440 NE 94 St (14)State #
RC0058627
PERMIT APPLICATION FOR MIAMI SHORES VILLAGE
Date 11-10-99 Job Address 440 N. E. 94 Street Tax Folio
Legal Description Historically Designated: Yes
Owner/Lessee / Tenant Gary & Mary Goodenow Master Permit # b
Owner'sAddress 440 N.E. 94 Street Miami Shores Phone 757 -5235
ContractingCo.Quality Roofing Contractor, Tnc_ Address 13800 N.W. 1st Avenue
Qualifier Carlos Arocho Phone 751 -0382
Municipal #
Architect/Engineer Address
Bonding Company Address
Mortgagor Address
Permit Type (circle one): BUILDING ELECTRICAL PLUMBING MECHANICAL ROOFING PAVING FENCE SIGN
WORK DESCRIPTION
Tear off old flat roof, tin cap base sheet felt as per code,
install galvanized eave drip and flashing metals where required, mop on with
type III asphalt one 1ayPr of u Bitume
Square Ft. 1 5 s q . Flat roof Estimated Cost (value) $ 3,700.00
WARNING TO OWNER: YOU MUST RECORD A NOTICE OF COMMENCEMENT AND YOUR FAILURE TO DO SO MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY (IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.)
Application is hereby made to obtain a permit to do work and installation as indicated above, and on the attached addendum (if applicable). I
certify that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that separate
permits are required for ELECTRICAL, PLUMBING, SIGNS, POOLS, ROOFING and MECHANICAL WORK.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable
laws regulating construction and zoning. Furthermore, I authorize the above -named contractor to do the work stated.
Xibt 1/ /7 / ignna of owner and/or Condo President at
"//7/99
Notary as to 0
My Commissio
FEES: PERMIT
MARYLOU HERNANDEZ
MY COMMISSION # CC 880474
EXPIRES: October 10, 2001
"'•� ....... Bonded Thru Notary Pubic Underwriters
RADON
APPROVED:
Zoning Building
Mechanical Plumbing
C.C.F.
Competency # 17889 Ins. Co.
Signature of Contractor or Owner- Builder
, 1144"
Notary as to Contra or Owner - Builder
-
My Commission Expires: ( - MARYLOU H ERNANDEZ
!s'f r:CoMMISSiON # CC 880474
Electrical
No
TOTAL DUE
October 10, 2001
�:..:
airu Natary Pubic Underwi tere
NOTARY BOND
Engineering
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
99R622397 1999 DEC 09 09:26
PERMIT NO. TAX FOLIO NO.
STATE OF FLORIDA:
COUNTY OF DADE:
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with
Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement.
1. Legal description of property and streel address: 440 N . E . 94 Street
Miami Shores, Florida 33138
2. Description of improvement: Reroof to a new Flat Ruberoid Roof .
3. Owner(s) name and address: Mary Goodenow
Interest in property: Owner
Name and address of fee simple titleholder: N /A
4. Contractor's name and address:
6. Lender's name and address:
440 N.E. 94 Street Miami Shores, Florida 33138
Quality Roofing Contractor, Inc.
13800 N.W. 1st Avenue Miami, Florida 33168
5. Surety:(Payment bond required by owner from contractor, if any) DATE OF FLORIDA, COUNTY 0.' DADE
HEREBY CERTIFY tho' this is a try copy , .f the
Name and address: N A originarfi .d in
Amount of bond $ 0 0 0
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided
by Section 713.13(1)(a)7., Florida Statutes,
Name and address: N/A
8. In addition to himself, Owner designates the following person(s) to receive a copy of the Lienor's Notice as provided in
Section 713.13(1)(b), Florida Statutes.
Name and address: N/A
9. Expiration date of this Notice of Commencement: (the expiration date is 1 year from the date of recording unless a
different date is specified)
Signature of • net
Print Owners Name ffkr'/
Sworn to and subscribed before me this f Q day of ,LIG)✓ . , 19 5 i .
Notary Public
Print Notary's Name
My Commission Expires:
RYLOU HERNANDEZ
R • MV COMMISSION r cc 880474
% '' EXPIRES: October 10, 2001
.�.
r . n _a.,w TA. ki 1.. P,hlir IlnMneeitPrc
Prepared by: Carlos Arocho
Quality Roofing Contractor, Inc
Address: N.W. 1st Avenue
Miami, Florida 33168
17' RI.t, 1/nn°
Contractor's Name: � �-� eal'inG ( ,fob Address:
2 Slope Application)
❑ (Asphalt/Fiberglass Shingles)
Flat Roof Area (ft') /,a 9 . Sloped Roof Area (ft')' C) Total (ft') /5 s' , Master Permit No.
Exposure category (per ASCE 7 -88): C Building Classification category (per ASCE 7 -88 table 1):
129.0148 946
❑ New Roof
•
•
•
et r;405
. . Appendix "E"
,UNIFORM ROOFING PERMIT APPLICATION
. PROCESS No.
4 ROOF TYPE
L`7 Re- roofing ❑ Recovering
ROOF HEIGHT AND SYSTEM DETAILS
• • • (Draw details as needed)
1 k x a,h
..ie !n -s[1 2� r, �
1,1
A
DETAIL 1 & 2
ROOF CATEGORY
❑ (Nail -On Tile)
❑ (Metal Roofs\Wood Shingles & Shakes)
Ft.
Ft.
A
V
v
ATTACHMENT
Fastener Type: r h5 �, r'ce. is
•
SPACING
, Perimeter: to D c.. Corner : Io
Page -1
❑ Repair ❑ Maintenance
r
r
r
IlLio
r
r
•
❑ (Mortar- Adhesive Set Tile)..
