Loading...
746 NE 95 St (8)A higher degree of comfort and control. Hayward H- Series Pool & Spa Heaters Patented non- corrosive polymer headers and stainless steel tube sheets provide durability that lasts. CPVC capability reduces installation time and cost. The benchmark for an advanced heater system is the precision it brings to the water temperature— and ultimately the comfort it provides. The induced draft and electronic models both incorporate digital temperature read -outs, with the ability to easily set the correct temperature and monitor system diagnostics, to create the most enjoyable pool environment possible. as it is to your pool or spa. Built to withstand even the harshest of conditions, the H- Series is the only line of heaters that employ a rust resistant water path. Unlike other models that use heavier cast iron or costly bronze assemblies, Hayward's patented non- corrosive headers are manufactured from a modern injection - molded polymer process. The benefits are lighter weight for easier installation, along with rust free performance. With energy - efficiency top of mind, it is crucial for heating systems to operate as efficiently as possible. Insulated combustion chambers, including one inch thick FireTile,° are featured in every model, and the result is spectacular and consistent performance day after day. Unlike older forms of insulation, FireTil securely traps in the heat and does not allow it to escape, providing the most from each BTU. Energy- efficient FireTile• combustion chamber. Like all Hayward products, the H- Series line is designed to the most exacting standards of any pool system. You will be equally impressed with the appearance and user- friendliness as you are with their performance, With the H- Series, Hayward delivers the complete package. Which makes owning an H- Series heater as enjoyable to your senses The digital LED control panel makes temperature programming and diagnostics fast and easy. Hayward's most advanced technologies have been incorporated into each of the Electronic heaters. For example, our Direct Spark Ignition is dependable under windy conditions — keeping the temperature consistent and your fuel costs down. Extend the warmth of your hospitality with the addition of a fuel - efficient, digitally precise system that will transform the element of water into an element of pure enjoyment. Common Features of Our Electronic and Induced Draft Heaters The digital LED control panel makes temperature programming and diagnostics fast and easy. Electronic Features Include: Hayward burners — tough, durable and easily accessible. • Digital LED Control Panel for Simple and Accurate Read -outs and Settings • Reliable Direct Spark Ignition • Patented Non - Corrosive Polymer Headers • High - performance Flow Control Management • Energy- efficient FireTile Combustion Chamber • CPVC Plumbing Connections Reduces Installation Time and Cost • "V" Groove Finn Plate Provides Fast Heating with Virtually No Condensation • High- quality Eugenox Burner System fir• •:• R i MILLIVOLT HEATERS The millivolt system is the right choice for budget - oriented pool and spa applications, helping to extend your pool season and enhance your pool experience. Millivolt Features Include: • Manual Control Panel • Push - button ClickliteTM Ignition • Patented Non- Corrosive Polymer Headers • High - performance Flow Control Management • Energy- efficient FireTile Combustion Chamber • CPVC Plumbing Connections Reduces Installation Time and Cost • •V" Groove Finn Plate Provides Fast Heating with Virtually No Condensation • High - quality Eugenox Burner System Morsel Spa Tub Size in Gallons 200 300 400 500 600 700 800 900 1000 Time in Minutes to Raise Spa Tub Temperature 30'F C11400 j 9 14 19 23 28 33 37 Gas 47 11350 11 16 21 27 Flue Outlet flue Pipe Stack Height Heater Connection 11300 Model BTU, Hr. Width Depth Height Diameter Diameter D11I IMVVS Weight (lbs.) at Heater 11400* -. 