443 NE 94 St (9)MIAMI SHORES VILLAGE, FLORIDA
BUILDING ❑ n
Date 19 (.
ELECTRICAL ❑ �� ��
PLUMBING ❑ PERMIT N? 9347 Contractor's
ROOFING License No.
Owner of
Building
❑ Work to be performed under this Permit
Architect
Contractor ;7
or Builder
Legal Lat
Description I I B1.
Address of > - /2
Building
CONTRACTOR or BUILDER
Subdi-
vision
Sq Ft
Value of
Project
This permit is granted to the contractor or builder named above to construct the building or to install the equipment or device described in the applica-
tion herefor in strict compliance with all ordinances pertaining thereto and with the understanding that the work will be performed in compliance with any
plans, drawings, statements or specifications that may have been submitted to and approved by the proper municipal authorities. This Permit may be revoked
at any time if the work is not done in compliance with such ordinances or if the plans are changed without authorization. A further condition upon which this
permit is granted is the understanding that the contractor or builder named above assumes the responsibility for a thorough knowledge of the ordinances and
regulations pertaining to the work covered hereby whether shown on the plans or drawings or in the statements or specifications and that he assumes respon-
sibility for work done by his agents, servants or employees.
Signed t (INSPECTOR) BY
In consideration of the issuance to me of this permit I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village.
In accepting this permit I assume responsibility for all work done by either, myself, my agent, servant or employee.
/BY / F " %
11 Amount of
Permit $
AUTHORITY
eler ®offing SuprAy
3700 Northwest 62 Street, Miami, FL 33147, 305 - 633 -7100, FAX 305 - 633 -9974
DADE COUNTY CODE APPROVAL
VALID FROM MARCH 14,1994 - MARCH 14,1997
PIONEER CONCRETE TILE
"MORTAR SET APPLICATION"
2 PIECE BARREL
SPANISH "S"
9" FLAT
"NAIL -ON APPLICATION"
HACIENDA
SHAKE
SLATE
RUSTIC SHAKE
SPANISH "S"
REGAL
9" FLAT
(PAGE 1 - 23)
METRODADE
MIN
Pioneer Concrete Tile
1340 SW 34th Avenue
Deerfield Beach, FL 33442
Your application for Product Approval of Pioneer Concrete under Chapter 8 of Metropolitan Dade County Code
governing the use of Alternate materials and Types of- Construction, and completely described in the plans,
• specifications and calculations as submitted by Construction Research Laboratory, Inc. and Professional Service
Industries, Inc., has been recommended for acceptance by the Building Code Compliance Office to be used in Dade
County, Florida under the Specific Conditions set forth in pages 2 et seq. and in the Standard Conditions detailed on
page 3.
The Approval shall be valid for a period of three years. The Office of Code Compliance reserves the right to require
retesting of this system within the first two years of the approval should any amend is to the S•uth Florida
Building code be enacted affecting this component or roof system.
ACCEPTANCE No: 94- 0309.04
EXPIRES: Mnq 1 4 1997
PRODUCT CONTROL NOTICE OF ACCEPTANCE
* *PLEASE NOTE **
THIS IS THE COVERSHEET, SEE ADDITIONAL PAGES FOR SPECIFIC
AND GENERAL CONDITIONS.
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Department and approved by the Building Code Committee to be used in Dade County, Florida under
the conditions set forth above.
APPROVED: MAR 1 4 19 9 4
THIS PRODUCT CONTROL APPROVAL SUPERSEDES PRODUCT _ -
CONTROL APPROVAL 90- 0711.02R, #90= 0711.01, #90 0711.03 &
92- 1114.01, #94- 0106.11 - _ -
0000011.