❑ (Other)
ROOF PLAN
I
�
I
ATTACHMENTS REQUIRED
1) Fire Directory Listing Page
2) Dade County Product Control
Notice of Acceptance -Cover Sheet
a) Specific System Description
e) Specific System Limitation
c eneral Limitations • •••
d) A .licable Detail Drawings
3) Municip. Permit Application
•4) Other Com•.nent Approvals
Rid Ventilation?
M tQ HPICHT
Deck type:
v IJ:tderleyment
Ituulatlon:
I ts�
710 Or 1LO>Z
D ETA I L . 3
(Pnlax.1: x �l (A.rod
,
(Pnlax2: k (Aerodynamic Multiplier
(Psnax3: x ? (Aerodynstmlo ' ulUplier):
,Append.ix "
U ORI1x RQOP' NG PERIYIJT APPLICATION
' PROCESS No.
I5 L OPED SYSTEM DESCRIPTION
Fastener type & spacings
Cop Sheets
Root . Cover!
A.. Drip edge:
Page -2
ONS
PCA:
PCA:
PCA:
As it pertains to this Appendix "F ", it is the responsibility of the roofing contractor to provide the owner with the
required roofing permit, to provide the owner with this appendix and to explain to the owner the content of this
form. The provisions of Chapter 34 of the South Florida Building Code (SFBC) govern all the minimum
requirements and standards of the industry for roofing system installations. Additionally, the following items
should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the
adjacent box indicates that the item has been explained.
1. Aesthetics - Workmanship: The workmanship provisions of Chapter 34 are for the purpose of
providing that the roofing system meets the wind resistance and water intrusion performance standards.
Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architecttira! appearance, that are not part of a zoning code, should be addressed as part of the
agreement between the owner and the contractor.
2. Renailing Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed
in a ccordance with the current provisions of Chapter 29 of the SFBC. (Tate roof deck is usually concealed prior to
removing the existing roof system)
V r/'
j 13. Common Roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and /or
owner should notify the occupants of adjacent units of roofing work to be performed.
4 _,(114. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail
penetrations of the underside of the decking may not be acceptable. The SFBC provides the option of maintaining
this appearance.
APPENDIX "F"
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
S. Ponding Water: The current roof system and /or deck of the building may not drain well and may
ca se water to pond (accumulate) in low -lying areas of the roof. Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
roofing system is removed. Ponding conditions should be corrected.
6. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
ov rloaded from a build up of water. Perimeter /edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with Chapter 23 of the SFBC.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior
of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It
may be beneficial to consider additional venting which can result in extending the service life of the roof.
S. The owner may contact the tvliami -Dade County Consumer Ser i.:es Department for further
information regarding the above.
? s /Agent's Signn ire Datc
Contractor's Signature
•
ETRO
•
Approved: 06/19/97
PRODUCT CONTROL NOTICE OF ACCEPTANC
GS Roofing Products Company, Inc. •
5523 MacAuthur Boulevard, Suite 900
Irving, Texas 75038 •. • •
Acceptance No.: ,.97-0520.01 .. RevISes 95- 0502.04
•
Expires: • 06/19/00
4 ....
Internet mail address: postmaster @birlldingcodeonline.eom
w
Z:aT
• a �t ?'
METROPOLITAN DADE CO ' : • ••
4 •;:.
METRO -DADE FEAGLER161j ,LLDING ' :'
BUILDING CODE COMPL ANCE., .I IC
OF�E. , •
METRO.OADE•FLAGI ER'BUILDING•,: h•
140 WEST FLAGLER STREET, SUITE 1603• • :•
MIAMI. FLORIDA 33130•4563 .
• (305) 375.2901
FAX ,(305) 375.2908 • •
PRODUCT CONTROL DIVISIOt�ja; _' ..
(305) 375.2902:`.:•: ,
FAX (305) 372.6339 '`:;..:' •
E•
Your application for Product Approval on
GS Roofing Products Modified Bitumen RoofSysterru Over Wood Decks
under Chapter 8 of the Metropolitan' Dade County Code governing the use of Alternate Materials and Types 'of
Construction, and completely described In the plans, specifications and calculations as submitted by:
Factory Mutual Research Corporation anil Underwriters Laboratories, Inc.
has been recommended for acceptance by the Building Code Compliance Department to be used in Dade' Counry,
Florida under the specific conditions set forth on -pages 2 through 31. and the standard conditions set forth on page
33.
The approval shall not be •valid t.fter the expiration date stated below, The Building Code Compliance;Office
reserves the right to secure this product or material•at•any time for a jobsite or manufacturer's plant fo {;
control testing. If this product or material fails perform In the approved manner, the Building Code Compliance
Office may revoke,, modify .or suspend .the us; of such product or material immediately. The ; applicant shall
re- evaluate this product or material should any amendments to the South Florida Building be enacted affecting
this product or material. The Building Code Compliance Office reserves the right to revok; this approval, •if It is
determined by the Building Code Compliance Office that this .product or material fails to ; meet the requirements of .
the South Florida Building Code. The expense ofsuch testing will be incurred by th man ac r. „ , ; ,. , ;. •
Raul Rodr• ucz '
Product Control Supervisor
•
THIS ISTHE COVERSHEET. SEE ADDITIONAL PAGES FOR SPECIFIC AND GENERAL
CONDITIONS
. BUILDING CODE COMMITTEE
This application for Product Approval has been reviewed by the Metropolitan Dade County Building Code
Compliance Department and approved by the Building Code Committee to be used in D County Florida' under
the conditions set forth above.
es *anger. P.E.