400,000 35'i4" 27 28 "2" 9" 10" 31'; 19h" 200 lbs. 56 11350 - 350, 00 32' 2" 27',' " 28 i 9" 10" 62 75 183 lbs. " 11300 300,000 29'>>" 27','_" 281 2" 8" 9" 30'+" 17'; 157 lbs. 11250* 250,000 27" 27'i2" 28' - " 7" 7" 28'2" 17';+" 144 lbs. 11200 200,000 24'/2" 27'/ " 28'2" 7" 7" 28'i 15'/ <" 141 lbs. 11150 150,000 21';'4" 27''2" 28'2" 6" 6" 22',' 14" 131 lbs. Morsel Spa Tub Size in Gallons 200 300 400 500 600 700 800 900 1000 Time in Minutes to Raise Spa Tub Temperature 30'F C11400 j 9 14 19 23 28 33 37 42 47 11350 11 16 21 27 32 37 43 48 54 11300 1 19 25 31 37 44 50 56 62 11250 15 22 30 37 45 52 60 67 75 11200 19 28 37 47 56 66 75 84 94 11150 25 37 50 62 75 87 100 112 125 Selecting the correct size H- Series heater For Your Swimming Pool Determine your pool's surface area in square feet: Area = (A +B) x L x .45 Locate in the table below, the surface area equal to or just greater than the pools surface area, read to the left and select the appropriate 11- Series model. For indoor pool installations, divide the pool's surface area by 3. Recommended H- Series Model Table is based on a 30'F temperature rise, 3'/= MPH average wind velocity and elevation of up to 2,000 feet above sea level. Specifications and Dimensions 11- Series Heaters are available in a comprehensive range of BTU sizes and options, including 1'/2" and 2" water connections, millivolt and electronic temperature control, and natural or propane gas. All units are certified by the American Gas Association and carry Hayward's exclusive warranty. *The H400 and 11250 are available in induced draft, millivolt and electronic temperature control models. The Hayward H- Series Family of High - performance Heaters M illivo l t 2003 Hayward Pool Products, Inc. 11503 Area= RxRx3.14 Electronic A Area =LxW Induced Draft For Your Spa or Hot Tub Determine your spa capacity in gallons (Surface area x average depth x The reference table lists the time required in minutes to raise the temper- ature of the spa,'hot tub by 30'F. Locate in the table below the spa,'hot tub size in gallons equal to or just greater than the spa,'hot tub size in gallons. Select the desired time to raise the spa hot tub temperature 30'F, read to the left and select the appropriate H- Series model. This guide can be adjusted for other temperature rises. For example, if you desire a 15'F increase in temperature, simply divide the time for 30 F rise by the ratio of 30,15, or 2. Note: Heat losses and/of heat absorbed by spa walls or other objects will add to the time it takes the spa to heat up. Spa sizing is based on an insulated and covered spa. Always cover your spa or hot tub when not in use to minimize heat loss and evaporation. Recommended H- Series Model Www.haywardnet.com H- Series Heaters feature water connections that are fully compatible with pre- existing installations. HAYWARD Surface Area dgIllijllP 1200 11350 1050 11300 900 H250 750 11250 750 11200 600 11150 450 Selecting the correct size H- Series heater For Your Swimming Pool Determine your pool's surface area in square feet: Area = (A +B) x L x .45 Locate in the table below, the surface area equal to or just greater than the pools surface area, read to the left and select the appropriate 11- Series model. For indoor pool installations, divide the pool's surface area by 3. Recommended H- Series Model Table is based on a 30'F temperature rise, 3'/= MPH average wind velocity and elevation of up to 2,000 feet above sea level. Specifications and Dimensions 11- Series Heaters are available in a comprehensive range of BTU sizes and options, including 1'/2" and 2" water connections, millivolt and electronic