
N.T.Q. practices and shall bear the label of a recognized testing agency, and shall include a Ur Q
22 A�F'f4Ai.7
consideration of combustion air, venting nd as supply requirements for water heaters
Sec. 424.2.14.1 & R4101,14,1. It must contain a thermostatic or high- pressure control switch so z
the pool water does not exceed 104 degrees F. Sec, 424.2.14,4 & R4101.14.4. Water heating L1J +� b O
' equipment shall be installed with flanges or union connections adjacent to the heater, O Q) co
S I TE PLAN swimming pool water heating equipment shall have an Internal check valve, per FBC 412
N .E b
CO
SCALE 1 " =20' [� 2 WAY JANDY W/ ACTUAT ❑R (�] BALL VALVE Pool & spa covers= Pools and spas with heaters shall be provided a cover or other
means to reduce heat loss, per FBC 13- 6121.ABC.2,3.2. Z b
3 WAY JANDY W/ ACTUATOR 3 WAY JANDY VALVE 3: 4-)
Pool Enclosur Residential Pools shall comply with FBC section 424.2.17.1 - 424.2,17,15 & R4101. - R4101.17,15 CC.0 O O
N A RROW I Ladders and Steps= All pools shall be provided with a ladder or steps in the shallow end CO w w
LE where the water exceeds 24 inches, Where water depth exceeds 5 feet, there shall be
FOR P � 0 � LOCATION � I V � �/ � ladders, stairs or underwater benches /swim outs in the deep end, per FBC 42412,18 &
R4101.18,
Fitters= The entire design of matched coi- 4 )orents'shatl- have` "sufficient 'capacity to
provide a complete turnover of pool eater n 12 hours or less per FBC 424.2.20 &
, LEGAL DESCRIPTI ❑N 8olFl °.
. .
. Pool Fittings= Pool fittings shall be of an approved type and design as to be
INLINE appropriate for the specific application, per FBC 424,2,2.1 & R4101,21 Per FBC 424,2,13.2
LOT, 12 BLK. 180 SALT - C/L joints and connections and FBC plumbing Sec, 605,21, purple primer required on PVC ' ^
SUBDIVISI ❑N= MIAMI SHORES VILLAGE GENERATOR 90 SF CARTRIDGE piping rr �/1
PLAT BOOK 43 PG= 51 MANUF HAYWARD w
g Skimmers= Skimmers shall be installed on the basis of one per $00 SF of surface area or
PUBLIC RECORD ❑F: MIAMI - DADE COUNTY FL, MODEL; 900 �f'1E fraction thereof, per FBC 424 12,21 ,2 & R4101,21.4. P
O pPf tj Hydrostatic Relief Device= In areas of anticipated water table an approved r T l
PC ofa hydrostatic relief device shall be Installed, per FBC 424,2.21.4 & R4101,21.4. Exception
1 W
jP� is plastic liner pools. O
Concrete / Siteeli All floors & walls of pool to be pneumatically applied concrete with a
1 1/2" TYP
PUMP ER HAIR LINT RECIRCULATION min 28 day compressive strength of 2500 psi, All reinforcing steel to conform to A615
BAILEY RESIDENCE STRAINER - 80 GPM grade 60.
1 1/2" TYP ®60' T.D.H. Soil Statement= Based upon rational analysis, the soil In this area has a 2000 psf bearing
101 N . E . 9 7 STREET capacity after excavation and compaction. Should any muck, marl, or other organic soils O
be discovered on excavation, they should be removed in their entir This pool requires A
2000 psf bearing capacity. I ( ® l
MIAMI SHORES FLORIDA Pool Stakingi This design engineer assumes no responsibility for pool construction In
?� easements or required setback areas. Plot plans not prepared from legal surveys of
the existing lot and residence are so Indicated. The pool contractor shalt verify all
dimensions In the field and establish tot tines. The pool contractor shalt establish locations
A IR E I.E of all utilities at the site. Min, clearance dimensions shall be held as required by the local
BARRIER NOTE- �r�J' O PAD regulatory agency. In general, hold a distance of 10 feet from overhead electric lines to
OUTDOOR SWIMMING POOLS AND SPAS SHALL BE PROVIDED ��� i o , open pool water.