Director
Building Codc Compliance Dept.
Metropolitan Dade County
Homepage: http : / /www.bulidingcodaonllne.com
Applicant:
• .
CS Roofing Products Company, Inc. (MB)
5525 MacArthur :Blvd.
Suite 900
Irving, TX 75033.••
Catezorv:
Sul
Tvoe:
• •
• ..
• . • • .• •
'
•
Membrane.Roofing System
Built-up Roofing
Madified Bitumen
SBS/APP
...•
• • .• ' • '•IvstdiniDescrii3tion
Contact:
Pat Neuhaus
Commercial Dis.triat
2900 Bird SL
• ,:Charieston Height,s; S.04 . 29405 .
. (803).744-7451
• •
2
•• . •:*
*a . AI •
•• .•
• .• • .: • • • • • tei t;•. t •ac
• • •; • ••
SYSTEM APz'Qv,
••• • • •: • .
•
•
•
uloaga-Plans Examin
Product Control 97-0520.01
Product Control No.: 97-0520.01
• APprovalpate:. June 19 1997
„... •
Expiration Date: June 19. 2000
GS Roofing Products Company,.Inc. manufactures and markets nationally a complete line of residential and
commercial BUR 'modified bittimert irroduCts Company, Inc. 'markets thelerfaucts
through local distributioidn'the South' FlOrldtiliiiisdieltore:. •• • •
. .
GS Roofing products atial'iystems are the'restile:of years:Of ifialiufacturing'experience and pioduct developtnent and
have been proven by.year expedincolii ctiiid fie ' •
-.* •4. •••• • • - ?..t: •
GS offers a variety .0 r a pprovediniulatechiiiiIii6iitIdiuliteirtoOfing systems. For detailed system• constructions,
refer to the following publications: "Corhnierctil.ROOf SYSteiiiSpecifiCatiori Manual". • • •
GS products and systems,haye been tested•tricomPliance with all'pro ions of the South Florida Building•Code as
%yell as Underwriters. Latioiatories; inc.';:qtrid Mutual Research Corporation for fire and wind uplift
resistance. • •• .. .• ",
• •
GS provides .technical service and warranty Information through regional offices. For the Siwth Florida
• Metro-Dade area, call 1-800-777-2563.
• •V
uct Control Div.
Polylsocyanurate ComposIte'8oard•. + :•'" •�• ..
•
r "•
Maximum Design Pressures
..Material Design Pressure
Wood -4S.0 pst
Maximum Fire Classification
Material Classification
Wood Class A
ran uloaga -Plans Exam
Product Control No.:• 4- 0520.01
. •
�•.r
; insulation Types
Fibrous glass • .... • . -f'; ;;•J1,.; •,; ..:t::3v�;,: •
Perlite ,
Fiberboard , '•.'r . •
Rockwool
Po lyiso.cyanurate ..: ,•,r �I K�,::..,,;.:::,. .
. •
Note: Fire classlfcatlons and maximum design pressures do not reference all assemblies over deck types.
Review system•listings for design pressures and•the Uaderwriters Laboratories Rooting Materials Dlrectory •
orother approved testing agency listing directory for Fire ClassIfcations.
..'r
L
r
•
Wood Deck System Limitations:
col
A red rosin sheet shall'ba Installed on all wood plank decks to eliminate asphalt seepage and bonding of
base sheet to wood plank•deck. Red rosin sheet may also be•installed on plywood decks as,an option.
2 Pre - assembled 'Cap Nail' shall not be used for base sheet attachment.
3 When All Weather Empire base sheet Is installed as the base sheet, a ply sheet of ASTM D'4601 type 11
(type 02) must be applied in approved mopping asphalt applied within:the EVT range and at•a rate of
0-40 lbsJsq prior to installation of membrane.'
•
• :., .i.•,. • . •
•
•
uloaga -Plans Exam'
•
Product Control No.: 97- 0530.01 •
uct Control Div.
GENERAL L,IatITATIONS
Product Control No.: 97- 0520.01
1 All asphalt shall comply with ASTM D 312, type 111 or IV requirements and approved by applicant
'- Fire ratings are determined by a combination of slope, deck type and assembly. Refer to the current
Underwriters Laboratories Roofing Materials Directory or other fire testing data listed in thc testing file
Fire ratings shall be in strict compliance with Sections 3401.5 and 3401.6 ache South Florida Building
Code.
3 Maximum slope range varies for each system. Consult the current Underwriters Laboratories Roofing
Materials Directory and manufacturer's specifications for compliance with design criteria for each
project.
An overlay and/or recovery board is required on all applications over closed cell foam insulations when
the base sheet is fully mopped in hot asphalt.
5 All work shall be performed by a contractor licensed to do roofing work in Metro -Dade County.
Contractor shall be familiar with the details and specifications published by the manufacturer and the
requirements of the South Florida Building Code.
6 The submission of system specifications and details shall accompany the Section 11 Building
Permit. This information is available in the publications listed in the 'System Description' of t his
Product Control Approval. The submission of these documents, as well as the proper application and
7 installation of all materials shall be the sole responsibility of the contractor.
Perimeter and corner areas shall comply with thc elevated desi�
calculated in compliance with Cha ter 2 ,n pressures of chest roof areas, as
p 3 of the South Florida Building Code. Anchor or base sheet
fastening patterns and/or insulation attachment densities shall be increased in compliance with the
provisions set forth in Metro -Dade County Roofing Application Standard PA 117 to meet these elevated
design pressures.