temperature control, and natural or propane gas. All units are certified by the American Gas Association and carry Hayward's exclusive warranty. *The H400 and 11250 are available in induced draft, millivolt and electronic temperature control models. The Hayward H- Series Family of High - performance Heaters M illivo l t 2003 Hayward Pool Products, Inc. 11503 Area= RxRx3.14 Electronic A Area =LxW Induced Draft For Your Spa or Hot Tub Determine your spa capacity in gallons (Surface area x average depth x The reference table lists the time required in minutes to raise the temper- ature of the spa,'hot tub by 30'F. Locate in the table below the spa,'hot tub size in gallons equal to or just greater than the spa,'hot tub size in gallons. Select the desired time to raise the spa hot tub temperature 30'F, read to the left and select the appropriate H- Series model. This guide can be adjusted for other temperature rises. For example, if you desire a 15'F increase in temperature, simply divide the time for 30 F rise by the ratio of 30,15, or 2. Note: Heat losses and/of heat absorbed by spa walls or other objects will add to the time it takes the spa to heat up. Spa sizing is based on an insulated and covered spa. Always cover your spa or hot tub when not in use to minimize heat loss and evaporation. Recommended H- Series Model Www.haywardnet.com H- Series Heaters feature water connections that are fully compatible with pre- existing installations. HAYWARD Simply stated, the induced draft system provides lavish comfort, control, and a state -of- the-art heating environment that is impervious to wind and other environmental factors. In addition, the Pre -mix burners provide an environmentally friendly system with the highest efficiency rating in the industry. Our "V" Groove Finn Plate Heat Exchanger —the future of heat exchanger technology. Induced Draft Features Include: • Digital LED Control Panel for simple and Accurate Read -outs and Settings • Hot Surface Ignition Eliminates the Need for Pilot Lights • Consistent Induced Draft Blower • Patented Non - Corrosive Polymer Headers • High- performance Flow Control Management • Energy- efficient FireTile Combustion Chamber • CPVC Plumbing Connections Reduces Installation Time and Cost • "V" Groove Finn Plate Provides Fast Heating with Virtually No Condensation • Environmentally Friendly Pre -mix Low NOx Burner System Selecting The 1 that is right for you. The Hayward H- Series line of pool and spa heaters incorporate the most advanced technology to provide lavish comfort, energy - efficient operation and long lasting dependability. When you select the H- Series that meets your specific needs, you'll be turning up the heat in confidence, with the precision, comfort and control you've come to expect from the leader in pool systems. H- Series Features 1'ind Management System Thermal Efficiency Control Panel Burner System Eugenox Eugenox Pre -Mix Low NOx Pre-mix burners are envi- ronmentally friendly and efficient Ignition System Standing Pilot Direct Spark Hot Surface More reliable lighting Heat Exchanger Finn Plate Finn Plate Finn Plate Heats quickly and consistently Patented Polymer Yes Yes Yes Reliable rust -- resistant Headers and Stainless water path Steel Tube Sheets Flow Control Thermal Control Valve Thermal Control Valve Thermal Control Valve Regulates water flow to Management System heat efficiently and elimi- nates condensation Combustion Chamber 1" FireTile'° 1" FireTile' 1" FireTile State - the - art combustion chamber to maximize heat retention and stretch energy dollars \ arranty High Wind Stack 80 -82°'o Single Thermostat 2 Years Parts 5 Years FireTile` 10 Years Polymer Headers High lA ind Stack 80 -82 %b Digital Thermostat 2 Years Parts 5 Years FireTile" 10 Years Polymer !leaders INDUCED