WITH A PERMANENT BARRIER THAT SHALL BE INSTALLED, • ' W Exist{n Structures= The p ool contractor shall alwa s take all recautions to rotect
INSPECTED & APPROVED PRI ❑R TO PLASTERING OR FILLING 12 CI,0
WITH WATER. SUCH PERMANENT BARRIER SHALL BE IN , o) g P y P P
B AQ existing structures from failure by sheeting and /or shoring or other methods. the
OP 3� r
ACCORDANCE WITH SECTI ❑N F.B.C. LATEST EDITI ❑N. � �Nr; � design engineer accepts no responsibility for the safety of existing structures. The contractor shall backfill the ool shell wit P 9
�
P ac fill=
� � h caution. The tumble shall not
( rJC
P
6 be disturbed. Backfill shall be accomplished with clean construction fill, W
C
n rode fil free of
rJ
tJ
9
, ►t� 0RA organic material and shall be placed in 12' lifts, each lift shall be compacted to 95% per
fw A
W
2 I N ASTM D -1557, 00
SPECIAL PR ❑NISI ❑NS t
I t/
t Warning =
t the
V OL - 0 O� 2
o To empty P Y P ool after construction for r or any other reason ,
1
1, ALL SWIMMING POOLS, SPAS AND HOT TUB AREAS SHALL BE �Ay 2� F I,INE5 1 hydrostatic uplift pressures beneath the pool must be eliminated to prevent the pool from
VI
� B L L CA ION PERM WITH A
THE POOL AREAARNING SIGN IN READILY P �IrJC �CAtA1CUPE exper enced an d eliminating n upllf t pressurest a pool contractor or pool repair contractor
(APPENDIX F ANSI - NSPI -5 -95) S�I��C P 00 1, 0 0 Diving = No diving board and no diving is allowed on any pool less than 8'0' deep and co
e0 O
2. EACH SAFETY WARNING SIGN SHALL WARN AGAINST SHALLOW �a 0� G 0 s pecifically des for d1vin This p ool Is not designed for dlvin unless s pecificall y
.� Y F g P Y 9 9 P 9 9 P Y
WATER DIVING, PREVENTION OF DROWNING & INCLUDE THE y' FIrn stated on the site plan. 4__' T
F ❑LL ❑WING STATEMENT= 'THERE IS NO SUBSTITUTION FOR ADULT POOL M/D �
Gas Piping Gas piping shall comply with the Florida Building Code, Fuel Gas Sec. 424.2.15 &
SUPERVISI ❑N OF SMALL CHILDREN. IT IS STRONGLY C2) 8' MAIN DRAINS W/ 84101,15 �
RECOMMENDED THAT AT LEAST ONE ADULT RENDERING CHILD
SUPERVISION BE TRAINED IN ARTIFICIAL RESPIRATION AND /OR ANTI VORTEX COVERS Electrical= Electrical wiring and equipment shall comply with the 2005 National Electrical
CARDIOPULMONARY RESUSCITATION (CPR)' MINIMUM 3' APART. Code SEC 680. IF REQUIRED BY THE LOCAL MUNICIPALITY THE POOL/ SPA DECK SHALL BE BONDED W
PER 2005 NATIONAL ELECTRIC CODE SECTION 680
EQUIPMENT ISOMETRIC ►—+
ALARM NOTE=
N. T. S.
l i Lo
ALL WALLS THROUGH WHICH A DOOR PROVIDES ACCESS 6' X 6' X 1.4' W.W.F. ALL IDEAS, DESIGNS ARRANGEMENTS AND PLANS INDICATED
TO THE POOL SHALL BE EQUIPPED WITH AN ALARM
EQUIPOTENTIAL BONDING GRID` SINGLE WIRE:
AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN IS BEING OR REPRESENTED BY THIS DRAWING, ARE OWNED BY AND THE
PROPERTY OF THIS OFFICE AND WERE CREATED, EVOLVED AND O
OPENED, THE ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. z PER THE BOARD OF RULES AND APPEALS MEETING ON MAY 10, 2007 AN DEVELOPED FOR USE ON AND IN CONNECTION WITH THE SPECIFIED
30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE ALTERNATIVE METHOD FOR SWIMMING POOLS AND SPA EQUIPOTENTIAL BONDING PROJECT. NONE OF SUCH IDEAS, DESIGNS, ARRANGEMENTS OR
OF EMITTING A SOUND OF SUFFICIENT VOLUME TO BE HEARD WITHIN GRID OF POOLS AND SPAS WITH LIGHTS OF 15 VOLTS OR LESS OR NO LIGHTS MAY PLANS, SHALL BE USED BY OR DISCLOSED TO ANY PERSON,
THE DWELLING. THE ALARM SHALL BE EQUIPPED WITH A MANUAL USE A SINGLE WIRE GRID ( #8 AWG) WHEN INSTALLED AS FOLLOWS: FIRM OR CORPORATION FOR ANY PURPOSE WHATSOEVER WITHOUT
MEANS TO TEMPORARLY DEACTIVATE THE ALARM FOR A SINGLE EQUIPMENT PAD SIZE TO THE WRITTEN PERMISSION OF TWENTY FIRST CENTURY ENGINEERING.