8 All attachment and sizing ofperimeter nailers, metal profile and/or flashing termination designs shall
conform to Metro - Dade County Roofing Application Standard PA 1 1 1 and the wind load requirements
of Chapter 23 of the South Florida Building Code.
9 Flashings shall be installed according to the manufacturer's standard details and may be applied in cold
application adhesive, approved asphalt or may be applied in conjunction with an approved torch applied
modified bitumen membrane. Specific details, approved by the manufacturer, shall be submitted with
the Section 11 Permit Application. All details shall comply with the provisions of the South Florida
Building Code.
10 Fastener spacing for anchor or be sheet attachment is based on a Minimum Characteristic Resistance
Force (F') as determined through field testing in compliance with Metro - Dade County Protocol PA 105
or PA l05(A). If F', as tested, is less than that listed in the System Limitations, a professional engineer
may 'submit revised fastener spacings utilizing F', taken from a Metro - Dade County Protocol PA 105 or
PA 105(A) test report, and the provisions set forth in Metrd =Dade County Roofing Application Standard
PA 117.
1 1 Fastener density for insulation attachment is based on a Minimum Characteristic Resistance Force (F')
as determined through field testing in compliance with Metro -Dade County Protocol PA 105. If as
I'-
tested, is less than 275 lbf., insulation attachment shall not be acceptable.
Asphalt moppings shall be applied with approved asphalt and shall be in compliance with the
equiviscous temperature (EVT) methods of asphalt determination. Asphalt containers or bulk tickets
shall indicate an EVT, finished blowing temperature (FBT) and flash point. Asphalt types and
temperature ranges shall be in compliance with Subsection 3403.4(A)(3) of the South Florida Building
Code.
13 Insulation may be applied in multiple layers. The first layer shall be attached in compliance with the
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of aproved
asphalt applied .within the EVT range and at a rate of 20 -40 lbs. /sq., or mechanically attached using the
fastening pattern of the top layer. Refer to manufacturer's literature and/or the NRCA Roofing and
Waterproofing Manual for correct application procedures of insulation panels in approved asphalt or
adhesive, which shall comply with the provisions of M
PA 117. nr ; ; ;.• • • .. A ppfic.acion Standard
30
oaga -Plans
uct Control Div.
14 All standard insulation panels sizes are acceptable for mechanical attachment. When a li
approved asphalt, panel size shall be 4' x 4' maximum. pp cd in
1'5 In re -cove
rY applications, prior to.the application, all existing roof surfaces used as a bonding substrate
shall be tested in compliance with Metro-Dade County Protocol 4 for: uplift resistance :- Test
pressures shall be calculated In compliance with the wind load requirements of Cha ter 23
Florida Building Code for the roof in question, p of the South
16 In re-roofing applications, pplications,moisture content in an existing roof must be in compliance with Subsection
3 (n) of the South Florida Building Code.
17 Roof goods shall be stored on end and on a clean, flat and dry surface.
13 Ifce sired an
q y Factory'Mutual Approved vapor barrier in conjunction with proprietary or a
adhesives may be used prior to the application of the insulation layer.
19 Consult current Underwriters Laboratories Directory for the appropriate coating fo approved
assembly to obtain the required fire eating, � r each roofing
Subsection 3401.5 and 3401.6 of the South Florida Building Code for strict
tiire c as si fi ca t with
ficatton.
Product Control No.: 97.0520.01
uloaga -Plans xa - -•uct Control Div.
CS Roofing Products Company, Inc.
5525 MacArthur•Blvd., Suite 900
Irving, Texas 75038
ACCEPTANCE NO.: 97-0520.01
APPROVED: June 19. 1997
EXPIRES: June 19, 2000
NOTICE OF ACCEPTANCE STANDARD CONDITIONS
Renewal of this Acceptance (approval) shall be considered after a renewal application has been filed and the
original submitted documentation, including test supporting data, engineering documents, are no older than
eight (8) years.
Any and all approved products shall be permanently labeled with the manufacturer's name, city, state, and
the following statement: "Metro -Dade County Product Control Approved ", or as specifically stated in the
specific conditions of this Acceptance.
3 Renewals of Acceptance will not be considered if:
a) There has been a change in the South Florida Building Code affecting the evaluation of this product and
the,product is not in compliance with the code changes;
b) The product is no longer the same product (identical) as the one originally approved;
c) If the Acceptance holder has not.complied with all the requirements of this acceptance, including the
correct installation of the product;
d) The engineer who originally prepared, signed and sealed the required documentation initially submitted,
is no longer practicing the engineering profession.
4 Any revision or change•in the materials, use, and/or manufacture of the product or process shall
automatically be cause for termination of this Acceptance, unless prior written approval has been requested
(through.the•filing ofa revision application with appropriate fee) and granted by this office.
5 Any of the following shall also be grounds for removal of this Acceptance:
a) Unsatisfactory performance of this product or process;
b) Misuse of this Acceptance as an endorsement of any product, for sales, advertising or any other
purposes.
6 The Notice of Acceptance number preceded by the words Mcu•u -DaJc County, Florida, atd followed by the
expiration date may be displayed in advertising literature. If any portion of the Notice of Acceptance is
displayed, then it shall be done in its entirety.
7 A copy of this Acceptance as well as approved drawings and other documents, where it applies, shall be
provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site
at all times. The copies need not be resealed by the engineer.
8 Failure to comply with any section of this Acceptance shall be cause for termination and removal of
Acceptance.
9 This Acceptance contains pages I through • 32.
END OF THIS ACCE
32
Product Control No.: 97- 0520.01
roduct Control Div.