DRAFT Induced Draft Blower 84% Digital Thermostat 2 Years Parts 5 Years FireTile' 10 Years Polymer Headers ADVANTAGE Consistent performance in the harshest environments More heat for less money Simple setting of temper- ature and on board diagnostics Peace of Mind SITE PLAN Scale: 1 in = 10ft. Oin. H 0 Z GATES TO BE SELF CLOSING AND SELF LATCHING x 1101. BRICK PAVER PATIO u!L14FL GFI SEPTIC TA' K WATER METER I OOL REQUIREMENTS: SELF CLOSING/ SELF - LOCKING GATES REQUIRED ENCE: 4' HIGH (MIN.) ND NON - CLIMBABLE IF NEIGHBORS REMOVE FENCE/ WALL - OWNER MUST REPLAC WITH A 4' FENCE ON OWNER'S PROPERT" EXISTING CONCRETE RESIDENCE 3Nfl ALN3dO d 7I 9L 31 ft 6i LEGAL DESCRIPTION: LOT 7 AND THE EAST 1/2 OF LOT 8 DADE COUNTY FL +�f r EXISTING ELECTRIC MEI t.R 23 ft 9 in. EXISTING 200 AMP P BLOCK 67 OF MIAMI SHORES SECTION 3. PLAT BOOK 10 PAGE 37 RECORDS OF ELECTRIC SLIDING GATE R x r Z m EXISTING 4' HIGH CL FENCE WTH - - -- SELF CLOSING AND SELF LATCHING GATE 54" GATES TO BE SELF CLOSING AND SELF LATCHING SITE PLAN SEALED FOR POOL LOCATION ONLY POOLDESIGN.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941 -1124 infolgswimmingpoo Iplan.com MARS POOLS 1000 E. ATLANTIC BLVD. POMPANO BEACH, FL. 33060 SUITE 11 (954) 214-2844 www.marspools.com O'CONNOR RESIDENCE 746 NE 95TH STREET MIAMI SHORES, FL 33138 A ' 77)4(-..,./ 4 _,-- J jn es Hanskat, P.E. �1 P.E. #49801 1000 E. Atlantic Blvd. Suite 200 Pompano Beach, FL 33060 LAYOUT PAGE POO LOCATION ELEVATIONS VERIFY ALL DIMENSIONS WITH ACCURATE SURVEY SCAt 1/4" = 1 FOOT IF W ER SOURCE IS A PRIVATE WELL PRE FILTE WATER TO FILL POOL ALL ETALLIC ITEMS WITHIN 5' -0" OF WATER'S EDG POOL TO BE BONDED WITH #8 SOLID INSULATED WIR listed) FROM POOL STEEL. ALL GROUND WIRES CONNE TO STEEL WITH BRASS GROUND LUGS G.F.I, OUTL MIN. AND 20' MAX. FROM POOL IF EN( AROU GATE PROV STET L OVERLAP 48 TIMES DIAMETER EST BOSH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENCY. ALLOW MIN 10' HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO POOL WATER. DEC NO FOR PR AN PR FL PR BAI CAI THI DO ANI NO THI ALL PIPING TO BE PVC SCHEDULE 40 MIN AN ALL PRESSURE PIPING AND MAIN D PI ING MUST BE PRESSURE TESTED PRI GU ITE (CONCRETE) S IMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BRAKER LOSURE IS REQUIRED ADD SCREEN OR FE D POOL OR PROPERTY TO BE SELF CLOSING AND SELF LATCHING DE DOOR AND WINDOW ALARMS AS REQUI" SHALL HAVE A SLIP RESISTANT FINISH ITH HARP EDGES AND BE POSITIVELY SL 'PED DRAINAGE VIDE WEEP HOLES AND DEWATERING P MPS ANY OTHER METHODS NECESSAR TO VENT THE POSSIBILITY OF THE • OOL ATING DUE TO HYDROSTATIC U•LIFT SSURE.WHEN THE POOL IS EMPTY. KFILLING OF THE POOL SHALL BE EFULLY TO ASSURE THAT NO DAMA PIPING OCCURS AND BACKFILLING SHA E WITH CLEAN SOIL FREE FROM ORG DEBRIS AND SHALL BE COMPACTED SO VOIDS EXIST PROVIDING A FIRM BEARIN DECK THIS IS NOT A DIVING POOL, LOCATE POOL RETURNS DOWN 18' MIN. BELOW THE POOL BEAM Pd OLDESIG.V. NET OF (u.l. TED T 10' 12 ft. 6 in. R 4-6" R 4-0" R 4' -6" \ R 3 -6" • ONE E TO L BE NICS HAT FOR MUM RAIN TO 12 ft.8in. 26 ft. 11 in. co N (O' N 1 ft. 7 i 5 ft. 11 in 12 ft .4in. i 4 ft . R 4-0" 3 ft. 0 in. G -� —� ■ co R . r osTI e - Hanskat, P.E.- P.E. #49801 1 X 00 E. Atlantic Blvd. Suite 200 Pompano Beach, FL 33060 POOLDESIGN.