METROPOLITAN DADE COUNTY, FLORIDA
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE DEPARTMENT
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375-2908
it Diamond, R.E.
oduct Control Division
Supervisor
Charles Danger
Building Code Compliance Department
Metropolitan Dade County •
•t
METRO METROPOLITAN DADE COUNTY, FLORIDA
Applicant
Pioneer Concrete Tile
1340 SW 34 Avenue
Deerfield Beach, F133442
Category:
Sub - Category;
Type;
Sub -Type
Product Control Notice of Acceptance
Roofing System Approval
Prepared Roofing
Tile
Nail - on/Mortar-Set
Concrete
Contact
Dave Snyder, Gary Reed
1340 SW 34 Avenue
—. Deerfield Beach, Fl 33442
(800) 624 -4152
System Description
00
METRO -DADE FLAGLER BUILDING
BUILDING CODE COMPLIANCE DEPARTMENT
SUITE 1603
METRO -DADE FLAGLER BUILDING
140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
(305) 375 -2901
FAX (305) 375 -2908
Product Control It 9 4
Approval Date:
Expiration Date: MAR 1 4 1997
Pioneer Concrete Tile is a domestic manufacturer of extruded concrete roof tile with manufacturing plants stretching
from theWest Coast to the Southeast. Products are fabricated from Portland Cement, placticizer, iron and chrome
oxides, and blended aggregates. Tiles are available in two profiles, and seven varietys for nail -on systems including
'Hacienda', 'Rustic Shake', 'Spanish S', 'Shake', 'Slate', Regal and '9" Flat. Tiles are also available in three varietys
for mortar-set application. All profiles are available in a variety of colors, out of which are shown in sales
brochures.
Pioneer tile is fabricated with a wide ridged and grooved sidelap providing a water channel at veritical joints. The
ridged sidelaps provide a self aligning function, creating a uniformity in appearance.
Matching trim pieces are manufactured for all profiles and form a part of-all Product Control Approvals. Pioneer
markets a full tile system including all accessories required to construct a tile system.
Pioneer Concrete Tile produces concrete tile for both nail-on and mortar -set applications. The minimum roof slope
for all Pioneer Roof Tile slope is 2" : 12 ".
Pioneer Concrete roof tiles have been tested in compliance with all South Florida Building Code requirements for
nail -on concrete tile applications.
THIS PRODUCT CONTROL APPROVAL SUPERSEDES PRODUCT CONTROL APPROV
#90- 0711.02R, #90- 0711.01, #90-0711.03, #92- 1114.01, #94- 0106.11
Gil iamond, P.E.
Material
Wood, Nail -on
System Trade Names -
NAIL-ON - MORTAR -SET
Hacienda 2 Peice Barrel
Shake Spanish 'S'
Slate 9" Flat
Rustic Shake
Spanish "S"
Regal
9" Flat
Maximum Design Velocity Pressure
Material Design Velocity Pressure
Wood, Non - insulated psf (See Comments and Limitations)
Maximum Fire Classification
Classification
Class A
- x;00003
Product Control No.: 94- 0309.04
Product Dimensions
Shake or Slate
Hacienda
Rustic Shakes
Spanish "S"
J I
Trade Names of Products Manufactured or
Labeled by Applicant
17V4 "x13"
17W x 13"
17 -1/2" x 13"
17 -1/2" x 13"
. Test Specifications
PA 112
Product Control No
Product Description
Interlocking, high pressure, flat, extruded
concrete tile with a wide ridged and
grooved sidelap; has two cast -in nail
holes.
PA 112 Interlocking, double roll, high pressure
extruded concrete tile with two cast -in
nail holes; has a wide ridged and grooved
side lap.
PA 112 Interlocking, flat with scored surface,
high pressure extruded concrete tile with
a wide ridged and gooved sidelap; has two
cast -in nail holes.
PA 112 Interlocking, Mission S- shaped, high
pressure extruded concrete tile with a
wide ridged and gooved sidelap; has two
cast -in nail holes.
Product - Dimensions
X30 Felt ASTM D 226,
type II
:43 Base Sheet ASTM D 2626
Mineral Surface Cap ASTM D 249
Sheet
Asphalt Primer ASTM D 41
Mopping Asphalt
Flashing Cement
_ Valley Flashing Min. 26 ga, x 16" . ASTM A 525
Drip Edge Min. 26 ga., 2" x ASTM A 525 Galvanized steel drip edge. generic
2"
Wood Battens Min. 1" x 2" for LP - 2
horizontal, 1" x
4" for vertical
_ _ Roofing Nails Min. 12 ga. x 1" ASTM A 641
Trade Names of Products Manufactured by Others
Test Specifications
Saturated organic felt to be generic
used as a nailed anchor
sheet.
Saturated and coated
organic base sheet for
single ply underlayment.