Membrane:
Surfacing:
Maximum Design
Pressure: -45 psf
Maximum Fire
Classification: Class 'A'; see General Limitation #2.
Maximum Slope: 1 :12; sec General Limitation #3.
Specification No.: GMS 2 -3, FRP 2 -3, GTS 2 -3, FRBC 2 -3
.4
27
Product Control No.: 9 0520.01
Membrane Type: SBS MODIFIED
Deck Type I: Wood. Non - Insulated
Deck Description: "'/,_" or greater plywood or wood plank decks
System Type E: Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One jilt' of GS*GIas:Base,'GS Flex - Glas Base. Flex -I Glas FR Base or GS Poly SMS base
Mechanically fastened detailed below.
Fastening: Base sheet shall be lapped 4" and fastened with approved roofing nails and in caps 9" o.c.
in the lap and two rows staggered in the center of the sheet 12" o.c.
Ply Sheet: (Optional) One ply of GS Glas Base, GS Flex- I -Glas Base, Flex- l -Glas FR Base, GS
Po!ySMS or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply
Sheet (Type VI) adhered to the base sheet In a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 Ibsfsq..
One ply of Flintlastic CMS, Flintlastic Premium GMS, Flintlastic FR -P, Flintlastic
Premium FR -P, Flintlastic FR -PG or Flintlastic FR Cap adhered to base or ply sheet with
approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs. /sq. or
Flintlastic GTS torch adhered to base or ply sheet
(Optional) install one of the following:
1. 400 lb.sq. gravel or 300 lbfsq. slag in a flood coat of approved mopping asphalt at an
application rate of 60 lbJsq..
2. Karnak 97 or APOC 212 Fibratcd Aluminum at an application rate of 1 '/ gal /sq..
Frank Zuloaga -Plans Examin Pro uct Control Div.
�jy
ROOFING SYSTEMS (TGFU)— Continued
Ana: Una Payer 'Fl lnci do GTA (•3/4 sq or •3 so), GCS' (modified
'n). here !used' or 'Fllntlastie GAS'. bot mopped.
ink: ^GC 'No. i12 Fibratid'Alunrtnum', et 14/2 gal. 100 sq/ft.
lnclhiei 3/4
Retarder (optional); Type G2 'Glasbasc' bur .ih.et or UL
,,c vapor retarder.
:ion ((0pCional); one or more layers or combination of the
^g: Ul :regard Premier, polylsocranurate. pertite. glass fiber or
-ii=tr insulation.
•nacr Ono layer of Type G2'Glastase' bast sheet.
rank: One layer rat - FontLtstic STA (modified bitumen), heat fused.
Karnak 'No. 97 Fibrotic; kluminuns', at 1 -3/2 gat per 100
15/32 lndlne: l/2
Lion (Optional): Schuller International 'UltraGard Premier',
cyan :race. wood fiberboard, polite, fiberglass. lsoeyanunte, any
' - Sr.
h:et One or nsorc plies of'Glasbase, hot mopped ormech■tnicully
rang: One p(y of'Flintllstic FR' (modified bitumen), hot mopped in
en: Potyisocyanurate. glass fiber, polite, wood fiber, hot mopped
nznically fastened, any thickness.
.he et: Type G2, mechanically fastened or hot mopped.
rant: "F GTA or STA ", heat fused.
Ing: henry Co. "Henry 520 Aluminum', applied at 1 -1/2 gal/sq.
Iodine: 1/4
on' (optional) :•Glass. Ober, ptrlite or wood fiber board.
eat Type G2. nrtehanically'fastened. •.
rani: aintWstic STA', 1 TA', `GTA Clack Diamond' or 'CIA 1Vhite
ne', heat fused.
t„g Karnak Chemical Corp, 'Karnak No. 97', 1 gal/sq•
Incliner 1
eon: Pot glass Aber. pertite, wood fiber, tnechanic.ally
cc er adhered with hot roofing asphalt any thickness.
;1-,eat ' Type G2, mechanically thickness. stened or adhered with hot roofing
tang: 'FUnt4satic GMS', 'CMS Premium', adhered with hot roofing
;rag: Kaunk Chemical Cory, "Karnak No. 97 flbratcd Aluminum
a Roof Costing'. 2-1/2 gal /sq. •
15/3?' Incline: 1
;ins blocked with 2x4'5.
;:iPn: Glass fiber, perUte, 3/4 in, min. joints to insulation must bas
Sheet Typz mechanleclly fastened or adhered with hot roofing
one: "Flintl.stic GMS', adhered with hot roofing asphalt
ins: Karnak Chemical Corp. 'Karnak No. 97 Fibrated Aluminum
Roof Coating', 2.1/2 gal/sq.
^on:
r 1/2
Polyisocyanurate, glass fiber,partite wood fiber, mechanically
.ed or adhered with hot roofing asphalt, any thickness.
Shat= Type G2, mechanically fastened or adhered with hot roofing
, rare: " %unt!airic STA'. 'GTA', 'GTA Black Diamond" or 'GTA White
:r.' neat fused in place.
- ingr Karnak Chemical Corp. 'Karnak tlo. 97 Fibrated AlUmtnuni
Roof Coating', 3 gat/sq.
Indioes 1
(p
ti Up tion;1)1'L) 1ti99lus.6her, olyurethmnt, Loryanuratl,
j
Tic combination socyanurekt /perUte, p7R rethane /pe rwood
any thickness, hot mopped or nailed.