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33080 (954) 941.1124 i nfo©swi m mi ng pool plan. corn MARS POOLS 1000E ATLANTIC BLVD. POMPANO BEACH, R. 33060 SUITE 11 (954) 214 -2844 www marspools com ' O h O'CONNOR RESIDENCE 748 NE 95TH STREET MIAMI SHORES, FL 33138 02- 01 -05� PLUMBING PAGE Sc le: 1/4" = 1' -0" DO NOT EMPTY SWIMMING POOL WIT OUT FIRST RELIEVING HYDROSTATIC PRESSURE BY UTILIZING A PUMP ATTACHED TO UND = RPRESSURE LINE. POOL ESIG:V. 1 -1/2" VENT LINE 2" UNDERPRESSURE LINE N 2" UNDERPRESSURE LINE FOR DEW ATERING DEEP END EXIT 1 SWIMOUT (SEE DETAIL) 1.1/T CLEANING FITTING W/COVER INSTALLED 8" TO 12" BELOW WATER LINE 1 -1/2" VENT LINE 1 -1/2" VENT LINE 10 ft. 0in. 10 ft 12 ft. 8 in. 12 ft. 6 in. 1 -1/2" SPA RETURNS 2" SPA AIR LINE 2" SPA JETS SPA LIGHT 2" SPA MAIN DRAIN 2" SPA MAIN DRAIN CONDUIT FOR SPA SWITCH POOL LIGHT 2" MAIN DRAIN LINE 2" CLEANER LINE 2" RETURN LINES 2" SKIMMER LINE +12" BRICK PAVER PATIO co ■ 1,, , .2- 0 H es'- ns P.E. P.E. #49801 X00 E. Atlantic Blvd. Suite 200 , Pompano Beach, FL 33060 POOLDESXG 1000 EAST ATLA(TIC BLVD SUITE 100 POMPANO BEACH FLA 33060 (954) 941.1124 intogswimmingpool.lan corn MARS POOLS 1000 E ATLANTIC BLVD POMPANO BEACH, Ft, 33080 SUITE 11 (954) 214 -2844 www.marspools com O , O'CONNOR RESIDENCE 1 :, 748 NE 95TH STREET MIAMI SHORES, FL 33138 02 -01 -05 E _ECTRICAL DETAIL 1 FPL SERVICE METER G.F.I. OUTLET E7�ISTING —" 15 ampr'l PANEL I, 2camp� AMP 20 am T. GROUND TOGGLE — SWITCHES 3 #12s IN 1/2" CONDUIT BL•WER SPA HP 2HP 10.4 AMP 10.4 AMP 2 POOL RETURN 11— HLORINATO ILTER PAD DETAIL L gm 9 ,SWAY VALVE CHECK VALVE Ii 1.5 HP PUMP 75 GPM 3 -WAY VALVE 1Q w rn CHECK ' VALVE 2 HP PUMP 100 GPM ce L /I JB 5' MINIMUM 1ROM WATER SIDE VIEW NTS 1 DEGREES MAX. ANGLE FROM PLUMB PO LDESIGN.,ArET POOL 1.5HP 8 AMP 3 -WAY VALVE 3 #12sIN1/2" .1/' CONDUIT 12v TRANSFORMER CHLORINATOR #8 AWG INSULATED/ - COPPER WIRE GROUND TO POOL STEEL 2" SPA RETURN SPA MAIN DRAINS DECK DETAIL UNCTION BOX locate 8" min. above water line. CEMENT EDGE LIGHT CORD (IN CONDUIT) #8 AWG INSULATED - COPPER WIRE EPDXY COATED (IN CONDUIT) — .- - - amy -- • — ALL METALLIC ITEMS WITHIN 5' -0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (u./. listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS G.F.I. OUTLET 10' MW. AND 20' MAX. FROM POOL #8 AWG INSULATED COPPER WIRE EPDXY COATED NOTES. 1 P001 EQUPMENT ANCHIRAGE HAS BEEN DESIGNED TO COMPLY WITH F B SECT. 301 13 2. ALL EQUIPMENT SHALL BE PLACED ON A SINGLE SLAB. 31' 8" ANTIVORTEX MAIN DRAIN GRATE SECURED IN PLACE ;sO TOOLS ARE REQUIRED FOR REMOVAL YDROSTATIC VALVE WITH WELLPOINT GRAVEL SUMP STRUCTURAL DETAIL SLOPE DECK 1/8" PER FOOT FROM POOL. L 1 1 COMPACTED FILL 3 min. 3" #3 STEEL 10" O/C HORIZONTAL & VERTICAL f' 0 2HP AIR BLOWER O MA N DRAINS POOL INTERLOCKING BRICK PAVERS �F--- COPING �{ 6 "X6" CERAMIC TILE 2 #3s CONT 18" MIN. FROM TOP OF LIGHT TO WATERLINE ___300 WATT 12v REMOVABLE UL UNDERWATER LIGHT 6" WALLS AND FLOOR CONCRETE - SHOTCRETE-OR GUNITE DIAMOND BRITE FINISH POOL STEEL OVERLAP @ 48 TIMES DIAMETER (4) 5 /8" DIAM. x 4' HILT KWIK BOLTS — (4) 1 /2" DIAM, x 3" HILT1 KW1K BOLTS EQUIPMENT ANCHORAGE DETAIL HEATER 6" CERAMIC TILE TILE�� - � 84 ♦ , DECK L t I ` #3 STEEL C/4 10" O/C HORIZONTAL & VERTICAL SLOPE OF POOL BOTTOM NOT TO EXCEED 1' IN 7' rav SLRnp o 0 0 0 + o ° 0 1, RAISED SPA DETAIL 12" RAISE WITHSPILLWAY PUMP 0 0 0 0 105 SP' ANTI - ENTRAPMENT POOL DETAIL 'ate"?' Me 11 drg max Smooth Troweled Plaster Interior 8" AntiVortex Main Finish Drain Grate Shall Be Secured In Place 6" Thick Walls So That Tools Are Required For Removal 0 0 0 0 4" THICK CONCRETE SLAB VENT LINE TO BE 1ft MIN. ABOVE POOL WATER SPA PUMP: 2 HP .-. IIMIWONIMMIMINt Threaded Plug Hydrostatic Valve W/ WellPoint 0 1 35" 39" 7. W12VSAjLIGHT Antivor1ex Main Drain Covers Screwed Down SPECIFICATIONS POOL SIZE: 18 X 31' PERIMETER: 86 L.F. INLET RETURNS: 4 POOL PUMP: 1.5 HP POOL LIGHT: SAM LIGHT DECK: BRICK PAVERS MARBLE or TILE SPILLWAY 1 m LL 1 -1/7 VENT LINE 24" ■� � t;� Marble ,�� �■.