Mineral surfaced asphalt generic
roll roofing.
ASTM D 312, Asphalt for bonding the generic
type III or type mineral surface cap sheet
1V to the base sheet.
ASTM D 4586 Cut bick, asphalt based, generic
fiber - reinforced trowel
grade cement for flashing
and repair applications.
_000005 - . Gil Diamond, ' .E.
Pressure treated wood generic
battens.
Product -
Descripdon
Cut back, asphalt based generic
coating used to facilitate
adhesion of dissimilar
materials.
Galvanized steel valley generic
flashing.
Product Control No..
Manufacturer
generic
Corrosion resis roofii g generic
nails. ' - • - - .. - 4 - - •
. Tin Craps 1vun. i L ga_- x.
1-5/8"
_ 4, _
Tile Nails
Min. 11 ga. • ASTM A 641 _ . • Corrosion resistant nails. generic
Nail heads shall exceed the
size of nail holes in tile.
Hurricane Clip PA 114
Hurricane Clip •
Fasteners
Tile Adhesive
R8 x 2" PA 114
ASTM D 3498 Structural bonding . - Ohio Sealants, Inc.
adhesive for roof tile.
• _a :�
discs. - -
Galvanized , bronze,
aluminum, plastic, or
stainless steel attachment
clip for high windareas.
generic
Compatible fastener for generic
. clip
Test Agency Test Identifier
Construction Research #5750 Wind Driven Rain
Laboratory, Inc. Infiltration Resistance
#5749
#5613
. Test Reports
:5613 Uplift Approvals; Static 04/02/93
Pressure Structural Uplift
Resistance
Professional Service 4395 -00074 Material Properties Test 10/16/91
Industries, Inc. (Water Absorption and
Breaking Strength)
- .
Wind Driven Rain
Infiltration Resistance
Wind Driven Rain
Infiltration Resistance
Product Control No.: t.
Test Name/Report Date
02/26/93
02/25/93
04/01/93
Deck Type 1:
Deck Description:
Slope Range:
System A.
Underlayment
Fastening:
Membrane:
Vertical Battens:
Horizontal Battens:
Roofing Tile:
Maidmum
Aerodynamic
Overttrning Moment
Comments:
03-15 -1994 �9:20(1
Wood, non - insulated
New construction, 19132' or greater plywood or wood plank
2 ":12.' to <4 ":12"
Any approved No. 30 or No. 43 organic anchor sleet Head laps shall be minimum 2",
side laps shall be minimum 6 ".
Nails and tin caps, two (2) rows staggered 12" grid. 6" o.c. at the laps.
A approved mineral surfaced rolled roofing applied in hot asphalt or cold process
cement (See Model Tile Specifications). Head laps shall be minimum 2 ", side laps shall be
minimum 6 ".
Vertical battens. shall be installed on roof slopes of 2':12" to 0":12 ".
Men. 1" x 4" pressure treated lumber. Battens shall be set in a max I/8' thick coniiauous
bed of compatible flashing cement and secured through the sheathing into the top cord of
the truss with approved fasteners. .
Horizontal battens shall be installed on roof slopes of 2':12" ttb <4 ":12 ".
Horizontal battens shall be installed over the vertical battens. Battens shall be spaced to
allow for a 3' minimum head lap, unless an approved headlap configuration which has
been tested for water infiltration is used. Batten size shall be nominal 2' a 2" or 1' x 4 ".
All battens shall be pressure treated or decay resistant lumber and shall be installed in
strict compliance with the mks application instructions and the Metro -Dade
Model Nail -on Tile specification.
The tile system shall be installed in compliance with the Metro Dade County Model
Nail -on Tile Specification (Appendix 'X of the South Florida Building Code), utilizing the
components listed in the Products Listing? set forth in this Product Control Approval.
Applications, as detailed in the test reports, are consistent with the application methods
stated in the execution section of said model specification.
To be Completed by May 30, 1994. Refer to Limitation No. 6.
Systems
Product Control No
For re -roof applications, 15/32" plywood is an acceptable substrate.
.._-000008. - .
305 375 2908
P.02
Deck Type 1:
Deck Description:
Slope Range: - _
System B.