• n n e: 'Flinclastic STA', 'GTA', 'GC& Blade Diamond', `Flintlastie GTA
Otzcto:td 'GMS', 'GM5 -51.1', "GAS Double Coverage' or 'GMS
heat fused or hot mopped in place-
- ins.: Grundy Industries, Inc_ 'al MB Aluininunt Roof Coating' at 1;2
15/52 L• dirt: 1/4
.don (0pc(onal): Any thickness polyicocranurote, glass fiber or
• m :chonically fastened, joints in insulation 111U 5t ba otfYat 6 in.
_inns in deck.
Sheets T G2 base /ply sheet, mechanically fastened' or hot
:feet: Type G2 bass /ply shat, mechar•.ically fastened or hot
o.
r. rats 'Flintlastic c3,'' 'GTA Yfhit4 Diamond' or "VA Black Diamond'.
.ng: Grundy's at MB Aluminum Roof Coating' at 1 to.2 gal/sq.
:'on (Optional): Polyisuryanurate, glass perlite, mood fiber,
�tbin2tion, any thickness, mechanically fastened. • .
LOOK FOR MARK ON PRODIJCT
ROOFING S''STE0.5 (TGFU)-- Continued
Base Shutt: Type G2, 'Flex•I -G'as FR" or'FlintLlstic FR Oast', mechaniq
fastened or adhered with hot roofing asphalt
M embrane; 'flintlastic FR•P', - Fllntlastic Premium FR•
- Flintlastic- FR/PG or - FUnrtsstic FR Cap' adhered with hot roofi
42- asphalt. '
•Oeckr C.19/32' tndtne: 1/2 -:
'All j oints In deck blocked •rich 2s4's. • . �f
• Insulation 0 tional : P•rl tape anunce lass fiber. .. ! '
(V ) Y Y 9 Vertitc.' ,
combination any thicknes mechanically fastened.
U. Sheet: Typo 64. mechanically fastened or adhered with hy t : "v.
asphalt....... 't: 04 Membrane.: ' Fllntlsstic E R - P', 'illntlastic Premium FR- r.or'fin. 1:!e;
Rip. adhered with hot :oo(nq asphalt ..�3 --1 •1G
J �Q !none: 1/2 It14.
insulation •(0ptiortal): E'S, any thickness, covered with 1/2 • i � 7
• polite or wood fibe:. mei hankAUy fastened. ,,' a
• asphalt- se Seet Type G2, mei hanically fatened or adhered with hot)ooi��
0' +�.5's
Membrane:'Flintlastic Ft•P"; 'FlintllstiC Premium FR -F' or'R) .: tecef
'Fit/PG', adhered with !sot roofing asphalt. a rt ; ;��
14. Deck; NC Inclhsc: 1/2 t :•; S .
. , Insulation:, Polyisocyarruratc, . glass fiber. ptrlite, wood •fibec �•,
combination, any thickc.eis•'mecltanipUyy fastened. •• • ; ,•R ;g
• Base Shoat: Type 62 or 'Rex- 1•gla: , 4dhcrcd •with`hot,rooli • , • '
Ply Sheet - Poly SMS Base Sheet', adhered with •hot roofing :zip '7/ J
Membrane: "OAS' adhered with hot roofing asphalt. •..:• -'j .. s
Surfacing: Karnak Chemical Corp. - Karnak No. 97 Flbrated -,d!.4
r 4
Asphalt Roof Coating ". at 2.1/2 gaVsa. q�; e C�
15. Deck- NC lndica 1/4 1., :•'(:litre
Insulation (Optional :: Polyisocyanurate glass fiber, pertite.'wo.l' fir ;
any combination. any thickness, mechanically fastened or adt ee t '
hot'roofing.aspha19..
Base Sheet Type 62 or• i•glas', mechanically fastened'o a,1 ;r
with hot roofing up talc- .. 4s t. • e o;
Pty Sheet ( Ophonal): Type G2 or'flea •r .•I- glas', mechaniolly L' d
asp ..
a dhanad with hot rosfin9 as b;.r
Membhaltrane: 'Flintla: tic G115p '61.45 Premium', adhered witfi`ho 'j '
.
Surfacing: Asphalt Products O1 Corp. 'APOC -400 Sunbrital;•,3 :ga + ;
16. Da C - 15//32 Trrciine: )/4 : r:;j} ..
e•tii
Insulation: Glass Ibex, pertitc, 1 in. min, joints in ins ry �f
offset 6 tn. f j tints to deck, nsochamally fastened..: C rj ! •2t:fift
Base Sheet: Type G2 or ' Flex t - gtas'..mechanically fastenrid`'o : f►aab
wlth•.hot roofing ; sphalL :r tc �
Ply Sheet ( Optioual): Type 62 or'Rc .I- ally
glas', mechanic. .- �f J•
adhered with hot roofin re.. ' s asphalt . �'
rjklo.
Membrane: 'Flin'lastic GMS' 'GMS Premium', adhered witnih• y�tiGl •
asphalt • r. e! �
Surfacing: Asph :alt Products Oil Corp. 'APOC•400 Su nbrite'.,r^ ' :I,: i r, } ,! y
• Deck NC '�' ` ' incline: 1/2 •' :'v ? y r i Insulation (Optional): Polyisocyanunte perlite' glass fi• i is, ± fiber, any th(ctattis, mechanically fastened or hot rno ped•i S Base Shuet: Oat or more layer. of Type 62 or "F7ez -i-g1i 4' e
!.� '
fastened or hot mopped in place ;v,:y a: P(y Sheet (Optional): One or'more layers or Types G1, G2 t i •
mechanically (atoned or hot mopped in place. • •• •+•• '.6. i .s l� �r1',
Membrane: Fintlestic GTA' 'GTA Blade Diamond', 'GTA N �� ' '
or'STA', heat fused. : +'• 7sf : an'tri4% •
Surfacing: Karnak Chentical Co. * NO. 97', applied at'',3(.:1 . alf. r i.