■ ■ ��� Splil 11111 um i Mama memmum ME -VENT IS DESIGNED TO EVACUATE SUCTION IN 3 SEC OR LESS PER FBC 424 -THIS SAFETY VACUUM RELIEF SYSTEM IS A NON - MECHANICAL VENT SYSTEM THAT WILL LIMIT THE TRANSMISSION OF SUCTION AT THE OUTLET TO A 5 MAX. OF 4.5" OF MERCURY PIPE 1 PRESSURE FLOW I SUCTION FLOW SIZE CAPACITY (10FPS) CAPACITY (BFPS) 80 gpm 49 gpm 20" 1D0 gpm 80gpm 2 5" • 150 gpm 110 gpm 3 0" 220 gpm 1 180 9Prn POOL DEPTH: 3' TO 5' GALLONS: 13,000 SPA: 6' X 6' 3 #4 con SPA LIGHT: SAL 8" ANTI - ENTRAPMENT 6 MAIN DRAINS TO HAVE ANSI ASME A112.19.8M ANTI VORTEX COVER POOL MAIN DRAIN DETAIL POOL MAIN DRAINS TO BE INSTALLED 3' APART PUMPING FLOW RATES HP ,FLOW RATE 3/4 hp = 55 gpm 1 0 hp = I 75 gpm 1 5 hp = 1 90 gpm 2.0 hp= 95gpm 2 5 hp = 115 Qom 30 h= 150gpm J 80 TDH THERAPY JETS: 6 CAPTILE EDGE FILTER: CARTRIDGE 225 S.F. POOL MAIN DRAINS: 2 VENT PIPE SIZE i MAX LENGTH 1.112" 29 LF 1.1/2" 40 CF 1 -112" 49 LF 1.1/2" 51 LF 1.112" I 82 LF 1.1/2'" 78 LF BASED UPON STA -RITE MAX -E -PRO SELF PRIMING PUMP .(HYDROSTATIC UPLIFT CALCULATIONS _ T4 TOP OF BEAM (POOL) ELEVATION ' BOTTOM OF POOL ELEV. FLOOD CRITERIAN ELEVATION POOL IN FLOOD HYDROSTATIC RELIEF VALVE II NET HEAD ;\' SLAB THICKNESS = 6" LOAD CALCULATIONS GEN LIGHTING 12,249 ISE X 3 WATT; + 3000 WA POOL PUMP POOL LIGHT GEN APPLIANCES AND WATER HEATER SUB -TOTAL 2 AT 100% 2 AT 100% SUB -TOTAL TOTAL FIRST 10 KW AT 100% REMAINDER 34,062 WATTS Q40% TOTAL LOAD OREMAIN DER FACTOR A/C OR HEATING AT 100% TOTAL CONNECTED LOAD = 33,625 WATTS/240V 6,747 WATTS 9,747 WATTS 28,000 WATTS 37,747 WATTS 6,090 WATTS 225 WATTS 6,315 WATTS 44,062 WATTS 10,000 WATTS 13625 WATTS 23,625 WATTS 10,000 WATTS 140 AMPS SURFACE AREA: 436 S.F. 11.12 5,12 8.0 3.12 -2.0 1.12 TURNOVER RATE: 3 HOURS II SPA MAIN DRAINS: 4 1 HEATER: GAS 400,000 BTU ENCLOSURE: EXISTING CL FENCE SKIMMER: 1 2" VACUUM LINE W/ SAFETY COVER: 1 SWIMOUT DETAIL DESIGN PER FLORIDA BUILDING CODE 424.2 INCLUDING BUT NOT LIMITED TO 424.2.6.6 ENTRAPMENT PROTECTION FOR SUCTION INLETS 424.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS GENERAL NOTES STRUCTURAL 1) PLANS DESIGNED PER 2001 F B C, 2) THE SITE SHALL HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1200 PSF 3) THE FOLLOWING iR DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPO1.TING A POOL AND DECK OF SIMILA SIZE AND DEPTH. IF CONnITIoNS DIFFER F.R)M CDNDITIO.J3 3'LCIFIED ABOVE, ',HIS ENGINEER SHA_L BE NOT ED PRIOR TO FURTHER CONSTRUCTION OF THIS PRO„ ED 4) AL'. CONCRETE SI:ALL CONFORM T.) A C.1 3 CONCRETE HALL HA A I1INIMUM CD'A'^.ESSIVE STRENCTH CT 3.000 P3I FO,t Pl EUMATICALI Y PLACED CONCRETE (GUNITEISHOTCRETE) AND 2,500 P; t FOR POL'R3D D■I "CRETE. • 5) ALL REINFORCING oTEEL SHALL BE INTERMEDIATE GRADE DEF')RMED BARS OR NEW bLLU, J!EAL CONF.A.MINO TO A. T.S.M. -15. STEEL SHALL BE BENT LAPPED, AND PLACED N ACCJRDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. PIPING. 1) ALL POOL PIPING SHALL BEAR THE N S.F. -PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V C. MIN. POOL PIPING TO COMPLY WITH F B.0 POOL , EQUIPMENT TO APPLY TO F B C. 2) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE S NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER LL MEET ALL DISPOSAL SYSTEM AND SH REOUIREMEi �iN F B C. MARS POOLS 1000 E. ATLANTIC BLVD. POMPANO BEACH, FL. 33060 SUITE 11 (954) 214 -2844 www marspools com /Nor skat, P.E. P.E. #49801 1000 E. Atlantic Blvd. Suite 200 .� - Pompano Beach, FL 33060 r POOLDESION.NL'I' i 1000 EAST ATLANTIC BLVD, SUITE 100 POMPANO BEACH FLA 33060 (954) 941 -1124 infogswimmingpoolplan corn 748 NE 95TH STREET MIAMI SHORES, FL 33138 O'CONNOR RESIDENCE ATES TO BE SELF CLOSING AND SELF LATCHING LDESIGN..VET SITE PLAN Scale: 1 in = 20ft. Oin. A X 14 ft.7in 10 ft.2in — WATER METER y5 ft . PROPERTY LINE EXISTING CONCRETE RESIDENCE 13ft.8in POOL tli ClLt stitENTS: SOY-CLOSING/ SELF - LOCKING GATES REQUIRE FENCE: AND NON-CLIMBABLE ( (MIN.) IF NEIGHBORS L, R MUST RE FENCE/ WALL, REPLACE WITH A 4' FENCE ON OWNER'S PROPERT ELECTRIC SLIDING GATE EXISTING EL =CTRIC METER EXISTING 20C AMP PANEL L 9 ft. 5 In, EXISTING 4' HIGH CL FENCE WITH .4-- SELF CLOSING AND SELF LATCHING GATE 54" c GATES TO BE SELF CLOSING AND SELF LATCHING ELF- LOCKING T ES REQUIRED 4' HIGH (MIN.) NON - CLIMBABLE IF Nf_ ... OR z REMOVE FENCE/ WALT (; ,` i<-.1. 