Underlayment:
Fastening:
Membrane:
Vertical Battens:
Horizontal Battens:
Roofing Tile:
Maximum
Aerodynamic
Overtuning Moment:
Comments: -
Wood, non - insulated
New construction, 19/32" or greater plywood or wood plank.
• 2 ":12" to <4":12"
Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ",
side laps shall be minimum 6 ".
Nails and tin caps, two (2) rows staggered 12" grid, 6 "o.c. at laps.
Any self - adhered single -ply underlayment approved by the Chief Product Control
Compliance Officer, installed in strict compliance with the Product Control Approval.
Vertical battens shall be installed on roof slopes of 2 ":12" to <4 ":12 ".
Min. 1" x 4" pressure treated lumber. Battens shall be set in a max. 1/8" thick continuous
bed of compatible flashing cement and secured through the sheathing into the top cord of
the truss with approved fasteners.
Horizontal battens shall be installed on roof slopes of 2 ":12" to <4 ":12 ".
Horizontal battens shall be installed over the vertical battens. Battens shall be spaced to
allow for a 3" minimum head lap, unless an approved headlap configuration which has
been tested for water infiltration is used. Batten size shall be nominal 2" x 2" or 1" x 4 ".
All battens shall be pressure treated or decay resistant lumber and shall be installed in
strict compliance with the manufacturer's application instructions and the Metro-Dade
Model Nail -on Tile specification.
The tile system shall be installed in compliance with the Metro Dade County Model
Nail -on Tile Specification (Appendix 'W' of the South Florida Building Code), utilising
the components listed in the Products Listings' set forth in this Product Control •
Approval. Applications, as detailed in the test reports, are consistent with the application
methods stated in the execution section of said model specification.
To be completed by May 30, 1994. Refer to Limitation No. 6.
For re -roof applications, 15/32" plywood is an acceptable substrate:
•000009 . Gil Diamond, P
Deck Type 1A:
Deck Description:
Slope
System A.
Underlayment:
Fastening:
Membrane:
Vertical Battens:
Horizontal Battens:
Roofing Tile:
Maximum
Aerodynamic
Overtuning Moment:
Comments:
Deck Type 1A:
Deck Description:
Slope Range:
. System B.
Underlayment:
Fastening:
Membrane:
Vertical Battens:
Horizontal Battens:
Roofing Tile:
Ma.xdmum
Aerodynamic
Overtuning Moment:
Comments:
•
•
Wood, non - insulated
New construction, 19/32" or greater plywood or wood plank
4 ":12" to 7 ":12"
Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ",
side laps shall be minimum 6".
Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps.
Any approved mineral surfaced rolled roofing applied in hot asphalt or cold process
cement (See Model Tile Specifications). Head laps shall be minimum 2 ", side laps shall be
minimum 6 ".
Vertical battens are optional for roof slopes of 4 ":12" to 7 ":12"
Horizontal battens are optional for roof slopes of 4 ":12" to 7 ":12"
The tile system shall be installed in compliance with the Metro Dade County Model
Nail -on Tile Specification (Appendix 7C of the South Florida Building Code), utilizing the
components listed in the Products Listings' set forth in this Product Control Approval.
Applications, as detailed in the test reports, are consistent with the application methods
stated in the execution section of said model specification.
To be completed by May 30, 1994. Refer to Limitation No. 6.
For re -roof applications, 15/32" plywood is an acceptable substrate.
Wood, non - insulated
New construction, 19/32" or greater plywood or wood plank.
4 ":12 " to 7 ":12"
Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ",
side laps shall be minimum 6".
Nails and tin caps, two (2) rows staggered 12" grid, 6 "o.c. at laps.
Any self - adhered single -ply underlayment approved by the Chief Product Control
Compliance Officer, installed in strict compliance with the Product Control Approval.
Vertical battens are optional for roof slopes of 4 ":12" to 7 ":12" -
Horizontal battens are optional for roof slopes of 4 " :12" to 7 ":12"
The tile system shall be installed in compliance with the Metro Dade County Model
Nail -on The Specification (Appendix 'W' of the South Florida Building Code), utilizing
the components listed in the 'Products Listings' set forth in this Product Control _
Approval. Applications, as detailed in the test reports, are consistent with the application
methods stated in the execution section of said model specification.
To be completed by May 30, 1994. Refer to Limitation No. 6.