Insulation (Optional): Perilte, glass fire III - '
mopped in pacit, 2 In. max thicknus. • • : .;.. vol I .'7‘1111`1‘,44,C1.1").P,,t!tdist:
Base Sheet: One or MOM layers of Type GZ - Flax-l-glks'. • 1 . 1 '14:4/F 4 4041
Membrane: 'VA', 'MA Black Diamond', 'GTA'WhirrDiam • . g
heat fused .
19. Dec C-15/12 • • • • • ;..11?•1"
Surfacing: APOC No. 212 Aluminum Coating,.applied'ac- l',!4\0241;
FR/PG', sot mopped in place., • ; .� r '" 'o
20. Dock NC r. - iodine 2 .'• .. • ; . • • J 1.3 1i :
• Insulation (optional): Pertite, glass fiber. polyurathgn
phenoUi, combination isocyanurtte /pertite. polyureth
fiber, a sy.thickness, mechanically Fartonad or hot m
• Base Sheet "Flex•I -Gras FR Bas e , Type G2 or'Fterl•I -GC
fastenrd or hot mopped in place •''
•
•
r
nom,'
FP•.P'
t. Pecs•. C•
lnsulo
or hot
Base
Hemp
Pact C•
Insul
comb'•
muff
Base
soots,
ease
•ith
Ply
nets
Orcr,
Inst
tam
B..s
rots
• : Fl
• fh
, dr
9'
Co
r•,
r>,c
c.
h
Owner's Name and Address
Regirtered Architect and/or Engineer . ... —...._..—.
Name and address of licensed. cirmtroctor
Locato and legal descr iption of lot to be buill
Lot N/' 7 Block N.5 / Subdivision
Street and Number where work is to be done ij4z42._ 4 /
State work t'o be do pc and purpose of building ,( floor ).
ll 4
Disapproved ..... Date..
(Signed)
Building Inspector
Chairman
Slen,Licr
Member
Council Approved _
MIAMI SHORES VILLAGE
RILM-DING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
A is heirriv made for the soilproval of the ktailed stattiiiesit in me point and specifications submitt
Inc or ether structure larrein itteecribrd. This application is made to compliance and conformity with the 'Wilding Ordinance of Miami
Shorrs florid& anti all provisions ft( the Laws rif the State of Florida, all ordinances of Miami Shores Vinage and all rules and
regulations of the $,1,1,n g Di awn ol Miami Shores Villme shall be complied with, whether bereia specified or set. A copy sdappenead
plans and specifications roust be kept at building during minus of the work.
Date
New Building Remodeling Addition
•
• To be constructed of kind of foundation
Estimated Total cost of improvements $ Amount of
Zone cubage required Plan Cubage
Distance •to next nearest building .Siza of Building Lot
Maximum live load to bt borne by each floor
1 hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to.
The taniler,icr.eil applicint for this lmildng permit does hereby certify that he understands and accepts his obligation% a% an employer
of .tbur under the Florida NVorkmen's Compensation Act, living Section 5966, Compiled General Laws of Florida. Perinamnt Supplement.
srui has complied %%Olt the proe)%ion% thereof, and will require similar sompliance from all contractors or sub-crintractors employed by hmi
in tl:c stork to be performed tinder this permit; and will post or cau‘e to be posted for inspection on the site of the work such uhlit notice
or notices as arc required by the Ac.t. The undersigned agrees to employ only such subcontractors, co weir to be peri er this
permit. as are licensed by hliami Shores Village.
Rein.uks
g' •
STATE OF FLOT,IDA,
COUNT y OF DADE. j "
Before:re, the undersigned authority, a notary public, duty authorized to administer oaths and take acknowledgments, personally ap-
peared .....
and who, being by me first duly sworn, upon oath deposes and says that he is the
of tl.e above described construction. that he has carefully read the foregoing application, and that he did sign the same, and that all facts
therein by him stated are true.
Permit No.._:?.. Date Read. Sworn to and Subscribed before one.
Notary Public, State of Florida
My Commission Eapires......._
PLANNING BOARD DATE
Member —
Member
Date Disapproved
.4ZA 0 .19 _
No l/ a
30"/ - A/
ejot /4
_&
and for Do ether purpose.
Repairs No. of Stories _
Roof Coverimg ......
Permit
• ............
to me well losOwn.
..... Date
NUT); A Ohne of $1.00 will be made foe mating corrections et changes to this application *her approval has hers nbtained from
ttie I'l.onrott.,: ilu ir cj
A 11. lion lee of $1.00 will be charged when Rich re-kupeetion 1. Nods easeetwary b bosprog---• for tesspintion er fault,
niaterali anii/or workmanship.
Owner's Name and Address
Registered Architect and /err Engineer
Name and address of licensed contractor
Remark
MIAMI SHORES VILLAGE
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby made for the appfbval of the detailed statement of the plans and epetifa:ations herewith submitted for the building or other structure herein.
deem' bed. This application is made in compliance and conformity with the Building Ordinance of Miami Shores Village. Florida, and all provisions of the Laws of the
State of Florida. all ordinances of Miami Shores Village and all rules and regulations of the Building Division of Miami Shores Village shall be complied with. whether
herein specified err not. A copy of approved plans and specifications must be kept at building during progress of the work.