4. MUST REPLACE FENCE ON € ROPERTY SITE PLAN SEALED FOR POOL LOCATION ONLY LEGAL DESCRIPTIOIN: RECORDS OF DADE COUNTY FL r LOT 7 AND THE EAST I/2 OF LOT 8 BLOCK 67 OF MIAMI SHORES SECTION 3. PLAT BOOK 10 PAGE 37 OUBKIC 7e. ( II '1/5411 es/1i nskat, P.E. 0 E. Atl c Elv S 20 / ' 1- 1 ,Pompano Beach, FL 33060 POOLDESIGN.NET 1000 EAST ATLANTIC BLVD SUITE 100 POMPANO BEACH FLA 33060 (954) 941.1124 in f•4r swimmingpoolPlan.com MARS POOLS 1000 E ATLANTIC BLVD. POMPANO BEACH, FL. 33060 SUITE 11 (954) 214 -2844 wwoe marspools con, O'CONNOR RESIDENCE 748 NE 95TH STREET MIAMI SHORES, FL 33138 ..,egiffeitedigeig rei A .•••••"-* 77,•-••■•• 777,4: - • .14 `74 b Ot.4,.. a § y / '.... -rO p G K, .>i 1 Sy. .x�. 11) V. A. / .t.112. 2 - 1 ` — Top.- It St/AS P6+-3 1"' v? +J - 1 1 __ _ 1 L.— d E w/ 2. - '( i 't IS (..r T> eYti 1 . ist� - n ' ti t:: c a a 1'7._I grit' - IS w ; s r . . --s W A ' I tr. t. ;-'" 1 t3 t'a C1 V C +r. c° f i=• . �. } ;� {, S o a ty r t Ca C.) 2. i+ __sr V ,t c'+ 113 - r te.. rXYrT `1.R)•" Art,11 IY • 4 • -_10 4r. s;, . G ti ; 4. - � • N.rs'110.+arcki - dr3.14 - 1(-1(0 PL c\S ? twaTZS3M1�! rc• Hfc- J! GR. J�f�` Jf.' w .:4'.kA/i<9M'(A!''fl";�42�.7+61 L.'b.'r r'..tiaS !u�`A.f+^ t rt . e GR+.a..,, r 2; t. e .Lac t- i :4 t) t;,:! ? °• 2,1 to P.T. Pr- 0/'tz' '0J :A "eta + ; P.. V.& os.,�. .'it T !� aoc) 11) K r dw, N'f f ��:- Gnt� a-... s�^ �-++: r r. �.ii�n:r+..��n'x.:�+ au+.�w.r.- . �aa..�..:.e REMARKS: COMPLIANCE WITH THE SOUTH BY MIAMI SHORES 4`t+ H E r i SUB CONTRACTOR ING REGULATIONS WHETHER OR w 1$ re n'o( { t L .1•M :IM+*..' V.-Y., . ar ''rrr.+e- 4�..rv.r<_.nlfM.o.•o�s IsX T(VI; sr*i;.S 1 S STk 4L fi +t, 1' 3 #. sr 1 t \If Z. CLQe3‹.tt ,SA�`1e1 511 .Y�. FIRE OEPAR I PUBLIC WORKS POLICE 0 EPARTF�EiI:_ . BUILDING DIRECTOR PLANNING & ZNI ,G , nature APPROVAL FINAL: THESE PLANS ARE APPROVE ) f)R ISSUANCE A BUILDING PERMIT [,t._Wf }1 NO VARIA r r.' I=1 ."�i N VARIANCE( L1STE .. , C �) 0 i REMARKS NO OTHER DE':'IATIO S FR1 !+�f + RDINANCES WILL BE Pe• „S� i 6UttDIN AND ZONING W it F.;.'t SPE. L STED BELOW. WIALL OTHE" A ?PI IC.4B' E S (' 1 E , ` :D �0U.ITY IAWS Ml.� : E COMPLIED TIU,BY f�LL PARTIES. - 7 Autf-o.1'e Date . ,ti, 1 ;,� ► :t: :.5 ADOPTED - Nor SPECIFICALLY INDICATE � I N NAEIM, /xr - .sy: mtex1. UMW" bil i4,1, 11.1d. e, rieheDawe VIVAM1e.0riarY2 y - itt11/17i!vxlIYeflR WINe" .0'•01•f+% Nok.,►1er.wv •Mrrwfffricyn _ /At , 4 - lip �• �J. tiu'1 cj 01014 e► V 1 `at> g . 31' 0 6` 1 r z. 0 V y 4 y 4 .) s y - �9N °t L a" xv` � 4 d !- 0 r Q. , -- -1 : d -. c j _ d� `). 0 c `h 0 t } d Y (,; 9 V y v! E l U` 4 t t� )' 1 d A 0?e��l Q L x 1 4 d Q { ' s o . 1 ti' � � ' , VQ ,A -. 3 9. ?'' 0 -. ,1 h cs y ii N F- -- f- & 1:," 1- s 7 d ti � ".I `� IN ��, n w a F y 1 a IA t� u '� Q c... 4 0 od2 3 F- 2d 4 - ii --' \� 44 i � }. 1 � z '� a 4 � ) to 1 4 � . 4 $ 41 is ! } s 0k U 7 i Z _ ‘.4.s I d � � 1 G 0.. Q t�l' 4 V - � r MI j �. _1 % : IN U 4 4 s L 1 —1 ' %o i -- — 4 _ _... \ N ■ 4. 1 1 ...,, L ,... 1 ,,,,\N, " , , e... \_„..\„,, , ... i _ ik .e- f o 4 s4 Z 4 I Il � Q „ N ti I d kl 0 t.:).:1 t1 r_ s ( S - i . 4 ' N x ti :t) v'► 1 1 4 4 4.3 A x _ f L 4 -•IIhE ^- r r I J 0 ' 3 0 :"7.4 �d913 nnrm11i 11 - -.. . .- v ov, q,d 3 X4 e s& • d Ff i 1 Eirs " .;;, ,_. .,,,, ,. 1 4 or F PI ri to 2 • . r ' ' il ' ' 'T �• �J. tiu'1 cj 01014 e► V 1 `at> g . 31' 0 6` 1 r z. 0 V y 4 y 4 .) s y - �9N °t L a" xv` � 4 d !- 0 r Q. , -- -1 : d -. c j _ d� `). 0 c `h 0 t } d Y (,; 9 V y v! E l U` 4 t t� )' 1 d A 0?e��l Q L x 1 4 d Q { ' s o . 1 ti' � � ' , VQ ,A -. 3 9. ?'' 0 -. ,1 h cs y ii N F- -- f- & 1:," 1- s 7 d ti � ".I `� IN ��, n w a F y 1 a IA t� u '� Q c... 4 0 od2 3 F- 2d 4 - ii --' \� 44 i � }. 1 � z '� a 4 � ) to 1 4 � . 