- For re -roof applications, 15/32" plywood is an acceptable substrate.
0 0E010
_ Deck - Type 1B:
Deck Description:
- Slope Range:
System A_
Underlayment:
Fastening:
Membrane:
Vertical Battens: •
Horizontal Battens:
• Roofing Tile:
Maximum
Aerodynamic
Overtuning Moment:
. Comments: -
Wood, non - insulated
New construction, 19/32" or greater plywood or wood•plank
>7 ":12"
Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2
side laps shall be minimum 6 ".
Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps.
Any approved mineral surfaced rolled roofing applied in hot asphalt or cold process
cement (See Model Tile Specifications). Head laps shall be minimum 1 ", side laps shall be
minimum 6 ".
Vertical battens are optional for roof slopes >7 ":12 ".
Horizontal battens shall be installed on roof slopes >7 ":12 ". .
Horizontal battens shall be minimum 1" x 2" treated lumber shall be installed directly to
the deck in a maximum 1/8" thick bed of flashing cement and secured through the
sheathing into the top truss cord with approved fasteners at a maximum rate of 24" o.c..
Spacing shall be in compliance with the Metro -Dade County Model Nail -on Tile
Specifications and the manufacturer's recommendations. The Metro-Dade Specification
shall take precedence.
The tile system shall be installed in compliance with the Metro Dade County Model
- Nail -on Tile Specification (Appendix 'X' of the South Florida Building Code), utilising the
components listed in the Products Listings' set forth in this Product Control Approval.
Applications, as detailed in the test reports, are consistent with the application u,ctnods
stated in the execution section of said model specification.
To be completed by May 30, 1994. Refer to Limitation No. 6.
For re -roof applications, 15/32" plywood is an acceptable substrate:
_.Deck Type 1B:
. Deck Description:
Slope Range: -
System B.
Underlayment:
Fastening:
Membrane:
Roofing Tile:
Vertical Battens:
Horizontal Battens:
Maximum
Aerodynamic
Overturning Moment:
Comments:
• Wood, non - insulated -
New construction, 19/32" or greater plywood or wood plank.
s7 ":12"
Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be minimum 2 ",
side laps shall be minimum 6". .
Nails and tin caps, two (2) rows staggered 12" grid, 6 "o.c. at laps. -
Any self- adhered single -ply underlayment approved by the Chief Product Control
Compliance Officer, installed in strict compliance with the Product Control Approval.
Vertical battens are optional for roof slopes >7 ":12 ".
Horizontal batters shall be installed on roof slopes >7 ":12".
Horizontal battens shall be minimum 1" x 2" created lumber shall be installed directly to
the deck in a maximum 118" thick bed of flashing cement and secured through the
sheathing into the top truss cord with approved fasteners at a maximum rate of 24" o.c..
Spacing shall be in compliance with the Metro -Dade County Model Nail -on Tile
Specifications and the manufacturer's recommendations. The Metro -Dade Specification
• shall take precedence.
The tile system shall be installed in compliance with the Metro Dade County Model
Nail -on Tile Specification (Appendix 'W' of the South Florida Building Code), utilizing
the components listed in the Products Listings' set forth in this Product Control
Approval. Applications, as detailed in the test reports, are consistent with the application
methods stated in the execution section of said model specification.
To be completed by May 30, 1994. Refer to Limitation No. 6.
For re -roof applicators, 15/32" plywood is an acceptable substrate.
00.0012 .
Deck Type 2: Wood, non insulated, mortar set
Deck Description: New construction, 19/32" or greater plywood plank
Slope Range: 2 ":12 to 7 ": 12
System A.
Underlayment: Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be
minimum 2 ",side laps shall be minimum 6"
Fastening: Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps. .
Membrane: Any approved mineral surfaced rolled roofing appliied in hot ashpalt or cold
process cement (see Model Tile Specifications): Head lap shall be minimum 2"
and side lap shall be minimum 6 ".
Vertical Battens: None
Horizontal Battens: None
Mortar/Adhesive Approved mortar shall be used. All tile shall be set in a mortar patty as set forth
in the Model Mortar-Set Tile Specifications. Mortar shall be Type "M" mixed in
ratio set forth in the Products by Others'. Any adhesive application shall be
applied as *et forth in the adhesive Product Control Approval. All tile and
accessories shall be installed in compliance with /system 4'3 of the Dade County
Model Tile Specification.