OPENING, THE DEACTIVATION SWITCH SHALL BE LOCATED AT BE DETERMINED IN FIELD THIS INCLUDES UNPAVED SURFACE AS WELL AS POURED SURFACES AND WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECED-
LEAST 54' ABOVE THE THRESHOLD OF THE THE DOOR. EQUIPMENT PAD DETAIL ) OTHER TYPES ATTACHED TO F THE PAV
POOL REINFORCING STEEL OR COPPER CONDUCTOR AND E BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS
NITS, GRiD (SINGLE #8 AWG WIRE) AND ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY
2) BURIED TO A MIN. DEPTH OF 4" NOT TO EXCEED 6" (BELOW GRADE VARIATION FROM THE DIMENSIONS AND CONDITIONS SHOWN DATE
3 CONNECTED BY A MIN. OF FOUR POINTS UNIFORMLY SPACED AROUND THE BY THESE DRAWINGS.
ALARM NOTES 06/30/08
ALL WALLS THROUGH WHICH A DOOR PROVIDES ACCESS TO THE POOL SHALL BE EQUIPPED WITH AN PERIMETER OF THE SWIMMING POOL AND OR SPA AND
ALARM AUDIBLE WARNING WHEN THE DOOR OR ITS SCREEN IS BEING OPENED, THE ALARM SHALL SOUND SPECIAL PR❑VISI ❑NS, 4) CONNECTED TO AN EQUIPOTENTIAL GRID (SINGLE #8 AWG WIRE) WITH A PROJECT N0.
CONTINUOUSLY FOR A MIN, 30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE OF EMITTING A 1. ALL SWIMMING POOLS, SPAS AND HOT TUB AREA; SHALL BE SOLID COPPER BARE CONDUCTOR NOT SMALLER THAN #8 AWG AND REVISIONS
SOUND OF SUFFICIENT VOLUME TO BE HEARD WITHIN THE DWELLING, THE ALARM SHALL BE EQUIPPED WITH PROVIDED WITH A PERMANENT SAFETY WARNING SI(N IN READILY 5) CONNECTION SHALL BE MADE EXOTHERMIC WELDING OR BY LISTED
T I I C
A MANUAL MEANS TO TEMP❑RARLY REACTIVATE THE ALARM FOR A SINGLE OPENING. THE DEACTIVATION VISIBLE LOCATION FROM THE POOL AREA PRESSURE CONNECTORS OR CLAMPS THAT ARE LABELED AS BEING SUIT # DATE DES CRIPTION BY
SWITCH SHALL BE LOCATED AT LEAST 54' ABOVE THE THRESHOLD OF THE THE DOOR. (APPENDIX F ANSI - NSPI -5 -95) FOR THE PURPOSE AND ARE OF STAINLESS STEEL, BRASS, COPPER, OR DRAWN BY
2, EACH SAFETY WARNING SIGN SHALL WARN AGAINST SHALLOW COPPER ALLOY AND jP
WATER DIVING, PREVENTI ❑N OF DROWNING & INCLWE THE 6) THE EQUIPOTENTiAL BONDING GRID (SINGLE #8 AWG WIRE)
N OTE: LAYOUT OF POOL AND HOUSE CONSTRUCTION NOTES NOTE= ALL CONDUCTOR FOLL ❑WING STATEMENT= 'THERE IS NO SUBSTITUTIltI FOR ADULT SHALL EXTEND UNDER PAVED AND UNPAVED WALKING SURFACERS FOR ONE SHEET NO. OF
DRAWN BY SUBMITTAL Of 5UKVEY FROM (1) POOL LOCATION MUST COMPLY WITH N.E,C. (ARTICLE 680.8) CLEARANCES SHALL COMPLY SUPERVISION OF SMALL CHILDREN. IT IS STRONGLY: METER (THREE FEET) HORIZONTALLY BEYOND THE INSIDE WALL OF THE
THE POOL CONTRACTOR. TWENTY FIK5T WITH, N.E.C. 680.8 FOR RECOMMENDED THAT ~AT LEAST ONE ADULT RENDERING CHILD POOL.UNDER EXISTING CONDITIONS THIS REQUIREMENT MAY BE LESS THAN
CEt,ITURY ENGINEERING 15 NOT RESPONSIBLE (2) POOL BARRIER - DOOP ALARMS � PJEW f=ENCE (13/0) OVERHEAD. AND N,E.C. 680.10 SUPERVISION, BE TRAINED IN ARTIFICIAL RESPIRATION AND/OR AS STATED ABOVE.