4 $ 41 is ! } s 0k U 7 i Z _ ‘.4.s I d � � 1 G 0.. Q t�l' 4 V - � r MI j �. _1 % : IN U 4 4 s L 1 —1 ' %o i -- — 4 _ _... \ N ■ 4. 1 1 ...,, L ,... 1 ,,,,\N, " , , e... \_„..\„,, , ... i _ ik .e- f o 4 s4 Z 4 I Il � Q „ N ti I d kl 0 t.:).:1 t1 r_ s ( S - i . 4 ' N x ti :t) v'► 1 1 4 4 4.3 A x _ f L 4 -•IIhE ^- r r I J 0 ' 3 0 :"7.4 �d913 nnrm11i 11 - -.. . .- v ov, q,d 3 X4 e s& • d Ff i 1 Eirs " .;;, ,_. .,,,, ,. 1 4 or F PI ri to 2 • S33 to - 13 P (1 50' 12. " 11 1 r, k a. , 1 13 3 .9"0' a. sd 10' r i 1 1 0' . N. .tt / 49 al rt.` vo l„, ' 14 r _-' 5 ' 15 o tlk la 19 ao 21 t2 „ 23 • 24 25 . 50 ea ' -I 14 r 2/cc 0' f: G • 10.10' IJIER4DY qEzczizrz .. That the attaced aKETCH of 3UX1EY ver4Ig 74ot 7 the East :1 of Lot 8 Bleak (7 Elar , . 4horea 8ect "r.o. 3 accordicz to the plat_recorcloa tn Plate 10,- Page. 37, Public Rccors of' Dade County,' IP true and corre4 to the best of. hy Yr.0wieeze ol and Dior as recently Sur/eyed and 2latted by he I also I ' - certify that tiere aro no encroachllents., t(o/e; Pi/net S'hor(ncrq fiat*, eecdr(ifrol WE 5 s 1- :ay 1959t Registered La zId Surg4 A. G. ZAVY No. 512 SrALS of FLUIDA 1, P Yhe East 1 of Section o. 3 2ool: IO, Page 6o.0 1 3 r / / li1 /01/7 _ • r C P ' (C■ !C•i 1 4.0 Ito 1 5 0 • 43coA /": ?() SI:otch of.8Lrvay 011 • • Dot O. an till of Lot 7 Dlocl: 67 Niant Shores accordin to the plat tlloroOf rccored 1 i):lat 37, Public accorels of Da) County, Yloria. • ZAPF Mani, 21oria t A .0y r- 'i.aia; r n ? tie► 1�+ c x,.,.. fr.�. ii R se:aJ. .`! b +1 a• Ft K�.v . +s ip -'04 2 e; 1 N.�,ati SITE PLAN Scale: 1 in = 10ft. Oin. uig uz. ✓ a01. ✓ ✓ ✓ - u 0 ✓ ✓ 640 s f ▪ BRICK PAVER PAT ✓ ✓ ✓ ti H , o / `4 UILuv r f Z ✓ m H / / / / ✓ / ✓ / u?zuoL GATES TO BE SELF CLosING AND SELF LATCHING x WATER METER 3NIT AO,I3dONd b GL 488' CHILD SAFETY CLOSING AND SE LATCH AT :4" ABC )C TTTTTTTTrrrrrT rrrTS_z it / Lin I ✓ A C) N N C) Z L ll. .7 rSI Z.2 I T TTTTT TTTTl y . B ✓ ✓ ✓ / / / i ✓ ✓ ✓ ✓ ✓ ✓ ✓ / ✓ C, RESIDENCE m Zoning 2 p 3Nn Al213d0bd 7i GL ENCE Wf SELF LATCHING GA' - E E GRADE 23 ft. 9in 31 ft .6in. LEGAL DESCRIPTION. EXISTING ELECTRIC M R EXISTING 200 AMP PANE c ✓ U, LOT 7 AND THE EAST 1/2 OF LOT 8 777 BLOCK 67 OF MIAMI SHORES SECTION 3. PLAT BOOK 10 PAGE 37 RECORDS OF DADE COUNTY FL ELECTRIC SLIDING GATE ✓ ✓ ✓ / ✓ ✓ ✓ / C) C) 0 Z m EXISTING 4' HIGH CL FENCE 4 SELF CLOSING ANC SELF _ATCHNG GATE 54" GATES TO BE SELF CLOSING AND SELF LATCHING SITE PLAN SEALED FOR POOL LOCATION ONLY 7 - _)�, 7 /James m s Hanskat, P.E. i y 'i P.E. #4 1304 E. Atlantic Blvd. Pompano Beach, FL 33060 POOLDESIGN.NET EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954) 941 -1124 info @swimmingpoolpfan.com MARS POOLS 1000 E. ATLANTIC BLVD. POMPANO BEACH, FL. 33060 SUITE 11 (954) 214-2844 www.marspools.com O'CONNOR RESIDENCE 746 NE 95TH STREET MIAMI SHORES, FL 33138 DATE REVISED 8/15/2005 SITE PLAN Scale: 1 in = 10ft. Oin. KID SAFE POOL NET 77 TTTTTTTTTTTT T "T7 - TT TTTTTTTTTTTTTr Z:Z7 . 11 r 7ft 9in. 23 ft. 9in. 31ft 6in. EXISTING CONCRETE TOP NA TH PAVERS 423 S F EXISTING ELECTRIC M - EXISTING 200 AMP PANG c / M V f GATES TO BE SELF CLOSING AND SELF LATCHING i 9 14 640 s. f. PAVER PAT UIL 1J bL OR -. • WATER METER 3Nn AL2d3dOLld 71 SL 3Nn A .63clOLd 14 SL RESIDENCE LEGAL DESCRIPTION: LOT 7 AND THE EAST 1/2 OF LOT 8 BLOCK 67 OF MIAMI SHORES SECTION 3. DADE COUNTY FL I ELECTRIC SLIDING GATE z m EXISTING 4' HIGH CL FENCE NTH 4 SELF CLOSING AND SELF LATCHING GA'E 54" GATES TO BE SELF CLOSING AND SELF LATCHING POOLDESIGN.NET 1000 EAST ATLANTIC BLVD. SUITE 100 POMPANO BEACH FLA 33060 (954)941 -1124 info@swimmingpoolpIan.com PLAT BOOK 10 PAGE 37 RECORDS OF MARS POOLS 1000 E. ATLANTIC BLVD. POMPANO BEACH, FL 33060 SUITE 11 (954) 214 -2844 www.marspools.com O'CONNOR RESIDENCE 746 NE 95TH STREET MIAMI SHORES, FL 33138 DATE REVISED 8/30/2005