Roofing Tile:
Maximum Design
Velocity Pressure:
Comments:
Install one of the following profiles: Concrete Barrel, Spanish "S ", or 9" Flat
Concrete. The tile system shall be installed in compliance with the Metro Dade
County Model Mortar /Adhesive -set Tile Specification (Appendix 'X' of the
South Florida Building Code), utilizing the components listed in the 'Products
Listings' set forth in this Product Control Approval. Applications, as detailed in
the test reports, are consistent with the application methods stated in the
execution section of said model specification.
See Limitation No. 6.
For re -roof applications, 15/32" plywood is an acceptable substrate. On slopes
5 ":12" to 6 ":12 ", the first three courses of tile shall be nailed with not less than
one nail per tile. As an alternate, the first three courses shall be applied in
mortar over a single layer of minimum 12 ga. wire mesh with square openings
of not less than 3/8" which is mechanically attached to the deck with not less
than one roofing nail per every 2 ft . For pitches from 6 ":12 to 7 ":12, every
third tile of every fifth course, beginning with the eight course, shall be nailed.
On slopes>7 ":12" all provisions of 'System 1' of the Dade County Model
Horizontal Batten Nail -on Tile Specifications shall apply.
000013
Product Control No.: 94- 0309.04
Deck Type 2: Wood, non insulated, mortar set
Deck Description: New construction, 19/32" or greater plywood plank _
Slope Range: 2 ":12 to 7": 12
System B.
Underlayment: Any approved No. 30 or No. 43 organic anchor sheet. Head laps shall be
minimum 2" side laps shall be minimum 6 ".
Fastening: Nails and tin caps, two (2) rows staggered 12" grid, 6" o.c. at the laps.
Membrane: Any mineral surfaced, self - adhered single -ply underlayment approved by the
Chief Product Control Compliance Officer, installed in strict compliance with
the Product Control Approval.
Vertical Battens: None
Horizontal Battens: None
Mortar /Adhesive Approved mortar shall be used. All tile shall be set in a mortar patty as set forth
in the Model Mortar -Set Tile Specifications. Mortar shall be Type "M" mixed in
ratio set forth in the 'Products by Others'. Any adhesive application 'shall be
applied as set forth in the adhesive Product Control Approval. All tile and
accessories shall be installed in compliance with /system #3 of the Dade County
Model Tile Specification.
Roofing Tile:
Maximum Design
Velocity Pressure:
Comments:
Install one of the following profiles: Concrete Barrel, Spanish "S ", or 9" Flat
Concrete. The tile system shall be installed in compliance with the Metro Dade
County Model Mortar /Adhesive -set Tile Specification (Appendix 'X' of the
South Florida Building Code), utilizing the components listed in the 'Products
Listings' set forth in this Product Control Approval. Applications, as detailed in
the test reports, are consistent with the application methods stated in the
execution section of said model specification.
See Limitation No. 6.
For re -roof applications, 15/32" plywood is an acceptable substrate. On slopes
5 ":12" to 6 ":12 ", the first three courses of tile shall be nailed with not less than
one nail per tile. As an alternate, the first three courses shall be applied in
mortar over a singl6 layer of Minimum 12 ga. wire mesh with square openings
of not less than 3/8" which is mechanically attached to the deck with not less
than one roofing nail per every 2 ft . For pitches from 6 ":12 to 7 ":12, every
third tile of every fifth course, beginning with the eight course, shall be nailed.
On slopes>7 ":12" all provisions of'System 1' of the Dade County Model
Horizontal Batten Nail -on Tile Specifications shall apply.
Product Control No.: 94- 0309.04
Limitations:
1. This system assembly may be applied to roof slopes of 2 ":12" and greater.
2. Vertical and horizontal battens shall be used on all tile applications on slopes of 2 ":12" to 4 ":12 ".
3. Horizontal battens shall be used on all tile applications on slopes of >7 " :12 ".
4. Nails for attachment of tile shall have heads larger than the pre - formed nail holes in the tile.
5. All nails shall be corrosion resistant. Exposed nails shall be hot dipped galvanized, stainless steel, or copper
only.