FOR ANY DISCREPANCIES DUE TO ANY FOR UNDERGROUND. CARDI❑PULM ❑NARY RESUSCITATION (CPR)'
ILLEGIBLE DIMDd5ION5 OK UTILITIES NOT REFERENCE N.E.C, 2005
SHOWN ON 5URVEY.
ll
DRAWN BY:
®a� R IREME ECU
N❑TEJ NG/ SELF LC.?CKING Co De /
,ELF -CLO
NOTE, ALL CONDUCTOR CLEARANCES SHALL GATES REC�UIRE®
. FENCE: 4' HIGH (MIN.) ! ;
` s
COMPLY WITH N, .C. 680,8 FOR BASLE
TOP OF POOL ELEVATI ❑N IS MIN. F A ND NO
N CLIM 2 #3 c
6' LOWER THAN F,F,E. OF HOUSE OVERHEAD, AN RE „C, 680,10 FOR % - IF NEIGHBORS REMOVE FEN E,W, CENTERED 8'
UNDERGROUND, REFERENCE N,E,C, 2005 �° L OWNER MUST REpLAC'E
• 6' 12' TYP.
WITH
/
WAL , A 4' FENCE ON
”
G
PRO'P'ERTY 36' SHEER DESCENT
12
—1
OWN ER'S
45' - ° OW SEE DETAIL PAGE 2 a Q �e > \-<\
r 2) 8 N/D SEE
RA MAINTAIN MIN. DECK ED REAM $' LONG X / I J- �t C
I c
07
DETAIL' PAGE - 1 18 SETBACK E HIGH W/ 1) 3 SHEER / COPING TILE FACE '" n
EXISITNG r DESCENT
DRIVEWAY TYP. �E DETAIL PAGE 2 / CODE —
- -- —
i IIlEA `
_ OVERLAP va � , C,9. °
#3 ®Qt
• 's CONT.
r I MIN, OF
°
I 1 II 24 TYP. - �
WATER LINE _
C I I III �. WATER LINE T T
o JO HN M. C ARRO
18' X 4' SWIMOUT HAND , I DRASJFIEGD I W (TTYP.) " OCEW #3 @ 5' O,C,E,WI I'
W/ TILE EDGE H ❑LDS I / f� # 3 ®10 CENTERED
SEE DETAIL PAGE 2
N I
CLEANING LINE � � I I_ I •
I W/ VAC LOCK I' I % / OVERLAP
= I LED LIGHT I II a� I / MIN. OF 24
r I I _ 4 o t �
III sr 0
n J
18"
_
•
. , SEE WALL
I
�i V I l .�
� D SWIMOUT DETAIL
TO
REC � SECTION DETAIL @ 5
0
10 MIN. ,. O.C.E.W
I _
#3
Pik I 1!2' vENT LINE 10'
3 STEPS -SEE I I I' I RiFY�N F� X NOT TO EXCEED 32' N.T.S.
DETAIL PAGE 2
VERIFY IN FIELD
91 4'
2 POOL AA /D LINE ` y RAISED BEAM REBAR DETAIL ' P. E.' No. 41610
r - -- 1 1/2 FEATURE LINE �,-..
F.F.E. 11.61 0 -------- - - - - -- r -- - - - --� Apt _u,l
N.T.S.