Nas
u 1 1 i A4ie'
,
Location and legal description of lot to be built on:
Lot Block Subdivision c
Street and Number where work is to be done 1 ` 1 0 1 �1 G
St901 worMo be d urwse of building Iby floors). state 99terior co 1 bmit amples)
Ke -t�0 4t � 2r) -f Wi � ju i 11 -
111-1,4 i74004 F/4
and for no other purpose.
New Building Remodeling AddiNrn, Repairs N f Spit; s 61 1
lb be constructed of Kind of foundation Roof Covering 1 `i ' '
Estimated lbtal cost of improvements S _014.31110D Amount of Permit $ 3i " /20
Zone cubage required Plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live low to be borne by each floor
I hereby submit all plans and specifications for said building. All notices with reference to the building and its construction may be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligatons as an employer of Labor under the Florida Workmen's
Compensation Act, being Section 5966, Compiled General Laws of Florida, Permanent Supplement. and has complied with the provisions thereof, and will require similar, •
compliance from all contractors or sub - contractors employed by him in the work to be performed under this permit: and will post or cause to be posted for inspection
on the site of the work such public notice or notices as are required by the Act. The undersigned agrees to employ only such subcontractors. on work to be performed
under this mit, ; are lcena'. Miami Shores Village.
(Sign
1 V 9
suet_ g5
rI'/'
336 1)
STA IF FLORIDA
COUNTY OF DADE.
Before me, the undersigned authority. a notary public. duly authorized to administer oaths and take acknowledgments . personally appeared
and who. being by me first duly sworn, upon oath deposes and says that he is the
of the above described construction. that he has carefully read the foregoing a • ation, and that he did sign the same. and that all facts therein by him stated are true.
Permit No.
Disapproved
(Signed)
L ✓ o „.
•
Date J ■
Date
Read. Sworn to anti Subscribed before me.
Notary Public. State of Florida
to me well known.
Building Inspector • • My Commission Expires
PLANNING BOARD DATE
Chairman Member
Member Member
Member Member
Council Approved Date Disapproved Date
NOTE: A charge of 525.00 will be made for making corrections or changes to this application after approval has been obtained from the Planning Board.
A re- inspection fee of 525.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty materials and or workmanship.
BUILDING INSPECTION DEPARTMENT
APPLICATION FOR BUILDING PERMIT
Application is hereby wade for the approval of the detailed statement of the plans and specifications herewith submitted for the build -
ing or other structure herein described. This application is made in compliance and conformity with the Building Ordinance of Miami
Shores Village, Florida, and all provisions of the Laws of the State of Florida, all ordinances of Miami Shores Village and all rules and
regulations of the Building Division of Miami Shores Village shall be complied with, whether herein specified or not. A copy of approved
plans and specifications must be kept at building during progress of the work.
50 squares
Owner's Name and Address . . . F ' . , . . . . Ka 'o$ t er
Registered Architect and /or Engineer• .... • •.,. „, . ,,.TI.... „..•__1•_•1•_- •.....
Name and address of licensed contractor Lang Ro o f in. & Tile Co„, ? �,� 7.„17, 71 t, _,,,,,
Fla. 33150
Location and legal description of lot to be built on:
Lot Block Subdivision
Street and Number where work is to be done 440 t... .J4t__ct'et'ta ... 51w•ga_.-. State work to be done and purpose of building (by floors )....1w0.!i._.C.Q.1la.._...1J1�
felt... to...,sheathi_ng,
cap 1 -30r/ felt to sheathi na.L_.. op 2 - 15-r felts with hot asphalt for o other v pose
laver of. ?. ®® . T�°�sr�l ipbedded int qt poured alt.
Building �a lS _. _ .._..`. , �temodclmg Ad dition 1 asp Ke v a i rs No. of Stories
To be constructed of Kind of foundation Roof Covering Tile 8: Gravel
Estimated Total cost of improvements $ 8,430.00 Amount of Permit t 11.00
Zone cubage required plan Cubage
Distance to next nearest building Size of Building Lot
Maximum live load to be borne by each floor
I hereby submit all the plans and specifications for said building. All notices with reference to the building and its construction may
be sent to
The undersigned applicant for this building permit does hereby certify that he understands and accepts his obligations as an employer
of labor under the 'Florida Workmen's Compensation Act, being Section 5966, Compiled General Laws of Flo ' Permanent Supplement,
and has complied with the provisions thereof, and will require similar compliance from all contractors or • con actors employed by him
in the work to be performed under this permit; and will post or cause to be posted for inspection on th• site of lie work such ublic notice
or notices as are required by the Act. The undersigned agrees to employ only such subco • actors, • work . • be perform • under this
permit, as are licensed by Miami Shores Village.
Remarks (Signed
STATE OF FLORIDA,
COUNTY OF DADE. j ss.
Before me, the undersigned authority, a notary public, duly authorized to administer oaths and take acknowledgments, personally ap-
peared
and who, being by me
of the above described
therein by him state
Permit No..
Disapproved
(Signed)
first duly sworn, upon oath deposes and says that he is the.
construction, that he has carefully read the foregoing application, and that he did sign the same, and that all facts
e true.
5 G ate ` t' Z 7 Read, Sworn to and Subscribed before me.
Date. ._.......
MIAMI SHORES VILLAGE
Building nspcctor
PLANNING BOARD
Date..._..__...__... Janury
— No. 4-40
Notary Public, State of Florida
ommission Expires
.DATE
Chairman Member
Member _ Member
Member ...... Member
to me well known,
Council Approved Date Disapproved Date
NOTE: A charge of $1.00 will be made for making corrections or changes to this application after approval has been obtained from
the Planning Board.
A re fee of 31.00 will be charged when such re- inspection is made necessary by improper notice for inspection or faulty
materials and /or workmanship.