6. Allowable height above ground shall not exceed a maximum height of 45' for non -coastal, 30' in Coastal Area
1 and 2, and only by job approval from the Chief Product Control Compliance Officer in Coastal Area 3.
7. Any amendments to these provisions shall be in compliance with Sections 203 and 204 of the South Florida
Building Code.
8. All tiles shall bear the imprint of the manufacturer's name or logo, as noted attached, to permit identification
in the field.
9. The manufacturer shall retain the services of an independent testing laboratory to maintain quality control.
Testing shall be performed on a minimum of five (5) tiles every three (3) months, for strength according to Section
3404 of the South Florida Building Code, and for moisture absorption according to PA 112. Test samples shall be
selected by a laboratory according to ASTM D 3665. Results shall be forwarded to Dade County Product Control
Section. Test reports shall bear a description of the tile by material and color, i.e. cement, grey.
10. All domestic distributors of foreign manufactured tile shall have a completed distribution agreement filed with
the Metro Dade County Office of Code Compliance confirming the distributor's agreement to adhere to the
conditions of this report.
11. Pioneer Concrete Tile shall be installed in strict compliance with the application instructions noted herein as
well as the manufacturer's and Metro -Dade County specifications and application instructions. The Metro Dade
County Model Tile Specification shall take precedence.
12. The use of all pre- formed and specialty tile tested is required as it forms an intricate part of these Product
Control Approval tests.
13. Applications for roofing permits must be accompanied by Section II of the Uniform Building Permit, clearly
indicating the extent of the-work to be performed, along with current manufacturer's specifications and details. In
hu
. addition, a copy of t approval shall be attached to the permit application. Reference shall be made to all
appropriate data for the required fire rating.
-= 000015
r�p)iu'vcu.
Expires:
14. The following documents were submitted with the application:
Product literature on the following profiles:
Hacienda
Rustic Shake
Spanish 'S'
Shake
Slate
9" Flat
2 Peice Barrel
Spanish 'S'
Product profile drawings
Application Instructions
it Diamond P.E.
Metropolitan Dade County
Office of Code Compliance
• )�
•
BUILDING CODE COMPLIANCE DEPARTMENT •
-
-SUITE 1603
'METRO -DADE FLAGLER BUILDING
• • 140 WEST FLAGLER STREET
MIAMI, FLORIDA 33130 -1563
. ' (305) 375 -2901
_ FAX (305) 375 -2908
1. Extension of Acceptance may be considered after a new application has been filed and the supporting data,
test reports no older than ten (10) years, have been re -evaluated.
All reports of re- testing shall bear the seal, signature and date of an engineer registered in the State of
Florida.
2. Any revision or change in the materials, use, or manufacture of the product or process shall automatically
be cause for termination, unless prior approval is granted for revisions or change.
3. Any unsatisfactory performance of this product or process or a change in Code provisions shall be grounds
for re-evaluation.
4. This acceptance shall not be used as an endorsement of any product for sales or advertising puiposes. •
5. The Notice of Acceptance number preceded by the words Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
6. Product approval drawings, where required for.permit applications, shall be provided to the applicant by
the manufacturer or his distributors; unless otherwise noted in the Notice of Acceptance. The prints need -not
be re- sealed by an engineer.
- 7. An annual certificate confirming listing with Factory Mutual Research and Underwriters Laboratories or •
such other listing agency approved by the Office of Code Compliance shall be submitted on or around the first
of April annually.
8. Failure to comply with Standard Conditions shall be cause for termination of Approval.
NOTICE OF ACCEPTANCE: STANDARD CONDITIONS
- 000017 - - -.
Diamond, ES.
roduct Control Division
Supervisor
. r
FIELD TILES
Hacienda
_ TRIM TILES
Hacienda
G00018
UNIVERSAL RAKE
Shake or Slate
Hacienda, Shake, Slate Trim
- HIP & RIDGE
Technical Data
=4-
_ SPANISH "S"
- ono-19-
t
2 -1/2"
•
•
SPANISH f'$" CUT
Techniea9 Data
G0 ..
•
- BARREL. - --
•
- - GOOc211 -
Technical_ Data
•
1/2" TYP
0
y
re)
r4
95' .