I ! /2
' �it. tr .�s 4_ ;, k G Q iJ 9Y . &( . ..� i �
s 1..- �'�f'a Fii�'11zI4T
PAVER DECK I I " POOL RETURN LINE ; D,. t- , GJ 2
III 2" VAC LIME
ELEV. 11.11
POOL TYPE "0 " I 2" SKIMMER LIME � /
p Zy /o�� CO LO
' 4
BAILEY RESIDENCE NON ' !DIVING ` " GATE: � 0
1015 N.E. 97 S TREET z t 2 #3'S CON a'
MIAMI SHORES, FLORIDA v WINDOW R
n1s L w G TYP
12
R * l I JDOW c � o
DOO I (�
POOL BEAM
PER SECTION 424.2.1 4. 1.9 1 0 A w z Y o , , C\2 C\2
LO
EXISTING 1 -STORY w o a C) ►t0
CBS RESIDENCE u w a w t! <••r'`'t' N "^
0
Z � 1i! VJ Vr
Wa
CONC. PAD FOR EQUIPMENT - SIZE TO BE •4,•
DETERMINED IN FIELD - SEE PAD DETAIL FORT ' : 1 36 SHEER DESCENTS i4
THICKPJE55 AND REINFORCEMENT PAGE I O SEE DETAIL PAGE 2 W w
rb(7 REFER T❑ WALL 0
W
SECTI STEEL
SCHEDULE FEATURE DETAIL _
I .� � z (D
STAIR DETAIL (SOUTH) N,T,S,
(� N
4.T,S. z +� O
LLJ O
Co
C�2 CO
POOL PLAN N w CO
SCALE 1/8" 1' -0" Z '� 'b
CD $-4
'
02 0
co �%., w
RADIUS EDGE
PROVIDE A HAND HOLD NO
6 MORE THAN 9 ABOVE THE
NORMAL WATER LEVEL. C AP TO MATCH COP ING
PLASTIC WATER STOP
6 NOTE! CERAMIC TILE
HAND HOLD TILE
'Ir MAX. SPACING
HA NDHOLD DETA SHALL NOT
243 CONT, N.T,S, EXCEED 48' Q a 1
PRECAST INTERLOCKING BRICK LOCATE @ WATERLINE
COPING PATIO SET IN SAND D
24' SHEER DESCENT UNIT W
ALL ORGANIC MATERIALS — e
TILE � 1. THIS SAFETY VACUUM RELIEF SYSTEM IS A P
REMOVED N ❑N- MECHANICAL VENT SYSTEM THAT WILL LIMIT THE I Q
SLOPE TRANSMISSION OF SUCTION AT THE OUTLET TO A PO ❑L SHELL p n
WATER LINE ►�--I n
— — — — — — — MAXIMUM OF 4.5 INCHES OF MERCURY.
2. THIS SYSTEM IS A BACKUP TO PROVIDE SUCTION 1' LINE
IMPORTANT NOTE RELIEF SHOULD ENTRAPMENT OCCUR.
MIN VERTICAL 2'-S" G" WALL TO 5' RJ WATER DEPTH
SHALLOW END 3' - .I NO DIVING BOARD AND NO DIVING IS ALLOWED ON ANY POOL 3. POOL AND SPA SUCTION INLETS SHALL BE
DEEP END 2" COVER CENTER LESS THAN 8'-0' DEEP AND SPECIFICALLY DESIGNED FOR
PROVIDED WITH A COVER THAT COMPLIES WITH
DIVING, THIS POOL IS NOT DESIGNED FOR DIVING.
ANSI /ASME A112.19.8M
G" WALL UP TO 5' SHEER DESCENT WATERFALL
WATER DEPTH * 8 WALL 4. THE VEL ❑CITY ON THE SUCTION SIDE OF THE
APPROVED + * FLOOR IN MORE THAN CIRCULATION SYSTEM SHALL NOT EXCEED SIX (6) FPS, N.T.S.
FINISH l 5' SEE NOTE BELOW i
/ WATER LINE 5. CHECK VALVES CANNOT BE INSTALLED ON THE
STEELTEX FORM. M jN � ' SUCTION SYSTEM.