Rustic Shake 1 Sl:ate
000022
75"
TechnIcal Data
Technical Data
• 14-3.5"
\ •
Rake Trim
_ Rustic Shake and Slate Tile
- L- -7_000023:
Date 1c Job Address 4 /45 9Y S- • Tax Folio
Legal Description L.07 /g;'/9 (3/ot5,Z S c ;v;_ o /l'1,`Qri �'I oreS �eC /'on 2—
Master Permit # 56,;d1
Owner's Address yY3 /V• E Phone 758- 8q
Contracting Co. /Jh, ', im7 , Address 71/0 de 3
Qualifier A'o Ae F ji rrd15P SSIt - - Phone (305- 947 — 73S
State It Municipal It Competency It C(C/9S > Ins .Co . F6 SA
Architect /Engineer Address
Bonding Company Address
Mortgagor Address
Owner / Lessee / Tenant 3 n Ar
Permit Type(circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING' PAVING FENCE SIGN
WORK DESCRIPTION I4 rnoC c,7 '7 . L/•`rll 111.1 ! ss/o- ai&of Throe It/Aix
" `at ( ar-(6r Se-6
Square Pt. ��•
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO
SO MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR
NOTICE OF COMMENCEMENT).
Application is hereby made to obtain a permit to do work and installation as indicated above, and
on the attached addendum (if applicable). I certify that all work will be performed to meet the
standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S
be done
authori
Sign
Dat
N. ar as to Owner and /or Condo President
My Comnisg, mp Expi§ N A. nSCHER
a y " _. MY COMMISSION H CC3614 EXPIRES
� *. ,r�� :f April 3, 1998
** * -,. , ,,,,, *DNDED TNRU TIDY FAIN INSURANEE, INC.
APPROVED:
' ure of offer and /or Condo President
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Estimated Cost(value) I1 &2:
Mechanical Plumbing Engineering
AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will
in c• pliance with all applicable laws regulating construction and zpning. Furthermore, I
e abov =myl contractor to do the work stated '
x
Signature of Contr
Date:
tor or Owner- Builder
Nbta y as to Contractor or Owner- Builder
My C
", "' ion 93gpt� MAsFCSCHER
':4 MY COMMISSION H CC361486 EXPIRES
f April 3, 1998
BONDED THRU TROY FAIN INSURANCE, INC.
* * * * * **
FEES: PERMIT - 50 4 20 RADON C.C.F. * NOTARY TOTAL DUE 3
Fire Other
Zoning Building Electrical
PERMIT NO. TAX FOLIO NO.
STATE OF FLORIDA:
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. II
1. Legal / description of property and street address: .cif .` / f /9 lj / c k.' S;2 �µ hc��v.s ;nn: M � A'11 ' , S' ore
Arit7(es yy, N• L 9 y''' ��ra07 Shres
2. Description of improvement: Ale -( o f' „,9 W,' a 5 '' —Eh
3. Owner(s) name and address: -o h n /J i�c
Interest in property:
Name and address of fee simple titleholder:
4. Contractor's name and address: IA , IQ, 'a ..,T,-,c,
28/. S/,er a� $ / � f Jvo �L ,3 e . 43�,ot~
a to Coon o f taa
5. Surety:(Payment bond required by owner from contractor, if any) S p p Ft,.O ' t a 0" c ` day 44
Name and address: ~ A u se �a4t� office on , L
1444 tar cat s
�1,,,nelI, `�tcio CuN r¢4
Amount of bond $ T ` G _W l S
county . .
6. Lender's name and address: vu ><NE` my tv R r
Np :c
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be sere
by Section 713.13(1)(a)7., Florida Statutes,
Name and address:
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided
tion 713.13(1)(b), Florida Statutes
Name and address:
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different d -te is spgcified)
Notary Public
My Commission Expires:
NOTICE OF COMMENCE PENT
�nn
.1 MY COMMISSION # CC361486 EXPIRES
Apra 3, 1998
pJ l• BONDED TNRU TROY FAIN INSURANCE. INC.
�•t r
S gnatur o' Owner
Swo n to and subscribed before me this ?J7rday of iffit , 1991
94R2 99 a 1594 MAY 31 13:42
Cun, Pre' Pcvrrj by
J(/ /n 0 c>f / V " ti'C ..10
in Sec-