�KRAFTBOARD OR EQUIV. D RAIN
r - j 6. THIS SYSTEM SHALL BE INSTALLED AND TESTED BY r
UP TO 5 DP. USE #3 @ I O" O.0 E.W
17 MAXIMUM SLOPE 11° SLOPE A QUALIFIED, LICENSED SWIMMING POOL PROFESSIONAL.. r
OVER 5' DP USE #3 @ 5 " O.0 E.W DESIGN SLOPE (TYP,) MAX, 7, THE VENT LINE LENGTH MUST NOT EXCEED THE
CENTERED IN WALLS AND FLOORS
7 ' TOTAL LENGTH OF THE MAIN DRAIN LINE. W
10" THICK FLOOR 19' cc
8. VENT OPENING MUST BE COVERED WITH WIRE MESH
TYPICAL WALL 5ECTION P ❑DL SECTI ❑N SCREEN TO PREVENT INSECTS, DEBRIS C❑LLECTI ❑N AND r
N .T.s. BACTERIA.
I
N.T.S. 9, LABEL VENT= POOL SAFETY DEVICE- D❑ NOT
HANDLE
VENT PIPE MAXIMUM LENGTH �)
I
/ .(21 90 BENDS PUMP AVG. VENT MAX. �4
/\ 00 SIZES FLOW SIZES LENGTH
J1/2 " LIQUID TIGHT PVC CONDUIT �{
�/ I Q 1 HP 60 GPM 1 -1/2' 41 FT r T
N 1.5 HP 75 GPM 1 -1/2' 41 FT °
DESCRIPTION BREAKER SIZE N 2 .5 HP 135 GPM 1 -1/2' 73 FT
8 . '-' 2 HP 100 GPM 1 -1 /Z ' 54 FT
SPST LED LIGHT
9 WP GFCI, 1 POLE, 1 PHASE, 115 V, 16A MAX 20A r T
>
WP
WATERPROOF GFCI, MIN. 10 AND MAX. 20 TO WATER 10 A MAX 20A 1) 90 BEND 1 1/2' VENT LINE
BASED ON FOLLOWING EQUATION
POOL RECIRC PUMP, 2 POLE, 1 PHASE, 230 V, 8.3 FLA, z:
PANEL 12 12 - 12, THHN ONE HP PUMP FLOW RATE 60GPMf?60'TDH
SALT CHLORINE GENERATOR 2 POLE 1 PHASE 15A MAX 20A A 60GPM / (60X7.48) = 0.13369 CUBIC FEET Q
PER SECOND.
SALT CHLORINE GENERATOR 12 -12 -12 THHN
I
FLOW X 3 SECONDS (CODE REQUIRED) _
I
MAIN DRAIN MAXIMUM SIZE OF OPENING,
9 POOL RECIRC PUMP, 12- 12 -12, THHN
TC 12' 0 .13369 X 3 = 0.4011 CUBIC FEET
MAX, AREA OF 1 -1/2' VENT PIPE = .01227 SID FEET
THE ALLOWABLE LENGTH = 0.4011 / .01227
LED POOL LIGHT, 1 POLE, 1 PHASE, 115 V, 10A MAX 15A Z I = 32 FEET
P❑ ❑L THEREFORE, FOR A 1HP PUMP AND 1 -1/2' VENT
T_ LINE, THE MAXIMUM LENGTH OF PIPE IS
NOTE ! P PROJEC T N N WATERPROOF, SINGLE 1 1/2' VENT LIN T MAIN DRAIN 32 FEET
E DATE
1. BOND ALL BOXES, RAILS TC TIME CLOCK POLE SINGLE THROW
LIGHTS, STEEL & DECK, ECT. W/ TOGGLE SWITCH 06 .
#8 THHN WIRE IN POOL AREA PER wP WATERPROOF DISCONNECT
NATIONAL ELECTRIC CODE 680 MANUAL STARTER DISC. MANUAL DISCONN REVISIONS
® WITHIN SIGHT OF POOL # DATE DESCRIPTION BY
2. POOL LOCATION MUST COMPLY M SWITCH HEATER
DRAWN BY
WITH NATIONAL ELECTRIC CODE.
JP
SAFETY VACUUM RELEASE SYSTEM (S VR S ) SHEET N0. OF
NJ.R
I •
P 2
rkRMMT 4
MIAMI SHORES ViLLAGE
CITY APPROVED -J1 C
`
Y00000
o v 21c(J
••
coo
MECHANICAL
STA3E AM COUNTY RULES AND REGULAPONS
7
�t ',e +Fn ��� � yf L�� ✓ •
tl •
A V
L
3 j
i
i
A
I
II I
}
i
L
i
3
3
r
i
III